combined escape route and emergency fire luminaire titania beghelli - elplast,a.s. 2010 2010...

11
Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s. 2010 2010 eghelli-Elplast has developed new luminaire Titania, which fully meet va directives for the equipping of road tunnels. 1

Upload: kelly-stanley

Post on 28-Dec-2015

227 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s. 2010 2010 Beghelli-Elplast has developed new luminaire Titania, which

Combined escape route and emergency fire luminaire Titania

BEGHELLI - ELPLAST,a.s. 20102010

Beghelli-Elplast has developed new luminaire Titania, which fully meet valid directives for the equipping of road tunnels.

1

Page 2: Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s. 2010 2010 Beghelli-Elplast has developed new luminaire Titania, which

Luminaire Titania has been developed and designed

in accordance with the

latest edition

of RABT

2

Regulations for theequipment and operation

of road tunnels

This combined escape route and emergency fire light Titania helps to show vehicle passengers

the fastest and safest way out of the tunnel in extreme cases.

Approved by German Federal Ministry for Traffic,Building and Urban Affairs

Page 3: Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s. 2010 2010 Beghelli-Elplast has developed new luminaire Titania, which

According to the German Federal Ministry of Transport

For all traffic tunnels that are longer

than 400 m must be installed with emergency fire and

escape route luminaire

Titania

3

Page 4: Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s. 2010 2010 Beghelli-Elplast has developed new luminaire Titania, which

Titania

Combined escape route and emergency fire luminaires

20 m

1,2 m

4

Page 5: Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s. 2010 2010 Beghelli-Elplast has developed new luminaire Titania, which

Titania

1. Second independent power supply from distribution network

2. Independent source of electrical energy (generate by using genset – Engine-generator, a machine used to generate electricity )and - UPS (Uninterruptible Power Supply Source, to allow time to bringan auxiliary power source on line).

The norm establishes that when a tunnel suffers from a failure of power supply, an emergency power supply system and an emergency

lighting system must be at hand.

Power supply

Operating voltage: 230V

5

Options

Page 6: Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s. 2010 2010 Beghelli-Elplast has developed new luminaire Titania, which

Titania

The body:• Stainless steel 1.4571• Dustproof and waterproof protection type IP 65• protected against water jet cleaning

Diffuser: • 4 mm safety tempered glass

Pictogram size: • 300 x 300 mm according to RABT

5 years guarantee

6

Technical features:

Page 7: Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s. 2010 2010 Beghelli-Elplast has developed new luminaire Titania, which

Titania

Special gasket for IP65

Terminal block 5x2,5mm2

Higly polishedreflector from AL

Tube clampsfor through wiring

7

Page 8: Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s. 2010 2010 Beghelli-Elplast has developed new luminaire Titania, which

Bevelled edges(to avoid injury of running people during accident)

474 mm

594 mmThickness 60 mm

Titania

Dimensions according to RABT

8

Page 9: Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s. 2010 2010 Beghelli-Elplast has developed new luminaire Titania, which

Titania

Weight 8,3 kg

Special key for opening

Safety and security

9

Page 10: Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s. 2010 2010 Beghelli-Elplast has developed new luminaire Titania, which

Titania

LED identification lights:• There is 6 LEDs Osram Golden Dragon Oval Plus inside of the housing• Luminous intensity 75cd/m2 (RABT)

LED emergency fire lights:• The internal lighting consists of 2 cool white6300K high performance LEDs. For additional security, they are linked in such a way that should one LED everfail, the others remain light.

Primary electrical circuit -14,5W

Secondary electrical circuit – 9W

All LEDs are protected behind safety glass

10

Total – 23,5W

Page 11: Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s. 2010 2010 Beghelli-Elplast has developed new luminaire Titania, which

Titania

Summary of technical data

Energy consumption: 23,5W (14,5W+9W)

Degree of protection: IP 65

Shock protection: IK09 (5 Joule)

Standards and certificatesVibration test EN 60068-2-64

Impact resistance EN 60598-1

Change of temperature Class T2 (-25°C / +55°C) IEC 60068-2-14

Damp heat Class T1/T2/T3 (+40°C) EN 60068-2-30

Water ingress Class IP65 EN 60529

Dust ingress Class IP65 EN 60529 Corrosion test (Salt spray test)

11