Client:
Project: Tower 03-07 Sweet Gas Plant
Location:
Contract Number:
Inquiry Number:
PO Number:
Equipment Service:
Item Tag(s):
CENTRIFUGAL PUMP
DATA SHEET
Encana Corporation
Dawson Creek, BC, Canada
A6UE-4-0607-03-07-RQ-01
A6UE
Produced Water Disposal Pumps
TOW0307-P-9104A/B/C
Sheet:Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees Fluor Form Numberto return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished. 000.256.DS4601
Rev Date Description
Approved
10Of1
Document Number: TOW0307-C-070-EDS-P-9104
A 5-Mar-15 Issued for Review SG HL RK DSB 20-Mar-15 Issued for Quotation HL RC RK DS
By CheckedProcess Checked
TOW0307-PM-9104A/B/C
REV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
COOLING WATER: Not AvailableLOCATION:
UNDER ROOFHEATEDINDOOR
MOUNTED AT: TROPICALIZATION REQ'D TEMP
DIFFERENTIAL HEAD: m
m
KW
SITE AND UTILITY DATA
°C MAX
DESIGNRETURNINLET
m³/h
kPa g
kPa g
kPa
50.0
10329
10324.0
6.47 (Note 2)
FLOW:
DISCHARGE PRESS: (6.3.2)
HYDRAULIC POWER:
NPSHA:
DIFFERENTIAL PRESS.:
MINIMUM
VAPOR PRESSURE:
1.300 0.797
kPa(a)
945.1
-4.8
143.5 (Note 3)
NORMAL PARTICULATE SIZE (DIA. IN MICRONS):
CHLORIDE CONCENTRATION (ppm):
H2S CONCENTRATION (ppm): (6.12.1.12)
kJ/kgºC
1132 1114
4.318
PARTICULATE CONCENTRATION (ppm):
CORROSION DUE TO: (6.12.1.19)RELATIVE DENSITY:
VISCOSITY:
Max & Min values refer only to the property listed
Pa s
4.313
1.264.24
LIQUID TYPE OR NAME:
SPECIFIC HEAT:
Produced Water Produced Water
UNITS NOTEMINIMUMMAXIMUM SERVICE : INTERMITTENT
Proposal
NO. REQ'D :
Site: Dawson Creek, BC, Canada
Encana Corporation
Inquiry No.:
Item tag(s):
Tower 03-07 Sweet Gas Plant
MANUFACTURER: MODEL:
10
A6UE-4-0607-03-07-RQ-01
CLIENT:
3 PUMP SIZE :
SERVICE: Produced Water Disposal Pumps PLANT: Tower 03-07 Sweet Gas Plant
SERIAL NO.:
of
NO. STAGES :
CENTRIFUGAL PUMP
DATA SHEET
Note: This data sheet has been modified for that in Annex N of API 610, 11th Edition. (Note 1)
B Date: 20-Mar-15
Contract:
TOW0307-P-9104A/B/C
Revision:
A6UE
P.O. No.:
Unit:
Sheet 2
TYPE:
PARALLEL
DRIVER: TOW0307-PM-9104A/B/C APPLICABLE TO :
EROSION DUE TO: (6.12.1.19)
MAXIMUM
°C
C.L. IMPELLER
30.0
LIQUID CHARACTERISTICS
(Note 4)
SUCTION PRESSURE:
NPSHa Datum
PUMPING TEMP.:
UNITS
OPERATING CONDITIONS
RATED
*IF INTERMITTENT NO. OF STARTS / DAY
PUMPS OPERATE IN:
28 ELECTRICAL AREA CLASSIFICATION:
29
30 COOLING WATER CHLORIDE CONCENTRATION:
31 ELEVATION (MSL):
32 / INSTRUMENT AIR:
33 /
34
35
36
37
38
39
40
41
42
43
44
45 The required horsepower was calculated using the density of produced water (1114kg/m3) and the differential head at rated flow
46 The Produced Water chloride level is 142000 ppmw. Produced Water also contains 12 ppmw O2.
47
48
49
50
51
52
53
54
55
56
57
58
59
60
CLASS:
NPSH Available is based on pump suction and discharge nozzle centerline at 1750mm above grade and includes 1m safety margin.
Non API pump is required for the service even with API pump template being used.
2
1
NOTES
HERTZ
MIN
kPa g
MAXTEMP °C
575 208/120 120 MAX
HEATINGDRIVERS
VOLTAGE
3
MIN
PHASE
60 60 60
3
4
1 1
TEMP ID:ZONE: SOURCE
PRESSURE MINUNCLASSIFIED
kPa gMAX: 730
UTILITY CONDITIONS:
-40
Normal Press: 690 kPag @ 27 deg C normal, 35 deg C max.
HEATINGDRIVERS
SITE DATA:
795.6 m BAROMETER: 92 kPa a
STEAM: Not Available
PRESS.
UNUSUAL CONDITIONS:
ELECTRICITY: SHUTDOWNCONTROL
%
°C kPa g MIN: 414
RELATIVE HUMIDITY: MIN / MAX
RANGE OF AMBIENT TEMPS: MIN / MAX 35
kPa g
ppm
to return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished.Document Number
TOW0307-C-070-EDS-P-9104Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees
REV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15 /
16 /
17
18
19
20
21
22
23
24
25
26
27
CENTRIFUGAL PUMP
DATA SHEET
Note: This data sheet has been modified for that in Annex N of API 610, 11th Edition. (Note 1)
CASING TYPE: (6.3.10)
°C
CASE PRESSURE RATING:
CASING MOUNTING:
OH3 BACKPULLOUT LIFTING DEVICE REQ'D (9.1.2.6)
@MAWP: (6.3.6) kPa g
TOW0307-P-070-DSX-PM-9104
BEARING TYPE:
RADIAL:
THRUST:
STARTING METHOD:
SEE DRIVER DATA SHEET:
CONSTRUCTION
EST. MAX SOUND POWER LEVEL (dBA)
MAX. SOUND POWER LEVEL REQ'D (6.1.14) (dBA)
85 (dBA)
SUCTION SPECIFIC SPEED LIMIT: gpm,rpm,ft
SUCTION SPECIFIC SPEED: m³/s,rpm,m
11,000
HORIZONTAL
FRAME OR MODEL:
ORIENTATION:
LUBE:
PREFERRED OPERATING REGION: (6.1.11)
ALLOWABLE OPERATING REGION:
STABLE :THERMAL :
to
KW
MANUFACTURER:
NAMEPLATE POWER:
NOMINAL RPM:
RATED LOAD RPM:
m³/s
900 ENDSUCTION
m
SPECIFIC SPEED: (6.1.9) m³/s,rpm,m
NOZZLE CONNECTIONS: (6.5.5)
SIZE FACING RATING POSITION
EST. MAX SOUND PRESS. LEVEL
OTHER:
m³/s
RATED CURVE BEP FLOW (at rated impeller dia.)
IMPELLER DIA.: RATED: MAX:
EFFICIENCY:
MIN:
m³/s
KW
YES
SOURCE OF VARIABLE SPEED: MOTOR%
mm
API PUMP TYPE:
MAX. HEAD @ RATED IMPELLER:
mt
BB4 [Based on API 610 Definitions]
MIN. FLOW
to
m³/s
(dBA)
MAX. ALLOW. SOUND PRESS. LEVEL REQ'D (6.1.14)
m³/s
m
KW
m
m CL PUMP TO U/S BASEPLATE:
NPSHR at RATED FLOW :
NPSHR MARGIN at RATED FLOW :
10
DRIVER TYPE:RPM INDUCTION MOTOR
NO
VARIABLE SPEED REQUIRED:
RATED POWER:
A6UE
P.O. No.:
Unit:
Sheet
Contract:
TOW0307-P-9104A/B/C
Tower 03-07 Sweet Gas Plant
of
Item tag(s):
Revision:
A6UE-4-0607-03-07-RQ-01Inquiry No.:
B Date: 20-Mar-15
3
DRIVER (7.1.5)PERFORMANCE
PROPOSAL CURVE NO.:
GEAR:As Tested Curve No.:
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
couplings shall be balanced to ISO 1940-1 balance quality grade 2.5.
NOTES
5 All casing connections shall be braced with gussets in two orthogonal planes.
6 Drive train components, including but not limited to impeller, pump rotor, motor rotor, shall be dynamically balanced to ISO 1940 G1.0. Transmission units of
WINDOW ON COUPLING GUARD
COUPLING IN COMPLIANCE WITH (7.2.4)
COUPLING GUARD STANDARD PER (7.2.13.a) Non-Sparking
COUPLING WITH PROPRIETARY CLAMPING DEVICE (7.2.11)
COUPLING BALANCED TO ISO 1940-1 G6.3 (7.2.3)
COUPLING WITH HYDRAULIC FIT (7.2.10) NO
Note 6
mm
1.5 Min.
NORIGID
SPACER LENGTH
SERVICE FACTOR
MODEL:
RATING (POWER/100 RPM)
COUPLING: (7.2.3) (7.2.13.F)
MANUFACTURER:
SHRINK FIT LIMITED MOVEMENT IMPELLERS (9.2.2.3)
Note 6
ROTOR:
SHAFT FLEXIBILITY INDEX (SFI) (9.1.1.3)
- PROVIDE SOLEPLATE FOR OH 3/4/5 PUMPS:
- BOLT OH 3/4/5 PUMP TO PAD / FOUNDATION:
- IMPELLERS INDIVIDUALLY SECURED:
HYDROTEST OH PUMP AS ASSEMBLY
SUCTION PRESS. REGIONS DESIGNED FOR MAWP
ROTATION: (VIEWED FROM COUPLING END)
YES
HYDROTEST: °C@
VENT VALVE SUPPLIED BY
DRAIN VALVE SUPPLIED BY
DRAINS MANIFOLDED
DRAIN TO SKID EDGE
YES
SUPPLIER
PRESSURE CASING AUX. CONNECTIONS: (6.4.3.2)
GUSSET SUPPORT REQUIRED Note 5
MACHINED AND STUDDED CONNECTIONS (6.4.3.12)
VS 6 DRAIN
First Critical Speed Wet (Multi stage pumps only)
COMPONENT BALANCE TO ISO 1940 G1.0
kPa g
VENTS MANIFOLDED
THREADED CONS FOR PIPELINE SERVICE & < 50°C (6.4.3.2)
SPECIAL FITTINGS FOR TRANSITIONING (6.4.3.3)
CYLINDRICAL THREADS REQUIRED (6.4.3.8)
YES
RF
WARM-UP LINE
NO. SIZE TYPE
DRAIN
VENT
PRESSURE GAGE
TEMP GAGE
BALANCE/LEAK OFF
DISCHARGE 900 TOP
to return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished.Document Number
TOW0307-C-070-EDS-P-9104Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees
FACING RATING POSITION
REV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18 7. All pumps and drivers shall be provided with flats in two planes to permit
19 the use of hand held vibration monitoring equipment.
20
21
22
23
24
25 LOCATION OF PRESSURIZED LUBE OIL SYSTEM MOUNTED ON BASEPLATE:
26
27
PROVIDE SPACER PLATE UNDER ALL EQUIPMENT FEET
OTHER:
engineering notes.
Please refer to specific baseplate requirements in the requisition
YES
NOTES
CENTRIFUGAL PUMP
DATA SHEET
Note: This data sheet has been modified for that in Annex N of API 610, 11th Edition. (Note 1)
INTERCONNECTING PIPING PROVIDED BY: SUPPLIER
8. API D2 Super Duplex SS (A 890 grade 5A or 6A) shall be quoted as an option.
ISO 10438 DATA SHEETS ATTACHED
REVIEW AND APPROVE THRUST BEARING SIZE: (9.2.5.2.4)
LUBRICATION: (6.10.2.2) (6.11.3) (9.6.1) Oil Lubricated
/
/
PRESSURIZED LUBE OIL SYSTEM MTD. ON PUMP BASEPLATE
PRESSURE LUBE SYSTEM TO ISO 10438- (9.2.6.5)
THRUST
RADIAL
BEARINGS AND LUBRICATION (6.10.1.1)
BEARING (TYPE / NUMBER): (6.11.4)
BOWL (IF VS TYPE):
AISI 4140
IMPELLER WEAR RING:
IMPELLER:
CASE WEAR RING:
12% Cr
-29 °C
INSPECTION CLASS:
YES
YES
- GROUT VENT HOLES
- DRAIN CONNECTION
SUPPLIED WITH:
MOUNTING PADS SIZED FOR BASEPLATES LEVELING (7.3.5)
ENTIRE BASEPLATE DRAIN RIM
MOUNTING: BOLTED ON STEEL WORK
NON-GROUT CONSTRUCTION: (7.3.13) REQUIRED
VERTICAL LEVELING SCREWS: REQUIRED
LONGITUDINAL DRIVER POSITIONING SCREWS: REQUIRED
YES
MOUNTING PADS TO BE MACHINED (7.3.6)
A6UE
P.O. No.:
Unit:
Sheet 4 10
Tower 03-07 Sweet Gas Plant
Item tag(s):
of
Revision:
TOW0307-P-9104A/B/C
Contract:
Inquiry No.: A6UE-4-0607-03-07-RQ-01
B Date: 20-Mar-15
CONSTRUCTION (CONT'D)
12% Cr
MATERIAL (6.12.1.1)
REDUCED HARDNESS MATERIALS REQ'D (6.12.1.12.1)
CS + Internal Coating
BASEPLATE
API BASEPLATE NUMBER:
SHAFT:
FULL TOP DECKINGBASEPLATE CONSTRUCTION (7.3.14)
BASEPLATE DRAINAGE (7.3.1)
APPENDIX H CLASS: S-6: CS / 12% Cr (Note 8)
MINIMUM DESIGN METAL TEMP (6.12.4.1)
DIFFUSERS:
CASE:
BARREL:
APPLICABLE HARDNESS STANDARD (6.12.1.12.3)
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
MANIFOLD PIPING FOR PURCHASER CONNECTION (7.5.1.6)
VENT
DRAIN
COOLING WATER
TAG ALL ORIFICES (7.5.2.4)
m³/s
PIPING & APPURTENANCES
OTHER:
HEATING PIPING:
COOLING REQ'D
FITTINGS
COOLING WATER PIPING MATERIALS
COOLING WATER REQUIREMENTS:
BEARING HOUSING:
HEAT EXCHANGER:
NO
ADDITIONAL CENTRAL FLUSH PORT (6.8.9)
SEE ATTACHED ISO 21049/API 682 DATA SHEET YES
MECHANICAL SEAL (6.8.1)
INTERCONNECTING PIPING BY: SUPPLIER
SEAL SUPPORT SYSTEM MOUNTING
SEAL SUPPORT MOUNTED ON PUMP BASEPLATE (7.5.1.4):
IDENTIFY LOCATION ON BASEPLATE:
YES
Remarks
SOCKET WELD CONN ON SEAL GLAND (7.5.2.8)
N/A
YES
YES
HEATING MEDIUM
TOTAL COOLING WATER: m³/s
m³/s
HEATING AND COOLING (6.1.17)
COOLING WATER PIPING PLAN
COOLING WATER PIPING
N/AHEATING JACKET REQ'D (6.8.11)
PRESSURE GAGE TYPE:
TEMP GAGES (WITH THERMOWELLS) (9.1.3.6) NO
NUMBER PER THRUST BEARING INACTIVE SIDE
°C
NUMBER PER THRUST BEARING ACTIVE SIDE
NUMBER PER RADIAL BEARING
THRUST BEARING TEMP.:
PROVISION FOR VIB. PROBES NO
TEMPERATURE (7.4.2.3)
RADIAL BEARING TEMP.: °C
MONITORS AND CABLES SUPPLIED BY (7.4.2.4)
NUMBER PER RADIAL BEARING
NUMBER PER AXIAL BEARING
VIBRATION PROBES (7.4.2.2)
PROVISION FOR VIB. PROBES NO
NUMBER OF ACCELEROMETERS Note 7
MOUNTING LOCATION OF ACCELEROMETERS
MOUNTING LOCATION OF ACCELEROMETERS
FLAT SURFACE REQUIRED (6.10.2.11) YES
NUMBER OF ACCELEROMETERS
PROVISION FOR MTG ONLY (6.10.2.10) NO
INSTRUMENTATION
MOUNTING LOCATION OF ACCELEROMETERS
NOSEE ATTACHED API-670 DATA SHEET
ACCELEROMETER (7.4.2.1)
NUMBER OF ACCELEROMETERS
CONSTANT LEVEL OILER: REQUIRED (TRICO)
OIL VISC. ISO GRADE
to return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished.Document Number
TOW0307-C-070-EDS-P-9104Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees
REV
1
2
3
4 SPECIFICATION NUMBER:
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
CENTRIFUGAL PUMP
DATA SHEET
Note: This data sheet has been modified for that in Annex N of API 610, 11th Edition. (Note 1)
RESIDUAL BALANCE TEST (J.4.1.2)
YESNOTIFICATION OF SUCCESSFUL SHOP PER. TEST (8.1.1.c)(8.3.3.5)
PMI TESTING REQUIRED (8.2.2.8)
COMPONENTS TO BE TESTED:
FOR
METHOD
HARDNESS TEST REQUIRED (8.2.2.7)
ADDITIONAL SUBSURFACE EXAMINATION (6.12.1.5)(8.2.1.3)
NO
NO
LIQUID PENETRANT YES
ULTRASONIC
MAG PARTICLE YES
RADIOGRAPHY
YES
INSPECTION REQUIRED FOR CASTINGS
YESCASTING REPAIR WELD PROCEDURE APPR. REQ'D (6.12.2.5)(6.12.3.1)
(6.12.3.4.e) MAG PARTICLE
INSPECTION REQUIRED FOR CONNECTION WELDS (6.12.3.4.d)
YES
YES
YES
OTHER
SHOP INSPECTION (8.1.1)
PERFORMANCE CURVE & DATA APPROVAL PRIOR TO SHIPMENT
TEST WITH SUBSTITUTE SEAL (8.3.3.2.b)
IMPELLER
CASING
SHAFT
YES
YES
NO
YESMATERIAL CERTIFICATION REQUIRED:
Note 9 (6.12.1.8)
RADIOGRAPHY
LIQUID PENETRANT
ULTRASONIC
N2 PURGE (9.2.8.4)
DRIVERPUMP
FINISH COAT:
DETAILS OF LIFTING DEVICES:
SHIPMENT: (8.4.1) EXPORT
FINISH COAT:
START-UP YES
NORMAL MAINTENANCE
WEIGHTS kg
SPARE PARTS
ITEM No. TOTALBASEGEAR
PRIMER:
SHIPPING & STORAGE CONTAINER FOR VERT. STORAGE (9.2.8.3)
ROTOR STORAGE ORIENTATION (9.2.8.2)
SPARE ROTOR ASSEMBLY PACKAGED FOR:
YES
YESOUTDOOR STORAGE MORE THAN 6 MONTHS
EXPORT BOXING REQUIRED
Tower 03-07 Sweet Gas Plant
TESTSURFACE PREPARATION AND PAINT
PUMP SURFACE PREPARATION:
PRIMER:
YESSUPPLIER'S STANDARD
OTHER (SEE BELOW)
PUMP:
BASEPLATE:
BASEPLATE SURFACE PREPARATION:
A6UE
P.O. No.:
Unit:
Sheet
Contract:
TOW0307-P-9104A/B/C
5 10
A6UE-4-0607-03-07-RQ-01Inquiry No.:
Item tag(s):
of
Revision: B Date: 20-Mar-15
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60 REMOVE CASING AFTER TEST
PER ASME SECTION VIII
PER EN 13445IMPACT TEST (6.12.4.3)
OBSERVE
REMOVE / INSPECT HYDRODYNAMIC BRGS. AFTER TEST (9.2.7.5)
AUXILIARY EQUIPMENT TEST (8.3.4.6)
RETEST ON SEAL LEAKAGE (8.3.3.2.d)
RETEST REQUIRED AFTER FINAL HEAD ADJ. (8.3.3.7.b)
NPSH TESTING TO HI 1.6 OR ISO 9906 (8.3.4.3.3)
TEST NPSHA LIMITED TO 110% SITE NPSHA (8.3.3.6)
OBSERVE
NON-WIT
OBSERVE
4 HR. MECH RUN TEST (8.3.4.2.2)
BEARING HOUSING RESONANCE TEST (8.3.4.7)
SOUND LEVEL TEST (8.3.4.5)
CLEANLINESS PRIOR TO FINAL ASSEMBLY (8.2.2.6)
LOCATION OF CLEANLINESS INSPECTION
CHECK FOR CO-PLANAR MOUNTING PAD SURFACES
MECHANICAL RUN TEST UNTIL OIL TEMP STABLE
TEST DATA POINTS TO (8.3.3.3)
OBSERVE
OBSERVE
OBSERVENPSH (8.3.4.3.1)(8.3.4.3.4)
NPSH-1ST STAGE ONLY (8.3.4.3.2)
TEST TOLERANCES TO (8.3.3.4)
YESBASEPLATE TEST (7.3.21)
STRUCTURAL RESONANCE TEST (9.3.9.2)
NOZZLE LOAD TEST
4 HR. MECH RUN TEST AFTER OIL TEMP STABLE (8.3.4.2.1)
COMPLETE UNIT TEST (8.3.4.4.1)
LOCATION OF AUX. EQUIPMENT TEST
EQUIPMENT TO BE INCLUDE IN AUX TESTS
HYDROSTATIC
HYDROSTATIC TEST OF BOWLS & COLUMN (9.3.13.2)
PERFORMANCE TEST
TEST IN COMPLIANCE WITH (8.3.3.2)
CADMIUM PLATED BOLTS PROHIBITED
VENDOR TO KEEP REPAIR AND HT RCDS (8.2.1.1.C)
VENDOR TO SUBMIT TEST PROCEDURES (8.3.1.1)
SUBMIT INSPECTION CHECK LIST (8.1.5)
YES
YES
CONNECTION BOLTING (7.5.1.7)
YES
YES
FLANGES REQ'D INPLACE OF SKT WELD UNIONS (7.5.2.8)
INCLUDE PLOTTED VIBRATION SPECTRA (6.9.3.3)
YES
IGNITION HAZARD ASSMT TO EN 13463-1 (7.2.13.e)
CASING RETIREMENT THICKNESS DRAWING (10.3.2.3)
INSTALLATION LIST IN PROPOSAL (10.2.3.1)
VFD STEADY STATE DAMPED RESPONSE ANALYSIS (6.9.2.3)
TRANSIENT TORSIONAL RESPONSE (6.9.2.4)
BEARING LIFE CALCULATIONS REQUIRED (6.10.1.6)
ADDITIONAL DATA REQUIRING 20 YEARS RETENTION (8.2.1.1)
YES
CONNECTION DESIGN APPROVAL (9.2.1.4)
TORSIONAL ANALYSIS / REPORT (6.9.2.10)
PROGRESS REPORTS
OUTLINE OF PROC FOR OPTIONAL TESTS (10.2.5)
OPERATION TO TRIP SPEED
MAX DIA. IMPELLERS AND / OR NO. OF STAGES
YES
MAXIMUM DISCHARGE PRESSURE TO INCLUDE
COORDINATION MEETING REQUIRED (10.1.3)
MAX RELATIVE DENSITY
OTHER PURCHASER REQUIREMENTS
LATERAL ANALYSIS REQUIRED (9.1.3.4)(9.2.4.1.3)
Document NumberTOW0307-C-070-EDS-P-9104
Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agreesto return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished.
DYNAMIC BALANCE ROTOR (6.9.4.4) YES
MODAL ANALYSIS REQUIRED (9.3.9.2)
REV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
CENTRIFUGAL PUMP
DATA SHEET
Note: This data sheet has been modified for that in Annex N of API 610, 11th Edition. (Note 1)
ALTERNATIVE MATERIAL INSPECTIONS AND ACCEPTANCE CRITERIA (SEE TABLE 14 ) (8.2.2.5)
FOR CASTINGSFOR FABRICATIONS
VISUAL INSPECTION (ALL SURFACES)
TYPE OF INSPECTION
RADIOGRAPHY
ULTRASONIC INSPECTION
MAGNETIC PARTICLE INSPECTION
LIQUID PENETRANT INSPECTION
METHOD
NON-PRESSURE RETAINING STRUCTURAL WELDING SUCH AS BASEPLATES OR SUPPORTS
THESE REFERENCES MUST BE LISTED BY THE PURCHASER DEFAULT TO TABLE 15
MATERIAL INSPECTION
MAGNETIC PARTICLE OR LIQUID PENETRANT EXAMINATION OF PLATE EDGES
POSTWELD HEAT TREATMENT
POSTWELD HEAT TREATMENT OF CASING FABRICATION WELDS
A6UE
Tower 03-07 Sweet Gas Plant
Item tag(s):
Contract:
Unit:
Sheet 6
TOW0307-P-9104A/B/C
Revision:
P.O. No.:
B Date: 20-Mar-15
PRESSURE VESSEL DESIGN CODE REFERENCES
THESE REFERENCES MUST BE LISTED BY THE SUPPLIER:
CASTING FACTORS USED IN DESIGN (TABLE 3)
SOURCE OF MATERIAL PROPERTIES
A6UE-4-0607-03-07-RQ-01
10of
Inquiry No.:
WELDING AND REPAIRS (Please Refer to ECA-WELD-S01)
THESE REFERENCES MUST BE LISTED BY THE PURCHASER (DEFAULT TO TABLE 10 IF NO PURCHASER PREFERENCE IS STATED)
ALTERNATIVE WELDING CODES AND STANDARDS
WELDING REQUIREMENT (APPLICABLE CODE OR STANDARD)
WELDER/OPERATOR QUALIFICATION
WELDING PROCEDURE QUALIFICATION
28
29
30 Purchaser's authorized inspector shall verify the surface flatness and surface finish of the machined underside of the baseplates.
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
A516 Gr. 70N; Alloy Components: A352 - CA6NM
This activity shall be witnessed by Purchaser's inspector during final release inspection.
11 Auxiliary system materials shall be low temperature carbon steel where applicable, A333-6, A350 LF2 Cl1, A352 - LCB/LCC,
Material certificates shall be provided for casings, cover, impellers, shafts9
10
NOTES
to return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished.Document Number
TOW0307-C-070-EDS-P-9104Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees
REV
1
2 Pump and System Curves
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22 System Sketch
23
24
25
26
27
A6UE-4-0607-03-07-RQ-01
10of
Inquiry No.:
P.O. No.:
Sheet 7
CENTRIFUGAL PUMP
DATA SHEET
Note: This data sheet has been modified for that in Annex N of API 610, 11th Edition. (Note 1)
Item tag(s):
Contract:
Unit:
B
A6UE
TOW0307-P-9104A/B/C
Date: 20-Mar-15
Tower 03-07 Sweet Gas Plant
Revision:
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
TOW0307-C-070-EDS-P-9104Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agreesto return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished.
Document Number
REV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
B Date:
NBR vs
Other :
Other : or UNS S31635 Other :
or UNS N06455 UNS N10276
EPM / EPDM SS-SIC RB-SIC UNS N08020
Spiral Wound Gasket SIC vs SIC UNS N07718 (TypeC)
UNS S31600 UNS N08020
UNS N10276 (TypeB) UNS N10276 UNS S31600 / S31635FKM FFKM CARBON vs SIC
62
Gas
MATERIALS (REFERENCE 6.1.6 & ANNEX B)
SECONDARY SEALS SEAL FACES METAL BELLOWS SPRINGS METAL PARTS
74
SLEEVE-SHAFT DRIVE Set-Screw Onto Shaft Alternative (6.1.3.13) SPECIFY :
11 32 53C3NC-FB
02 14 53B
61 54
3CW-FF Tang. LBO Conn.
01 13 53A
31 52 7132 61 72
3 (3.4)
Ba
rrie
r Liquid 3CW-FB 3CW-BB FX
3NC-FF3NC-BB
75Tangential LBO Connection 02 14
23 41 62Dist. Flush 01 1376
2 (3.3)
Bu
ffer Liquid 2CW-CW FX
21
Gas 2CW-CS 2NC-CS FX 21Dist. Flush 11
1114 31 51
32 61
62Alternative Bush 02
13 23 501CW-FL Dist. Flush 011 (3.2) 1CW-FX
(CODE CW) Type C (3.74)
TYPE Type A (3.72) Type B (3.73) Alternate Stationary (Type A&B)
Single Spring (Type A)
ARR'GT Default Configuration Alternate Design Flush Plans (See Annex G)
Alternate Rotating (Type C)
By Manufacturer or Purchaser
Seal Specification - (Ref. 4.1, Figures 1 to 6)
CATEGORY Seal Category 1 Seal Category 2 Seal Category 3
NOTES: Information Below to be Completed : By Purchaser By Manufacturer
Seal Code (Annex D)
Inquiry No.: A6UE-4-0607-03-07-RQ-01
Sheet 8
MECHANICAL SEAL DATA SHEET
Contract: A6UE
Item No: TOW0307-P-9104A/B/C
Revision:
of 10
Client: Encana Corporation Vendor:
Service: Produced Water Disposal Pumps Plant: Tower 03-07 Sweet Gas Plant
No. Required: 3 Site: Dawson Creek, BC, Canada
20-Mar-15
Unit: Tower 03-07 Sweet Gas Plant
Note: This data sheet has been modified from that in the annex of API Standard 682, Third Edition.
P.O. No.:
28
29
30
31
32 /33
34
35
36
37
38
39
40
41
42
43
44
45
46 /
47
48
49
50
51
52
53
54
55
56
57
58
59
60
Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees Document Numberto return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished. TOW0307-C-070-EDS-P-9104
NOTES
14. Supplier to confirm the seal selection and arrangement
Shaft Speed : RPM
Shaft Rotation (Viewed From Driver) : CCW CW
kPa gMSSP (3.44) :
Suction Press. (Rated) : kPa g
Shaft Horizontal Vertical Diameter :
Seal Chamber Press. Normal : kPa g Min / Max MDSP :
Pump Operating Pressure Discharge Press. : kPa g
Size :
kPa g
Case Material :
Chamber Cooling
PUMP DATA - Refer to Sheet 2
Manufacturer : Model :
Floating Throat Bushing Fixed Throat Bushing Chamber Heating
Bolt-On Chamber (6.1.2.5) Seal Chamber Flush Port Req'd Seal Chamber Vent Req'd
Tapered ISO 3069-C Other :
SEAL CHAMBER DATA (REFERENCE 6.1.2.4)
ISO 13709 ASME B73.1&2 Cylindrical
Alternative Seal For Pump Performance Test Total Seal Axial Thrust on Shaft : N
kW
Modified Faces For Pump Performance Test Heat Soak at Normal Conditions : kW
Vendor's Seal Code : Generated Heat at Normal Conditions :
°C
Seal Drawing No. : Min. Design Metal Temperature (6.1.6.11.1): -29 °C
Size / Type : Maximum Allowable Temperature (3.40) :
Data Requirements Form (Annex J) Static Sealing Pressure Rating (3.69) : kPa g
MECHANICAL SEAL DATA
Seal Vendor : John Crane Dynamic Sealing Pressure Rating (3.19) : kPa g
REV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17 /
18 /
19 /
20 /
21
22
23
24
25 /
26 /
27
B Date:
cP
Fluid Temperature Specific Heat Capacity at Const. Press.: kJ/kgK
Atmospheric Boiling Point °C
Supply Pressure Max. / Min. : kpag Viscosity at Normal Pump Temperature :
kpaa Max. Temp : kpaa
Flow Rate Required Max. / Min. : m3/hr
Seal Vendor Review Purchaser Review Normal Temperature :
@ Max. Temp. :
Purchaser Selection Seal Vendor Selection Vapor Pressure at
m3/hr
BUFFER / BARRIER MEDIUM Specific Gravity:
Type or Name : @ Normal Temperature :
Type or Name : Flow Rate Required Max. / Min. :
kpaa
QUENCH MEDIUM (PLAN 51, 62) Supply Temperature Max. / Min. : ppm
m3/hr
Spec. Gravity at Temp Indct'd @ Norm Temp @ Max Temp Pressure Req'd Max / Min
Flow Rate Req'd Max / MinFluid Temp Min Norm Max
Type or Name : Conc'n : % kpaa
Seal Vendor Review Required Atmos. Boiling pt °C Visc. at Norm Pump Temp
@ Norm Temp kpaa @ Max Temp
cP
Alt. Process Fluids(incl. Commissioning) Specify
FLUSH FLUID (PLAN 32) If flush is pumpage, then flush data is not req'd Vapor Pressure
kpaa Regulation Level : ppmAtmos. Boiling pt Visc. At Norm Pump Temp
at Norm Temp: kpaa at Max Temp:
cP Special Pump Cleaning Procedures:
Vapor Pressure Pumped Stream is Regulated For Fugitive or Other Emissions
Pumped Stream Can Plate Out or Decompose :Spec. Gravity at Norm Temp: at Max Temp: Specify Conditions :
Norm °C Max °CSpecify Agents : @ Temp : °C
Pumping Temp. Min °C
Concentration : Mass Fraction
Solid Contaminant Pumped Stream Contains Agents That Polymerize
Other : @ ppmCl2 ppm
Flammable
°C
Solidifies: °C
Pumped Stream Solidifies Under Shear
Revision:
of 10
Dissolved Contaminant H2S ppm Wet
Type or Name : Concentration : % Fluid Solid at Ambient
Hazardous
FLUID DATA
PUMPED STREAM
Pour pt:
20-Mar-15
Unit: Tower 03-07 Sweet Gas Plant
Note: This data sheet has been modified from that in the annex of API Standard 682, Third Edition.
P.O. No.:
Inquiry No.: A6UE-4-0607-03-07-RQ-01
Sheet 9
MECHANICAL SEAL DATA SHEET
Contract: A6UE
Item No: TOW0307-P-9104A/B/C
28
29
30
31
32 /
33 /
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees Document Numberto return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished. TOW0307-C-070-EDS-P-9104
Closed
NOTES
Cooling Water Flow Rate : m3/hr
Sight Flow Indicators (8.4.3) Open
Tubing Galvanized Piping (8.4.2)
Equipment Reference / Code : High Flow Alarm Switch For Plan 75(8.6.5.3)Cooling Water Line Supplier : Test Connection (8.6.5.4)
Heat Exchanger Supplier : PLAN 75 and 76 SYSTEMWater Cooled Air Cooled ISO 15649 Equipment Supplier :
Thermal Relief Valves Required (9.8.3) Equipment Supplier :COOLING SYSTEM (PLAN 21,22,23,41,53B,53C) High Flow Alarm Switch (8.6.6.5)
Type and Spec. of Heat Tracing (8.6.5.8)
PLAN 72 and 74 SYSTEM
Utility Manifold Connections Required (8.4.4) Plan 32 Flow Indicator Plan 32 Temp. Indicator
Define : Cyclone Separator Supplier :
Special Cleaning and Decontamination Requirements Plan 32 Equipment Supplier :
Tubing Piping (8.5.2.2)
Special Requirements For Hazardous Service : Restriction Orifice Nipple in Flush Line (8.5.2.4)
Pipe Taper Threads (8.1.9) ISO 7 ASME B1.20.1
ACCESSORIES (Clauses 8 and 9)
GENERAL PLAN 11, 12, 13, 14, 21, 23, 31, 32 and 41 SYSTEMS
Joint User / Vendor Layout of Equipment (8.1.4) Connecting Line Supplier :
CAT
TCLASS
Design Ambient (Min. / Max.) : °C ATEX (Ex Directive 94/9/EC): GR
ppm
Area Classification CL. Zone.
Hz: Cooling Water Supply Temp °C
kpagDiv. Cooling Water Press. Norm/Design :
SITE AND UTILITIES
Control Voltage V : P :
Max. : °C Cooling / Heating RequiredMin. : °C Normal : °C
Cl2 :
Unclassified
REV
1
2
3
4
5
6 /
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
Date:
LEVEL INDICATORS (9.6)
Weld Pad External, Removable (9.6.2)
Flow Instruments (9.7) Transmitters (9.7.3)
Transmitters (9.5.3.2)
Hydrostatic Capacitance Ultrasonic
Pressure Switches (9.5.2) Transmitters (9.5.2.3) Level Switches (9.5.3)
User Specification Reference For Instrument / Controls :
MPSTD-A-000-GEN-00042-0000
PRESSURE GAUGES (9.4)
Oil Filled Pressure Gauges (9.4.3)
ASME Code Stamp Required
INSTRUMENTATION
Equipment Support Supplier : Test Based H / Q Curve For Internal Circulating Device
Filling System Supplier : External Circulating Pump (8.6.3.1)
psigTubing SCH. 80 Piping (8.5.4.4.9) High Level Alarm Required (8.5.4.2.i)
Rising Pressure (Arr 2) Set at : psigConnecting Line Supplier : Falling Pressure (Arr 3) Set at :
Primary Equipment Supplier : PRESSURE SWITCH (8.5.4.2.h) TO ACTIVATE ON :Supplier Reference / Code :
Alternative Fabrication Standard : Temperature Indicator (Plan 53B,53C)
psig
System Hold-Up Period (Plans 53B & 53C) : days
Dimensional Variations To Standard Figure G28 Set Pressure Range, Max. / Min.
A6UE
Item No:
Reservoir MAWP (3.4.1) psig
galDimensional Variations To Standard Figure G27 NLL to Gland Plate Height ft
Standard (Fig. G27) Alternative (Fig. G28) Reservoir Capacity (8.5.4.3) :
B
TOW0307-P-9104A/B/C
Revision:
of 10
ACCESSORIES (Clauses 8 and 9) CONT'D
PLAN 52 and 53 SYSTEMS EN 13445 or Other Code Applicable
20-Mar-15
Unit: Tower 03-07 Sweet Gas Plant
Note: This data sheet has been modified from that in the annex of API Standard 682, Third Edition.
P.O. No.:
Inquiry No.: A6UE-4-0607-03-07-RQ-01
Sheet 10
MECHANICAL SEAL DATA SHEET
Contract:
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees Document Numberto return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished. TOW0307-C-070-EDS-P-9104
NOTES
Hardness Test (10.2.3k) Required For : Alternate Seal Pump Test (10.3.5.2) See Page 2 Line 32
Purchaser Approval Req'd For Welded Optional Qualification Testing Required (10.3.1.1.2)
Connection Design (6.1.6.10.5) Mod. Faces For Pump Test (10.3.5.1) See Page 2 Line 31
Liquid Penetrant
Inspector's Check List (10.1.7 & Annex H) Radiographic Ultrasonic
Specify : Magnetic Particle
INSPECTION AND TESTING
Purchaser Participation in Inspection & Test 100% Inspection of All Welds (6.1.6.10.5) Using :
Client:
Project: Tower 03-07 Sweet Gas Plant
Location:
Contract Number:
Inquiry Number:
PO Number:
Equipment Service:
Item Tag(s):
CENTRIFUGAL PUMP
DATA SHEET
Encana Corporation
Dawson Creek, BC, Canada
A6UE-4-0607-03-07-RQ-01
A6UE
FRAC Water Supply Pumps
TOW0307-P-9105A/B/C
Sheet:
By CheckedProcess Checked
TOW0307-PM-9105A/B/C
A 05-Mar-15 Issued for Review SG HL RK DSB 20-Mar-15 Issued for Quotation HL RC RK DS
Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees Fluor Form Numberto return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished. 000.256.DS4601
Rev Date Description
Approved
10Of1
Document Number: TOW0307-C-070-EDS-P-9105
REV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
LIQUID CHARACTERISTICS
(Note 4)
SUCTION PRESSURE:
NPSHa Datum
PUMPING TEMP.:
UNITS
OPERATING CONDITIONS
RATED
*IF INTERMITTENT NO. OF STARTS / DAY
PUMPS OPERATE IN: PARALLEL
DRIVER: TOW0307-PM-9105A/B/C APPLICABLE TO :
EROSION DUE TO: (6.12.1.19)
MAXIMUM
°C
C.L. IMPELLER
30.0
SERIAL NO.:
of
NO. STAGES :
CENTRIFUGAL PUMP
DATA SHEET
Note: This data sheet has been modified for that in Annex N of API 610, 11th Edition. (Note 1)
B Date: 20-Mar-15
Contract:
TOW0307-P-9105A/B/C
Revision:
A6UE
P.O. No.:
Unit:
Sheet 2
TYPE:NO. REQ'D :
Site: Dawson Creek, BC, Canada
Encana Corporation
Inquiry No.:
Item tag(s):
Tower 03-07 Sweet Gas Plant
MANUFACTURER: MODEL:
10
A6UE-4-0607-03-07-RQ-01
CLIENT:
3 PUMP SIZE :
SERVICE: FRAC Water Supply Pumps PLANT: Tower 03-07 Sweet Gas Plant
UNITS NOTEMINIMUMMAXIMUM SERVICE : INTERMITTENT
Proposal
RELATIVE DENSITY:
VISCOSITY:
Max & Min values refer only to the property listed
Pa s
4.313
1.264.24
LIQUID TYPE OR NAME:
SPECIFIC HEAT:
Produced Water (Note 3)
10.0
NORMAL PARTICULATE SIZE (DIA. IN MICRONS):
CHLORIDE CONCENTRATION (ppm):
H2S CONCENTRATION (ppm): (6.12.1.12)
kJ/kgºC
1132 1114
4.318
PARTICULATE CONCENTRATION (ppm):
CORROSION DUE TO: (6.12.1.19)
FLOW:
DISCHARGE PRESS: (6.3.2)
HYDRAULIC POWER:
NPSHA:
DIFFERENTIAL PRESS.:
MINIMUM
VAPOR PRESSURE:
1.300 0.797
kPa(a)
444.0
0.76 -1.21
121.3 (Note 3)
INLET
m³/h
kPa g
kPa g
kPa
90.0
4851.0
6064 4850.0
6.9 (Note 2)
TEMP
DIFFERENTIAL HEAD: m
m
KW
SITE AND UTILITY DATA
°C MAX
DESIGNRETURN
COOLING WATER: Not AvailableLOCATION:
UNDER ROOFHEATEDINDOOR
MOUNTED AT: NOTE 4 TROPICALIZATION REQ'D
28 ELECTRICAL AREA CLASSIFICATION:
29
30 COOLING WATER CHLORIDE CONCENTRATION:
31 ELEVATION (MSL):
32 / INSTRUMENT AIR:
33 /
34
35
36
37
38
39
40
41
42
43
44
45 The required horsepower was calculated using the density of produced water (1114kg/m3) and the differential head at rated flow
46 The Produced Water chloride level is 142000 ppmw. Produced Water also contains 12 ppmw O2.
47
48
49
50
51
52
53
54
55
56
57
58
59
60
to return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished.Document Number
TOW0307-C-070-EDS-P-9105Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees
RELATIVE HUMIDITY: MIN / MAX
RANGE OF AMBIENT TEMPS: MIN / MAX 35
kPa g
ppmSITE DATA:
795.6 m BAROMETER: 92 kPa a
STEAM: Not Available
PRESS.
UNUSUAL CONDITIONS:
ELECTRICITY: SHUTDOWNCONTROL
%
°C kPa g MIN: 414 kPa gMAX: 730
UTILITY CONDITIONS:
-40
Normal Press: 690 kPag @ 27 deg C normal, 35 deg C max.
HEATINGDRIVERS
TEMP ID:ZONE: SOURCE
PRESSURE MINUNCLASSIFIED
PHASE
60 60 60
3
4
1 1
575 208/120 120 MAX
HEATINGDRIVERS
VOLTAGE
3
MIN
CLASS:
NPSH Available is based on pump suction and discharge nozzle centerline at 1750mm above grade and includes 1m safety margin.
Non API pump is required for the service even with API pump template being used.
2
1
NOTES
HERTZ
MIN
kPa g
MAXTEMP °C
REV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15 /
16 /
17
18
19
20
21
22
23
24
25
26
27
VARIABLE SPEED REQUIRED:
RATED POWER:
A6UE
P.O. No.:
Unit:
Sheet
Contract:
TOW0307-P-9105A/B/C
Tower 03-07 Sweet Gas Plant
of
Item tag(s):
Revision:
A6UE-4-0607-03-07-RQ-01Inquiry No.:
B Date: 20-Mar-15
3
DRIVER (7.1.5)PERFORMANCE
PROPOSAL CURVE NO.:
GEAR:As Tested Curve No.:
10
DRIVER TYPE:RPM INDUCTION MOTOR
NO
API PUMP TYPE:
MAX. HEAD @ RATED IMPELLER:
MAX. POWER @ RATED IMPELLER: (6.8.9)
BB4 [Based on API 610 Definitions]
MIN. FLOW
to
m³/s
(dBA)
MAX. ALLOW. SOUND PRESS. LEVEL REQ'D (6.1.14)
m³/s
m
KW
m
m CL PUMP TO U/S BASEPLATE:
NPSHR at RATED FLOW :
NPSHR MARGIN at RATED FLOW :
OTHER:
m³/s
RATED CURVE BEP FLOW (at rated impeller dia.)
IMPELLER DIA.: RATED: MAX:
EFFICIENCY:
MIN:
m³/s
KW
YES
SOURCE OF VARIABLE SPEED: MOTOR%
mm
m
SPECIFIC SPEED: (6.1.9) m³/s,rpm,m
NOZZLE CONNECTIONS: (6.5.5)
SIZE FACING RATING POSITION
EST. MAX SOUND PRESS. LEVEL
900 ENDSUCTION
PREFERRED OPERATING REGION: (6.1.11)
ALLOWABLE OPERATING REGION:
STABLE :THERMAL :
to
KW
MANUFACTURER:
NAMEPLATE POWER:
NOMINAL RPM:
RATED LOAD RPM:
m³/s
CONSTRUCTION
EST. MAX SOUND POWER LEVEL (dBA)
MAX. SOUND POWER LEVEL REQ'D (6.1.14) (dBA)
85 (dBA)
SUCTION SPECIFIC SPEED LIMIT: gpm,rpm,ft
SUCTION SPECIFIC SPEED: m³/s,rpm,m
11,000
HORIZONTAL
FRAME OR MODEL:
ORIENTATION:
LUBE:
TOW0307-P-070-DSX-PM-9105
BEARING TYPE:
RADIAL:
THRUST:
STARTING METHOD:
SEE DRIVER DATA SHEET:
CASING MOUNTING:
OH3 BACKPULLOUT LIFTING DEVICE REQ'D (9.1.2.6)
@MAWP: (6.3.6) kPa g
CASING TYPE: (6.3.10)
°C
CASE PRESSURE RATING:
CENTRIFUGAL PUMP
DATA SHEET
Note: This data sheet has been modified for that in Annex N of API 610, 11th Edition. (Note 1)
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
to return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished.Document Number
TOW0307-C-070-EDS-P-9105Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees
FACING RATING POSITION
DISCHARGE 900 TOP
WARM-UP LINE
NO. SIZE TYPE
DRAIN
VENT
PRESSURE GAGE
TEMP GAGE
BALANCE/LEAK OFF
RF
GUSSET SUPPORT REQUIRED Note 5
MACHINED AND STUDDED CONNECTIONS (6.4.3.12)
VS 6 DRAIN
First Critical Speed Wet (Multi stage pumps only)
COMPONENT BALANCE TO ISO 1940 G1.0
kPa g
VENTS MANIFOLDED
THREADED CONS FOR PIPELINE SERVICE & < 50°C (6.4.3.2)
SPECIAL FITTINGS FOR TRANSITIONING (6.4.3.3)
CYLINDRICAL THREADS REQUIRED (6.4.3.8)
YES
YES
HYDROTEST: °C@
VENT VALVE SUPPLIED BY
DRAIN VALVE SUPPLIED BY
DRAINS MANIFOLDED
DRAIN TO SKID EDGE
YES
SUPPLIER
PRESSURE CASING AUX. CONNECTIONS: (6.4.3.2)
- IMPELLERS INDIVIDUALLY SECURED:
HYDROTEST OH PUMP AS ASSEMBLY
SUCTION PRESS. REGIONS DESIGNED FOR MAWP
ROTATION: (VIEWED FROM COUPLING END)
Note 6
ROTOR:
SHAFT FLEXIBILITY INDEX (SFI) (9.1.1.3)
- PROVIDE SOLEPLATE FOR OH 3/4/5 PUMPS:
- BOLT OH 3/4/5 PUMP TO PAD / FOUNDATION:
MODEL:
RATING (POWER/100 RPM)
COUPLING: (7.2.3) (7.2.13.F)
MANUFACTURER:
SHRINK FIT LIMITED MOVEMENT IMPELLERS (9.2.2.3)
Non-Sparking
COUPLING WITH PROPRIETARY CLAMPING DEVICE (7.2.11)
COUPLING BALANCED TO ISO 1940-1 G6.3 (7.2.3)
COUPLING WITH HYDRAULIC FIT (7.2.10) NO
Note 6
mm
1.5 Min.
NORIGID
SPACER LENGTH
SERVICE FACTOR
couplings shall be balanced to ISO 1940-1 balance quality grade 2.5.
NOTES
5 All casing connections shall be braced with gussets in two orthogonal planes.
6 Drive train components, including but not limited to impeller, pump rotor, motor rotor, shall be dynamically balanced to ISO 1940 G1.0. Transmission units of
WINDOW ON COUPLING GUARD
COUPLING IN COMPLIANCE WITH (7.2.4)
COUPLING GUARD STANDARD PER (7.2.13.a)
REV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18 7. All pumps and drivers shall be provided with flats in two planes to permit
19 the use of hand held vibration monitoring equipment.
20
21
22
23
24
25 LOCATION OF PRESSURIZED LUBE OIL SYSTEM MOUNTED ON BASEPLATE:
26
27
CONSTRUCTION (CONT'D)
12% Cr
MATERIAL (6.12.1.1)
REDUCED HARDNESS MATERIALS REQ'D (6.12.1.12.1)
CS + Internal Coating
BASEPLATE
API BASEPLATE NUMBER:
SHAFT:
FULL TOP DECKINGBASEPLATE CONSTRUCTION (7.3.14)
BASEPLATE DRAINAGE (7.3.1)
APPENDIX H CLASS: S-6: CS / 12% Cr (Note 8)
MINIMUM DESIGN METAL TEMP (6.12.4.1)
DIFFUSERS:
CASE:
BARREL:
APPLICABLE HARDNESS STANDARD (6.12.1.12.3)
A6UE
P.O. No.:
Unit:
Sheet 4 10
Tower 03-07 Sweet Gas Plant
Item tag(s):
of
Revision:
TOW0307-P-9105A/B/C
Contract:
Inquiry No.: A6UE-4-0607-03-07-RQ-01
B Date: 20-Mar-15
-29 °C
INSPECTION CLASS:
YES
YES
- GROUT VENT HOLES
- DRAIN CONNECTION
SUPPLIED WITH:
MOUNTING PADS SIZED FOR BASEPLATES LEVELING (7.3.5)
ENTIRE BASEPLATE DRAIN RIM
MOUNTING: BOLTED ON STEEL WORK
NON-GROUT CONSTRUCTION: (7.3.13) REQUIRED
VERTICAL LEVELING SCREWS: REQUIRED
LONGITUDINAL DRIVER POSITIONING SCREWS: REQUIRED
YES
MOUNTING PADS TO BE MACHINED (7.3.6)
BEARINGS AND LUBRICATION (6.10.1.1)
BEARING (TYPE / NUMBER): (6.11.4)
BOWL (IF VS TYPE):
AISI 4140
IMPELLER WEAR RING:
IMPELLER:
CASE WEAR RING:
12% Cr
/
/
PRESSURIZED LUBE OIL SYSTEM MTD. ON PUMP BASEPLATE
PRESSURE LUBE SYSTEM TO ISO 10438- (9.2.6.5)
THRUST
RADIAL
INTERCONNECTING PIPING PROVIDED BY: SUPPLIER
8. API D2 Super Duplex SS (A 890 grade 5A or 6A) shall be quoted as an option.
ISO 10438 DATA SHEETS ATTACHED
REVIEW AND APPROVE THRUST BEARING SIZE: (9.2.5.2.4)
LUBRICATION: (6.10.2.2) (6.11.3) (9.6.1) Oil Lubricated
CENTRIFUGAL PUMP
DATA SHEET
Note: This data sheet has been modified for that in Annex N of API 610, 11th Edition. (Note 1)
YES
NOTES
PROVIDE SPACER PLATE UNDER ALL EQUIPMENT FEET
OTHER:
engineering notes.
Please refer to specific baseplate requirements in the requisition
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
to return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished.Document Number
TOW0307-C-070-EDS-P-9105Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees
CONSTANT LEVEL OILER: REQUIRED (TRICO)
OIL VISC. ISO GRADE
NUMBER OF ACCELEROMETERS
PROVISION FOR MTG ONLY (6.10.2.10) NO
INSTRUMENTATION
MOUNTING LOCATION OF ACCELEROMETERS
NOSEE ATTACHED API-670 DATA SHEET
ACCELEROMETER (7.4.2.1)
NUMBER OF ACCELEROMETERS
NUMBER OF ACCELEROMETERS Note 7
MOUNTING LOCATION OF ACCELEROMETERS
MOUNTING LOCATION OF ACCELEROMETERS
FLAT SURFACE REQUIRED (6.10.2.11) YES
MONITORS AND CABLES SUPPLIED BY (7.4.2.4)
NUMBER PER RADIAL BEARING
NUMBER PER AXIAL BEARING
VIBRATION PROBES (7.4.2.2)
PROVISION FOR VIB. PROBES NO
NUMBER PER RADIAL BEARING
THRUST BEARING TEMP.:
PROVISION FOR VIB. PROBES NO
TEMPERATURE (7.4.2.3)
RADIAL BEARING TEMP.: °C
PRESSURE GAGE TYPE:
TEMP GAGES (WITH THERMOWELLS) (9.1.3.6) NO
NUMBER PER THRUST BEARING INACTIVE SIDE
°C
NUMBER PER THRUST BEARING ACTIVE SIDE
Remarks
SOCKET WELD CONN ON SEAL GLAND (7.5.2.8)
N/A
YES
YES
HEATING MEDIUM
TOTAL COOLING WATER: m³/s
m³/s
HEATING AND COOLING (6.1.17)
COOLING WATER PIPING PLAN
COOLING WATER PIPING
N/AHEATING JACKET REQ'D (6.8.11)
INTERCONNECTING PIPING BY: SUPPLIER
SEAL SUPPORT SYSTEM MOUNTING
SEAL SUPPORT MOUNTED ON PUMP BASEPLATE (7.5.1.4):
IDENTIFY LOCATION ON BASEPLATE:
YES
COOLING REQ'D
FITTINGS
COOLING WATER PIPING MATERIALS
COOLING WATER REQUIREMENTS:
BEARING HOUSING:
HEAT EXCHANGER:
NO
ADDITIONAL CENTRAL FLUSH PORT (6.8.9)
SEE ATTACHED ISO 21049/API 682 DATA SHEET YES
MECHANICAL SEAL (6.8.1)
MANIFOLD PIPING FOR PURCHASER CONNECTION (7.5.1.6)
VENT
DRAIN
COOLING WATER
TAG ALL ORIFICES (7.5.2.4)
m³/s
PIPING & APPURTENANCES
OTHER:
HEATING PIPING:
REV
1
2
3
4 SPECIFICATION NUMBER:
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
A6UE
P.O. No.:
Unit:
Sheet
Contract:
TOW0307-P-9105A/B/C
5 10
A6UE-4-0607-03-07-RQ-01Inquiry No.:
Item tag(s):
of
Revision: B Date: 20-Mar-15
Tower 03-07 Sweet Gas Plant
TESTSURFACE PREPARATION AND PAINT
PUMP SURFACE PREPARATION:
PRIMER:
YESSUPPLIER'S STANDARD
OTHER (SEE BELOW)
PUMP:
BASEPLATE:
BASEPLATE SURFACE PREPARATION:
PRIMER:
SHIPPING & STORAGE CONTAINER FOR VERT. STORAGE (9.2.8.3)
ROTOR STORAGE ORIENTATION (9.2.8.2)
SPARE ROTOR ASSEMBLY PACKAGED FOR:
YES
YESOUTDOOR STORAGE MORE THAN 6 MONTHS
EXPORT BOXING REQUIRED
FINISH COAT:
DETAILS OF LIFTING DEVICES:
SHIPMENT: (8.4.1) EXPORT
FINISH COAT:
START-UP YES
NORMAL MAINTENANCE
WEIGHTS kg
SPARE PARTS
ITEM No. TOTALBASEGEAR
N2 PURGE (9.2.8.4)
DRIVERPUMP
MATERIAL CERTIFICATION REQUIRED:
Note 9 (6.12.1.8)
RADIOGRAPHY
LIQUID PENETRANT
ULTRASONIC
SHOP INSPECTION (8.1.1)
PERFORMANCE CURVE & DATA APPROVAL PRIOR TO SHIPMENT
TEST WITH SUBSTITUTE SEAL (8.3.3.2.b)
IMPELLER
CASING
SHAFT
YES
YES
NO
YES
YESCASTING REPAIR WELD PROCEDURE APPR. REQ'D (6.12.2.5)(6.12.3.1)
(6.12.3.4.e) MAG PARTICLE
INSPECTION REQUIRED FOR CONNECTION WELDS (6.12.3.4.d)
YES
YES
YES
OTHER
LIQUID PENETRANT YES
ULTRASONIC
MAG PARTICLE YES
RADIOGRAPHY
YES
INSPECTION REQUIRED FOR CASTINGS
PMI TESTING REQUIRED (8.2.2.8)
COMPONENTS TO BE TESTED:
FOR
METHOD
HARDNESS TEST REQUIRED (8.2.2.7)
ADDITIONAL SUBSURFACE EXAMINATION (6.12.1.5)(8.2.1.3)
NO
NO
RESIDUAL BALANCE TEST (J.4.1.2)
YESNOTIFICATION OF SUCCESSFUL SHOP PER. TEST (8.1.1.c)(8.3.3.5)
CENTRIFUGAL PUMP
DATA SHEET
Note: This data sheet has been modified for that in Annex N of API 610, 11th Edition. (Note 1)
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
Document NumberTOW0307-C-070-EDS-P-9105
Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agreesto return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished.
DYNAMIC BALANCE ROTOR (6.9.4.4) YES
MODAL ANALYSIS REQUIRED (9.3.9.2)
LATERAL ANALYSIS REQUIRED (9.1.3.4)(9.2.4.1.3)
OTHER PURCHASER REQUIREMENTS
OPERATION TO TRIP SPEED
MAX DIA. IMPELLERS AND / OR NO. OF STAGES
YES
MAXIMUM DISCHARGE PRESSURE TO INCLUDE
COORDINATION MEETING REQUIRED (10.1.3)
MAX RELATIVE DENSITY
ADDITIONAL DATA REQUIRING 20 YEARS RETENTION (8.2.1.1)
YES
CONNECTION DESIGN APPROVAL (9.2.1.4)
TORSIONAL ANALYSIS / REPORT (6.9.2.10)
PROGRESS REPORTS
OUTLINE OF PROC FOR OPTIONAL TESTS (10.2.5)
FLANGES REQ'D INPLACE OF SKT WELD UNIONS (7.5.2.8)
INCLUDE PLOTTED VIBRATION SPECTRA (6.9.3.3)
YES
IGNITION HAZARD ASSMT TO EN 13463-1 (7.2.13.e)
CASING RETIREMENT THICKNESS DRAWING (10.3.2.3)
INSTALLATION LIST IN PROPOSAL (10.2.3.1)
VFD STEADY STATE DAMPED RESPONSE ANALYSIS (6.9.2.3)
TRANSIENT TORSIONAL RESPONSE (6.9.2.4)
BEARING LIFE CALCULATIONS REQUIRED (6.10.1.6)
CADMIUM PLATED BOLTS PROHIBITED
VENDOR TO KEEP REPAIR AND HT RCDS (8.2.1.1.C)
VENDOR TO SUBMIT TEST PROCEDURES (8.3.1.1)
SUBMIT INSPECTION CHECK LIST (8.1.5)
YES
YES
CONNECTION BOLTING (7.5.1.7)
YES
YES
YESBASEPLATE TEST (7.3.21)
STRUCTURAL RESONANCE TEST (9.3.9.2)
NOZZLE LOAD TEST
4 HR. MECH RUN TEST AFTER OIL TEMP STABLE (8.3.4.2.1)
COMPLETE UNIT TEST (8.3.4.4.1)
LOCATION OF AUX. EQUIPMENT TEST
EQUIPMENT TO BE INCLUDE IN AUX TESTS
HYDROSTATIC
HYDROSTATIC TEST OF BOWLS & COLUMN (9.3.13.2)
PERFORMANCE TEST
TEST IN COMPLIANCE WITH (8.3.3.2)
TEST DATA POINTS TO (8.3.3.3)
OBSERVE
OBSERVE
OBSERVENPSH (8.3.4.3.1)(8.3.4.3.4)
NPSH-1ST STAGE ONLY (8.3.4.3.2)
TEST TOLERANCES TO (8.3.3.4)
OBSERVE
NON-WIT
OBSERVE
4 HR. MECH RUN TEST (8.3.4.2.2)
BEARING HOUSING RESONANCE TEST (8.3.4.7)
SOUND LEVEL TEST (8.3.4.5)
CLEANLINESS PRIOR TO FINAL ASSEMBLY (8.2.2.6)
LOCATION OF CLEANLINESS INSPECTION
CHECK FOR CO-PLANAR MOUNTING PAD SURFACES
MECHANICAL RUN TEST UNTIL OIL TEMP STABLE
REMOVE CASING AFTER TEST
PER ASME SECTION VIII
PER EN 13445IMPACT TEST (6.12.4.3)
OBSERVE
REMOVE / INSPECT HYDRODYNAMIC BRGS. AFTER TEST (9.2.7.5)
AUXILIARY EQUIPMENT TEST (8.3.4.6)
RETEST ON SEAL LEAKAGE (8.3.3.2.d)
RETEST REQUIRED AFTER FINAL HEAD ADJ. (8.3.3.7.b)
NPSH TESTING TO HI 1.6 OR ISO 9906 (8.3.4.3.3)
TEST NPSHA LIMITED TO 110% SITE NPSHA (8.3.3.6)
REV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
PRESSURE VESSEL DESIGN CODE REFERENCES
THESE REFERENCES MUST BE LISTED BY THE SUPPLIER:
CASTING FACTORS USED IN DESIGN (TABLE 3)
SOURCE OF MATERIAL PROPERTIES
A6UE-4-0607-03-07-RQ-01
10of
Inquiry No.:
WELDING AND REPAIRS (Please Refer to ECA-WELD-S01)
THESE REFERENCES MUST BE LISTED BY THE PURCHASER (DEFAULT TO TABLE 10 IF NO PURCHASER PREFERENCE IS STATED)
ALTERNATIVE WELDING CODES AND STANDARDS
WELDING REQUIREMENT (APPLICABLE CODE OR STANDARD)
WELDER/OPERATOR QUALIFICATION
WELDING PROCEDURE QUALIFICATION
A6UE
Tower 03-07 Sweet Gas Plant
Item tag(s):
Contract:
Unit:
Sheet 6
TOW0307-P-9105A/B/C
Revision:
P.O. No.:
B Date: 20-Mar-15
NON-PRESSURE RETAINING STRUCTURAL WELDING SUCH AS BASEPLATES OR SUPPORTS
THESE REFERENCES MUST BE LISTED BY THE PURCHASER DEFAULT TO TABLE 15 YES
MATERIAL INSPECTION
MAGNETIC PARTICLE OR LIQUID PENETRANT EXAMINATION OF PLATE EDGES
POSTWELD HEAT TREATMENT
POSTWELD HEAT TREATMENT OF CASING FABRICATION WELDS
ALTERNATIVE MATERIAL INSPECTIONS AND ACCEPTANCE CRITERIA (SEE TABLE 14 ) (8.2.2.5)
FOR CASTINGSFOR FABRICATIONS
VISUAL INSPECTION (ALL SURFACES)
TYPE OF INSPECTION
RADIOGRAPHY
ULTRASONIC INSPECTION
MAGNETIC PARTICLE INSPECTION
LIQUID PENETRANT INSPECTION
METHOD
CENTRIFUGAL PUMP
DATA SHEET
Note: This data sheet has been modified for that in Annex N of API 610, 11th Edition. (Note 1)
28
29
30 Purchaser's authorized inspector shall verify the surface flatness and surface finish of the machined underside of the baseplates.
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
to return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished.Document Number
TOW0307-C-070-EDS-P-9105Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees
NOTES
A516 Gr. 70N; Alloy Components: A352 - CA6NM
This activity shall be witnessed by Purchaser's inspector during final release inspection.
11 Auxiliary system materials shall be low temperature carbon steel where applicable, A333-6, A350 LF2 Cl1, A352 - LCB/LCC,
Material certificates shall be provided for casings, cover, impellers, shafts9
10
REV
1
2
3 Pump and System Curves
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24 System Sketch
25
26
27
CENTRIFUGAL PUMP
DATA SHEET
Note: This data sheet has been modified for that in Annex N of API 610, 11th Edition. (Note 1)
Item tag(s):
Contract:
Unit:
B
A6UE
TOW0307-P-9105A/B/C
Date: 20-Mar-15
Tower 03-07 Sweet Gas Plant
Revision:
A6UE-4-0607-03-07-RQ-01
10of
Inquiry No.:
P.O. No.:
Sheet 7
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
to return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished.Document Number
TOW0307-C-070-EDS-P-9105Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees
REV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
Client: Encana Corporation Vendor:
Service: FRAC Water Supply Pumps Plant: Tower 03-07 Sweet Gas Plant
No. Required: 3 Site: Dawson Creek, BC, Canada
20-Mar-15
Unit: Tower 03-07 Sweet Gas Plant
Note: This data sheet has been modified from that in the annex of API Standard 682, Third Edition.
P.O. No.:
Inquiry No.: A6UE-4-0607-03-07-RQ-01
Sheet 8
MECHANICAL SEAL DATA SHEET
Contract: A6UE
Item No: TOW0307-P-9105A/B/C
Revision:
of 10
By Manufacturer or Purchaser
Seal Specification - (Ref. 4.1, Figures 1 to 6)
CATEGORY Seal Category 1 Seal Category 2 Seal Category 3
NOTES: Information Below to be Completed : By Purchaser By Manufacturer
Seal Code (Annex D)
TYPE Type A (3.72) Type B (3.73) Alternate Stationary (Type A&B)
Single Spring (Type A)
ARR'GT Default Configuration Alternate Design Flush Plans (See Annex G)
Alternate Rotating (Type C)
1 (3.2) 1CW-FX
(CODE CW) Type C (3.74)
62Alternative Bush 02
13 23 501CW-FL Dist. Flush 01
1114 31 51
32 612 (3.3)
Bu
ffer Liquid 2CW-CW FX
21
Gas 2CW-CS 2NC-CS FX 21Dist. Flush 11
75Tangential LBO Connection 02 14
23 41 62Dist. Flush 01 1376
3 (3.4)
Ba
rrie
r Liquid 3CW-FB 3CW-BB FX
3NC-FF3NC-BB
31 52 7132 61 72
02 14 53B
61 54
3CW-FF Tang. LBO Conn.
01 13 53A
62
Gas
MATERIALS (REFERENCE 6.1.6 & ANNEX B)
SECONDARY SEALS SEAL FACES METAL BELLOWS SPRINGS METAL PARTS
74
SLEEVE-SHAFT DRIVE Set-Screw Onto Shaft Alternative (6.1.3.13) SPECIFY :
11 32 53C3NC-FB
UNS N10276 (TypeB) UNS N10276 UNS S31600 / S31635FKM FFKM CARBON vs SIC
or UNS N06455 UNS N10276
EPM / EPDM SS-SIC RB-SIC UNS N08020
Spiral Wound Gasket SIC vs SIC UNS N07718 (TypeC)
UNS S31600 UNS N08020
NBR vs
Other :
Other : or UNS S31635 Other :
B Date:
28
29
30
31
32 /33
34
35
36
37
38
39
40
41
42
43
44
45
46 /
47
48
49
50
51
52
53
54
55
56
57
58
59
60
Data Requirements Form (Annex J) Static Sealing Pressure Rating (3.69) : kPa g
MECHANICAL SEAL DATA
Seal Vendor : John Crane Dynamic Sealing Pressure Rating (3.19) : kPa g
°C
Seal Drawing No. : Min. Design Metal Temperature (6.1.6.11.1): -29 °C
Size / Type : Maximum Allowable Temperature (3.40) :
Alternative Seal For Pump Performance Test Total Seal Axial Thrust on Shaft : N
kW
Modified Faces For Pump Performance Test Heat Soak at Normal Conditions : kW
Vendor's Seal Code : Generated Heat at Normal Conditions :
SEAL CHAMBER DATA (REFERENCE 6.1.2.4)
ISO 13709 ASME B73.1&2 Cylindrical
Bolt-On Chamber (6.1.2.5) Seal Chamber Flush Port Req'd Seal Chamber Vent Req'd
Tapered ISO 3069-C Other :
Case Material :
Chamber Cooling
PUMP DATA - Refer to Sheet 2
Manufacturer : Model :
Floating Throat Bushing Fixed Throat Bushing Chamber Heating
Discharge Press. : kPa g
Size :
kPa g MSSP (3.44) :
Suction Press. (Rated) : kPa g
Shaft Horizontal Vertical Diameter :
Seal Chamber Press. Normal : kPa g Min / Max MDSP :
Pump Operating Pressure
Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees Document Numberto return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished. TOW0307-C-070-EDS-P-9105
NOTES
14. Supplier to confirm the seal selection and arrangement
Shaft Speed : RPM
Shaft Rotation (Viewed From Driver) : CCW CW
kPa g
REV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17 /
18 /
19 /
20 /
21
22
23
24
25 /
26 /
27
FLUID DATA
PUMPED STREAM
Pour pt:
20-Mar-15
Unit: Tower 03-07 Sweet Gas Plant
Note: This data sheet has been modified from that in the annex of API Standard 682, Third Edition.
P.O. No.:
Inquiry No.: A6UE-4-0607-03-07-RQ-01
Sheet 9
MECHANICAL SEAL DATA SHEET
Contract: A6UE
Item No: TOW0307-P-9105A/B/C
Revision:
of 10
Dissolved Contaminant H2S ppm Wet
Type or Name : Concentration : % Fluid Solid at Ambient
Hazardous Flammable
°C
Solidifies: °C
Pumped Stream Solidifies Under ShearSolid Contaminant Pumped Stream Contains Agents That Polymerize
Other : @ ppmCl2 ppm
Specify Agents : @ Temp : °CPumping Temp. Min °C
Concentration : Mass Fraction
Vapor Pressure Pumped Stream is Regulated For Fugitive or Other Emissions
Pumped Stream Can Plate Out or Decompose :Spec. Gravity at Norm Temp: at Max Temp: Specify Conditions :
Norm °C Max °C
kpaa Regulation Level : ppmAtmos. Boiling pt Visc. At Norm Pump Temp
at Norm Temp: kpaa at Max Temp:
cP Special Pump Cleaning Procedures:
Alt. Process Fluids(incl. Commissioning) Specify
FLUSH FLUID (PLAN 32) If flush is pumpage, then flush data is not req'd Vapor Pressure
Type or Name : Conc'n : % kpaa
Seal Vendor Review Required Atmos. Boiling pt °C Visc. at Norm Pump Temp
@ Norm Temp kpaa @ Max Temp
cP
Fluid Temp Min Norm Max
kpaa
QUENCH MEDIUM (PLAN 51, 62) Supply Temperature Max. / Min. : ppm
m3/hr
Spec. Gravity at Temp Indct'd @ Norm Temp @ Max Temp Pressure Req'd Max / Min
Flow Rate Req'd Max / Min
@ Max. Temp. :
Purchaser Selection Seal Vendor Selection Vapor Pressure at
m3/hr
BUFFER / BARRIER MEDIUM Specific Gravity:
Type or Name : @ Normal Temperature :
Type or Name : Flow Rate Required Max. / Min. :
kpaa Max. Temp : kpaa
Flow Rate Required Max. / Min. : m3/hr
Seal Vendor Review Purchaser Review Normal Temperature :
cP
Fluid Temperature Specific Heat Capacity at Const. Press.: kJ/kgK
Atmospheric Boiling Point °C
Supply Pressure Max. / Min. : kpag Viscosity at Normal Pump Temperature :
B Date:
28
29
30
31
32 /
33 /
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
Unclassified
SITE AND UTILITIES
Control Voltage V : P :
Max. : °C Cooling / Heating RequiredMin. : °C Normal : °C
Cl2 : ppm
Area Classification CL. Zone.
Hz: Cooling Water Supply Temp °C
kpagDiv. Cooling Water Press. Norm/Design :
ACCESSORIES (Clauses 8 and 9)
GENERAL PLAN 11, 12, 13, 14, 21, 23, 31, 32 and 41 SYSTEMS
Joint User / Vendor Layout of Equipment (8.1.4) Connecting Line Supplier :
CAT
TCLASS
Design Ambient (Min. / Max.) : °C ATEX (Ex Directive 94/9/EC): GR
Tubing Piping (8.5.2.2)
Special Requirements For Hazardous Service : Restriction Orifice Nipple in Flush Line (8.5.2.4)
Pipe Taper Threads (8.1.9) ISO 7 ASME B1.20.1
Define : Cyclone Separator Supplier :
Special Cleaning and Decontamination Requirements Plan 32 Equipment Supplier :
Type and Spec. of Heat Tracing (8.6.5.8)
PLAN 72 and 74 SYSTEM
Utility Manifold Connections Required (8.4.4) Plan 32 Flow Indicator Plan 32 Temp. Indicator
ISO 15649 Equipment Supplier :
Thermal Relief Valves Required (9.8.3) Equipment Supplier :COOLING SYSTEM (PLAN 21,22,23,41,53B,53C) High Flow Alarm Switch (8.6.6.5)
Galvanized Piping (8.4.2)
Equipment Reference / Code : High Flow Alarm Switch For Plan 75(8.6.5.3)Cooling Water Line Supplier : Test Connection (8.6.5.4)
Heat Exchanger Supplier : PLAN 75 and 76 SYSTEMWater Cooled Air Cooled
Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees Document Numberto return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished. TOW0307-C-070-EDS-P-9105
Closed
NOTES
Cooling Water Flow Rate : m3/hr
Sight Flow Indicators (8.4.3) Open
Tubing
REV
1
2
3
4
5
6 /
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
TOW0307-P-9105A/B/C
Revision:
of 10
ACCESSORIES (Clauses 8 and 9) CONT'D
PLAN 52 and 53 SYSTEMS EN 13445 or Other Code Applicable
20-Mar-15
Unit: Tower 03-07 Sweet Gas Plant
Note: This data sheet has been modified from that in the annex of API Standard 682, Third Edition.
P.O. No.:
Inquiry No.: A6UE-4-0607-03-07-RQ-01
Sheet 10
MECHANICAL SEAL DATA SHEET
Contract: A6UE
Item No:
Reservoir MAWP (3.4.1) psig
galDimensional Variations To Standard Figure G27 NLL to Gland Plate Height ft
Standard (Fig. G27) Alternative (Fig. G28) Reservoir Capacity (8.5.4.3) :
B
Alternative Fabrication Standard : Temperature Indicator (Plan 53B,53C)
psig
System Hold-Up Period (Plans 53B & 53C) : days
Dimensional Variations To Standard Figure G28 Set Pressure Range, Max. / Min.
Primary Equipment Supplier : PRESSURE SWITCH (8.5.4.2.h) TO ACTIVATE ON :Supplier Reference / Code :
psigTubing SCH. 80 Piping (8.5.4.4.9) High Level Alarm Required (8.5.4.2.i)
Rising Pressure (Arr 2) Set at : psigConnecting Line Supplier : Falling Pressure (Arr 3) Set at :
Equipment Support Supplier : Test Based H / Q Curve For Internal Circulating Device
Filling System Supplier : External Circulating Pump (8.6.3.1)
User Specification Reference For Instrument / Controls :
MPSTD-A-000-GEN-00042-0000
PRESSURE GAUGES (9.4)
Oil Filled Pressure Gauges (9.4.3)
ASME Code Stamp Required
INSTRUMENTATION
Transmitters (9.5.3.2)
Hydrostatic Capacitance Ultrasonic
Pressure Switches (9.5.2) Transmitters (9.5.2.3) Level Switches (9.5.3)
LEVEL INDICATORS (9.6)
Weld Pad External, Removable (9.6.2)
Flow Instruments (9.7) Transmitters (9.7.3)
Date:
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
INSPECTION AND TESTING
Purchaser Participation in Inspection & Test 100% Inspection of All Welds (6.1.6.10.5) Using :
Liquid Penetrant
Inspector's Check List (10.1.7 & Annex H) Radiographic Ultrasonic
Specify : Magnetic Particle
Hardness Test (10.2.3k) Required For : Alternate Seal Pump Test (10.3.5.2) See Page 2 Line 32
Purchaser Approval Req'd For Welded Optional Qualification Testing Required (10.3.1.1.2)
Connection Design (6.1.6.10.5) Mod. Faces For Pump Test (10.3.5.1) See Page 2 Line 31
NOTES
Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees Document Numberto return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished. TOW0307-C-070-EDS-P-9105
FORM 085 265 F0181 (12Mar02)
Page 1 of 1
Data Sheet - LV Motors
Tag No.: TOW0307-PM-9104A/B/C Client: Encana Corporation
Service: Produced Water Disposal Pump Project: Cutbank Ridge Program
RFQ No.: A6UE-4-0607-03-07-RQ-01 Contract No.: A6UE
By: ACG Rev. B Date: 03/23/2015 Ck By: KZ Location: Dawson Creek, BC
Document No.: TOW0307-P-070-DSX-PM-9104
ELECTRICAL AREA CLASSIFICATION:
DRIVE TYPE: Will be specified later
UNCLASSIFIED
DRIVE MFG.: MODEL: Will be specified later
CLASS: GP: ZONE: AUTO IGN. TEMP:
CONSTANT TORQUE LOAD VARIABLE TORQUE LOAD
AMBIENT TEMP: MIN: -40°C MAX: +35°C
(NOTE 4) SPEED RANGE: Will be specified at later stage
ELEVATION: 795.6 MSL
OTHER REQUIRMENTS:
SEISMIC CONDITIONS: Sa(0.2) = 0.132, Sa(0.5) = 0.08, Sa(1.0) = 0.04, Sa(2.0) = 0.073
NAMEPLATE kW: TBD SERVICE FACTOR: 1.0 MANUFACTURER: TBD
VOLTAGE: 575V PHASE: 3 HZ.: 60 MODEL: TBD
SYN SPEED: TBD FRAME: TBD
INSULATION CLASS: F RISE CLASS: B
MANUFACTURER'S DATA
DRIVEN EQUIP VENDOR AND/OR MOTOR VENDOR TO COMPLETE ALL APPLICABLE BLANKS NOT COMPLETED BY PURCHASER
DESIGN DATA - MECHANICAL PERFORMANCE DATA
SITE CONDITIONS
DESIGN DATA - ELECTRICAL
VARIABLE FREQUENCY DRIVE APPLICATIONS
ENCLOSURE: TEFC TEFC-EP TENV FLA TBD LRA TBD STATOR TEMP RISE: TBD
OTHER FULL LOAD SPEED: TBD RPM
LOAD CONNECTION:
LOADING FULL 3/4 1/2
DIRECT CONNECTED BELT CONNECTED
EFFICIENCY
MOUNTING POSITION:
POWER FACTOR
HORIZONTAL VERTICAL
SHAFT POSITION (for vertical mounting):
SHAFT UP SHAFT DOWN
1-
NEMA TORQUE DESIGN: TBD MOTOR THRUST LOAD: TBD
ROTATION: TBD 2- Motors over 75 kW shall be supplied with space heater.
3- Motors will be controlled by ASD.
CW CCW BI-DIRECTIONAL 4-
(Facing end opposite drive shaft)
SPECIAL REQUIREMENTS:
COMMENTS: 1. TBD: information to be provided by Supplier
2. Motors shall be in compliance with Encana specification ECA-ELEC-S-04 AC Low Voltage Induction Electric Motors.
3. Motor quantity is 3 and tagged as follows: TOW0307-PM-9104A; TOW0307-PM-9104B; TOW0307-PM-9104C
4. Design temperature for outside design conditions is min -40 to max +27 degree C and design temperature for inside design
conditions is min +10 to maximum +35 degree C. Refer to HVAC design Basis (MPSTD-R-000-PHL-10000-0000).
Description
FOR: REV.
LOCATION:
Motors over 150 kW shall be equipped with at least two stator RTDs per phase for winding and one RTD per bearing for Over-Temp protection. RTDs shall be wired out to a separate auxiliary terminal box.
OTHER REQUIREMENTS
B 23-Mar-15 Issued for Bid ACG KZ JT
A 09-Mar-15 Issued for Review RC JT MN
NO. DATE By Chk'd Appr'd Job # A6UE
Motors rated 75 kW to 149 kW shall be equipped with a minimum of one RTD per phase. RTD will be individually wired out to a separate auxilliary box.
SWEET GAS PLANT DOCUMENT NO.
DAWSON CREEK, BC TOW0307-P-070-DSX-PM-9104B
LOW VOLTAGE MOTOR
DATA SHEET
SERVICE: Page 1 of 1Produced Water Disposal Pump
FORM 085 265 F0181 (12Mar02)
Page 1 of 1
Data Sheet - LV Motors
Tag No.: TOW0307-PM-9105A/B/C Client: Encana Corporation
Service: Frac Water Supply Pumps Project: Cutbank Ridge Program
RFQ No.: A6UE-4-0607-03-07-RQ-01 Contract No.: A6UE
By: ACG Rev. B Date: 03/23/2015 Ck By: KZ Location: Dawson Creek, BC
Document No.: TOW0307-P-070-DSX-PM-9105
ELECTRICAL AREA CLASSIFICATION:
DRIVE TYPE: Will be specified later
UNCLASSIFIED
DRIVE MFG.: MODEL: Will be specified later
CLASS: GP: ZONE: AUTO IGN. TEMP:
CONSTANT TORQUE LOAD VARIABLE TORQUE LOAD
AMBIENT TEMP: MIN: -40°C MAX: +35°C
(NOTE 4) SPEED RANGE: Will be specified at later stage
ELEVATION: 795.6 MSL
OTHER REQUIRMENTS:
SEISMIC CONDITIONS: Sa(0.2) = 0.132, Sa(0.5) = 0.08, Sa(1.0) = 0.04, Sa(2.0) = 0.073
NAMEPLATE kW: TBD SERVICE FACTOR: 1.0 MANUFACTURER: TBD
VOLTAGE: 575V PHASE: 3 HZ.: 60 MODEL: TBD
SYN SPEED: TBD FRAME: TBD
INSULATION CLASS: F RISE CLASS: B
MANUFACTURER'S DATA
DRIVEN EQUIP VENDOR AND/OR MOTOR VENDOR TO COMPLETE ALL APPLICABLE BLANKS NOT COMPLETED BY PURCHASER
DESIGN DATA - MECHANICAL PERFORMANCE DATA
SITE CONDITIONS
DESIGN DATA - ELECTRICAL
VARIABLE FREQUENCY DRIVE APPLICATIONS
ENCLOSURE: TEFC TEFC-EP TENV FLA TBD LRA TBD STATOR TEMP RISE: TBD
OTHER FULL LOAD SPEED: TBD RPM
LOAD CONNECTION:
LOADING FULL 3/4 1/2
DIRECT CONNECTED BELT CONNECTED
EFFICIENCY
MOUNTING POSITION:
POWER FACTOR
HORIZONTAL VERTICAL
SHAFT POSITION (for vertical mounting):
SHAFT UP SHAFT DOWN
1-
NEMA TORQUE DESIGN: TBD MOTOR THRUST LOAD: TBD
ROTATION: TBD 2- Motors over 75 kW shall be supplied with space heater.
3- Motors will be controlled by ASD.
CW CCW BI-DIRECTIONAL 4-
(Facing end opposite drive shaft)
SPECIAL REQUIREMENTS:
COMMENTS: 1. TBD: information to be provided by Supplier
2. Motors shall be in compliance with Encana specification ECA-ELEC-S-04 AC Low Voltage Induction Electric Motors.
3. Motor quantity is 3 and tagged as follows: TOW0307-PM-9105A; TOW0307-PM-9105B; TOW0307-PM-9105C
4. Design temperature for outside design conditions is min -40 to max +27 degree C and design temperature for inside design
conditions is min +10 to maximum +35 degree C. Refer to HVAC design Basis (MPSTD-R-000-PHL-10000-0000).
Description
FOR: REV.
LOCATION:
Motors over 150 kW shall be equipped with at least two stator RTDs per phase for winding and one RTD per bearing for Over-Temp protection. RTDs shall be wired out to a separate auxiliary terminal box.
OTHER REQUIREMENTS
Motors rated 75 kW to 149 kW shall be equipped with a minimum of one RTD per phase. RTD will be individually wired out to a separate auxilliary box.
NO. DATE
LOW VOLTAGE MOTOR
DATA SHEET
A 09-Mar-15 Issued for Review RC JT MN
B 23-Mar-15 Issued for Bid ACG KZ JT
DAWSON CREEK, BC TOW0307-P-070-DSX-PM-9105B
By Chk'd Appr'd
SWEET GAS PLANT DOCUMENT NO.
Job # A6UE
SERVICE: Page 1 of 1Frac Water Supply Pumps