clifford & snell hazardous area explosion proof sounders & beacons

30
Clifford & Snell Tom Cribb Road Thamesmead London UK SE28 0BH Tel: +44 (0) 208 317 1717 or +44 (0) 208 316 4477 Fax: +44 (0) 208 317 2400 Email: [email protected] Web: www.cliffordandsnell.com Audible & Visual Signals

Upload: thorne-derrick-international

Post on 12-Apr-2017

2.151 views

Category:

Technology


5 download

TRANSCRIPT

Page 1: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Clifford & Snell

Tom Cribb Road Thamesmead London UK SE28 0BH Tel: +44 (0) 208 317 1717 or +44 (0) 208 316 4477 Fax: +44 (0) 208 317 2400 Email: [email protected] Web: www.cliffordandsnell.com

Audible & Visual Signals

michael ryan
MR STAMP 2
Page 2: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Clifford & Snell was originally established in 1929 and has a History of pioneering many elec-tronic systems and devices. In 1967 the company was responsible for the introduction of the world's first ever electronic sounder. This breakthrough in technology became the foundation for a long and established role in the manufacture and development of future generations of product.

The Company offers a comprehensive range, addressing a wide variety of applications and industry sectors, including Hazardous Area, Industrial and Process Control, through to the Fire and Security market. The nature of our industry demands quality and reliability at all times and this is achieved by employing the very latest assembly and manufacturing techniques, within our UK manufacturing facility.

Our customers require continuous quality of the highest standard and this is achieved through our BS EN ISO 9001: 2000 Quality Management System, which ensures total control throughout the entire manufacturing process. Clifford & Snell are committed to maintaining its product approvals to address the industries needs on a worldwide basis and certification includes UL, cULus, ATEX, GOST-R, IECEx, EN54-3, VdS and GL.

Areas such as Oil & Gas where Standards & Certification are an essential part of the design criteria. The Yodalex range of Explosion Proof Sounders, Strobes and Call Point Stations meet the necessary industry standards and directives with compliance to the North American UL, cULus, IECEx, European ATEX, and for the Russian market, GOST-R, which allows compliance on a truly global basis.

Industrial & Process Control

Hazardous Area

Industrial & Process Control is an important market and early indication of a process breakdown, malfunction or overheating is vital in relation to safety both from the perspective of safeguarding employees as well as preventing costly equipment damage and subsequent downtime and loss of productivity. The Yodalarm sounders and Yodalight sounder/strobes provide an audible and visual alarm function, with UL, cULus, GL,Vds and the EN54-3 approval, allowing compatibility with a wide variety of applications and industries.

Fire & General Signalling For Fire and General Signalling applications the Yodac range provides an ideal solution. With sound outputs up to 106dB, 32 international sound tones, AC or DC supply voltages, a range of lens and strobe options and approvals such as EN54-3, VdS, UL and cULus, this product offers an ideal signalling solution across most industry sectors.

For more information visit our web site www.cliffordandsnell.com

Company Profile

michael ryan
MR STAMP 2
Page 3: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com C l i f f o r d & S n e l l INDEX

DESCRIPTION TYPE NO.

PAGE NO.

APPROVALS

HAZARDOUS AREA

Yodalex Sounder UL / ATEX / GOST / IECEx 110 YO6 19 1 Yodalex Sounder/Strobe UL / ATEX / GOST / IECEx 110 YL6 19 1

Intrinsically Safe Sounders ATEX 105/110 YO3/YO4/YO5 21 4

Intrinsically Safe Flashing Beacons ATEX V4IS 21 5

Sounder UL / EN54-3 116/120 YO8/YO8S 21 7

Yodalex Strobe UL / ATEX / GOST / IECEx V6 19 1

INDUSTRIAL / FIRE SOUNDERS & STROBES (YODALARM - YODALIGHT)

Sounder / Strobe UL / EN54-3 116/120 YL8/YL8S 21 7

Sounder UL / EN54-3 / VdS / GL 110 YO5 21 8

Sounder / Strobe UL / EN54-3 / Vds 110 YL5 21 8

Sounder Multi-Stage EN54-3 106/116 YO4 /YO5/YO8 22 11 Sounder UL / EN54-3 / VdS 100 YO3 21 10

Xenon Strobe UL / VdS V4 Xenon 22 12 LED Flashing & Status Beacons V4 LED 22 13

GENERAL PURPOSE SOUNDERS Carillon Sounder EN54-3 104 CN 22 14

Face Plate Sounder (Quad) EN54-3 96 FP 23 15

Sounder/Strobe EN54-3 100 YL2 23 16

LC Sounder 100 LC 23 17

Door Holder DH 23 18

MISCELLANEOUS

Mains Adaptor MA 23 18

Circuit Security Keyswitch KS 23 18

CLASSIFICATION REFERENCE TABLES 26

dB

Intrinsically Safe Status Beacons ATEX V4IS 21 6

Sounder / Strobe UL / EN54-3 / Vds 106 YL4 21 9

Sounder UL / EN54-3 / VdS 106 YO4 21 9

WIRING DIAGRAMS

TONE TABLE 24

(See Wiring Diagrams column for Unit association) WIRING DIAGRAMS 19

to 23

TONE TABLE (FOR USE WITH MULTI-STAGE SOUNDER MODELS YO4 - YO5 - YO8 ONLY) 25

Yodalex Directional Sounder ATEX / GOST / IECEx 115 YO9 20 2 Yodalex Call Point Stations ATEX / GOST / IECEx MCP 20 3

Intrinsically Safe Sounders/Strobes ATEX 105/110 YL4/YL5 21 4

michael ryan
LOGO
Page 4: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

• Omni Directional high output sounder 110dB max @ 1 meter • 2 stage alarm, independently selectable 2nd stage • All units share a common explosion proof housing • Meets UL, CSA, GOST, ATEX and IECEx Approvals • ATEX / IECEx Approved for Gas & Dust • Zone 1 & 2, 21 & 22. • Dual cable entry, cable in - cable out: c/w ATEX certified plug and dustcover as standard on ATEX models; UL models supplied with 2 x 1/2 inch NPT adaptors. • Aluminium enclosure with stainless steel fasteners. • Lens guard provided as standard • Flash rate 1 per second. • Weather proof flame retardant ABS horn • 7 Lens colours in flame retardant polycarbonate, Clear (C), Opal (O), Yellow (Y), Red (R), Amber (A), Blue (B), Green (G). • Telephone Initiate option available - contact Sales Office • 32 selectable tones meeting international regulations • Sound selection via DIL switches. • Temperature class T4 Standard, Class T6 Optional

TECHNICAL SPECIFICATION

276 (10.9”) 288 (11.3”)

420 (16.5”)

145 (5.7”)

DIMENSIONS mm

ATEX

Controlled document No. D7385-01-06 (CN100301)\\ My Documents\ SALES DATA\ data sheets\Yodalex

V6 Y06 YL6

OPERATING TEMPERATURES STANDARD OPTIONAL European IIB T4 (-35º to +60ºC or T6 (-35º to +40ºC) European IIB+H2 T4 (-20º to +60ºC or T6 (-20º to +40ºC) For T6 Class refer to Sales Office

APPROVAL SPECIFICATION Underwriters Laboratories UL Standards UL 464, UL 1203, UL 1638 Control No.8N30 (Sounder YO6 and Combined Unit YL6) Control No.13JM (Strobe V6 only) UL Classifications Class I Division 1, Gas Group BCD Class II Division 1, Gas Group EFG (Strobe V6 only) CUL Canada CSA C22.2 No.25-M1966, CSA C22.2 No. 30-M1986 European Standards EN60079-0:2004 (EN50014:1997+Amendments 1 and 2) EN60079-1:2004 (EN50018:2000) EN50281-1-1:1998. ATEX Directive 94/9/EC Baseefa02ATEX0212X II2 GD Ex d IIB T4 (or T6 see above) Baseefa02ATEX0222X II2 GD Ex d IIB+H2T4 (or T6 see above) Russian Approval International Certification GOST-R IECEx

IIB only IIB+H2

75 (3”)

C l i f f o r d & S n e l l

Explosion Proof Sounders & Beacons

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

GOST-R

MAIN FEATURES

All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

Yodalex

Sounder YO6 Combined Sounder Strobe YL6

EU / RU / IN

UL

24Vdc 48Vdc 115Vac 230Vac

Supply Voltage

Certification

CONFIGURATOR

European USA/Canada Russian International

Unit Type

Lens Colour

Strobe V6

24Vdc 48Vdc 115Vac 230Vac

Sounders only YO6

5 Joule 20 Joule 10 Joule

Sounder/Strobe YL6 Strobe only V6

V6 Only V6 & YL6

or or

• IP66 NEMA 4X • Sounder/Strobe 24Vdc (YL6) (UL, ATEX, GOST, IECEx) 570mA

• Sounder 24Vdc (YO6) (UL, ATEX, GOST, IECEx) 350mA • Strobe 24Vdc (V6) 5 J (UL, ATEX, GOST, IECEx) 220mA • 24Vdc (V6) 10J ( ATEX, GOST, IECEx) 500mA • 24Vdc (V6) 20J ( ATEX, GOST, IECEx) 1.1A • 48Vdc (V6) 5J (UL, ATEX, GOST, IECEx) 135mA • 48Vdc (V6) 10J ( ATEX, GOST, IECEx) 300mA • 48Vdc (V6) 20J ( ATEX, GOST, IECEx) 560mA

• Sounder 115Vac (YO6) (UL, ATEX, GOST, IECEx) 110mA

• Strobe 115Vac (V6) 5 J (UL, ATEX, GOST, IECEx) 90mA

• 115Vac (V6) 10J ( ATEX, GOST, IECEx) 105mA

• 115Vac (V6) 20J ( ATEX, GOST, IECEx) 260mA

• Sounder/Strobe 115Vac (YL6) 5J (UL, ATEX, GOST, IECEx) 200mA

• Sounder 230Vac (YO6) (UL, ATEX, GOST, IECEx) 55mA

• Strobe 230Vac (V6) 5J (UL, ATEX, GOST, IECEx) 45mA

• 230Vac (V6) 10J ( ATEX, GOST, IECEx) 53mA

• 230Vac (V6) 20J ( ATEX, GOST, IECEx) 170mA

Mounting Bracket provided. 2 holes x M8 clearance

IIB+H2

Gas Group C,D

IIB

Gas group B

IECEx

Telephone Initiate

michael ryan
LOGO
Page 5: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717

Fax: +44 (0)20 8317 2400 Email: [email protected]

Web Site: www.cliffordandsnell.com

• High sound output 115dB at 1 metre • Light weight Glass Reinforced Polyester (GRP) Exd Enclosure - for use in potentially explosive areas • Low current consumption • ATEX / IECEx Approved Gas & Dust. Zones 1 & 2, 21 & 22. • Enclosure finished in Red High Performance Paint with ABS

Flare Assembly • 2 stage alarm, independently selectable second stage • Dual 20mm gland entries. Unit supplied with one approved

stopping plug and one dust cover • Monitoring facility (DC only) • Adjustable stainless steel ratchet bracket providing positive

setting • 32 selectable tones meeting international regulations • Sound selection via 5 way DIL switch • Temperature class T6 standard

TECHNICAL SPECIFICATION • IP 66 rated • Weight 4.5 Kg • Sound output 115dB(A) at 1 mtr • Relative Humidity 95% @ 40ºC • Certified Temperature Range -20ºC to +60ºC IIB and IIC Contact Sales Office for Low Temp. Unit –60°C to +60°C • Operating Voltage 24Vdc, 48Vdc 115Vac / 230Vac • Current consumption 24Vdc 300mA 48Vdc 160mA 115Vac 80mA 230Vac 45mA

MAIN FEATURES

Controlled document No.D7500-008-03 (CN100301) H/Data/ALARMS ENG/Data/SALES DATA/ Data Sheet Finals/YO9

MOUNTING Stainless steel mounting bracket provided. Holes to suit M6, Pitch 60mm.

Yodalex Standard Temperature Explosion Proof Sounder

Unit type YO9

IIB Gas Group

24Vdc

115Vac / 230Vac

APPROVAL SPECIFICATION European Standards EN60079-0:2006 EN60079-1:2004 ATEX Baseefa 08ATEX0189X Ex d IIC T6 Ex tD A21 IP66 Tamb (-20ºC to +60ºC) Baseefa 08ATEX0191X Ex d IIB T6 Ex tD A21 IP66 Tamb (-20ºC to +60ºC) International Standards IEC Ex08.0061X IEC Ex IIC IEC Ex08.0062X IEC Ex IIB Russian Approval UL APPROVAL PENDING GOST-R

316 (12.44’’)

142

(5.6

”)

Two 20mm gland entries. 1 fitted with ATEX approved stopping plug and 2nd dust cap

C l i f f o r d & S n e l l

210

(8.2

6”)

DIMENSIONS mm

Supply Voltage

ATEX

CONFIGURATOR

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

IIC

48Vdc

60 (2

.4”)

Certification

European

International

210 (8.26’’)

IECEx

Russian

GOST-R

michael ryan
LOGO
Page 6: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

• Break Glass and Push Button Call Point Station

• Light Weight Glass Reinforced Polyester (GRP) Ex d Enclosure

• Dual 20mm gland entries, one fitted with approved stopping plug (2 * M20 holes located at the top of the Call Point. Glands supplied separately) • Monitoring facility (DC only)

• ATEX / IECEx / GOST-R approved Gas and Dust

• Weather resistant high performance red paint finish as standard

• High intensity Red LED can be fitted as an optional extra to indicate operation. Available up to 24Vdc

• Meets the requirements of BS EN 54-11

• Break Glass version - Optional stainless steel Lift Flap Test Key provided as standard • Push Button version - Push to operate - Reset Key provided. Protection Flap as standard

TECHNICAL SPECIFICATION • IP 66 rated

• Weight Approx. 1Kg

• Relative Humidity 95% @ 40 degC

• Cetified Temp –55ºC to +70ºC • Voltage Up to 250V

• Switch Ratings DC 12 - 30V 5A (resitive) or 3A (Inductive)

• 30 - 50V 1A resitive or inductive

• AC 12 - 250V 5A resistive or inductive

• Suitable for Zones 1 & 2, 21 & 22.

• Up to 4 cable entries. Top Entries 2 * as standard.

• Internal earth continuity provided as standard

• 7 way 2.5mm terminal block mounted on a PCB.

• Single Pole change over switch supplied as standard and fitted directly onto the 7 way connector.

MAIN FEATURES

Controlled document No.D7489-01-02 (CN100301) \\My Documents\SALES DATA\data

MOUNTING Via holes through the Back Box. See Installation Instructions.

Unit type APPROVAL SPECIFICATION

C l i f f o r d & S n e l l

DIMENSIONS (mm)

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

Manual Call Points Yodalex

Break Glass

Switches Single Pole

Double Pole

Additional Options (User to specify resistor & diode values)

Lift FLap End Of Line Resistor In line Resistor IN Line & EOL resistor

Push Button

CONFIGURATOR

Break Glass (BG)

Push Button (PB)

Explosion Proof

132.5 (5.2”)

74 (2.9”)

132.5 (5.2”)

98 (3.9”)

A B

C D

Duty Label (Customer to specify wording)

Tag Label (Customer to specify wording)

LED

Labels

Entries 2 * M20 top entries A+B standard

(Suffix A = AC or D = DC. Example SPD = single pole dc switch)

Finish Red (standard). (Other options upon application)

Standards for Manual Call Points European Standards (ATEX) EN60079-0:2006 & EN60079-1:2007 EN61241-0:2004 & EN61241-1:2004 Break Glass Baseefa08ATEX0269 Ex II2 GD Ex tD A21 (Tamb –55°C to +70°C) Push Button Baseefa08ATEX0269 Ex II2 GD EX tD A21 (Tamb –55°C to +70°C) International Standards (IECEx) IEC60079-0:2004 Edition 4 & IEC60079-1:2007 Edition 6 IEC61241-0:2004 Edition 1 & IEC61241-1: 2004 Edition 1 Break Glass IECEx BAS 08.0089 Ex II2 GD Ex tD A21 (Tamb –55°C to +70°C) Push Button IECEx BAS 08.0089 Ex II2 GD Ex tD A21 (Tamb –55°C to +70°C) Russian Approval GOST-R

IECEx GOST-R

Certification

European

International

Russian

(For other options select positions of entries required and list)

ATEX

michael ryan
LOGO
Page 7: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

• BASEEFA approved • 2 stage alarm • Rugged construction • 32 selectable tones meeting international regulations • Meets PFEER sound signals recommended by UKOOA • Enclosure made from ABS flame retardant plastic • Monitoring facility • High sound output • Stainless steel fixings • Continuously rated • Sound selection via DIL switch

TECHNICAL SPECIFICATION

• Relative humidity 95% @ 40 deg C • Weight: YO3is 0.40Kg YO4is 0.49Kg YO5is 0.85Kg • For use in zones 0,1,2 • IP55 rated YO3, YO4 and YL4 • IP56 rated YO5 and YL5 • Volume control fitted on T4 class only • Operating voltage 12Vdc, 18Vdc or 24Vdc via barriers • Sound output YO3/4 100dB(A) @ 1 mtr Max YO5 105dB(A) @ 1 mtr Max • European models ISC & ISD • Operating temp –25deg C to +40deg C • II 1G Ex.ia IIC, T4 or T6 YO3,YO4 and YO5 • II 1G Ex.ia IIC, T4 YL4 and YL5 • Voltage upper limit controlled by barrier • D7277 Operating & Installation Instructions YO3,YO4 and YO5

• D7441 Operating & Installation Instructions I.S. Beacons The PFEER sound signals recommended by UKOOA are: General Alarm Sound Signal 15 Interrupted tone 1000 Hz PAPA Sound Signal 31 Reverse Sweep 1200-500 Hz Toxic Gas Sound signal 11 Continuous Tone 1000 Hz

MAIN FEATURES

Intrinsically Safe Audible and Visual Alarms

T4 Only YL4 YO3/4

Unit Type Sounder YO3

Opto-coupled

APPROVAL SPECIFICATION

European Standards Baseefa Certificate No. BAS02ATEX1190X YO3, YO4 and YO5 Baseefa certificate No. Baseefa08ATEX0194X YL4 and YL5 EN60079-0:2006 EN60079-11:2007

C l i f f o r d & S n e l l

YO3 YO4 YO5 YO5/YL5 YO3/YO4/YL4

Mounting: Via internal fixing holes

Sounder YO4

Sounder YO5

Temp Classification

Dim. For YO3 For YO5 Dim A 118 (4.7”) 169 (6.7”) Dim B 102 (4.0”) 153 (6.0”) Dim C 89 (3.5”) 134 (5.3”) Dim D 85 (3.4”) 128 (5.0”) Dim E 18 (0.7”) 23 (0.9”) Dim F 6 (0.2”) 8 (0.3”)

European Approved Barriers (See application notes)

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

DIMENSIONS mm

All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

CONFIGURATOR

Controlled document No. D7421-01-04 (CN100301)\\My Documents\ SALES DATA\ data sheets\Intrinsically Safe Sounders

ATEX

YO3 - YO4 / YL4 - YO5 / YL5

YO3

Mounting: Via external lugs 2 x Ø F fixing holes

A

D C B

C

E

YO4

YO5

YL4

YL5

M20 Cable mounting hole at Dim E

Models Y03 and YO5 Model YL5 (dimensions not shown same as for YO5)

57.5

(2.3

”)

88(3.5”) 88(3.5”)

9(0.4”)

276(

10.9

”)

90(3.5”) 81(3.2”)

81(3.2”) 90(3.5”)

180(

7.1”

)

Model YO4

Model YL4

YL5 YO5

Combination Unit - YL4

Combination Unit - YL5

YL4 YL5

michael ryan
LOGO
Page 8: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

• BASEEFA (ATEX) approved • 8 LED array allowing condition or status alert in flashing mode

• Continuously rated

• High light intensity

• Long life LED design

• Reliable and simple to install

• Red / White flame retardant ABS plastic enclosure

• Anti static enclosure and lens

• Up to 4 modules in any combination of lens colour ranging from Red, Amber, Green, Opal, Blue, Clear

• Each beacon should be wired independently.

TECHNICAL SPECIFICATION DIMENSIONS mm

MAIN FEATURES

Controlled document No. D7471-01-02 (CN100301) \\My Documents\SALES DATA\data sheets\

MOUNTING All units are supplied separate from the back box for ease of installation. The back box should be mounted to a reasonably flat surface or bulkhead. A gasket is supplied, should the surface be uneven, or if the unit is to be used in wet conditions. The installation is completed by fitting the beacon onto the back box by means of the supplied screws.

LINE MONITORING Monitoring via reverse polarity End of line resistor minimum 3K3 ohms 0.5 watts wire-wound or metal film type

CONFIGURATOR

Unit Type V4 LED Intrinsically Safe ‘Flashing’ Beacon

Supply Voltage

Amber

Red

Base Colours White

Red Flame

ORDERING INFORMATION Base Colours: RF = Red flame WN = White RN = Red Normal

All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

C l i f f o r d & S n e l l

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

Intrinsically Safe LED ‘Flashing’ Beacons

• For use in Zones 0, 1 and 2

• Operating voltage 12Vdc, 18Vdc, 24Vdc via ATEX approved barriers • Operating temp range –20 to + 40deg C

• Storage temp range –40 to + 70deg C

• Relative humidity 90% @ 40deg C

• IP65 rated

• Flash rate 1 per second

• Weight: Single 0.15 Kg, Double 0.3 Kg, Triple 0.45 Kg, Quad 0.6 Kg

• EEx ia IIC T4

APPROVAL SPECIFICATION ATEX DIRECTIVE - 9/94/EC EN 60079-0:2004 (EN50014:1997 + Amendments 1 & 2) EN60079 –1:2004 (EN50020:2002) EN50284:1999 Baseefa certificate No. BAS05ATEX0075

12, 18 & 24Vdc

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email:[email protected] Web Site: www.cliffordandsnell.com

Intrinsically Safe ‘Flashing’ Beacons

2nd

3rd

4th

1st

90 (3.5”)

90 (3.5”)

90 (3.5”)

90 (3.5”)

90 (3.5”)

Green Opal Blue Clear

1st 2nd

3rd 4th

1st 1st

2nd 2nd

1st

3rd

Depth = 81 (3.2”) Single Double

Triple

Quad

Number of Modules (leave blank if single unit) or 2,3 or 4

Triple Quadruple

X

ATEX

Yodac

Single Double

Lens Colours

Red Normal

michael ryan
LOGO
Page 9: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

• BASEEFA (ATEX) approved

• 8 LED array allowing condition or status alert in ‘on or off ’ mode

• Continuously rated

• High light intensity

• Long life LED design

• Reliable and simple to install

• Red / White flame retardant ABS plastic enclosure

• Anti static enclosure and lens

• Up to 4 modules in any combination of lens colour ranging from Red, Amber, Green, Opal, Blue, Clear

• Each beacon should be wired independently.

TECHNICAL SPECIFICATION DIMENSIONS mm

MAIN FEATURES

Controlled document No. D7472-01-02 (CN100301) \\My Documents\SALES DATA\data sheets\Yodac

MOUNTING All units are supplied separate from the back box for ease of installation. The back box should be mounted to a reasonably flat surface or bulkhead. A gasket is supplied, should the surface be uneven, or if the unit is to be used in wet conditions. The installation is completed by fitting the beacon onto the back box by means of the supplied screws.

LINE MONITORING Monitoring via reverse polarity End of line resistor minimum 3K3 ohms 0.5 watts wire-wound or metal film type

CONFIGURATOR

Unit Type V4 LED Intrinsically Safe ‘Status’ Beacon

Supply Voltage

Amber

Red

Lens Colours

Base Colours White

Red Flame

ORDERING INFORMATION Base Colours: RF = Red flame WN = White RN = Red Normal

C l i f f o r d & S n e l l

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

Intrinsically Safe LED ‘Status’ Beacons

• For use in Zones 0, 1 and 2

• Operating voltage 12Vdc, 18Vdc, 24Vdc via ATEX approved barriers

• Operating temp range –20 to + 40deg C

• Storage temp range –40 to + 70deg C

• Relative humidity 90% @ 40deg C

• IP65 rated

• Weight: Single 0.15 Kg, Double 0.3 Kg, Triple 0.45 Kg, Quad 0.6 Kg

• EEx ia IIC T4

APPROVAL SPECIFICATION ATEX DIRECTIVE - 9/94/EC EN60079-0:2004 (EN50014:1997 + Amendments 1 & 2) EN60079-1:2004 (EN50020:2002) EN50284:1999 Baseefa certificate No. BAS05ATEX0075

12, 18 & 24Vdc Via ATEX approved barriers

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

Intrinsically Safe ‘Status’ Beacons

2nd

3rd

4th

1st

90 (3.5”)

90 (3.5”)

90 (3.5”)

90 (3.5”)

90 (3.5”)

Green Opal Blue Clear

1st 2nd

3rd 4th

1st 1st

2nd 2nd

1st

3rd

Depth = 81 (3.2”) Single

Double

Triple

Quad All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

Number of Modules (leave blank if single unit) or 2,3 or 4

Single

Triple Quadruple

Double

X

ATEX

Yodac

Red Normal

michael ryan
LOGO
Page 10: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

• 2 stage alarm

• High sound output

• 3 wire polarised DC and AC, or 2 wire bi-polar for DC only

• Independently selectable second stage

• Complies with BS 5839

• Choice of 6 lens colours: Amber (A), Red (R), Green (G), Opal (O), Blue (B) and Clear (C) made from flame retardant polycarbonate plastic • Continuously rated

• Flame retardant ABS plastic enclosure

• Strobe - 2.5 and 5.0 joule.

• Stainless steel fixings

• 32 selectable tones meeting international regulations

• Sound selection via DIL switch

TECHNICAL SPECIFICATION • Operating temperature –25 to +55 deg C

• Storage temperature –40 to +70 deg C

• Operating voltage 12Vdc, 24Vdc, 48Vdc (UL= 24Vdc only) 115Vac, 230Vac +/- 10% • DC second stage alarm signal is via polarised or 2 wire bi-polar connection • IP 54 rated as std, IP 65 (WR) to order

• Weight YO8 + Super dc = 2.90Kg ac = 3.28Kg YL8 + Super dc = 3.21Kg ac = 3.58Kg • Separate input and output terminals on YO8, optional on YL8

• Relative humidity 90% @ 40deg C

• Sound output YO8/YL8 Vdc 116dB(A) at 1 mtr

• Sound output YO8/YL8 Super 120dB(A) at 1 mtr

• Minimum current consumption 300mA The PFEER sound signals recommended by UKOOA are: General Alarm Sound Signal 15 Interrupted tone 1000 Hz PAPA Sound Signal 31 Reverse Sweep 1200-500 Hz Toxic Gas Sound signal 11 Continuous Tone 1000 Hz

MAIN FEATURES

Controlled document No. D7409-01-04 (CN100301) \\My Documents\SALES DATA\data sheets\Y08-YL8

MOUNTING The YO8/YL8 series alarm units should be mounted to a reasonably flat wall or bulkhead of suitable material using the lugs projecting from the side of the case. The lugs are bored 10mm on 250mm centres. The minimum recommended length of fixing screws is 30mm. To maintain the integrity of the weather seal, the cable must be fitted using a suitable sealed gland.

Unit type

12Vdc Supply Voltage

Red Flame

YO8

YL8/YL8 Super

LINE MONITORING (DC Only) - 3 Wire 2 stage or 2 wire single stage, monitor via reverse polarity - 2 Wire 2 stage i.e. bi-polar inputs, monitor via threshold (applied voltage <1V) End of line resistor. Minimum 3K3 ohm 0.5 watts, wire-wound or metal film type.

24Vdc 48Vdc 115Vac

Material

YO8/YL8 YO8/YL8 Super YL8 + Super YO8 + Super

DIMENSIONS mm

Unit type YL8

12Vdc 2.5 joules

Supply Voltage and Flash Energy

24Vdc 2.5 joules

24Vdc 5.0 joules

48Vdc 5.0 joules

115Vac 5.0 joules

230Vac 5.0 joules Lens Colour

Red Flame Material

SUPER Units

APPROVAL SPECIFICATION UL 1638, UL 464 C22.2 No. 205-M1983, CAN/ULC-5526-M87 BS EN 54-3 : 2001 incorporates amendment A1 : 2002 DIN EN 54, Teil 3 (10/01) VdS 2504 (12/96) VdS 2203 (03/01) VdS 2344 (12/05)

11 (0.4”)

269 (10.6”) 250 (9.8”)

2 x Dia 10 fixing holes

216

(8.5

”)

57.5

(2.3

”)

88 (3.5”)

YL ONLY

153 (6.0”)

230Vac

IP65 (std on UL units)

24 (0.9”)

SUPER Units

C l i f f o r d & S n e l l

CONFIGURATOR

M20 Cable Mounting hole

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

Industrial Audible and Visual Alarm Yodalarm & Yodalight

Certification USA/Canada

Certification USA/Canada Vdc Vdc

YO8 + Super

YL8 + Super Vac Vac

All dimensions quoted are approximate only and subject to change Without notice as are technical features resulting from continual development and improvement.

YO8/YO8 Super

KM91259

IP65 (std on UL units)

michael ryan
LOGO
Page 11: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

• 2 Stage alarm

• 3 wire polarised DC (Not additional voltage option) & AC, or 2 wire bi-polar for DC only.

• Choice of 6 lens colours: Amber (A), Red (R), Green (G), Opal (O), Blue (B) and Clear (C) made from flame retardant polycarbonate plastic • High sound output • Complies with BS 5839 • Low current consumption • Continuously rated • Robust, reliable and simple to install • Flame retardant ABS plastic enclosure • Strobe 2.5 and 5.0 joule • 32 selectable tones meeting international regulations • Sound selection via 5 way DIL switch • Stainless steel fixings

TECHNICAL SPECIFICATION • Operating temperature UL: -35ºC to +66ºC

• EN54-3 : -25ºC to +55ºC

• VdS: -25ºC to +40ºC

• Operating voltage 12Vdc, 24Vdc, 48Vdc 115Vac, 230Vac +/- 10% (12Vdc versions will produce approx. 6dB less output) • Additional voltage options (Sounders only) Combined 24Vdc and 48Vdc (BT). 110Vdc • Relative humidity 90% @ 40deg C

• Sound output 110dB(A) at 1 mtr

• IP54 rated as standard. IP65 rated (WR) to order.

• Weight: YO5 dc = 0.71Kg ac = 0.81Kg YL5 dc = 1.01Kg ac = 1.09Kg • Volume control allowing 18dB(A) adjustment

• Minimum current consumption 20mA. Sounder only

• Optional independent 2nd stage via second DIL switch (DC only)

MAIN FEATURES

Controlled document No. D7408-01-05 (CN100301) \\My Documents\SALES DATA\data sheets\Y05-YL5

MOUNTING The YO5/YL5 series alarm units should be mounted to a reasonably flat wall or bulkhead of suitable material using the lugs projecting from the side of the case. The lugs are bored 8mm on 153mm centres. The minimum recommended length of fixing screws is 25mm. To maintain the integrity of the weather seal, the cable entry must be fitted using a suitable sealed gland.

Unit Type

24Vdc

Supply voltage

Red Flame

YO5

All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

3 Wire, 2 stage or 2 wire, single stage: - monitor via reverse polarity 2 Wire, 2 stage i.e. bi-polar inputs: - monitor via threshold (applied voltage <1V) End of line resistor: - minimum 3K3 ohm, 0.5 watts, wire-wound or metal film type.

48Vdc

115Vac

230Vac

Material

YO5 Vdc YO5 Vac YL5 Vdc YL5 Vac

DIMENSIONS mm

12Vdc 2.5 joules Strobe supply Voltage and Flash Energy

24Vdc 2.5 joules

24Vdc 5.0 joules

48Vdc 5.0 joules

115Vac 5.0 joules

230Vac 5.0 joules Lens Colour

Red Flame Material

Optional Ind 2nd Stage DC Only

APPROVAL SPECIFICATION UL 1638, UL 464 C22.2 No. 205-M1983, CAN/ULC-5526-M87 BS EN 54-3 : 2001 incorporates amendment A1 : 2002 DIN EN 54, Teil 3 (10/01) VdS 2504 (12/96) VdS 2203 (03/01) VdS 2344 (12/05) VdS approval applies to selected models only. Contact sales for details - Cert. No. G28702 Germanischer Lloyd Approval. (YO5 only)

9 (0.4”)

169 (6.7”)

153 (6”)

2 x Ø8 fixing holes.

134

(5.3

”)

57.5

(2.3

”)

88 (3.5”)

YL ONLY

128 (5.0”)

24Vdc and 48Vdc 110Vdc

IP65 (std on UL units)

C l i f f o r d & S n e l l

IP65 (std on UL units)

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

CONFIGURATOR

M20 Cable Mounting hole

23 (0.9”)

Industrial Audible and Visual Alarm Yodalarm & Yodalight

Certification USA/Canada

Certification USA/Canada

Unit Type YL5

YL5 YO5

KM91259

VdS

G L

12Vdc ( NOT BS EN 54-3 )

Optional Ind 2nd Stage DC Only LINE MONITORING (DC ONLY) excludes additional voltage options

Certification Vds (dc only)

Certification Vds (dc only)

michael ryan
LOGO
Page 12: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

• 2 Stage alarm

• High sound output

• 3 wire polarised DC (Not additional voltage option) & AC, or 2 wire bi-polar for DC only.

• 3 wire AC second stage control

• Complies with BS 5839

• Strobe 2.5 and 5 joule.

• Choice of 6 lens colours: Amber (A), Red (R), Green (G), Opal (O), Blue (B) and Clear (C) made from flame retardant polycarbonate plastic • Red / white flame retardant ABS plastic enclosure.

• Continuously rated

• Flush mounting base available

• 32 selectable tones meeting international regulations

• Sound selection via 5 way DIL switch

TECHNICAL SPECIFICATION • Operating temperature UL: -35ºC to +66ºC

• EN54-3: -25ºC to +55ºC

• VdS: -25ºC to +40ºC

• Operating voltage 12Vdc, 24Vdc, 48Vdc 115Vac, 230Vac +/- 10% (12Vdc versions will produce approx. 6dB less output) • Additional voltage options (Sounders only) Combined 24Vdc and 48Vdc (BT) 110Vdc • Relative humidity 95% @ 40 deg C

• Sound output 106dB(A) at 1 mtr

• IP54 rated as standard. Rated IP65 (WR) to order

• Weight: YO4 dc = 0.25Kg ac = 0.35Kg YL4 dc = 0.51Kg ac = 0.57Kg • Volume control allowing 18dB(A) adjustment

• Minimum current consumption 20mA

• Optional independent 2nd stage via second DIL switch (DC only)

MAIN FEATURES

Controlled document No. D7406-01-05 (CN100301) \\My Documents\SALES DATA\data sheets\Y04-YL4

MOUNTING The YO4/YL4 series alarm should be mounted to a reasonably flat wall or bulkhead of suitable material using the internal fixing holes. The recom-mended fixing screws are dia 4.5 mm max x 20 mm long. To maintain the integrity of the weather seal, the cable must be fitted using a suitable sealed gland.

Unit type

24Vdc

Supply Voltage

Red Flame

YO4

All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

YL4

LINE MONITORING (DC Only) excludes additional voltage options 3 Wire, 2 stage or 2 wire, single stage: - monitor via reverse polarity 2 Wire, 2 stage i.e. bi-polar inputs: - monitor via threshold (applied voltage <1V) End of line resistor: - minimum 3K3 ohm, 0.5 watts, wire-wound or metal film type.

48Vdc

115Vac

230Vac

Material Red Normal White

YO4 Vdc YO4 Vac YL4 Vdc YL4 Vac

DIMENSIONS mm

12Vdc 2.5 joules Strobe Supply Voltage and Flash Energy

24Vdc 2.5 joules 24Vdc 5.0 joules 48Vdc 5.0 joules 115Vac 5.0 joules 230Vac 5.0 joules

Lens Colour Red Flame Material Red Normal White

90 (3.5”)

81 (3.2”)

183 (7.2”)

APPROVAL SPECIFICATION UL 1638, UL 464 C22.2 No. 205-M1983, CAN/ULC-5526-M87 BS EN 54-3 : 2001 incorporates amendment A1 : 2002 DIN EN 54, Teil 3 (10/01) VdS 2504 (12/96) VdS 2203 (03/01) VdS 2344 (12/05) - Cert. No.G28702 VdS approval applies to selected models only. Contact sales for details

C l i f f o r d & S n e l l

CONFIGURATOR

IP65 (std on UL units) Optional Ind 2nd Stage DC Only

IP65 (std on UL units) Optional Ind 2nd Stage DC Only

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

Industrial Audible and Visual Alarm Yodac

24Vdc and 48Vdc

110Vdc

Certification USA/Canada

Certification USA/Canada

Unit Type YL4

KM91259

YO4

VdS

12Vdc (NOT BS EN 54-3)

Certification Vds (DC Only)

Certification Vds (DC Only)

michael ryan
LOGO
Page 13: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

• 2 stage alarm

• 3 wire polarised DC (Not additional voltage option) & AC, or 2 wire bi-polar for DC only

• 3 wire AC second stage control

• Complies with BS 5839

• Flame retardant ABS plastic enclosure

• Stainless steel fixings

• Continuously rated

• 32 Selectable tones meeting international regulations

• Sound selection via 5 way DIL switch

TECHNICAL SPECIFICATION • Operating temperature range –25 to +55 deg C

• Storage temperature range –40 deg C to +70 deg C

• Operating voltage 12Vdc, 24Vdc, 48Vdc 115Vac, 230Vac +/- 10% (12Vdc versions will produce approx. 6dB less output)

• Additional voltage options (Sounders only) 24Vdc and 48Vdc (BT) 110Vdc

• Relative humidity 90% @ 40deg C

• Sound output 100dB(A) @ 1mtr

• Weight dc = 0.32Kg ac = 0.39Kg

• IP 54 rated as standard. Rated IP 65 (WR) to order

• Volume control allowing 18dB(A) adjustment

• Minimum current consumption 20mA

• Optional independent 2nd stage via second DIL switch

DIMENSIONS mm

MAIN FEATURES

Controlled document No. D7405-01-04 (CN100301) \\My Documents\SALES DATA\data sheets\Y03

MOUNTING The YO3 series alarm should be mounted to a reasonably flat wall or bulkhead of suitable material using the lugs projecting from the side of the case. The lugs are bored 6mm clearance on 102mm centres. The minimum recommended length of fixing screws is 25mm. To maintain the integrity of the weather seal, the cable must be fitted using a suitable sealed gland.

Unit type

Material Red Flame

118 (4.7”)

Industrial Audible Alarm Yodalarm

YO3

All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

102 (4”)

89 (3.5”) 85 (3.4”)

89 (3.5”)

18 (0.7”) M20 Cable Mounting hole

3 Wire, 2 stage or 2 wire, single stage: - monitor via reverse polarity 2 Wire, 2 stage i.e. bi-polar inputs: - monitor via threshold (applied voltage <1V) End of line resistor: - minimum 3K3 ohm, 0.5 watts, wire-wound or metal film type.

2 x Ø6 Fixing Holes

APPROVAL SPECIFICATION UL 464 C22.2 No.205-M1983 BS EN 54-3 : 2001 incorporates amendment A1 : 2002 DIN EN 54, Teil 3 (10/01) VdS 2504 (12/96) VdS 2203 (03/01) VdS 2344 (12/05) Cert. No. G28702

C l i f f o r d & S n e l l

IP 65 (std on UL units)

CONFIGURATOR

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

KM

24Vdc and 48Vdc

110Vdc

Certification USA/Canada

Vdc Vac

Supply voltage

VdS

12Vdc (NOT BS EN 54-3)

24Vdc 48Vdc

115Vac

230Vac

LINE MONITORING (DC ONLY) excludes additional voltage options

Optional Independant 2nd Stage DC only (Standard on UL Models)

Certification Vds (DC Only)

michael ryan
LOGO
Page 14: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

• Up to 8 individually selectable stages • 32 selectable tones meeting international regulations • Each stage is determined by a 5 way DIL switch (For switch settings see Tone Table Page 22) • Complies with BS 5839 • Red flame retardant ABS plastic enclosure. • Continuously rated • Can be used in conjunction with the V4 range of beacons to form a combination Sounder/Strobe

MAIN FEATURES

Controlled document No. D7473-01-01 (CN100047)\\My Docs\SALES DATA\data sheets\

MOUNTING

The YO4/YO5/YO8 series alarm should be mounted to a reasonably flat wall or bulkhead of suitable material using the internal fixing holes for YO4 or the external lugs for YO5/YO8. Recommended fixing screws : - for YO4 = 4.5 mm max dia. x 20 mm long, for YO5 = 8mm max dia. x 25mm long and for YO8 = 10mm max dia.x 30mm long. To maintain the integrity of the weather seal, the cable must be fitted using a suitable sealed gland. Unit Type

24Vdc Supply Voltage

Red Flame

YO4

All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

YO4

LINE MONITORING (DC Only) 2 wire polarised, single stage, monitor via reverse polarity. End of line resistor, minimum 3K3 ohm, 0.5 watts, wire-wound or metal film type.

Material

YO4

DIMENSIONS mm

90 (3.5”)

C l i f f o r d & S n e l l

TECHNICAL SPECIFICATION

• Operating temperature –25 to +55 deg C • Storage temperature –40 to +70 deg C • Operating voltages +/- 10% YO4 dc only YO5 dc or ac YO8 dc or ac • Relative humidity 95% @ 40 deg C • IP65 (WR) as standard • Weight YO4 0.22Kg YO5 0.55Kg YO8 2.50Kg

CONFIGURATOR

IP65 Standard

Multi-Stage

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

Multi-Stage Alarms

YO5

9 (0.4”)

169 (6.7”)

153 (6”)

2 x Ø8 fixing holes.

YO4 YO5 YO5

YO5

YO8

81 (3.2”)

90 (3.5”)

128 (5.0”)

134 (5.3”)

269 (10.6”)

250 (9.8”)

219 (8.6”)

2 x Ø10 fixing holes

159(6.3”)

11 (0.4”)

YO4 YO5 YO8

YO8 YO8

YO8

48Vdc 115Vac

230Vac

michael ryan
LOGO
Page 15: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

• Continuously rated

• Strobe 2.5 and 5 joule

• High flash intensity

• 360 degree visibility

• Reliable and simple to install

• Complements audible alarm system

• Flush mounting base available

• Red / White flame retardant ABS plastic enclosure

• Lens colours: Amber (A), Red (R), Green (G), Opal (O), Blue (B) and Clear (C) made from flame retardant polycarbonate plastic. • Steady lamp version available upon request

TECHNICAL SPECIFICATION • Operating temperature range UL: -35ºC to +66ºC

• EN54-3: -25ºC to +55ºC

• VdS: -25ºC to +40ºC • Relative humidity 90% @ 40ºC

• IP65 Rated

• Weight: dc = 0.26Kg ac = 0.25Kg

• Operating voltage 12Vdc or 24Vdc or 48Vdc 115Vac or 230Vac • Current consumption (Flash Energy). See design data below.

DIMENSIONS mm

MAIN FEATURES

Controlled document No. D7410-01-05 (CN100301)\\My Documents\SALES DATA\data sheets\V4

MOUNTING All units are supplied separate from the back box for ease of installation. The back box must be mounted with the two cable entries at the top or bottom. The back box should be mounted to a reasonably flat surface or to a standard wiring box, using any of the internal mounting holes. A gasket is supplied, should the surface be uneven, or if the unit is to be used in wet conditions. To maintain the integrity of the weather seal, the cable must be fitted using a suitable sealed gland. The installation is completed by fitting the beacon onto the back box by means of the supplied screws.

LINE MONITORING Monitoring via reverse polarity End of line resistance. Minimum 3K3 ohms 0.5 watts wire-wound or metal film type

90 (3.5”)

90 (3.5”)

81 (3.2”)

49 (1.9”)

Unit Type

12Vdc 2.5 joules

24Vdc 2.5 joules

Strobe supply Voltage and Flash Energy

Lens Colours

Base Colours

All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

C l i f f o r d & S n e l l

Operating Voltage 12Vdc 24Vdc 48Vdc 115Vac 230Vac Flash Energy (Joules) 2.5 2.5 - 5 5 5 5 Light output, opal lens Candela sec 4.5 4.5 - 14 14 14 14 Current consumption (mA) 300 150 - 250 135 130 70 CAUTION: High voltages are present within the beacon when operational.

DESIGN DATA

24Vdc 5.0 joules

48Vdc 5.0 joules

115Vac 5.0 joules

230Vac 5.0 joules

Red Flame

Red Normal

White APPROVAL SPECIFICATION UL 1638 CAN/ULC-S526-M87 DIN EN 54, Teil 3 (10/01) VdS 2504(12/96) VdS 2203(03/01) VdS 2344(12/05) - Cert.No.G28714

DC Type AC Type

CONFIGURATOR

Clifford & Snell a division of Signature Industries part of the Digital Angel Corporation

Xenon Strobe - Visual Flashing Alarm Yodac

Strobe

Certification USA/Canada

VdS

Certification Vds (DC Only)

michael ryan
LOGO
Page 16: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

• For use as a Safe Area visual alarm

• 8 or 12 LED array allowing option of ‘status’ or ‘flashing’ mode. See CONFIGURATOR for coding

• Continuously rated

• High light intensity

• Long life LED design

• Reliable and simple to install

• Red / White flame retardant ABS plastic enclosure

• Up to 4 modules in any combination of lens colour ranging from Red, Amber, Green, Opal, Blue, Clear

• Each beacon should be wired independently.

TECHNICAL SPECIFICATION DIMENSIONS mm

MAIN FEATURES

Controlled document No. D7474-01-02 (CN100301) \\My Documents\SALES DATA\ data sheets\Yodac

MOUNTING All units are supplied separate from the back box for ease of installation. The back box should be mounted to a reasonably flat surface or bulkhead. A gasket is supplied, should the surface be uneven, or if the unit is to be used in wet conditions. The installation is completed by fitting the beacon onto the back box by means of the supplied screws.

LINE MONITORING Monitoring via reverse polarity End of line resistor: - minimum 3K3 ohms, 0.5 watts wire-wound or metal film type.

CONFIGURATOR

C l i f f o r d & S n e l l

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

LED ‘Flashing’ & ‘Status’ Beacons

Yodac

• Operating voltage 12Vdc/24Vdc

• Operating temp range –20 to + 40deg C

• Storage temp range –40 to + 70deg C

• Relative humidity 90% @ 40deg C

• IP65 rated

• Weight: - Single = 0.15 Kg Double = 0.3 Kg Triple = 0.45 Kg Quad = 0.6 Kg

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

‘Flashing’ & ‘Status’ Beacons

2nd

3rd

4th

1st

90 (3.5”) 90 (3.5”)

90 (3.5”)

1st 1st

2nd 2nd

1st

3rd

Depth = 81 (3.2”)

Single Double

Triple

Quad All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

Supply Voltage

Amber

Red Lens Colours

Base Colours

White

Red Flame

Green Opal Blue Clear

1st 2nd

3rd 4th

Number of Modules (leave blank if single unit)

Single

Triple Quadruple

Double

Red Normal

24Vdc

12Vdc

Number of LED’s 8 Array

12 Array

‘Flashing’

‘Status’

Unit type V4 LED

90 (3.5”)

90 (3.5”)

michael ryan
LOGO
Page 17: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

• Versatile compact sounder

• Low current consumption

• High sound output

• 2 stage alarm by 2 wire bi-polar and 3 wire polarised control

• Continuously rated

• Complies with BS 5839

• Easy installation

• For 3 wire 2 stage alarm systems, line integrity maybe monitored via reverse polarity

• 32 selectable tones meeting international regulations

• Sound selection via 5 way DIL switch

• Red flame retardant ABS plastic enclosure

TECHNICAL SPECIFICATION • Operating temperature –25 to +40 deg C

• Storage temperature –40 to +70 deg C

• Operating voltage 10 - 30Vdc

• Relative humidity 95% @ 40 deg C

• IP65 rated

• Cable gland entry must be suitably sealed

• Weight 0.28Kg

• Sound output 104dB(A) @ 1 mtr

• Volume control giving 18dB(A) adjustment

• Minimum current consumption 20mA

MAIN FEATURES

Controlled document No. D7412-01-03 (CN100047)\\My Documents\SALES DATA\data sheets\CARILLON

MOUNTING The Carillon alarm units should be mounted to a reasonably flat wall or bulkhead of suitable material using the internal fixing holes (mounting gasket supplied). The recommended fixing screws are dia 4.5max x 20mm long. To maintain the integrity of the weather seal, the cable must be fitted using a suitable sealed gland.

Electronic Sounder

LINE MONITORING (DC Only) 3 Wire 2 stage or 2 wire single stage, monitor via reverse polarity 2 Wire 2 stage i.e. bi-polar inputs, monitor via threshold (applied voltage <1V) End of line resistor: - minimum 3K3 ohm, 0.5 watts, wire-wound or metal film type.

DIMENSIONS mm

C l i f f o r d & S n e l l

All dimensions are approximate only and subject to change without notice as are technical features resulting from continual development and improvement

100 (3.9”)

110

(4.3

”)

90 (3.5”)

80 (3.2”)

50 (2

”)

APPROVAL SPECIFICATION

BS EN 54-3 : 2001 incorporates amendment A1 : 2002

CONFIGURATOR

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

Unit Type

Supply Voltage 10 - 30Vdc

Material

Carillon

Red Normal

KM91259

michael ryan
LOGO
Page 18: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

• General purpose sounder for indoor use only

• Single stage alarm

• Choice of 4 sound signals

• Suitable as bedhead alarm

• Surface or flush mounting base available

• Red / white flame retardant ABS plastic enclosure

• Complies with BS 5839

• Low current consumption

TECHNICAL SPECIFICATION • Operating temp range –30 to +55 deg C

• Storage temp –40 to +70 deg C

• Operating voltage 24Vdc +/-10%

• Relative humidity 95% @ 40 deg C

• Approximate weight 0.125 Kg

• IP44 rated

• Sound output 96dB @ 1 mtr

• Minimum current consumption 13mA

MAIN FEATURES

Controlled document No. D7411-01-03 (CN100047)\\My Documents\SALES DATA\data sheets\QUADALARM

MOUNTING The FP series alarm units should be mounted to a reasonably flat wall or bulkhead of suitable material using the internal fixing holes. The recommended fixing screws are dia 4.5max x 20mm long.

Face Plate - Electronic

FLUSH TYPE

LINE MONITORING (DC Only) Line monitoring via reverse polarity End of line resistor: - minimum 3K3 ohm, 0.5 watts, wire-wound or metal film type.

Unit Type Yodac Range

Supply Voltage 24Vdc

Base Colour

Surface Mounting

Flush

TONE TABLE

First Sound Frequency Rep. Selection Link Sound mA Stage Description Rate A+C B+D Signal

1 Alternate two-tone 800 -1000 0.5 Y Y 96 20 2 Continuous note 1000 - Y - 95 19 3 Interrupted tone 1000 0.5 - - 95 18 4 Alternate two-tone 430 - 470 1.0 - Y 93 13

Sound output level and current consumption values are for 24Vdc input supply. Values for 12Vdc are - 6dB(A) and 50% mA of 24Vdc values. Sound output values are measured at 1 mtr. Red Normal

White

Face Plate Sounder ORDERING INFORMATION Base Colours: RN = Red normal WN = White

C l i f f o r d & S n e l l

All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

APPROVAL SPECIFICATION BS EN 54-3 : 2001 incorporates amendment A1 : 2002

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

CONFIGURATOR

SURFACE TYPE

Flush Type will interface with standard electrical back box.

Yodac

92 (3.6”)

92 (3

.6”)

44

(1.7

”)

21 (0.8”) 23 (0.9”)

KM91259

DIMENSIONS mm

michael ryan
LOGO
Page 19: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

• Fully integrated Sounder Strobe Combination Unit

• Single stage alarm

• Unique compact design

• Suitable for indoor use only

• Continuously rated

• Suitable as bedhead alarm

• Volume control as standard

• Low current consumption

• Separate light, Sound or Combination function

• Parabolic reflector produces high intensity light output (3J)

• Complies with BS5839

• Optional lens colours are available in Red, Amber and Clear Polycarbonate plastic

• Red/White flame retardant ABS plastic enclosure.

• 32 Selectable tones meeting international regulations

• Sound selection via DIL switch

TECHNICAL SPECIFICATION

• Relative humidity 90% @ 40 deg C

• Operating voltage 24Vdc +/- 10%

• Operating temperature –25 deg C to +40 deg C

• Storage temperature –40 deg C to +70 deg C

• Light output 40 candela (effective) on x-axis

• Flash rate 1 per second

• Sound output 100dB(A) max @ 1mtr

• Minimum current consumption - Strobe 60mA

• Minimum current consumption - Sounder 20mA

• Weight 0.29 Kg

• Separate in - out supply connections for looping to other YL2 units

DIMENSIONS mm

MAIN FEATURES

Controlled document No. D7395-01-03 (CN100047) \\My Documents\SALES DATA\Data Sheets\YL2

MOUNTING

The YL2 should be mounted to a reasonably flat wall or bulkhead of suitable material, using any of the internal mounting holes. The instal-lation is completed by fitting the unit onto the back box by means of the screws provided.

105 (4.1”)

105 (4.1”)

Unit Type

24Vdc Supply Voltage

Red

Amber

Clear

Lens Colours

Material

19 (0.8”)

45 (1.8”) 36 (1.4”) 20 Dia cable entry hole

Audible and Visual Alarm

YL2

All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

NOTE: FOR INDOOR USE ONLY

C l i f f o r d & S n e l l

APPROVAL SPECIFICATION BS EN 54-3 : 2001 incorporates amendment A1 : 2002

Red Normal

White

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

CONFIGURATOR

KM91259

michael ryan
LOGO
Page 20: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

• Choice of two sound signals

• Surface or flush mount available

• Red / white flame retardant ABS plastic enclosure

• High sound output

• Low current consumption

• Continuously rated

• Complies with BS5839

TECHNICAL SPECIFICATION • Operating voltage 24Vdc +/-10%

• Operating temp range –25 to +55 deg C

• Relative humidity 95% @ 40 deg C

• IP54 rated

• Sound output 24Vdc 100dB @ 1 mtr (12Vdc versions will produce approx. 6dB less output)

• Current consumption 24Vdc 30mA

• Weight 0.25Kg

MAIN FEATURES

Controlled document No. D7415-01-03 (CN100047)\\My Documents\SALES DATA\data sheets\ Type LC

MOUNTING The Low Cost Sounder series alarm units should be mounted to a reasonably flat wall or bulkhead of suitable material using the internal fixing holes (mounting gasket supplied). The recommended fixing screws are dia 4.5 mm max x 20 mm long.

90 (3.5”)

Unit type

24Vdc Supply voltage

Electronic Sounder Yodac

Yodac

All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

FOR MONITORING SOUNDER LINES BY SUPPLY For monitoring Negative Vdc to terminal 1 Positive Vdc to terminal 2 For continuous tone alarm signal Reverse polarity Polarised input available by cutting LINK

32 (1.3”)

Base Colour Red Normal

White

Low Cost Sounder

DIMENSIONS mm

C l i f f o r d & S n e l l

49 (1.9”)

90 (3.5”)

Base Style Surface

Flush

FOR MONITORING SOUNDER LINES BY THRESHOLD VOLTAGE METHOD For monitoring, Vdc applied must be less than 1 volt For alarm signal, connect as described below observing polarity appropriate to alarm selected.

TONE TABLE Continuous tone (800Hz) Positive Vdc to terminal 1 Negative Vdc to terminal 2 Alternative tones (800Hz/1000Hz) Reverse polarity

Surface

49 (1.9”)

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

CONFIGURATOR

ORDERING INFORMATION Base Colours: RN = Red normal WN = White

9 (0.4”)

Flush Type will interface with standard electrical back

Flush

michael ryan
LOGO
Page 21: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com

Controlled document No. D7420-01-03 \\My Documents\SALES DATA\data sheets\Keyswitch-Mains Adapter and Door Holder

Keyswitch (KS) Mains Adapter (MA) Door Holder (DH)

C l i f f o r d & S n e l l

MOUNTING These units should be mounted to a reasonably flat surface of suitable material using internal fixing holes. The recommended fixing screws are dia 4.5mm max x 20mm long. When installing the Door Holder unit, ensure the armature is mounted in line and secured using the screws provided.

DH KS MA DH DC Version DH AC Version

All dimensions quoted are approximate only and subject to change without notice as are technical features resulting from continual development and improvement.

Unit Type

Keyswitch

Mains Adapter

Mains Adapter

Keyswitch

Colour Red Normal

White

Supply Voltage

Yodac Range

Door Holder

Colour

24Vdc

230Vac

Door Holder

White

DIMENSIONS mm

Keyswitch Type (KS)

Door Holder Type (DH)

Mains Adapter Type (MA)

DATA APPLICABLE TO ALL UNITS: • Temperature range Operating -25 to +55 deg C Storage -40 to +70 deg C • Relative humidity 95% at 40 deg C

• For indoor use only

• Red / white flame retardant ABS plastic enclosure

• Terminal capacity CSA-2.5 mm2

MAIN FEATURES AND SPECIFICATIONS Keyswitch type KS

• Suitable for security of circuit operation

• Flush mounting base available • Switch action Single pole changeover • Contact rating non inductive (A) 2 at 240Vac 4 at 28Vdc • Number of keys supplied 2

• Approximate weight (g) 120

MAIN FEATURES AND SPECIFICATIONS Mains Adapter type MA • An adapter to enable 12Vdc and 24Vdc to be powered from 230Vac mains supply • Compact design

• Selectable output

• Input supply 230Vac 50/60 Hz

• Output supply 12Vdc or 24Vdc selectable

• Internal fuse 500(mA)

• Maximum output current 300(mA) 12V setting 200(mA) 24V setting

• Approximate weight 290(g)

MAIN FEATURES AND SPECIFICATIONS Door Holder type DH • An electromagnetic door holder which can be electrically released in

the event of fire

• Test / override button

• Integral reset

• Supplied complete with armature plate • Operating voltage 24Vdc, 230Vac 50/60 Hz • Voltage tolerance dc +/- 25%, ac +/- 10% • Current consumption dc 80mA, ac 60mA • Holding force 11.3Kg (25lb) • Maximum residual force 0.8Kg (1.8lb) • Approximate weight 0.41 Kg dc 0.45 Kg ac • IP44 Rated

Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

CONFIGURATOR

230Vac

Switching Voltages

Yodac

90 (3.5”) All units

90 (3.5”) All units

41 (1.6”) MA

46 (1.8”) KS

48 (1.9”) DH

michael ryan
LOGO
Page 22: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Controlled document No. D7488-01-01 (CN100047)\\My Docoments\ SALES DATA\DATA SHEETS\ Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

EarthConnection

To Next Sounder

43

2TB

31

34

TB22

Sound Selection

Pressure Unit Connector

x

yTB1

to next strobe

14

32

1

0vSounder& Strobe

Sounder+24v dc Earth

Strobe+24v dc

LK2 removed (link 24v dc)

LK1 (link 0v)

(On other side of PCB)

(On other side of PCB)

SW1 SW2

AC ALARM CONNECTION AND SOUND SIGNAL SELECTION See Tone Table for switch settings

STANDARD DC ALARM CONNECTION AND SOUND SIGNAL SELECTION

See Tone Table for switch settings

Two stage alarm by third core. Strobe shown with common 0V. Line monitoring by reversal. Select alarm stage 1 on SW1. Select alarm stage 2 on SW2.

NOTE: - The two stage control always operates as follows: - The first stage sounds by supplying volts to a unit via control switch ’x’. This switch remains on and the second stage signal is controlled by switching volts to the third terminal via switch ’y’.

For other options and full operating and installation instructions see website www.cliffordandsnell.com

SOUNDER

STROBE

N

SW—A SOUNDER 2nd STAGE

CONTROL PANEL

TB1

TB2

TB3

TB4

TB1 TB2 TB3 TB4

TO NEXT SOUNDER AND STROBE

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com C l i f f o r d & S n e l l

Wiring Diagrams

TYPICAL CONNECTION DIAGRAMS FOR YODALEX FLAMEPROOF AUDIBLE AND VISUAL ALARMS MODELS V6 - YO6 - YL6

michael ryan
LOGO
Page 23: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Controlled document No. D7491-01-01 (CN100047)\\My Docoments\ SALES DATA\DATA SHEET\ Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com C l i f f o r d & S n e l l

Wiring Diagrams

XENON STROBE - VISUAL ALARM - YODAC - MODEL V4 The power supply for the Xenon Beacons (STROBES) is via the on-board terminal block. For DC: - Terminal (+) for +ve and Terminal (-) for 0V. For AC: - Terminal (L) for LIVE and Terminal (N) for NEUTRAL. CAUTION: - High voltages are present within the beacon when operational.

1 2 3 4 5

1 2 3 4ON

1 2 3 4 5

1 2 3 4ON

ELECTRONIC SOUNDER - MODEL CARILLON

0V

+ve

(X)

(Y)

(X) 0V +ve (Y) +ve 0V

VOLUME CONTROL VOLUME CONTROL

LED FLASHING AND STATUS BEACONS - MODEL V4LED

Sound signal selection is made by setting of the PCB mounted switches. For switch settings see the Tone Table on page 21.

MULTI - STAGE ALARMS - MODELS YO4 - YO5 - YO8

The power supply for the Multi-Stage Alarms is via the on-board terminal block. DC only: - Terminal (+) for +ve and Terminal (-) for 0V.

For all stages connect 0v to terminal 1. For 1st Stage connect +ve to terminal 2. For 2nd Stage connect +ve to terminal 3, etc., up to 8th Stage with +ve connected to terminal 9. NOTE: ONLY APPROPRIATE TWO WIRES ARE REQUIRED TO BE CONNECTED FOR EACH STAGE FOR AC UNITS 0V = NEUTRAL and +ve = LIVE For Sound Selection all stages have independently selectable 5 way dil switches. SW1 = Stage 1, SW2 = Stage 2, etc. For sound selection of each stage see the Sound Selection table on page 22.

1st Stage

2nd Stage

8th Stage

1st STAGE 2nd STAGE

michael ryan
LOGO
Page 24: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Controlled document No. D7490-01-01 (CN100047)\\My Documents\ SALES DATA\DATA SHEET\ Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com C l i f f o r d & S n e l l

Wiring Diagrams

INPUT OUTPUT SUPPLY SUPPLY TO NEXT MODEL

SOUND SELECTION SWITCH VOLUME 4x2 WAY INPUT AND OPEN=0, CLOSE=1 CONTROL OUTPUT TERMINALS

DC INPUT - 2nd STAGE WITH THIRD WIRE DC INPUT - 2nd STAGE BY SUPPLY REVERSAL

AC INPUT MODELS YL4 - YL5 - YL8

SOUNDERS MODELS YO3 - YO4 - YO5

INTRINSICALLY SAFE SOUNDERS MODELS YO3 - YO4 - YO5

INTRINSICALLY SAFE LED’STATUS’ AND ‘FLASHING’ BEACONS MODELS V4 IS

INDUSTRIAL AUDIBLE AND VISUAL ALARMS YODALARM AND YODALIGHT MODELS YO8/YL8 - YO8/YL8 SUPER

AC INPUT

DC INPUT

COMBINATION UNITS

michael ryan
LOGO
Page 25: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Controlled document No. D7492-01-01 (CN100047)\\My Docoments\ SALES DATA\DATA SHEET\ Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com C l i f f o r d & S n e l l

Wiring Diagrams

KS (KEYSWITCH) - MA (MAINS ADAPTER) - DH (DOOR HOLDER)

QUADALARM - FACE PLATE - ELECTRONIC

TYPE LC - ELECTRONIC SOUNDER

ABCD

0V +ve

A

1000Hz

B C D

1

2

3

4

800Hz

1000Hz

1000Hz

470Hz

430Hz

0.5S

0.5S

1S

Terminal 1

LINK IN

Terminal 2

Sound

+

Cont

--

-- +

Alt

Terminal 1

LINK OUT

Terminal 2

Sound

+

Cont

--

-- +

Off

1 2

TB1

Continuous tone (800Hz) Positive Vdc to Terminal 1 Negative Vdc to Terminal 2 Alternate tones (800 / 1000Hz) Reverse polarity

Connect DC or AC supply to the terminals as labelled. Earth continuity of cable sheath or conduit is maintained by fitting earth tags to the entry fittings and linking them together inside the back box. On AC units the earth wire MUST be connected to terminal marked

AUDIBLE AND VISUAL ALARM– MODEL YL2

DC INPUT– SEPARATE CONTROL OF SOUNDER AND STROBE. DC INPUT - COMMON CONTROL OF SOUNDER AND STROBE

FOR COMBINED SOUNDER AND STROBE FIT WIRE LINK JOINING TERMINALS 3 AND 5.

Sound Signal selection is made by setting of the PCB mounted switches. For switch settings see the Tone Table on page 24.

michael ryan
LOGO
Page 26: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Controlled document No. D8157-01-01 (CN100301)\\My Docoments\ SALES DATA\DATA SHEETS\ Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

For other options and full operating and installation instructions see website www.cliffordandsnell.com

Tom Cribb Road, Thamesmead, London SE28 0BH

Tel: +44 (0)20 8316 4477 or (0)20 8317 1717 Fax: +44 (0)20 8317 2400

Email: [email protected] Web Site: www.cliffordandsnell.com C l i f f o r d & S n e l l

Wiring Diagrams

TYPICAL CONNECTION DIAGRAMS FOR YODALEX STANDARD TEMP. EXPLOSION PROOF SOUNDER

MODEL YO9

A

MODELS: - BREAK GLASS, PUSH BUTTON

12

12

12

LIVE

NEU

TRAL

CO

NTR

OL

SOUND SELECTIONON ON

SW 1 SW 21 2 3 4 5 1 2 3 4 5

PRESSURE UNITCONNECTOR

LIVE

NEUTRAL

SOUNDER2ND STAGE

CONTROL PANEL

SOUND SELECTIONON ON

SW 1 SW 21 2 3 4 5 1 2 3 4 5

PRESSURE UNITCONNECTOR

1 2 3 4 TB1

1 2 3 4 TB

2

X

Y

SOUNDER+24vdc 0v

TO NEXT SOUNDER

SOUND SELECTIONON ON

SW 1 SW 21 2 3 4 5 1 2 3 4 5

PRESSURE UNITCONNECTOR

1 2 3 4 TB1

1 2 3 4 TB

2

TO NEXT SOUNDER

+24vdc 0v (stage 1)

0v +24vdc (stage 2)

A. Two stage alarm by third core Line monitoring by supply reversal Select alarm stage 1 on SW1 Select alarm stage 2 on SW2

B. Two stage alarm by supply reversal

Line monitoring by threshold method (<1v) Select alarm stage 1 on SW1 Select alarm stage 2 on SW2 Strobe operated from separate supply

1

2

3

4

5

6

7

MONITORING RESISTOR

END OF LINE DEVICE

IN

IN

OUT

OUT

1

2

3

4

5

6

7

1

2

3

4

5

6

7

1

2

3

4

5

6

7

IN

IN

OUT

END OF LINE DEVICE

IN

OUT

A B

When supplied without the monitoring resistor the Call Point should be connected as shown in 'A' or 'B' above.

The Call Point is supplied in two versions: - supplied with or without a monitoring resistor. The version with the monitoring resistor should be connected as shown above. Check panel instructions to ensure the correct value resistor is fitted.

If not required, remove and connect as shown in 'A' or 'B'

Ratings: - Vac: 250V max. / 12 V min. Imax: 5A resistive. Vdc: 30V max. / 12V min. Contact resistance: 50 millioms max. Conductor size: 2.5 sq.mm max. per terminal.

NORMALLY OPEN WITHSERIES MONITORING

INTERNAL SWITCHCONNECTIONS ARMED

NORMALLYOPEN

NORMALLY CLOSED

TYPICAL CONNECTION DIAGRAMS FOR MANUAL CALL POINTS

AC ALARM CONNECTIONS AND SOUND SIGNAL SELECTION

DC ALARM CONNECTION AND SOUND SIGNAL SELECTION

michael ryan
LOGO
Page 27: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

FREQUENCY

SOUND DIL SWITCH 12345 (ON = 1)

REP RATE (SEC)

SPECIAL APPLICATION

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Alternate two-tone Alternate two-tone Alternate fast two-tone Alternate fast two-tone Alternate two-tone Alternate two-tone Alternate v.fast two-tone Alternate v.fast two-tone Alternate two-tone Continuous note Continuous note Continuous note Continuous note Continuous note Interrupted tone Interrupted tone Interrupted tone Interrupted tone Interrupted tone Interrupted tone Interrupted tone Interrupted tone Interrupted tone Interrupted tone Int, fast, rising volume Fast siren Rising constant, fall ISO 8201 Evacuation Fast whoop Slow whoop Reverse sweep Siren

800-1000 2500-3100 800-1000 2500-3100 440-554 430-470 800-1000 2500-3200 440-554 700 1000 1000 2300 440 1000 420 1000 2500 2500 700 1000 700 700 720 1400 250-1200 1000 800-1000 500-1000 500-1200 1200-500 500-1200

11111 01111 10111 00111 11011 01011 10011 00011 11101 01101 10101 00101 11001 01001 10001 00001 11110 01110 10110 00110 11010 01010 10010 00010 11100 01100 10100 00100 11000 01000 10000 00000

0.5 0.5 0.25 0.25 0.4/0.1 1.0 0.13 0.07 2.0 - - - - - 2.0 1.25 0.5 0.25 0.5 6/12 1.0 4.0 0.25 0.7/0.3 0.25 0.085 10/40/10 As std 0.15 4.5 1.0 3.0

Fire alarms - Level crossing Security alarms Increased urgency - Level crossing Security deterrent AFNOR, France - - - Turn out, Sweden All-clear, Sweden - - - - - AS2220, Australia - - - Pre-vitalmessage, Sweden - Air-raid alarm, Sweden Local warning, Sweden Industrial alarm, Germany - - Industrial alarm, Germany Int’l evacuation alarm - Evacuation, The Netherlands Evacuation, Germany -

Tone Table

Controlled document No. D7493-01-02 (CN100301)\\My Documents\SALES DATA\DATA SHEETS\ Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

Page 28: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

FREQUENCY

SOUND DIL SWITCH 12345 (ON=1)

REP RATE (SEC)

SPECIAL APPLICATION

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Alternate two-tone Alternate two-tone Alternate fast two-tone Alternate fast two-tone Alternate two-tone Alternate two-tone Alternate v.fast two-tone Alternate v.fast two-tone Alternate two-tone Continuous note Continuous note Continuous note Continuous note Continuous note Interrupted tone Interrupted tone Interrupted tone Interrupted tone Interrupted tone Interrupted tone Interrupted tone Interrupted tone Interrupted tone Interrupted tone Int, fast, rising volume Fast siren Rising constant, fall ISO 8201 Evacuation Fast whoop Slow whoop Reverse sweep Siren

800-1000 2500-3100 800-1000 2500-3100 440-554 430-470 800-1000 2500-3200 440-554 700 1000 1000 2300 440 1000 420 1000 2500 2500 700 1000 700 700 720 1400 250-1200 1000 800-1000 500-1000 500-1200 1200-500 500-1200

00000 10000 01000 11000 00100 10100 01100 11100 00010 10010 01010 11010 00110 10110 01110 11110 00001 10001 01001 11001 00101 10101 01101 11101 00011 10011 01011 11011 00111 10111 01111 11111

0.5 0.5 0.25 0.25 0.4/0.1 1.0 0.13 0.07 2.0 - - - - - 2.0 1.25 0.5 0.25 0.5 6/12 1.0 4.0 0.25 0.7/0.3 0.25 0.085 10/40/10 As std 0.15 4.5 1.0 3.0

Fire alarms - Level crossing Security alarms Increased urgency - Level crossing Security deterrent AFNOR, France - - - Turn out, Sweden All-clear, Sweden - - - - - AS2220, Australia - - - Pre-vitalmessage, Sweden - Air-raid alarm, Sweden Local warning, Sweden Industrial alarm, Germany - - Industrial alarm, Germany Int’l evacuation alarm - Evacuation, The Netherlands Evacuation, Germany -

Tone Table

Controlled document No. D8115-01-02 (CN100301)\\My Documents\SALES DATA\data sheets\ Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation

NOTE: THIS TABLE IS FOR USE WITH MULTI–STAGE SOUNDERS ONLY MODELS YO4 - YO5 - YO8

Page 29: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Zone 0 (Gases) Zone 20 (Dust) Zone 1 (Gases) Zone 21 (Dust) Zone 2 (Gases) Zone 22 (Dust)

Where an ignitable mixture can exist for long periods of time under normal operating conditions Where an ignitable mixture can exist some of the time under normal operating condition Where an ignitable mixture is not likely to exist under normal operating conditions

450 T1 T1 300 T2 T2 280 T2 T2A 260 T2 T2B 230 T2 T2C 215 T2 T2D 200 T3 T3 180 T3 T3A 165 T3 T3B 160 T3 T3C 135 T4 T4 120 T4 T4A 100 T5 T5 85 T6 T6

0 Non Protected 1 Protected against objects greater

that 50mm 2 Protected against objects greater

that 12.5mm 3 Protected against objects greater

that 2.5mm 4 Protected against objects greater

that 1.0mm 5 Dust Protected 6 Dust Tight

0 Non Protected 1 Protected against vertical drip-

ping water 2 Protected against dripping

water when tilted at 15 degrees 3 Protected against spraying

water 4 Protected against splashing

water 5 Protected against water jets 6 Protected against powerfully

water jets 7 Protected against temporary

immersion 15cm to 1m 8 Protected against continuous

immersion

1st Digit protection against solid objects 2nd Digit protection against moisture

North American X-Ref Guide NEMA 3 similar to IP54 NEMA 4 similar to IP55 NEMA 4X similar to IP56 NEMA 6 similar to IP67

INGRESS PROTECTION IP XX

TEMPERATURE CLASSIFICATION

TEMPERATURES CLASSIFICATION

In Degrees C IEC NORTH AMERICA

NORTH AMERICAN CLASSIFICATION EUROPEAN & IEC CLASSIFICATION

Flammable Gases, Vapours or Liquids

Combustible Dust Ignitable Fibers

Class l Class ll Class lll

Div 1

Div 2

Clifford & Snell a division of Signature Industires Ltd part of the Digital Angel Corporation Controlled document No. D7494-01-01 (CN100047)\\My Documents\ SALES DATA\DATA SHEETS\

Page 30: Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons

Clifford & Snell

UK Office Tom Cribb Road Thamesmead London UK SE28 0BH

Tel: +44 (0) 208 317 1717 +44 (0) 208 316 4477 Fax: +44 (0) 208 317 2400 Email: [email protected]

Web: www.cliffordandsnell.com

German Office Ostheimer Strasse 16, D-63452 Hanau/Frankfurt, Germany

Tel: +49 61 81 9 06 65 40 Fax: +49 61 81 9 06 65 20 Email: [email protected], [email protected]

Web: www.cliffordandsnell.com

USA Office 9750 Whithorn Drive, Houston , Texas 77095, USA

Tel: +1 281 859 5300 Fax: +1 281 859 5317 Email: [email protected]

Web: www.cliffordandsnell.com

michael ryan
MR STAMP 2