characteristics data pmx-a series - kikusui · 2020. 12. 21. · standard referred to jis z8731 ....
TRANSCRIPT
![Page 1: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/1.jpg)
1
Characteristics Data
PMX-A Series
November 11, 2020
KIKUSUI ELECTRONICS CORP.
Ver.1.00
![Page 2: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/2.jpg)
2
CONTENTS
1. Output Ripple Voltage Waveform
2. Output Voltage Rising/Falling Waveform
3. Output Current Rising/Falling Waveform
4. Transient Response (1 kHz)
5. Power Consumption, Heat and Efficiency
6. Leakage Current (Protective Conductor Current)
7. Inrush Current Waveform
8. Noise
9. Output Voltage Rising/Falling Waveform by External Voltage Control
10. Output Current Rising/Falling Waveform by External Voltage Control
11. Output Voltage Rising/Falling Waveform under External Control
12. Output Current Rising/Falling Waveform under External Control
13. Input Resistance for External Analog Voltage Control
14. Bleeder Current (Sink Current)
15. Output Voltage with Remote Sensing Cable Disconnected
16. Inflow Current to Remote Sensing Terminal
17. Command Control Time (via RS232C interface)
18. Panel Display/Analog Control under Digital Remote Control
19. Voltage/Current Measurement Interval and Update Interval
20. Testing Circuit
21. List of Test Equipment
![Page 3: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/3.jpg)
3
Output Ripple Voltage Waveform
Temperature 25°C Model
Item
Condition
Testing Circuit Figure
A
Output Ripple Voltage
Waveform
Output voltage: 18 V, Output current: 5 A
Measured under the resistive load condition.
Oscilloscope: 20 MHz bandwidth
PMX18-5A
6mVp-p
![Page 4: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/4.jpg)
4
Output Ripple Voltage Waveform
Temperature 25°C Model
Item
Condition
Testing Circuit Figure
A
Output Ripple Voltage
Waveform
Output voltage: 250 V, Output current: 0.25 A
Measured under the resistive load condition.
Oscilloscope: 20 MHz bandwidth
PMX250-0.25A
6mVp-p
![Page 5: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/5.jpg)
5
Output Ripple Voltage Waveform
Temperature 25°C Model
Item
Condition
Testing Circuit Figure
A
Output Ripple Voltage
Waveform
Output voltage: 500 V, Output current: 0.1 A
Measured under the resistive load condition.
Oscilloscope: 20 MHz bandwidth
PMX500-0.1A
12.2mVp-p
![Page 6: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/6.jpg)
6
PMX18-5A Temperature 25°C Model
Item
Condition
Testing Circuit Figure
A
Output Voltage Rising/Falling
Waveform
Output voltage: 18 V, Output current: Max.
Measured when the output was turned on and off under no load
condition.
Output Voltage Rising Waveform
Output Voltage Falling Waveform
![Page 7: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/7.jpg)
7
PMX18-5A Temperature 25°C Model
Item
Condition
Testing Circuit Figure
A
Output Voltage Rising/Falling
Waveform
Output voltage: 18 V, Output current: Max.
Measured when the output was turned on and off under the
rated load (resistive load) condition.
Output Voltage Rising Waveform
Output Voltage Falling Waveform
![Page 8: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/8.jpg)
8
PMX250-0.25A Temperature 25°C Model
Item
Condition
Testing Circuit Figure
A
Output Voltage Rising/Falling
Waveform
Output voltage: 250 V, Output current: Max.
Measured when the output was turned on and off under no load condition.
*PMX250-0.25A has the equivalent performance of PMX110-0.6A.
Output Voltage Rising Waveform
Output Voltage Falling Waveform
![Page 9: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/9.jpg)
9
PMX250-0.25A Temperature 25°C Model
Item
Condition
Testing Circuit Figure
A
Output Voltage Rising/Falling
Waveform
Output voltage: 200 V and 150 V, Output current: Max.
Measured when the output was turned on and off under no load condition.
*PMX250-0.25A has the equivalent performance of PMX110-0.6A.
Output Voltage Rising Waveform: Output Voltage: 200 V
Output Voltage Falling Waveform: Output Voltage: 150 V
![Page 10: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/10.jpg)
10
PMX250-0.25A Temperature 25°C Model
Item
Condition
Testing Circuit Figure
A
Output Voltage Falling
Waveform
Output voltage: 100 V and 50 V, Output current: Max. Measured when the
output was turned on and off under the rated load (resistive load) condition.
*PMX250-0.25A has the equivalent performance of PMX110-0.6A.
Output Voltage Falling Waveform Output Voltage: 100 V
Output Voltage Falling Waveform Output Voltage: 50 V
![Page 11: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/11.jpg)
11
PMX250-0.25A Temperature 25°C Model
Item
Condition
Testing Circuit Figure
A
Output Voltage Rising/Falling
Waveform
Output voltage: 250 V, Output current: Max.
Measured when the output was turned on and off under the
rated load (resistive load) condition.
.
Output Voltage Rising Waveform
Output Voltage Falling Waveform
![Page 12: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/12.jpg)
12
PMX500-0.1A Temperature 25°C Model
Item
Condition
Testing Circuit Figure
A
Output Voltage Rising/Falling
Waveform
Output voltage: 500 V, Output current: Max.
Measured when the output was turned on and off under no load
condition.
.
Output Voltage Rising Waveform
Output Voltage Falling Waveform
![Page 13: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/13.jpg)
13
PMX500-0.1A Temperature 25°C Model
Item
Condition
Testing Circuit Figure
A
Output Voltage Rising/Falling
Waveform
Output voltage: 500 V, Output current: Max.
Measured when the output was turned on and off under the
rated load (resistive load) condition.
Output Voltage Rising Waveform
Output Voltage Falling Waveform
![Page 14: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/14.jpg)
14
PMX18-5A Temperature
25°C Model
Item
Condition
Testing Circuit
Figure
A
Output Current Rising/Falling
Waveform
Output voltage: 18 V, Output current: 5 A
Measured when the output was turned on and off with the output
short-circuited. CC mode was prioritized when the output was turned on.
Output Current Rising Waveform
Output Current Falling Waveform
![Page 15: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/15.jpg)
15
PMX18-5A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Output Current Rising Waveform,
CV Mode Prioritized
Output voltage: 18 V, Output current: 5 A
Measured when the output was turned on and off with the output
short-circuited. CV mode was prioritized when the output was turned on.
Output Current Rising Waveform: CV Mode Prioritized
![Page 16: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/16.jpg)
16
PMX18-5A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Output Current Rising/Falling
Waveform
Output voltage: Max., Output current: 5 A
Measured when the output was turned on and off under the rated load (resistive
load) condition. CC mode was prioritized when the output was turned on.
Output Current Rising Waveform
Output Current Falling Waveform
![Page 17: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/17.jpg)
17
PMX250-0.25A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Output Current Rising/Falling
Waveform
Output voltage: 250 V, Output current: 0.25 A
Measured when the output is turned on and off with the output
short-circuited. CC mode is prioritized when the output is turned on.
Output Current Rising Waveform
Output Current Falling Waveform
![Page 18: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/18.jpg)
18
PMX250-0.25A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Output Current Rising Waveform,
CV Mode Prioritized
Output voltage: 250 V, Output current: 0.25A
Measured when the output is turned on and off with the output
short-circuited. CV mode is prioritized when the output is turned on.
Output Current Rising Waveform: CV Mode Prioritized
![Page 19: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/19.jpg)
19
PMX250-0.25A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Output Current Rising/Falling
Waveform
Output voltage: Max., Output current: 0.25A
Measured when the output is turned on and off under the rated load
(resistive load). CC mode is prioritized when the output is turned on.
Output Current Rising Waveform
Output Current Falling Waveform
![Page 20: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/20.jpg)
20
PMX500-0.1A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Output Current Rising/Falling
Waveform
Output voltage: 500 V, Output current: 0.1A
Measured when the output is turned on and off with the output
short-circuited. CC mode is prioritized when the output is turned on.
Output Current Rising Waveform
Output Current Falling Waveform
![Page 21: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/21.jpg)
21
PMX500-0.1A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Output Current Rising Waveform,
CV Mode Prioritized
Output voltage: 500 V, Output current: 0.1 A
Measured when the output is turned on and off with the output
short-circuited. CV mode is prioritized when the output is turned on.
Output Current Rising Waveform: CV Mode Prioritized
![Page 22: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/22.jpg)
22
PMX500-0.1A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Output Current Rising/Falling
Waveform
Output voltage: Max., Output current: 0.1 A
Measured when the output is turned on and off under the rated load
(resistive load). CC mode is prioritized when the output is turned on.
Output Current Rising Waveform
Output Current Falling Waveform
![Page 23: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/23.jpg)
23
PMX18-5A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Transient Response (1 kHz)
Output voltage: 18 V, Output current: Max.
E-load condition: PLZ1004W (CC mode, slew rate: 1600 mA/us,
M-range, D = 50%)
Transient Response: 10% - 100% change in load current
Output Voltage
Output Current
![Page 24: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/24.jpg)
24
PMX18-5A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Transient Response (1 kHz)
Output voltage: 18 V, Output current: Max.
E-load condition: PLZ1004W (CC mode, slew rate: 1600 mA/us,
M-range, D = 50%)
Enlarged View of Transient Response: 10% - 100% change in load current
Output Voltage
Output Current
Enlarged View of Transient Response: 10% - 100% change in load current
Output Voltage
Output Current
![Page 25: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/25.jpg)
25
PMX250-0.25A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Transient Response (1 kHz)
Output voltage: 250 V, Output current: Max.
E-load condition: PLZ164WH (CC mode, slew rate: 13.2 mA/us,
M-range, D = 50%)
Transient Response: 10% - 100% change in load current
Output Voltage
Output Current
![Page 26: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/26.jpg)
26
PMX250-0.25A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Transient Response (1 kHz)
Output voltage: 250 V, Output current: Max.
E-load condition: PLZ164WH (CC mode, slew rate: 13.2 mA/us,
M-range, D = 50%)
Enlarged View of Transient Response: 10% - 100% change in load current
Output Voltage
Output Current
Enlarged View of Transient Response: 10% - 100% change in load current
Output Voltage
Output Current
![Page 27: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/27.jpg)
27
PMX500-0.1A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Transient Response (1 kHz)
Output voltage: 500 V, Output current: Max.
E-load condition: PLZ164WH (CC mode, slew rate: 13.2 mA/us,
M-range, D = 50%)
Transient Response: 10% - 100% change in load current
Output Voltage
Output Current
![Page 28: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/28.jpg)
28
PMX500-0.1A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Transient Response (1 kHz)
Output voltage: 500 V, Output current: Max.
E-load condition: PLZ164WH (CC mode, slew rate: 13.2 mA/us,
M-range, D = 50%)
Enlarged View of Transient Response: 10% - 100% change in load current
Output Voltage
Output Current
Enlarged View of Transient Response: 10% - 100% change in load current
Output Voltage
Output Current
![Page 29: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/29.jpg)
29
PMX18-5A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
B
Power Consumption, Heat and
Efficiency
Input voltage: 100 Vac and 217 Vac
Output voltage: 18 V, Output current: See below.
Power Consumption, Heat and Efficiency
![Page 30: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/30.jpg)
30
PMX250-0.25A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
B
Power Consumption, Heat and
Efficiency
Input voltage: 100 Vac and 217 Vac
Output voltage: 250 V, Output current: See below.
Power Consumption, Heat and Efficiency
![Page 31: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/31.jpg)
31
PMX500-0.1A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
B
Power Consumption, Heat and
Efficiency
Input voltage: 100 Vac and 217 Vac
Output voltage: 500 V, Output current: See below.
Power Consumption, Heat and Efficiency
![Page 32: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/32.jpg)
32
PMX18-5A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
C
Leakage Current (Protective
Conductor Current)
Measured when PMX18-5A was powered on and in the stand-by
state.
LC meter: TOS3200
PMX18-5A: Leakage Current
Lea
kag
e C
urr
en
t (m
A)
Input voltage (V)
![Page 33: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/33.jpg)
33
PMX18-5A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
D
Inrush Current Waveform
Input voltage: 110 Vac, Frequency: 50 Hz
Input phase: 0°-off, 180°-on
Input power source: PCR2000LA
Inrush Current Waveform
Input AC Voltage
Input AC Current
![Page 34: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/34.jpg)
34
Noise Level
Fan speed: fastest No load
Front side 48 dB 37 dB
Left side 48 dB 36 dB
Rear side 53 dB 38 dB
Right side 47 dB 36 dB
Top side 46 dB 32 dB
PMX-A Series Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
A
Noise
Measured when PMX-A series was powered on and in the stand-by
state under no load condition. The fan was set to fastest.
Noise meter: SOUND LEVEL METER 3604
Standard referred to JIS Z8731
![Page 35: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/35.jpg)
35
PMX18-5A Temperature
25°C Model
Item
Condition
Testing Circuit
Figure
E
Output current: Max.
Measured under no load condition.
Applied the external voltage at 10 V (J1, Pin 4 and 5).
Output Voltage Rising Waveform
Output Voltage Falling Waveform
Output Voltage
External Voltage
Output Voltage
External Voltage
Output Voltage Rising/Falling Waveform
by External Voltage Control
![Page 36: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/36.jpg)
36
Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
E
Output voltage:18 V
Measured with the output short-circuited.
Applied the external voltage at 10 V (J1, Pin 14 and 15).
Output Current
External Voltage
Output Current
PMX18-5A
Output Current Rising/Falling Waveform
by External Voltage Control
Output Current Rising Waveform
Output Current Falling Waveform
External Voltage
![Page 37: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/37.jpg)
37
PMX18-5A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
F
Output voltage: 18 V, Output current: Max. Measured when the output was
turned on and off under external control and no load condition (Repeated the
measurements a few dozen times via J1 Pin 18 and 19).
Output Voltage Rising Waveform
Output Voltage
External Signal
Output Voltage Falling Waveform
Output Voltage
External Signal
Output Voltage Rising/Falling
Waveform under External Control
![Page 38: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/38.jpg)
38
PMX18-5A Temperature
25°C Model
Item
Condition
Testing Circuit
Figure
F
Output voltage: 18 V, Output current: 5 A, Measured when the output was
turned on and off under external control with the output short-circuited
(Repeated the measurements a few dozen times via J1 Pin 18 and 19).
Output Current Rising/Falling
Waveform under External Control
External Signal
Output Current Rising Waveform
Output Current
External Signal
Output Current Falling Waveform
Output Current
![Page 39: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/39.jpg)
39
PMX-A Series
Temperature
-
Model
Item
Condition
Testing Circuit
-
-
Input Resistance for External
Analog Voltage Control
Input resistance for EXT-V CV CONT/EXT-V CC CONT:
approx. 25 kΩ to 26 kΩ
20kΩ
5.1kΩ
1kΩ
EXT-V CV CONT
EXT-V CC CONT
![Page 40: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/40.jpg)
40
PMX-A Series Temperature
- Model
Item
Condition
Testing Circuit
-
See the following excerpt from user’s manual.
Bleeder Current (Sink Current)
![Page 41: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/41.jpg)
41
Output voltage measurement when remote sensing circuit was open
Model PMX18-5A PMX35-3A
Local Sensing 18.00 V 35.00 V
Remote sensing
circuit was open
Sensing terminal (+S) was open.
18.37 V Sensing terminal (+S) was open.
36.01 V
Sensing terminal (-S) was open.
18.11 V Sensing terminal (-S) was open.
35.38 V
Both terminals (+S/-S) were open.
18.48 V Both terminals (+S/-S) were open.
36.41 V
PMX18-5A、PMX35-3A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
G
Output voltage: 18 V and 35 V
Measured under no load condition while the remote sensing
function was turned on but the remote sensing circuit was open.
Output Voltage with Remote
Sensing Cable Disconnected
![Page 42: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/42.jpg)
42
Model Output Voltage Inflow Current
PMX18-2A 18 V 0.44 mA PMX18-5A 18 V 0.44 mA PMX35-1A 35 V 0.44 mA PMX35-3A 35 V 0.44 mA
PMX-A Series
Temperature
-
Model
Item
Condition
Testing Circuit
-
The table below shows the design reference values.
Inflow Current to Remote
Sensing Terminal
![Page 43: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/43.jpg)
43
PMX18-5A Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
H
Output voltage: 18 V, Output current: Max. Measured the time length from issuing the command to rising or falling the output voltage under no load condition (Repeated the measurements a few dozen times). Baudrate: 19200bps
Command Control Time (via
RS232C interface)
Command: OUTP 1
Control time: Approx. 238 ms
Command: OUTP 0
Control time: Approx. 300 ms
OUTP 1
OUTP 0
![Page 44: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/44.jpg)
44
PMX18-5A Temperature
25°C Model
Item
Condition
Testing Circuit
Figure
H
Output voltage: 18 V, Output current: Max. Measured the time length from issuing the command to rising or falling the output voltage under no load condition (Repeated the measurements a few dozen times). Baudrate: 19200bps
Command Control Time (via
RS232C interface)
Command: VOLT 18
Control time: Approx. 158 ms
Command: VOLT 0
Control time: Approx. 342 ms
VOLT 18
VOLT 0
![Page 45: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/45.jpg)
45
PMX18-5A
Temperature
25°C
Model
Item
Condition
Testing Circuit
Figure
H
Output voltage: 18 V, Output current: Max.
Measured the response time for the command under no load condition.
Baudrate: 19200bps
Command Response Time (via
RS232C interface)
Command: MEAS:VOLT?
Response time Approx. 23 ms MEAS:VOLT?
![Page 46: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/46.jpg)
46
Model PMX-A Series
Remote Control
Status REMOTE LED lights.
REMOTE
Command
USB: Move to remote control by any command.
RS232C/LAN: Send REMOTE command first. (Once
REMOTE command has been transmitted, any command is
accepted.)
Remote Control
Cancel
Press LOCAL.
(or turn off and on POWER.)
Panel Operation Invalid
(including OUTPUT on/off)
Analog Control
Analog control is prioritized.
For the output on/off, analog output off is prioritized. Under
the analog output off state, by sending the OUTPUT-ON
command (via USB interface), PMX-A does not turn the
output on but enters the remote mode.
If changing voltage or current value by panel operation or
command under analog control, such change is applied after
cancelling analog control (Internal reference setting has been
changed). Voltage or current change by command is not
accepted under analog control.
*IDN?
Identify information of PMX-A: model name, serial number,
IFC version, IFC build number, IOC version and IOC build
number.
(E.g. KIKUSUI,PMX18-5A,A141A005,IFC01.10.0033
PMX-A Series
Temperature
25°C Model
Item
Condition
Testing Circuit
Figure
H
Under no load condition
Panel Display/Analog Control
under Digital Remote Control
![Page 47: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/47.jpg)
47
IOC01.10.0065)
PMX-A Series
Voltage/current measurement interval 100-500 ms
Update interval for panel/communication interface 24 ms
PMX-A Series Temperature
-
Model
Item
Condition
Testing Circuit
-
The table below shows the design reference values.
Voltage/Current Measurement
Interval and Update Interval
![Page 48: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/48.jpg)
48
Voltage
FG
Testing Circuit
Current
Electronic DC Load
or
Resistive Load
Power Supply
Oscilloscope
Figure A
Figure C
Power Supply
Leakage Current
Tester
Figure B
Electronic DC Load
or
Resistive Load
Power Supply Power
Meter
AC
Power
Supply
![Page 49: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/49.jpg)
49
Voltage
Voltage
EXT Voltage
Voltage
External Signal
Testing Circuit
Figure D
Current
Electronic DC Load
or
Resistive Load
Power Supply
Oscilloscope
AC
Power
Supply
Current
Electronic DC Load
or
Resistive Load
Oscilloscope
Figure E
External Power
Supply
Power Supply
Current
Electronic DC Load
or
Resistive Load
Oscilloscope
Figure F
External Signal
PBZ40-10
Power Supply
![Page 50: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/50.jpg)
50
Voltage
Serial data
Testing Circuit
Electronic DC Load
or
Resistive Load
Oscilloscope
Figure H
PC (RS232C)
Power Supply
Power Supply
+S
-S
+V
-V
Figure G
![Page 51: Characteristics Data PMX-A Series - KIKUSUI · 2020. 12. 21. · Standard referred to JIS Z8731 . 35 PMX18-5A Temperature Model 25°C Item Condition Testing Circuit Figure E Output](https://reader035.vdocuments.mx/reader035/viewer/2022071513/61343604dfd10f4dd73b95ec/html5/thumbnails/51.jpg)
51
Test Equipment Model No. Manufacturer
Oscilloscope DPO3014, TDS3012
MSO2002B
Tektronix, Inc.
Current Probe TCPA300, TCP303
TCP202
Tektronix, Inc.
High-Voltage Probe P5100A Tektronix, Inc.
Power Meter WT230 Yokogawa Electric
Corporation
Multi-meter Equivalent to DME1600 Kikusui Electronics
Corp.
Electronic Load PLZ1004W
PLZ1004WH
Kikusui Electronics
Corp.
Leakage Current
Tester
TOS3200 Kikusui Electronics
Corp.
AC Power Supply PCR6000LE2 Kikusui Electronics
Corp.
Sound Level Meter 3604 Yokogawa Electric
Corporation
Bi-polar Power Supply PBZ40-10 Kikusui Electronics
Corp.
List of Test Equipment