climate +7 (495) 204-30-01, 8(800) 775-42-13 e-mail: info@ned...
TRANSCRIPT
Climate equipment
www.ned-russia.su+7 (495) 204-30-01, 8(800) 775-42-13E-mail: [email protected]
NED is the Russia’s leading bRand of climate equipment
We aRe engaged in designing and pRoducing equipment. We also cReate integRal engineeRing solutions foR public and industRial buildings fRom hospitals and office centeRs to plant de-paRtments and atomic poWeR stations.
NEDnew engineering discoveries
www.air-ned.com
contents:
About thE CompANy EquipmENt
central air-conditioners 22
Round channel equipment 30
Rectangular channel equipment 34
fire-fighting ventilation equipment 44
automation and process control 50
cooling equipment 68
competitive advantages 6
company’s structure 8
production 9
our suppliers 16
our quality is certified 17
guarantee commitments 18
1 2
portfolio CoNtACts
industrial buildings. Warehouses 80
trade and amusement centers 82
medical buildings 88
Residential centers. hotels 92
office centers. administrative buildings 94
sport centers 100
special facilities 104
offices in moscow 112
Representations in Russia 112
distributors 113
3 5
NEDnew engineering discoveries
www.air-ned.com
sAlEs GEoGrAphy
company’s geography 106
4
About thE CompANy
1
6
1 About the CompAny
competitive advantages
20years
the company ned has been designing, producing, and introducing the innovative climate equipment for more than 20 years.
nowadays ned is one of the leaders in the Russia’s climate-equipment market and continues expanding its engagement in Russian regions and neighboring foreign countries.
Our company is the leading technical expert in the spheres of designing, producing, mounting, and running the ventilation and air-conditioning systems. Synthesis of R&D potential and modern production facilities allows our company to maintain the leading positions in the climate solutions market for many years.
NED holding company comprises production, trade, and servicing units as well as in-house engineering elaborations center. The art of creating mighty technological solutions has always been one of the main competitive advantage of NED brand.
NED’s elaboration team comprises the leading engineers, researchers, and designers from Russia, Italy, Switzerland, Slovenia, Hungary, and Germany.
7
NEDNew Engineering Discoveries
www.air-ned.com
Competitive Advantagesour basic advantages
№1 NED is Russia’s numbeR one tRademaRk in the heat insulation equipment maRket.
Vast range of climate equipment.
consistent improvement of equipment’s consumer properties.
designing of engineering systems, drawing of project documents, and technical audit of ready projects.
competitive prices and prompt deliveries due to the production localization in Russia and broad representation network.
OuR BaSIc aDvaNTaGES:
quality management system proven by iso 9001:2011 certificates.
guarantee and post-guarantee servicing plus contract supervision.
improvement of business processes and client servicing technologies.
in some segments of produced equipment (channel ventilation systems, condensing units, ready-made control boards), the company is steadily occupying the first position in the Russian market with respect to the sales volume.
ned is within the top three leaders in the sales of air-supply plants.
in 2013, the company NED became the first producer, which designed and launched the manufacturing of water chillers in the russian market.
8
1 About the CompAny
company’s structure
VentmontaZhstRoYequipment deliveriesmountingservicing of indoor engineering systems in buildings and structuresinnovative engineering solutionsconsultation by specialists
ned tRade housesalesinformational support
TEcHNOGROuP PRODucTION cOMPaNY
elaborationproductionquality control
kin seRVice companY guarantee and other servicing
9
NEDNew Engineering Discoveries
www.air-ned.com
production
ENTIRE clIMaTE EquIPMENT
NED equipment catalogue has all elements for creating a modern climate system.
nowadays more than 7,000 item names are produced under the ned trademark.It is more than any other European climate-equipment producer has.
NED company’s plant is located in the city of Dzerzhinsky, Moscow Region. Labs and test desks used for designing and testing of our equipment are also there.
centRal aiR-conditioneRs,
Ventilation equipment foR Round channels,
Ventilation equipment foR RectangulaR channels,
fiRe-fighting Ventilation equipment,
pRocess contRol, automation, and supeRVision sYstems,
RefRigeRating equipment.
vast range of NED’s equipment allows to solve any engineering task involving the creation of ventilation and cold-supply systems for premises:
Company’s structureproductionentire climate equipment
10
1 About the CompAny
We do not just produce andsell equipment, we create integrated engineering solutions.
INTEGRaTED ENGINEERING SOluTIONS
WE aRE alWaYS clOSE
All equipment produced by the company NED is designed and tested in the labs with the help of test desks located at our plant in the city of Dzerzhinsky, Moscow Region.
While manufacturing our equipment, we use component parts by the best russian and global manufacturers: Ziehl-Abegg AG, Klingenburg, tehnoklima, and siemens.
Such combination of R&D potential and production facilities allows us to reach the utmost perfect proportion between the modern state-of-the-art technologies used for creating our equipment and the price of the latter.
Employees of the company NED are ready to render assistance while selecting equipment and efficient engineering solutions at:
designing
equipment delivery
ventilation system mounting
air conditioning
cold supply
automation
and process control.
The company NED has the staff of first class engineers and managers at the production facilities, in the central office, and in subsidiaries and representations open in some Russia’s big cities and in the CIS countries.
Our company’s operation is based upon the integrated and careful approach to the wishes of our customers and non-stop engineering maintenance at all stages from equipment selection, delivery, and project-solution implementation to servicing.
NED possesses the entire range of equipment and services for supporting any climate solutions.
ned’s best specialists will provide consultations at the creation, selection, feasibility studies, installation, and running of the equipment.
standard commercial offers will be prepared in response to your request within 24 hours.
guarantee servicing periods for ned equipment are the longest in the industry.
11
NEDNew Engineering Discoveries
www.air-ned.com
NED’s sales system is built in a way that both managers and engineers take part in choosing the equipment for any client. As a result, clients receive not only the optimum price offer but professionally substantiated resolution of the set engineering tasks.
Our sales method is based on the integrated and attentive approach to the client’s wishes at all project stages: equipment selection, delivery, project-solution implementation, equipment operation. Consultations by the NED’s best specialists are available to the clients at each of those stages. Company’s engineers are ready to render assistance in equipment selection, feasibility studies preparation, installation, and servicing of any climate equipment.
first class engineers and managers work at subsidiaries and representations open in russia’s big cities and the Cis countries. After addressing any NED unit, our client will receive a standard commercial offer within 24 hours.
WEll DEvElOPED SalES SYSTEM
Our company has created an efficient system of sales and technical support.
24hours
eighty percent of product positions are always at the warehouses and may be shipped within 24 hours.
big plants are assembled within four weeks.
all equipment is delivered at the shortest notice. for big size deliveries, our company elaborates special logistic schemes.
NED’s clients may count upon the utmost prompt servicing:
ned servicing center carries out technical and guarantee servicing within the shortest period of time.
productionintegrated engineering solutionsWe are always closeWell developed sales system
12
1 About the CompAny
TERRITORY Of INNOvaTIONS
trumpf, Germany
Eckold, Germany
fanuc, Japan
Nitto KohKi Co, Japan
tecna, italy
oXyWElD sNC, italy
shutung machinery, taiwan
Cpiro iNtErNAtioNAl sA, sweden
Corelocker Combite, switzerland
smA mAChiNEs, spain
MacHINE TOOlS aND PRODucTION lINES
13
NEDNew Engineering Discoveries
www.air-ned.com
productionterritory of innovationsmachine tools and production lines
NED is an example of newly created successful modern high technology production in Russia.
We constantly invest in the development of in-house research department and consistently improve our equipment and production processes.
Due to the territorial localization of our production, we may offer the most competitive prices to our clients.
INNOvaTIONS IS OuR TOP PRIORITY
14
1 About the CompAny
qualITY SYSTEM
Innovative project solutions based on the global experience and international standards.
automated design process with the use of 3-D models.
15
NEDNew Engineering Discoveries
www.air-ned.com
Highest class supplies and component parts.
Precision automatic metal working lines.
Impeccable production culture and the newest precision equipment.
quality control at all production stages.
quality management system confirmed by GOST R ISO 9001:2011 certificates.
productionquality system
16
1 About the CompAny
ouR supplieRs
the use of supplies and component parts by well-known Russian and global producers is an important factor providing for the high quality of ned’s equipment
< SIEMENS controllers
< caREl controllers, steam generators
< ZIEHl-aBEGG aG GERMaNY motors and impellers
< DaNfOSS frequency transducers
< vIlMaNN gauges, electric motors, servo drives
< aROSIO aluminum shapes
< TEHNOKlIMa heat exchangers
< IRca heating coils
< DaB pumps
< ESBE servo drives and three way valves
< KlINGENBuRG regenerators
< PaNaSONIc compressors
< lG compressors
< aBB automatic equipment
< ScHNEIDER ElEcTRIc automatic equipment
< ElcO EP logic devices
17
NEDNew Engineering Discoveries
www.air-ned.com
NED equipment has CE labeling, which proves its conformity to the European standards including 2004/108/EC, 2006/95/EC, and 2006/42/EC directives related to electromagnetic compatibility; electric safety; and safety while producing, assembling, installing, and outer supervising.
In Russia, equipment with NED trademark has special certificates for installation in medical institutions, at atomic energy enterprises, and oil-and-gas facilities (Gazprom certificate).
our quality is certified
The quality-management system is certified in accordance with GOST R ISO 9001:2011.
our suppliersour quality is CertifiedGuarantee Commitments
guarantee commitments
Guarantee commitments are met in the following cases:
all products under the NED trademark are subject to the following guarantee commitments:
STaNDaRD GuaRaNTEE cOMMITMENTS: 3 yEars uPON SalE;
ExPaNDED GuaRaNTEE cOMMITMENTS: 5 yEars uPON SalE.
defects of material;
functional defects;
defects originated at production.
18
1 About the CompAny
To apply the expanded guarantee commitments, one should first need to observe the conditions within the framework of standard guarantee commitments.
Additional condition is the regular technical inspection of equipment. Such inspection should be performed twice a year: in spring (April – May) and fall (September – October).
Technical inspection may only be performed by special technicians with required skill level. They may include manufacturer’s specialists or foreign technicians who have undergone training at the manufacturer’s and are authorized for performing the technical inspection by the manufacturer.
Technical inspection results should be registered in the product passport filled in by an authorized technician. Such passport should be kept within the entire period of guarantee commitments.
5years
GuArANtEE
cONDITIONS fOR MEETING THE ExPaNDED GuaRaNTEE cOMMITMENTS (5 yEars)
Lack of equipment’s outer damage (dents, cracks or other damages from outside).
Observance of all recommendations and instructions by the manufacturer related to the installation, hook-up, application or operation.
All works involving assembly, hook-up, start and adjustment should be carried out by persons with needed skill and respective permission for performing such works.
Only elements and components recommended by the manufacturer should be used at the installation, hook-up, adjustment, and operation.
Lack of alteration or change of equipment design not allowed by the manufacturer.
3years
GuArANtEE
cONDITIONS fOR MEETING THE STaNDaRD GuaRaNTEE cOMMITMENTS (3 yEars)
19
NEDNew Engineering Discoveries
www.air-ned.com
You may receive more information about ensuring the guarantee commitments by calling the following hot line phone number:
Guarantee commitments do not encompass the following expendable materials subject to replacement due to the regular wear and tear:
filtering insertions;
filtering fabric.
Guarantee does not cover any defects originated through buyer’s fault.
Manufacturer fails to perform the regular technical inspection at its own expense or pay for inspection performed by foreign specialists.
8 (495) 748-04-16* NED’s equipment (round channel, rectangular channel, noise insulated plants,
control units and boards, fire-fighting and smoke-removal valves, chillers of NBA and NBE series, condensing units of NSA series, detachable condensers of NNC series, and detachable water duties of NST series) is covered by:
the standard guarantee (3 years upon sale); the expanded guarantee (5 years, possible if special conditions are observed).
Guarantee period for other equipment is 12 months.
Guarantee commitments
EquipmEnt
2
22
EquipmEnt2
Broad family of functional units allows to create any possible air processing schemes for resolving the ventilation and air conditioning tasks.
Sectional design of the plant on the basis of separate units allows the designer to quickly and easily select any required configuration.
Plant may be manufactured in indoor, outdoor, northern or medical versions.
Central Air Conditioners
Our plants comprise 25 mm thick light sandwich panels of foamed polyurethane, which efficiently reduce noise and heat loss and attach more durability and rigidity to the body.
Well considered and practical design of our plants ensures easy and comfortable installation and servicing, universal package of sections along the servicing side, possibility to remove all sections, mounting both in floor-standing and suspended versions through the transformations of legs into cantilevers for suspending without application of additional parts.
Easy connection with the air-duct system is performed with the help of butt panels installed on any end blocks of the system.
Automatics kit (control units, gauges, valves, drives, etc.) is offered for any plant. It provides for reliable protection, precise operation, and flexible control.
Quick standard size selection
Air-supply plants with cooling, with heat recovery
Air-supply plants with heating
Exhaust plants
100-50
90-50
80-50
70-40
60-35
60-30
50-30
50-25
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000
LITENED Central Air Conditioners
23
Central air Conditioners
NEDnew engineering discoveries
www.air-ned.com
Plants with heat recuperation (efficiency factor up to 85%).
Detachable panel is anchored on the body with the help of special aluminum shape.
25 mm
25 mm thick sandwich panels consist of two galvanized steel sheets with light foamed polyurethane filler. Efficient noise and heat-loss reduction plus increased durability and rigidity of the sections’ body.
Mounting is possible both in floor-standing and suspended position due to the universal design of the anchorage.
24
EquipmEnt2
AIRNED M-45
AIRNED M-40
AIRNED M-35
AIRNED M-30
AIRNED M-25
AIRNED M-20
AIRNED M-12
AIRNED M-8
AIRNED M-7
AIRNED M-6
20000 40000 60000 80000 100000 120000 140000
Broad family of functional units allows to create any possible air-processing schemes for resolving the ventilation and air conditioning tasks.
Sectional design of the plant allows the designer to quickly and easily select any required configuration.
Plant may be manufactured in indoor, outdoor or medical versions.
Plant may be built both of singular and mono-block combined sections, which reduces the price, size, and weight of the plant and simplifies its mounting.
Plant’s unique code yielded automatically in the process of software analysis allows to explicitly identify an itemized configuration of the plant.
Our plants comprise 45 mm thick light foamed polyurethane sandwich panels, which efficiently reduce noise and heat losses and attach more durability and rigidity to the body.
Easy and simple servicing is ensured due to detachable service panels furnished with handles and anchored on the body by clips.
Automatics kit (control units, gauges, valves, drives, etc.) is offered for any plant. It provides for reliable protection, precise operation, and flexible control.
AIRNED-M Central Air Conditioners
Quick standard size selection
Air-supply plants with cooling
Air-supply plants with heating, with heat recovery
Exhaust plants
25
Central air Conditioners
NEDnew engineering discoveries
www.air-ned.com
Design rigidity is ensured due to the durable aluminum shape connected by plastic angle elements.
45 mm thick sandwich panels consist of two galvanized steel sheets with light foamed polyurethane filler. Efficient noise and heat loss reduction plus increased durability and rigidity of the sections’ body.
Carriage frame has special orifices for transportation and easy mounting.
Detachable service panels are furnished with plastic handles.
Plants with heat recuperation (efficiency factor up to 85%).
45 mm
26
EquipmEnt2
Central air conditioners of medical version are applied when there are special requirements to the air purification quality in medical institutions, pharmaceutical factories, and other facilities.
Such conditioners are represented by 8 standard sizes in MED (LITENED) version and 10 standard sizes, in MED (AIRNED) version, with capacity from 500 m3/hour to 150,000 m3/hour.
Such conditioners are manufactured in two modifications:
with inner elements of galvanized steel,
with inner elements of stainless steel.
Fans’ sections are furnished with polycarbonate inspection windows and backlights.
To ensure the non-stop operation of ventilation plant, it is possible to manufacture LITENED and AIRNED ventilation sections with stand-by motors.
Basic operational motor is connected through the V-belt drive with the stand-by motor on the shaft of which an impeller is installed. In case of belt rupture or basic motor’s failure, the automatic system – with the help of differential-pressure transducer – will switch the feeding from the basic motor to the stand-by one.
In most of cases, the compact allocation of stand-by motor allows not to increase the sizes of the fan section and, consequently, the plant as a whole.
Original design allows to replace the failed motor within the shortest possible time.
Medical Version of Central Air Conditioners
Fan Sections with Stand-By Motors
27
Central air Conditioners
NEDnew engineering discoveries
www.air-ned.com
It is possible to manufacture any LITENED and AIRNED plants configurations in outdoor version.
For protection from atmospheric precipitations, the plant has a roof of galvanized steel sheet.
Air intake screen furnished with steel grid is installed from environmental air side.
In LITENED plants of outdoor version, the vent with drive is located in the air-intake section.
In AIRNED plants of outdoor version, the drive of air vent is closed with the help of casing made of galvanized steel sheet.
Outdoor Version of Central Air Conditioners
Plants of northern version are furnished with heat insulated air vents.
Heat insulated vents may be installed on AIRNED plants of all standard sizes and on LITENED plants of 50-30 standard size and higher.
Vent body is made of galvanized steel sheet and rotary blades, of aluminum shape.
Tubular heating coils are located in the places of blades attachment and rule out the possibility of their freezing to the vent’s body or to each other.
Connecting terminals of heating coils are withdrawn to the junction box, which is located on the side surface of the vent’s body. Protection degree of the junction box is IP54.
Northern Version of Central Air Conditioners
28
EquipmEnt2
Air capacity from 1,000 to 200,000 m3/hour.
Resolution of any non-standard tasks in the spheres of ventilation and air conditioning.
Load-carrying frame comprises the shapes of stainless aluminum alloy. Sandwich panels may have the outside layers of galvanized steel, plasticized galvanized sheet steel, Peraluman alloy, stainless steel. Foamed polyurethane or mineral wool may be used as filler.
To connect panels in the frame, we use specially patented locking system, which provides for high durability (up to 2,500 Pa) of 25, 50 or 60 mm thick three-layer sandwich panels due to the pressure uniformity along the entire perimeter.
Carriage frame is made of galvanized rolled-formed sections assembled with the help of bolts or welded in accordance with the unit configuration. Frame’s design allows to lay water and draining pipes. Upon request, the basements and supporting structures may have different shape and size or may be made of different materials.
Air conditioner sections, which require regular inspection and servicing (filters, fans, etc.) are furnished with comfortable doors with additional options: safety grid, embedded limit switch of fan sections, twin-chamber inspection windows, backlight, switchboard, etc.
Broad family of filters: coal, rotary (drum), electrostatic precipitators, absolute (up to H14), bactericide lamps, metal filters for air with oil-vapor admixtures. Furnished with moisture separator and drain pan in special cases.
Rotary filtration system allows to maintain the constant air volume in the operating plant irrespective of filtering material pollution.
Highly efficient copper-aluminum tubular heat exchangers with the number of rows from 1 to 12 allow to easily choose a heating or cooling section with required thermal capacity. Design versions: with steel or stainless steel pipes destined for hot water; vapor heat exchangers with ribbing of painted aluminum, copper, tin, stainless steel.
Twin channel multi-zonal sections are furnished with both heater and cooler, which allows two separate air ducts to convey warm and cold air simultaneously in adequate volume and at required temperature.
Moistening by compressed air or water under pressure ensures high adiabatic efficiency (up to 98%) and reduces operation costs. All sectional components (body, pan, cantilevers, moisture separator) are made of stainless steel with prefabricated and ready-for-use self-cleaning nozzles.
Ultrasonic moistening sections disperse the surface waves of treated water in the form of fine foggy particles due to the cavitation effect. Such air moistening scheme allows to save electricity, reduces the hook-up cost, and extends the service life of equipment.
Fan sections of centrifugal type with double-side intake in the body of galvanized steel (minimum operating time is 20 000 hours). Statically and dynamically balanced impeller may have blades bent both forward or backward.
Produced in Italy.
POWERNED Central Air Conditioners
29
Central air Conditioners
NEDnew engineering discoveries
www.air-ned.com
Quick standard size selection
16243648647686
108130150180230260320
360400430500560600800
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15Air consumption 103 m3 /hour
Air consumption 103 m3 /hour
Air consumption 103 m3 /hour
Air consumption 103 m3 /hour
10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
30 34 38 42 46 50 54 58 62 66 70 74 78 82 86 90 94 98
Standard size 16 24 36 48 64 76 86 108 130 150 180
Width, mm 864 864 1114 1364 1364 1364 1364 1614 1614 1864 2114
Height, mm 614 864 864 864 994 1114 1364 1364 1614 1614 1614
Frame height, mm 100 100 100 100 100 100 100 100 100 100 100
Standard size 230 260 320 360 400 430 500 560 600 800
Width, mm 2114 2364 2364 2614 2864 3114 2114 3364 3614 3864
Height, mm 1864 1864 2114 2114 2114 2114 2364 2364 2364 2614
Frame height, mm 100 150 150 150 150 150 200 200 200 200
10 20 30 40 50 60 70 80 90 100
3500
3000
2500
2000
1500
1000
500
0
Tota
l pre
ssur
e, P
a
Application sphere
30
EquipmEnt2
Compact design, low acoustic characteristics, and esthetic appearance allow to mount the equipment both in special concealed recessions and inside the serviced premises.
Sectional design of the plant allows the designer to quickly and easily select the required configuration.
Round Channel Equipment
All elements are easily embedded in the round-shape air duct system and require no additional room for allocation.
No special joint pressurization arrangements are needed while connecting the majority of elements to round air ducts, because our equipment has been preliminarily furnished with nipple gasket rings.
Equipment for Round Channels Automatics kit providing for reliable protection, precise operation, and flexible control is offered for any plant (control units, gauges, valves, drives, etc.)
31
Round Channel equipment
NEDnew engineering discoveries
www.air-ned.com
Air-supply plants with water heating
Air-supply plants with electric heating
Exhaust plants
Quick standard size selection
315
250
200
160
125
100
100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700
32
EquipmEnt2
TYPE
KEA 100/0,5 KEA 160/3 KEA 250/12
KEA 100/2 KEA 160/4,5 KEA 250/15
KEA 100/1,5 KEA 160/6 KEA 315/6
KEA 100/2,5 KEA 200/3 KEA 315/9
KEA 125/1,5 KEA 200/6 KEA 315/12
KEA 125/2 KEA 200/9 KEA 315/15
KEA 125/2,5 KEA 200/12 KEA 315/18
KEA 125/3 KEA 250/6
KEA 160/2 KEA 250/9
TYPE
KWH 160/2
KWH 200/2
KWH 250/2
KWH 315/2
Body and switch box of galvanized steel sheet. Heating coils of stainless steel. Body and air are protected from overheating with two thermostats and heat contacts circuit. Operating range of passing air temperatures is from – 40 to + 40°C.
Body of durable light high quality plastic. Motor-in-wheel with blades bent backwards. Single-phase asynchronous motors are protected from overheating by heat contacts with automatic restart. Endurance of 40 000 hours.
Destined for handy and easy mounting of big ventilation system’s elements and for preventing the conveyance of vibration from fan to air duct. Made of galvanized steel sheet with insulating filler layer. Tied with two bolts.
KVR centrifugal fans
HTK quick-split clamps
Two-line design. Body of galvanized steel sheet. Heat exchange surface of aluminum plates and copper tubes passing through them. Maximum temperature of heat-transfer agent is + 170°C. Maximum operating pressure is 1.5 MPa.
Wall-mounted or ceiling-mounted anchorage of KVR fans. Made of galvanized steel sheet.
KWH water heaters
KKV fan anchoring cantilevers
KEA electric heaters
TYPE
KKV 100
KKV 125
KKV 160
KKV 200
KKV 250
KKV 315
TYPE
KVR 100/1
KVR 125/1
KVR 160/1
KVR 200/1
KVR 250/1
KVR 315/1
TYPE
HTK 100
HTK 125
HTK 160
HTK 200
HTK 250
HTK 315
33
Round Channel equipment
NEDnew engineering discoveries
www.air-ned.com
TYPE
KFC 100
KFC 125
KFC 160
KFC 200
KFC 250
KFC 315
TYPE
KVC 100
KVC 125
KVC 160
KVC 200
KVC 250
KVC 315
TYPE
КОN 100
КОN 125
КОN 160
КОN 200
КОN 250
КОN 315
TYPE
KCH 100
KCH 125
KCH 160
KCH 200
KCH 250
KCH 315
PP pad under drive
TYPE
KNK 100/6 KNK 200/6
KNK 100/9 KNK 200/9
KNK 125/6 KNK 250/6
KNK 125/9 KNK 250/9
KNK 160/6 KNK 315/9
KNK 160/9 KNK 315/6
Filter body and cover of galvanized steel sheet. Special anchorage on removable cover for easy replacement and dismantling of filtering insertion. Destined for operation with KVC filtering insertions.
Body and rotary plate of galvanized steel sheet. Pressurizing rubber gasket on the rim of rotary plate. Complete set comprises square pivoting rod with side of 8 mm and manual drive with locker of opening angle.
Body and inner perforated cylinder of galvanized steel sheet. Noise attenuating material – mineral wool. Two types differing by the length of noise attenuating section: 600 mm and 900 mm.
Designed for KFC cartridge filters. Filtering material – synthetic fiber of EU3 purification category.
Body of galvanized steel sheet. Two one-side spring-assisted blades of aluminum sheet are embedded inside the valve.
KFC cartridge filters
KCH control valves
KNK mufflers
KVC cartridge insertions
KON check valves
34
EquipmEnt2
Rectangular Channel Equipment
Broad variety of air processing schemes allows to solve any tasks involving ventilation and air conditioning.
Sectional design of the plants allows the designer to quickly and easily select any required configuration.
All elements are easily embedded in the rectangular air-duct system and require no additional room for allocation.
Automatics kit providing for reliable protection and control is offered for any plant (control units, gauges, valves, drives, etc.)
Endurance over 40 000 hours.
35
RectangulaR channel equipment
NEDnew engineering Discoveries
www.air-ned.com
Air-supply plants with coolingAir-supply plants with water heatingAir-supply plants with electric heatingExhaust plants
100-50
90-50
80-50
70-40
60-35
60-30
50-30
50-25
40-20
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000
Quick standard size selection
36
EquipmEnt2
TYPE
VR 40-20/20-4D VR 60-35/31-6D
VR 40-20/20-4E VR 70-40/35-4D
VR 50-25/22-4D VR 70-40/35-6D
VR 50-25/22-4E VR 70-40/35-8D
VR 50-25/22-6D VR 80-50/40-4D
VR 50-30/25-4D VR 80-50/40-6D
VR 50-30/25-4E VR 80-50/40-8D
VR 50-30/25-6D VR 90-50/45-4D
VR 60-30/28-4D VR 90-50/45-6D
VR 60-30/28-4E VR 90-50/45-8D
VR 60-30/28-6D VR 100-50/63-4D
VR 60-35/31-4D
TYPE
EA 30-15/3 EA 60-35/30
EA 30-15/4,5 EA 70-40/15
EA 40-20/6 EA 70-40/30
EA 40-20/12 EA 70-40/45
EA 50-25/7,5 EA 70-40/60
EA 50-25/15 EA 80-50/15
EA 50-25/22,5 EA 80-50/30
EA 50-30/7,5 EA 80-50/45
EA 50-30/15 EA 80-50/60
EA 50-30/22,5 EA 90-50/30
EA 60-30/15 EA 90-50/45
EA 60-30/22,5 EA 90-50/60
EA 60-30/30 EA 100-50/45
EA 60-35/15 EA 100-50/60
EA 60-35/22,5
Fan’s body and impeller are made of galvanized steel sheet. Motor-in-wheel with blades bent forward (standard sizes from 40-20 to 90-50) or “free” impeller with blades bent backward (standard size 100-50). Single-phase and three-phase asynchronous electric motors are protected from overheating with the help of embedded heat contacts with remote circuit terminals. Over 40 000 hours of endurance.
Body and switch box of galvanized steel sheet. Heating coils of stainless steel. Body and air are protected from overheating with the help of two thermostats and heat contacts circuit. Operating range of passing air temperatures is from – 40 to + 40°C.
VR fans
EA electric heaters
TYPE
VRN 40-20/18.2D VRN 70-40/31.2DM
VRN 50-25/22.2D VRN 70-40/31.2D
VRN 50-25/20.2D VRN 80-50/35.2D
VRN 50-30/25.2D VRN 80-50/40.4D
VRN 50-30/22.2D VRN 90-50/40.2D
VRN 60-30/28.2D VRN 90-50/35.2D
VRN 60-30/25.2D VRN 90-50/40.4D
VRN 60-35/31.2D VRN 100-50/40.2D
VRN 60-35/28.2D VRN 100-50/45.4D
VRN 70-40/35.2D
Fan’s body is made of galvanized steel sheet and has removable service cover. Durable and light “free” impeller with backward bent blades of polyamide reinforced with glass fiber is installed directly on electric motor’s shaft. Three-phase asynchronous electric motors are protected from overheating with the help of embedded heat contacts with remote circuit terminals. Insulation category is IP 54.
VRN fans
37
RectangulaR channel equipment
NEDnew engineering Discoveries
www.air-ned.com
TYPE
WH 30-15/2 WH 60-35/2
WH 30-15/3 WH 60-35/3
WH 40-20/2 WH 70-40/2
WH 40-20/3 WH 70-40/3
WH 50-25/2 WH 80-50/2
WH 50-25/3 WH 80-50/3
WH 50-30/2 WH 90-50/2
WH 50-30/3 WH 90-50/3
WH 60-30/2 WH 100-50/2
WH 60-30/3 WH 100-50/3
TYPE
RW 40-20 RW 70-40
RW 50-25 RW 80-50
RW 50-30 RW 90-50
RW 60-30 RW 100-50
RW 60-35
TYPE
RF 40-20 RF 70-40
RF 50-25 RF 80-50
RF 50-30 RF 90-50
RF 60-30 RF 100-50
RF 60-35
Two-line and three-line design. Body of galvanized steel sheet. Heat exchange surface of aluminum plates and copper tubes passing through them. Maximum temperature of heat-transfer agent is + 170°C. Maximum operating pressure is 1.5 MPa.
Three-line design. Body of galvanized steel sheet. Heat exchange surface of aluminum plates and copper tubes passing through them. Standard complete set comprises shaped plastic drop catcher and pan with flange for collecting and draining the condensate. Maximum operating pressure of refrigerant is 1.5 MPa.
Three-line single-loop design. Body of galvanized steel sheet. Heat exchange surface of aluminum plates and copper tubes passing through them. Standard complete set comprises shaped plastic drop catcher and pan with flange for collecting and draining the condensate. As necessary, complete set may additionally comprise the capillary thermostat engaged in anti-freezing protection.
WH water heaters
RW water coolers
RF Freon coolers
250
200
150
100
50
0
Aerodynamic characteristics of heat exchangers
RW
RF
I WH/2II WH/3 (КрОме 100-50)III WH 100-50/3
Поте
ря д
авле
ния,
Па
Air flow velocity, m/sec 0 1 2 3 4 5 6
II
III
I
38
EquipmEnt2
TYPE
FRC 30-15 FRC 60-35
FRC 40-20 FRC 70-40
FRC 50-25 FRC 80-50
FRC 50-30 FRC 90-50
FRC 60-30 FRC 100-50
Filter body and cover of galvanized steel sheet. Special anchorage on removable cover for easy replacement and dismantling of filtering insertion. Designed for the operation with DFC filtering insertions. DFC filtering insertions are not included in the complete set.
FRC cartridge filters
Aerodynamic characteristics of FRC cartridge filters
Поте
ря д
авле
ния,
Па 350
300
250
200
150
100
50
0
0 1 2 3 4 5 6Air flow velocity, m/sec
I 30-15, 40-20II 50-25, 50-30, 60-30, 60-35III 70-40, 80-50, 90-50,100-50
I
II
III
TYPE
DFC 30-15 DFC 60-35
DFC 40-20 DFC 70-40
DFC 50-25 DFC 80-50
DFC 50-30 DFC 90-50
DFC 60-30 DFC 100-50
Designed for FRC cartridge filters. Body of galvanized steel sheet. Filtering material of synthetic fiber with EU3 purification category is fixed on the galvanized steel grid.
DFC filtering insertions
TYPE
FRP 30-15 FRP 60-35
FRP 40-20 FRP 70-40
FRP 50-25 FRP 80-50
FRP 50-30 FRP 90-50
FRP 60-30 FRP 100-50
Filter’s body and cover of galvanized steel sheet. Special anchorage on removable cover for easy replacement and dismantling of filtering insertion. Designed for operation with DFP filtering insertions. DFP filtering insertions are not included in the complete set.
FRP pocket filters
Aerodynamic characteristics of FRP pocket filters
I FRP (EU 7)II FRP (EU 5)III FRP (EU 3)
II
III
500
400
300
200
100
0
Поте
ря д
авле
ния,
Па
Air flow velocity, m/sec 0 1 2 3 4 5 6
I
39
RectangulaR channel equipment
NEDnew engineering Discoveries
www.air-ned.com
TYPE
DFP 30-15 G3 DFP 50-30 F5 DFP 70-40 F7
DFP 30-15 F5 DFP 50-30 F7 DFP 80-50 G3
DFP 30-15 F7 DFP 60-30 G3 DFP 80-50 F5
DFP 40-20 G3 DFP 60-30 F5 DFP 80-50 F7
DFP 40-20 F5 DFP 60-30 F7 DFP 90-50 G3
DFP 40-20 F7 DFP 60-35 G3 DFP 90-50 F5
DFP 50-25 G3 DFP 60-35 F5 DFP 90-50 F7
DFP 50-25 F5 DFP 60-35 F7 DFP 100-50 G3
DFP 50-25 F7 DFP 70-40 G3 DFP 100-50 F5
DFP 50-30 G3 DFP 70-40 F5 DFP 100-50 F7
Designed for FRP pocket filters. Filtering material of synthetic fiber with EU3÷EU9 purification category is fixed on the steel frame in the form of pockets.
DFP pocket filtering insertions
TYPE
FRU 30-15 FRU 60-35
FRU 40-20 FRU 70-40
FRU 50-25 FRU 80-50
FRU 50-30 FRU 90-50
FRU 60-30 FRU 100-50
Filter body and cover of galvanized steel sheet. Special anchorage on removable cover for easy replacement and dismantling of filtering insertion. Designed for the operation with DFU filtering insertions. DFU filtering insertions are not included in the complete set.
FRU shortcut pocket filters
TYPE
DFU 30-15 G3 DFU 60-35 G3
DFU 40-20 G3 DFU 70-40 G3
DFU 50-25 G3 DFU 80-50 G3
DFU 50-30 G3 DFU 90-50 G3
DFU 60-30 G3 DFU 100-50 G3
Designed for FRU pocket filters. Filtering material of synthetic fiber with EU3 purification category is fixed on the steel frame in the form of pockets.
DFU shortcut filtering insertions
Aerodynamic characteristics of FRU pocket filters
I FRU (30-15, 40-20)II FRU (50-25, 50-30, 60-30, 60-35, 70-40, 80-50, 90-50, 100-50)
180
150
120
90
60
30
0
Поте
ря д
авле
ния,
Па
Air flow velocity, m/sec 0 1 2 3 4 5 6
40
EquipmEnt2
Aerodynamic characteristics of NK mufflers
160
140
120
100
80
60
40
20
0
Поте
ря д
авле
ния,
Па
Air flow velocity, m/sec 0 1 2 3 4 5 6
I 30-15, 50-25, 50-30II 70-40, 90-50III 40-20, 60-30, 60-35, 80-50, 100-50
I
II
III
TYPE
NK 30-15 NK 60-35
NK 40-20 NK 70-40
NK 50-25 NK 80-50
NK 50-30 NK 90-50
NK 60-30 NK 100-50
Body of galvanized steel sheet. Noise-absorbing plates of noncombustible basalt fiber mineral wool upholstered with felt for preventing the particles blowing.
NK mufflers
TYPE
REC 40-20 REC 70-40
REC 50-25 REC 80-50
REC 50-30 REC 90-50
REC 60-30 REC 100-50
REC 60-35
Efficiency of exhaust air thermal energy utilization is up to 70%. Body of galvanized steel sheet. Heat exchange surface is a pack of 0.2 mm thick specially shaped aluminum plates. Complete set comprises pan and nozzle with fastening nut for condensate draining.
REC lamellar recuperators
TYPE
LB 40-20/143 LB 60-30/190 LB 80-50/302
LB 40-20/95 LB 60-30/127 LB 80-50/206
LB 40-20/63 LB 60-30/79 LB 80-50/127
LB 40-20/32 LB 60-30/47 LB 80-50/79
LB 50-25/159 LB 60-35/222 LB 90-50/365
LB 50-25/111 LB 60-35/143 LB 90-50/238
LB 50-25/63 LB 60-35/95 LB 90-50/159
LB 50-25/32 LB 60-35/63 LB 90-50/95
LB 50-30/174 LB 70-40/270 LB 100-50/397
LB 50-30/111 LB 70-40/174 LB 100-50/270
LB 50-30/79 LB 70-40/111 LB 100-50/190
LB 50-30/47 LB 70-40/63 LB 100-50/111
Air disinfection with ultraviolet bactericide irradiation. Body of galvanized steel sheet. Complete set comprises low-pressure mercury bactericide lamps with power of 75 W and voltage of 230 V.
LB bactericide sections
41
RectangulaR channel equipment
NEDnew engineering Discoveries
www.air-ned.com
TYPE
VRK 30/22-2E VRK 63/50-4D
VRK 40/31-4D VRK 63/50-6D
VRK 40/32-4D VRK 90/56-4D
VRK 56/35-4D VRK 90/56-6D
VRK 56/35-4E VRK 90/63-6D
VRK 56/40-4D VRK 94/56-4D
VRK 56/40-4E VRK 94/63-4D
VRK 63/45-4D VRK 94/63-6D
VRK 63/45-4E VRK 100/71-6D
TYPE
FE031-4DF.0C.V7 FE050-VDF.4I.V7
FE031-4EF.0C.V7 FE056-6EF.4I.V7
FE035-4DF.0C.V7 FE056-SDF.4F.V7
FE035-4EF.0F.V7 FE056-VDF.4M.V7
FE040-4EF.2F.V7 FE063-6EF.4M.V7
FE040-VDF.2C.V7 FE063-SDF.4I.V7
FE045-4EF.4I.V7 FE063-VDF.6N.V7
FE045-VDF.4F.V7 FE071-ADF.6F.V7
FE050-4EF.4I.V7 FE071-SDF.6F.V7
FE050-6EF.4F.V7 FE080-SDF.6N.V7
FE050-SDF.4F.V7
Fan body and impeller of galvanized steel sheet. Motor-in-wheel with blades bent backwards. Single-phase and three-phase asynchronous electric motors are protected from overheating with the help of embedded heat contacts with remote circuit terminals. Over 50 000 hours of endurance. Mounted horizontally on flat-deck or slanting roofs.
Body and channel shell of galvanized steel sheet. Crescent blades of aluminum alloy produced by Ziehl-Abegg AG, Germany. Single-phase and three-phase asynchronous electric motors are protected from overheating with the help of embedded heat contacts with remote circuit terminals.
VRK roof-mounted fans
FE…F axial channel fans
TYPE
FE031-4DQ.0C.A7 FE050-6EQ.4F.A7
FE031-4EQ.0C.A7 FE050-SDQ.4F.A7
FE035-4DQ.0C.А7 FE050-VDQ.4I.A7
FE035-4EQ.0F.A7 FE056-6EQ.4I.А7
FE040-4EQ.2F.A7 FE056-SDQ.4F.A7
FE040-VDQ.2C.A7 FE056-VDQ.4M.A7
FE045-4EQ.4I.A7 FE063-6EQ.4M.A7
FE045-VDQ.4F.А7 FE063-SDQ.4I.A7
FE050-4EQ.4I.A7
Body and square wall panel of galvanized steel sheet. Crescent blades of aluminum alloy produced by Ziehl-Abegg AG, Germany. Single-phase and three-phase asynchronous electric motors are protected from overheating with the help of embedded heat contacts with remote circuit terminals.
FE…Q axial wall-mounted fans
TYPE
CHR 30-15 CHR 60-35
CHR 40-20 CHR 70-40
CHR 50-25 CHR 80-50
CHR 50-30 CHR 90-50
CHR 60-30 CHR 100-50
Body of galvanized steel sheet. Rotary plates of aluminum shape. Pressurizing rubber gasket on the rim of rotary plate. Complete set comprises square pivoting rod with side of 10 mm.
CHR control valves
42
EquipmEnt2
Prevent vibration conveyance from the fan to the air-duct grid and compensate the thermal expansion. Two flanges of galvanized sheet with vinyl tape.
FH flexible insertions
TYPE
CAP-N 60-30 H/2 CAP-N 70-40 H/2
CAP-N 60-30 H/2,5 CAP-N 70-40 H/2,5
CAP-N 60-30 H/3 CAP-N 70-40 H/3
CAP-N 60-30 H/3,5 CAP-N 70-40 H/3,5
CAP-N 60-30 H/4 CAP-N 70-40 H/4
CAP-N 60-30 H/4,5 CAP-N 70-40 H/4,5
CAP-N 60-30 H/5 CAP-N 70-40 H/5
CAP-N 60-35 H/2 CAP-N 80-50 H/2
CAP-N 60-35 H/2,5 CAP-N 80-50 H/2,5
CAP-N 60-35 H/3 CAP-N 80-50 H/3
CAP-N 60-35 H/3,5 CAP-N 80-50 H/3,5
CAP-N 60-35 H/4 CAP-N 80-50 H/4
CAP-N 60-35 H/4,5 CAP-N 80-50 H/4,5
CAP-N 60-35 H/5 CAP-N 80-50 H/5
CAP-N 70-40 H/2DM CAP-N 90-50 H/2
CAP-N 70-40 H/2,5DM CAP-N 90-50 H/2,5
CAP-N 70-40 H/3DM CAP-N 90-50 H/3
CAP-N 70-40 H/3,5DM CAP-N 90-50 H/3,5
CAP-N 70-40 H/4DM CAP-N 90-50 H/4
CAP-N 70-40 H/4,5DM CAP-N 90-50 H/4,5
CAP-N 70-40 H/5DM CAP-N 90-50 H/5
Universal prefabricated structure comprises intake grid, VRN fan, and set of slotted sections with total length from 2 to 5 m. Delivered in disassembled condition. Complete set comprises the bottom plug. May be mounted both in horizontal and upright position.
CAP-N…H air curtains without heating
TYPE
FH 40-20
FH 50-25
FH 50-30
FH 60-30
FH 60-35
FH 70-40
FH 80-50
FH 90-50
FH 100-50
43
RectangulaR channel equipment
NEDnew engineering Discoveries
www.air-ned.com
TYPE
CAP-N 60-30 W2/2 CAP-N 70-40 W2/2
CAP-N 60-30 W2/2,5 CAP-N 70-40 W2/2,5
CAP-N 60-30 W2/3 CAP-N 70-40 W2/3
CAP-N 60-30 W2/3,5 CAP-N 70-40 W2/3,5
CAP-N 60-30 W2/4 CAP-N 70-40 W2/4
CAP-N 60-30 W2/4,5 CAP-N 70-40 W2/4,5
CAP-N 60-30 W2/5 CAP-N 70-40 W2/5
CAP-N 60-35 W2/2 CAP-N 80-50 W2/2
CAP-N 60-35 W2/2,5 CAP-N 80-50 W2/2,5
CAP-N 60-35 W2/3 CAP-N 80-50 W2/3
CAP-N 60-35 W2/3,5 CAP-N 80-50 W2/3,5
CAP-N 60-35 W2/4 CAP-N 80-50 W2/4
CAP-N 60-35 W2/4,5 CAP-N 80-50 W2/4,5
CAP-N 60-35 W2/5 CAP-N 80-50 W2/5
CAP-N 70-40 W2/2DM CAP-N 90-50 W2/2
CAP-N 70-40 W2/2,5DM CAP-N 90-50 W2/2,5
CAP-N 70-40 W2/3DM CAP-N 90-50 W2/3
CAP-N 70-40 W2/3,5DM CAP-N 90-50 W2/3,5
CAP-N 70-40 W2/4DM CAP-N 90-50 W2/4
CAP-N 70-40 W2/4,5DM CAP-N 90-50 W2/4,5
CAP-N 70-40 W2/5DM CAP-N 90-50 W2/5
TYPE
CAP-N 60-30 E/2 CAP-N 70-40 E/2
CAP-N 60-30 E/2,5 CAP-N 70-40 E/2,5
CAP-N 60-30 E/3 CAP-N 70-40 E/3
CAP-N 60-30 E/3,5 CAP-N 70-40 E/3,5
CAP-N 60-30 E/4 CAP-N 70-40 E/4
CAP-N 60-30 E/4,5 CAP-N 70-40 E/4,5
CAP-N 60-30 E/5 CAP-N 70-40 E/5
CAP-N 60-35 E/2 CAP-N 80-50 E/2
CAP-N 60-35 E/2,5 CAP-N 80-50 E/2,5
CAP-N 60-35 E/3 CAP-N 80-50 E/3
CAP-N 60-35 E/3,5 CAP-N 80-50 E/3,5
CAP-N 60-35 E/4 CAP-N 80-50 E/4
CAP-N 60-35 E/4,5 CAP-N 80-50 E/4,5
CAP-N 60-35 E/5 CAP-N 80-50 E/5
CAP-N 70-40 E/2DM CAP-N 90-50 E/2
CAP-N 70-40 E/2,5DM CAP-N 90-50 E/2,5
CAP-N 70-40 E/3DM CAP-N 90-50 E/3
CAP-N 70-40 E/3,5DM CAP-N 90-50 E/3,5
CAP-N 70-40 E/4DM CAP-N 90-50 E/4
CAP-N 70-40 E/4,5DM CAP-N 90-50 E/4,5
CAP-N 70-40 E/5DM CAP-N 90-50 E/5
Universal prefabricated structure comprises intake grid, FRC cartridge fan with EU3 insertion, WH two-line water heater, VRN fan, and set of slotted sections with total length from 2 to 5 m. Delivered in disassembled condition. Complete set comprises the bottom plug. May be mounted both in horizontal and upright position.
Universal prefabricated structure comprises intake grid, FRC cartridge fan with EU3 insertion, EA electric heater, VRN fan, and set of slotted sections with total length from 2 to 5 m. Delivered in disassembled condition. Complete set comprises the bottom plug. May be mounted both in horizontal and upright position.
CAP-N…W2 air curtains with water heating
CAP-N…E air curtains with electric heating
44
EquipmEnt2
Fire-Fighting Ventilation Equipment
Prevent the propagation of fire and combustion products along air ducts, shafts, ventilation and air conditioning channels. Also used in the air-supply and exhaust anti-smoke ventilation systems.
Certified with respect to the compliance with the requirements set forth by the Federal Law # 123-FZ of June 22, 2008 “Technical Regulations Involving Fire Safety Requirements.” Equipment application should also conform to the requirements set forth by SP7,13130.2013 and SP60.13130.2012.
Fire-Fighting Valves Equipment is not subject to installation in premises of A and B blast-and-fire safety categories, in the places engaged in sucking off the explosive and fire hazardous media and systems involving the ventilation thereof.
Environmental design and allocation category: UZ according to GOST 15150-69 (environmental air temperature from – 30 to + 40°C, direct impact of atmospheric precipitations is not allowed).
Valve body is made of galvanized steel sheet. Noncombustible material is used in rotary blades of PPK-1 and PPK-1K valves. Blade of PPK-1D valve is made of galvanized steel sheet.
In PPK-1 and PPK-1K valves, the thermosetting gasket is applied along the perimeter of rotary blade. It expands at high temperatures, thus ensuring the high pressurization of closed valve.
May be mounted in any position along with allowing the free access to the drive and servicing hatches. Servicing hatches are missing at smoke-removal valves.
In some cases, it is needed to provide the air-duct direct sections upstream and downstream the valve with length no less than the blades’ span beyond the body’s limit.
45
Fire-Fighting Ventilation equipment
NEDnew engineering Discoveries
www.air-ned.com
Reference designation of the valve; Fire-resistance limit in minutes (60, 90, 120 minutes); Rated size of valve cross-section, mm (diameter for PPK-1K); Functional destination (O – normally open, Z – normally closed); Drive type (M – electromagnetic, S – electromechanical); Drive’s feeding voltage (220 – 220 V, 24 – 24 V); Availability of thermal sensor (TD) with electromagnetic drive
or electromechanical drive (T – available, X – missing); Type of valve connection (F – flange type, N – nipple type)
ppK-1K 250 O 22090 t Fm- - --- -
PPK-1K fire-fighting valves for round channels
PPK-1 fire-fighting valves for rectangular channels
Reference designation of the valve; Fire-resistance limit in minutes (60, 90, 120, 180 minutes); Rated size of valve cross-section, mm (width and height for PPK-1K); Functional destination (O – normally open, Z – normally closed); Drive type (M – electromagnetic, S – electromechanical); Drive’s feeding voltage (220 – 220 V, 24 – 24 V); Availability of thermal sensor (TD) with electromagnetic drive
or electromechanical drive (T – available, X – missing).
ppK-1 600x300 O 22090 tm- --- -
Reference designation of the valve; Rated size of valve cross-section (width and height respectively), mm; Drive type (M – electromagnetic, S – electromechanical); Drive’s feeding voltage (220 – 220 V, 24 – 24 V); Valve allocation (V – inner, N – external); Design version (S – wall-mounted, K – channel)
Smoke-removal valves
ppK-1D 600x400 S220 Vm- - --
46
EquipmEnt2
p DESign
VDKV Du
VODKV Du
VDKV2X Du
VOD Du
D DESign F DESign
VDKN DU, VDKN F DU roof-mounted smoke-removal fans with air flaring
VDKV DU, VDKV2 x DU roof-mounted smoke-removal twin fans
VODK DU roof-mounted smoke-removal axial fans
VDKV DU and VDKV2 x DU roof-mounted fans are designed for moving the air flue gas blends with temperature 400°C or 600°C during fire throughout 2 hours.
Each type is manufactured in 11 standard sizes with capacity from 3,000 m3/hour to 90,000 m3/hour and static pressure up to 2,100 Pa.
VOD DU axial fans and VODK DU roof-mounted axial fans are designed for moving the air flue gas blends with temperature 400°C or 600°C during fire throughout 2 hours.
Each type is manufactured in 7 standard sizes with capacity from 500 m3/hour to 120,000 m3/hour and static pressure up to 610 Pa.
Smoke-Removal Fans
47
Fire-Fighting Ventilation equipment
NEDnew engineering Discoveries
www.air-ned.com
Roof-mounted fans with flaring and sideway ejection are designed for moving the air flue gas blends with temperature 400°C or 600°C during fire throughout 2 hours.
Each type is manufactured in 14 standard sizes with capacity from 2,300 m3/hour to 140,000 m3/hour and static pressure up to 2,100 Pa.
Fan type Aerodynamic power index (A, B, C) Casing design (PD). (F) – upward flaring Impeller’s diameter, dm Design version (explosion-protected) Destination (smoke removal) Maximum temperature of transported medium Modification’s sequence number Environmental design Y1
VDKn 3.15 Y1400 01DuVpA ---
Fan type Impeller’s diameter, dm Design version (explosion-protected) Destination (smoke removal) Maximum temperature of transported medium Modification’s sequence number Environmental design Y1
VDKV 3,15 Y1400 01DuV --
Fan type Characteristics of aerodynamic scheme Design index (roof-mounted) Impeller’s modification (A – 4 blades, B – 6 blades) Impeller’s diameter, dm Destination (smoke removal) Maximum temperature of transported medium Number of electric motor’s terminals Environmental design Y1
VOD 21-210 Y1400 4Du6,3АК ---
48
EquipmEnt2
VDS DU wall fans are designed for moving the air flue gas blends with temperature 400°C or 600°C during fire throughout 2 hours.
Manufactured in 9 standard sizes with capacity from 1,000 m3/hour to 49,000 m3/hour and static pressure up to 1,600 Pa.
VDS DU wall smoke-removal fans
VRD 80-70 DU and VRD 280-46 DU centrifugal smoke-removal fans
VPO axial backing fansVPOK roof-mounted axial backing fans
Smoke-Removal Fans
VRD 80-70 Du VRD 280-46 DuVRD DU wall fans are designed for moving the air flue gas blends with temperature 400°C or 600°C during fire throughout 2 hours.
VRD 80-70 DU are manufactured in 8 standard sizes with capacity from 500 m3/hour to 65,000 m3/hour and static pressure up to 1,600 Pa. VRD 280-46 DU are manufactured in 6 standard sizes with capacity from 2,000 m3/hour to 42,000 m3/hour and static pressure up to 3,000 Pa.
VpO VpOKVPO axial backing fans and VPOK roof-mounted axial backing fans are designed both for backing air in the fire-safety systems and fresh air conveyance during fire and for the operation in the general ventilation systems with short air-duct grid and without such.
Manufactured in 5 standard sizes with capacity from 3,000 m3/hour to 130,000 m3/hour and static pressure up to 1,350 Pa.
49
Fire-Fighting Ventilation equipment
NEDnew engineering Discoveries
www.air-ned.com
Fan type Power index (A, B) Impeller’s diameter, dm Design version (explosion-protected) Destination (smoke removal) Maximum temperature of transported medium Modification’s number (01 – inlet fitting + heat insulated casing, 02 - heat insulated casing, 03 – inlet fitting) Position of inlet fitting in relation to outlet fitting (N – opposite, R – to the right, L – to the left) Number of electric motor’s terminals Environmental design Y1
VDKn 3.15 Y1400 01 4nDuVA - ---
VRD 6.3 Y2400 01 90RDuV80-70 - ; ;--
Fan type Characteristics of aerodynamic scheme Impeller’s diameter, dm Design version (explosion-protected) Destination (smoke removal) Maximum temperature of transported medium Modification’s number Rotation direction (R – right, L – left) Casing’s position (0°, 45°, 90°, 135°, 270°, 315°) Environmental design Y2
Fan type VPO or VPOK Input confusor Output diffusor Impeller’s modification (A, B, C, D, E, F, G) Diameter of fan’s flow area, dm Number of electric motor’s terminals Environmental design Y1 or Y2
VpO Y125D AK -- --
50
EquipmEnt2
Automatics and Process Control
Control of any ventilation and climate equipment.
Broad variety of control units and boards using component parts by leading global manufacturers (Carel, Siemens, ABB, Moeller, etc.) ensures high regulation accuracy, stability, dependability, and safety of equipment application.
Elaborated design of control units allows to allocate automatics and power elements in one and the same body.
AutomaticsBroad range of automatics elements is offered for all plants. Automatics elements are as follows: units controlling plants of different types;
control and protection devices (safety relays, smooth start devices, control boards for fans, control boards for air curtains with water and electric heating, remote control devices);
rpm governors (electronic, transformer type, frequency transducers);
Process Control Systems
temperature gauges, pressure gauges, thermostats, hydrostats, air quality gauge;
air vents drives;
mixing units;
three-way valves and drives of three-way valves;
circulating pumps.
Warehouse stock is maintained for all automatics elements, which allows to immediately complete and ship equipment.
The company NED is an official representative of Siemens in Russia. We offer the entire family of products for the systems involving the management and process control of engineering equipment in buildings.
Possibilities Integrated set of indoor engineering systems involving control of ventilation, cold supply, and heat supply; supervision of illumination switch on and switch off as well as heat and electricity supply; and fire alarm system.
Centralized power-consumption control.
Multiuser system controlling parameters inside each premises individually.
Displaying parameters at the united control room and controlling them there (operator’s automated work station).
Modular structure (full operation capacity of each controller in the automatic mode).
51
AutomAtics And Process control
NEDnew engineering discoveries
www.air-ned.com
Expansion (scalability) of systems as necessary.
Compatibility and interaction of different typologies and systems of earlier year of production protect the investment.
Easy studying of operation with dispatcher’s stations.
Customization of control units in accordance with customer’s individual requirements.
Power consumption and operation costs reduction due to the optimization of equipment operation.
Flexible remote control.
Control of several remote facilities from united control room.
Remote diagnostics, identification, and processing of alarm signals.
Transmission of alarm signals, which depends on time, system, and priority. Transfer of such signals to various computerized control stations.
Reception and transmission of only those data and work reports, which are required by the user.
Automatic message transmission from lower-level systems to the computerized control station.
Possibility to transmit data to cell phone, pager, fax machine or email.
Possibility to create archives.
Visualization of plants’ functional schemes with the possibility to control and supervise the real or preset parameters.
Plotting the equipment operation.
Possibility to connect the central computerized global-control station with two and more facilities at a time.
52
EquipmEnt2
New solution for designing the systems involving process control of big facilities
Process-control systems have been greatly developed lately. Automatics systems by various manufacturers are presented in the market. One of the most reputed and reliable manufacturers is the company “Carel.” Its products are offered by the company NED.
Functional objectives executed by Plant Visor system:
Collecting information on the state of engineering equipment from controllers installed at the local automatics boards.
Storage and display of information on equipment’s behavior over the entire period of its operation.
Informing the servicing personnel on events requiring attention via email or SMS messages.
Access to control and supervision of equipment via the Internet and local facility’s intranet, etc.
Way of operation used by Carel’s process-control system is as follows:
Control boards with controllers are installed in places where equipment is allocated. Such boards receive the information from gauges and actuators. On the basis of said information and the algorithm preset in the operation system, controller carries out the management of ventilation system or cooling machine for instance.
Controller may operate in the autonomic mode or exchange information with the Plant Visor system. The latter is a computer with special preset software.
To execute such information exchange, an additional card should be installed in the controller.
Abilities of Plant Visor system
Plant Visor Process Control Server
Depending on the set objectives, Plant Visor is delivered in two versions: with embedded sensor screen or without such. To run a device without screen, it should be connected with monitor, keyboard, and mouse.
53
AutomAtics And Process control
NEDnew engineering discoveries
www.air-ned.com
There are two modifications designed for the operation with different number of controllers:
StAnDARD – possibility to hook up and control up to 90 external devices, 1,400 variables.
HYpER – possibility to hook up and control up to 300 external devices, 3,500 variables.
the device has: RS485 embedded adapters.
Support of CAREL and Modbus protocols.
Remote access via HTTPS protocol. Inbuilt Firewall, support of VPN connections, access segregation.
Automatic identification of plugged-in devices (for Carel protocol).
plots visualization Translation of configuration parameters between similar devices.
Backup copying and data export.
Import of new standard and nonstandard devices.
Embedded tools for elaborating the user’s interface.
54
EquipmEnt2
Supply-and-exhaust plant with lamellar recuperator, water heating, and water cooling
Used for controlling the air-supply or supply-and-exhaust plants with water or electric heating, water or Freon cooling.
Designed for the operation with heat sensors having NTC 10 K characteristics.
CAREL Control Units
Supply-and-exhaust plant with electric heating, and water cooling
Type of control unit (ACW – water heating, ACE – electric heating) Type of applied controller (pCOxc2AO) Overall power of electric heaters (9, 15, 22, 30, 45, 60, 75, 90, 120, 150, 180, 240) Connection of the first fan / external control device
(1 – single-phase, 3 – three-phase) Control of first fan’s external device (may be missing) Connection of the second fan / external control device
(1 – single-phase, 3 – three-phase, 0 – missing) Control of second fan’s external device (may be missing) Control unit enhancement – weekly timer (may be missing)
ACE CR1 t1R360 R 1 -- --
Feeding of fan or frequency transducer (R)
AiR SupplY EXHAuSt lAbEling
3~380В - 30
1~220В - 10
3~380В 3~380В 33
1~220В 1~220В 11
3~380В 1~220В 31
1~220В - 1R0
1~220В 1~220В 1R1
1~220В 1~220В 1R1R
1~220В 3~380В 1R3
3~380В - 3R0
3~380В 1~220В 3R1
3~380В 1~220В 3R1R
3~380В 3~380В 3R3
3~380В 3~380В 3R3R
Premises
Premises
55
AutomAtics And Process control
NEDnew engineering discoveries
www.air-ned.com
ACE CR2 t1R3 R 1 ---
Supply-and-exhaust plant with lamellar recuperator, smooth recirculation, water heating, and water cooling
Used for controlling the air-supply or supply-and-exhaust plants with water heating, water or Freon cooling.
Designed for the operation with heat sensors having NTC 10 K characteristics.
CAREL Control Units
Supply-and-exhaust plant with rotor recuperator, water heating, and Freon cooling
Type of control unit (ACW – water heating) Type of applied controller (pCOxc2AO with expansion module) Connection of the first fan / external control device
(1 – single-phase, 3 – three-phase) Control of first fan’s external device (may be missing) Connection of the second fan / external control device
(1 – single-phase, 3 – three-phase, 0 – missing) Control of second fan’s external device (may be missing) Control unit enhancement – weekly timer (may be missing)
Feeding of fan or frequency transducer (R)
AiR SupplY EXHAuSt lAbEling
3~380В - 30
1~220В - 10
3~380В 3~380В 33
1~220В 1~220В 11
3~380В 1~220В 31
1~220В - 1R0
1~220В 1~220В 1R1
1~220В 1~220В 1R1R
1~220В 3~380В 1R3
3~380В - 3R0
3~380В 1~220В 3R1
3~380В 1~220В 3R1R
3~380В 3~380В 3R3
3~380В 3~380В 3R3R
Premises
Premises
56
EquipmEnt2
Feeding of fan or frequency transducer (R)
AiR SupplY EXHAuSt lAbEling
3~380В - 30
1~220В - 10
3~380В 3~380В 33
1~220В 1~220В 11
3~380В 1~220В 31
1~220В - 1R0
1~220В 1~220В 1R1
1~220В 1~220В 1R1R
1~220В 3~380В 1R3
3~380В - 3R0
3~380В 1~220В 3R1
3~380В 1~220В 3R1R
3~380В 3~380В 3R3
3~380В 3~380В 3R3R
Type of control unit Overall power of electric heaters (3, 9, 15, 22, 30, 45, 60, 75, 90, 120, 150, 180, 240) Connection of the first fan / external control device
(1 – single-phase, 3 – three-phase) Control of first fan’s external device (may be missing) Connection of the second fan / external control device
(1 – single-phase, 3 – three-phase, 0 – missing) Control of second fan’s external device (may be missing) Control unit enhancement – weekly timer (may be missing)
ACET Control Units
Air-supply plant with electric heating
Supply-and-exhaust plant with electric heating and recirculation on/off
ACEt 22 t1R3 R 1 ---
Used for controlling the air-supply or supply-and-exhaust plants with electric heating. Regulating functions are ensured by the application of TER-9 programmed thermostat operating in the mode of two-position governor.
Designed for the operation with heat sensors having NTC 12 kOm characteristics.
Premises
Premises
57
AutomAtics And Process control
NEDnew engineering discoveries
www.air-ned.com
Feeding of fan or frequency transducer (R)
AiR SupplY EXHAuSt lAbEling
3~380В - 30
1~220В - 10
3~380В 3~380В 33
1~220В 1~220В 11
3~380В 1~220В 31
1~220В - 1R0
1~220В 1~220В 1R1
1~220В 1~220В 1R1R
1~220В 3~380В 1R3
3~380В - 3R0
3~380В 1~220В 3R1
3~380В 1~220В 3R1R
3~380В 3~380В 3R3
3~380В 3~380В 3R3R
Supply-and-exhaust plant with water heating
Type of control unit Type of applied controller – RLU 220 Connection of the first fan / external control device
(1 – single-phase, 3 – three-phase) Control of first fan’s external device (may be missing) Connection of the second fan / external control device
(1 – single-phase, 3 – three-phase, 0 – missing) Control of second fan’s external device (may be missing) Control unit enhancement – weekly timer (may be missing)
ACW 220 Control Units
Used for controlling the air-supply or supply-and-exhaust plants with water heating and water cooling of air (or Freon cooling when F enhancement is used).
Designed for the operation with heat sensors having Ni 1000 TK5000 characteristics.
Supply-and-exhaust plant with rotor recuperator and water heating
ACW 220 tR3 R 1 ---
Premises
Premises
58
EquipmEnt2
ACW(E) 222 Control Units
Type of control unit (ACW – water heating, ACE – electric heating) Type of applied controller – RLU 222 Overall power of electric heaters (9, 15, 22, 30, 45, 60, 75, 90, 120, 150, 180, 240) Connection of the first fan / external control device
(1 – single-phase, 3 – three-phase) Control of first fan’s external device (may be missing) Connection of the second fan / external control device
(1 – single-phase, 3 – three-phase, 0 – missing) Control of second fan’s external device (may be missing) Control unit enhancement – weekly timer (may be missing)
Used for controlling the air-supply and supply-and-exhaust plants with water or electric heating and water cooling of air (or Freon cooling when F enhancement is used).
Designed for the operation with heat sensors having Ni 1000 TK5000 characteristics.
Supply-and-exhaust plant with electric heating and water cooling
Supply-and-exhaust plant with lamellar recuperator, water heating, and water cooling
ACE 222 tR360 R 1 -- --
Feeding of fan or frequency transducer (R)
AiR SupplY EXHAuSt lAbEling
3~380В - 30
1~220В - 10
3~380В 3~380В 33
1~220В 1~220В 11
3~380В 1~220В 31
1~220В - 1R0
1~220В 1~220В 1R1
1~220В 1~220В 1R1R
1~220В 3~380В 1R3
3~380В - 3R0
3~380В 1~220В 3R1
3~380В 1~220В 3R1R
3~380В 3~380В 3R3
3~380В 3~380В 3R3R
Premises
Premises
59
AutomAtics And Process control
NEDnew engineering discoveries
www.air-ned.com
ACE 236 tR360 R 1 -- --
Feeding of fan or frequency transducer (R)
AiR SupplY EXHAuSt lAbEling
3~380В - 30
1~220В - 10
3~380В 3~380В 33
1~220В 1~220В 11
3~380В 1~220В 31
1~220В - 1R0
1~220В 1~220В 1R1
1~220В 1~220В 1R1R
1~220В 3~380В 1R3
3~380В - 3R0
3~380В 1~220В 3R1
3~380В 1~220В 3R1R
3~380В 3~380В 3R3
3~380В 3~380В 3R3R
Supply-and-exhaust plant with rotor recuperator, water heating, and Freon cooling
Type of control unit (ACW – water heating, ACE – electric heating) Type of applied controller – RLU 236 Overall power of electric heaters (9, 15, 22, 30, 45, 60, 75, 90, 120, 150, 180, 240) Connection of the first fan / external control device
(1 – single-phase, 3 – three-phase) Control of first fan’s external device (may be missing) Connection of the second fan / external control device
(1 – single-phase, 3 – three-phase, 0 – missing) Control of second fan’s external device (may be missing) Control unit enhancement – weekly timer (may be missing)
ACW(E) 236 Control Units
Used for controlling the air-supply or supply-and-exhaust plants with water or electric heating and water or Freon cooling of air. It is possible to smoothly adjust the temperature while using electric heaters due to sectional connections (up to 6 stages).
Designed for the operation with heat sensors having Ni 1000 TK5000 characteristics.
Supply-and-exhaust plant with lamellar recuperator, smooth recirculation, water heating, and water cooling
Premises
Premises
60
EquipmEnt2
Comment: Digit indicating the type of fan requiring an enhancement is put before “A,” “B,” “C,” and “H”: 1 – air supply, 2 – exhaust, 3 – additional. For instance, 1A20 enhancement is related to air-supply fan and fan’s maximum current should be from 17 to 20 A.
DESIGNATION FUNCTIONS
1 Additional connection of third single-phase fan
3 Additional connection of third three-phase fan
А 0,63
Fans hook-up without heat contacts
А 1; 1,6; 2,5; 4; 6,3
А 10
А 17
А 20
А 25
B14 Connection of fans furnished with heat contacts with current from 9 to 14 A
B25 Connection of fans furnished with heat contacts with current from 15 to 25 A
C Protection of motor with thermistors
D Connection of three-phase circulating pump
F Control of twin-loop condensing unit
G Connection of single-phase circulating pump with remote heat contacts
H 25 Connection of fans’ external devices with current from 9 A to 25 A
H 32 Connection of fans’ external devices with current from 26 A to 32 A
H 50 Connection of fans’ external devices with current from 33 A to 50 A
JE Switching off the supply fan at recuperator’s freezing (electric heating)
JW Switching off the supply fan at recuperator’s freezing (water heating)
K1F14 Hook-up of heat insulated air valve with single-phase feeding and power up to 3 kW (current of 14A)
K3F15 Hook-up of heat insulated air valve with three-phase feeding and power up to 7.5 kW (current of 15A)
K3F25 Hook-up of heat insulated air valve with three-phase feeding and power up to 11 kW (current of 25A)
K3F32 Hook-up of heat insulated air valve with three-phase feeding and power up to 15 kW (current of 32A)
L Electronic rpm governor of SI-RS11 type
NA4, NA6
Connection of three-phase pump of recuperator’s glycol loop without heat contactsNA10
NA17
ND Connection of three-phase pump of recuperator’s glycol loop with remote heat contacts
RU Device controlling standby fan
S Remote alarm system involving switching on and failures
S1 Plugging in the RTF remote control unit
T Embedded weekly timer
V Connection of regenerator
Z Three-position control of heating water valve (only for ACW 222 units)
Enhancements to Control Units
61
AutomAtics And Process control
NEDnew engineering discoveries
www.air-ned.com
Applied in the units controlling the ventilation and air conditioning systems. Two series for heating and two series, for cooling. Operation in P-, PI-, and PID-regulation modes or as a differential controller. Control of the following parameters: temperature, relative/absolute humidity, pressure/pressure drop, air flow, air quality in premises, enthalpy.
Controllers
Digital Thermostat
Applied in the units controlling the ventilation systems with electric heaters. Two microprocessors, two temperature inputs, and two outputs with switching contacts. Setting parameters and measured values are displayed on LCD monitor.
Start and protection of three-phase and single-phase motors with embedded heat contacts. Thermal and electromagnetic protection from short circuit. Hook-up of several fans on one relay (series connection) provided the fans’ overall current does not exceed the relay’s rated current.
Safety RelaysTYPE
STDT 16
SET-10B
TYPE
RLU 220
RLU 222
RLU 236
Controller RLU 220 RLU 222 RLU 236
Universal inputs 4 4 5
Digital inputs 1 1 2
Analog outputs 2 2 3
Relay outputs 0 2 6
Number of regulation circuits 1 1 2
TYPE
TER-9 digital thermostat
62
EquipmEnt2
TYPE
ACV-V3 ACV-V18,5-UPP
ACV-V4-UPP ACV-V22-UPP
ACV-V7,5-UPP ACV-V30-UPP
ACV-V11-UPP ACV-V37-UPP
ACV-V15-UPP
Smooth start and protection of three-phase fans with power from 3 to 37 kW not furnished with heat contacts or thermistors (UPP embedded device). Protection from overcharge with the help of current-limiting automats.
Integrated control of industrial air-and-heat curtains. Controlling and protective components of power unit and logic scheme are allocated in one and the same body:
ACC-W – for curtains with water heater ACC-E – for curtains with electric heater.
Joint operation with ACE and ACW control units. Embedded temperature gauge for premises (Ni 1000 TK 5000).
Functions: ventilation plant’s remote switching on/off, indication of plant’s operation mode, temperature remote alteration within the range from + 5°C to + 35° (excluding ACET units), alteration of fan motor’s rotational frequency.
Fans Control Boards
Air Curtains Control Boards
Remote Control Device
Smooth start of three-phase motors with power from 4 to 37 kW. Switching the motor feeding scheme from spider to delta for reducing the inrush current. Operation only with motors of 380/660 V or 400/690 V.
Smooth Start DevicesTYPE
UPP-7,5
UPP-11
UPP-15
UPP-22
UPP-30
UPP-37
TYPE
ACC-W
ACC-E
TYPE
RTF remote control device
63
AutomAtics And Process control
NEDnew engineering discoveries
www.air-ned.com
TYPE
ACV-DU-V3 ACV-DU-V22-UPP
ACV-DU-V4 ACV-DU-V30-UPP
ACV-DU-V5 ACV-DU-V37-UPP
ACV-DU-V7,5 ACV-DU-V45-UPP
ACV-DU-V11 ACV-DU-V55-UPP
ACV-DU-V15-UPP ACV-DU-V60-UPP
ACV-DU-V18,5-UPP ACV-DU-V75-UPP
Used to actuate three-phase smoke-removal fans. Protection from short circuit is provided and ensured. Control board comprises smooth start device with power from 15 to 75 kW (UPP- type, spider – delta switching). Conforms to GOST 53325-2009 “Fire Safety Equipment. Technical Tools of Fire Safety Automatics. General Technical Requirements.”
Controlling capacity of single-phase fans through fixed voltage change (5 degrees). Manual switching with the help of relay. Hook-up of several fans on one rpm governor (series connection) provided the fans’ overall current does not exceed the governor’s rated current.
Transformer Type RPM GovernorTYPE
RE 2 G
RE 6 G
RE 7,5 G
RET 2 KTG
RET 6 KTG
RET 7,5 KTG
Governing the rotation of single-phase fans furnished with heat contacts with automatic restart through smooth alteration of voltage. Wall or concealed mounting.
Electronic RPM GovernorTYPE
RTY-1,5
RTY-2,5
Boards Controlling ACV-DU Smoke Removal Fans
Control board is designed for manual or automatic opening and closing of fire retarding valves with electromechanical drive and 220 V AC feeding and for the indication of the state of such valves.
TYPE
ACW-PPK-4
ACW-PPK-8
ACW-PPK-12
ACW-PPK-18
ACW-PPK-27
Boards Controlling ACW-PPK Fire Retarding Valves
64
EquipmEnt2
TEMPERATURE GAUGES
STK-1 channel gauge
STK-1M channel gauge
STK-2 channel gauge
STK-2M channel gauge
STK-3 channel gauge
STK-3M channel gauge
STP indoor temperature gauge
STP-3 indoor temperature gauge
STN outdoor temperature gauge
STN-3 outdoor temperature gauge
VSP immersion temperature gauge
VSP-3 immersion temperature gauge
VSN superimposed temperature gauge
VSN-3 superimposed temperature gauge
TYPE
FC-051P1K75 LCP control panel
FC-051P1K5 NEMA1-M1 kit
FC-051P2K2 NEMA1-M2 kit
FC-051P3K0 NEMA1-M3 kit
FC-051P4K0 NEMA1-M4 kit
FC-051P5K5 NEMA1-M5 kit
FC-051P7K5 NEMA1-M6 kit
FC-051P11K FC-101 control panel
FC-051P15K
FC-051P18K
FC-051P22K
FC-101P30K
FC-101P37K
FC-101P45K
Protection and control of three-phase fans’ capacity through smooth alternation of feed current frequency in electric motor. FC frequency transducers are furnished with detachable control panel and NEMA kit (protective plastic casing closing the terminal connections). Operation on the basis of PID-regulation.
Measuring the temperature of air (STK, STP, STN) or heat-transfer agent (VSP, VSN) in the systems of ventilation, air conditioning, and heating. STK-2 and STK-2M gauges have characteristics NTC 12 kOm; STK-3, STK-3M, STP-3, STN-3, VSP-3, and VSN-3, NTC 10k; and other gauges, Ni 1000 TK 5000.
Frequency RPM Governors
Temperature Gauges
Control of excessive pressure, pressure difference, and air dispersion in the systems of ventilation and air conditioning.
Differential Pressure SwitchTYPE
DPD-2
DPD-5
DPD-10
65
AutomAtics And Process control
NEDnew engineering discoveries
www.air-ned.com
TYPE
GSD 121.1E GBB 331.1E
GSD 321.1E GIB 131.1E
GDB 131.1E GIB 161.1E
GDB 161.1E GIB 331.1E
GDB 331.1E/KF GQD 121.1E
GLB 131.1E GQD 321.1E
GLB 161.1E GMA 121.1E
GLB 331.1E GMA 161.1E
GEB 131.1E GMA 321.1E
GEB 161.1E GCA 121.1E
GEB 331.1E GCA 161.1E
GBB 131.1E GCA 321.1E
GBB 161.1E
Supervision of heat-transfer agent’s temperature in the pipeline. Visual display of values.
Hydrostat is designed for adjusting and controlling the air relative humidity in offices and residential premises.
Analysis and supervision of air quality in premises plus quantitative assessment of air saturation degree by polluting gases.
Control of air vents in the systems of ventilation and air conditioning.
Superimposed Thermostat
Indoor Hydrostat
Air Quality Gauge
Air Vents Drives
TYPE
RAK-TW
TYPE
QFA 1000
TYPE
QPA 2002
Supervision of heat exchangers’ temperature for protecting them from freezing. Complete set comprises shackles for fixing the capillary tube on the section.
Capillary ThermostatsTYPE
AZT-0,6
AZT-3
AZT-6
66
EquipmEnt2
TYPE
VRG131 15-0,63 VRG131 40-25
VRG131 15-1,0 VRG131 50-40
VRG131 15-1,63 3F 50
VRG131 15-2,5 3F 65
VRG131 20-4,0 3F 80
VRG131 20-6,3 3F 100
VRG131 25-10 3F 125
VRG131 32-16
TYPE
SME 40-1,0 SMEХ 40-1,0
SME 40-1,6 SMEХ 40-1,6
SME 40-2,5 SMEX 40-2,5
SME 40-4,0 SMEX 40-4,0
SME 60-4,0 SMEХ 60-4,0
SME 60-6,3 SMEХ 60-6,3
SME 80-6,3 SMEX 80-6,3
SME 80-10,0 SMEX 80-10,0
SME 80-16,0 SMEX 80-16,0
SME 110-16,0 SMEX 110-16,0
Adjusting the capacity of water heat exchangers through modifying the temperature of conveyed heat-transfer agent with constant consumption of the latter. Component parts: three-way valve, drive of three-way valve, circulating pump, locking ball-plug valves, heating water filter, bypass with check valve and control valve, flexible connection tubes of stainless steel. Direct and inverse configuration.
Mixing Units
Used as mixing or segregating valves for heat exchangers installed in small systems of ventilation and air conditioning. External thread. Rod stroke 5.5 mm. Complete set does not comprise connecting pieces.
Applied as connecting pieces for three-way globe valves of VXP series.
Used as mixing or segregating valves for heat exchangers installed in systems of ventilation and air conditioning. Valves of rotary type with thread connection (VRG 131 series) or flanged connection (3F series).
Three-Way Globe Valves
Connecting Kits
Three-Way Rotary Valves
TYPE
VXP 45.10-0,25
VXP 45.10-0,4
TYPE
ALG 133 kit
67
AutomAtics And Process control
NEDnew engineering discoveries
www.air-ned.com
PUMP NAME CONNECTION TYPE CONNECTION KIT
VA 35/130 Thread DAB 1" nut kit
VA 65/130 Thread КDAB 1" nut kit
A 50/180 M Thread DAB 1" nut kit
A 56/180 M Thread КDAB 1" nut kit
A 80/180 M Thread DAB 1" nut kit
A 110/180 XM Thread DAB 11/4" nut kit
ВрН 120/250.40M Flange DN 40 flange kit
ВрН 60/280.50M Flange DN 50 flange kit
ВрН 120/280.50м Flange DN 50 flange kit
ВрН 150/280.50Т Flange DN 50 flange kit
ВрН 180/280.50Т Flange DN 50 flange kit
ВрН 60/340.65м Flange DN 65 flange kit
ВрН 120/340.65Т Flange DN 65 flange kit
ВрН 150/340.65Т Flange DN 65 flange kit
ВрН 180/340.65Т Flange DN 65 flange kit
ВрН 120/360.80Т Flange DN 80 flange kit
ВрН 150/360.80Т Flange DN 80 flange kit
Control of rotary valves: drives of ARA type are designed for the operation with valves of VRG 131 series and drives of ESBE 92 type, with valves of 3F series.
Control of globe valves of VXP series.
Designed for moving water and nonfreezing blends with temperature from -10°C to +110°C. Maximum admissible operation pressure of heat carrying agent is 1 MPa. Motor shaft should be located strictly horizontally while mounting.
Servo Drives for Rotary Valves
Servo Drives for Globe Valves
Circulating Pumps
TYPE
ARA663 servo drive
ARA659 servo drive
ESBE 92 servo drive
ESBE 92 P servo drive
TYPE
SSB 61
68
EquipmEnt2
Refrigerating Equipment
COn
DEn
Sin
g
un
it m
OD
El
Refr
iger
atin
g
capa
city*
Pow
er c
onsu
mpt
ion
Leng
th
Wid
th
Heig
ht
Tran
spor
tatio
n m
ass
kW kW mm mm mm kg
5 5,9 1,33
855 404 727
92
7 7,3 1,7 112
8 8,8 2 116
10 11,5 2,7
980 420
1377127
12 14 3,2 136
15 17,3 4,2
1540
155
18 20,8 4,9 162
20 23,1 5,3 163
24 27,9 6,45
1655 930 1125
240
28 27,6 7,3 260
30 31,4 8 263
35 41,2 9,55 283
40 45,8 10,6 300
45 51 12,6 1655 930 2015 461
55 62 16,381425
1150
2000
471
60 68 17,81 474
71D 81 21,521800
562
80D 92 24,06 597
90D 101 27,97 2000
2005
730
108D 122 32,83
2700
935
121D 136 35,35 950
139D 159 43,15 1025
156D 178 49,36 1255
177D 201 53,86 2780 1320
206D 228 62,81 3105 1340
NSA 5-206D Condensing Units
Condensing units are designed for the preparation of Freon refrigerant conveyed to the heat exchanger of inner unit or to the section of direct evaporation in the air conditioning system. Non-reversing singe-loop and twin-loop condensing units of NSA type with axial fans and scroll compressors in 25 standard sizes with capacity from 5.9 to 228 kW. Outdoor design version of units. Applied refrigerant: R407C. Units are controlled with the help of “dry contacts.”Standard complete set comprises: isolation pads, phase-control switch, relay adjusting condensation pressure through altering the fans’ rotation speed, service Schrader valves, and shutoff valves at the output of condensing unit. Condensing units filled with inert gas are delivered in dried form.
* Average evaporation temperature 5°, environmental temperature 32°C.
TYPE
FV685 oil (1 liter)Destined for filling the refrigerating loop.
Polyvinyl Essence
69
RefRigeRating equipment
NEDnew engineering Discoveries
www.air-ned.com
Mono-Block Chillers of NBA Series and Modular Chillers of NBA X Series
nbA
X
StAn
DAR
D
SizE
Pow
er
of k
it’s
cool
ing*
Num
ber
of b
lock
s
in m
odul
ar ch
iller
Ove
rall
pow
er
cons
umpt
ion*
kW kW kW
2Х096 204 2 2х33,9
2Х107 228 2 2х39,2
2Х128 268 2 2х44,4
2Х145 294 2 2х52,25
2Х163 344 2 2х58,65
2Х190 376 2 2х64,55
3Х128 402 3 3х44,4
3Х145 441 3 3х52,25
3Х163 516 3 3х58,65
3Х190 564 3 3х64,55
4Х145 588 4 4х52,25
4Х163 688 4 4х58,65
4Х190 752 4 4х64,55
5Х163 860 5 5х58,65
5Х190 940 5 5х64,55
6Х190 1128 6 6х64,55
nbA
StA
nD
ARD
Siz
E
Refr
iger
atin
g ca
pacit
y*
Pow
er c
onsu
mpt
ion*
Capa
city
stag
es
Diam
eter
of h
ydra
ulic
loop
’s fi
ttin
gs
Thre
ad co
nnec
tion
acco
rdin
g to
GOS
T 62
11-8
1**
Leng
th
Wid
th
Heig
ht
Nois
e pr
essu
re le
vel**
*
Tran
spor
tatio
n m
ass(1
)
kW kW % DU R mm mm mm dB(A) kg
39 45 15,46
0-33-66-100
50 2
2200
1150 2005
64 728,4
48 52 18,16 50 2 64 742,65
54 59 20,06 50 2 64 747,9
64 70 24,30-25-50-75-100
50 2 71 797
72 80 26,1 65 2,5 71 905
79 90 29,1
0-33-50-67-84-100
65 2,5 71 1044,5
96 102 33,9 65 2,5
3100
71 1065,5
107 114 39,2 65 2,5 71981
128 134 44,4 0-25-50-75-100 80 3 71
145 147 52,25
0-33-50-67-84-100
80 3 76 1311
163 172 58,65 80 3 76 1345,5
190 188 64,55 80 3 76 1361,5
DescriptionMono-block chillers in 12 standard sizes and modular chillers, in 16 standard sizes. Outdoor design versions with axial fans with refrigerating capacity from 45 to 1,128 kW. Design type: cooling only. Refrigerant: R407C Freon. Range of environmental air operating temperatures from + 5 to + 44°C. Maximum possible content of glycol in refrigerant blend: up to 40% (for design versions with embedded pump).Design philosophySmooth governing of fans’ rotation speed. No need to install a storage tank due to multiple adjustment degrees. Possibility to select an operation mode by inlet or outlet heat-transfer agent’s temperature. Sustainable operation of refrigerating loop components in all operation modes. Uniformly elapsed operating time of compressors and pumps. Possibility to be connected with BMS flow-control system for buildings: Ethernet, BACnet/IP, LonWorks, RS 485 (Modbus).Optional Accessoriesu1 – control of one pump (installed outside of the chiller)u2 – control of two pumps (installed outside of the chiller,
rotation according to operating time)mb – RS485 (Modbus) card of serial interface
* Conditions: cooled water temperature from 12 to 7°C, environmental air temperature 35°C** Installed in chillers with embedded pumps, primary pressure in expansion tank 1.5 atm.*** Noise pressure level is measured in the free sound field at the distance of 1m of the unit (from the intake side) and 1.5 m of supporting surface according to DIN 45635.(1) Unit without pumps.
Pump stations are designed for pumping liquids (water, inhibited water solutions of ethylene glycol or propylene glycol with low viscosity, etc.) and may be used in the air conditioning systems and various technological processes. 24 possible configurations with available static pressure up to 400 kPa. Complete set comprises expansion tanks for different overall capacities: from 35 to 150 l.
NST Remote Pump Stations for NBA Modular Chillers’ Kits
possible design versions:1A – one embedded low-pressure pump1b – one embedded medium-pressure
pump1C – one embedded high-pressure pump2A – two embedded low-pressure pumps
(rotation according to operating time)2b – two embedded medium-pressure
pumps (rotation according to operating time)
2C – two embedded high-pressure pumps (rotation according to operating time)
70
EquipmEnt2
Chillers for Operation with NBE 039-190 Remote Condensers
* Conditions: cooled water temperature from 12 to 7°C, environmental air temperature 35°C** Installed in chillers with embedded pumps, primary pressure in expansion tank 1.5 atm.*** Noise pressure level is measured in the free sound field at the distance of 1m of the unit (from the intake side) and 1.5 m of supporting surface according to DIN 45635.(1) Unit without pumps.
StAnDARD SizE 039 048 054 064 072 079 096 107 128 145 163 190COOling
Refrigerating capacity* kW 45 52 59 70 80 90 102 114 134 147 172 188COmpRESSORS
Number pieces 3 3 3 4 4 6 6 6 4 6 6 6Power consumption* kW 14,2 16,8 18,8 21,7 23,5 26,5 31,3 36,6 41,8 47,9 54 60,2Maximum operating current А 31,2 36,9 40,8 49,2 54,4 62,4 73,8 81,6 94,4 105,6 115,6 141,6Maximum inrush current А 68,8 90,6 100,2 102,9 113,8 116,8 156,6 173,2 166,8 195,2 230,6 239,2Capacity stages % 0-33-66-100 0-25-50-75-100 0-33-50-67-84-100 0-25-50-75-100 0-33-50-67-84-100Power supply V/Hz/phase 400/50/3+N+PE
WAtER lOOpWater consumption l/sec 2,14 2,48 2,81 3,33 3,81 4,29 4,86 5,43 6,38 7 8,19 8,95Pressure loss in the heat exchanger kPa 29,26 33,71 29,86 42,19 38,87 30,84 34,85 30,62 40,19 38,89 41,05 44,01
Full thrust of 1A, 2A pump kPa 145 138 131 212 204 193 187 180 170 160 201 183Full thrust of 1B, 2B pump kPa 250 230 280 240 300 295 275 265 255 290 270 250Full thrust of 1C, 2C pump kPa 350 345 385 375 450 450 450 430 390 410 400 390Volume of expansion tank** l 8 8 8 12 12 12 12 12 12 18 18 18
COnnECtiOn OF FREOn lOOpGas line mm 18 22 22 2*22 2*22 2*28 2*28 2*28 2*28 2*35 2*35 2*35Liquid line mm 22 22 22 2*18 2*18 2*22 2*22 2*22 2*28 2*28 2*28 2*28
COnnECtiOn OF WAtER lOOpDiameter DU 50 50 50 50 65 65 65 65 80 80 80 80
Thread connection according to GOST 6211-81 R 2 2 2 2 2 1/2 2 1/2 2 1/2 2 1/2 3 3 3 3
ACOuStiC CHARACtERiStiCSNoise pressure level*** dB(A) 58 58 58 60 60 60 60 60 63 63 63 63
StAnDARD SizE AnD mASSLength mm 1800 1800 1800 1800 1800 2400 2400 2400 2400 2400 2400 2400Height mm 1750Width mm 770Transportation mass(1) kg 560 570 575 630 635 715 760 780 780 905 935 955
DescriptionDesign version: cooling only. Refrigerant: R407C Freon. 12 standard sizes with refrigerating capacity from 45 to 188 kW. Maximum possible content of glycol in refrigerant blend – up to 40%.Design philosophyNo need to install a storage tank due to multiple adjustment degrees. Possibility to select an operation mode by inlet or outlet heat-transfer agent’s temperature. Sustainable operation of refrigerating loop components in all operation modes. Uniform operating time of compressors and pumps. Possibility to be connected with BMS flow-control system for buildings: Ethernet, BACnet/IP, LonWorks, RS 485 (Modbus).possible design versions:1A – one embedded low-pressure pump1b – one embedded medium-pressure pump1C – one embedded high-pressure pump2A – two embedded low-pressure pumps (rotation according to operating time)2b – two embedded medium-pressure pumps (rotation according to operating time)2C – two embedded high-pressure pumps (rotation according to operating time)Optional Accessoriesu1 – control of one pump (installed outside of the chiller)u2 – control of two pumps (installed outside of the chiller,
rotation according to operating time)mb – RS485 (Modbus) card of serial interfacelW – card of serial interface within LonWorks platform
71
RefRigeRating equipment
NEDnew engineering Discoveries
www.air-ned.com
nbE StAnDARD SizE 039 048 054 064 072 079 096 107 128 145 163 190
nnC StAnDARD SizE 039 048 054 064х2* 072х2* 079х2* 096х2* 107х2* 128х2* 145х2* 163х2* 190х2*
Heat exchanger’s inner volume l 23,8 27,1 27,1 17,9 23,4 23,8 27,1 27,1 36,5 48,3 48,3 48,3
FAnS
Number pieces 2 3 3 2 2 2 3 3 3 3 2 2
Fan’s diameter mm 630 630 630 630 630 630 630 630 630 630 710 710
Feeding V/Hz/phase 230 / 50 / 1+N+PE 380 / 50 / 3+N+PE
Power consumption kW 1,26 1,89 1,89 1,26 1,26 1,26 1,89 1,89 1,89 1,89 2,6 2,6
Maximum operating current А 5,8 8,7 8,7 5,8 5,8 5,8 8,7 8,7 8,7 8,7 5 5
COnnECting FlAngES OF FREOn lOOp
Injection linemm 18 22 22 2х 22 2х 22 2х 28 2х 28 2х 28 2х 28 2х 35 2х 35 2х 35
inch 3/4 7/8 7/8 2х 7/8 2х 7/8 2 х1 1/8 2 х1 1/8 2 х1 1/8 2 х1 1/8 2х 1 3/8 2х 1 3/8 2х 1 3/8
Intake linemm 22 22 22 2х 18 2х 18 2х 22 2х 22 2х 22 2х 28 2х 28 2х 28 2х 28
inch 7/8 7/8 7/8 2х 3/4 2х 3/4 2х 7/8 2х 7/8 2х 7/8 2 х1 1/8 2 х1 1/8 2 х1 1/8 2 х1 1/8
ACOuStiC CHARACtERiStiCS
Noise pressure level** dB(A) 64 64 64 64 64 64 64 64 64 64 71 71
SizES
Length (A) mm 2680 3880 3880 2680 2680 2680 3880 3880 2600 2600 2600 2600
Width (B) mm 700 700 700 700 700 700 700 700 1200 1200 1200 1200
Height (C) mm 1030 1030 1030 1030 1030 1030 1030 1030 1110 1110 1110 1110
mASS
Transportation mass kg 220 310 310 220 210 210 310 310 360 360 360 360
NNC Remote Condensers for Joint Operation with NBE 039-190 Chillers
Design version: Cooling only.Condenser type: With air horizontal discharge (flat) and air vertical discharge (V-shaped).Refrigerant: R407C Freon.
* important! set of 64x2…190x2 remote condensers consists of two similar condensers. The table indicates data with respect to one condenser only.** Noise pressure level is measured in the free sound field at the distance of 1m of the unit and 1.5 m of supporting surface according to DIN 45635.
Description12 models have been specially elaborated for joint operation with NBE chillers. NNC 039…054 remote condenser is required for NBE 039…054 chillers. Kit of NNC 064x2…190x2 remote condensers consisting of two similar condensers is required for NBE 064…190 chillers. Outdoor installation. Range of environmental air operating temperatures from -25°C to + 45°C.Design philosophySmooth adjustment of fans’ rotation speed. Cost-effective and efficient operation in different environmental conditions. Optimum solution with respect to noise level / capacity ratio. Low noise level during operation and reduced power consumption. Possibility to be mounted on wall (039-107 models) or horizontal surface. High durability of the structure and resistance to vibrations.
72
EquipmEnt2
mODEl nDlC1200 ES nDlC1300 ES nDlC1400 ES nDlC1500 ES nDlC1600 ES
Refrigerating capacity kW 4220 4572 4922 5276 5627
EER 7,04 6,98 7,03 6,99 7,04
Power consumption kW 594 649 695 749 793
Power supply 10000 V – 3 phase – 50 Hz
Transportation mass kg 18790 19220 19710 20170 20450
Length m 5490 5490 5490 5490 5490
Width m 2800 2800 2800 2800 2800
Height m 2920 2920 2920 2920 2920
mODEl nDlC1700 ES nDlC1800 ES nDlC1900 ES nDlC2000 ES nDlC2100 ES nDlC2200 ES
Refrigerating capacity kW 5979 6330 6682 7034 7386 7737
EER 7,04 7,02 7,06 7 7,04 7,03
Power consumption kW 843 895 940 996 1040 1093
Power supply 10000 V – 3 phase – 50 Hz
Transportation mass kg 23370 23620 23850 24130 24130 24130
Length m 5790 5790 5790 5790 5790 5790
Width m 3150 3150 3150 3150 3150 3150
Height m 3180 3180 3180 3180 3180 3180
NDLC Chillers with Centrifugal Compressors
nDlC-m and nDlC-H are single-stage. Refrigerating capacity of 1,500 ÷ 3,800 kW.nDlC-ES are two-stage. Refrigerating capacity of 4200 ÷ 7,700 kW.nDlC-VSD are two-stage with VSD frequency inverter. Refrigerating capacity of 1,500 ÷ 4,200 kW.Applied refrigerant: R 134a.
NDLC chillers with centrifugal compressors are water cooling machines for OViK systems with high EER7 and IPLV11.6 power-efficiency coefficients, which are able to operate in “Free Cooling” mode. Chillers’ capacity may be smoothly adjusted within the range from 10% to 100% of rated refrigerating capacity. It is possible to use high voltage motor from 400 to 10,000 V.
73
RefRigeRating equipment
NEDnew engineering Discoveries
www.air-ned.com
Chillers with Water Cooling of TURBOLINE Condenser with Compressors
gWH 351-3811: chillers with water cooling of TURBOLINE, TT/Y condenser with TURBOCOR compressors with refrigerating capacity 333 ÷ 3,696 kW.gWH 291-1581: chillers with water cooling of TURBOLINE, TT/Y condenser with TURBOCOR compressors with refrigerating capacity 280 ÷ 1,546 kW.Applied refrigerant: R134a.
TURBOLINE chillers with TURBOCOR compressors are designed for the operation as a part of highly efficient cooling systems involving central air conditioning systems.Design versions:gWH – cooling only, for operation with open water cooling tower.gWH/DR – cooling only, for operation with dry cooler.
GWH…TT/Y MODELS 351 411 541 701 871 1031 1201 1311 1391
Refrigerating capacity kW 333 396 523 682 840 999 1166 1265 1344
Power consumption kW 62 72 94 123 148 177 214 216 231
EER 5,37 5,5 5,56 5,54 5,68 5,64 5,45 5,86 5,82
Compressors n° 1 1 1 2 2 2 2 2 3
Loops n° 1 1 1 1 1 1 1 1 1
Length mm 3220 3220 3180 3260 3340 3340 3360 3360 4300
Width mm 2170 2170 2170 2400 2400 2400 2450 2450 2450
Height mm 980 980 1000 1120 1160 1160 1260 1260 1250
Mass kg 2690 2700 2720 3200 3500 3510 4020 4130 5260
GWH…TT/Y MODELS 1591 1851 2111 2431 2771 3121 3471 3811
Refrigerating capacity kW 1546 1792 2050 2352 2688 3024 3360 3696
Power consumption kW 268 316 355 429 470 539 596 647
EER 5,77 5,67 5,77 5,48 5,72 5,61 5,64 5,71
Compressors n° 3 3 4 4 5 5 6 6
Loops n° 1 1 1 1 1 1 1 1
Length mm 4400 4400 4370 4500 5620 5750 6040 6040
Width mm 2520 2520 2520 2660 2820 2800 3000 3000
Height mm 1420 1420 1470 1630 1510 1630 1800 1800
Mass kg 5820 5940 6250 8020 8170 10290 11900 11940
GWH/DR…TT/Y MODELS 291 341 461 611 781 971 1171 1371 1581
Refrigerating capacity kW 280 336 448 594 762 952 1142 1344 1546
Power consumption kW 66 83 107 142 173 230 260 311 350
EER 4,21 4,07 4,18 4,19 4,39 4,14 4,39 4,32 4,41
Compressors n° 1 1 2 2 2 3 3 4 4
Loops n° 1 1 1 1 1 1 1 1 1
Length mm 3220 3220 3200 3220 3340 4260 4270 4270 4370
Width mm 2170 2170 2170 2170 2400 2400 2450 2450 2520
Height mm 980 980 1000 1000 1150 1160 1250 1410 1470
Mass kg 2690 2690 2910 2920 3470 4600 5210 5480 6130
74
EquipmEnt2
Chillers and Heat Pumps with Air Cooling of Condenser, Outdoor Version
Chillers with Air Cooling of Condenser, Indoor Version
Indoor Mounted Chillers with Remote Condensers
* Heating mode
nWA/Cl/Wp* 4 – 20 S/K/prefrigerating capacity 4.2 – 20.5 kW; nWA/Cl/Wp* 24 – 40 S/K/p
refrigerating capacity 24.8 – 178 kW.
NWA/CL/WP* 4 – 20 S/K/P chillers are manufactured in 10 standard sizes and NWA/CL/WP* 24 – 40 S/K/P chillers, in 14 standard sizes, with axial fans and scroll compressors.
nWR 4 – 34 S/K/p refrigerating capacity 4.2 – 33.4 kW; nWR 051 – 172 S/K/p
refrigerating capacity 47.6 – 178 kW.
NWR chillers are manufactured in 23 standard sizes with high-pressure fans and scroll compressors.
nEE 4 – 40 S/K/p refrigerating capacity 4 – 41.5 kW; nEE 051– 172 S/K/p
refrigerating capacity 50.8 – 176 kW; gEE 322 – 2582 V V / Y
refrigerating capacity 235– 2,168 kW.
NEE chillers are manufactured in 24 standard sizes with scroll compressors and operate on R407C Freon.GEE chillers are manufactured in 18 standard sizes with screw compressors and operate on R134A Freon.
75
RefRigeRating equipment
NEDnew engineering Discoveries
www.air-ned.com
Precision Conditioners
Precision conditioners are designed for accurate maintenance of air parameters in important premises equipped with servers, informational centers, and hardware implementing highly efficient technologies. There are design versions with air cooling of condensate and with heat exchanger cooled by water.
DE – with direct air cooling, WC – with direct water cooling, CW – heat exchanger with cooling water.
Standard size (S – small, M – middle, L – large) Exhaust side (T – exhausts upwards, B – exhaust downwards) 0 – cooling from chiller, 1 – one compressor, 2 – two compressors Standard size of conditioner C – cooling only
E – cooling and heating U – cooling and moistening D – cooling, heating, moistening, drying
DE 049m t 2 C
Chillers with Water Cooling of Condenser
nWH 4 – 40 S/K/prefrigerating capacity 4.6 – 49.2 kW; nWH 051 – 172 S/K/p
refrigerating capacity 55.4 – 195 kW; gWH 182 – 1602 V V / z
refrigerating capacity 185 – 1,602 kW.
NWH chillers are manufactured in 24 standard sizes with scroll compressors and operate on R410C Freon.GWH 182 – 1602 V V / Z chillers are manufactured in 20 standard sizes with screw compressors and operate on R407C Freon.
76
EquipmEnt2
RM Remote Water Duties
NRC Remote Condensers
GRC Dry Coolers (Dry Cooling Towers)
Remote water duties for indoor and outdoor installation. Plants of two standard sizes with storage tank’s capacity of 1,500 and 2,500 l. Each standard size allows the complete set with one-pump or two-pumps group. Five models of pump stations with rated power consumption from 3 kW to 22 kW.
Remote condensers with air cooling for outdoor installation. Designed for connecting with NEE and GEE condenser-free chillers.
Dry coolers with axial fans for outdoor installation. Designed for connecting with NWH and GWH chillers with water cooling of condenser.
77
RefRigeRating equipment
NEDnew engineering Discoveries
www.air-ned.com
Fan Coils with Centrifugal Fans and Inverter EC-Motor
Channel Fan Coils
ND Cartridge Fan Coils
NHW/EC Wall Mounted Fan Coils with Inverter EC-Motor
Represented in 14 standard sizes with overall refrigerating capacity from 1.31 kW to 7.26 kW. High quality operation parameters and utmost noiselessness. Minimum power consumption by models with inverter EC-motors. Vast variety of models and broad choice of accessories.
Available at warehouse.Produced in Italy.
Middle-pressure (up to 100 Pa) channel fan coils of L series are represented in 5 standard sizes and 2 modifications with overall refrigerating capacity from 3.77 kW to 17.79 kW. High-pressure (up to 120 Pa) channel fan coils of R series are represented in 6 standard sizes with overall refrigerating capacity from 5.86 kW to 39.13 kW. Two-pipe or four-pipe design versions.
Produced in Italy.
Represented in 9 standard sizes with overall refrigerating capacity from 1.8 kW to 12.6 kW. High quality operation parameters and utmost noiselessness. Vast variety of models and broad choice of accessories.
Available at warehouse.
Represented in 6 standard sizes with overall refrigerating capacity from 2.1 kW to 5.4 kW. Minimum power consumption and low noise level due to the application of inverter EC-motors. Infrared remote control unit is included in the standard complete set. Produced in Italy.
Portfolio
3
80
3 Portfolio
DHL WareHouse Pushkino
Delivered equipment: aIrNeD central air conditioners, channel ventilation equipment
Facility’s area: 300,000 m2
ProDuctIoN ceNterMoscow
Delivered equipment: aIrNeD central air conditioners, channel ventilation equipment
Facility’s area: 9,000 m2
NEDNew Engineering Discoveries
www.air-ned.com 81
IndustrIal BuIldIngs.Warehouse PremIses
recoNstructIoN of Ps-350 substatIoN, Heat-aND-PoWer PLaNt 5 “Nevsky” saint Petersburg
Delivered equipment: LIteNeD central air conditioners Facility’s area: 5,000 m2
“coNtINeNtaL” tIre ProDucINg PLaNtkaluga
Delivered equipment: chillersFacility’s area: 85,000 m2
82
3 Portfolio
“Iceberg” traDe ceNter city of stary oskol
Delivered equipment: chillers, fan coils, steam humidifier Facility’s area: 10,000 m2
“festIvaL” traDe ceNter city of angarsk
Delivered equipment: LIteNeD and aIrNeD central air conditioners, channel ventilation equipment, fire-fighting valves
Facility’s area: 22,000 m2
NEDNew Engineering Discoveries
www.air-ned.com 83
NEDNew Engineering Discoveries
www.air-ned.com
Trade and amusemenT CenTers
“aLexaNDrIa” traDe aND busINess ceNter sochi
Delivered equipment: channel ventilation equipment, chillers, fan coils
Facility’s area: 40,000 m2
“oraNzHereya” traDe ceNter city of bataysk
Delivered equipment: aIrNeD central air conditioners, channel ventilation equipment
Facility’s area: 10,500 m2
84
3 Portfolio
“goroD – Leroy-MerLIN” traDe ceNterMoscow
Delivered equipment: LIteNeD and aIrNeD central air conditioners, channel ventilation equipment
Facility’s area: 35,000 m2
“reD square” traDe ceNtercity of armavir
Delivered equipment: channel ventilation equipment, chillers
Facility’s area: 40,000 m2
NEDNew Engineering Discoveries
www.air-ned.com 85
NEDNew Engineering Discoveries
www.air-ned.com
Trade and amusemenT CenTers
“a2LogIstIc” LogIstIc ceNterkrasnodar
Delivered equipment: aIrNeD central air conditioners, channel ventilation equipment Facility’s area: 40,000 m2
“karnaval” trade centerkrasnodar
Delivered equipment: channel ventilation equipment, chiller Facility’s area: 17,000 m2
86
3 Portfolio
“IyuN” traDe aND aMuseMeNt ceNtercity of Mytishchi
Delivered equipment: LIteNeD and aIrNeD central air conditioners, channel ventilation equipment
Facility’s area: 25,000 m2
“MarMaLaDe” traDe ceNtercity of taganrog
Delivered equipment: LIteNeD and aIrNeD central air conditioners, channel ventilation equipment
Facility’s area: 52,000 m2
NEDNew Engineering Discoveries
www.air-ned.com 87
NEDNew Engineering Discoveries
www.air-ned.com
Trade and amusemenT CenTers
traDe aND aMuseMeNt ceNters “MIr reMoNta HDM-yug”rostov-on-Don
Delivered equipment: LIteNeD central air conditioners, channel ventilation equipmentFacility’s area: 24,000 m2
“uNIMaLL” traDe ceNterMoscow region
Delivered equipment: aIrNeD central air conditioners, channel ventilation equipment
Facility’s area: 300,000 m2
88
3 Portfolio
N. I. PIrogov cIty cLINIcaL HosPItaL # 1Moscow
Delivered equipment: aIrNeD central air conditioners, channel ventilation equipment Facility’s area: 4,000 m2
NEDNew Engineering Discoveries
www.air-ned.com 89
Medical Buildings
I. M. secHeNov MoscoW MeDIcaL acaDeMy, PHtHIsIoPuLMoNoLogy researcH INstItuteMoscow
Delivered equipment: LIteNeD and aIrNeD central air conditioners, channel ventilation equipment
Facility’s area: 24,000 m2
kgbuz kray cLINIcaL HosPItaL city of barnaul
Delivered equipment: LIteNeD and aIrNeD central air conditioners, humidifier, control and measuring equip-ment and automatics, channel ventilation equipment, chiller
Facility’s area: 14,000 m2
90
3 Portfolio
MeDsI cHILDreN’s PoLycLINIc Moscow
Delivered equipment: LIteNeD and aIrNeD central air conditioners, channel ventilation equipment Facility’s area: 5,000 m2
NEDNew Engineering Discoveries
www.air-ned.com 91
Medical Buildings
tusHINo cHILDreN’s cLINIcaL HosPItaL Moscow
Delivered equipment: aIrNeD central air conditioners, channel ventilation equipment
Facility’s area: 35,000 m2
M. f. vLaDIMIrsky MoNIkI state INstItutIoNMoscow
Delivered equipment: LIteNeD and aIrNeD central air conditioners
Facility’s area: 5,500 m2
92
3 Portfolio
“aDMIraL” HoteLcity of saransk
Delivered equipment: LIteNeD central air conditioners, chiller Facility’s area: 1,500 m2
“vertoL-exPo” exHIbItIoN ceNter rostov-on-Don
Delivered equipment: LIteNeD and aIrNeD central air conditioners, chiller Facility’s area: 35,000 m2
NEDNew Engineering Discoveries
www.air-ned.com 93
Residential CenteRs. Hotels
korstoN” traDe, aMuseMeNt, aND HoteL ceNter kazan
Delivered equipment: aIrNeD central air conditioners, smoke removal fans, fire-fighting valves
Facility’s area: 70,000 m2
“Da vINcI” resIDeNtIaL ceNter Moscow
Delivered equipment: aIrNeD central air conditioners, smoke removal fans
Facility’s area: 90,000 m2
94
3 Portfolio
koreaN busINess ceNter Moscow
Delivered equipment: aIrNeD central air conditioners, fire-fighting valves, smoke removal systems Facility’s area: 50,000 m2
NEDNew Engineering Discoveries
www.air-ned.com 95
Office centers. AdministrAtive Buildings
INfINItI auto saLes ceNter kazan
Delivered equipment: LIteNeD and aIrNeD central air conditioners, channel ventilation equipment
Facility’s area: 1,600 m2
HoNDa DeaLer’s ceNter city of aksay
Delivered equipment: channel ventilation equipment, control and measuring equipment and automatics
Facility’s area: 2,500 m2
96
3 Portfolio
“scHooL # 35” eDucatIoNaL INstItutIoN kazan
Delivered equipment: aIrNeD central air conditioners, channel ventilation equipment, fire-fighting valves
Facility’s area: 2,500 m2
kINDergarteN Moscow
Delivered equipment: ventilation equipment, smoke removal systems, air conditioning equipment
Facility’s area: 2,500 m2
NEDNew Engineering Discoveries
www.air-ned.com 97
Office centers. AdministrAtive Buildings
cIty court buILDINg saint Petersburg
Delivered equipment: fan coils Facility’s area: 5,000 m2
acaDeMy of tHe feDeraL securIty servIce (fsb) Moscow
Delivered equipment: ventilation system equipment Facility’s area: 100,000 m2
98
3 Portfolio
“NatIoNaL staNDarD” baNkMoscow
Delivered equipment: LIteNeD and aIrNeD central air conditioners, channel ventilation equipment, system involving process control in buildings, chiller, fan coils, fire-fighting valves Facility’s area: 60,000 m2
NEDNew Engineering Discoveries
www.air-ned.com 99
Office centers. AdministrAtive Buildings
“vostok” toyota ceNter city of aksay
Delivered equipment: LIteNeD and aIrNeD central air conditioners
Facility’s area: 5,000 m2
“rus-traDe” kIa MuLtIfuNctIoNaL ceNter city of Podolsk
Delivered equipment: LIteNeD and aIrNeD central air conditioners, channel ventilation equipment, condensing units
Facility’s area: 2,500 m2
100
3 Portfolio
“sPortLIfe” sPorts cLubsaint Petersburg
Delivered equipment: LIteNeD and aIrNeD central air conditioners, channel ventilation equipment Facility’s area: 5,050 m2
NEDNew Engineering Discoveries
www.air-ned.com 101
Sport CenterS
“LocoMotIve” ceNtraL staDIuM Moscow
Delivered equipment: system involving process control in buildings Facility’s area: 12,000 m2
staDIuM of “sPartak” footbaLL cLub Moscow
Delivered equipment: LIteNeD central air conditioners Facility’s area: 10,000 m2
102
3 Portfolio
“H20” aqua Parkrostov-on-Don
Delivered equipment: channel ventilation equipment, condensing units Facility’s area: 24,000 m2
NEDNew Engineering Discoveries
www.air-ned.com 103
Sport CenterS
“coLIseuM” sPorts ceNter city of grozny
Delivered equipment: LIteNeD and aIrNeD central air conditioners, modular chillers, fan coils
Facility’s area: 8,000 m2
“IzHorets” Water sPorts ceNter saint Petersburg
Delivered equipment: aIrNeD central air conditioners, condensing units
Facility’s area: 5,000 m2
104
3 Portfolio
a. N. raDIsHcHev saratov art MuseuM saratov
Delivered equipment: LIteNeD central air conditioners, channel ventilation equipment, systems involving process control in buildings Facility’s area: 1,700 m2
a. scHNIttke saratov regIoNaL PHILHarMoNIc socIety saratov
Delivered equipment: LIteNeD and aIrNeD central air conditioners, channel ventilation equipment, smoke removal systems Facility’s area: 5,000 m2
NEDNew Engineering Discoveries
www.air-ned.com 105
Special FacilitieS
DHL WareHouse city of Pushkino
Delivered equipment: aIrNeD central air conditioners, channel ventilation equipment
Facility’s area: 300,000 m2
MuseuM of kazakHstaN’s fIrst PresIDeNt city of astana
Delivered equipment: aIrNeD central air conditioners, channel ventilation equipment, chiller
Facility’s area: 5,000 m2
sAlEs GEoGrAphy
4
SaleS GeoGraphy
108
4
YEREVAN
MINSK
MOSCOW
SAINT PETERSBURG
ROSTOV-ON-DON
KALININGRAD
VORONEZH
KRASNODARTOMSK
NOVOSIBIRSK
KRASNOYARSK
KHABAROVSKYEKATERINBURG
NABEREZHNYE CHELNY TYUMEN
CHELYABINSKUFA
KAZAN
SAMARA
NIZHNY NOVGOROD
ASTANA
YUZHNO-SAKHALINSK
TASHKENT
VOLGOGRAD
cITIES WHERE OuR EquIPMENT OPERaTES
NED climate systems are installed at dozens of thousands urban and industrial facilities all over Russia.
company’s geography
NED equipment has been designed and manufactured taking into account the climate peculiarities of our country. It is able to operate at utmost low temperatures and drastic seasonal weather fluctuations.
Dependability of our equipment has been proved by its multiyear operation in real conditions.
109
NEDNew Engineering Discoveries
www.air-ned.com
YEREVAN
MINSK
MOSCOW
SAINT PETERSBURG
ROSTOV-ON-DON
KALININGRAD
VORONEZH
KRASNODARTOMSK
NOVOSIBIRSK
KRASNOYARSK
KHABAROVSKYEKATERINBURG
NABEREZHNYE CHELNY TYUMEN
CHELYABINSKUFA
KAZAN
SAMARA
NIZHNY NOVGOROD
ASTANA
YUZHNO-SAKHALINSK
TASHKENT
VOLGOGRAD
WaRehouse
CoNvENtioN:
office
seRVice centeR
rEprEsENtAtioNs:
Volgograd
Voronezh
Yekaterinburg
kazan
kaliningrad
krasnodar
krasnoyarsk
nizhny novgorod
novosibirsk
Rostov-on-don
samara
saint petersburg
tomsk
tyumen
ufa
khabarovsk
Yuzhno-sakhalinsk
Yerevan, armenia
astana, kazakhstan
tashkent, uzbekistan
Distributors:
naberezhnye chelny
chelyabinsk
moscow
minsk, belarus
CoNtACts
5
112
5 ContaCts
contacts
Central office:address: 11/28 shchipok st., moscow 115054tel.: 8(800) 555 8448 (multichannel)e-mail: [email protected]
OffIcES IN MOScOW
REPRESENTaTIONS
Warehouse:address: 1 energetikov st., city of dzerzhinsky, moscow Region
Volgogradtel.: 8 (8442) 26-04-28/2910 Grushevskaya St., Volgograd 400074Email: [email protected]
Voronezhtel.: 8 (473) 220-50-0930 Volgogradskaya St., 1st floor, Voronezh 394028Email: [email protected]
Yekaterinburgtel.: 8 (343) 270-22-123 Generalskaya St., office 401, Yekaterinburg 620062Email: [email protected]
kazantel.: 8 (843) 524-70-5358 Ibragimova Av., office 506, Kazan, Republic of Tatarstan 420066 (“Na Ibragimova” Business Center)Email: [email protected]
kaliningradtel.: 8 (962) 254-22-92
8 (921) 260-87-584 Pobedy Sq. office 3, 3rd floor, Kaliningrad 236000
krasnodartel.: 8 (861) 211-20-92
8 (861) 211-20-36/373/5 Vishnyakovoy St., office 5, Krasnodar 350001Email: [email protected]
krasnoyarsktel.: 8 (391) 216-03-6065 Shakhtyorov St., office 15, 3rd floor, Krasnoyarsk 660020Email: [email protected]
nizhny novgorodtel.: 8 (831) 411-15-58
8 (831) 411-15-5931A Premudrova St., Nizhny Novgorod 603034Email: [email protected]
novosibirsktel.: 8 (383) 319-12-1326 Krylova St., office 515, Novosibirsk 630091Email: [email protected]
Rostov-on-dontel.: 8 (863) 203-72-70
8 (863) 203-72-711/52 Pyatidesyatiletiya Rostselmasha St., office 413, Rostov-on-Don 344065Email: [email protected]
samaratel.: 8 (846) 207-18-08
8 (846) 207-18-98 8 (846) 207-19-98
95 Sanfirovoy St., letter 4, office 308, Samara 443080Email: [email protected]
113
NEDNew Engineering Discoveries
www.air-ned.com
Offices in MoscowRepresentationsDistributors
moscow“transenergomash” llc5 Cheryomushkinsky passage, Moscow 117036www.transenergomash.biz
“expert-oborudovaniye” llc24A Bolshaya Cherkizovskaya St., Bldg. 1, Moscow 107553www.expert-oborudovanie.org
naberezhnye chelny“kamVent plus” llctel.: 7 (8552) 53-51-83
7 (8552) 53-52-2287 Remontny passage, Naberezhnye Chelny, Republic of Tatarstan 423800, p/o box 32009
chelyabinsk“investitsii i stroitelstvo” llctel.: 7 (351) 778 52 43/449 Sverdlovsky Trakt, ChelyabinskEmail: [email protected]
belarus, minsk“teplomasterplyus” llctel.: 8 (017) 215-01-04
8 (017) 215-01-0527 Lenina St., room 160, Minsk 220030 (“Leningrad” Center)http://teplomaster.by
DISTRIBuTORS
saint petersburgtel.: 8 (812) 655-52-208 Melnichnaya St., office 508, Saint Petersburg 192019Email: [email protected]
tomsktel.: 8 (923) 406-33-17Tomsk 634003Email: [email protected]
tyumentel.: 8 (3452) 30-70-84
8 (3452) 62-53-04100 Moskovsky Trakt St., office 402, Tyumen 625049Email: [email protected]
ufatel.: + 7 (347) 246-98-46134/4 Mendeleyeva St., office 6, Ufa 450022Email: [email protected]
khabarovsktel.: 8 (4212) 75-19-00132 Kalinina St., office 502, Khabarovsk 680028Email: [email protected]
Yuzhno-sakhalinsktel.: 8 (4242) 22-99-95 (res.)284 Mira Av., Apt. 7, Yuzhno-Sakhalinsk 693006Email: [email protected]
armenia, Yerevan“Waelcon” firmtel.: 374 10 5813991/3 Byuzand St., 6th floor, Yerevan, Armenia 0010Email: [email protected]://waelcon.am
uzbekistan, tashkenttel.: 8 (10998) 90-174-48-221 Katta Chilanzar St., 2nd passage, Tashkent, Uzbekistan 100115Email: [email protected]
astana, kazakhstan“letex” llctel.: 8 (7172) 37-04-32
+7700330269521A Brusilovskogo St., Astana, KazakhstanEmail: [email protected]
“Vent center” llctel.: 8 (7172) 46 74 75
8 (7172) 76 83 827 Turan Av., Astana, Kazakhstan 010000
114
115
116
© NED. All rights reserved. The directory has a trial character, not an offer. The company reserves the right to change specifications listed in the catalog.
www.ned-russia.su+7 (495) 204-30-01, 8(800) 775-42-13
E-mail: [email protected]