colector solar interesant
TRANSCRIPT
-
8/8/2019 Colector Solar Interesant
1/2
INTEGRALCOLLECTORSTORAGESYSTEM
SPECIFICATIONSHEE
PROTECTING OUR ENVIRONMENTSINCE 1978
EPDM Grommets
Moderately SelectiveAbsorber Coating
Seamless CopperStorage Cylinders
Secondary SiliconeGlazing Seal
Primary EPDM
Glazing Seal
Low Iron
Tempered Glass
Riveted Corners
15% Silver Brazed
Manifolds
Rigid Foam Insulation
Extruded AnodizedAluminum Casingand Capstrip
Stainless Steel
Fasteners
SIMPLE, DURABLE, AND RELIABLEThe CopperHeart Integral Collector Storage System
IntegralMounting
Channel
THE COPPERHEART SERIESOPPERHEART
Aluminum Backsheet
-
8/8/2019 Colector Solar Interesant
2/2
ENGINEERING SPECIFICATIONS
COPPERHEARTICSSPECIFICATIONS
(Performance specifications subject to testing error of +/- 3%)
The solar water heating system shall be of the integral collector stor-age (ICS) type, and shall require no pumps, controls, or parasiticenergy consumption for its normal operation. The ICSunit shall bethe SunEarth CopperHeart ICSmodel number _____________. TheCopperHeart ICS unit shall be tested in conformance w ith SRCCStandard OG-200 by an independent testing laboratory, certifiedby the SRCC under system standard OG-300, and also by theFlorida Solar Energy Center (FSEC).
GENERALThe dimensions of the CopperHeart ICS model number
________________shall be________inches in length, 36 1/ 2 inchesin width, and 6 7/8 inches total depth to the top of the glazing cap-strip, and be rated at a nominal capacity of
__________________U.S. gallons. The casing shall be an anodizedaluminum extrusion (alloy 6063 T5), a minimum 1/ 8 inch in thick-ness, with an architectural dark bronze finish. Sheet metal fasten-ers shall be stainless steel (18-8 #10 X 1/2). The framewall shall besecured by four exterior anodized aluminum corner bracketsattached w ith 8 each AD54BSaluminum rivets per corner. The cas-ing backsheet shall be textured aluminum of not less than .014inches in thickness.
GLAZINGThe glazing shall be one sheet of low iron tempered glass of notless than 1/ 8 inch th ickness, and have a minimum transmissivity of91%. The glazing shall be thermally isolated from the casing by acontinuous EPDM gasket. There shall be a secondary silicone seal
between the glass and the aluminum capstrip to minimize the intrusion of moisture into the casing.
INSULATION
The backing insulation shall be a foil-faced polyisocyanurate foamsheathing board w ith a minimum thickness of 1 1/ 2 inches, andshall be siliconed in place to the aluminum backsheet. Aged ther-mal resistance R-value of the backing and side-wall insulation shalbe not less than R-12 at 75F mean temperature. The ends of the
ICSshall be insulated with 1 inch polyisocyanurate foam sheathingboard with an aged thermal resistance R-Value of no less than 7.2.
ABSORBER/STORAGE CYLINDERS
The CopperHeart ICSshall combine the collector and storage tankas one unit. The all copper storage cylinders shall be seamlessdrawn 4.125 inch O.D. copper tubing with a minimum wall thickness of .058 inches, and have machine spun ends to accept 7/ 8inch O.D. Type L copper internal manifolds. Eight storage cylindersshall be manifolded in series to form a storage vessel. The ratedinternal working pressure shall be 120 PSIG at 200F.All internal manifold braze joints shall be joined utilizing a copperphosphorous brazing alloy w ith no less than 15% silver content andconforming to the American Welding Societys BCuP-5 classification
EPDM grommets shall isolate the manifolds from the aluminum casing.
ABSORBER COATING
The absorber coating shall be a moderately selective paint with aminimum absorptivity of 94 percent and a maximum emissivity of56 percent.
Due to SunEarths policy of continuous product improvement, specifications are subject to change without notice.
4315 Santa Ana St. Ontario, CA 91761
(909) 605-5610 Fax (909) 605-5613
MANUFACTURED BY: AVAILABLEFROM:
VA
LENT
I BROT
HERSGRAPH
ICS
FULL
SERVICE PRIN
TER
S
CP-20
CP-30
CP-40
29
29
29
120
120
120
Inle
ttoO
utle
t
Cent
erto
Cen
ter,
Inch
es
SunE
arth
Mod
elN
o.
Inle
tand
Outle
t
Pipi
ng,I
nche
s
3/4
3/4
3/4
Rate
dIn
tern
al
Worki
ngP
ress
ure
@20
0Fin
PSI
G
* For systems where two individual CopperHeart ICS units are required or preferred, the model numbers are CP-40-2 (two CP-20), CP-60 (tw o CP-30), and CP-80 (tw o CP-40).
THERMAL PERFORMANCE RATINGS*
* Performance results are for the Solar Rating and Certification Corporation (SRCC) rating day and are derived from TRNSYSsimulation in conjunction with SRCC OG-200 system test results. OG-200 tests were independently conducted by DSETLaboratories, Inc. Phoenix, AZ.
Model CLEAR DAY2000 Btu/ ft2/Day
MILDLY CLOUDY DAY1500 Btu/ft2/Day
CLOUDY DAY1000 Btu/ ft2/Day
CP-20
CP-30
CP-40
18,675
31,730
35,810
11,900
21,690
24,750
9,940
16,465
18,505
20
32
40
Flui
dCa
pacity
U.S
.Gallo
ns
321
477
597
Wet
Wei
ght,
Lbs.
154
210
264
Dry
Wei
ght,
Lbs.
36 1/2
36 1/2
36 1/2
50 1/4
78 1/4
98 1/4
6 7/8
6 7/8
6 7/8
13.90
21.10
24.60
10.90
17.40
21.91
Wid
th
Inch
es
Leng
th
Inch
es
Dep
th
Inch
es
Gro
ssAr
ea
SqF
t
Net
Ape
rture
SqF
t
Btu/Day/Unit Output
R EC Y C L E D PA P E R S O Y B A S E D I N K
www.sunearthinc.com