claims taken from blp’s website regarding ciht this presentation takes snippets off of blacklight...

20
Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims, data and independent validation reports. Blacklight Power’s website is: http://www.blacklightpower.com

Upload: damaris-mcmillan

Post on 01-Apr-2015

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims.Includes claims, data and independent validation reports.

Blacklight Power’s website is:http://www.blacklightpower.com

Page 2: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

Regarding CIHT data shown in next two slides:

Energy input = 5 mA for 0.4 Seconds at an average of 0.79 Volts.Energy output = 5 mA for 4.1 Seconds at an average of 0.78 Volts

Power input = (Duty cycle)*(Volts)*(Current) = (0.4/4.5)*(0.005)*(0.79) = 0.351 mW Power Output = (Duty Cycle)*(Volts)*(Current) = (4.1/4.5)*(0.005)*(0.78) = 3.55 mW

Ratio = Output/Input = 3.55/0.351 = 11.2

Gain = (100%)*(Output/Input) = (100%)*(3.55/0.351)= 1120%

Output and input current could be measured using the exact same 1 ohm resistor (volts across resistor would be 0.005 V).Voltage across the cell remains fairly constant at 0.78 to 0.79 Volts.Total error for power measurements can easily be less than 3% with good equipment.

Page 3: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

Curr

ent

Data taken from BLP’s report on CIHT results.

Page 4: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

Volta

ge

Data taken from BLP’s report on CIHT results.

Page 5: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

http://www.blacklightpower.com/technology/ciht-cell/

http://www.blacklightpower.com/faq/

10 W unit has been tested

Page 6: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

Source:http://www.blacklightpower.com/business/business-summary

Page 7: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

Source:http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf

Page 8: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

Source:http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf

Output energy 2000 times the input

Page 9: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

Source:http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf

Page 10: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

Source:http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf

Page 11: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

11

BLP CIHT results of energy output and gain.

5000% gain;Output is 50X input here.

10000%

1000%

10%

100%

source:http://blacklightpower.com/wp-content/uploads/presentations/TechnicalPresentation.pdf

For example, at 100% Energy Gain, output is equal to input.66 days

Energy Gain

Page 12: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

Source:http://www.blacklightpower.com/technology/validation-reports

6 teams/individuals from relevent industries wrote validation reports on CIHT

Page 13: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

Source:http://www.blacklightpower.com/wp-content/uploads/pdf/WeinbergReport.pdf

Page 14: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

Source:http://www.blacklightpower.com/wp-content/uploads/pdf/CopelandReport.pdf

5476% gain means that the output is 54 times larger than the input

Page 15: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

Source:http://www.blacklightpower.com/wp-content/uploads/pdf/F500Study.pdf

200,000% gain means that the output is 2000 times larger than the input

Page 16: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

242,132% gain means that the output is 2421 times larger than the input

286% gain means that the output is 2.8 times larger than the input

Page 17: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

500% gain means that the output is 5 times larger than the input

Page 18: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Claims taken from BLP’s website regarding CIHT

Source:http://www.blacklightpower.com/wp-content/uploads/pdf/RamanujacharyReport.pdf

735% gain means that the output is 7.3 times larger than the input

Page 19: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Source:http://www.blacklightpower.com/wp-content/uploads/pdf/GlumacReport.pdf

2400 ratio of output to input !

Claims taken from BLP’s website regarding CIHT

Page 20: Claims taken from BLP’s website regarding CIHT This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims,

Source:http://www.blacklightpower.com/wp-content/uploads/pdf/ENSERReport.pdf

144028% gain means that the output is 1440 times larger than the input

Claims taken from BLP’s website regarding CIHT