SMART BASIC METERS/
TRANSDUCERS/DC ENERGY
BASIC
www.elmeasure.com
BASIC PARAMETERS
MEASURED PRECISELY!
Intertek4007051
CM
Contact for certification details
Ammeter | Voltmeter | VAF Meter | Hz Meter | Frequency Meter | DC Meter | RPM & MPM
www.powercorporation.in
Common Features :
True RMS.
Four digit resolution with auto scaling.
Field programmable Star (Wye) or Delta or Single
Phase configuration.
Average & Phase wise information.
Additional Features:
Universal auxiliary input 80 - 300V AC
(Optional: 40-300V DC, 80-300V AC/DC).
Auto-scrolling.
Available in single row Dinrail version (Alpha+D
VAF, Alpha+D V/3V, Alpha+D A/3A, Alpha+D Hz).
Minimum order quantity apply.
Optional direct measurement upto 20A.
60A or 100A max. using Hanging CT.
Available in 0.8 inch display (4 digit) - optional
(for Alpha+ series only). Minimum order quantity
apply.
Optional Features :
2 digital output programmable for threshold upto
6 parameters (Under/Over).
Programmable tripping time upto 180 secs. with
Hysteresis of 1%.
Analog transducer output 0-20mA / 4-20mA or 0-
1V, Accuracy of 1% FS (Alpha+ only).
Optically isolated RS 485 / RS 232 serial interface
(Alpha+ only).
Displays more than 13 basic parameters i.e., VLL,
VLN, A (Average & Phase wise), F, ON Hours.
Programmable Relay Output (upto 2) {VLL, A, F
(under, over)}.
Displays Line to Line Voltage -Average and phase
wise, Amps - Average and phase wise & Frequency
(External selector switch to be used for µAlpha+
VAF).
Field programmable PT and CT primary and
secondary.
Optional programmable relay output (upto 2) for
any threshold VLL avg, A, Hz (under or over).
Optional transducer output
(0 to 20mA / 4 to 20mA or 0 to 1V DC)
for average VLL, VLN, Amps and F
(for Alpha+ series only) Accuracy 1% FS.
OMEGA 1300
Displays Amps for Alpha+ A and Amps (Avg & PW)
for Alpha+ 3A.
Field programmable CT primary and secondary.
Models: Alpha+ 3A & µAlpha+ 3A (3 Phase); Alpha+
A & µAlpha+ A (single phase).
Optional programmable relay output (upto 2) for
threshold Amp (under or over).
Optional transducer output (0 to 20mA / 4 to 20mA
or 0 to 1V DC) for average Amps (for Alpha+ series
only) Accuracy 1% of FS.
+ + ALPHA VAF/3VAF, µA VAF
+ +ALPHA / µA Hz
Displays wider range of frequency 40 - 70 Hz.
Higher accuracy class 0.2.
Optional programmable relay output (upto 2) for
threshold Hz (under or over).
Optional transducer output (0 to 20mA / 4 to 20mA
or 0 to 1V DC) for Hz(Range 45 to 65Hz) (for Alpha+
series only)
Accuracy 1% of FS
Displays VLL, VLN (Avg & PW), F, for Alpha+ 3V
& µA+ 3V. VLL for Alpha+ V & µA+ V
Field programmable PT primary and
secondary.
Models: Alpha+ 3V & µAlpha+ 3V (3 phase
measurement); Alpha+ V & µAlpha+ V (Single
Phase).
Optional programmable Relay output (upto 2)
for any threshold VLL, Hz (under or over) for
A+3V & only VLN (under or over ) for A+ V.
Optional transducer output (0 to 20mA / 4 to
20mA or 0 to 1V DC) for Average VLL, VLN and
F (for Alpha+ series only) Accuracy 1% of FS.
DC Vin - 75mV or 100mV or 10V or 100V or
500V.
0-20 mA / 4-20 mA input options. 4 digit
resolution for ADC.
DC auxiliary from 80-300V option available for
Alpha+ and Dinrail version.
Field programmable full scale or offset value.
DC Vin - 75mV or 100mV or 10V or 100V or
500V.
0-20 mA / 4-20 mA input options. 4 digit
resolution for RPM.
DC auxiliary supply option of 40 to 300V
available.
Field programmable full scale or offset value.
+ +ALPHA / µA 3V/V
+ +ALPHA / µA ADC/VDC
+ +ALPHA / µA RPM/MPM
+ +ALPHA / µA 3A/A
AMMETER VOLT METER
VAF METER
DC METER
Hz METERRPM/MPM METER
VAF METER
Technical Specification :
ECO Friendly Lead Free 18 Months Warranty
Transducer Output Programmable :
Note: Additional error of 0.05% of full scale, for meter input current below 500mA
ALPHA+, µA+ & OMEGA
Accuracy:
Sensing/Measurement:
Input voltage:
A
Transducer
Models
Alpha+ 3VAF
Sl
No
1
Any One Output
Programmable
Output Range
Options
V A Hz W VA PF
Alpha+ 3V2
Alpha+ 3A3
Alpha+ Hz4
LG+ 51105
V A Hz
V Hz
Hz
V A Hz W VA PF
0-20mA / 4-20mA
0-1V DC
0-20mA / 4-20mA
0-1V DC
0-20mA / 4-20mA
0-1V DC
0-20mA / 4-20mA
0-1V DC
0-5V DC
0-10V DC
0-20mA / 4-20mA
0-1V DC
A
TRANSDUCER OUTPUT
E l M e a s u r e t r a n s d u c e r s a r e
programmable transducers (cum display),
which converts various applicable
electrical parameters like voltage, current,
frequency, active power, apparent power,
power factor into DC current 0-20mA or 4-
20mA (Programmable) or voltage 0-1V DC
output.
Applications are various: electrical,
chemical, thermal power plants, etc., to
monitor processed data either locally or
remotely using scada system by
ElMeasure or the third party.
Accuracy : Class 1.0FS
Maximum overload: 120% (Equivalent of
24mA)
Number of output: One (0 to 20mA / 4
to 20mA or 0-1V DC)
Features & Benefits :
Programmable primary / secondary voltage or
current making wider range of operations
- Stocking becomes simple
Programmable transducer output either 0-20mA
or 4-20mA. (Maximum load resistance: 75ohms.)
0-1V DC optional
DC current signal or DC voltage signal directly
proportional to the change of input.
Fully protected against open and short circuited
output.
OM 1300
OM1310
ALPHA+ 3VAF
ALPHA+ VAF µALPHA+ VAF
ALPHA+ 3A µALPHA+ 3A
ALPHA+ 3V µALPHA+ 3V
ALPHA+ A µALPHA+ A
ALPHA+ V µALPHA+ V
ALPHA+ ADC µALPHA+ ADC
ALPHA+ VDC µALPHA+ VDC
ALPHA+ Hz µALPHA+ Hz
ALPHA+ RPM µALPHA+ RPM
96×96×50mm 96×48×45mm
* Dinrail available as per minimum order quantity basis.
VLL, VLN, AMP, Hz, ON Hrs.
VLL, VLN, AMP, Hz,PF, ON Hrs, Hi Amps,RPM.
VLL, VLN, AMP, Hz
VLN, AMP, Hz (Single Phase)
AMP-Avg, AR, AY, AB
VLL, VLN, Avg & Phase wise, Hz
AMP A
VOLT V
AMP DC
VOLTS DC
Frequency (Hz)
RPM
Transducer Parameters
Product Selection :
Dinrail* (90 × 90 × 50mm)
Note : DC measurement Accuracy Class 1.0FS, Class 0.5FS (optional)
In Dinrall version other than RS458, no other option is possible
Specification Description
Class 1 Default ,Class 0.5, 0.5S as per IEC 62053-22as per IEC 62053-21
True RMS, 1 Sec update time.
4 Voltage inputs (VR, VY, VB, VN); Programmable 110 or 415V LL Nominal
(Range 80-550V LL); Primary Programmable up to 999 kV.
Burden: 0.2VA Max. per phase
Current inputs (AR, AY, AB) 50mA - 6A (Field configurable 1A or 5A).
Primary Programmable up to 99 kA.
Overload: 10A max continuous, 50A max for 3 Sec
Burden: 0.2VA Max. per phase.
80 - 300V AC for Omega 80-300V AC/DC, 40-70Hz
Burden: 4VA Max
4digits display with 14 mm height for Alpha Plus, 10 mm height for OMEGA
series, µAlpha Plus series & DinRail
RS485 serial channel connection, Industry standard Modbus RTU protocol
(RS232 optional). Zigbee communication.
Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps)
Isolation: 2000 Volts AC isolation for 1 minute between communication and
other circuits.
Unpacked: 300 gms, Packed: 400 gms
Input Current
Display:
Communication:
Weight:
Aux-Supply(Control Power):
Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters
| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input
Output | Transducers | Converters
Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE
HO & Unit-I:
Plot No.: 47-P, Hardware Park, KIADB,
Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,
Bengaluru - 562149 Karnataka INDIA.
Unit-II:
Goutham Garden, No. 4, Veerapandi,
Coimbatore - 641019 Tamilnadu INDIA
T: 0422 2697200 TF: 0244 2695200
Unit-III:
#764, 4th Phase, 707, Yelahanka New Town,
Bengaluru - 560 064 Karnataka INDIA
T: +91 80 28461744
ELMEASURE INDIA PRIVATE LIMITED
Mechanical Specification:
Safety: Designed to meet protection class III, pollution degree 2.
Protection against shock by double insulation.
Clearance and creepage meets as per UL 61010 safety standard.
Finger touch proof terminals to voltage and current connections
Environment:
Operating temperature -10°C to +55°C (14°F to 131°F)
Storage temperature -25°C to +70°C (-13°F to 158°F)
Humidity 5% to 95% non condensing.
Protection index IP 51 (IP 54 front option).
Recommended wire gauge 12 to 14 SWG.
Safety and Environmental Specification
Applicable Standards : Dimension Bezel:
96 x 96 mm (Depth 50mm behind Bezel)
96 × 48 mm (Depth 45mm behind Bezel)
Panel Cutout:+2 +290 x 90 mm-0 -0 +2 +290 x 42 mm-0 -0
PC
/AP
O/V
9/1
01
7
DIN 40050
EN 60529
Degrees of protection provided by enclosure for electrical
equipment against ingress of solid foreign objects.
DIN /
IEC 688-1
Electrical measuring transducers for converting AC electrical
quantities into DC electrical quantities.
IS 12784 Electrical measuring transducers for converting AC electrical
quantities into DC electrical quantities.
Additional features for EDC 1100
Displays V, 1 channel current, 1 channel Watt and
1 channel energy in the bright single row 6 digits.
Optional RS485 communication.
Optional single digital output with the programmable delay.
Additional features for EDC 4100
Displays V, 4 channels Current, 4 channel Watts and energy in
the bright single row 6 digits.
Optional RS485 communication.
Optional single digital output with the programmable delay.
Additional features for EDC 4400
Displays V, 4 channels Current, Watts and Energy.
Optional Load Hours (LH) and Amps hours (Ah).
Optional RS485 communication.
Optional two digital output with the programmable delay.
Additional features for EDC 4100D
LCD display, 7 digit, Din rail version only
Hall effect CT (100A) Option
ECO Friendly Lead Free 18 Months Warranty
Technical Specification :
Class 1.0 FS, Class 0.5 FS (optional)
4Row 6Digits for EDC4400, 1Row 6Digits for EDC4100 and
EDC1100.
One Input Voltage (48VDC Factory Default). Varieties of
range in Voltage like 48VDC, 100VDC, 150VDC,
300VDC,600VDC, 800VDC (factory settable). Primary
Programmable range: 0.100 to 999.9kV .
45 - 65 Hz
One/ Four Input Current (50mV, 75mV Shunt type).
Individually Programmable primary current. Range: 0.100
999.9k .
80 - 300V AC/DC, 40-70Hz
Burden: 4VA Nominal.
Rs485 interface Industry Standard Modbus RTU protocol
(RS232 optional).
4800 bps to 19200 bps. (Preferred 9600 bps).
2000 volts AC isolation for 1 minute between
communication and other circuits.
(Approx): Unpacked - 300 gms, Shipping - 400 gms.o o o o-10 C to +55 C (14 F to 131 F).o o o o-25 C to +75 C (-13 F to 581 F).
5% to 95% non condensing.
IP 51 (IP 54 front option).
12 to 14 SWG.
EDC
MULTI CHANNEL DC ENERGY METER
Common Features :
Single meter measures Multiple channels and True RMS measurements.
Differential current input for all the current channels.
Voltage Full scale programmable.
Current full scale programmable independently.
Reverse lock option for not accumulating the reverse current energy. This can be
used for the better study of charging and discharging circuit.
Programmable shunt secondary 50mV to 75mV.
Energy display programmable-counter based or resolution based.
Energy resetting at 999999*PT.Pri*CT Pri.
Auto scaling of kilo and mega decimal point.
Optional programmable relay output maximum 2 (upto 6 threshold parameters)
and tripping time upto 180 seconds.
Specifica�on Descrip�on
Accuracy:
Communication:
Baud rate:
Isolation:
Weight: OperatingTemperature:
StorageTemperature: Humidity:
Protection index:
Display Resolution:
Input voltage:
Input current:
Aux-Supply:
Recommended
connection wire:
92mm
44
mm
90 mm
90 m
m
Panel
Clamp
Panel Cutout
Input Frequency:
DIGITAL MULTIFUNCTION
LOAD MANAGER
LGP & MGP
SIMULTANEOUS MEASUREMENT
OF VARIOUS ELECTRICAL
PARAMETERS!
Intertek4007051
CM
Contact for certification details
www.elmeasure.com
Basic | Power | Energy | Load Manager | Digital Output | Pulse Output
www.powercorporation.in
Features :
Accuracy Class 1.0 (default) as per IEC 62053-21,
Class 0.5 as per IEC 62053-22 (Optional).
True RMS measurement.
Simultaneous sampling of Volts & Amps.
Energy display programmable-counter based or
resolution based.
Energy resetting at 999999 kVAh* Transformer
Ratio
Positive energy accumulation even with CT
polarity reversal, reverse lock programmable.
User programmable password protection.
Auto scrolling.
Auto-scaling of Kilo, Mega, Giga and Decimal
point.
Low PT, CT burden.
Front LED pulse 1250 imp/kWh of secondary
input.
Programmable PT, CT ratio upto 2000 MVA.
Programmable kVAh (default kWh) for meters
with Energy parameter.
Wide Measurement range - 10mA - 6A.
Clearance and Creepage distance meets safety
standard.
Finger touch proof terminals to voltage and
current connections.
Parameter name & value displaying using 7 seg
LEDs.
6 digits display on each row for better readability.
Available in LED (3 row, 2 row and 1 row), LCD,
Dinrail (1 row).
Field programmable Star (Wye) or Delta or Single
phase configuration.
Optional Features :
Communication with PCs, PLCs, DCS through optional optically isolated RS 485/ RS 232 serial Interface.
Pulse output - programmable pulse width of 50 mS to 500 mS (for LG plus models only).
Programmable Relay output - refer Product Selection Table.
+LG 3399
Displays PF, Wh or VAh (programmable), OLD and
user selectable parameters from Basic (VLL, VLN, A,
Hz) or W or VA (any 2).
Displays more than 15 parameters.
3 row LED display with 6 digits each.
‘OLD' register to store the previously cleared
energy value.
Note: No up-gradations and no optional features
except RS 485
+LG 5310
Quick and Easy navigation and programming.
Displays more than 25 parameters Basic, Power and
Energy.
Basic : VLL, VLn, A, (Avg. & PW), F, RPM.
Power : W, PF, VA, (Avg. & PW)
Energy : Wh, Hi. Amps, LH, OLD Wh, OLD LH, ON
Time (non resettable).
OLD register to store the previously cleared energy
value and its corresponding LH.
Optional - Programmable relay output (upto 2) for
any threshold of Under & Over ( Voltage, Amps,
Frequency), Under PF, Over Watts, Over Wh, Phase
missing.
Programmable tripping time up to 180 sec. with
hysteresis of 1%.
+ +LG 1129 /LCD, µG 1129
+LG series has optional optically isolated RS485 or pulse output, which can be integrated into a
process through a PLC/DCS for online energy management
For pulse output, if the DCS/PCS has a self excited 12V or 24V, external 24V DC supply is not required.
+LG 5110 µG/Dinrail/LCD
+ +LG 1119 /LCD, µG 1119
Field programmable W or VA or PF or Wh (any
one parameter). Factory configured : Wh.
Displays programmed parameter name and
value for instantaneous parameters.
Reduces complexity of stocking as this can be
used for multiple measurement applications.
OLD register to store the previously cleared
energy value.
Note: Also available in dinrail version
Field programmable to Basic (VLL, VLN, A, F) or W or
VA or PF or Wh (any two parameters). Factory
configured : Wh, PF.
Displays programmed parameter name and value
for instantaneous parameters.
Reduces complexity of stocking as this can be used
for multiple measurement applications.
OLD register to store the previously cleared energy
value.
R
V - A - Hz
Y B Hz
K
A 3VAF+
VLL VLN A
ALPHA+PRG
ALPHA+
PRG
MINUS
AMPS DC
K
A ADC+
Wh
LG 1 1 19+
LITTLE GENIUS+
PRG
OLDREV
W
VA
PF
VAF
Application Information:
Displays Basic : VLL, VLn, A (Avg. & PW), F.
Power: W, PF,VA (Avg. & PW). Energy : Wh, LH,
Old Wh, Old LH.
Energy is programmable to Wh or VAh with 7
digit resolution (LCD), 6 digit resolution (LED)
and 4 digit resolution for instantaneous
parameters.
OLD register to store the previously cleared
energy value and its corresponding LH.
80 to 300 V AC/DC auxiliary supply.
Optional - Programmable relay output (upto
2 in LCD version and 1 in LG+ 5110) for any
threshold of Under & Over(Voltage, Amps,
Frequency), Under PF, Over Watts, Over Wh,
Phase missing.
Programmable tripping time upto 180 sec
with hysteresis of 1%.
Energy Reset : 999999 kVAh × Transformer Ratio.
0.4kto
4.0k
0.01
4.01kto
40k
0.1
40.1kto
400k
1.0
400.1kto
4,000k
10
4 Mto
40 M
100
40 Mto
400 M
1000 10000
400 Mto
4000 M
KWH MWH GWH
Multiplication Factor:
Full Scale Watts
3 V Pri LL x A Pri
Unit of display
Multiplication factor for counter based energy mode:
DUAL SOURCE ENERGY METER
+ + +LG 5220 / LG 3220 / LG 5120L
MON FEATURES
Automatic switching of display based on input
source (EB/DG).
Load hours and ON hours for both sources.
Positive energy accumulation / reverse lock
programmable.
Programmable to kWh or kVAh.
‘OLD' registers to store the previously cleared
energy values.
Additional Features: LG 5220
2 Row display with 6 digits each.
Simultaneous display of Energy for EB & DG in
single page.
Displays Basic : VLL, VLn, A (Avg. & PW), F.
Power : W, PF (Avg. & PW).
Energy : Wh, LH, ON hrs OLD Wh, OLD
LH(both for EB & DG)
Optional - Programmable relay output upto 2
relays.
Options : Under Voltage, Over Voltage, Under
Amps, Over Amps, Under Frequency, Over
Frequency, Under PF, Over Watts, Over Wh, and
Phase missing (both for EB & DG).
Programmable tripping time upto 180 sec with
hysteresis of 1%.
Additional Features: LG 3220
2 Row display with 6 digits each.
Simultaneous display of Energy for EB & DG in
single page.
Displays W, PF (Average & Phasewise).
Wh, OLD Wh, (both for EB & DG)
Optional - Programmable relay output upto 2
relays.
Options : Under PF, Over Watts, Over Wh, and
Phase missing (both for EB & DG).
Programmable tripping time upto 180 sec with
hysteresis of 1%.
Additional Features: LG 5120L
Energy is programmable to Wh or VAh with 7
digit resolution and 4 digit resolution for
instantaneous parameters.
Displays Basic : VLL, VLn, A (Avg. & PW), F.
Power : W, PF (Avg. & PW).
Energy : Wh, LH, ON hrs., OLD Wh, OLD
LH (both for EB & DG)
Optional - Programmable relay output upto 2
relays.
Options : Under & Over (Voltage, Amps,
Frequency), Under PF, Over Watts, Over Wh, and
Phase missing (both for EB & DG).
Programmable tripping time upto 180 sec with
hysteresis of 1%.
Common Features
Additional Features: LG 5220
LG+ 3220 ( Two Row / 3121 (Single Row)
LG+ 5120L
Typical Connection Scheme for Dual Energy Measurements
Note: Additional error of 0.1% of full scale, for meter input current below 500mA
R Y B N
AMF PANEL
Potential free
contact
R
Y
B
N
R
Y
B
N
Require only 240V AC as AMF input
Source 2
PowerGrid Power
METER NMETER 1
Technical Specification :
Specification Description
Accuracy:
Sensing/Measurement:
Input voltage:
Input Frequency:
Input current:
Aux-Supply:
Display Type:
Display Resolution:
CT PT Ratio Max:
Communication:
Weight:
Class 1 Default as per IEC 62053-21, Class 0.5 as per IEC 62053-22.
True RMS, 1 Sec update time. 4 Quadrant Power & Energy.
4 Voltage inputs (VR, VY, VB, VN).
Programmable 110 or 415V LL Nominal (Range 50 to 550V LL).
Primary Programmable up to 999 kV. Burden: 0.2VA Max. per phase.
45 - 65Hz
Current inputs (AR, AY, AB) 500mA - 6A (Field configurable 1A or 5A).
Primary programmable up to 99 kA.
Overload: 10A max continuous, 50A max for 3 Sec.
Burden: 0.2VA Max. per phase.
(Control Power)- 80 - 300V AC/DC, 40-70Hz. Burden: 5VA Max
LG+/µG+: 10mm height bright red LED display. LCD: 10mm height bright LCD.
4 digits for instantaneous, Integrated: 6digits for LED, 7digits for LCD
2000 MVA programmable.
Rs485 serial channel connection, Industry standard Modbus RTU protocol
(RS232 optional).
Baud rate: 4800 bps to 19200 bps. (Preferred 9600bps).
Isolation: 2000 volts AC isolation for 1 minute between communication and
other circuits.
Unpacked: 300 gms, Packed: 400 gms.
OPTION 2
Non-Dual Source Meter
RS 485
Gateway
Wireless Non-Dual Source Meter (Zigbee or WiFi)
METER 1METER 64
METER 1 METER 64
Serv
er
METER 2
DG
Ethernet to PLC
PLC to
Ethernet
Gateway
PLC
METER 2
Wh
LG 1 1 1 9+
LITTLE GENIUS+
PRG
OLDREV
W
VA
PF
OPTION 1
ECO friendly lead free 18 months warranty
Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters
| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input
Output | Transducers | Converters
HO & Unit-I:
Plot No.: 47-P, Hardware Park, KIADB,
Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,
Bengaluru - 562149 Karnataka INDIA.
Unit-II:
Goutham Garden, No. 4, Veerapandi,
Coimbatore - 641019 Tamilnadu INDIA
T: 0422 2697200 TF: 0244 2695200
Unit-III:
#764, 4th Phase, 707, Yelahanka New Town,
Bengaluru - 560 064 Karnataka INDIA
T: +91 80 28461744
ELMEASURE INDIA PRIVATE LIMITED
Product Selection Guide :
Mechanical Specification:
Safety: Designed to meet protection class III, pollution degree 2.
Protection against shock by double insulation.
Clearance and Creepage meets as per UL 61010 safety standard.
Finger touch proof terminals to voltage and current connections.
Environment:
Operating temperature -10°C to +55°C (14°F to 131°F)
Storage temperature -25°C to +70°C (-13°F to 158°F)
Humidity 5% to 95% non condensing.
Protection index IP 51 (IP 54 front option)
Recommended wire gauge 12 to 14 SWG
Safety and Environmental SpecificationApplicable Standards :
Test of insulation properties
Test of Accuracy requirements
Test of electrical requirements
Radio interference suppression
Fast transient burst test
Damped oscillatory waves immunity test
Test o f immunity to electromagnetic RF fields
Test of immunity to conducted disturbances,
Induced by radio-frequenc y fields
Test of immunity to electrostatic discharges
Surge immunity test
Test of the effect o f the climatic environments
Mechanical tests
Test of protection against penetration of dust
and water
Test of resistance to heat and fire
IEC 60060-1
IEC 62052-11
IEC 62052-11
CISPR 22
IEC 61000-4.4
IEC 61000-4.12
IEC 61000-4.3
IEC 61000-4.6
IEC 61000-4.2
IEC 61000-4.5
IEC 60068-2
IEC 60068-2
IEC 60529
IEC 60695-2
Safety standard IEC 61010 – 1
MODEL NO.
BASIC POWER ENERGY OPTIONAL FEATURE
LG 5110+
LG 5310+
LG 3399+
LG 5220 (DS)+
LG 3220 (DS)+
LG 1119+
µG 5110+
LG 1129+
LG 1100+
µG 1119+
µG 1129+
µG 1100+
LG 5110L+
LG 5120L+
LG 1119L/D+
LG 1129L/D+
LG 5110D+
ACC
CLASS
1.0/0.5VLL
RYB
VLL
VLL
VLL
VLL
VLL
VLL
VLL
VLL
VLL
Load Hrs/
ON Hrs
PULSE
O/P
DIGITAL
O/PRS485
LH
LH & OH
LH
LH
LH
LH
LH & OH
1
2
2
2
1
2
2
1
LCD / DinRail Version
+LG 3399: Wh and PF any two parameters [Basic (VLL,VLN,AMP,Hz) or W or VA] programmable+LG /µG+ 1119/L/D: Any one parameter [W or PF or VA or Wh] programmable+LG /µG+ 1129/L/D: Any two parameters [Basic (VLL,VLN,AMP,Hz) or W or PF or VA or Wh] programmable
# kWh / kVAh Programmable at site.Zigbee Communication Option Analog Output For DinRail Version only RS485 Communication Option
AMP
RYB
AMP
AMP
AMP
AMP
AMP
AMP
AMP
AMP
AMP
W
RYB
W
W
W
W
W
W
W
W
W
PF
RYB
PF
PF
PF
PF
PF
PF
PF
PF
PF
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
VA
RYB
VA
VA
VA
VA
VA
VA
#kWh/
kVAh
Wh
Wh
Wh
Wh
Wh
Wh
Wh
Wh
Wh
Wh
OLD
ENERGY
OLD
OLD
OLD
OLD
OLD
OLD
OLD
OLD
OLD
OLD
OLD
OLD
OLD
OLD
OLD
OLD
RS232VLN
RYB
VLN
VLN
VLN
VLN
VLN
VLN
VLN
VLN
VLN
Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel)
96 × 48 mm (Depth 45mm behind Bezel)
Panel Cutout:+2 +290 x 90 mm-0 -0 +2 +290 x 42 mm-0 -0
92mm
44
mm
90 mm
90 m
m
Panel
Clamp
Panel Cutout
LG 3100+
PC
/LG
P/V
7/1
01
7
Restricted Option
Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE
Contact for certification details
www.elmeasure.com
Intertek4007051
CM
DEMAND CONTROLLER
EN & PN
Multifunction Meter | Load Manager | Import Export | Harmonics |
Digital/Analog Input or Output | K-factor
HIGH-END
MULTIFUNCTION METER
FOR COMPREHENSIVE
ENERGY MANAGEMENT!
www.powercorporation.in
Features:
True RMS measurement.
Simultaneous sampling of Volts & Amps.
High / low recording VLL, VLN, A, Hz, W, VA, PF,
VAr value storage with time stamp.
Byte order option - Field Programmable Float /
Little Endian / Big Endian data format.
Accuracy class 1.0 as per IEC 62053-21, 0.5s
option).
User programmable Password Protection.
Auto-Scaling of Kilo, Mega and Giga decimal
point.
Neutral Current (calculated) , RPM display.
Clearance and Creepage distance meets
UL- 61010.
Programmable starting current in % of 5A
secondary. Default 0.4%.
Selectable VA measurement - Vector/Arithmetic/
Vector harmonics.
K-Factor V & A (all three phase).
Programmable parameter update rate - 1sec. to
5sec. (Default 1sec.).
Programmable Auto scrolling time - 1 sec. to 10
sec. (Default 5 sec.).
Dynamic communication - user selectable
register map.
Programmable Energy display - Counter based or
Resolution based.
Energy resetting @ 999999 kVAh × Transformer ratio.
Reverse lock, user programmable for positive energy
accumulation. (Default: No lock)
Front LED pulse 10000 imp/kWh.
OLD register to store previously cleared energy & LH
values.
% of unbalance V & A for all the phases.
THD for Voltage and Current.
Ampere hour (Ah) and PF average parameters.
Phase Angle measurement.
Optional Features EN, PN :
Digital outputs - 4 potential free contacts with
programmable time delay. Hysteresis 1%.
Trip time 1 to 180 sec. Programmable.
TOD option ( Energy & Demand upto 6 slots ).
User programmable - Pulse output (POP) on time -
50 to 500 msec.
Analog / Digital I/p upto 2. Accuracy class 1% FS
Analog Output - Two independently programmable
to 0-20 mA (or) 4-20 mA output, configurable to any
VLL, A, F, W, PF, VA parameters.
Individual Harmonics upto 31st order.
Datalogger - 1MB / 8MB optional.
Additional Features for PN2 programmable parameters.
Phase wise Voltage & Current Wave Forms.
LCD 7 parameter display at a time, 7 digit
energy.
Wave form communication through ELNET
Software.
Power save mode with Enable/Disable
option.
Demand Controller with 1 Relay, 2 Relay & 4
Relay outputs.
RTC can be adjusted using external
communication.
Upto 60A or 100A direct measurements using
Hanging CT.
Dual port communication.
Demand updation @ 1 sec.
Ethernet / Zigbee communication.
Features ParametersPN7700LMEN8400LM
PN7710EN8410
PN7710DMCEN8410DMC
Default Optional feature - no restriction on combination of options
Restricted optional feature - Combination of all restricted options may not be possible in a single product
LM : Load Manager
DMC : Demand Controller
*Indicates Non UL/ETL products
}
Basic
Line to Neutral Voltage VLN Avg, VR-N, VY-N, VB-N
Line to Line Voltage VLL Avg, VR-Y, VY-B, VB-R
Line Current A Avg, AR, AY, AB,
Neutral Current Computed AN
Frequency, RPM (Generator application) Hz, RPM
V & A Phase Angle VR, VY, VB, AR, AY, AB
Unbalance V & A % V, % A, VR, VY, VB, AR, AY, AB
Power
Active Power W Total, WR, WY, WB
Apparent Power VA Total, VAR, VAY, VAB
Reactive Power VAR Total, VAR R, VAR Y, VAR B
Power Factor PF Avg, PFR, PFY, PFB
Energy / Integrated
Active Energy Wh
Apparent Energy VAh
Reactive Energy VARh-Ind, VARh-Cap
Load Hrs, No. of Interruption, Life Timer LH, Intr, On.Hr Ah, PF Avg
Old (Energy, Load Hrs) Old (Wh, VAh, VARh Ind/Cap, LH, ) PF, AVG, Ah
Harmonics
Voltage THD THD% VR, VY, VB
Current THD THD% AR, AY, AB
K Factor K Factor: VR, VY, VB, AR, AY, AB
Events (High/Low)/ With time stamp
Voltage VLL, VLN VLL, VLN
Current A
Frequency Hz
VA VA
Watts W
VAR VAR
Power Factor PF
Demand (Optional)* Programmable to any one of the below
Active Power (W) Watt
Apparent Power (VA) VA
Reactive Power (VAR) VAR
Current Average (A.Avg) A Avg
Control Features (Optional)*
Digital Output (Up to 4 relay)
Tripping time (1-180 sec)
Analog Output / Analog Input Up to 2
Special Features (Optional)
Data Logging with Time stamp 1MB/8MB. Refer Table 1
Received/Delivered (Import/Export)/Net Wh, VAh, VArh Ind/Cap,{ PF.Avg, Ah } only Rec & Del , Lh
60A, 100A Direct measurement* 3 Phase (Hanging CT)
Individual Harmonics V & A ( All Three Phases )
Communication (Optional)*
RS-485 or RS-232 (MODBUS) or Ethernet or Zigbee* RS 232 / RS 485 / Ethernet / Zigbee
Programmable sliding/block,
demand period, forcast/
step demand control
31st 31st 31st
RTC
Based
RTC
Based
4 relay
Sliding
window
2 relay
EN 8499 Note: This model can be customized for any parameters available in EN 8400LM
Displays all Energy parameters (Wh, VAh, VARh ( Inductive & Capacitive) parameters.
Received /Delivered (Import/Export) Energy option.
Separate Load hours for Received, Delivered and Net.
OLD register to store previously cleared energy values and load hours.
Pulse output - Programmable pulse width of 50 mS to 500 mS (Optional).
RS 485/232 Optional.
Key Unique Features
Demand Management :
Monitoring - Helps to visualise the demand profile during a billing cycle.
Demand peaks with date & time can be identified in the meter as well as
ElMeasure's ElNet software. The events can be studied and related with the
production events such as starting of furnace or a large motor etc., and helps to
decide on switching/staggering of loads etc.
Control - Enables user to program the threshold values of max demand and
initiate ALARM/ CUT-OFF when the Forecast Demand/ Present Demand/ Max
Demand surpasses the threshold values. This will help the user from exceeding
the sanctioned demand and avoid causing a trip or paying huge penalty.
Additional Load - By this feature the user shall be able to decide to transfer the
exact quantum of load from EB to DG or vice versa for economic power.
High Low Event Recording for V, A, Hz, VA, W, VAr, PF
Protection of 3 phase system against single phasing, low & high voltage, over
load, highly lagging and leading PF, Hz etc. Navigator can trap such events for
future reference.
Identify, record unbalance voltage,
currents and helps the user to identify the
root cause. Unbalance over-burdens the
electrical system and affects in the form of
over loading of cables, motors and
switchgear.
PF Management :
Lower the Avg PF higher the system
inefficiency. So this enables the user to
maintain a healthy PF level. The Digital
output features can be used to initiate
alarm when the Avg PF crosses the user
programmed threshold values (Lead/ Lag).
Data Logging with Time Stamp:
The information is needed in all types of businesses to determine performance,
quality, efficiency, cost reduction, fuel consumption monitoring and many other
critical factors. This feature provides important and accurate data for analysis.
WVA
VLL
Harmonics up to 31st level
Presence of THD will urge the user to identify
the polluting loads and take necessary action
to mit igate harmonics through an
appropriate harmonic filter, save energy to
improve plant & equipments efficiency.
Monitors Basic , Power & Energy
Parameters
Provides the complete spectrum of Electrical
system and helps in study of load pattern.
Process Integration:
Integration of process parameters such as temperature, Oil level, RPM, Pressure
etc. giving greater flexibility to monitor them along with electrical parameters.
Control Features:
4 user defined potential free Digital Output based on threshold setting for
protection relay for any parameter with programmable trip time to protect the
equipments from electrical abnormalities.
Power Quality Check/Management:
Monitoring phase angle will help the user to identify the causes such as
deterioration in the distribution transformers, cables & cable termination,
presence of harmonics etc.
Cross Verification of Electricity Billing:
Helps the user to cross verify with the tariff meter and initiate suitable action if the
values have a wide disparity.
Automatic connection or disconnection of Gensets connected to common
bus .
Keep equipment in safe region.
Protection of equipment from Under/ Over Voltage or Current or
Frequency.
Process control.
Protection of 3 phase equipment from Single phase prevention, Over load
etc.
Typical ApplicationsDigital Outputs : (Up to 4 relay Outputs)
4 User defined potential free relay outputs based on threshold setting.
Protection relay for any of Under/Over VLL, A, Hz Over (W, VA, Wh) Under
(PF), Phase reversal, Single Phase, Analog inputs.
Digital O/P parameters- A.Thd, V.Thd, rev.A, S1 phase, wh .revd, VA, W, under
PF, under ( Analog I/P 1 , Analog I/P 2, F, A, VLL), over ( Analog Input 1, 2 , F,
A, VLL)(A.thd, V thd), An In 1 & 2 ( Under & Over), rev A, S1 .ph, wh.recd, PF,
VA,W, (under & over ) [F,A,VLL] also for RD models, wh.devd.
Programmable trip time 1 to 180 sec to suit different load conditions.
Rating of control relays: NO contact SPST 2A, 250 VAC / 30 VDC .
PC
/NA
V/V
7/1
017
Multiplication factor for counter based energy mode
Applicable Standards:
Safety: Designed to meet protection class III, pollution degree
2.
Protection against shock by double insulation.
Clearance and creepage meets UL 61010 safety standard.
Finger touch proof terminals to voltage and current
connections.
Environment:
Safety and Environmental Specifications:
Energy Reset : 999999 kVAh × Transformer ratio
1 Minute to 12 hours
interval programmable.
Data interval and
parameter can be
selected through
communication.
No of RecordsNo of
Parameters 1MB 8MB
Table 1
1
2
4
9
14
29
121920
81280
48768
24384
16256
8128
982080
654720
392839
196416
130944
65472
Optional
Programmable
Data Logging
Multiplication
Factor:
Full Scale kW
3 V Pri LL x A
Pri / 1000
0.4kto4.0k
0.01
4.01kto40k
0.1
40.1kto400k
1.0
400.1kto4,000k
10
4Mto40 M
100
40 Mto400 M
1000 10000
400 Mto4000 M
Unit of display KWH MWH GWH
Test of insulation properties
Test of Accuracy requirements
Test of electrical requirements
Radio interference suppression
Fast transient burst test
Damped oscillatory waves immunity test
Test o f immunity to electromagnetic RF fields
Test of immunity to conducted disturbances,
Induced by radio-frequenc y fields
Test of immunity to electrostatic discharges
Surge immunity test
Test of the effect o f the climatic environments
Mechanical tests
Test of protection against penetration of dust
Test of resistance to heat and fire
IEC 60060-1
IEC 62052-11
IEC 62052-11
CISPR 22
IEC 61000-4.4
IEC 61000-4.12
IEC 61000-4.3
IEC 61000-4.6
IEC 61000-4.2
IEC 61000-4.5
IEC 60068-2
IEC 60068-2
IEC 60529
IEC 60695-2
Safety standard IEC 61010 – 1
and water
-10°C to +55°C (14°F to 131°F)
-25°C to +70°C (-13°F to 158°F)
5% to 95% non condensing.
IP 51 (IP 54 front option)
12 to 14 SWG with U type
lug of 6.75 mm width max.
Operating temperature
Storage temperature
Humidity
Protection index
Recommended connecting
wire
Specification Description
Technical Specification:
Mechanical Specification:
90 mm
90
mm
Panel
Clamp
Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel)
Panel Cutout:+2 +290 x 90 mm-0 -0
90
mm
96
mm
50 mm Panel Cutout
Class 1 Default , as per IEC 62053-21
Class 0.5, 0.5S as per IEC 62053-22
True RMS, 1 Sec update time.4 Quadrant Power & Energy
(RD Option).
4 Voltage inputs (VR, VY, VB, VN)
Programmable 110 or 415V LL Nominal (Range 80 to 520 VLL)
Primary Programmable up to 999 kV. Burden: 0.2VA Max. per phase.
45 - 65 Hz
Current inputs (AR, AY, AB) 50mA - 6A (Field configurable 1A or 5A).
Primary Programmable up to 99 kA.
Overload: 10A max continuous, 50A max for 3 Sec
Burden: 0.2VA Max. per phase.
Control Power 80 - 300V AC/DC, 40-70Hz, 48V DC (optional)
Burden: 5VA Max.
eNavigator: 10mm height bright red LED display
Power Navigator: 6mm height bright LCD graphical display.
4 digits for instantaneous,Integrated: EN - 6 digits, PN - 7 digits.
2000 MVA Programmable. Note : Additional error of 0.1%.
Rs485 serial channel connection, Industry standard Modbus RTU
protocol (Optional: RS232 / Ethernet / Zigbee).
Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps)
Isolation: 2000 volts AC isolation for 1 minute between
communication and other circuits.
Zigbee communication (Range: 50 meter length)
Unpacked: 300 gms, Packed: 400 gms
Accuracy:
Sensing/
Measurement:
Input voltage:
Input Frequency:
Input current:
Aux-Supply:
Display Type:
Display Resolution:
CT PT Ratio Max:
Communication:
Weight:
Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters
| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input
Output | Transducers | Converters
Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE
HO & Unit-I:
Plot No.: 47-P, Hardware Park, KIADB,
Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,
Bengaluru - 562149 Karnataka INDIA.
Unit-II:
Goutham Garden, No. 4, Veerapandi,
Coimbatore - 641019 Tamilnadu INDIA
T: 0422 2697200 TF: 0244 2695200
Unit-III:
#764, 4th Phase, 707, Yelahanka New Town,
Bengaluru - 560 064 Karnataka INDIA
T: +91 80 28461744
ELMEASURE INDIA PRIVATE LIMITED
ECO friendly lead free 18 months warranty
BM
SIMULTANEOUS MEASUREMENT
OF VARIOUS ELECTRICAL
PARAMETERS!
www.elmeasure.com
BRANCH CIRCUIT MONITORMulti Channel Load Manager | Cost Saving | Compact Design
BM 5120
1
2
3
4
www.powercorporation.in
A/C Load
Data
Center
Motor/PumpsLoadLMS
Multi-channel data collection.
3 Phase, 4 channels or Single phase 12 channels
Displays Basic, Power and Energy parameters.
Optional Pluggable Zigbee communication or Ethernet
( Default RS 485).
Space saving compact design for easy installation into
existing panel boards.
True RMS measurements.
Simultaneous sampling of Volts & Amps.
Accuracy class 1.0 as per IEC 62053-21, Class 0.5 as per IEC
62053-22.
User programmable password protection.
Energy resetting @ 999999 KVAh × Transformer ratio.
Features:
Displays more than 25 parameters Basic, Power and Energy.
Displays Basic : VLL, VLn, A (Average & Phasewise), F.
Power: W, PF,VA (Total & Phasewise).
Energy : Wh, LH, VAh, VARh ( PhaseWise for every Channel & Total Channel
wise).
OLD register to store the previously cleared Energy value & LH.
Measures:
Specification of Zigbee (coordinator and Router) :
Network Support IEEE 802.15.4 and Zigbee
Data Rates 256 kbps
Frequency Band 864 MHz – 865 MHz (16 channels) with auto
scanning
Modulation techniques DSSS
Wireless Security AES 128-bit encryption
Tx Output Power 4.5 dBm Rx
Sensitivity -97 dBm
Distance covered 20 meters
Note: Customization can be done for other parameters
provided volume justify
Connection Details:
The Branch Circuit Monitor (Power Distribution Unit) is ideal in Data center
where it can connect and control up to 12 channels of Branch monitoring.
Controlling can be done using add on Relay unit with Rs485. BM is a meter for
measuring Voltage, Current, Power and Energy for every circuit in a power
distribution unit or Rack. One can use Split core CTs or Regular CTs to monitor
the current in every branch
BRANCH CIRCUIT MONITOR (BM)
MODBUS
ENERGY MANAGEMENT SOFTWARE
Solution Architecture :
Connection Details:
Optional
Zigbee | Ethernet |
GPRS Module with memory
up to 14 GB
GW 2000D
BM 5120
1
2
3
4
BM 5120
1
2
3
4
Address
Communication Register Map:
Sl No. Parameter Data TypeChannel 1 Channel 2 Channel 3 Channel 4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
Watts Total
Watts R phase
Watts Y phase
Watts B phase
PF Ave. (Inst.)
PF R phase
PF Y phase
PF B phase
VLL average
Vry phase
Vyb phase
Vbr phase
VLN average
V R phase
V Y phase
V B phase
Current Total
Current R phase
Current Y phase
Current B phase
Frequency
Wh Received
R-Phase Wh
Y-Phase Wh
B-Phase Wh
Load hour Recd
R-Phase load hour
Y-Phase load hour
B-Phase load hour
VAR total
VAR R phase
VAR Y phase
VAR B phase
VA total
VA R phase
VA Y phase
VA B phase
VAh total
VARh IND total
VARh CAP total
VAh R phase
VAh Y phase
VAh B phase
VARh IND R phase
VARh IND Y phase
VARh IND B phase
VARh CAP R phase
VARh CAP Y phase
VARh CAP B phase
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
Unsigned Long
Unsigned Long
Unsigned Long
Unsigned Long
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
4101
4103
4105
4107
4109
4111
4113
4115
4117
4119
4121
4123
4125
4127
4129
4131
4133
4135
4137
4139
4141
4143
4145
4147
4149
4151
4153
4155
4157
4159
4161
4163
4165
4167
4169
4171
4173
4175
4177
4179
4181
4183
4185
4187
4189
4191
4193
4195
4197
4201
4203
4205
4207
4209
4211
4213
4215
4217
4219
4221
4223
4225
4227
4229
4231
4233
4235
4237
4239
4241
4243
4245
4247
4249
4251
4253
4255
4257
4259
4261
4263
4265
4267
4269
4271
4273
4275
4277
4279
4281
4283
4285
4287
4289
4291
4293
4295
4297
4301
4303
4305
4307
4309
4311
4313
4315
4317
4319
4321
4323
4325
4327
4329
4331
4333
4335
4337
4339
4341
4343
4345
4347
4349
4351
4353
4355
4357
4359
4361
4363
4365
4367
4369
4371
4373
4375
4377
4379
4381
4383
4385
4387
4389
4391
4393
4395
4397
4401
4403
4405
4407
4409
4411
4413
4415
4417
4419
4421
4423
4425
4427
4429
4431
4433
4435
4437
4439
4441
4443
4445
4447
4449
4451
4453
4455
4457
4459
4461
4463
4465
4467
4469
4471
4473
4475
4477
4479
4481
4483
4485
4487
4489
4491
4493
4495
4497
*Optional (26-49)
Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters
| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input
Output | Transducers | Converters
Sales Offices: BANGALORE | CHENNAI | MUMBAI | DELHI | HYDERABAD | USA | UAE
HO & Unit-I:
Plot No.: 47-P, Hardware Park, KIADB,
Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,
Bengaluru - 562149 Karnataka INDIA.
Unit-II:
Goutham Garden, No. 4, Veerapandi,
Coimbatore - 641019 Tamilnadu INDIA
T: 0422 2697200 TF: 0244 2695200
Unit-III:
#764, 4th Phase, 707, Yelahanka New Town,
Bengaluru - 560 064 Karnataka INDIA
T: +91 80 28461744
ELMEASURE INDIA PRIVATE LIMITED
PC
/BM
/V0
/11
17
Safety and Environmental Specification:
Dimension Bezel : 90 x 90 mm (Depth 67mm)
Mechanical Specification:
Specification Description
Technical Specification:Applications :
Benefits :
For remote reading and control, the BM is
supported by ElNet Software, designed for
remote setup and data viewing and analysis.
Building Management System: With the open
modbus protocol, the BM can interface any
system, such as building management, HMI etc.
Compact : Ideal for Data Center.
Ideal for apartments / commercial complexes
billing and load pattern study on individual
phase.
Individual phase kWh measurement provides
user flexibility of measuring 3 phase 4 channels
or single phase 12 channels.
Primary current can be independently
configured making it ideal for any kind of
industry or up-gradation.
Safety: Designed to meet protection class III, pollution degree 2.Protection against shock by
double insulation. Clearance and Creepage meets as per UL 61010 safety standard.
Environment:
Operating temperature -10°C to +55°C (14°F to 131°F)
Storage temperature -25°C to +70°C (-13°F to 158°F)
Humidity 5% to 95% non condensing.
Recommended wire gauge 12 to 14 SWG
Note: Additional error of 0.1% of full scale, for meter input current
below 500mA for 5A setting
Accuracy: Class 1.0 (default) as per IEC 62053-21, Class 0.5 as per IEC 62053-22
(Optional).
Measurement Range: 1:500 for channel 1 & 2, 1:120 for channel 3 & 4
Sensing/
Measurement: True RMS, 1 Sec update time; 4 Quadrant Power & Energy
Input voltage: 4 Voltage inputs (VR, VY, VB, VN) Programmable 110 or 415V LL
Nominal (Range 80 to 550V LL) Primary Programmable up to 999 kV.
Burden: 0.2VA Max. per phase.
Input Frequency : 45 - 65 Hz
Input current: Current inputs [AR, AY, AB], 4 Channels - Each channel is
independently configurable. Primary Programmable up to 99 kA.
CT output : Can be upto 1000 mV or 100 mA from Split core CT or Hanging
CTs - Manufacturing option.
Aux-Supply (Control Power): 80 - 300V AC / DC, 40-70Hz. Burden: 5VA Max.
Display Resolution: 6 digit LED for Energy, 4 digit for Instantaneous
CT PT Ratio Max: 2000 MVA Programmable.
Communication: RS485 interface. Industry standard Modbus RTU protocol.
Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps)
Isolation : 2000 volts AC isolation for 1 minute between communication and
other circuits.
Weight:Unpacked: 300 gms Packed: 400 gms
Mechanical Specification: Dimension : 90mm * 72mm * 65mm
Current Transformers
Hang on CT- 5A or 50A or 100A
Split Core CT-100A | 400A | 1000A
Clip on CT-5A | 50A | 100A | 250A
ECO friendly lead free 18 months warranty
ENERGY & PROCESS
MONITOR
EPM
Contact for certification details
www.elmeasure.com
User Friendly | Cost Effective | Field Programmable
DEVICE TO MONITOR
PROCESS AND ENERGY
TOGETHER!
www.powercorporation.in
Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters
| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input
Output | Transducers | Converters
Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE
HO & Unit-I:
Plot No.: 47-P, Hardware Park, KIADB,
Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,
Bengaluru - 562149 Karnataka INDIA.
Unit-II:
Goutham Garden, No. 4, Veerapandi,
Coimbatore - 641019 Tamilnadu INDIA
T: 0422 2697200 TF: 0244 2695200
Unit-III:
#764, 4th Phase, 707, Yelahanka New Town,
Bengaluru - 560 064 Karnataka INDIA
T: +91 80 28461744
ELMEASURE INDIA PRIVATE LIMITED
Specification Description
Accuracy:
Sensing/
Measurement:
True RMS, 1 Sec. update time. 4 Quadrant Power & Energy.
Input Voltage: 4 Voltage inputs (VR, VY, VB, VN).
Programmable 110 or 415V LL Nominal (Range 50 to 550V LL)
Primary programmable upto 999 kV. Burden: 0.2VA Max. per phase.
Input Current: Current inputs (AR, AY, AB), 500 mA – 6A (Field configurable 1A or 5A).
Primary programmable upto 99 kA.
Overload: 10A max. continuous, 50A max. for 3 sec.
Burden: 0.2VA Max. per phase.
Aux-Supply
(control power):
80 – 300V AC/DC, 40-70Hz.
Burden: 5VA Max.
4 digits for Instantaneous, Integrated: 6 digits.
CT Ratio: 2000 MVA programmable.
Display resolution:
Weight: Unpacked: 300 gms, Packed: 400 gms
Features :
Technical Specification:
Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel)
90 mm
90 m
m
Panel
Clamp
Panel Cutout:+2 +290 x 90 mm-0 -0
Mechanical Specification:
90 m
m
96 m
m
50 mm Panel Cutout
Input Frequency: 45 - 65 Hz
True RMS measurement.
Simultaneous sampling of Volts & Amps.
Energy display programmable-counter based or
resolution based.
Energy resetting at 999999 kVAh × Transformer ratio.
Positive energy accumulation even with CT polarity
reversal, reverse lock programmable.
User programmable password protection.
Auto scrolling.
Auto scaling of Kilo, Mega, Giga and Decimal point.
Low PT, CT burden.
Displays - Basic: VLL, VLN, A (Avg. & Phase wise), F;
Power: W, PF, VA (Avg. & Phase wise); Energy: Wh or
VAh programmable (any one), Load hrs, Max & Min (
VLL and Amps), OLD Wh, OLD LH.
Front LED pulse 10000 imp/kWh of secondary input.
Programmable PT, CT ratio upto 2000 MVA.
Programmable kVAh (default kWh) for meters.
Energy is programmable to Wh or VAh with 6 digit
resolution LED and 4 digit resolution for
instantaneous parameters.
80 to 300 V AC/DC Auxiliary supply.
Additional Features:
EPM 5110
High & Low measurements for Voltage and Current
(Last one minute of data).Mm 2100
One Digital input (RPM). Measurement capability up
to 72000 RPM
Displays last one minute RPM. Cumulative RPM
through RS 485.
Optional: 2 Analog input for 4 – 20 mA or 0 – 20 mA
(Flow, Pressure, Temperature, etc.).
3 Digital Input optional.
Process Integration:
Integration of process
parameters such as
temperature, flow, pressure,
RPM, etc. giving greater
flexibility to monitor them
along with electrical
parameters.
DI
AI
PC
/EP
M/V
0/1
117
Clearance and creepage distance meets safety
standard.
Finger touch proof terminals to voltage and current
connections.
Parameter name and value displaying using 7
segment LED's.
Field programmable Star (Wye) or Delta or Single
phase configuration.
Class 1.0 (default) as per IEC 62053-21, Class 0.5 as per
IEC 62053-22 (Optional).
Communication: Rs485 serial channel connection, industry standard Modbus RTU
protocol (RS232 optional). Baud rate: 4800 bps to 19200 bps.
(Preferred 9600 bps.) Isolation: 2000 volts AC isolation for 1 minute
between communication and other circuits.
Intelligent:
ECO friendly lead free 18 months warranty
INTELLIGENT
AUTOMATIC CHANGEOVER
WITH CURRENT LIMITER
iACCL
FOR A SEAMLESS,
UNINTERRUPTED CHANGEOVER
BETWEEN POWER SOURCES!
www.elmeasure.com
Current | Voltage | Frequency | Energy
www.powercorporation.in
PC/IACCL/V3/1017
180 - 300V AC LN
the system will be
ON for DG delay time and OFF for cycle1 time and switches ON
once again. If the over current still present, it goes on with cycle
2,3,4,4,4 as per the no. of trip cycles programmed. If the ON / OFF
cycle is completed the device trips and permanently disables the
output. The reset can be done by pressing the reset key manually
40A).
Intelligent Overload tripping with AC1 to AC3 behavior
Energy (4 digit for single phase),
Or through the mobile app when network
Optional EB Energy and Voltage
Alpha
R NY B R NY B
is available
measurement for 3 phase
Upto 40A 100/125A
VAC
5 - 30 sec programmable 5 - 30 sec programmable
(Tripping based on
(Din rail option up to 40A)
AC3 behavior)
4 digitEnergy
ECO friendly lead free 18 months warranty
ACCL
32A
500 gms
90 x 76 x 6
iACCl 100 iACCl
INTELLIGENT
EARTH FAULT RELAY
iEFR
FOR A SEAMLESS,
PROTECTION AGAINST EARTH
FAULT AND OVER LOAD/EARTH
TO NEUTRAL VOLTAGE
PRG
EFR 400Earth Fault Relay
COM
30sA
sA
SET A
MPS
SET TIMEsTsT
TESTRESET
www.elmeasure.com
Contact for certification details
www.powercorporation.in
True RMS measurement.
Common protection for earth fault and over load
Clearance and creepage distance meets UL 61010 safety
standard.
Inverse curve - trip time is inversely proportional to fault
current. This EFR is Intelligent, when the fault current is 10
times higher than the set current, it trips 10 times faster.
Field programmable trip current and trip time through front
panel keys with password protection.
Continuous fault current display (Programmable) - fault
current continuously displayed to enhance the user to
understand the quality of electrical network / machine
online.
Continuous display of trip fault current (Programmable) - In
case of tripping, iEFR captures and displays the tripped
current with 4 digit resolution, which helps the user to
analyze and correct the problem.
Continuous scrolling display for set current and set time.
Wide input range 30mA to 5A and the trip time
programmable from 50ms to 30 seconds.
Manual test and reset keys.
RS485 communication option.
Features:
Microcontroller based design.
Password protection.
Current sensitivity wider range 30mA - 5A.
Programmable trip time 50ms - 30 sec.
Selection through soft keys (No DIP switches).
Continuous earth fault value display.
Intelligent tripping based on T 1/A or definite time
Auto scrolling of trip Info. & peak fault current.
SMT reflow manufacturing process.
Benefits:
Higher technological advantage.
Helps analysis and corrective action.
Security against mishandling.
No limitations on set current.
Wider choice to suit different industry
Better IP protection and longer life.
Helps online loss analysis.
Faster and reliable protection.
Better analysis.
Higher reliability.
Unique Features:
Technical Specification:
Specification Description
Accuracy: Class 2.0FS, Time delay ±5% with minimum of 50 ms.
Auxiliary voltage: 80 - 300 V AC / DC.
Input current: Programmable 30mA - 5A, Over current 30A.
Tripping time: Programmable for fault current, 30 MA to SA
Setting ranges: Low-set (I >) : 0.05A to 5.0ALow-set time (kt >) : 0.05, 0.1, 0.2, 0.3, 0.5, 1.0, 2.0, ......, 30 sec.High-set (I >>) : 0.1A to 30A or disable.High-set delay time (t >>) : 0.05 sec. to 30 sec.
Relay contacts: Two pair of potential free NO & NC contacts. One part to EFR 200D
Contact Rating: 2 or 4 Amps @ 240V AC / 24V DC.
Mounting Type: Flush or Dinrail
Communication: Rs485 serial channel connection industry standardModbus RTU protocol.Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps).Isolation: 2000 volts AC isolation for 1 minute betweencommunication and other circuits.
Tripping
Characteristics:
10sA
Protects control panels and switch boards from earth fault.
Protects motors / transformers / feeders / generators etc.,
from earth fault.
Hazardous and sensitive industries like oil refineries / pulp
industries / electrical distribution etc., can be protected.
Applications:
PC/IEFR/V1/1017
Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters
| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input
Output | Transducers | Converters
Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE
HO & Unit-I:
Plot No.: 47-P, Hardware Park, KIADB,
Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,
Bengaluru - 562149 Karnataka INDIA.
Unit-II:
Goutham Garden, No. 4, Veerapandi,
Coimbatore - 641019 Tamilnadu INDIA
T: 0422 2697200 TF: 0244 2695200
Unit-III:
#764, 4th Phase, 707, Yelahanka New Town,
Bengaluru - 560 064 Karnataka INDIA
T: +91 80 28461744
ELMEASURE INDIA PRIVATE LIMITED
ECO friendly lead free 18 months warranty
INTELLIGENT
EARTH LEAKAGE RELAY
iELR
DETECT THE LEAKAGE
CURRENT IN AN INTELLIGENT
ELECTRICAL DEVICE!
www.elmeasure.com
Earth leakage current | Trip time
Contact for certification details
www.powercorporation.in
True RMS measurement.
Clearance and creepage distance meets UL 61010 safety
standard.
Inverse curve - trip time is inversely proportional to fault
current. This ELR is Intelligent, when the leakage current is
10 times higher than the set current, it trips 10 times faster.
Field programmable trip current and trip time through front
panel keys with password protection.
Continuous leakage current display (Programmable) -
Leakage current continuously displayed to enhance the user
to understand the quality of Electrical network / Machine
online. This can be disabled through setup if required.
Continuous display of trip leakage current (Programmable) -
In case of tripping, iELR captures and displays the tripped
current with 4 digit resolution, which helps the user to
analyze and correct the problem. This can be disabled
through setup if required.
Continuous scrolling display for set current and set time.
Wide input range 300mA to 12A and the trip time
programmable from 300 ms to 30 seconds
(Optional 30 mA - 1A).
Manual test and reset keys.
RS485 communication option.
Features:
Microcontroller based design.
Peak detection and value display.
Password protection.
Current sensitivity wider range 300mA - 12A.
Programmable trip time 300ms - 30 sec.
Selection through soft keys (No DIP switches).
Continuous Earth Leakage Value Display
Programmable ).
Intelligent tripping based on T 1/A
Auto scrolling of trip Info. & peak fault current.
SMT reflow manufacturing process.
Benefits:
Higher echnological dvantage.t a
Helps nalysis and orrective ction.a c a
Security against ishandling.m
No imitations on et urrent.l s c
Wider hoice to uit ifferent ndustryc s d i
Better IP rotection and onger ife.p l l
Helps nline oss nalysis.o l a
Faster and eliable rotection.r p
Better nalysis.a
Higher eliability.r
Unique Features:
Tripping
Characteristics:
Protects control panels and switch boards from flame
leakage.
Protects motors / transformers / feeders / generators etc.,
from earth leakage.
Hazardous and sensitive industries like oil refineries / pulp
industries / electrical distribution etc., can be protected.
Complete protection for control engineering and mining
industry.
Applications:
PC
/IE
LR
/V7/1
017
10sA
CBCT Specification
Input Range : 300mA to 12A Default, 30mA - 1.0A (Optional)
CBCT: Tape Wound
Round Diameter: Inner Diameter 40mm, 60mm, 100mm,
150mm, 200mm, 250mm, 300mm
Rectangular: 150×50mm, 250×100mm, 300×100mm,
350×100mm, 400×125mm, 400×200mm, 500×225mm,
500×200mm. (Any other sizes subject to availability)
Technical Specification:
Specification Description
Accuracy: Class 2.0FS for dimension upto 200mm, Class 5.0 FS above 200mm
Input voltage: 80 - 300 V AC / DC.
Input current: Programmable 300mA - 12A.
Tripping time: Programmable 0.3 sec to 30 sec (Optional 30 mA - 1A).
Core Balance: CT type : tape wound
CBCT:
Relay contacts:
Contact Rating:
One pair of potential free NO & NC contacts.
Mounting Type: Flush.
Communication: RS 485 serial channel connection industry standard Modbus
RTU protocol.
Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps).
Isolation: 2000 volts AC isolation for 1 minute between
communication and other circuits.
Round - tape wound (Epoxy dipped option),
Rectangular - tape wound.
2Amps @ 240V AC / 24V DC.Core Balance Current Transformer - CBCT
Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel)
90 mm
90 m
m
Panel
Clamp
Mechanical Specification:
90 m
m
96 m
m
50 mm Panel Cutout
Panel Cutout:+2 +290 x 90 mm-0 -0
Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters
| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input
Output | Transducers | Converters
Sales Offices: BANGALORE | CHENNAI | MUMBAI | DELHI | HYDERABAD | USA | UAE
HO & Unit-I:
Plot No.: 47-P, Hardware Park, KIADB,
Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,
Bengaluru - 562149 Karnataka INDIA.
Unit-II:
Goutham Garden, No. 4, Veerapandi,
Coimbatore - 641019 Tamilnadu INDIA
T: 0422 2697200 TF: 0244 2695200
Unit-III:
#764, 4th Phase, 707, Yelahanka New Town,
Bengaluru - 560 064 Karnataka INDIA
T: +91 80 28461744
ELMEASURE INDIA PRIVATE LIMITED
Input Frequency: 45 65 Hz
ECO friendly lead free 18 months warranty
MOTOR PROTECTION
SYSTEM
MPS & MPU
www.elmeasure.com
ONE STOP SOLUTION
FOR MOTOR PROTECTION!
Voltage | Overload | Frequency | PF | Single phasing | Unbalance
loading of voltage and current | Neutral current | Phase reversal.
TRIP
UNSAFESAFE ALARM TRIP
MOTOR PROTECTION SYSTEM
MPS 8000
T1CLR PRGRESET
TRIP
TRIP
TRIP
SAFE
MOTOR PROTECTION UNIT
V - A - Hz - W - VA - PF - Wh
LG 5 1 10+MPU 5 1 10
REV OLD TRIP
T 1
PRG
RESET
Contact for certification details
www.powercorporation.in
Common Features: Technical Specification:
Specification Description
Accuracy:
Sensing/
Measurement:
True RMS, 1 Sec update time.
Input Voltage: 4 Voltage inputs (VR, VY, VB, VN); Programmable 110 or 415V LL
Nominal (Range 80-550V LL)Primary Programmable up to 999 kV
Burden: 0.2VA Max. per phase.
Input Current: Current inputs (AR, AY, AB) 50mA - 6A (Field configurable 1A or 5A)
Primary Programmable up to 99 kA
Overload: 10A max continuous, 50A max for 3 sec.
Burden: 0.2VA Max. per phase.
Aux-Supply
(control power):
(Control Power): 80 - 300V AC/DC.
CT PT Ratio Max: 2000 MVA Programmable.
Operational diagram for MPS & MPU
User programmable password protection.
Auto-scaling of Kilo, Mega, Giga and decimal point.
Auto scrolling.
Finger touch proof terminals for voltage and current
connections.
Clearance & creepage distance meets UL 61010 safety
standard.
Communication with PCs, PLCs, DCS through optional RS
485/232 serial interface.
Potential free output with programmable trip time for
protection.
Displays more than 25 parameters Basic (VLL, VLN, A, Hz);
Power (W, VA, PF) and Energy (kW, Load Hours).
Displays the reasons for tripping for future correction.
Programmable start time from sensing safe condition.
Programmable locked rotor current and time.
Weight: Unpacked: 300 gms, Packed: 400 gms
Parameters can be configured and its range : Parameters Default Setup Default Setup Range
MPU 5110 MPS 8000
Connection mode(ELEMNT) STAR STAR STAR/ DELTA
PT Primary (PT.Pri) 415.0 415.0 100V - 999kV
PT Secondary (PT SEC) 415.0 415.0 50V - 550V
CT Primary (CT.Pri) 5.000 5.000 0.5A - 99kA
CT Secondary (CT SEC) 5.000 5.000 0.5A - 6A
VA selection (UA.SLEC) Arith Vec.H
(Arithmetic) (Vector)
Over Voltage Line to Line 550.0 550.0 1.000 - 999kV
Under Voltage Line to Line 10.00 0.001 0.001 - 999kV
Under Current (Dry Run) 0.200 NA 0 - 99kA
Over Current 6.0 6.0 0.500 - 99kA
Over Frequency NA 60.00 25 - 200
Under Frequency NA 40.00 25 - 200
Under PF NA 0.400 0.001 - 0.999PF
Percentage Voltage Unbalance NA 7.000% 0.5 - 60%
Percentage Current Unbalance NA 7.000% 0.5 - 60%
Neutral Current NA 2.000 0.030 - 99kA
ON Delay 5.00 10.00 1 - 600 Sec
OFF Delay 5.00 3.000 1- 60 Sec
Motor ON safe status NA RELAY ON REL ON/ OFF
Locked Rotor Current 6 time fixed 30.00 1 - 999kA
(not programmable)
Locked Rotor Time Delay NA 5.00 1 - 60 Sec
Winding Short NA 10% 5 - 90%
Over Current Digital Output Absolute INV CUrV INV CUrV/Absolute
Characteristics
Poles NA 4.000 1 - 28 Poles
Reverse Lock No No NO / YES
Communication: Rs485 serial interface Industry standard Modbus RTU protocol
(RS232 optional)
Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps)
Isolation: 2000 volts AC isolation for 1 minute between
communication and other circuits.Displays ON hours , Load hours & number of interruption.
Simultaneous display of 7 parameters.
Intelligent power save mode.
Two field configurable parameter for continuous display.
Continuous Wh display even in Auto-scrolling mode.
Graphical display.
Neutral current display and protection.
Single solutions for protection of motors/equipment against
voltage, overload, frequency, PF, single phasing, unbalance
loading of voltage and current, neutral current, & phase
reversal.
Programmable (intelligent inverse time) trip time for
Volts/Overload/Hz/PF/Neutral current.
Programmable relay status High or Low for safe; 2 relays for
alarm and trip.
Detect winding shorts.
Safe/Alarm/Trip indication for on line view.
Manual re-correction after the trip.
Measures VLL, VLN, A, Hz, W, VA, PF, Neutral current, Wh,
Load hours, ON hours, No. of interruption.
Additional Features for MPS 8000:
TRIP
Load Pattern
SAFE REGIONTRIP
Sta
rt D
ela
yPr
og
ram
ma
ble
Programmable Relay Status
UNSAFE REGION
Time
Ala
rm R
ela
yfo
r W
arn
ing
Intelligent tripping based on load
Off time
Para
me
ter
like
un
de
r/o
ver
Volts
,A
mp
s, F
req
ue
nc
y, P
F, U
nb
ala
nc
elo
ad
ing
of Vo
ltag
e/C
urr
en
t, N
eutra
l curr
en
t, S
ing
le p
ha
sin
g
OFF TIMEVariable
TRIP
Load Pattern
SAFE REGIONTRIP
Sta
rt D
ela
yPr
og
ram
ma
ble
UNSAFE REGION
Time
Off time
Para
me
ter
like
un
de
r/o
ver
Volts
,A
mp
s, D
ry r
un, Si
ng
le p
ha
sin
g
OFF TIMEVariable
MPS 8000
MPU 5110
Arith(Arithmetic)/Vector
vec.H(vector harmonics)
PC/M
PS/V5/1017
Class 1.0 (default) as per IEC 62053-21, Class 0.5 as per
IEC 62053-22 (Optional).
Input Frequency: 45 - 65 Hz
ECO friendly lead free 18 months warranty
Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters
| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input
Output | Transducers | Converters
Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE
HO & Unit-I:
Plot No.: 47-P, Hardware Park, KIADB,
Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,
Bengaluru - 562149 Karnataka INDIA.
Unit-II:
Goutham Garden, No. 4, Veerapandi,
Coimbatore - 641019 Tamilnadu INDIA
T: 0422 2697200 TF: 0244 2695200
Unit-III:
#764, 4th Phase, 707, Yelahanka New Town,
Bengaluru - 560 064 Karnataka INDIA
T: +91 80 28461744
ELMEASURE INDIA PRIVATE LIMITED
PORTABLE POWER ANALYSER
CUM DATA LOGGER
iD - LOG
www.elmeasure.com
High Profile Portable Power
Analyzer with Higher Accuracy
and Data logging
USER FRIENDLY | DYNAMIC COMMUNICATION | DEMAND MONITORING
www.powercorporation.in
A variety of reports can be availed by activity, schedule and
types by specific list:
Data Quality
Exception Reports
Alarm Handling Packages
Display Groups
Historical Data Trending
Real time Trending
Dashboard
Matrix
Reports can be viable and downloaded by any format provided
and schedules can be modified based on convenient time.
*Schedulers will automatically run according to our initial
configuration
Analyzing and Reporting
The Software collects data from the plant
consolidating it into manageable information to
constantly monitor energy usage and identify the core
areas for corrective action, ensuring optimum
performance.
ElNetEnergy Management Software
Web based technology
User friendly
Enhanced security
Vector based graphics
Remote monitor and control equipment processes and
facilities with in-expensive web browsers
Report on operational status of equipment, process and
facilities
Reduce billing cycles by obtaining accounting information
directly from automation systems
Reduce service calls and manpower by using remote
diagnostics.
Use low cost secure connections to network over a
combination if ISP, Intranet, Internet and dial-up
connections
Email/SMS
Day Log book, Hourly-day Energy, Shift Energy, TOD
energy, Min max, Flexible energy report and for
abnormal Alarm conditions
SMS to the mobile for the following: abnormal Alarm
conditions, Hourly and Daily Energy
Customization is possible for any kind of Email/SMS
options
Applications
Frontline troubleshooting
Predictive maintenance
Quality of service compliance
Long-term analysis
Load studies
Energy assessments
24/7 CLOUD SERVER
Datalog
Trends - Single and multiple days Min, Max & Avg.
Table view - Single and multiple days Data Export to Excel
Alarm, Min & Max.
iD LOGGER Portable Power Analyser with Dynamic Communication,
Higher Accuracy and Data Logging
Portability
Compact Size
Modular Construction
LCD Screen
Inbuilt GPRS Communication
DATA LOGGER
iD-LOG 7700OPTION BASIC POWER ENERGY
iD LOG - Ethernet
4GB data logger (default)
Option for current measurement using
Clip CT (default) or Rogowski
iD LOG - Ethernet & GPRS
14GB data logger (default)
Kit - 1
Kit - 2
Internet
Helps you to locate, predict, prevent and troubleshoot problems in power
distribution.
Measures voltage, current, frequency, power, energy consumption, unbalance,
harmonics and inter-harmonics.
24x7 Cloud Server Data logging with Time stamp
Monitor and Control large campuses or remote facilities with inexpensive web
technology
Perform audits and analyses remotely.
Features
Benefits
Maximum Return on Investments
Reduce Energy Costs
Improve Working Environment
Identification and elimination of energy waste
Security and System Integration
Various Protocol Supported
Economically priced
High Performance and Easy configuration
Features Parameters
Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters | Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input Output | Transducers | Converters
Sales Offices: BANGALORE | CHENNAI | MUMBAI | DELHI | HYDERABAD | USA | UAE
HO & Unit-I:
Plot No.: 47-P, Hardware Park, KIADB, Huvinayakanahalli, Jala Hobli, Yelahanka Taluk, Bengaluru - 562149 Karnataka INDIA.E: [email protected]
Unit-II:
Goutham Garden, No. 4, Veerapandi, Coimbatore - 641019 Tamilnadu INDIAT: 0422 2697200 TF: 0244 2695200E: [email protected]
Unit-III:
#764, 4th Phase, 707, Yelahanka New Town, Bengaluru - 560 064 Karnataka INDIAT: +91 80 28461744E: [email protected]
ELMEASURE INDIA PRIVATE LIMITED
Specifica�on Descrip�on
Technical Specifica�on:
Accuracy:
Sensing/
Measurement:
Input voltage:
Input frequency:
Input current:
Aux-Supply:
Display Type:
Display Resolution:
CT PT Ratio Max:
Communication:
Class 1 (Default) ,IEC 62053-21
Class 0.2 with specific CT.
True RMS, 1 Sec update time.4 Quadrant
Power & Energy
4 Voltage inputs (VR, VY, VB, VN)
Programmable 110 or 415V LL Nominal
(Range 80 to 520 VLL) Primary
Programmable up to 999 kV. Burden:
0.2VA Max. per phase.
45 Hz to 65 Hz
Current inputs (333mV)
Primary Programmable up to 99 kA.
Burden: 0.2VA Max. per phase.
Built-in
6mm height bright LCD graphical display.
7 digits.
2000 MVA Programmable.
GPRS / Ethernet
} Programmable sliding/fixed window, block demand period, forcast/step demand control
Basic
Line to Neutral Voltage VLN Avg,VR-N,VY-N,VB-N
Line to Line Voltage VLL Avg,VR-Y,VY-B,VB-R
Line Current AR, AY, AB, A-avg
Neutral Current Computed AN
Frequency, RPM (Generator application) Hz, RPM
V & A Phase Angle VR, VY, VB, AR, AY, AB
Unbalance V & A % V, % A, VR, VY, VB, AR, AY, AB
Power
Active Power W Total, WR, WY, WB
Apparent Power VA Total, VAR, VAY, VAB
Reactive Power VAR Total, VAR R, VAR Y, VAR B
Power Factor PF Avg, PFR, PFY, PFB
Energy / Integrated
Active Energy Wh
Apparent Energy VAh
Reactive Energy VARh-Ind, VARh-Cap
Load Hrs, No. of Interruption, Life Timer LH, Intr, On.Hr Ah, PF Avg
Old (Energy, Load Hrs) Old (Wh, VAh, VARh Ind/Cap, LH)
Harmonics
Voltage THD THD% VR, VY, VB
Current THD THD% AR, AY, AB
K Factor K Factor: VR, VY, VB, AR, AY, AB
Individual Harmonics Upto 31st (V & A)
Events (High/Low)/ With time stamp
Voltage VLL, VLN High/Low VLL, VLN
Current High/Low A
Frequency High/Low Hz
VA High/Low VA
W High/Low W
VAR High/Low VAR
Power Factor High/Low PF
Demand Programmable to any one of the below
Active Power (W) Watt
Apparent Power (VA) VA
Reactive Power (VAR) VAR
Current Average (A.Avg) A Avg
Suitable to measure current from mA to hundreds of kA.
High linearity | Wide range | Non-intrusive, no power drawn from the main.
Very useful with large size or awkward shaped conductors or in places with limited access.
No danger from open-circuited secondary | Not damaged by large overloads.
CT Specification
Clip CT
333 mV
Input current 250A
Rogowski coil
Rated Current: 100A ~ 100 kA
Output: 0.333V or 100mV per 1000A
Diameter: 24 cm, 36 cm
Lead wire: 1.5 m length
Isolation voltage: 3500Vo oTemperature range: -25 C + 70 C
Response bandwidth: 1Hz ~ 1MHz
INTELLIGENT
POWER FACTOR CONTROLLER
iPFC
Contact for certification details
www.elmeasure.com
INTELLIGENT DEVICE TO
MAINTAIN THE POWER FACTOR
IN REQUIRED RANGE
Current | Voltage | Frequency | PF | VAR | 6/8/12 stage control
www.powercorporation.in
PC
/IP
CF
/V6/1
017
Three phase sensing.
Intelligent Power Factor Controlling based on the capacitor
bank switching history (Number of operations, ON time)
improves the capacitor life time.
6 or 8 or 12 switching relay outputs.
Automatic or manual control (manual control with power
backup option).
User programmable:
- Star/Delta.
- Lead and Lag limits.
- PT and CT ratios.
- CT secondary.
- Minimum switch ON time (4-999 seconds).
- Minimum discharge time (4-999 seconds).
- Minimum capacitor on time (4-999 seconds).
- Minimum sensing current for controlling operation
100mA - 500mA.
- User programmable capacitor value.
Fault detection (Over compensation, Under compensation,
Over voltage, Over current, Under voltage, Under current,
Over harmonics for voltage and current).
Displays VLL, VLN, Amps (Average and Phasewise) Frequency,
W, PF, VAR(Total and Phasewise) Wh,PF Avg.
Four quadrant operation.
RS 485 communication interface (Optional).
Features:
Technical Specification:
Specification Description
Accuracy:
Sensing/
Measurement:
Input voltage:
Applications:
Advantages
In all Incomers.
Fixed power factor corrections individual (e.g. motor,
transformers, lighting, etc.)
Group fixed power factor correction (several equipments
connected in a group).
Capacitor banks of tuned and detuned.
Harmonic trap applications (e.g. UPS, Frequency Drives
and Converters, etc.)
Three phase sensing gives accurate measurement of PF.
Fault Detection (Over compensation, Under compensation,
Over voltage, Over current, Under voltage, Under Current,
Over harmonics for voltage and current).
Automatic or Manual Control (manual control with power
backup option).
Increased capacitor life - capacitor switching based on
history - ON time / number of switching.
Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel)
90 mm
90 m
m
Panel
Clamp
Mechanical Specification:
90 m
m
96 m
m
50 mm
4 Voltage inputs (VR, VY, VB, VN) Programmable 110 or 415V LL
Nominal (Range 80 to 550V LL) Primary Programmable up to
999 kV. Burden: 0.2VA Max. per phase.
Input current: Current inputs (AR, AY, AB) 50mA - 6A (Field configurable
1A or 5A). Primary Programmable up to 99 kA.
Overload: 10A max continuous, 50A max for 3 Sec.
Burden: 0.2VA Max. per phase.
Aux-Supply : (Control Power): 180 - 300V AC/DC, 40-70Hz.
Burden: 10VA Max.
Display Resolution: 1 row, 6 digits, (Integrated 6 digits) 10mm.
CT PT Ratio Max: 2000 MVA Programmable.
Communication: Master to PC.
RS485 serial channel connection, Industry standard Modbus
RTU protocol (RS232 optional).
Baud rate: 4800 bps to 19200 bps (Preferred 9600 bps).
Isolation: 2000 volts AC isolation for 1 minute between
communication and other circuits.
Contact rating: SPST, 2A @ 240V.
Weight: Unpacked: 350 gms, Packed: 450 gms.
True RMS, 1 Sec update time. 4 Quadrant Power & Energy.
NVB
VY
VR
AB
AY
AUX
AR
S1
S2
S1
S2
S1
S2
S1 S2
S1 S2
S1 S2
RY
BN
LOADRECEIVEDDELIVEREDLINE
RS
48
5
COM
1 2 3 4 5 6 7 8 9 10 11 12
LOAD
ALA
RM COM
1
Connection Scheme:
Note: Additional error of 0.1% of full scale, for meter input current below 500mA
Class 1.0 (default) as per IEC 62053-21, Class 0.5 as per
IEC 62053-22 (Optional).
Input Frequency: 45 65 Hz
ECO friendly lead free 18 months warranty
Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters
| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input
Output | Transducers | Converters
Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE
HO & Unit-I:
Plot No.: 47-P, Hardware Park, KIADB,
Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,
Bengaluru - 562149 Karnataka INDIA.
Unit-II:
Goutham Garden, No. 4, Veerapandi,
Coimbatore - 641019 Tamilnadu INDIA
T: 0422 2697200 TF: 0244 2695200
Unit-III:
#764, 4th Phase, 707, Yelahanka New Town,
Bengaluru - 560 064 Karnataka INDIA
T: +91 80 28461744
ELMEASURE INDIA PRIVATE LIMITED
SMART I/O
www.elmeasure.com
SMARTEST WAY TO CAPTURE
THE INPUT & COMMUNICATE
DATA OUTPUT!
Universal Input | Universal Output | Digital Output
SMART INPUT & OUTPUT
MODULE
www.powercorporation.in
PC
/SI-
O/V
3/1
017
Up to 8 Universal Inputs field configurable
Up to 4 Universal Outputs field configurable
6 SSR outputs and 2 relay outputs (optional)
Communication LON / RS 485
Fire resistant enclosure
Pluggable terminal blocks, for installation wiring and ease
of maintenance
UO
-CH
1
UO
-CO
M
UO
-CH
2
UO
-CH
3
UO
-CO
M
UO
-CH
4
DO
1
CO
M1
DO
2
CO
M2
DO
3
CO
M3
DO
4
CO
M4
DO
5
CO
M5
DO
6
DO
7
CO
M7-8
DO
8
AU
X2
AU
X1
CO
M
UI-
CH
8
LO
N-
LO
N+
LO
N-
LO
N+
UI-
CH
1
CO
M
UI-
CH
2
UI-
CH
3
CO
M
UI-
CH
4
UI-
CH
5
CO
M
UI-
CH
6
UI-
CH
7
CO
M6
+
GN
D
-
AUXUniversal Output
UO
1
UO
2
G OP
UO
3
UO
4
G OP
DO1+
DO2+
DO3 DO4 DO5 DO6+ + + +
DO7 DO8+ +
Digital Output
UI1
UI2
CO
M
UI3
UI4
CO
M
Universal Input
UI5
UI6
CO
M
UI7
UI8
CO
M
A B A B
12 - 36V AC/DC
G +
Wiring Diagram:
Configuration Software
Models Available UI / DI
SIO 9000 -1
SIO 9000 -2
SIO 9000 -3
8
8
8
DO
8
6
8
UO
4
2
0
SIO 9000 - 4 A 16DI 24V
SIO 9000 - 4 B 16DI PFC
Features:
Specification Description
Technical Specification:
Voltage
Consumption
Protection
13-28VAC, 50 / 60 Hz, 12-36V DC
1A max
Under voltage, over voltage (Max 40V), over current, reverse voltage
Universal Input
Digital
Voltage
Current
RTD
Thermistor
User defined
Accuracy Class
5V to 24V
0 to 5V, 0 to 10 VDC
4 to 20 mA, 0 to 20 mA factory set for loop powered
PT 100 (2 wire )
Thermistor 10K (Type 2) (Type 3 Optional)
1%+-
00.8 C+-
00.8 C+-
1%+-
Non standard 10K Potentiometer ->
temperature curve up to 60 points, user configurable transition table
up to 16 points
2/4 Universal Output (configurable only at factory)
Digital 0 or 12VDC, 60mA, RL 200 ohm
Voltage
Current
PWM
One Shot Pulse
0 to 10 VDC
4 to 20 mA, 0 to 20 mA (optional)
Configurable period 1 - 999 seconds (programmable on time and duty)
Configurable pulse width 100 ms to 1000 ms
2 - 8 SSR output (Configurable only at factory)
PWM
One Shot Pulse
Digital (Dry/Wet
Contact)
0 OR 24V @100mA
Configurable period 1 - 999 seconds
Configurable pulse width 100 ms - 1000 ms
Communication
Lon Talk TP/FT - 10
Mechanical
Enclosure Poly Carbonate
Environmental
LONMARK
CE Mark
Operating Temperature
Storage Temperature
Relative humidity
Connector
-10 °C to +55 °C
-25 °C to +70 °C
51
2 Part pluggable
5 to 95 % (Non-condensing)
Mod Bus RS 485
Isolation RS 485 - 5 KV, LON - Polarity free
Flammability class UL94-V0 (non-flammable)
Dimensions 145x90x 45(LxBXH)
Mounting DIN rail / wall mounting
Weight 300 gm
Compliance
CO2
Pressure
Sensor
CO2 Flow
Sensor
Level
Sensor
Humidity
Sensor
Occupancy
Sensor
LON
Fan
A/C Lighting
Pump
Chiller
VAV’s
Boiler
MODBUS
UI1
UI2
CO
M
UI3
UI4
CO
M
Universal Input
UI5
UI6
CO
M
UI7
UI8
CO
M
A B A B G +
AUXUniversal Output
UO
1
UO
2
G OP
UO
3
UO
4
G OP
DO1+
DO2+
DO3 DO4 DO5 DO6+ + + +
DO7 DO8+ +
Digital Output
12 - 36V AC/DC
IP
Ordering Information :
Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters
| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input
Output | Transducers | Converters
HO & Unit-I:
Plot No.: 47-P, Hardware Park, KIADB,
Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,
Bengaluru - 562149 Karnataka INDIA.
Unit-II:
Goutham Garden, No. 4, Veerapandi,
Coimbatore - 641019 Tamilnadu INDIA
T: 0422 2697200 TF: 0244 2695200
Unit-III:
#764, 4th Phase, 707, Yelahanka New Town,
Bengaluru - 560 064 Karnataka INDIA
T: +91 80 28461744
ELMEASURE INDIA PRIVATE LIMITED
Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE
18 months warranty
ECO friendly lead free 18 months warranty
POWER CORPORATION302 Mayu Tower, Nr. Shyamal Row Houses, Satellite, Ahmedabad-380015email: [email protected], [email protected], [email protected]: www.powercorporation.in Mobile: 9376181613
POWER CORPORATION302 Mayu Tower, Nr. Shyamal Row Houses, Satellite, Ahmedabad-380015email: [email protected], [email protected], [email protected]: www.powercorporation.in Mobile: 9376181613