clinical sequence file identification system39a6b12ilb7y46yglh3knb1p-wpengine.netdna-ssl.com/... ·...
TRANSCRIPT
DENTAL INSTRUMENTATION
To order call 800.841.4522 or fax 888.610.1937.Visit our website at BrasselerUSA.com
©2012 Brasseler USA. All rights reserved. Printed in the U.S. B-3498-6M-RRD-01.12
File Identification System
SS Hand Fileto WL
Extended Set
BR4C BR5C
BR6 BR7BR0 Recapitulationto WL
BR3 Does Not Reach WL(see step 7)
BR1
Basic Set
BR2 BR3 BR4 BR5
Basic set
BR0 - #25/.08 - 19 mm
BR1 - #15/.05 - 21 and 25 mm
BR2 - #25/.04 - 21 and 25 mm
BR3 - #25/.06 - 21 and 25 mm
BR4 - #35/.04 - 21 and 25 mm
BR5 - #40/.04 - 21 and 25 mm
Extended set
BR4C - #35/.02 - 21 and 25 mm
BR5C - #40/.02 - 21 and 25 mm
BR7 - #60/.02 - 21 and 25 mm
BR6 - #50/.04 - 21 and 25 mm1. Establishstraight-lineaccesstothecanalorifices.Thisisverifiedbyseeingall
orificesatoncewithoneeye(withorwithoutaclinicalmirror).2. Establishyourpreliminaryworkinglength(WL)withanapexlocator.Useafilethat
fitsfirmlyintheapicalregion(normallyahandSSfile#06to#15)whenusingtheapexlocator.IfneededverifyradiographicallywithaSShandfile#15orhigher.
3. CopiousirrigationwithNaOCl.InstrumentthecanalstoWLatleasttoa#15withSShandfilesorNiTiScoutRaCe™rotaryfiles.
4. Adjustthemotorto500-600rpm,maximizethetorqueandplacethefirstfile(BR0)intothecontra-angle.
5. AllfilesfromBR0-BR7shouldbeusedwith4gentlestrokes.Thedesiredlengthmaybeachievedbefore4strokes.Ifnotachievedin4strokes,wipethefileandrepeatuntilthedesiredlengthisachieved.
6. BR0shouldbeusedfor3mm(curvedcanals)to5mm(straightcanals)fromthefirstengagementpoint.Irrigatethecanalorificeandchangethefile.
7. FORSEVERECURVATURESUSEBR3WITH3,2and1GENTLESTROKEStoWL.IfthisWLisnotreached,considerBR4CandBR5C.
8. IRRIGATECOPIOUSLYWITHNaOClBETWEENINSTRUMENTS.9. ThesequenceendinginBR4(#35)andBR5(#40)willalwaysbeused.Depending
onthecanalanatomy(seeanatomicalchart),twoadditionalinstrumentsmayberequired-BR6(#50)andBR7(#60).
10. FinalrinsewithNaOClfollowedbyEDTA(orotherappropriateirrigatingsolution).
11. UsetheobturationmasterpointcorrespondingtothefinalapicalsizeBR4(#35),BR5(#40),BR6(#50)andBR7(#60).Completewithpassivelateralcondensation.
Clinical SEQUENCE
DENTAL INSTRUMENTATION
To order call 800.841.4522 or fax 888.610.1937.Visit our website at BrasselerUSA.com
©2012 Brasseler USA. All rights reserved. Printed in the U.S. B-3498-6M-RRD-01.12
UpperJaw
BR6 or BR7 BR6
If curved:BR4 or BR5
BR6 or BR7 B: BR4 or BR5P: BR4 or BR5
1 canal: BR6 or BR7
MBs: BR4 or BR5DB: BR4 or BR5P: BR6 or BR7
MBs: BR4 or BR5DB: BR4 or BR5P: BR6 or BR7
B: BR4 or BR5P: BR4 or BR5
1 canal: BR6 or BR7
B: BR5L: BR5
1 canal: BR6
LowerJaw
B: BR5L: BR5
1 canal: BR6
MB: BR4 or BR5ML: BR4 or BR5
D: BR6 or BR72 Ds: BR5 or BR6
MB: BR4 or BR5ML: BR4 or BR5
D: BR6 or BR72 Ds: BR5 or BR6
B: BR5L: BR5
1 canal: BR6 or BR7
B: BR5L: BR5
1 canal: BR6 or BR7
Required Minimal Apical Preparation Sizes (MAPS)
Triangular Cross Section
Electro-Polishing
Precision Safety Tip
Alternating Cutting Edges(Centering Mechanism)