ci i p i d icircuit protection devices & arc fault ...€¦ · 20 parallel arc faults in...
TRANSCRIPT
![Page 1: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/1.jpg)
environmental • failure analysis & prevention • health • technology development
IEEE Symposium on Product Compliance EngineeringAustin, Texas
20 22 O t b 200820 – 22 October, 2008
Ci i P i D iCircuit Protection Devices & Arc Fault Detection Schemes for ElectricalSchemes for Electrical Automotive Systems
Ashish AroraNosh Medora
Thomas LivernoisThomas Livernois
October 21, 2008
![Page 2: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/2.jpg)
2
IntroductionCircuit protection devices are used to provide protection against over/under-voltage, over-current and over temperature conditionsand over-temperature conditions.The suitability of a device depends on many factors such as transient/steady state voltage conditions such as transient/steady state voltage conditions, current and power ratings etc.The absence of a protection device or an The absence of a protection device or an inappropriately selected protection device may result in failures which may be catastrophic.
00G23PH.000 0000 1008 PR46
y p
![Page 3: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/3.jpg)
3
Introduction
00G23PH.000 0000 1008 PR46
![Page 4: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/4.jpg)
4
Introduction
00G23PH.000 0000 1008 PR46
![Page 5: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/5.jpg)
5
What are we protecting against?Current
Short circuit currentO l d tOverload current
VoltageOver voltageOver-voltageUnder-voltageTransientsTransients
TemperatureExcessive ambient temperature
00G23PH.000 0000 1008 PR46
Excessive ambient temperatureComponent heat dissipation
![Page 6: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/6.jpg)
6
CurrentUsually relies on heat generated by excess current to excess current to open circuit
FusesFusesFusible linksCircuit breakersPTCs
00G23PH.000 0000 1008 PR46
![Page 7: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/7.jpg)
7
FFuses
00G23PH.000 0000 1008 PR46
![Page 8: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/8.jpg)
8
00G23PH.000 0000 1008 PR46
![Page 9: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/9.jpg)
9
Positive Temperature Coefficient (PTC)
00G23PH.000 0000 1008 PR46
![Page 10: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/10.jpg)
10
P l i P iti T t C ffi i tPolymeric Positive Temperature Coefficient (PPTC)
00G23PH.000 0000 1008 PR46
![Page 11: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/11.jpg)
11
VoltageTwo categories of overvoltage circuit protection devicesprotection devices
Clamping/FoldbackMOVsMOVsDiodesTVSS
CrowbarGas discharge tubesThyristor surge
00G23PH.000 0000 1008 PR46
Thyristor surge suppressors
![Page 12: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/12.jpg)
12
MOVMOVUsed to protect equipment from power line transients and surgesgConsists of metal oxide grains sintered into ceramic disks and encapsulated in an epoxyThe MOV degrades over time due to the cumulative fusing of grains and the micro-cracking of the disks
00G23PH.000 0000 1008 PR46
![Page 13: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/13.jpg)
13
TemperatureProtection may or may not be re-settable
PTCPTCBi-metal switchesThermal FusesThermal Fuses
00G23PH.000 0000 1008 PR46
![Page 14: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/14.jpg)
14
Bi-Metal Switches
00G23PH.000 0000 1008 PR46
![Page 15: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/15.jpg)
15
Automotive Electrical Systems
12 V
42 V
360 V
00G23PH.000 0000 1008 PR46
![Page 16: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/16.jpg)
16
So What is the Problem?
Arcing!!!
00G23PH.000 0000 1008 PR46
![Page 17: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/17.jpg)
17
What is Arcing?
The effect generated when electrical current bridges the air gap between two contacts or conductors
• Arcing may take two g yforms in a typical automotive environment:
S i A i• Series Arcing• Parallel Arcing
00G23PH.000 0000 1008 PR46
![Page 18: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/18.jpg)
18
Ref: 42VDC Arc Faults: Physics and Test M h d E lb H d J
Arc FaultsMethods, Engelbert Hetzmannseder, Joe Zuercher
Parallel Arc Fault
Series Arc Fault
00G23PH.000 0000 1008 PR46
![Page 19: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/19.jpg)
19
Series ArcingFaults in series with the load Arcing currents less than nominal circuit currentsOccurs on loose (lugs/terminals), broken (conductors) or otherwise high resistance segment in a single line Cannot be detected by using conventional short circuit or overload protection devices M lt i l li bilit d fi h d May result in low reliability and a fire hazard
00G23PH.000 0000 1008 PR46
![Page 20: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/20.jpg)
20
Parallel ArcFaults in parallel with the loadArcing currents significantly higher than the nominal
tcurrentsOccurs when damaged wires or wires exposed due to
i i l ti t h t d ili l aging insulation touch system ground or auxiliary low voltage bus May/may not trip the fuse or breaker due to current May/may not trip the fuse or breaker due to current limiting nature of the arcPotentially more dangerous than a series fault
00G23PH.000 0000 1008 PR46
Potentially more dangerous than a series fault condition
![Page 21: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/21.jpg)
21
Arc Physicsy
00G23PH.000 0000 1008 PR46
Ref: 42VDC Arc Faults: Physics and Test Methods, Engelbert Hetzmannseder, Joe Zuercher
![Page 22: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/22.jpg)
22
Arc-Fault Current Interrupters (AFCI)Required in all circuits that feed receptacles in bedrooms of dwelling units since 1999 by the National Electric CodeAd d l t i i id AFCI b k d t t Advanced electronics inside an AFCI breaker detect sudden bursts of electrical current in milliseconds, long before a standard circuit breaker or fuse would tripbefore a standard circuit breaker or fuse would tripThe 2008 NEC requires installation of combination-type AFCIs in all 15 and 20 amp residential circuits with some AFCIs in all 15 and 20 amp residential circuits with some exceptions (laundries, kitchens etc.)
00G23PH.000 0000 1008 PR46
![Page 23: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/23.jpg)
23
What about DC systems?Series Arc Faults
Plugging and unplugging connectors under loadLose lugsB k i iBreaks in wires
Parallel Arc FaultsSi l ti f tti i ( i t t t t t)Simulation of cutting wires (point contact arc test)Simulation of chafed wires (dry arc propagation test)Influence of contamination (carbonized track test)Influence of contamination (carbonized track test)Water intrusion test of connectorsImpact of humidity & salt water (wet-arc propagation test)
00G23PH.000 0000 1008 PR46
p y ( p p g )Simulation of broken/dangling wire (dangling wire test)
![Page 24: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/24.jpg)
24
Wh ’t ti l i itWhy can’t we use conventional circuit protection devices? Ref: Mitigation and Analysis of Arc Faults in Automotive DC
Networks, Naidu et all, IEEE Transactions on Power Electronics, Vol. 21, No. 3, May 2006, , y
Parallel Arc Fault
S i A F ltSeries Arc Fault
00G23PH.000 0000 1008 PR46
![Page 25: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/25.jpg)
25
What is out there?What is out there?
Ref: Mitigation and Analysis of Arc Faults in Automotive DC Networks, Naidu et all, IEEE
00G23PH.000 0000 1008 PR46
Ref: Mitigation and Analysis of Arc Faults in Automotive DC Networks, Naidu et all, IEEE Transactions on Power Electronics, Vol. 21, No. 3, May 2006
![Page 26: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/26.jpg)
26
Ref: Mitigation and Analysis of Arc Faults in
00G23PH.000 0000 1008 PR46
Automotive DC Networks, Naidu et all, IEEE Transactions on Power Electronics, Vol. 21, No. 3, May 2006
![Page 27: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/27.jpg)
27
What do we want to do & whyWhat do we want to do & why
00G23PH.000 0000 1008 PR46
![Page 28: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/28.jpg)
28
Test SetupBattery
PowerSupply
yBank
SupplyLoad
Motor Controller Motor Coupling
/ShaftCopper
RodCopper
Rod
IV
00G23PH.000 0000 1008 PR46
OscilloscopeString pot
![Page 29: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/29.jpg)
29
Test Setup
00G23PH.000 0000 1008 PR46
![Page 30: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/30.jpg)
30
T t S tTest Setup
00G23PH.000 0000 1008 PR46
![Page 31: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/31.jpg)
31
Test Setup
00G23PH.000 0000 1008 PR46
![Page 32: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/32.jpg)
32
Factors
Factor Description
Main Factor
Designation
Low Level
(-)
Center Point
High Level
(+)g
Circuit Inductance A 0 H 500 mH 1 H Voltage B 20 31 42 Current C 100 mA 5 A 10 ASpeed of separation D 1 cm/sec 10 cm/sec 20 cm/sec Copper Purity E 50 % 75 % 95 % Temperature F -10°C 25°C 80 °C Relative Humidity G 5% 50% 95%Relative Humidity G 5% 50% 95%
00G23PH.000 0000 1008 PR46
![Page 33: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/33.jpg)
33
Series Arcs
Ref: Voltage-Current Characteristics of Breaking Arc at Constant Opening Speed in the Air,
00G23PH.000 0000 1008 PR46
Arc at Constant Opening Speed in the Air, Sekikawa et all, IEEE Transactions on Components & Packaging Technologies, Vol. 27, No. 1, March 2004
![Page 34: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/34.jpg)
34
Arc Discharge Voltage Profile
00G23PH.000 0000 1008 PR46
Ref: Voltage-Current Characteristics of Breaking Arc at Constant Opening Speed in the Air, Sekikawa et all, IEEE Transactions on Components & Packaging Technologies, Vol. 27, No. 1, March 2004
![Page 35: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/35.jpg)
35
Test ResultsTest Results
1100 µH
20 H20 µH
00G23PH.000 0000 1008 PR46
![Page 36: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/36.jpg)
36
T t R ltTest Results
20 µH
3300 µH
00G23PH.000 0000 1008 PR46
![Page 37: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/37.jpg)
37
Test Results – 3 mm/secondTest Results – 3 mm/second
00G23PH.000 0000 1008 PR46
![Page 38: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/38.jpg)
38
T t R lt 10 / dTest Results – 10 mm/second
00G23PH.000 0000 1008 PR46
![Page 39: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/39.jpg)
39
Test ResultsThe current waveform shows an initial drop in current when the arc is initiatedIt b ibl t thi d i t t d t t It may be possible to use this drop in current to detect the initiation of a series arcing eventTh f ll ti f th t i d d t th The fall time of the current is dependant on the inductance as expectedBased on the testing performed it appears that the Based on the testing performed, it appears that the minimum di/dt is approximately 2 mA/µs
This figure is not dependant upon speed of separation or the
00G23PH.000 0000 1008 PR46
This figure is not dependant upon speed of separation or the magnitude of current
![Page 40: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/40.jpg)
40
Next Steps
Factor Description
Main Factor
Designation
Low Level
(-)
Center Point
High Level
(+)
Circuit Inductance A 0 H 500 mH 1 H Voltage B 20 31 42 Current C 100 mA 5 A 10 A Speed of separation D 1 cm/sec 10 cm/sec 20 cm/secCopper Purity E 50 % 75 % 95 % Temperature F -10°C 25°C 80 °C Relative Humidity G 5% 50% 95%y % % %
00G23PH.000 0000 1008 PR46
![Page 41: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/41.jpg)
41
Next StepsDetermination of the effects of untested factors on the fall timeD i i l t ti d t t f i l i it t Design, implementation and test of a simple circuit to provide series arc fault protectionS li th t t hi h ltScaling the measurement to higher voltagesIdentifying parameters and potential simpler solutions to parallel arc faultsto parallel arc faults
00G23PH.000 0000 1008 PR46
![Page 42: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/42.jpg)
42
SummarySeries arcs may not always be detected by circuits because of the damping effect of the long wire harnessesharnessesCircuit protection devices commonly available are not designed to detect series arcs specially in automotive designed to detect series arcs specially in automotive applicationsWhat is required is a detection mechanism as close to What is required is a detection mechanism as close to the location of the series arc as possible
00G23PH.000 0000 1008 PR46
![Page 43: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/43.jpg)
43
SummaryPreliminary testing indicates that a minimum di/dt of approximately 2 mA/µs will be observed at the initiation of the series arcinitiation of the series arcA time delay circuit with an integrator/comparator may be implemented to detect and take corrective action in be implemented to detect and take corrective action in the event of a series arc
00G23PH.000 0000 1008 PR46
![Page 44: Ci i P i D iCircuit Protection Devices & Arc Fault ...€¦ · 20 Parallel Arc Faults in parallel with the load Arcing currents significantly higher than the nominal currents Occurs](https://reader035.vdocuments.mx/reader035/viewer/2022071213/602da0c86b47891f0c628c95/html5/thumbnails/44.jpg)
44
QUESTIONS?QUESTIONS?
Nosh MedoraSenior Member, IEEE
Exponent
Ashish AroraMember, IEEE
Exponent
Thomas LivernoisMember, IEEE
ExponentExponent23445 North 19th Avenue
Phoenix, AZ [email protected]
Exponent23445 North 19th Avenue
Phoenix, AZ [email protected]
Exponent39100 Country Club Drive,
Detroit, MI [email protected]