CMS Radioactive Source Driver SystemsStatus and Action Items
Paul Debbins
University of Iowa
October 14, 2005
![Page 2: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/2.jpg)
Table of Contents
• Status of Electric Drivers– Modifications Implemented
– Delivery Schedules
– Ongoing Work
• Evaluation/Recommendations for Air Drivers– HE type– HB type
![Page 3: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/3.jpg)
Electric Diver – Modifications Implemented
• Source Wire Reel and Wire Support system– Source Wire Reel. Reel is mounted on captive roller bearings. Provides stable
low-friction operation of reel. Allows monitoring of drive motor current to serve as a useful diagnostic tool of system health. Reel manufactured of MDS Nylon for low friction and excellent abrasion resistance.
– Lower Support Wire/Spring fingers. Provide even support underneath source wire. Eliminate escape holes in reel base plate. Isolate source wire from seam between reel and reel base plate.
– This set of modifications work together to prevent the most serious form of driver failure: source wire ejection and destruction. Testing so far is promising, but more is needed, particularly regarding wear of the lower support wire.
![Page 4: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/4.jpg)
Electric Diver – Modifications Implemented
• General Mechanical Modifications
– A variety of mechanical improvements were implemented to enhance the overall long-term reliability of the units. Some examples are:
• Elimination of unnecessary mechanical linkages and adjustment points
• Spring Centering mechanism on reel end-stop mechanism
• Guard plates for sensitive mechanisms
![Page 5: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/5.jpg)
Electric Driver Delivery
• 2 Modified Drivers delivered to CERN; Icarus01, Icarus02– Icarus01 currently sourcing HE-
– Icarus02 currently sourcing HB+
• 2 more drivers to ship Nov.1; Icarus03, Icarus04– Icarus03 to be used in HF fingerprinting
– Icarus04 as spare on site
• More Drivers are in shipment to Iowa to receive modifications
![Page 6: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/6.jpg)
Electric Drivers – Ongoing Work
• HE/HB/HF fingerprinting in Fall 2005 constitutes an extensive ‘on site’ testing phase of the modified drivers.
• After fingerprinting drivers should be torn down and evaluated.– Identify wear and establish normal service interval and procedures
– Identify any further mechanical refinements needed
• Continue to develop support infrastructure– Spare parts, tools, documentation
![Page 7: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/7.jpg)
HE type Air Driver
![Page 8: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/8.jpg)
Air Drivers - General
• Air drivers are quite different from electric drivers
• Some Electric Driver improvements directly extend to Air devices– Reel System, adaptations for non-magnetic bearing and vert. clearance
– Lower support wire and spring finger system
• Pneumatic Drive, Indexer, and mechanical layout are very different– There are immediately apparent improvements
• Replace plastic air lines with copper and more permanent connectors
• Mount loose components solidly
• Tie down wiring
• Reel end stop centering system
![Page 9: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/9.jpg)
Air Drivers - General
• Other refinements will require more experience with the driver
– Air Drivers have very different operational behaviors.• Air motor torque/speed
• Pecking behavior
• How to monitor reel/wire friction and forces?
– Long Term testing needed to flush out potential problems
• Long term testing in Magnetic Field
![Page 10: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/10.jpg)
• Deliver one HE and one HB type driver for Magnet Test– Time only to implement core improvements
• Reel/Support Wire system
• Secure loose components
• Stronger pneumatic system
– HE driver delivered to CERN Dec 5,2005
– HB driver to CERN no later than Feb. 1, 2006
• Exercise Drivers in B field
• Continue to study driver behaviors with units in workshop
• After Mag. Test incorporate additional refinements
Air Drivers – Action Plans
![Page 11: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/11.jpg)
Air Drivers - Misc
• Iowa Currently has 1 HE driver– 3 more in shipment to Iowa, sufficient for current needs
• 2 HB drivers are needed at Iowa– 1 outfitted for mag. Test
– 2 remains at Iowa for testing
![Page 12: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/12.jpg)
![Page 13: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/13.jpg)
![Page 14: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/14.jpg)
![Page 15: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/15.jpg)
![Page 16: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/16.jpg)
![Page 17: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/17.jpg)
![Page 18: CMS Radioactive Source Driver Systems Status and Action Items Paul Debbins University of Iowa October 14, 2005](https://reader035.vdocuments.mx/reader035/viewer/2022062321/56649e555503460f94b4cc26/html5/thumbnails/18.jpg)