chloride-brochure-plante-yap.ycp_.yhp_.pdf

4
Complies with: IEC 60896-1 and BS 6290 Planté Cells

Upload: sqhuet

Post on 13-Sep-2015

213 views

Category:

Documents


1 download

TRANSCRIPT

  • Complies with: IEC 60896-1 and BS 6290

    Plant Cells

  • Product and Service BenefitsLocally-Manufactured RangeManufactured by a South African company, proven under South African conditions.

    Nationwide After-Sales SupportCountrywide network of branches and agencies, with access to information to ensure sound technical backup.Proven ReliabilityUsed successfully, achieving claimed life, in numerous applications.Customer CareEvery Chloride standby cell carries a comprehensive product warranty backed by the industry leader andsupported by a national distributor network.

    POSITIVE PLATES are 8mm thick pure lead grids for longer life and to provide sufficient material to ensure that thereis no fall-off of capacity throughout the life of the cell.

    NEGATIVE PLATES are of industrial pasted grid construction, for balanced performance and life.

    SEPARATORS made of microporous rubber, for exceptionally long life and have high degree of porosity, ensuringminimum internal resistance.

    TRANSPARENTCONTAINERS, moulded from transparent styrene acrylonitrile(SAN) to provide optimum transparencyand very high insulating qualities, eliminating the need for separate cell insulators

    CELL LIDS. Moulded from opaque SAN. Are permanently sealed to the container.

    VENT PLUGS are of a special design which effectively returns all acid spray to the cell, but allows free exit of oxygenand hydrogen gases.

    FLOAT CHARGINGAs these cells are designed for standby applications they should be float charged to ensure that they remain fullycharged, ready for instant use,at all times. Correct float voltage settings may vary depending upon operational differencebut as a guideline 2.25 volts per cell at 25C may be used as a level of charge which will minimise the need for equalisingcharges whilst providing acceptable life. The installation and maintenance manual should be read for further information.

    SPECIFIC GRAVITYA simply hydrometer reading indicates the state of charge. A fully charged cell will have a specific gravity of 1.210.

    VOLTAGEThe nominal voltage is 2 volts per cell, i.e. a nominal 110V battery will have 55 cells. On discharge, the recommendedfinal voltage at which the discharge should be terminated depends on the discharge rate. For example, dischargecurves indicate that the final voltage for the three hour rate of discharge is 1.8 volts. It is not recommended to continuedischarging the cells once the final voltage has been reached as the voltage will fall away at an increasing rate withminimal gain of discharge duration and the risk of over-discharge.

    CAPACITYThe capacity of these cells is normally rated at the 10hour rate of discharge although the capacity which can be takenfrom a cell will vary the discharge rate, as indicated in the capacity table. Capacity is also affected by temperature.

    INSTALLATIONThese cells can be connected either edge to edge or face to face. The standard method of connection is to follow theshortest distance between two terminals.

    RECHARGINGThe cells ampere hour efficiency is 90%. To fully recharge the cells the amount of charge required is equal to theamount of discharge in ampere hours plus 11%.

    Technical Details

    Design FeaturesDesigned for all standby duties including power stations, telephone exchanges, switchgear operation, telecommunications,emergency lighting and diesel starting.

    Noteworthy advantages of these cells are:

    ease of inspection, test and maintenance (a hydrometer reading indicates the state of charge) lower internal resistance which provides increased performance at high rates of discharge. no falling-off of capacity with age. life expectancy of 20 years or longer. designed for float-charge operation, always ready for use.

    Premier QualityConforms to BS 6290 1984 and IEC standards and manufactured to ISO 9001:2000 quality standards.

  • Type Initia lCharg eCu rrent

    W eight Extern al d imen sio ns o fce ll containe r

    Ove rallh eigh tof cell

    Cen tre so f

    ce lls

    Ca pa city in amp ere-hou rs at 2 5C

    wh en discha rged in

    10 Hrs 3 Hrs 1 Hr

    Cellcomp l.fi l led

    Acido nly

    1.2 10sg

    Fina lvoltage

    Len gth Wid th Heigh t

    W idth o fs ing le ro w

    stil lag eor stand

    Wid th ofdo uble

    rowstil lage

    o r sta nd

    1 .85 1.80 1 .7 5 Amps Kg Kg mm mmmm mm mm mm mm

    Appro x.q ua ntit yof acid

    1 .2 10sg

    Litre s

    YAP 5

    YAP 9

    YAP 13

    YAP 1 7

    YAP 2 1

    YCP 9

    YCP 11

    YCP 13

    YC P 1 7

    YC P 2 1

    YHP 11

    YHP 13

    YHP 15

    YHP 1 7

    YHP 19

    YHP 2 1

    YHP 23

    YHP 25

    YHP 27

    YHP 29

    YHP 31

    YHP 33

    YHP 35

    YHP 37

    YHP 39

    YHP 41

    16

    32

    48

    64

    80

    10 7

    1 34

    1 61

    2 14

    2 68

    3 22

    3 75

    4 29

    455

    5 36

    6 43

    7 50

    85 8

    9 65

    10 72

    11 79

    12 86

    13 94

    15 01

    16 08

    17 15

    18 22

    19 30

    20 37

    21 44

    1 3

    26

    38 .5

    52

    64

    86

    1 07

    129

    172

    215

    258

    30 1

    344

    365

    438

    526

    614

    7 02

    789

    8 77

    965

    1 052

    1 140

    1 228

    131 5

    140 3

    149 1

    1 578

    1 666

    1 754

    The len gth o f a sta nd is n x cell ce ntre wh ere n is th e n umb er of cells in a ro w.

    9.8

    19 .5

    2 9.5

    3 9

    4 9

    6 5

    8 2

    9 8

    13 1

    163

    19 6

    22 9

    26 2

    27 8

    32 7

    3 92

    45 8

    5 23

    58 9

    65 4

    7 19

    78 5

    85 0

    91 5

    98 1

    104 6

    11 12

    11 77

    12 42

    13 08

    1

    2

    3

    4

    5

    7

    8 .5

    1 0

    14

    1 7

    21

    2 4

    3 2

    2 8

    35

    4 2

    4 9

    5 6

    63

    70

    7 7

    8 4

    91

    9 8

    1 05

    1 12

    11 9

    1 26

    13 3

    1 40

    3.8

    6.3

    10

    11 .45

    1 3.6

    18 .6

    22.2

    24 .9

    30.6

    36 .9

    43 .4

    5 4.4

    58 .4

    60 .4

    95 .2

    106 .2

    1 33 .5

    1 44 .5

    1 55 .5

    1 79 .3

    1 90 .4

    2 18 .0

    2 29 .0

    2 40 .1

    26 8.3

    2 79 .2

    29 0.2

    31 8.2

    3 29 .2

    34 0.2

    1.1 6

    1.89

    3.4

    3 .2 5

    3.8

    5 .5

    7 .5

    7 .2

    8.7

    10 .4

    1 2.1

    1 6.2

    15 .5

    15 .1

    32.2

    30 .6

    45.3

    43.7

    42 .1

    53.3

    51.8

    68.8

    65 .2

    63 .7

    79 .3

    77 .6

    76 .0

    9 1.4

    89.8

    88 .2

    0.9 6

    1.56

    2.8 3

    2.68

    3.16

    4 .5

    6 .2

    5 .9

    7.2

    8 .6

    10 .0

    1 3.4

    1 2.8

    12 .1

    2 7.1

    25.7

    38 .1

    36.7

    35.4

    44 .8

    43.5

    56.1

    54.8

    5 3.5

    6 6.6

    65 .2

    63.9

    76 .8

    75.5

    74.1

    7 6

    114

    190

    190

    2 28

    1 34

    1 72

    1 72

    2 10

    2 48

    2 86

    3 62

    3 62

    3 62

    23 0

    23 0

    30 6

    306

    30 6

    357

    3 57

    4 33

    433

    433

    5 09

    5 09

    5 09

    5 85

    58 5

    5 85

    13 3

    13 3

    13 3

    13 3

    13 3

    20 3

    20 3

    20 3

    20 3

    20 3

    20 3

    20 3

    20 3

    20 3

    36 8

    36 8

    3 68

    3 68

    36 8

    3 68

    36 8

    36 8

    36 8

    36 8

    3 68

    36 8

    36 8

    36 8

    36 8

    212

    212

    212

    212

    212

    349

    349

    349

    349

    349

    349

    349

    349

    349

    592

    5 92

    5 92

    59 2

    5 92

    5 92

    592

    592

    5 92

    592

    592

    592

    5 92

    5 92

    592

    592

    2 60

    2 60

    2 60

    2 60

    2 60

    4 23

    42 3

    4 23

    4 23

    4 23

    4 23

    4 23

    4 23

    4 23

    6 82

    68 2

    68 2

    682

    68 2

    68 2

    6 82

    6 82

    6 82

    6 82

    6 82

    6 82

    68 2

    68 2

    6 82

    6 82

    8 3

    1 21

    1 40

    1 40

    1 40

    1 40

    1 78

    1 78

    2 09

    2 09

    2 09

    2 09

    2 09

    2 09

    33 0

    33 0

    38 8

    3 88

    38 8

    40 0

    40 0

    40 0

    40 6

    42 6

    4 64

    54 2

    54 2

    54 2

    37 0

    37 0

    37 0

    3 70

    37 0

    36 0

    36 0

    43 5

    435

    43 5

    51 0

    51 0

    51 0

    58 6

    58 6

    58 6

    50 8

    50 8

    66 6

    66 6

    66 6

    71 0

    71 0

    71 0

    66 2

    74 2

    81 8

    97 4

    97 4

    97 4

    96 9

    96 9

    96 9

    96 9

    96 9

    94 9

    9 49

    109 9

    109 9

    109 9

    124 9

    1 249

    124 9

    140 1

    1 40 1

    1 40 1

    Plant, Capacities, Weights And Dimensions

    3 68

    YCP 2 5

    YCP 2 9

    YCP 3 3

    YCP 3 5

    240

    240

    315

    315

    31 5

    379

    3 79

    3 79

    3 79

    3 79

    379

    379

    379

    379

    379

    3 79

  • ESTABLISHED IN 1931, FIRST NATIONAL BATTERY IS A LEADING MANUFACTURER OF LEAD ACID BATTERIES IN SOUTH AFRICA.

    THE COMPANY PRODUCES MORE THAN 2 000 000 BATTERIES ANNUALLY TOPROVIDE ELECTRICAL POWER FOR PASSENGER CARS, TRUCKS, TRACTORS, FORKLIFT TRUCKS, BOATS, RAILWAY

    LOCOMOTIVES AND COACHES, UNDERGROUND LOCOMOTIVES AND MINERS CAP LAMPS,POWER STATIONS, SWITCH YARDS, FARM LIGHTING,

    SOLAR SYSTEMS, COMPUTERS, TELECOMMUNICATIONSEQUIPMENT ... AND A HOST OF OTHER USES.

    FIRST NATIONAL BATTERY ACKNOWLEDGES THAT SUPERIOR TECHNOLOGY,CONSISTENT PRODUCT QUALITY AND DEDICATED CUSTOMER SERVICE ARE MINIMUM REQUIREMENTS TO

    ENABLE THE COMPANY TO MAINTAIN ITS POSITION AS AN INDUSTRY LEADER.

    THE COMPANYS VALUES ARE REPRESENTED BY ITS MOTTO: THROUGH CARING WE LEAD

    PROOF OF THESE VALUES IS TO BE FOUND IN THE MANY PRODUCT AND SERVICE QUALITY AWARDS AND CERTIFICATESPRESENTED TO FIRST NATIONAL BATTERY OVER MANY YEARS OF SERVICE TO BATTERY USERS.

    4 DEDICATED MANUFACTURING SITES

    BUFFALO VIEW ROAD, EAST LONDON 6 000M2

    FACTORYISO 9001: 2000 AND ISO 14001 CERTIFIEDINDUSTRIAL BATTERY MANUFACTURING

    FORKTRUCK BATTERIES: STANDBY BATTERIES: MINING BATTERIES

    SETTLERS WAY, EAST LONDON 9 200M2 FACTORYISO/TS 16949:2002 AND ISO 14001 CERTIFIED

    AUTOMOTIVE BATTERY MANUFACTURING7 000 BATTERIES PER DAYALSO TECHNICAL CENTRE

    FORT JACKSON 5 000M2

    FACTORYISO/TS 16949:2002 AND ISO 14001 CERTIFIED

    PLASTIC INJECTION MOULDING50 TON-860 TON INJECTION MOULDING MACHINES

    18 MILLION PIECES PER ANNUMALSO TOOLROOM

    LIVERPOOL ROAD BENONIISO/TS 16949:2002 AND ISO 14001 CERTIFIED

    LEAD SMELTER8 000 TONS RECYCLED LEAD PER ANNUM

    ALSO WAREHOUSING & DISTRIBUTIONFORMATION & FINISHING LINE

    MARKETING & FINANCE DIVISIONS

    BENONICOR LIVERPOOL & BRISTOL ROADS, BENONI SOUTHP.O. BOX 5015 BENONI SOUTH 1502, SOUTH AFRICA

    TEL: +27 11 7413600FAX: +27 11 421-2642 / 462-1625

    01/07

    First National Battery

    FIRST NATIONAL BATTERY IS THE REGISTERED USER OF THE TRADEMARK CHLORIDE IN SOUTH AFRICA.

    IN THE INTERESTS OF CONTINUING ADVANCEMENT WE RESERVE THE RIGHTTO MODIFY SPECIFICATIONS WITHOUTPRIOR NOTICE.

    COPYRIGHT SUBSISTS IN THIS WORK. ANY UNAUTHORISED REPRODUCTION, ADAPTION AND COPYING OF THISDOCUMENT ARE ACTS OF COPYRIGHT INFRINGEMENTS AND ENTITLES FIRST NATIONAL BATTERY TO TAKE ACTION

    (BOTH CIVILLY AND CRIMINALLY) AGAINST THE INFRINGER.

    FIRST NATIONAL BATTERY WILL REMAIN THE EXCLUSIVE MANUFACTURER OF BATTERIES ANDSUPPLIER OF PRODUCTS AND SERVICES TO FIRST NATIONAL BATTERY INDUSTRIAL. IN KEEPINGWITH THEIR OBJECTIVE TOWARDS TRUE BLACK EMPOWERMENT.