combined 4.06.10

Upload: angel-mayal

Post on 05-Apr-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/2/2019 Combined 4.06.10

    1/17

    BILL OF QUANTITIES (ELECTRICAL)

    LECTURE HALL & AGRIONICS DEPARTMENT

    CSIO, SECTOR - 30, CHANDIGARH

    S.NO CPWD ITEM PARTICULARS OF ITEM UNIT QUANTITY RATE

    CODE NO.

    COOPER WIRING IN STEEL CONDUIT

    1 1.3 Point wiring in steel conduit ,with modular type switch:

    Wiring for light point/fan point/exhaust fan point / callbell point with 1.5 sq.mm FR

    PVC insulated copper conductor single core cable in surface / recessed steel conduit,

    with modular switch,Modular plate ,Suitable GI box & earthing the point with 1.50

    sq.mm FR PVC insulated copper conductor single core cable etc. as required.

    1.3.3 Group c Point 50 589

    2 1.5 Power plug wiring in steel conduit (2X4 sq.mm)

    Wiring for light /power plug with 2x4sq.mm FR PVC insulated copper conductor single

    core cable in surface /recessed steel conduit along with 1 No 4 sq.mm FR PVC

    insulated copper conductor single core cable for loop earthing as required. Metre 150 136

    3 1.7 Circuit /submain wiring in steel conduit :

    Wiring for circuit /submain wiring alongwith earth wire with the following sizes of FRPVC insulated copper conductor,single core cable in surface / recessed steel conduit as

    required.

    1.7.1 2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire Metre 400 109

    1.7.3 2 X 4 sq.mm + 1 X 4 sq.mm earth wire Metre 200 135

    1.7.4 2 X 6 sq.mm + 1 X 6 sq.mm earth wire Metre 300 169

    4 1.17 Wiring in existing conduit :

    Supplying and drawing following sizes of FR PVC insulated copper coductor, single core

    cable in the existing surface / recess steel / PVC conduit as required.

    1.17.1 1 x 1.5 sq.mm Metre 300 19

    1.17.2 2 x 1.5 sq. mm + 1 x 1.5 sq.mm Metre 600 25

    1.17.3 3 x 1.5 sq.mm Metre 100 32

    1.17.11 2 x 2.5 sq. mm + 1 x 2.5 sq.mm Metre 75 321.17.13 4 x 2.5 sq.mm Metre 100 53

  • 8/2/2019 Combined 4.06.10

    2/17

    1.17.20 2 x 4 sq.mm + 1 x 4 sq.mm Metre 100 43

    1.17.29 2 x 6 sq.mm + 1 x 6 sq. mm Metre 200 59

    5 1.18 Telephone wiring in existing conduit:

    Supplying and drawing following pair , 0.5 sq.mm FR PVC insulated copper conductor ,

    unarmoured telephone cable in the existing surface / recessed PVC conduit as required.

    1.18.3 4 pair Metre 700 21

    STEEL / PVC CONDUIT ,METAL BOXES

    6 1.20. S / F steel conduit :

    Supplying and fixing of following sizes of steel conduit alongwith accessories in surface /

    recess including painting in case of surface conduit , or cutting the wall and making

    good the same in case of recessed conduit as required:

    1.20.2 25mm Metre 700 86

    1.20.3 32 mm Metre 100 105

    1.20.4 40 mm Metre 50 127

    7 1.21 S /F PVC conduit:

    Supplying and fixing of following sizes of PVC conduit alongwith accessoriesin surface /recess including cutting the wall and making good the same incase of recessed conduit

    as required:

    1.21.1 20mm Metre 200 41

    1.21.2 25mm Metre 650 47

    1.20.3 32 mm Metre 100 105

    1.20.4 40 mm Metre 50 127

    SWITCHES & ACCESSORIES

    8 1.24 S/ F modular type switch / socket :

    Supplying and fixing following modular switch/ socket on the existing modular plate and

    switch box including connections but excluding modular plate etc. as required :

    1.24.1 5/ 6 amps switch Each 75 46

    1.24.3 15/16 amps switch Each Q.R only 67

  • 8/2/2019 Combined 4.06.10

    3/17

    1.24.4 3 pins 5 / 6 amps socket outlet Each Q.R only 64

    1.24.5 6 pin 15 /16 amp socket outlet Each 52 101

    1.24.6 Telephone socket outlet Each 46 61

    1.24.7 T.v antenna socket outlet Each 1 60

    9 1.25 S / F modular type electronic fan regulator:

    Supplying and fixing stepped typed electronic fan regulator on the existing modular

    plate switch box including connections but excluding modularplate etc. as required. Each 26 247

    10 1.26 S / F modular type blanking plate :

    Supplying ang fixing modular blanking plate on the existing modular plate & switch box

    excluding modular plate as required. Each 20 20

    11 1.27 S/ F modular boxes , base & cover plate :

    Supplying and fixing following size / modules , GI box along with modularbase & cover

    plate for modular switches in recess etc. as required.

    1.27.1 1 or 2 module (75mm x 75mm)-Computer LAN & Telephone Each 58 88

    1.27.2 4 module (125 mm x 75mm) Each 6 113

    1.27.3 6 module (200 mm x 75mm) Each 1 153

    1.27.4 8 module (125 mm x 125mm) Each 2 177

    1.27.5 12 module (200mm x 150mm) -Computer supply points Each 44 225

    12 1.31 S/ F light plug point type modular type accessories :

    Supplying and fixing suitable size GI box with modular plate and cover in front

    on surface or in recess, including providing and fixing 3 pin 5/ 6 amps modular

    socket outlet and 5/6 amps modular switch , connection , painting etc. as

    required . ( For lights plugs to be used in non- residential buildings). Each 19 160

    13 1.32 S/ F power plug point modular type accessories :

    Supplying and fixing suitable size GI box with modular plate and cover in front on

    surface or in recess, including providing and fixing 6 pin 15/ 16 & 5/6 amps modular

    socket outlet and 15/ 16 amps modular switch , connection , painting etc. as required. Each 24 214

    14 1.33 S/ F ceiling rose :

  • 8/2/2019 Combined 4.06.10

    4/17

    Supplying and fixing 3 pin , 5 amp. Ceiling rose on the existing junction box/ wooden

    block including connection etc.as required. Each 15 19

    15 1.35 Erection of incandescent light fittings:

    Erection of wall bracket/ ceiling fittings of all sizes and shapes containing

    upto two GLS lamps per fitting, complete with all acccessories including

    connection etc. as required. Each 65 19

    16 1.38 S/F call bell / buzzer :

    Supplying and fixing call bell/ buzzer suitable for D.C. / A.C single phase ,230 volts

    complete as required. Each 14 26

    17 1.49 Extra down rod 20 mm dia.

    Supplying and fixing extra conduit down rod of 20cm length G.I pipe , 15 mm dia, heavy

    gauge including painting etc. as required . (Note : More than 5 cmlength shall be

    rounded to the nearest 10 cm & 5 cm or less shall be ignored. Each 18 14

    MCB,s

    18 2.52 S/F 'C' series, MCB :

    Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuitbreaker suitable for inductive load of following poles in the existing MCB DB complete

    with connections, testing and commissioning etc. as required.

    2.52.1 Single Pole Each 100 94

    19 2.54 S / F DP MCB isolator :

    Supplying and fixing following rating, double pole, 240 Volts , isolator in the existing

    MCB DB complete with connections , testing and commissioning etc. as required.

    2.54.2 63 amps Each 9 196

    20 2.57 S/F TP N RCCB :

    Supplying and fixing following rating , four pole ( three phase and

    neutral ) 415V , residual current circuit breaker ( RCCB ), having a sensitivity

    CURRENT UPTO 300 milliamps in the existing MCB DB complete with

    connections, testing and commissioning etc. as required.

  • 8/2/2019 Combined 4.06.10

    5/17

    2. 57.2 40 amps Each 2 1208

    2.57.3 63 amps(A.Cs) Each 3 1426

    21 2.62 S/F 20A SPN MCB Industrial Socket Outlet

    Supplying and fixiing 20 amps, 240 V , SPN industrial type , socket outlet with 2pole &

    earth , metal enclosed plug top along with 20amps 'c; series, SP , MCB,in sheet steel

    enclosure , on surface or in recess , with chained metal cover for the socket outlet and

    complete with connections, testing and commissioning etc. as required. Each 9 520

    EARTHING

    22 3.2 G. I earth pipe electrode with salt / charcoal:

    Earthing with G .I earth pipe 4.5 m long , 40 mm dia including accessories and providing

    masonary enclosure with cover plate having locking arrangement and watering pipe

    etc. with charcoal and salt as required. Set 8 1971

    23 3.10. S/ L 6 SWG GI in ground:

    Supplying and laying 6 SWG G. I wire at 0.50 m below ground level for conductor earth

    electrode including soldering etc.as required. Metre 200 16

    24 8.3Supplying and fixing the following sizes of Krone telephone tag blockshoused in suitablesizes of power coated MS boxes with hinge cover complete as required.

    a. 50 pair telephone tag block Each 1

    b. 20 pair telephone block Each 450

    25 10.5 Supply and drawing of cat 6 data outlet cable in existing raceway conduit as required. Metre 533

    NS ITEMS

    26 MV PANELS

    Supply, installation, testing and commissioning of powder coated

    compartmentlised cubicle MV Panel fabricated out of 14/16 SWG CRCA sheet

    steel and suitable for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply

    complete with gland plates, lifting too

    27 DISTRIBUTION BOARDS Each 4 135,0001. INCOMING FEEDER

  • 8/2/2019 Combined 4.06.10

    6/17

    a SF4 630 A, 4 pole, 50 KA with O/C, S/C Protection - with front operated rotary

    rotary handle make Schneider MG / L & T - 1 No.

    b

    MCCB 400 A, 4 pole, 50 KA with O/C, S/C Protection - with front operated rotary

    handle Make Schneider MG / L&T - 1 No.

    2. OUTGOINGS FEEDER'S

    a

    MCCB 100 Amp./50KA, with O/C, S/C protection., 3 P&N, with front operated

    rotary handle Make Schneider MG / L&T - 3 No.FSU 250 Amp. TPN with HRC fuses - 2 No.

    b

    MCCB 100 Amp./50KA, with O/C, S/C protection., 3 P&N, with front operated

    rotary handle Make Schneider MG / L&T - 1 No.

    FSU 200 Amp. TPN with HRC fuses - 1 No.

    4 way TPN 63 Amp. - 2 nos.

    5 A to 32 A SP MCBS - 48 nos.

    3. Enclosure,Bus Bar, Wiring & Accessories :

    MS Cabinet front operated compartmentalized with Base Frame fabricated from

    14/16 CRCA Sheet (make TATA Steel), Powder Coated Paint after Pre-

    treatment Process.Size : as approved drg., Protection : IP- 54; Cable Entry

    from Top / Bottom - 1 No.

    a Aluminium Busbar 600 Amp., E91 E grade Aluminium Busbar ( Current

    Insulator Neoprene Rubber Gaskets and Rubber Boots - 1 No.Hardware and Accessories, Door Hinges and Locks - 1 No.

    b

    Aluminium Busbar 400 Amp., E91 E grade Aluminium Busbar ( Current

    Density 1.0 A/Sq. mm), DMC BusBar Support Insulators, Colour Coded PVC

    Heat Shrinkable Sleeves - 1 No.

    Insulator Neoprene Rubber Gaskets and Rubber Boots - 1 No.

    Hardware and Accessories, Door Hinges and Locks - 1 No.

    28 UPS panel: Each 1 55000

    Incoming - MCCB 100 amps/ 50 KA with O/C , S/C protection with front

    operated rotary handle make Schneider MG/ L & T - 1 No.

    Outgoing - 4 Way TPN distribution board with 1 no. TPN MCB - 63 amps

    12 Nos. - SP MCB - 6 amps

    29 S. D boards Each 2 65000

    Incoming - MCCB 100 amps/ 50 KA with O/C , S/C protection with front

    operated rotary handle make Schneider MG/ L & T - 1 No.

  • 8/2/2019 Combined 4.06.10

    7/17

    Outgoing- 8Way TPN distribution board with 1 No. TPN MCB - 63 amps

    24 No. SP MCB - 6 amps each

    30 A.C panels: Each 1 55000

    Supplying, installing, testing and commissioning of outdoor type feeder

    pillar , metal clad suitable for 415 v , 3 phase 50 hz with suitable foundation

    and arrangement for incoming/ outgoing cabling / cable termination ,

    earthing , locking arrangement , insulated aluminium busbar system ,

    interconnections etc.

    Incoming unit - FSU 250 amps - 1 No.

    Outgoing unit - 4 way T.P.D.B with 12 Nos. SP MCB - 32amps

    31 Supplying ,installing, testing and commissioning in position of ceiling fan

    (a) Ceiling fan of approved make .

    1200 mm sweep Each 22 1500

    1400 mm sweep Each 3 1500

    (b) Recess mounted mirror optics lighting luminaire of size 600 x 600 mm app.

    with matt finish ribbed aluminium louvers , suitable for & including 3 Nos.

    CFL 's OF 36 W each. Each 53 4100

    (c) Downlighter W IPRO WCP 28113 /118

    1 X 13 /18 W CFL (TC- D) Each 11 1100

    ( d ) Supplying, installing, testing and commissioning of cubicle type L.T panelhaving TPN aluminium bus bar with minimum 400 amp capacity extensible

    type TPN aluminium alloy bus bars of high conductivity , DMC/SMC bus bar

    supports at required intervals complete including provision of space of

    1 no. 100 amp MCCB & 1 no. 200 amp F.S.U. Each 4

    (e)

    Dismantling/ removal of following & stacking the same as directed by employer in

    lecture hall

    (i) Dismantling of main board

    Board No. 1 ------- Main switches - 1 No.

    Bus bar - 1 No.

    T.P.D.B - 1 No.

    B.D.B - 2 No.

    Main switches - 1 No.

    Board No. 2 ------- T.P.D.B - 1 No.

    Board No. 3 ------- MCB B.D.B - 1 No.ELCB - 1 No. Job

  • 8/2/2019 Combined 4.06.10

    8/17

    (ii) Dismantling of Ceiling fan & Tube Fittings are as under.

    Ceiling Fans - 10 Nos.

    Tube Fittings - 25 Nos.

    Exhaust Fan - 3 Nos. Job

    (iii) Dismantling of Light Point , Power Point & Light Plugs are as under.

    Light Points / Fan points - 40 Nos,

    Power plug - 8 Nos.

    Light Plugs - 12 Nos.

    Industrial plugs / A.C Points - 5 Nos. Job

    (f) Dismantling / removal of following and stacking the same as directed by

    employer in agrionics department.

    (i) Ceiling Fan - 4 Nos.

    (ii)Tube Fittings - 10 Nos.

    (iii) Exhaust Fan - 2 Nos.

    (iv) Light Point / Fan point - 25 Nos.

    (v) Power Plugs - 3 Nos.

    (vi) Light Plugs - 4 Nos. Job

    32 Providing & fixing push ON/ OFF type- 400 W white colour dimmer for light

    controls, over existing modular plate . Each 8 875

    33 Providing & fixing M.S hanger / chains to hang the luminaires from RCC slab. Metre 50 30

    34 Providing & fixing in position G.I B' class pipe , down rod of 20mm dia.

    including cutting and threading etc.complete for ceiling fans. Metre 10 300

    35 Supplying , installing , testing and commissioning of aluminium armoured

    cable of size 3.50 core - 50 sq.mm over surface / ceiling including 2 No.s

    8 SGW G.I wire complete. Metre 120 500

    TOTAL :

    (RUPEES)

  • 8/2/2019 Combined 4.06.10

    9/17

    EMPLOYER ARCHITECT CONTRACTOR

  • 8/2/2019 Combined 4.06.10

    10/17

    S.NO CPWD ITEM PARTICULARS OF ITEM

    SANITARY INSTALLATIONS

    32 17.7 Providing and fixing wash basin with C.I. brackets , 15mm C.P. brass pillar taps,

    32mm C.P. brass waste of standard pattern , including painting of fittings

    and brackets , cutting and making good the walls wherever require:

    17.7.2 White vitreous china wash basin size 630 x 450mm with a single 15 mm C.P.

    brass pillar tap.

    33 17.8 Providing and fixing white vitreous china pedastal for wash basin completely

    recessed at the back for the reception of pipes and fittings.

    34 17.1 Providing and fixing stainless steel A ISI 304 (18/ 8) kitchen sink as per IS 13983

    with C.I brackets and stainless steel plug 40 mm including painting of fittings

    and brackets , cutting and making good the walls wherever require:

    17.10.1.3 510 x 1040mm bowl depth 200mm

    35 17.28 Providing and fixing PVC waste pipe for sink or wash basin including PVC

    waste fittings complete.

    17.28.1.2 40 mm dia.

    36 17.32 Providing and fixing mirror of superior glass ( of approved quality)and of

    required shape and size with plastic moulded frame of approved make andshade with 6mm thick hard board baking:

    17. 32.2 Rectangular shape 453 x 357mm

    37 17.35 Providing and fixing soil , waste and vent pipes:

    17.35.1.1 Sand cast iron S & S pipe as per IS : 1729 .

    17.35.2.1 Sand cast iron S & S pipe as per IS : 1729 .

    38 17.36 Providing and filling and joints with spun yarn cement slurry and cement

    mortar 1 :2 ( 1 cement :2 fine and ) in S.C.I/ C.I. PIPES:

    17.36.1 75 mm dia. Pipe

    17.36.2 100 mm dia. Pipe

    39 17.57 Providing and fixing collar :

    17.57.1 100mm

    17.57.1.2 sand cast iron S&S as per I.S -1729

    17.57.2 75mm

    17.57.2.1 sand cast iron S&S as per I.S -1729

  • 8/2/2019 Combined 4.06.10

    11/17

    40 17.61 Cutting chases in brick masonary walls for following diameter sand cast iron/

    centrifugally cast (spun ) iron pipes and making good the same with cement

    concrete 1:3:6 ( 1 cement:3 coarse sand:6 graded stone aggregate 12.5 mm

    nominal size)including necessary plaster and pointing in cement mortar 1:4

    (1cement : 4 coares sand ) :

    17.61.3 50 mm dia.

    41 17.69 Providing and fixing PTMT waste coupling for wash basin and sink , of

    approved quality and color.

    17. 69.2 waste coupling 38mm of 83 mm length and 77 mm breadth , weighing not less

    then 60 gms.

    42 17.70. Providing and fixing PTMT bottle trap for wash basin and sink.

    17.70.2 Bottle trap 38mm single piece moulded with height of 270 mm , effective

    length of tail pipe 260mm from the centre of the waste coupling 77mm

    breadth

    breadth with 25mm minimum water seal , weighing not less then 263gms.

    43 17.71 Providing and fixing PTMT liquid soap container 109mm wide , 125 mm high

    and 112 mm distance from wall of standard shape with bracket of the same

    materials with snap fittings of approved quality and color. Weighing not less

    then 105gms.

    44 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215mm long , 200mm

    wide with a minimum distances of 37mm from wall face with concealed

    fittings arrangement of approved quality and color. Weighing not less then 88

    gms

    WATER SUPPLY

    45 18.11 Concealed pipe including painting with anti corrosive bitumastic paint,

    cutting chases and making good the wall.

    18. 11. 1 15mm dia. Nominal bore

    18.11.2 20mm dia. Nominal bore

  • 8/2/2019 Combined 4.06.10

    12/17

    46 18. 13 Making connection of G.I distribution branch with G.I main of following sizes

    by providing ang fixing tee, including and cutting and threading the pipe etc.

    complete.

    18.13.1 25 to 40 mm nominal bore

    47 18.18 Providing and fixing valve ( brass)of approved quality , high or low pressure ,

    with plastic floats complete:

    18.18.2 20mm nominal bore

    48 18.21 Providing and fixing uplaticised PVC connection pipe with brass unions:

    18.21.1 30cm length

    49 18.40. Painting G.I pipes and fittings with two coats of anti -corrosive

    Bitumastic paint of approved quality:

    18.40.1 15 mm dia.m Pipe

    18.40.2 20 mm dia.m Pipe

    50 18.47 Providing and fixing G.I union in existing G.I pipe line , cutting and threading

    the pipe and making long screws including excavation , refilling the earth or

    cutting of wall and making good the same complete wherever required:18.47.3 25mm nominal bore

    51 18.53 providing and fixing C.P brass angle and valve for basin mixer and geyser

    points of approved quality confirming to IS :8931 a) 15 mm nominal bore

    18.53.1 15 mm nominal bore

    DRAINAGE

    52 19.4 Providing and fixing square -mouth S.W . Gully trap grade 'A' comlete with

    C.I. grating brick masonry chamber with water tight C.I. cover with frame of

    300 x 300 mm size (inside) the weight of cover to be not less then 4.50 kg and

    frame to be not less than 2.70kg as per standard design:

    19.4.1.1 with F.P.S bricks class destination 75

  • 8/2/2019 Combined 4.06.10

    13/17

    53 19.7 Constructing brick masnory manhole in cement mortar 1:4 ( 1 cement :4 coarse

    sand ) R.C.C. top slab with 1:2:4 mix ( 1 cement :2 coarse sand :4 graded stone

    aggregate 20 mm nominal size) , foundation concrete 1:4:8 mix ( 1 cement : 4

    coarse sand :8 graded stone aggregate 40 mm nominal size ) inside plastering

    12 mm thick with cement mortar 1:3 ( 1cement :3 coarse sand) finished with

    floating coat of neat cement and making channels in cement concrete 1:2:4

    ( 1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

    finished with a floating coat of neat cement complete as per standard design:

    19.71.1.1 With F.P.S bricks with class designation 72

    54 19.21 Making connection of drain or sewer line with existing manhole including

    breaking into and making good the walls , floors with cement concrete 1:2:4

    mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size )

    cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse

    sand ) finished with a floating coat of neat cement and making necessarychannels for the drain etc. complete :

    19.21.1 For pipes 100 to 230 mm diameter

  • 8/2/2019 Combined 4.06.10

    14/17

    UNIT QUANTITY RATE AMOUNT CONT.SIGN.

    Each 1201.7

    Each 705.9

    Each 5225.15

    Each 47.95

    Each 465.1

    Metre 451

    Metre 395.45

    Each 25.3

    Each 29.8

    Each 143.45

    Each 202.7

    Each

    Each 107.8

  • 8/2/2019 Combined 4.06.10

    15/17

    Metre 68.4

    Each 100.2

    Each 395.25

    Each 164.65

    Each 149

    Metre 144.75

    Metre 170.15

  • 8/2/2019 Combined 4.06.10

    16/17

    Each 166.05

    Each 333.25

    Each 35.1

    Metre 2.6

    Metre 3.05

    Each 180.55

    Each 347.65

    Each 935.15

  • 8/2/2019 Combined 4.06.10

    17/17

    Each 5383.7

    Each 164.3 `