chemtronics technologies (i) pvt. ltd

42
Chemtronics Technologies (I) Pvt. Ltd.

Upload: gunda

Post on 10-Jan-2016

22 views

Category:

Documents


2 download

DESCRIPTION

Chemtronics Technologies (I) Pvt. Ltd. About Us. We are a technological solution provider in Air, Water & Waste Treatment. Started in 2004 at Mumbai, India, with a primary objective to give “Environment Friendly” Products & Solutions. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Chemtronics Technologies (I) Pvt. Ltd

Chemtronics Technologies (I) Pvt. Ltd.

Page 2: Chemtronics Technologies (I) Pvt. Ltd

About Us

We are a technological solution provider in Air, Water & Waste Treatment.

Started in 2004 at Mumbai, India, with a primary objective to give “Environment Friendly” Products & Solutions.

Being a member of Indian Green Building Council, the core of our philosophy revolves around designing Sustainable Green Building Solutions by “Integrating Technologies”, customizing to retrofit and suit end user’s requirement & give a complete solution.

We strictly adhere to International standards and stringent quality controls backed with ISO guidelines.  

Page 3: Chemtronics Technologies (I) Pvt. Ltd

Our Solutions on

Indoor Air Quality

Page 4: Chemtronics Technologies (I) Pvt. Ltd

“How Green is Your Indoor Air?”

Page 5: Chemtronics Technologies (I) Pvt. Ltd

This refers to a level of acceptable Indoor Air Quality.

“According to ASHRAE, acceptable Indoor Air Quality is air in which there are no contaminants, odors, or sensory irritants at concentrations that are known to pose a health risk as determined by cognizant authorities, and with which a substantial majority of the people exposed do not express dissatisfaction”.

Page 6: Chemtronics Technologies (I) Pvt. Ltd

Indoor Air Quality Concern

Indoor Air Environment contains a variety of visible & invisible contaminants. Airborne diseases are 2 to10 times higher in indoor then outdoor. Due to increasing use of synthetic building materials, the quality of indoor air diminishes resulting in Building-Related Symptoms (BRS).Such as:Headache, Eye Irritation,

Nose & Throat Irritation, Allergy & General Fatigue to name a few examples.

Page 7: Chemtronics Technologies (I) Pvt. Ltd

VOC in Indoor Air

In indoor environment Toxic Gases are emitted from wide variety of sources :Building Materials, Cleaners, Plastics, Wood Products, Paints, Carpets, Polishers, Deodorants, etc… know as Volatile Organic Compound (VOC)

It adversely effect to:

Allergy, Asthma, Eye & Nasal irritation, Affect respiratory tracts….

Page 8: Chemtronics Technologies (I) Pvt. Ltd

Carbon –di-oxide in Indoor Air

In an indoor environment human being Exhale CO2.Carbon dioxide cannot be reduced or oxidized.

It is not a toxic or carcinogen but a high level of CO2, causes:

Headaches, Restlessness, Difficulty Breathing, Sweating, Tiredness, Increased Heart Rate, Elevated Blood Pressure,etc…

Page 9: Chemtronics Technologies (I) Pvt. Ltd

Odour in Indoor Air

Odour is a major Irritants & it is cause from various sources:

Food Odour Body Odour Mold, Fungi & Microbes Cleaning Chemical Odour, etc

This is a residual odour & difficult to dilute from conventional method.

Page 10: Chemtronics Technologies (I) Pvt. Ltd

These are collectively know as “ SICK BUILDING SYNDROME”

Page 11: Chemtronics Technologies (I) Pvt. Ltd

To address Sick Building Syndrome (SBS) the AHU system take “ Outdoor Air” to dilute Volatile Organic Compound (VOC) and reduce

Carbon dioxide (CO2) with in acceptable limits.

Conventionally Fresh Air is used to improve Indoor Air Quality (IAQ)

Page 12: Chemtronics Technologies (I) Pvt. Ltd

Fresh air is not cheap!

Hot and humid air needs to be cooled down to

room temperature.

Page 13: Chemtronics Technologies (I) Pvt. Ltd

Hidden Cost Of Fresh Air by AHU

Load profile of fresh air taken by Air Handling

Unit

60% to cool moisture …

wasted energy

28% to cool nitrogen

…..wasted energy

12% to cool oxygen

…..the only useful

component in fresh air.

Load Profile

MoistureNitrogenOxygen

Page 14: Chemtronics Technologies (I) Pvt. Ltd

35%

65%

Cooling Load Breakup for COMMERCIAL BUILDING

FRESH AIR COOL-ING LOAD

Page 15: Chemtronics Technologies (I) Pvt. Ltd

60%

40%

Energy Consumption in COMMERCIAL BUILDINGS

HVAC

OTHER UTILITIES AND LIGHTING

Page 16: Chemtronics Technologies (I) Pvt. Ltd

Energy Consumed by AHU

Energy Consumed by AHU to take “Fresh Air”.

150 CFM of Fresh Air in a Commercial Building will require 1ton of cooling load . (Approximately)

This will consume:1 Kw energy for a water cool system. (or) 1.3 kw of energy for an air cool system.

Page 17: Chemtronics Technologies (I) Pvt. Ltd

Chemtronics’ Solutions to minimize “Fresh Air Intake”

Page 18: Chemtronics Technologies (I) Pvt. Ltd

How to reduce “Fresh Air”

By using controlled injection of ozone.

Oxidation of VOC is performed by ozone and not by oxygen of

the fresh air.

Ozone is more powerful oxidizing agent than oxygen.

In the presence of a more powerful oxidant, less powerful

oxidant does not have the chance to perform oxidation, until no

more of the former is available.

oxygen of the fresh air is preserved and not spent in performing

the task of oxidizing the VOC, which is now transferred to ozone.

Available oxygen is now used entirely to maintain CO2.

Intake of fresh air is reduced drastically. Thus fresh air

requirement goes down to 5CFM or less per person.

Page 19: Chemtronics Technologies (I) Pvt. Ltd

Position of ASHRAE

ASHRAE approves reduction in fresh air, if chemical contaminants in air are removed.

We refer you to the following sections of ASHRAE62-99: “ Procedure for use of cleaned recirculated air: The amount of outdoor air may be reduced by recirculating air from which offending contaminants have been removed or converted to less objectionable forms. Formaldehyde, for example may be oxidized to water and carbon dioxide. The amount of outdoor air depends on the contaminants generated in the space, etc ......”.

Page 20: Chemtronics Technologies (I) Pvt. Ltd

ASHRAE Standards

ASHRAE Ventilation code no. 62-1999.

Minimum 15 CFM per person fresh air is required.

Minimum of 30 CFM fresh air is required if smoking is permitted.

Page 21: Chemtronics Technologies (I) Pvt. Ltd

Ozone Technologies

Page 22: Chemtronics Technologies (I) Pvt. Ltd

Ozone Technological Solution Ozone is tri atomic Oxygen O3 is a very strong

disinfectant & oxidant. Any pathogen or contaminant that can be disinfected, altered or removed via an oxidation process, will be affected by ozone.

It is the strongest of all molecules available for disinfection

Page 23: Chemtronics Technologies (I) Pvt. Ltd

Approved Safe Ozone levels

Maximum Permissible Concentration in Occupied space:

ASHRAE : 0.05PPM (50PPB)

OSHA: 0.1 PPM (100PPB) Exposure of 8hrs/day, 5 days a week

FDA: 0.05 PPM (50PPB)

Continuous exposure 24hrs/day 365 days a year if Ozone concentration exceeds, It becomes a toxic gas.

Page 24: Chemtronics Technologies (I) Pvt. Ltd

Chemtronics’ Ozone System Advantage

Ozone is produced using medical grade oxygen. The ozone produced is pure ozone. There is no nitrogen oxides are present ( As in case

of Duct Mounted ozone generator). The concentration of ozone is low and well within

permissible limit(0.1ppm).

Page 25: Chemtronics Technologies (I) Pvt. Ltd

Safety Measures

Ozone sensors, VOC sensors & Timers are used to monitor air quality.

Machines are interlocked with AHU to provide safety operations.

Special Di-Electric with coating and air cooling ensure long life to electrode.

Page 26: Chemtronics Technologies (I) Pvt. Ltd

Environment Benefit

Page 27: Chemtronics Technologies (I) Pvt. Ltd

Environment Benefits

Chemtronics OZONE SYSTEM ACHIEVES :

Dramatic reduction in build up of VOC’s. Dramatic Reduction in Odours. Depletion of Microbial Colonies (Fungi) in Ducts and

AHU cooling coils. Eliminates duct cleaning. Oxidize air borne bacteria. Address Cross Infections. Keeps the Indoor Air pure & healthy.

Page 28: Chemtronics Technologies (I) Pvt. Ltd

Research indicates that improvement in IAQ:

Increases productivity by 5-10 % & more.Reduces asthma by 8% - 25%.Reduces other respiratory illnesses by 23

% - 76 %.

Page 29: Chemtronics Technologies (I) Pvt. Ltd

Economic Benefits

Page 30: Chemtronics Technologies (I) Pvt. Ltd

Reduction in Capital Cost

Reduction in fresh air intake will reduce the overall HVAC plant capacity sizes:1. Chiller, Cooling Tower.2. Condenser water and chilled water pumps.3. Pipe sizes and Insulation.4. Electric / Stream Duct heaters.5. Electrical Panel & Cables.6. Stand by diesel generator.7. Plant room space.

Page 31: Chemtronics Technologies (I) Pvt. Ltd

Reduction in Operating Cost

Reduction in fresh air intake will reduce the Cooling load. Reduction in HVAC capacity will result in the following:

1) Reduction in Energy consumption to run HVAC System

2) Reduction in Water consumption to run HVAC System3) Cost of Maintenance (Labour and Material)

Page 32: Chemtronics Technologies (I) Pvt. Ltd

Reduced Fresh AirCooling LoadAfter Ozonization

Savings in LoadDue to Ozonization

Other Cooling Load

10%

25%

65%

Saving In HVAC Load

Page 33: Chemtronics Technologies (I) Pvt. Ltd

Reduction in Fresh Air Intake Reduces HVAC over all plant capacity & Operating cost

by 15- 20%

Page 34: Chemtronics Technologies (I) Pvt. Ltd

RETURN ON INVESTMENT ( ROI)

ROI BASED ON MAINTENANCE

1 to 2 YEARS

Depends on Ambient Conditions, Cost of Electricity, Water, and Hours of Plant Operation

Page 35: Chemtronics Technologies (I) Pvt. Ltd

Ozone Technology

Page 36: Chemtronics Technologies (I) Pvt. Ltd

Ozone Generator Technology

Air Feed Oxygen Feed

In Duct -Plate type

External - Injection

External - Injection

Page 37: Chemtronics Technologies (I) Pvt. Ltd

Comparison Air Fed v/s Oxygen Fed Ozone Generator

Page 38: Chemtronics Technologies (I) Pvt. Ltd
Page 39: Chemtronics Technologies (I) Pvt. Ltd

G.A. Drawing

Page 40: Chemtronics Technologies (I) Pvt. Ltd

Client List - Air Ozonation

Page 41: Chemtronics Technologies (I) Pvt. Ltd

Contact Us

Mr. Sunil Shah – +91 9321234527Mr. Manzoor Khan – + 91 9699788387

Tel: 022-65269554/[email protected]

Page 42: Chemtronics Technologies (I) Pvt. Ltd

Thank You