CHEMICAL INJECTION SKIDS
1
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Typical chemical injection Skid (Vertical Tank)
Storage tank
Level gauge
Injection Pump
Flow meter
Electrical JB&LCP
Skid drainSkid base frame
Lifting Lug
Calibration pot
PRV.
Pulsation Dampener
Suction line Strainer
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Typical chemical injection Skid(Horizontal Tank)
LCP
Ladder platform &handrails
Man way
Over flow with sight glass
Flow meter corolius type
Level transmitter
Gooseneck Vent
Loading Line
Suction Line Strainer
3
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
PUMPS
Diaphragm Type
Plunger Type
Single Head
Multi Head
Manual control
Automatic Control
4
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Installation of Pumps
Pump should be raised for easily connect suction Lines
Pump should be easily accessible for maintenance
No pipe line should be routed above the pump which restricts accessibility and removal of pump
Take special care If Pump using Electrical/Pneumatic activators it need more space for pump installation
5
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
TanksCommon Type of Tanks
Horizontal Cylindrical on saddles
Vertical Cylindrical with Dished bottom and flat top on Legs
Vertical Cylindrical with conical bottom and flat top on legsRectangular Tank with stiffeners
6
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Installation and minimum requirement of tanks
Legs of vertical tanks/Saddle of Horizontal Tanks should have a base beam in the skid frame
All tanks should have Ladder if height is more than 2mts and place near by Level gauge for easily access level gauge top nozzle valves
Man way should be in accessible area with appropriate elevation for easy access
All Tanks should have internal ladder
All Tanks should have minimum 2 no's of earth bosses
7
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Skid Frames
Skid should have a peripheral base frame for support all items in the skid
Skid should have internal supports/stiffeners maximum span of 900 mm for support grating
Skid should have minimum 4 Lifting Lug/ Trunnion support for lifting
Skid should have Minimum 2 No's of Earth Boss/Lug/cleat for Earthling
Skid should have Drip pan if asked by client (CS/SS upon client)
8
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Ladder hand rail and Platforms
Ladder and platforms are mandatory if anything need to access on top of the tank
All monkey ladder should have minimum width of 400 mm and distance between rungs should be 250 mm if client spec. not available
9
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Level Gauge and Level transmitters
Level gauge should be near to ladder and loading line
Level gauge drain valve should have sufficient height if it is connecting to common drain header
10
Level gauge should be near to ladder and loading line
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Tank Manway
All tanks should have Man way/Hand hole According to size of the tank/P&ID
Man way cover should be easily removable and ensure there is enough space for swing the man way cover with Davit
Man way should be placed near side wall of vertical tank for access the inside rungs ladder
11
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Goose Neck went with flame arrestor
Minimum 1 mts of height required for Gooseneck vent
If flame arrestor mentioned in the P&ID confirm with project s which type of Flame arrestor are going to use
12
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
PRV
All PRV should be installed top of the tanks
PRV. should be accessible for maintenance /calibration
PRV. Outlet line should be sloped towards tank nozzle for drain completely
13
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Return lines
14
All return lines should be neatly arranged and properly supported
All return lines should be sloped towards tank return nozzle for easy drain and any expansion in return line and if it is horizontal should use eccentric reducer only
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential 15
Loading lines
Loading lines should be neatly arranged and properly supported
Loading lines should be easily accessible elevation and near to Level gauge for clear view of filling
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Tank outlet valve should be accessible for easy operationTank outlet to pump reduction line reducer should be eccentricSuction line drain should be clear from obstructions of base frame
Suction line strainer should be in a convenient elevation and away from all obstruction for easy removal of filter and drain
16
Pump suction Lines
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Discharge/Injection Lines
17
Injection line valves should be easily accessible for operation
For easy operation and maintenance of pump no discharge line should be routed above the pump
All PD,PG,PRV&PT shall be Visible, accessible and have space for replacement
If required all the above said items shall be branched separately for easy operation and maintenance
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Discharge/Injection Lines
18
Prior to installing any Flow meter confirm whether this can be install horizontal/vertical
All Flow meters/Flow indicators shall be installed as per below mentioned rule
10D 5D
Flow meter
D=Id of pipe
MECHANICAL DESIGN&DRAFTING DEPT.
© 2009 Petronash. All rights reserved Petronash-Proprietary & Confidential
Miscellaneous
Loading pumps etc
19