cl1pad1 power adapter model user's manual€¦ · the power adapter may be damaged by dropping...

3
Side A Side B JAPANESE Side B ENGLISH SAFETY PRECAUTIONS(Read these precautions before using) Please read this manual carefully and pay special attention to safely in order to handle this product properly. Also pay careful attention to safely and handle the module properly. These precautions apply only to Mitsubishi equipment. Refer to the user’s manual of the CPU module to use for a description of the PLC system safety precautions. These SAFETY PRECAUTIONSclassify the safety precautions into two categories: "WARNING" and "CAUTION". Depending on circumstances, procedures indicated by may also be linked to serious results. In any case, it is important to follow the directions for usage. Store this manual in a safe place so that you can take it out and read it whenever necessary. Always forward it to the end user. [DESIGN PRECAUTIONS] [INSTALLATION PRECAUTIONS] [WIRING PRECAUTIONS] Procedures which may lead to a dangerous condition and cause death or serious injury if not carried out properly. Procedures which may lead to a dangerous condition and cause superficial to medium injury, or physical damage only, if not carried out properly. • Depending on a failure in the remote I/O module, the output may become the ON or OFF status. For output signals which can lead to a severe accident, install a circuit monitoring them outside the module. • Do not bind the control cable and the flat cable dedicated to CC-Link/LT together with the main circuit and the power cable. Keep such cables far from the main circuit and the power cable. Assure a distance of 100mm (3.94") or more. Otherwise, malfunction may be caused by noise. • Use the power adapter without applying any force on the connector for CC-Link/LT interface and the flat cable dedicated to CC-Link/LT. Otherwise, such cables may be broken or fail. • Use the power adapter within an environment described by the general specifications in this manual. If the power adapter is used in any environment outside the range for the general specifications, electrical shock, fire, malfunction, product damage or product deterioration may occur. • Do not directly touch the conductive area of the power adapter. Malfunction or damage of the power adapter may be caused by such touching. • Securely fix the power adapter with DIN rail or mounting screws. Securely tighten the mounting screws within the specified torque range. If the screws are insufficiently tightened, the power adapter may drop, short-circuit or malfunction. If the screws are excessively tightened, the screws may be damaged, and the power adapter may drop or short-circuit. • Install the power adapter on to a flat surface. If the mounting surface is concave and/or convex, and if excessive force is applied on the PC board, nonconformity may occur. • Make sure to shut down all phases of the power supply outside the module before starting the installation or wiring work. If all phases are not shut down, electrical shock or product damage may be caused. [STARTING AND MAINTENANCE PRECAUTIONS] [DISPOSAL PRECAUTIONS] [TRANSPORTATION AND MAINTENANCE PRECAUTIONS] Notification of CE markingThis notification does not guarantee that an entire mechanical module produced in accordance with the contents of the notification comply with the following standards. Compliance to EMC standards of the entire mechanical module should be checked by the user / manufacturer. Attention This product is designed for use in industrial applications. Standards with which this product complies Type : Programmable Controller (Open Type Equipment) Models : Products manufactured: from November 1st, 2002 to April 30th, 2006 are compliant with EN61000-6-4 and EN61131-2:1994+A11:1996+A12:2000 after May 1st, 2006 are compliant with EN61131-2:2007 Confirm the rated voltage and the terminal arrangement of the power adapter, then correctly wire the power adapter. If a power supply not conforming to the specification rating is connected or the power adapter is wired incorrectly, fire, failure or malfunction may occur. Tighten the terminal screws within the specified torque range. If the terminal screws are insufficiently tightened, fire or malfunction may occur. If the terminal screws are excessively tightened, the screws may be damaged, and the module may short-circuit, equipment failures, or malfunction. Make sure that foreign objects such as cutting and wire chips do not enter the power adapter. Fire, failure or malfunction may be caused by the foreign objects. Attach a warning label (hazard symbol 417-IEC-5036) concerning electric shock to the panel. Do not touch the terminals while the power is being supplied. Electrical shock or malfunction may be caused by such touching. Shut down all phases of the power supply outside the power adapter before cleaning or tightening the terminal screws. If all phases are not shut down, the power adapter may fail or malfunction. Do not disassemble or modify the power adapter. Failure, malfunction, injury or fire may be caused by disassembly or modification. The power adapter case is made of resin. Do not drop it. Do not apply strong impact to it. The power adapter may be damaged by dropping or strong impact. Shut down all phases of the power supply outside the power adapter before attaching or removing the power adapter to/from the panel. If all phases are not shut down, the power adapter may fail or malfunction. When disposing of the product, treat it as an industrial waste. During transportation avoid any impact as the module is a precision instrument. Doing so could cause trouble in the module. If is necessary to check the operation of module after transportation, in case of any impact damage. Electromagnetic Compatibility Standards (EMC) Remark EN61000-6-4:2001 Electromagnetic compatibility -Generic standards - Emission standard for Industrial environment Compliance with all relevant aspects of the standard. (Radiated Emissions and Mains Terminal Voltage Emissions) EN61131-2:1994/A11:1996/A12:2000 Programmable controllers -Equipment requirements and tests Compliance with all relevant aspects of the standard. Radiated electromagnetic field Fast transient burst Electrostatic discharge Damped oscillatory wave EN61131-2: 2007 Programmable controllers -Equipment requirements and tests Compliance with all relevant aspects of the standard. EMI Radiated Emission Conducted Emission EMS Radiated electromagnetic field Fast transient burst Electrostatic discharge High-energy surge Voltage drops and interruptions Conducted RF Power frequency magnetic field For more details please contact the local Mitsubishi Electric sales site. • Notes for compliance to EMC LVD regulation. It is necessary to install the CL1 series module in a shielded metal control panel. Use this product in Zone A *1 as defined in EN61131-2. *1 Zone defined in EN61131-2 Separation defined in EN61131-2 for EMC LVD regulation decided depending on condition in industrial setting. Zone C = Factory mains which is isolated from public mains by dedicated transformers. Zone B = Dedicated power distribution which is protected by secondary surge protection. (300V or less in the rated voltage is assumed.) Zone A = Local power distribution which is isolated from dedicated power distribution by AC/DC converters, isolation transformers, etc. (120V or less in the rated voltage is assumed.) When the following models use the CC-Link/LT power adapter model (CL1PAD1), a power line connecting to the external power supply terminal of the CL1PAD must be 30m(98’5’’) or less. - CL2AD4-B - CL2DA2-B 1. Outline of Product This product is a power adapter connected to CC-Link/LT. This product supplies 24V DC power from an external power supply to the CC-Link/LT system. At least one power adapter is required per CC-Link/LT system. 2. Name of Each Part 2.1 Name of each part and assignment DIN rail installation groove Power terminal 2-φ4.5 mounting hole (M4 mounting screw) Status indicator LED LINK connector LINK/POWER connector Terminal arrangement 24G +24V Name Description Status indicator LED POWER Lit while the power is supplied Interface LINK connector DB For communication DA For communication LINK/POWER connector 24G Power supply for communication (-) DB For communication DA For communication +24V Power supply for communication (+) Power terminal +24V Supplies power from outside to power adapter. Input voltage: 28.8V DC or less (depending on connected model) Rated input current: 5.0 A (Use a proper external power supply under consideration of initial current of remote I/O modules.) 24G 2.2 Handling of LINK connector and LINK/POWER connector 1) LINK connector 2) LINK/POWER connector LINK connector: Executes only communication (does not supply power). Used when two or more power adapters are used in the CC-Link/LT system. LINK/POWER connector: Executes communication, and supplies the power to the CC-Link/LT system. 3. Specifications 1) General specifications *1 The criterion is shown in IEC61131-2. *2 The module cannot be used in an environment pressurized above the atmospheric pressure which can be generated around the altitude of 0 m. If the module is used in such an environment, it may fail. *3 It indicates in which wiring area from the public wiring net to the mechanical module inside the site the equipment is assumed to be connected. The category ΙΙ applies, for example, to equipment whose power is supplied from a fixed facility. The surge-resistant voltage of equipment whose rating is up to 300V is 2,500V. Master module Power adapter Power adapter External power supply External power supply 1) 2) 1) 2) Item Specification Ambient working temperature 0 to 55°C (32 to 131°F) Ambient storage temperature -25 to 75°C (-13 to 167°F) Ambient operating humidity 5 to 95%RH: Dew condensation shall not be allowed. Ambient storage humidity 5 to 95%RH: Dew condensation shall not be allowed. Vibration resistance (*1) Intermittent vibration is present Number of sweep times Frequency Acceleration Half amplitude 10 times in each of X, Y and Z directions (80 min) 10 to 57Hz 0.075mm 57 to 150Hz 9.8m/s 2 Continuous vibration is present Frequency Acceleration Half amplitude 10 to 57Hz 0.035mm 57 to 150Hz 4.9m/s 2 Impact resistance (*1) 147 m/s 2 , 3 times in each of X, Y and Z directions Operating atmosphere Corrosive gas should not be present. Operating altitude 2,000m(6561'8") or less (*2) Installation place Inside control panel Over-voltage category ΙΙ or less (*3) Degree of contamination 2 or less (*4) Thank you very much for purchasing this product. CL1PAD1 Power Adapter Model Please read this manual thoroughly before starting to use the product and handle the product properly. User’s Manual MODEL CL1PAD1 MANUAL Number JY997D04601G Date March 2018

Upload: others

Post on 29-Sep-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CL1PAD1 Power Adapter Model User's Manual€¦ · The power adapter may be damaged by dropping or strong impact. • Shut down all phases of the power supply outside the power adapter

*4 This index indicates the degree ofthe environment in which the modu2 indicates that contamination conductive substances.In this degree, however, tempoaccidental condensation.

2) Performance specifications

4. Construction CautionsInstallation of power adaptersAt least one power adapter is requireWhen constructing the system usingthree conditions should be satisfied.If the following two conditions are nadapters in constructing the system.• The current capacity of the power

consumption should be an equival• In order to operate the system in st

equivalent to or less than 3.6 V.• The minimum operating voltage of

adapter is 20.4 V, therefore, supplyshould be equivalent to or more th

4.1 System power calculation4.1.1 Current consumption calcu

*5 Some remote I/O modules for CCflat cable dedicated to CC-Link/LT.For the details, refer to the instruct

4.1.2 Voltage dropCalculate the voltage drop based onformula. (supply voltage: 24V DC, am1) Selection based on the simplified

One power adapter is allowed above.

Item

Voltage input range Depends on

Max. rated current

5.0A[Use the powtotal current exceed the mis supplied (epower is turn

Insulation resistance10MΩ betweand the grouresistance te

External connection method

Supplies pow3 points (M3 CommunicatCompatible wConnector (w

Currentconsumptionin CC-Link/LT

system

Total currentconsumption ofeach module in

CC-Link/LT system

=

0.1

0.1(0'4")

1.0(3'3")

10(32'10")

100(328'1")

560(1837'3")

Max

imum

cab

le le

ngth

[m(in

ches

)]

Curre

1000(3280'10")

generation of conductive substances inle is used. The degree of contamination

is caused by generation of only non-

rary conduction may be caused by

d per CC-Link/LT system. only one power adapter, the following

ot satisfied, use of two or more power

adapter is 5A, therefore, total current ent to or less than 5 A.able status, the voltage drop should be

each module connected to the power voltage subtracted by the voltage drop an 20.4 V.

methodlation

-Link/LT supply the power for I/O via the

ion manual of each remote I/O module.

the simplified graph or the calculationbient temperature: 20°C)

graph

within the range shown in the graph

Specification

the connected model (28.8V DC max.).

er adapter in the range in which the consumption of each unit does not aximum rated current while the power xcept the period immediately after the ed on).]

en the external terminals as a whole nd terminal by 500V DC insulation ster

er from outside to power adapter:screws) on terminal blockion line/module power supply moduleith flat cable dedicated to CC-Link/LTith 4 pins) dedicated to CC-Link/LT × 2

Total current consumptionof I/O equipment (suchas sensors) (to whichpower is supplied via

communication cable)*1

+ ≤ 5A

1.0 10

nt consumption [A]

2) Selection based on the calculation

*1 Some remote I/O modules for CC-Lcable dedicated to CC-Link/LT.For the details, refer to the instruction

The simplified graph and the calccalculations may not be accurate and the number of used connectorsIf the driving voltage (20.4V) camodule, add another power adapte

5. InstallationThe power adapter can be installed to Each installation procedure is describe

5.1 Installation directionDo not install the power adapter on thevertical direction. If the power adapter direction, its temperature may rise.Make sure to install the power adapter

5.2 Installation to DIN railAlign the upper DIN rail installation gro1), and press the power adapter in thaWhen removing the power adapter, pDIN rail 3), then remove the power ada

5.3 Direct installationScrew-tighten the power adapter by lower mounting holes (two holes in all)Install the module so that the clearancfor each module.

5.4 Crimp-style terminalFor the I/O wiring, use crimp-style term

Voltagedrop (V)

Maximumdistance (m)

+ Constant: 11

Co: = ×

Maximumdistance

Total currentconsumption

Furthest station

Total currentconsumption of eacmodule in CC-Link/

system

Applicable DIN rail

TH35-7.5Fe and T

1)

Installation

2)

Applicable screwM4 × 0.7mm(0.03"(Tightening torque

6.2 mm (0.24" )or less

Terminal

Terminal screwCrimp-styleterminal

When wiring one cable to one terminal

φ 3.2 (0.13"

formula

ink/LT supply the power for I/O via the flat

manual of each remote I/O module.

ulation formula concerning voltage dropdepending on the ambient temperature dedicated to CC-Link/LT.

nnot be assured in a used remote I/Or.

a DIN rail or directly installed with screws.d below.

floor surface, the ceiling surface or in theis installed on such a surface or in such a

on the wall horizontally.

ove in the power adapter with the DIN railt status 2).ull downward the hook for installation topter 4)

tightening M4 screws to the upper and provided in the power adapter.e of 1 to 2mm (0.04" to 0.08") is assured

inals of the following dimensions.

nstant0.06 ≤ 3.6V× Total current

consumption (A)

from the power adapter

hLT +

Total current consumption of I/Oequipment (such as sensors)

(to which power is supplied viacommunication cable)*1

H35-7.5AI

Removal

3)

4)

) × 16mm(0.63") or more range: 0.78 to 1.08 N⋅m)

6.2 mm (0.24" )or less

Terminal screwCrimp-styleterminal

When wiring two cables to one terminal

Terminal

) φ 3.2 (0.13")

• Tighten the terminal screws (M3 scretightening torque of 0.42 to 0.58 N⋅mtorque outside the above-mentioned circuit, equipment failures, or malfunc

6. Power Wiring

• The external power supply is to be pr

• Use a proper external power supply consumption and total initial current o(such as sensors) connected to the p

7. Outside Dimensions

Applicable crimp-style terminal

• RAV1.25-3• V1.25-3 (manufa• 1.25-3 and TG1.

(manufactured b

Applicable wire size

0.3 to 1.25 mm2

Connector forCC-Link/LTinterface - -

DA

- -DB

Terminal block for power adapter

External power supply24V DC, 5A or less

Grounding(100Ω or less)

LINK

+- 24G

+24V

Power adapter

66(2.60")

85(3

.35")

5(0

.20")

2 - φ4.5(0.18") mountinghole (M4 mounting screw)

75(2

.96")

± 0

.2(0

.01")

ws) on the terminal block with a . Do not tighten terminal screws with a range. Failure to do so may cause short tions.

ovided by the user.

with consideration for total current f remote I/O modules and I/O equipment ower adapter.

ctured by JST Mfg. Co., Ltd.)25-3y NICHIFU Co., Ltd.)

Internalcircuit

Connector forCC-Link/LT interface

+24VDA

24GDB

LINK/POWER

90(3.55")

10(0.40")

43(1

.70")

Center of DIN rail

Mass (Weight):

Approx. 0.26kg (0.58lbs)

Unit: mm(inches)

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUC

When exported from Japan, this manual doesTrade and Industry for service transaction per

This manual confers no industrial properdoes it confer any patent licenses. Mitsuresponsible for any problems involving ina result of using the contents noted in th

WarrantyExclusion of loss in opportunity and secoRegardless of the gratis warranty term, Mit(1) Damages caused by any cause found(2) Loss in opportunity, lost profits incurred (3) Special damages and secondary damag for accidents, and compensation for dam(4) Replacement by the user, maintenanc other tasks.

• This product has been manufactured asindustries, and has not been designed device or system used in purposes rela

• Before using the product for special purpaerospace, medicine or passenger move

• This product has been manufactured unwhen installing the product where majoproduct fails, install appropriate backup

For safe use

Country/Region Sales office/TelUSA MITSUBISHI ELECTRIC AUTOMATION, IN

500 Corporate Woods Parkway, Vernon HiIL 60061, U.S.A.Tel : +1-847-478-2100/+1-847-478-2500 (N

Brazil MITSUBISHI ELECTRIC DO BRASIL COMERCIO E SERVICOS LTDA. Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brazil Tel : +55-11-4689-3000

Germany MITSUBISHI ELECTRIC EUROPE B.V. – German BranchMitsubishi-Electric-Platz 1, 40882 Ratingen, GermanyTel : +49-2102-486-0

UK MITSUBISHI ELECTRIC EUROPE B.V. UK BrTravellers Lane, Hatfield, Hertfordshire, AL10 8XB, UKTel : +44-1707-28-8780

Italy MITSUBISHI ELECTRIC EUROPE B.V. – Italian BranchCentro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, 20864 Agrate Brianza (MB)Tel : +39-039-60531/+39-039-6053-342

Spain MITSUBISHI ELECTRIC EUROPE, B.V. – Spanish BranchCarretera de Rubi 76-80-AC.420, E-08190Sant Cugat del Valles (Barcelona), Spain Tel : +34-935-65-3131/+34-935-65-2236

France MITSUBISHI ELECTRIC EUROPE B.V. – French Branch25, Boulevard des Bouvets, 92741 Nanterre Cedex, FranceTel : +33-1-55-68-55-68

Czech Republic MITSUBISHI ELECTRIC EUROPE B.V. Czech BranchAvenir Business Park, Radicka 751/113e, 158 00 Praha5, Czech RepublicTel : +420-251-551-470

Poland Mitsubishi Electric Europe B.V. Polish Branul. Krakowska 50, 32-083 Balice, PolandTel : +48-12-347-65-00

LINK/POWER connector:Executes communication, and susystem.

3. Specifications1) General specifications

*1 The criterion is shown in IEC6113

*2 The module cannot be used in atmospheric pressure which can bIf the module is used in such an en

*3 It indicates in which wiring aremechanical module inside the connected.The category ΙΙ applies, for exasupplied from a fixed facility.The surge-resistant voltage of eq2,500V.

Item

Ambient working temperature

0 to 55°C (3

Ambient storage temperature

-25 to 75°C

Ambient operating humidity

5 to 95%RHallowed.

Ambient storage humidity

5 to 95%RHallowed.

Vibration resistance (*1)

Intermittent v

Frequency

10 to 57Hz

57 to 150Hz

Continuous v

Frequency

10 to 57Hz

57 to 150Hz

Impact resistance (*1) 147 m/s2, 3

Operating atmosphere

Corrosive ga

Operating altitude 2,000m(656

Installation place Inside contro

Over-voltage category

ΙΙ or less (*3

Degree of contamination

2 or less (*4

Note: This symbol mark

含有有害6物质的名称,含有量,含

 本产品中所含有的有害6物质的所示。

产品中有害物质

本表格依据SJ/T 11364的规定编制

:表示该有害物质在该部件所有均 规定的限量要求以下。

×:表示该有害物质至少在该部件的 26572规定的限量要求。

部件名称 铅(Pb)

汞(Hg)

可编程控制器

外壳

印刷基板

×

「电器电子产品有害物质限制使

基于中国标准法的参考规格:GB/T

pplies the power to the CC-Link/LT

1-2.

an environment pressurized above thee generated around the altitude of 0 m.vironment, it may fail.a from the public wiring net to the

site the equipment is assumed to be

mple, to equipment whose power is

uipment whose rating is up to 300V is

Specification

2 to 131°F)

(-13 to 167°F)

: Dew condensation shall not be

: Dew condensation shall not be

ibration is presentNumber of sweep times

Acceleration Half amplitude

10 times in each of X, Y and Z directions (80 min)

− 0.075mm

9.8m/s2 −ibration is present

Acceleration Half amplitude

− 0.035mm

4.9m/s2 −times in each of X, Y and Z directions

s should not be present.

1'8") or less (*2)

l panel

)

)

SideA

Side

B

JAPANESE

SideB ENGLISH

SAFETY PRECAUTIONS(Read these precautions before using)

Please read this manual carefully and pay special attention to safely in orderto handle this product properly. Also pay careful attention to safely and handlethe module properly.These precautions apply only to Mitsubishi equipment. Refer to the user’smanual of the CPU module to use for a description of the PLC system safetyprecautions.These SAFETY PRECAUTIONS classify the safety precautions into twocategories: "WARNING" and "CAUTION".

Depending on circumstances, procedures indicated by may alsobe linked to serious results.In any case, it is important to follow the directions for usage.Store this manual in a safe place so that you can take it out and read itwhenever necessary. Always forward it to the end user.[DESIGN PRECAUTIONS]

[INSTALLATION PRECAUTIONS]

[WIRING PRECAUTIONS]

Procedures which may lead to a dangerous condition and cause death or serious injury if not carried out properly.

Procedures which may lead to a dangerous condition and cause superficial to medium injury, or physical damage only, if not carried out properly.

• Depending on a failure in the remote I/O module, the output may become the ON or OFF status. For output signals which can lead to a severe accident, install a circuit monitoring them outside the module.

• Do not bind the control cable and the flat cable dedicated to CC-Link/LT together with the main circuit and the power cable. Keep such cables far from the main circuit and the power cable. Assure a distance of 100mm (3.94") or more. Otherwise, malfunction may be caused by noise.

• Use the power adapter without applying any force on the connector for CC-Link/LT interface and the flat cable dedicated to CC-Link/LT.Otherwise, such cables may be broken or fail.

• Use the power adapter within an environment described by the general specifications in this manual.If the power adapter is used in any environment outside the range for the general specifications, electrical shock, fire, malfunction, product damage or product deterioration may occur.

• Do not directly touch the conductive area of the power adapter.Malfunction or damage of the power adapter may be caused by such touching.

• Securely fix the power adapter with DIN rail or mounting screws. Securely tighten the mounting screws within the specified torque range.If the screws are insufficiently tightened, the power adapter may drop, short-circuit or malfunction.If the screws are excessively tightened, the screws may be damaged, and the power adapter may drop or short-circuit.

• Install the power adapter on to a flat surface.If the mounting surface is concave and/or convex, and if excessive force is applied on the PC board, nonconformity may occur.

• Make sure to shut down all phases of the power supply outside the module before starting the installation or wiring work. If all phases are not shut down, electrical shock or product damage may be caused.

Thank you very much for purchasing this product.

CL1PAD1Power Adapter Model

Please read this manual thoroughly before starting to use the product and handle the product properly.

User’s ManualMODEL CL1PAD1MANUAL Number JY997D04601GDate March 2018

• Confirm the rated voltage and the terminal arrangement of the power adapter, then correctly wire the power adapter.If a power supply not conforming to the specification rating is connected or the power adapter is wired incorrectly, fire, failure or malfunction may occur.

• Tighten the terminal screws within the specified torque range.If the terminal screws are insufficiently tightened, fire or malfunction may occur.

[STARTING AND MAINTENANCE PRECAUTIONS]

[DISPOSAL PRECAUTIONS]

[TRANSPORTATION AND MAINTENANCE PRECAUTIONS]

Notification of CE markingThis notification does not guarantee that an entire mechanical module producedin accordance with the contents of the notification comply with the followingstandards. Compliance to EMC standards of the entire mechanical moduleshould be checked by the user / manufacturer.AttentionThis product is designed for use in industrial applications.

If the terminal screws are excessively tightened, the screws may be damaged, and the module may short-circuit, equipment failures, or malfunction.

• Make sure that foreign objects such as cutting and wire chips do not enter the power adapter.Fire, failure or malfunction may be caused by the foreign objects.

• Attach a warning label (hazard symbol 417-IEC-5036) concerning electric shock to the panel.

• Do not touch the terminals while the power is being supplied.Electrical shock or malfunction may be caused by such touching.

• Shut down all phases of the power supply outside the power adapter before cleaning or tightening the terminal screws.If all phases are not shut down, the power adapter may fail or malfunction.

• Do not disassemble or modify the power adapter.Failure, malfunction, injury or fire may be caused by disassembly or modification.

• The power adapter case is made of resin. Do not drop it. Do not apply strong impact to it.The power adapter may be damaged by dropping or strong impact.

• Shut down all phases of the power supply outside the power adapter before attaching or removing the power adapter to/from the panel.If all phases are not shut down, the power adapter may fail or malfunction.

• When disposing of the product, treat it as an industrial waste.

• During transportation avoid any impact as the module is a precision instrument. Doing so could cause trouble in the module.

• If is necessary to check the operation of module after transportation, in case of any impact damage.

Standards with which this product com

plies Type : Programmable Controller (Open Type Equipment)Models : Products manufactured:

from November 1st, 2002 to April 30th, 2006 are compliant with EN61000-6-4 and EN61131-2:1994+A11:1996+A12:2000after May 1st, 2006 are compliant with EN61131-2:2007

Electromagnetic Compatibility Standards (EMC) Remark

EN61000-6-4:2001Electromagnetic compatibility-Generic standards - Emission standard for Industrial environment

Compliance with all relevant aspects of the standard.(Radiated Emissions and Mains Terminal Voltage Emissions)

EN61131-2:1994/A11:1996/A12:2000Programmable controllers -Equipment requirements and tests

Compliance with all relevant aspects of the standard. • Radiated electromagnetic field• Fast transient burst• Electrostatic discharge• Damped oscillatory wave

EN61131-2: 2007Programmable controllers -Equipment requirements and tests

Compliance with all relevant aspects of the standard.EMI• Radiated Emission• Conducted EmissionEMS• Radiated electromagnetic field• Fast transient burst• Electrostatic discharge• High-energy surge• Voltage drops and interruptions• Conducted RF• Power frequency magnetic field

For more details please contact the local Mitsubishi Electric sales site.• Notes for compliance to EMC LVD regulation.

It is necessary to install the CL1 series module in a shielded metal control panel.

• Use this product in Zone A*1 as defined in EN61131-2.

*1 Zone defined in EN61131-2Separation defined in EN61131-2 for EMC LVD regulation decideddepending on condition in industrial setting.Zone C = Factory mains which is isolated from public mains by dedicated

transformers.Zone B = Dedicated power distribution which is protected by secondary

surge protection. (300V or less in the rated voltage isassumed.)

Zone A = Local power distribution which is isolated from dedicated powerdistribution by AC/DC converters, isolation transformers, etc. (120V or less in the rated voltage is assumed.)

• When the following models use the CC-Link/LT power adapter model (CL1PAD1), a power line connecting to the external power supply terminal of the CL1PAD must be 30m(98’5’’) or less.- CL2AD4-B

- CL2DA2-B

1. Outline of ProductThis product is a power adapter connected to CC-Link/LT.This product supplies 24V DC power from an external power supply to the CC-Link/LT system.At least one power adapter is required per CC-Link/LT system.

2. Name of Each Part

2.1 Name of each part and assignmentDIN rail installation groovePower terminal

2-φ4.5 mounting hole(M4 mounting screw)

Status indicator LED

LINK connector

LINK/POWER connector

Terminal arrangement

24

G

+2

4V

Name DescriptionStatus indicator LED

POWER Lit while the power is supplied

LINK DB For communication

Interface

connector DA Fo

LINK/POWER connector

24G PoDB FoDA Fo+24V Po

Power terminal

+24VSuadInp(d

Ra(Uure

24G

r communicationwer supply for communication (-)r communicationr communicationwer supply for communication (+)pplies power from outside to power apter.ut voltage: 28.8V DC or lessepending on connected model)ted input current: 5.0 Ase a proper external power supply

nder consideration of initial current of mote I/O modules.)

2.2 Handling of LINK connector

1) LINK connector2) LINK/POWER connector

LINK connector:Executes only communication (does noUsed when two or more power adapsystem.

Master module

Power adapter Po

Externalpowersupply

1)

2)

and LINK/POWER connector

t supply power).ters are used in the CC-Link/LT

COMM.

1

COMM.

1

wer adapter

Externalpowersupply

1)

2)

Specifications subject to change without notice.

HI, CHIYODA-KU, TOKYO 100-8310, JAPAN

not require application to the Ministry of Economy, mission.

ty rights or any rights of any other kind, nor bishi Electric Corporation cannot be held dustrial property rights which may occur as

is manual.

ndary loss from warranty liabilitysubishi shall not be liable for compensation to: not to be the responsibility of Mitsubishi.to the user by Failures of Mitsubishi products.es whether foreseeable or not, compensation

ages to products other than Mitsubishi products.e of on-site equipment, start-up test run and

a general-purpose part for generalor manufactured to be incorporated in a ted to human life.oses such as nuclear power, electric power, ment vehicles, consult with Mitsubishi Electric. der strict quality control. However

r accidents or losses could occur if the or failsafe functions in the system.

C.lls,

C)

anch

, Italy

ch

Country/Region Sales office/TelRussia

China MITSUBISHI ELECTRIC AUTOMATION (CHINA) LTD.Mitsubishi Electric Automation Center, No.1386 Hongqiao Road, Shanghai, ChinaTel : +86-21-2322-3030

Taiwan SETSUYO ENTERPRISE CO., LTD.6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan, R.O.C.Tel : +886-2-2299-2499

Korea MITSUBISHI ELECTRIC AUTOMATION KOREA CO., LTD.7F~9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul, 07528, KoreaTel : +82-2-3660-9530

Singapore MITSUBISHI ELECTRIC ASIA PTE. LTD, 307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943 Tel : +65-6473-2308

Thailand Mitsubishi Electric Factory Automation (Thailand) Co., Ltd.12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, ThailandTel : +66-2682-6522~31

Indonesia PT. Mitsubishi Electric IndonesiaGedung Jaya 11th Floor, JL. MH. ThamrinNo.12, Jakarta Pusat 10340, IndonesiaTel : +62-21-3192-6461

India Mitsubishi Electric India Pvt. Ltd. Gurgaon Head Office2nd Floor, Tower A & B, Cyber Greens, DLF Cyber City, DLF Phase - III, Gurgaon - 122002, Haryana, IndiaTel : +91-124-4630300

Australia MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD.348 Victoria Road PO BOX11, Rydalmere, N.S.W 2116, Australia Tel : + 61-2-9684-7777

Mitsubishi Electric (Russia) LLC52, bld. 1, Kosmodamianskaya emb., 115054 Moscow, RussiaTel : +7-495-721-2070

is for China only.

有部品名称,含有量,含有部品如下表

的名称及含量

质材料中的含量均在GB/T 26572

某一均质材料中的含量超出GB/T

有害物质

镉(Cd)

六价铬(Cr(VI))

多溴联苯(PBB)

多溴二苯醚(PBDE)

用标识要求」的表示方式

15969.2

Page 2: CL1PAD1 Power Adapter Model User's Manual€¦ · The power adapter may be damaged by dropping or strong impact. • Shut down all phases of the power supply outside the power adapter

Specifications subject to change without notice.

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.

This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.

WarrantyExclusion of loss in opportunity and secondary loss from warranty liabilityRegardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.(3) Special damages and secondary damages whether foreseeable or not, compensation for accidents, and compensation for damages to products other than Mitsubishi products.(4) Replacement by the user, maintenance of on-site equipment, start-up test run and other tasks.

• This product has been manufactured as a general-purpose part for generalindustries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.

• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric.

• This product has been manufactured under strict quality control. Howeverwhen installing the product where major accidents or losses could occur if theproduct fails, install appropriate backup or failsafe functions in the system.

For safe use

Country/Region Sales office/TelUSA MITSUBISHI ELECTRIC AUTOMATION, INC.

500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A.Tel : +1-847-478-2100/+1-847-478-2500 (NC)

Brazil MITSUBISHI ELECTRIC DO BRASIL COMERCIO E SERVICOS LTDA. Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brazil Tel : +55-11-4689-3000

Germany MITSUBISHI ELECTRIC EUROPE B.V. – German BranchMitsubishi-Electric-Platz 1, 40882 Ratingen, GermanyTel : +49-2102-486-0

UK MITSUBISHI ELECTRIC EUROPE B.V. UK BranchTravellers Lane, Hatfield, Hertfordshire, AL10 8XB, UKTel : +44-1707-28-8780

Italy MITSUBISHI ELECTRIC EUROPE B.V. – Italian BranchCentro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, 20864 Agrate Brianza (MB), ItalyTel : +39-039-60531/+39-039-6053-342

Spain MITSUBISHI ELECTRIC EUROPE, B.V. – Spanish BranchCarretera de Rubi 76-80-AC.420, E-08190 Sant Cugat del Valles (Barcelona), Spain Tel : +34-935-65-3131/+34-935-65-2236

France MITSUBISHI ELECTRIC EUROPE B.V. – French Branch25, Boulevard des Bouvets, 92741 Nanterre Cedex, FranceTel : +33-1-55-68-55-68

Czech Republic MITSUBISHI ELECTRIC EUROPE B.V. Czech BranchAvenir Business Park, Radicka 751/113e, 158 00 Praha5, Czech RepublicTel : +420-251-551-470

Poland Mitsubishi Electric Europe B.V. Polish Branchul. Krakowska 50, 32-083 Balice, PolandTel : +48-12-347-65-00

Country/Region Sales office/TelRussia

China MITSUBISHI ELECTRIC AUTOMATION (CHINA) LTD.Mitsubishi Electric Automation Center, No.1386 Hongqiao Road, Shanghai, ChinaTel : +86-21-2322-3030

Taiwan SETSUYO ENTERPRISE CO., LTD.6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan, R.O.C.Tel : +886-2-2299-2499

Korea MITSUBISHI ELECTRIC AUTOMATION KOREA CO., LTD.7F~9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul, 07528, KoreaTel : +82-2-3660-9530

Singapore MITSUBISHI ELECTRIC ASIA PTE. LTD, 307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943 Tel : +65-6473-2308

Thailand Mitsubishi Electric Factory Automation (Thailand) Co., Ltd.12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, ThailandTel : +66-2682-6522~31

Indonesia PT. Mitsubishi Electric IndonesiaGedung Jaya 11th Floor, JL. MH. ThamrinNo.12, Jakarta Pusat 10340, IndonesiaTel : +62-21-3192-6461

India Mitsubishi Electric India Pvt. Ltd. Gurgaon Head Office2nd Floor, Tower A & B, Cyber Greens, DLF Cyber City, DLF Phase - III, Gurgaon - 122002, Haryana, IndiaTel : +91-124-4630300

Australia MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD.348 Victoria Road PO BOX11, Rydalmere, N.S.W 2116, Australia Tel : + 61-2-9684-7777

Mitsubishi Electric (Russia) LLC52, bld. 1, Kosmodamianskaya emb., 115054 Moscow, RussiaTel : +7-495-721-2070

SideA

Side

B

JAPANESE

SideB ENGLISH

SAFETY PRECAUTIONS(Read these precautions before using)

Please read this manual carefully and pay special attention to safely in orderto handle this product properly. Also pay careful attention to safely and handlethe module properly.These precautions apply only to Mitsubishi equipment. Refer to the user’smanual of the CPU module to use for a description of the PLC system safetyprecautions.These SAFETY PRECAUTIONS classify the safety precautions into twocategories: "WARNING" and "CAUTION".

Depending on circumstances, procedures indicated by may alsobe linked to serious results.In any case, it is important to follow the directions for usage.Store this manual in a safe place so that you can take it out and read itwhenever necessary. Always forward it to the end user.[DESIGN PRECAUTIONS]

[INSTALLATION PRECAUTIONS]

[WIRING PRECAUTIONS]

Procedures which may lead to a dangerous condition and cause death or serious injury if not carried out properly.

Procedures which may lead to a dangerous condition and cause superficial to medium injury, or physical damage only, if not carried out properly.

• Depending on a failure in the remote I/O module, the output may become the ON or OFF status. For output signals which can lead to a severe accident, install a circuit monitoring them outside the module.

• Do not bind the control cable and the flat cable dedicated to CC-Link/LT together with the main circuit and the power cable. Keep such cables far from the main circuit and the power cable. Assure a distance of 100mm (3.94") or more. Otherwise, malfunction may be caused by noise.

• Use the power adapter without applying any force on the connector for CC-Link/LT interface and the flat cable dedicated to CC-Link/LT.Otherwise, such cables may be broken or fail.

• Use the power adapter within an environment described by the general specifications in this manual.If the power adapter is used in any environment outside the range for the general specifications, electrical shock, fire, malfunction, product damage or product deterioration may occur.

• Do not directly touch the conductive area of the power adapter.Malfunction or damage of the power adapter may be caused by such touching.

• Securely fix the power adapter with DIN rail or mounting screws. Securely tighten the mounting screws within the specified torque range.If the screws are insufficiently tightened, the power adapter may drop, short-circuit or malfunction.If the screws are excessively tightened, the screws may be damaged, and the power adapter may drop or short-circuit.

• Install the power adapter on to a flat surface.If the mounting surface is concave and/or convex, and if excessive force is applied on the PC board, nonconformity may occur.

• Make sure to shut down all phases of the power supply outside the module before starting the installation or wiring work. If all phases are not shut down, electrical shock or product damage may be caused.

[STARTING AND MAINTENANCE PRECAUTIONS]

[DISPOSAL PRECAUTIONS]

[TRANSPORTATION AND MAINTENANCE PRECAUTIONS]

Notification of CE markingThis notification does not guarantee that an entire mechanical module producedin accordance with the contents of the notification comply with the followingstandards. Compliance to EMC standards of the entire mechanical moduleshould be checked by the user / manufacturer.AttentionThis product is designed for use in industrial applications.

Standards with which this product compliesType : Programmable Controller (Open Type Equipment)Models : Products manufactured:

from November 1st, 2002 to April 30th, 2006 are compliant with EN61000-6-4 and EN61131-2:1994+A11:1996+A12:2000after May 1st, 2006 are compliant with EN61131-2:2007

• Confirm the rated voltage and the terminal arrangement of the power adapter, then correctly wire the power adapter.If a power supply not conforming to the specification rating is connected or the power adapter is wired incorrectly, fire, failure or malfunction may occur.

• Tighten the terminal screws within the specified torque range.If the terminal screws are insufficiently tightened, fire or malfunction may occur.If the terminal screws are excessively tightened, the screws may be damaged, and the module may short-circuit, equipment failures, or malfunction.

• Make sure that foreign objects such as cutting and wire chips do not enter the power adapter.Fire, failure or malfunction may be caused by the foreign objects.

• Attach a warning label (hazard symbol 417-IEC-5036) concerning electric shock to the panel.

• Do not touch the terminals while the power is being supplied.Electrical shock or malfunction may be caused by such touching.

• Shut down all phases of the power supply outside the power adapter before cleaning or tightening the terminal screws.If all phases are not shut down, the power adapter may fail or malfunction.

• Do not disassemble or modify the power adapter.Failure, malfunction, injury or fire may be caused by disassembly or modification.

• The power adapter case is made of resin. Do not drop it. Do not apply strong impact to it.The power adapter may be damaged by dropping or strong impact.

• Shut down all phases of the power supply outside the power adapter before attaching or removing the power adapter to/from the panel.If all phases are not shut down, the power adapter may fail or malfunction.

• When disposing of the product, treat it as an industrial waste.

• During transportation avoid any impact as the module is a precision instrument. Doing so could cause trouble in the module.

• If is necessary to check the operation of module after transportation, in case of any impact damage.

Electromagnetic Compatibility Standards (EMC) Remark

EN61000-6-4:2001Electromagnetic compatibility-Generic standards - Emission standard for Industrial environment

Compliance with all relevant aspects of the standard.(Radiated Emissions and Mains Terminal Voltage Emissions)

EN61131-2:1994/A11:1996/A12:2000Programmable controllers -Equipment requirements and tests

Compliance with all relevant aspects of the standard. • Radiated electromagnetic field• Fast transient burst• Electrostatic discharge• Damped oscillatory wave

EN61131-2: 2007Programmable controllers -Equipment requirements and tests

Compliance with all relevant aspects of the standard.EMI• Radiated Emission• Conducted EmissionEMS• Radiated electromagnetic field• Fast transient burst• Electrostatic discharge• High-energy surge• Voltage drops and interruptions• Conducted RF• Power frequency magnetic field

For more details please contact the local Mitsubishi Electric sales site.• Notes for compliance to EMC LVD regulation.

It is necessary to install the CL1 series module in a shielded metal control panel.

• Use this product in Zone A*1 as defined in EN61131-2.

*1 Zone defined in EN61131-2Separation defined in EN61131-2 for EMC LVD regulation decideddepending on condition in industrial setting.Zone C = Factory mains which is isolated from public mains by dedicated

transformers.Zone B = Dedicated power distribution which is protected by secondary

surge protection. (300V or less in the rated voltage isassumed.)

Zone A = Local power distribution which is isolated from dedicated powerdistribution by AC/DC converters, isolation transformers, etc. (120V or less in the rated voltage is assumed.)

• When the following models use the CC-Link/LT power adapter model (CL1PAD1), a power line connecting to the external power supply terminal of the CL1PAD must be 30m(98’5’’) or less.- CL2AD4-B

- CL2DA2-B

1. Outline of ProductThis product is a power adapter connected to CC-Link/LT.This product supplies 24V DC power from an external power supply to the CC-Link/LT system.At least one power adapter is required per CC-Link/LT system.

2. Name of Each Part

2.1 Name of each part and assignmentDIN rail installation groovePower terminal

2-φ4.5 mounting hole(M4 mounting screw)

Status indicator LED

LINK connector

LINK/POWER connector

Terminal arrangement

24

G

+2

4V

Name DescriptionStatus indicator LED

POWER Lit while the power is supplied

Interface

LINK connector

DB For communicationDA For communication

LINK/POWER connector

24G Power supply for communication (-)DB For communicationDA For communication+24V Power supply for communication (+)

Power terminal

+24VSupplies power from outside to power adapter.Input voltage: 28.8V DC or less(depending on connected model)

Rated input current: 5.0 A(Use a proper external power supply under consideration of initial current of remote I/O modules.)

24G

2.2 Handling of LINK connector and LINK/POWER connector

1) LINK connector2) LINK/POWER connector

LINK connector:Executes only communication (does not supply power).Used when two or more power adapters are used in the CC-Link/LTsystem.

LINK/POWER connector:Executes communication, and supplies the power to the CC-Link/LTsystem.

3. Specifications1) General specifications

*1 The criterion is shown in IEC61131-2.

*2 The module cannot be used in an environment pressurized above theatmospheric pressure which can be generated around the altitude of 0 m.If the module is used in such an environment, it may fail.

*3 It indicates in which wiring area from the public wiring net to themechanical module inside the site the equipment is assumed to beconnected.The category ΙΙ applies, for example, to equipment whose power issupplied from a fixed facility.The surge-resistant voltage of equipment whose rating is up to 300V is2,500V.

COMM.

1

COMM.

1

Master module

Power adapter Power adapter

Externalpowersupply

Externalpowersupply

1)

2)

1)

2)

Item Specification

Ambient working temperature

0 to 55°C (32 to 131°F)

Ambient storage temperature

-25 to 75°C (-13 to 167°F)

Ambient operating humidity

5 to 95%RH: Dew condensation shall not be allowed.

Ambient storage humidity

5 to 95%RH: Dew condensation shall not be allowed.

Vibration resistance (*1)

Intermittent vibration is presentNumber of sweep times

Frequency Acceleration Half amplitude

10 times in each of X, Y and Z directions (80 min)

10 to 57Hz − 0.075mm

57 to 150Hz 9.8m/s2 −Continuous vibration is present

Frequency Acceleration Half amplitude

10 to 57Hz − 0.035mm

57 to 150Hz 4.9m/s2 −Impact resistance (*1) 147 m/s2, 3 times in each of X, Y and Z directions

Operating atmosphere

Corrosive gas should not be present.

Operating altitude 2,000m(6561'8") or less (*2)

Installation place Inside control panel

Over-voltage category

ΙΙ or less (*3)

Degree of contamination

2 or less (*4)

*4 This index indicates the degree of generation of conductive substances inthe environment in which the module is used. The degree of contamination2 indicates that contamination is caused by generation of only non-conductive substances.In this degree, however, temporary conduction may be caused byaccidental condensation.

2) Performance specifications

4. Construction CautionsInstallation of power adaptersAt least one power adapter is required per CC-Link/LT system.When constructing the system using only one power adapter, the followingthree conditions should be satisfied.If the following two conditions are not satisfied, use of two or more poweradapters in constructing the system.• The current capacity of the power adapter is 5A, therefore, total current

consumption should be an equivalent to or less than 5 A.• In order to operate the system in stable status, the voltage drop should be

equivalent to or less than 3.6 V.• The minimum operating voltage of each module connected to the power

adapter is 20.4 V, therefore, supply voltage subtracted by the voltage drop should be equivalent to or more than 20.4 V.

4.1 System power calculation method4.1.1 Current consumption calculation

*5 Some remote I/O modules for CC-Link/LT supply the power for I/O via theflat cable dedicated to CC-Link/LT.For the details, refer to the instruction manual of each remote I/O module.

4.1.2 Voltage dropCalculate the voltage drop based on the simplified graph or the calculationformula. (supply voltage: 24V DC, ambient temperature: 20°C)1) Selection based on the simplified graph

One power adapter is allowed within the range shown in the graphabove.

Item Specification

Voltage input range Depends on the connected model (28.8V DC max.).

Max. rated current

5.0A[Use the power adapter in the range in which the total current consumption of each unit does not exceed the maximum rated current while the power is supplied (except the period immediately after the power is turned on).]

Insulation resistance10MΩ between the external terminals as a whole and the ground terminal by 500V DC insulation resistance tester

External connection method

Supplies power from outside to power adapter:3 points (M3 screws) on terminal blockCommunication line/module power supply moduleCompatible with flat cable dedicated to CC-Link/LTConnector (with 4 pins) dedicated to CC-Link/LT × 2

Currentconsumptionin CC-Link/LT

system

Total currentconsumption ofeach module in

CC-Link/LT system

Total current consumptionof I/O equipment (suchas sensors) (to whichpower is supplied via

communication cable)*1

= + ≤ 5A

0.1

0.1(0'4")

1.0(3'3")

10(32'10")

100(328'1")

560(1837'3")

1.0 10

Max

imum

cab

le le

ngth

[m(in

ches

)]

Current consumption [A]

1000(3280'10")

2) Selection based on the calculation formula

*1 Some remote I/O modules for CC-Link/LT supply the power for I/O via the flatcable dedicated to CC-Link/LT.For the details, refer to the instruction manual of each remote I/O module.

The simplified graph and the calculation formula concerning voltage dropcalculations may not be accurate depending on the ambient temperatureand the number of used connectors dedicated to CC-Link/LT.If the driving voltage (20.4V) cannot be assured in a used remote I/Omodule, add another power adapter.

5. InstallationThe power adapter can be installed to a DIN rail or directly installed with screws.Each installation procedure is described below.

5.1 Installation directionDo not install the power adapter on the floor surface, the ceiling surface or in thevertical direction. If the power adapter is installed on such a surface or in such adirection, its temperature may rise.Make sure to install the power adapter on the wall horizontally.

5.2 Installation to DIN railAlign the upper DIN rail installation groove in the power adapter with the DIN rail1), and press the power adapter in that status 2).When removing the power adapter, pull downward the hook for installation toDIN rail 3), then remove the power adapter 4)

5.3 Direct installationScrew-tighten the power adapter by tightening M4 screws to the upper andlower mounting holes (two holes in all) provided in the power adapter.Install the module so that the clearance of 1 to 2mm (0.04" to 0.08") is assuredfor each module.

5.4 Crimp-style terminalFor the I/O wiring, use crimp-style terminals of the following dimensions.

Voltagedrop (V)

Maximumdistance (m)

+ Constant: 11

Constant: 0.06= × ≤ 3.6V× Total current

consumption (A)

Maximumdistance

Total currentconsumption

Furthest station from the power adapter

Total currentconsumption of eachmodule in CC-Link/LT

system

+Total current consumption of I/O

equipment (such as sensors)(to which power is supplied via

communication cable)*1

Applicable DIN rail

TH35-7.5Fe and TH35-7.5AI

1)

Installation Removal

2)3)

4)

Applicable screwM4 × 0.7mm(0.03") × 16mm(0.63") or more(Tightening torque range: 0.78 to 1.08 N⋅m)

6.2 mm (0.24" )or less

6.2 mm (0.24" )or less

Terminal

Terminal screwCrimp-styleterminal

Terminal screwCrimp-styleterminal

When wiring one cable to one terminal When wiring two cables to one terminal

Terminal

φ 3.2 (0.13") φ 3.2 (0.13")

• Tighten the terminal screws (M3 screws) on the terminal block with a tightening torque of 0.42 to 0.58 N⋅m. Do not tighten terminal screws with a torque outside the above-mentioned range. Failure to do so may cause short circuit, equipment failures, or malfunctions.

6. Power Wiring

• The external power supply is to be provided by the user.

• Use a proper external power supply with consideration for total current consumption and total initial current of remote I/O modules and I/O equipment (such as sensors) connected to the power adapter.

7. Outside Dimensions

Applicable crimp-style terminal

• RAV1.25-3• V1.25-3 (manufactured by JST Mfg. Co., Ltd.)• 1.25-3 and TG1.25-3

(manufactured by NICHIFU Co., Ltd.)

Applicable wire size

0.3 to 1.25 mm2

Connector forCC-Link/LTinterface - -

DA

- -DB

Internalcircuit

Connector forCC-Link/LT interface

Terminal block for power adapter

External power supply24V DC, 5A or less

Grounding(100Ω or less)

+24VDA

24GDB

LINK LINK/POWER

+- 24G

+24V

Power adapter

66(2.60") 90(3.55")

10(0.40")

85(3

.35")

5(0

.20")

43(1

.70")

2 - φ4.5(0.18") mountinghole (M4 mounting screw)

Center of DIN rail

Mass (Weight):

Approx. 0.26kg (0.58lbs)

75(2

.96")

± 0

.2(0

.01")

Unit: mm(inches)

Thank you very much for purchasing this product.

CL1PAD1Power Adapter Model

Please read this manual thoroughly before starting to use the product and handle the product properly.

User’s ManualMODEL CL1PAD1MANUAL Number JY997D04601GDate March 2018

Note: This symbol mark is for China only.

含有有害6物质的名称,含有量,含有部品

 本产品中所含有的有害6物质的名称,含有量,含有部品如下表所示。

产品中有害物质的名称及含量

本表格依据SJ/T 11364的规定编制。

:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572 规定的限量要求以下。

×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 26572规定的限量要求。

部件名称

有害物质

铅(Pb)

汞(Hg)

镉(Cd)

六价铬(Cr(VI))

多溴联苯(PBB)

多溴二苯醚(PBDE)

可编程控制器

外壳

印刷基板

×

「电器电子产品有害物质限制使用标识要求」的表示方式

基于中国标准法的参考规格:GB/T15969.2

Page 3: CL1PAD1 Power Adapter Model User's Manual€¦ · The power adapter may be damaged by dropping or strong impact. • Shut down all phases of the power supply outside the power adapter

Specifications subject to change without notice.

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.

This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.

WarrantyExclusion of loss in opportunity and secondary loss from warranty liabilityRegardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.(3) Special damages and secondary damages whether foreseeable or not, compensation for accidents, and compensation for damages to products other than Mitsubishi products.(4) Replacement by the user, maintenance of on-site equipment, start-up test run and other tasks.

• This product has been manufactured as a general-purpose part for generalindustries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.

• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric.

• This product has been manufactured under strict quality control. Howeverwhen installing the product where major accidents or losses could occur if theproduct fails, install appropriate backup or failsafe functions in the system.

For safe use

Country/Region Sales office/TelUSA MITSUBISHI ELECTRIC AUTOMATION, INC.

500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A.Tel : +1-847-478-2100/+1-847-478-2500 (NC)

Brazil MITSUBISHI ELECTRIC DO BRASIL COMERCIO E SERVICOS LTDA. Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brazil Tel : +55-11-4689-3000

Germany MITSUBISHI ELECTRIC EUROPE B.V. – German BranchMitsubishi-Electric-Platz 1, 40882 Ratingen, GermanyTel : +49-2102-486-0

UK MITSUBISHI ELECTRIC EUROPE B.V. UK BranchTravellers Lane, Hatfield, Hertfordshire, AL10 8XB, UKTel : +44-1707-28-8780

Italy MITSUBISHI ELECTRIC EUROPE B.V. – Italian BranchCentro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, 20864 Agrate Brianza (MB), ItalyTel : +39-039-60531/+39-039-6053-342

Spain MITSUBISHI ELECTRIC EUROPE, B.V. – Spanish BranchCarretera de Rubi 76-80-AC.420, E-08190 Sant Cugat del Valles (Barcelona), Spain Tel : +34-935-65-3131/+34-935-65-2236

France MITSUBISHI ELECTRIC EUROPE B.V. – French Branch25, Boulevard des Bouvets, 92741 Nanterre Cedex, FranceTel : +33-1-55-68-55-68

Czech Republic MITSUBISHI ELECTRIC EUROPE B.V. Czech BranchAvenir Business Park, Radicka 751/113e, 158 00 Praha5, Czech RepublicTel : +420-251-551-470

Poland Mitsubishi Electric Europe B.V. Polish Branchul. Krakowska 50, 32-083 Balice, PolandTel : +48-12-347-65-00

Country/Region Sales office/TelRussia

China MITSUBISHI ELECTRIC AUTOMATION (CHINA) LTD.Mitsubishi Electric Automation Center, No.1386 Hongqiao Road, Shanghai, ChinaTel : +86-21-2322-3030

Taiwan SETSUYO ENTERPRISE CO., LTD.6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan, R.O.C.Tel : +886-2-2299-2499

Korea MITSUBISHI ELECTRIC AUTOMATION KOREA CO., LTD.7F~9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul, 07528, KoreaTel : +82-2-3660-9530

Singapore MITSUBISHI ELECTRIC ASIA PTE. LTD, 307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943 Tel : +65-6473-2308

Thailand Mitsubishi Electric Factory Automation (Thailand) Co., Ltd.12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, ThailandTel : +66-2682-6522~31

Indonesia PT. Mitsubishi Electric IndonesiaGedung Jaya 11th Floor, JL. MH. ThamrinNo.12, Jakarta Pusat 10340, IndonesiaTel : +62-21-3192-6461

India Mitsubishi Electric India Pvt. Ltd. Gurgaon Head Office2nd Floor, Tower A & B, Cyber Greens, DLF Cyber City, DLF Phase - III, Gurgaon - 122002, Haryana, IndiaTel : +91-124-4630300

Australia MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD.348 Victoria Road PO BOX11, Rydalmere, N.S.W 2116, Australia Tel : + 61-2-9684-7777

Mitsubishi Electric (Russia) LLC52, bld. 1, Kosmodamianskaya emb., 115054 Moscow, RussiaTel : +7-495-721-2070

SideA

Side

B

JAPANESE

SideB ENGLISH

SAFETY PRECAUTIONS(Read these precautions before using)

Please read this manual carefully and pay special attention to safely in orderto handle this product properly. Also pay careful attention to safely and handlethe module properly.These precautions apply only to Mitsubishi equipment. Refer to the user’smanual of the CPU module to use for a description of the PLC system safetyprecautions.These SAFETY PRECAUTIONS classify the safety precautions into twocategories: "WARNING" and "CAUTION".

Depending on circumstances, procedures indicated by may alsobe linked to serious results.In any case, it is important to follow the directions for usage.Store this manual in a safe place so that you can take it out and read itwhenever necessary. Always forward it to the end user.[DESIGN PRECAUTIONS]

[INSTALLATION PRECAUTIONS]

[WIRING PRECAUTIONS]

Procedures which may lead to a dangerous condition and cause death or serious injury if not carried out properly.

Procedures which may lead to a dangerous condition and cause superficial to medium injury, or physical damage only, if not carried out properly.

• Depending on a failure in the remote I/O module, the output may become the ON or OFF status. For output signals which can lead to a severe accident, install a circuit monitoring them outside the module.

• Do not bind the control cable and the flat cable dedicated to CC-Link/LT together with the main circuit and the power cable. Keep such cables far from the main circuit and the power cable. Assure a distance of 100mm (3.94") or more. Otherwise, malfunction may be caused by noise.

• Use the power adapter without applying any force on the connector for CC-Link/LT interface and the flat cable dedicated to CC-Link/LT.Otherwise, such cables may be broken or fail.

• Use the power adapter within an environment described by the general specifications in this manual.If the power adapter is used in any environment outside the range for the general specifications, electrical shock, fire, malfunction, product damage or product deterioration may occur.

• Do not directly touch the conductive area of the power adapter.Malfunction or damage of the power adapter may be caused by such touching.

• Securely fix the power adapter with DIN rail or mounting screws. Securely tighten the mounting screws within the specified torque range.If the screws are insufficiently tightened, the power adapter may drop, short-circuit or malfunction.If the screws are excessively tightened, the screws may be damaged, and the power adapter may drop or short-circuit.

• Install the power adapter on to a flat surface.If the mounting surface is concave and/or convex, and if excessive force is applied on the PC board, nonconformity may occur.

• Make sure to shut down all phases of the power supply outside the module before starting the installation or wiring work. If all phases are not shut down, electrical shock or product damage may be caused.

[STARTING AND MAINTENANCE PRECAUTIONS]

[DISPOSAL PRECAUTIONS]

[TRANSPORTATION AND MAINTENANCE PRECAUTIONS]

Notification of CE markingThis notification does not guarantee that an entire mechanical module producedin accordance with the contents of the notification comply with the followingstandards. Compliance to EMC standards of the entire mechanical moduleshould be checked by the user / manufacturer.AttentionThis product is designed for use in industrial applications.

Standards with which this product compliesType : Programmable Controller (Open Type Equipment)Models : Products manufactured:

from November 1st, 2002 to April 30th, 2006 are compliant with EN61000-6-4 and EN61131-2:1994+A11:1996+A12:2000after May 1st, 2006 are compliant with EN61131-2:2007

• Confirm the rated voltage and the terminal arrangement of the power adapter, then correctly wire the power adapter.If a power supply not conforming to the specification rating is connected or the power adapter is wired incorrectly, fire, failure or malfunction may occur.

• Tighten the terminal screws within the specified torque range.If the terminal screws are insufficiently tightened, fire or malfunction may occur.If the terminal screws are excessively tightened, the screws may be damaged, and the module may short-circuit, equipment failures, or malfunction.

• Make sure that foreign objects such as cutting and wire chips do not enter the power adapter.Fire, failure or malfunction may be caused by the foreign objects.

• Attach a warning label (hazard symbol 417-IEC-5036) concerning electric shock to the panel.

• Do not touch the terminals while the power is being supplied.Electrical shock or malfunction may be caused by such touching.

• Shut down all phases of the power supply outside the power adapter before cleaning or tightening the terminal screws.If all phases are not shut down, the power adapter may fail or malfunction.

• Do not disassemble or modify the power adapter.Failure, malfunction, injury or fire may be caused by disassembly or modification.

• The power adapter case is made of resin. Do not drop it. Do not apply strong impact to it.The power adapter may be damaged by dropping or strong impact.

• Shut down all phases of the power supply outside the power adapter before attaching or removing the power adapter to/from the panel.If all phases are not shut down, the power adapter may fail or malfunction.

• When disposing of the product, treat it as an industrial waste.

• During transportation avoid any impact as the module is a precision instrument. Doing so could cause trouble in the module.

• If is necessary to check the operation of module after transportation, in case of any impact damage.

Electromagnetic Compatibility Standards (EMC) Remark

EN61000-6-4:2001Electromagnetic compatibility-Generic standards - Emission standard for Industrial environment

Compliance with all relevant aspects of the standard.(Radiated Emissions and Mains Terminal Voltage Emissions)

EN61131-2:1994/A11:1996/A12:2000Programmable controllers -Equipment requirements and tests

Compliance with all relevant aspects of the standard. • Radiated electromagnetic field• Fast transient burst• Electrostatic discharge• Damped oscillatory wave

EN61131-2: 2007Programmable controllers -Equipment requirements and tests

Compliance with all relevant aspects of the standard.EMI• Radiated Emission• Conducted EmissionEMS• Radiated electromagnetic field• Fast transient burst• Electrostatic discharge• High-energy surge• Voltage drops and interruptions• Conducted RF• Power frequency magnetic field

For more details please contact the local Mitsubishi Electric sales site.• Notes for compliance to EMC LVD regulation.

It is necessary to install the CL1 series module in a shielded metal control panel.

• Use this product in Zone A*1 as defined in EN61131-2.

*1 Zone defined in EN61131-2Separation defined in EN61131-2 for EMC LVD regulation decideddepending on condition in industrial setting.Zone C = Factory mains which is isolated from public mains by dedicated

transformers.Zone B = Dedicated power distribution which is protected by secondary

surge protection. (300V or less in the rated voltage isassumed.)

Zone A = Local power distribution which is isolated from dedicated powerdistribution by AC/DC converters, isolation transformers, etc. (120V or less in the rated voltage is assumed.)

• When the following models use the CC-Link/LT power adapter model (CL1PAD1), a power line connecting to the external power supply terminal of the CL1PAD must be 30m(98’5’’) or less.- CL2AD4-B

- CL2DA2-B

1. Outline of ProductThis product is a power adapter connected to CC-Link/LT.This product supplies 24V DC power from an external power supply to the CC-Link/LT system.At least one power adapter is required per CC-Link/LT system.

2. Name of Each Part

2.1 Name of each part and assignmentDIN rail installation groovePower terminal

2-φ4.5 mounting hole(M4 mounting screw)

Status indicator LED

LINK connector

LINK/POWER connector

Terminal arrangement

24

G

+2

4V

Name DescriptionStatus indicator LED

POWER Lit while the power is supplied

Interface

LINK connector

DB For communicationDA For communication

LINK/POWER connector

24G Power supply for communication (-)DB For communicationDA For communication+24V Power supply for communication (+)

Power terminal

+24VSupplies power from outside to power adapter.Input voltage: 28.8V DC or less(depending on connected model)

Rated input current: 5.0 A(Use a proper external power supply under consideration of initial current of remote I/O modules.)

24G

2.2 Handling of LINK connector and LINK/POWER connector

1) LINK connector2) LINK/POWER connector

LINK connector:Executes only communication (does not supply power).Used when two or more power adapters are used in the CC-Link/LTsystem.

LINK/POWER connector:Executes communication, and supplies the power to the CC-Link/LTsystem.

3. Specifications1) General specifications

*1 The criterion is shown in IEC61131-2.

*2 The module cannot be used in an environment pressurized above theatmospheric pressure which can be generated around the altitude of 0 m.If the module is used in such an environment, it may fail.

*3 It indicates in which wiring area from the public wiring net to themechanical module inside the site the equipment is assumed to beconnected.The category ΙΙ applies, for example, to equipment whose power issupplied from a fixed facility.The surge-resistant voltage of equipment whose rating is up to 300V is2,500V.

COMM.

1

COMM.

1

Master module

Power adapter Power adapter

Externalpowersupply

Externalpowersupply

1)

2)

1)

2)

Item Specification

Ambient working temperature

0 to 55°C (32 to 131°F)

Ambient storage temperature

-25 to 75°C (-13 to 167°F)

Ambient operating humidity

5 to 95%RH: Dew condensation shall not be allowed.

Ambient storage humidity

5 to 95%RH: Dew condensation shall not be allowed.

Vibration resistance (*1)

Intermittent vibration is presentNumber of sweep times

Frequency Acceleration Half amplitude

10 times in each of X, Y and Z directions (80 min)

10 to 57Hz − 0.075mm

57 to 150Hz 9.8m/s2 −Continuous vibration is present

Frequency Acceleration Half amplitude

10 to 57Hz − 0.035mm

57 to 150Hz 4.9m/s2 −Impact resistance (*1) 147 m/s2, 3 times in each of X, Y and Z directions

Operating atmosphere

Corrosive gas should not be present.

Operating altitude 2,000m(6561'8") or less (*2)

Installation place Inside control panel

Over-voltage category

ΙΙ or less (*3)

Degree of contamination

2 or less (*4)

*4 This index indicates the degree of generation of conductive substances inthe environment in which the module is used. The degree of contamination2 indicates that contamination is caused by generation of only non-conductive substances.In this degree, however, temporary conduction may be caused byaccidental condensation.

2) Performance specifications

4. Construction CautionsInstallation of power adaptersAt least one power adapter is required per CC-Link/LT system.When constructing the system using only one power adapter, the followingthree conditions should be satisfied.If the following two conditions are not satisfied, use of two or more poweradapters in constructing the system.• The current capacity of the power adapter is 5A, therefore, total current

consumption should be an equivalent to or less than 5 A.• In order to operate the system in stable status, the voltage drop should be

equivalent to or less than 3.6 V.• The minimum operating voltage of each module connected to the power

adapter is 20.4 V, therefore, supply voltage subtracted by the voltage drop should be equivalent to or more than 20.4 V.

4.1 System power calculation method4.1.1 Current consumption calculation

*5 Some remote I/O modules for CC-Link/LT supply the power for I/O via theflat cable dedicated to CC-Link/LT.For the details, refer to the instruction manual of each remote I/O module.

4.1.2 Voltage dropCalculate the voltage drop based on the simplified graph or the calculationformula. (supply voltage: 24V DC, ambient temperature: 20°C)1) Selection based on the simplified graph

One power adapter is allowed within the range shown in the graphabove.

Item Specification

Voltage input range Depends on the connected model (28.8V DC max.).

Max. rated current

5.0A[Use the power adapter in the range in which the total current consumption of each unit does not exceed the maximum rated current while the power is supplied (except the period immediately after the power is turned on).]

Insulation resistance10MΩ between the external terminals as a whole and the ground terminal by 500V DC insulation resistance tester

External connection method

Supplies power from outside to power adapter:3 points (M3 screws) on terminal blockCommunication line/module power supply moduleCompatible with flat cable dedicated to CC-Link/LTConnector (with 4 pins) dedicated to CC-Link/LT × 2

Currentconsumptionin CC-Link/LT

system

Total currentconsumption ofeach module in

CC-Link/LT system

Total current consumptionof I/O equipment (suchas sensors) (to whichpower is supplied via

communication cable)*1

= + ≤ 5A

0.1

0.1(0'4")

1.0(3'3")

10(32'10")

100(328'1")

560(1837'3")

1.0 10

Max

imum

cab

le le

ngth

[m(in

ches

)]

Current consumption [A]

1000(3280'10")

2) Selection based on the calculation formula

*1 Some remote I/O modules for CC-Link/LT supply the power for I/O via the flatcable dedicated to CC-Link/LT.For the details, refer to the instruction manual of each remote I/O module.

The simplified graph and the calculation formula concerning voltage dropcalculations may not be accurate depending on the ambient temperatureand the number of used connectors dedicated to CC-Link/LT.If the driving voltage (20.4V) cannot be assured in a used remote I/Omodule, add another power adapter.

5. InstallationThe power adapter can be installed to a DIN rail or directly installed with screws.Each installation procedure is described below.

5.1 Installation directionDo not install the power adapter on the floor surface, the ceiling surface or in thevertical direction. If the power adapter is installed on such a surface or in such adirection, its temperature may rise.Make sure to install the power adapter on the wall horizontally.

5.2 Installation to DIN railAlign the upper DIN rail installation groove in the power adapter with the DIN rail1), and press the power adapter in that status 2).When removing the power adapter, pull downward the hook for installation toDIN rail 3), then remove the power adapter 4)

5.3 Direct installationScrew-tighten the power adapter by tightening M4 screws to the upper andlower mounting holes (two holes in all) provided in the power adapter.Install the module so that the clearance of 1 to 2mm (0.04" to 0.08") is assuredfor each module.

5.4 Crimp-style terminalFor the I/O wiring, use crimp-style terminals of the following dimensions.

Voltagedrop (V)

Maximumdistance (m)

+ Constant: 11

Constant: 0.06= × ≤ 3.6V× Total current

consumption (A)

Maximumdistance

Total currentconsumption

Furthest station from the power adapter

Total currentconsumption of eachmodule in CC-Link/LT

system

+Total current consumption of I/O

equipment (such as sensors)(to which power is supplied via

communication cable)*1

Applicable DIN rail

TH35-7.5Fe and TH35-7.5AI

1)

Installation Removal

2)3)

4)

Applicable screwM4 × 0.7mm(0.03") × 16mm(0.63") or more(Tightening torque range: 0.78 to 1.08 N⋅m)

6.2 mm (0.24" )or less

6.2 mm (0.24" )or less

Terminal

Terminal screwCrimp-styleterminal

Terminal screwCrimp-styleterminal

When wiring one cable to one terminal When wiring two cables to one terminal

Terminal

φ 3.2 (0.13") φ 3.2 (0.13")

• Tighten the terminal screws (M3 screws) on the terminal block with a tightening torque of 0.42 to 0.58 N⋅m. Do not tighten terminal screws with a torque outside the above-mentioned range. Failure to do so may cause short circuit, equipment failures, or malfunctions.

6. Power Wiring

• The external power supply is to be provided by the user.

• Use a proper external power supply with consideration for total current consumption and total initial current of remote I/O modules and I/O equipment (such as sensors) connected to the power adapter.

7. Outside Dimensions

Applicable crimp-style terminal

• RAV1.25-3• V1.25-3 (manufactured by JST Mfg. Co., Ltd.)• 1.25-3 and TG1.25-3

(manufactured by NICHIFU Co., Ltd.)

Applicable wire size

0.3 to 1.25 mm2

Connector forCC-Link/LTinterface - -

DA

- -DB

Internalcircuit

Connector forCC-Link/LT interface

Terminal block for power adapter

External power supply24V DC, 5A or less

Grounding(100Ω or less)

+24VDA

24GDB

LINK LINK/POWER

+- 24G

+24V

Power adapter

66(2.60") 90(3.55")

10(0.40")

85(3

.35")

5(0

.20")

43(1

.70")

2 - φ4.5(0.18") mountinghole (M4 mounting screw)

Center of DIN rail

Mass (Weight):

Approx. 0.26kg (0.58lbs)

75(2

.96")

± 0

.2(0

.01")

Unit: mm(inches)

Thank you very much for purchasing this product.

CL1PAD1Power Adapter Model

Please read this manual thoroughly before starting to use the product and handle the product properly.

User’s ManualMODEL CL1PAD1MANUAL Number JY997D04601GDate March 2018

Note: This symbol mark is for China only.

含有有害6物质的名称,含有量,含有部品

 本产品中所含有的有害6物质的名称,含有量,含有部品如下表所示。

产品中有害物质的名称及含量

本表格依据SJ/T 11364的规定编制。

:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572 规定的限量要求以下。

×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 26572规定的限量要求。

部件名称

有害物质

铅(Pb)

汞(Hg)

镉(Cd)

六价铬(Cr(VI))

多溴联苯(PBB)

多溴二苯醚(PBDE)

可编程控制器

外壳

印刷基板

×

「电器电子产品有害物质限制使用标识要求」的表示方式

基于中国标准法的参考规格:GB/T15969.2