characteristics contactors - rs components · 2019. 10. 13. · lc p -k06, lp p -k06, lc p -k09, lp...

44
2/18 2 2.2 Contactors Contactors and reversing contactors types LCp-K and LPp-K Environment Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1, NF C 63-110, VDE 0660 Approvals LCp and LPp-K06 to K12 UL, CSA, DEMKO, NEMKO, SEMKO, FI Operating positions Vertical axis Horizontal axis Without derating Without derating Possible positions for LCp-K only. Contactor energisation voltage: 0.85 Uc Max to Cabling Min Max IEC/EN 60947 Screw clamp connections Solid conductor mm 2 1 x 1.5 2 x 4 1 x 4 + 1 x 2.5 Flexible cable without cable end mm 2 1 x 0.75 2 x 4 2 x 2.5 Flexible cable with cable end mm 2 1 x 0.34 1 x 1.5 + 1 x 2.5 1 x 1.5 + 1 x 2.5 Spring terminal connections Solid conductor mm 2 1 x 0.75 1 x 1.5 2 x 1.5 Flexible conductor without cable end mm 2 1 x 0.75 1 x 1.5 2 x 1.5 Faston connectors Clip mm 2 x 2.8 or 1 x 6.35 Solder pins for With locating device between power printed circuit board and control circuits 4 mm x 35 microns Tightening torque Philips head n˚ 2 and Ø 6 N.m 0.8…1.3 Terminal referencing Conforming to standards EN 50005 and EN 50012 Up to 5 contacts Rated insulation voltage (Ui) Conforming to IEC/EN 60947-4-1 V 690 Conforming to VDE 0110 gr C V 750 Conforming to NF C 20-040 V 690 Conforming to CSA 22-2 n˚ 14, UL 508 V 600 Rated impulse withstand voltage (Uimp) kV 8 Protective treatment Conforming to IEC 68 (DIN 50016) “TC” (Klimafest, Climateproof) Degree of protection Conforming to VDE 0106 Protection against direct finger contact Ambient air temperature Storage ˚C - 50…+ 80 around the device Operation ˚C - 25…+ 50 Maximum operating altitude Without derating m 2000 Vibration resistance Contactor open 2 gn 5 ... 300 Hz Contactor closed 4 gn Flame resistance Conforming to UL 94 Self-extinguishing materials V1 Conforming to NF F 16-101 and 16-102 Conforming to requirement 2 Shock resistance Contactor open 10 g (1/2 sine wave, 11 ms) Contactor closed 15 g Safe circuit separation Conforming to VDE 0106 and IEC 536 VLSV (Very Low Safety voltage), up to 400 V Characteristics Selection: pages 1/14 to 1/37 References: pages 2/22 to 2/35 Dimensions: pages 2/40 and 2/42 Schemes: pages 2/41 and 2/43 1 8 0

Upload: others

Post on 17-Sep-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/18

2

2.2

ContactorsContactors and reversing contactorstypes LCp-K and LPp-K

Environment

Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1, NF C 63-110, VDE 0660

Approvals LCpppp and LPpppp-K06 to K12 UL, CSA, DEMKO, NEMKO, SEMKO, FI

Operating positions Vertical axis Horizontal axis

Without derating Without derating Possible positions for LCp-K only. Contactor energisation voltage: 0.85 Uc

Max toCabling Min Max IEC/EN 60947

Screw clamp connections Solid conductor mm2 1 x 1.5 2 x 4 1 x 4 + 1 x 2.5

Flexible cable without cable end mm2 1 x 0.75 2 x 4 2 x 2.5

Flexible cable with cable end mm2 1 x 0.34 1 x 1.5 + 1 x 2.5 1 x 1.5 + 1 x 2.5

Spring terminal connections Solid conductor mm2 1 x 0.75 1 x 1.5 2 x 1.5Flexible conductor without cable end mm2 1 x 0.75 1 x 1.5 2 x 1.5

Faston connectors Clip mm 2 x 2.8 or 1 x 6.35

Solder pins for With locating device between powerprinted circuit board and control circuits 4 mm x 35 microns

Tightening torque Philips head n˚ 2 and Ø 6 N.m 0.8…1.3

Terminal referencing Conforming to standards EN 50005 and EN 50012 Up to 5 contacts

Rated insulation voltage (Ui) Conforming to IEC/EN 60947-4-1 V 690

Conforming to VDE 0110 gr C V 750

Conforming to NF C 20-040 V 690

Conforming to CSA 22-2 n˚ 14, UL 508 V 600

Rated impulse withstand voltage(Uimp)

kV 8

Protective treatment Conforming to IEC 68 (DIN 50016) “TC” (Klimafest, Climateproof)

Degree of protection Conforming to VDE 0106 Protection against direct finger contact

Ambient air temperature Storage ˚C - 50…+ 80around the device

Operation ˚C - 25…+ 50

Maximum operating altitude Without derating m 2000

Vibration resistance Contactor open 2 gn5 ... 300 Hz

Contactor closed 4 gn

Flame resistance Conforming to UL 94 Self-extinguishing materials V1

Conforming to NF F 16-101 and 16-102 Conforming to requirement 2

Shock resistance Contactor open 10 g(1/2 sine wave, 11 ms)

Contactor closed 15 g

Safe circuit separation Conforming to VDE 0106 and IEC 536 VLSV (Very Low Safety voltage), up to 400 V

Characteristics

Selection:pages 1/14 to 1/37

References:pages 2/22 to 2/35

Dimensions:pages 2/40 and 2/42

Schemes:pages 2/41 and 2/43

180

Page 2: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/19

2

2.2

ContactorsContactors and reversing contactorstypes LCp-K and LPp-K

Pole characteristics

Conventional thermal current (Ith) For ambient temperature ≤ 50 ˚C A 20

Rated operational frequency Hz 50/60

Frequency limits ofoperational current Hz Up to 400

Rated operational voltage (Ue) V 690

Rated making capacity I rms to NF C 63-110 and IEC/EN 60947-4-1LCpppp-K06, LPpppp-K06, LCpppp-K09, LPpppp-K09 A 110LCpppp-K12, LPpppp-K12 A 144

Rated breaking capacity V 220/ 380/ 415 440 500 660/240 400 690

I rms to NF C 63-110 and IEC/EN 60947-4-1LCpppp-K06, LPpppp-K06, LCpppp-K09, LPpppp-K09 A 110 110 110 110 80 70LCpppp-K12, LPpppp-K12 A – – – 110 80 70

Permissible short time rating In free air for a time “t” 1 s 5 s 10 s 30 s 1 min 3 min ≥ 15 minfrom cold state (θ ≤ 50 ˚C)

LCpppp-K06, LPpppp-K06, LCpppp-K09, LPpppp-K09 A 90 85 80 60 45 40 20LCpppp-K12, LPpppp-K12 A 115 105 100 75 55 50 25

Short-circuit protection gG fuse U ≤ 440 V (aM fuse, see page 2/46) A 25

Average impedance per pole At Ith and 50 Hz mΩ 3

Utilisation in category AC-1 Maximum rated operational current A 20resistive circuits, heating, lighting for a temperature ≤ 50 ˚C(Ue ≤ 440 V)

Maximum rated operational current A 16 for Ue onlyfor a temperature ≤ 70 ˚C

Rated operational current limits in relation A On-load factor 90% 60 % 30 %to on-load factor and operating frequency

300 op. cycles/hour 13 15 18

120 op. cycles/hour 15 18 19

30 op. cycles/hour 19 20 20

Increase in operational current Apply the following coefficients to the current valuesby paralleling of poles above. These take into account the often

unbalanced current distribution between poles

2 poles in parallel: K = 1.60

3 poles in parallel: K = 2.25

4 poles in parallel: K = 2.80

Utilisation in category AC-3 Operational powersquirrel cage motors according to the voltage Voltage 50 or 60 Hz V 115 220 220/ 380/ 440/ 500/ 660/

240 415 480 600 6901-ph 1-ph 3-ph 3-ph 3-ph 3-ph 3-ph

LCpppp-K06, LPpppp-K06 kW 0.37 0.75 1.5 2.2 3 3 3

LCpppp-K09, LPpppp-K09 kW 0.55 1.1 2.2 4 4 4 4

LCpppp-K12, LPpppp-K12 kW – – 3 5.5 5.5/ 4 44 (480)

% utilisation of operational power in relation Op. cycles/hr 600 900 1200to the maximum operating rate

Power 100% 75% 50%

Characteristics

Selection:pages 1/14 to 1/37

References:pages 2/22 to 2/35

Dimensions:pages 2/40 and 2/42

Schemes:pages 2/41 and 2/43

Page 3: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/20

2

2.2

ContactorsContactors and reversing contactorstypes LCp-K and LPp-K

(1) For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC(50…129 V) or LAF-KE1UG (130…250 V), see page 2/38.

Control circuit characteristics

Contactor type LC1 LC2 LC7 LC8 LP1 LP2

Rated control circuit voltage (Uc) V a 12…690 (1) a 24…240 c 12…250 (1)

Control voltage limits Operation 0.8…1.15 Uc 0.85…1.1 Uc 0.8…1.15 Uc(≤ 50 ˚C) single voltage coil

Drop-out ≥ 0.20 Uc ≥ 0.10 Uc ≥ 0.10 Uc

Average consumption Inrush 30 VA 3 VA 3 Wat 20 ˚C and at Uc

Sealed 4.5 VA 3 VA 3 W

Heat dissipation W 1.3 3 3

Operating time Between coil energisation and:at 20 ˚C and at Uc - opening of the N/C contacts ms 5…15 25…35 25…35

- closing of the N/O contacts ms 10…20 30…40 30…40

Between coil de-energisation and:- opening of the N/O contacts ms 10…20 30 10- closing of the N/C contacts ms 15…25 40 15

Maximum immunity tomicro-breaks ms 2 2 2

Maximum operating rate In operating cycles per hour 3600 3600 3600

Mechanical durability at Uc 50/60 Hz coil 10 5 10 5 – –In millions of operating cycles

c coil – – – – 10 5

Characteristics (continued)

Selection:pages 1/14 to 1/37

References:pages 2/22 to 2/35

Dimensions:pages 2/40 and 2/42

Schemes:pages 2/41 and 2/43

Page 4: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/21

2

2.2

10 000

5000

3000

2000

1000800600500400300

200

1008060

24 48 110 220

440 690 V120

380 50040

16 000

80006000

4000

2c2b

4

1

2a

1000

700

500

300

200

1008060504030

20

1086

12 24 48 110 220 440 600 V

250

200

140

100

50

20

2c

2b

2a

3

4

Characteristics of contactor auxiliary contacts and instantaneous contact blocks

Number of auxiliary contacts On LCp-K or LPp-K 1

On LA1-K 2 or 4

Rated operational voltage (Ue) Up to V 690

Rated insulation voltage (Ui) Conforming to IEC/EN 60947-4-1 V 690

Conforming to VDE 0110 group C V 750

Conforming to CSA C 22-2 n˚ 14 V 600

Conventional thermal current (lth) For ambient temperature ≤ 50 ˚C A 10

Frequency of operational current Hz Up to 400

Minimum switching capacity U min (DIN 19 240) V 17 (2 < 10-3)

I min mA 5

Short-circuit protection Conforming to IEC/EN 60947-4-1 and VDE 0660, A 10gG fuse

Rated making capacity Conforming to IEC/EN 60947-4-1 I rms A 110

Overload current Permissible for 1 s A 80

500 ms A 90

100 ms A 110

Insulation resistance MΩ > 10

Non-overlap distance LA1-K: linked contacts to INRS, BIA and CNA specs. mm 0.5 (see schemes, pages 2/41 and 2/43)

Operational power of contacts a.c. supply, category AC-15 d.c. supply, category DC-13conforming to IEC/EN 60947 Electrical durability (valid up to 3600 operating cycles

per hour) on an inductive load such as the coil of anelectromagnet: making current (cos ϕ 0.7) = 10 times the breaking current (cos ϕ 0.4).

1 million operating cycles3 million operating cycles10 million operating cyclesOccasional making capacity

1 Breaking limit of contacts valid for:- maximum of 50 operating cyclesat 10 s intervals(breaking current = making currentx cos ϕ 0.7).

2 Electrical durability of contacts for:- 1 million operating cycles (2a)-3 million operating cycles (2b)-10 million operating cycles (2c).

3 Breaking limit of contacts valid for:- maximum of 20 operating cyclesat 10 s intervals with current passingfor 0.5 s per operating cycle.

4 Thermal limit.

ContactorsContactors and reversing contactorstypes LCp-K and LPp-K

Characteristics

Selection:pages 1/14 to 1/37

References:pages 2/22 to 2/35

Dimensions:pages 2/40 and 2/42

Schemes:pages 2/41 and 2/43

110/ 220/ 380/ 600/V 24 48 127 230 400 440 690VA 48 96 240 440 800 880 1200VA 17 34 86 158 288 317 500VA 7 14 36 66 120 132 200VA 1000 2050 5000 10 000 14 000 13 000 9000

Electrical durability (valid up to 1200 operating cycles perhour), on an inductive load such as the coil of an electro-magnet, without economy resistor, the time constantincreasing with the load.

V 24 48 110 220 440 600W 120 80 60 52 51 50W 55 38 30 28 26 25W 15 11 9 8 7 6W 720 600 400 300 230 200

Tim

e co

nsta

ntin

mill

isec

onds

Power broken in VA Power broken in W

Page 5: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/22

2

2.2

- Contactor selection according to the utilisation category, see the Technical & Application guide available atwww.schneider.co.uk.- Mounting on 35 mm 7 rail or Ø 4 screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.

(1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Contactors LC1K (0.8…1.15 Uc) (0.85…1.1 Uc)

Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72(2) For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC(50…129 V) or LA4-KE1UG (130…250 V), see page 2/38.

3-pole general purpose contactors

Standard power ratings Rated Instantaneous Basic reference. Weightof 3-phase motors operational auxiliary Complete with code50/60 Hz in category voltage contacts indicating controlAC-3 in AC-3 circuit voltage (1) (2)

up to220 V 380 V 440/500 V 440 V240 V 415 V 660/690 VkW kW kW A N/O N/C kg

Screw clamp connections

1.5 2.2 3 6 1 – LC1-K0610pppppppp 0.180

– 1 LC1-K0601pppppppp 0.180

2.2 4 4 9 1 – LC1-K0910pppppppp 0.180

– 1 LC1-K0901pppppppp 0.180

3 5.5 4 (> 440) 12 1 – LC1-K1210pppppppp 0.1805.5 (440)

– 1 LC1-K1201pppppppp 0.180

Spring terminal connections

1.5 2.2 3 6 1 – LC1-K06103pppppppp 0.180

– 1 LC1-K06013pppppppp 0.180

2.2 4 4 9 1 – LC1-K09103pppppppp 0.180

– 1 LC1-K09013pppppppp 0.180

3 5.5 4 (> 440) 12 1 – LC1-K12103pppppppp 0.1805.5 (440)

– 1 LC1-K12013pppppppp 0.180

Volts a 12 20 24(3) 36 42 48 110 115 120 127 200/ 220/ 230 230/ 256 277 380/ 40050/60 Hz 208 230 240 400Code J7 Z7 B7 C7 D7 E7 F7 FE7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7Volts a 400/ 440 480 500 575 600 660/50/60 Hz 415 690Code N7 R7 T7 S7 SC7 X7 Y7

ContactorsContactors for motor control, 6 to 12 A in utilisation category AC-3 Control circuit: a.c.

References

LC1-K0610pp

Selection:pages 1/16 to 1/23

Characteristics:pages 2/18 to 2/21

Dimensions:page 2/40

Schemes:page 2/41

a

LC1-K09103pp

Page 6: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/23

2

2.2

- Contactor selection according to the utilisation category, see the Technical & Application guide available atwww.schneider.co.uk - Mounting on 35 mm 7 rail or Ø 4 screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.

(1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Contactors LC1K (0.8…1.15 Uc) (0.85…1.1 Uc)

Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72(2) For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC(50…129 V) or LA4-KE1UG (130…250 V), see page 2/38.

3-pole general purpose contactors

Standard power ratings Rated Instantaneous Basic reference. Weightof 3-phase motors operational auxiliary Complete with code50/60 Hz in category voltage contacts indicating controlAC-3 in AC-3 circuit voltage (1) (2)

up to220 V 380 V 440/500 V 440 V240 V 415 V 660/690 VkW kW kW A N/O N/C kg

Faston connectors, 1 x 6.35 or 2 x 2.8

1.5 2.2 3 6 1 – LC1-K06107pppppppp 0.180

– 1 LC1-K06017pppppppp 0.180

2.2 4 4 9 1 – LC1-K09107pppppppp 0.180

– 1 LC1-K09017pppppppp 0.180

3 5.5 4 (> 440) 12 1 – LC1-K12107pppppppp 0.1805.5 (440)

– 1 LC1-K12017pppppppp 0.180

Solder pins for printed circuit boards

1.5 2.2 3 6 1 – LC1-K06105pppppppp 0.210

– 1 LC1-K06015pppppppp 0.210

2.2 4 4 9 1 – LC1-K09105pppppppp 0.210

– 1 LC1-K09015pppppppp 0.210

3 5.5 4 (> 440) 12 1 – LC1-K12105pppppppp 0.2105.5 (440)

– 1 LC1-K12015pppppppp 0.210

Volts a 12 20 24(3) 36 42 48 110 115 120 127 200/ 220/ 230 230/ 256 277 380/ 40050/60 Hz 208 230 240 400Code J7 Z7 B7 C7 D7 E7 F7 FE7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7Volts a 400/ 440 480 500 575 600 660/50/60 Hz 415 690Code N7 R7 T7 S7 SC7 X7 Y7

ContactorsContactors for motor control, 6 to 12 A in utilisation category AC-3Control circuit: a.c.

References

LC1-K06107pp

LC1-K06105pp

Selection:pages 1/16 to 1/23

Characteristics:pages 2/18 to 2/21

Dimensions:page 2/40

Schemes:page 2/41

a

Page 7: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/24

2

2.2

Recommended for use in areas sensitive to noise, high interference mains supplies, etc.

- Contactor selection according to utilisation category, see the Technical & Application guide available atwww.schneider.co.uk.- Coil with rectifier incorporated, suppressor fitted as standard.- Mounting on 35 mm 7 rail or Ø 4 screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.

(1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Contactors LC7-K (0.85…1.1 Uc)

(2) For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC(50…129 V) or LA4-KE1UG (130…250 V), see page 2/38.

3-pole contactors for use in sensitive environments

Standard power ratings Rated Instantaneous Basic reference. Weightof 3-phase motors opera- auxiliary Complete with code50/60 Hz in category tional contacts indicating controlAC-3 current circuit voltage (1) (2)

in AC-3220 V 380 V 440/500 V up to240 V 415 V 660/690 V 440 VkW kW kW A N/O N/C kg

Screw clamp connections

1.5 2.2 3 6 1 – LC7-K0610pppppppp 0.225

– 1 LC7-K0601pppppppp 0.225

2.2 4 4 9 1 – LC7-K0910pppppppp 0.225

– 1 LC7-K0901pppppppp 0.225

3 5.5 4 (> 440) 12 1 – LC7-K1210pppppppp 0.2255.5 (440)

– 1 LC7-K1201pppppppp 0.225

Faston connectors, 1 x 6.35 or 2 x 2.8

1.5 2.2 3 6 1 – LC7-K06107pppppppp 0.225

– 1 LC7-K06017pppppppp 0.225

2.2 4 4 9 1 – LC7-K09107pppppppp 0.225

– 1 LC7-K09017pppppppp 0.225

3 5.5 4 (> 440) 12 1 – LC7-K12107pppppppp 0.2255.5 (440)

– 1 LC7-K12017pppppppp 0.225

Solder pins for printed circuit boards

1.5 2.2 3 6 1 – LC7-K06105pppppppp 0.255

– 1 LC7-K06015pppppppp 0.255

2.2 4 4 9 1 – LC7-K09105pppppppp 0.255

– 1 LC7-K09015pppppppp 0.255

3 5.5 4 (> 440) 12 1 – LC7-K12105pppppppp 0.2555.5 (440)

– 1 LC7-K12015pppppppp 0.255

Volts a 24 42 48 110 115 220 230/50/60 Hz 240Code B7 D7 E7 F7 FE7 M7 U7

ContactorsContactors for motor control, 6 to 12 A in utilisation category AC-3 Control circuit: a.c.

References (continued)

LC7-K06105pp

Selection:pages 1/16 to 1/23

Characteristics:pages 2/18 to 2/21

Dimensions:page 2/40

Schemes:page 2/41

a

Page 8: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/25

2

2.2

- Contactor selection according to the utilisation category, see the Technical & Application guide available atwww.schneider.co.uk.- Mounting on 35 mm 7 rail or Ø 4 screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.

(1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Contactors LP1-K (0.8…1.15 Uc)

Coil with suppression device available: add 3 to the code required. Example: JD3.(2) When connecting an electronic sensor or timer in series with the coil of the contactor, select a 20 V coil (a controlcircuit voltage code Z7, c control circuit voltage code ZD) so as to compensate for the incurred voltage drop.

3-pole contactors

Standard power ratings Rated Instantaneous Basic reference. Weightof 3-phase motors operational auxiliary Complete with code50/60 Hz in category voltage contacts indicating controlAC-3 in AC-3 circuit voltage (1)

up to220 V 380 V 440/500 V 440 V240 V 415 V 660/690 VkW kW kW A N/O N/C kg

Screw clamp connections

1.5 2.2 3 6 1 – LP1-K0610pppppppp 0.225

– 1 LP1-K0601pppppppp 0.225

2.2 4 4 9 1 – LP1-K0910pppppppp 0.225

– 1 LP1-K0901pppppppp 0.225

3 5.5 4 (> 440 V) 12 1 – LP1-K1210pppppppp 0.2255.5 (440 V)

– 1 LP1-K1201pppppppp 0.225

Spring terminal connections

1.5 2.2 3 6 1 – LP1-K06103pppppppp 0.225

– 1 LP1-K06013pppppppp 0.225

2.2 4 4 9 1 – LP1-K09103pppppppp 0.225

– 1 LP1-K09013pppppppp 0.225

3 5.5 4 (> 440 V) 12 1 – LP1-K12103pppppppp 0.2255.5 (440 V)

– 1 LP1-K12013pppppppp 0.225

Faston connectors, 1 x 6.35 or 2 x 2.8

1.5 2.2 3 6 1 – LP1-K06107pppppppp 0.225

– 1 LP1-K06017pppppppp 0.225

2.2 4 4 9 1 – LP1-K09107pppppppp 0.225

– 1 LP1-K09017pppppppp 0.225

3 5.5 4 (> 440 V) 12 1 – LP1-K12107pppppppp 0.2255.5 (440 V)

– 1 LP1-K12017pppppppp 0.225

Solder pins for printed circuit boards

1.5 2.2 3 6 1 – LP1-K06105pppppppp 0.255

– 1 LP1-K06015pppppppp 0.255

2.2 4 4 9 1 – LP1-K09105pppppppp 0.255

– 1 LP1-K09015pppppppp 0.255

3 5.5 4 (> 440 V) 12 1 – LP1-K12105pppppppp 0.2555.5 (440 V)

– 1 LP1-K12015pp 0.255

Volts c 12 20 24(2) 36 48 60 72 100 110 125 155 174 200 220 230 240 250Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD

ContactorsContactors for motor control, 6 to 12 A in utilisation category AC-3Control circuit: d.c.

References

LP1-K0610pp

LP1-K06107pp

Selection:pages 1/16 to 1/23

Characteristics:pages 2/18 to 2/21

Dimensions:page 2/40

Schemes:page 2/41

c

Page 9: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/26

2.2

2

General purpose contactors

- Mounting on 35 mm " rail or by Ø 4 screws.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.Non inductive Type of Number Instantaneous Basic reference. Weightloads connection of auxiliary Complete with codeCategory poles contacts indicating controlAC-1 circuit voltage (1)Maximumcurrent atθ ≤ 50 °C

A N/O N/C kg

20 Screw clamp (2) 3 – 1 – LC1-K0910ii 0.225

3 – – 1 LC1-K0901ii 0.225

4 – – – LC1-K09004ii 0.180

2 2 – – LC1-K09008ii 0.180

Faston connectors 3 – 1 – LC1-K09107ii 0.2251 x 6.35or 2 x 2.8 3 – – 1 LC1-K09017ii 0.225

4 – – – LC1-K090047ii 0.180

2 2 – – LC1-K090087ii 0.180

Solder pins 3 – 1 – LC1-K09105ii 0.255for printedcircuit boards 3 – – 1 LC1-K09015ii 0.255

4 – – – LC1-K090045ii 0.210

2 2 – – LC1-K090085ii 0.210

Contactors for use in sensitive environments

Recommended for use in areas sensitive to noise, high interference mains supplies, etc.

- Coil with rectifier incorporated, suppressor fitted as standard.- Mounting on 35 mm " rail or Ø 4 screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.

20 Screw clamp (2) 3 – 1 – LC7-K0910ii 0.225

3 – – 1 LC7-K0901ii 0.225

4 – – – LC7-K09004ii 0.225

2 2 – – LC7-K09008ii 0.225

Faston connectors 3 – 1 – LC7-K09107ii 0.2251 x 6.35or 2 x 2.8 3 – – 1 LC7-K09017ii 0.225

4 – – – LC7-K090047ii 0.225

2 2 – – LC7-K090087ii 0.225

Solder pins 3 – 1 – LC7-K09105ii 0.255for printedcircuit boards 3 – – 1 LC7-K09015ii 0.255

4 – – – LC7-K090045ii 0.255

2 2 – – LC7-K090085ii 0.255(1) Standard control circuit voltages, see page opposite.(2) To order a spring terminal version, add 3 immediately before the coil code. Example: LC1-K09103ii.

Selection: Characteristics: Dimensions: Schemes:pages 1/14 and 1/15 pages 2/18 to 2/21 page 2/40 page 2/41

ContactorsK 3 and 4-pole contactors for control inutilisation category AC-1Control circuit: a.c.

References

LC1-K09004ii

LC7-K090047ii

a

Page 10: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/27

2

2.2

ContactorsK 3 and 4-pole contactors for control inutilisation category AC-1Control circuit: d.c.

References

3 and 4-pole contactors

- Mounting on 35 mm " rail or by Ø 4 screws.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.Non inductive Type of Number Instantaneous Basic reference. Weightloads connection of auxiliary Complete with codeCategory poles contacts indicating controlAC-1 circuit voltage (1)Maximumcurrent atθ ≤ 50 °CA N/O N/C kg

20 Screw clamp (2) 3 – 1 – LP1-K0910ii 0.225

3 – – 1 LP1-K0901ii 0.225

4 – – – LP1-K09004ii 0.225

2 2 – – LP1-K09008ii 0.225

Faston connectors 3 – 1 – LP1-K09107ii 0.2251 x 6.35or 2 x 2.8

3 – – 1 LP1-K09017ii 0.225

4 – – – LP1-K090047ii 0.225

2 2 – – LP1-K090087ii 0.225

Solder pins 3 – 1 – LP1-K09105ii 0.255for printedcircuit boards

3 – – 1 LP1-K09015ii 0.255

4 – – – LP1-K090045ii 0.255

2 2 – – LP1-K090085ii 0.255

(1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Contactors LC1-K (0.8…1.15 Uc) (0.85…1.1 Uc)Volts c 12 20 24 36 42 48 110 120 127 200/ 220/ 230 230/ 256 277 380/ 40050/60 Hz 208 230 240 400Code J7 Z7 B7 C7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7Volts c 400/ 440 500 575 600 660/50/60 Hz 415 690Code N7 R7 S7 SC7 X7 Y7Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72

Contactors LC7-K (0.85…1.1 Uc)Volts c 24 42 48 110 220 230/50/60 Hz 240Code B7 D7 E7 F7 M7 U7

Contactors LP1-K (0.8…1.15 Uc)Volts a 12 20 24 36 48 60 72 100 110 125 155 174 200 220 230 240 250Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UDCoil with integral suppression device available: add 3 to the code required. Example: JD3

(2) To order a spring terminal version, add 3 immediately before the coil code. Example: LP1-K09103ii.

LP1-K09004ii

Selection: Characteristics: Dimensions: Schemes:pages 1/14 and 1/15 pages 2/18 to 2/21 page 2/40 page 2/41

c

Page 11: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/28

2

2.2

- Reversing contactor selection according to utilisation category, see the Technical & Application guide available at www.schneider.co.uk.- Integral mechanical interlock.It is essential to link the contacts of the electrical interlock.- Pre-wired power circuit connections as standard on screw clamp versions.- Mounting on 35 mm 7 or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.

(1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Reversing contactors LC2-K (0.8…1.15 Uc) (0.85…1.1 Uc)

Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72(2) For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC(50…129 V) or LA4-KE1UG (130…250 V), see page 2/38.

3-pole general purpose reversing contactors

Standard power ratings Rated Instantan. Basic reference. Weightof 3-phase motors operational auxiliary Complete with code50/60 Hz in category current contacts indicating controlAC-3 in AC-3 circuit voltage (1) (2)

up to220 V 380 V 440/500 V 400 V240 V 415 V 660/690 VkW kW kW A N/O N/C kg

Screw clamp connections

1.5 2.2 3 6 1 – LC2-K0610pppppppp 0.390

– 1 LC2-K0601pppppppp 0.390

2.2 4 4 9 1 – LC2-K0910pppppppp 0.390

– 1 LC2-K0901pppppppp 0.390

3 5.5 4 (> 440) 12 1 – LC2-K1210pppppppp 0.3905.5 (440)

– 1 LC2-K1201pppppppp 0.390

Spring terminal connections

1.5 2.2 3 6 1 – LC2-K06103pppppppp 0.430

– 1 LC2-K06013pppppppp 0.430

2.2 4 4 9 1 – LC2-K09103pppppppp 0.430

– 1 LC2-K09013pppppppp 0.430

3 5.5 4 (> 440) 12 1 – LC2-K12103pppppppp 0.4305.5 (440)

– 1 LC2-K12013pppppppp 0.430

Volts a 12 20 24 36 42 48 110 115 120 127 200/ 220/ 230 230/ 256 277 380/ 40050/60 Hz 208 230 240 400Code J7 Z7 B7 C7 D7 E7 F7 FE7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7Volts a 400/ 440 480 500 575 600 660/50/60 Hz 415 690Code N7 R7 T7 S7 SC7 X7 Y7

Contactors Reversing contactors for motor control 6 to 12 A in utilisation category AC-3 Control circuit: a.c.

References

LC2-K0610pp

Selection:pages 1/16 to 1/23

Characteristics:pages 2/18 to 2/21

Dimensions:page 2/42

Schemes:page 2/43

a

Page 12: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/29

2

2.2

- Reversing contactor selection according to utilisation category, see the Technical & Application guide available at www.schneider.co.uk.- Integral mechanical interlock.It is essential to link the contacts of the electrical interlock.- Pre-wired power circuit connections as standard on screw clamp versions.- Mounting on 35 mm 7 or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.

(1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Reversing contactors LC2-K (0.8…1.15 Uc) (0.85…1.1 Uc)

Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72(2) For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC(50…129 V) or LA4-KE1UG (130…250 V), see page 2/38.

3-pole general purpose reversing contactors

Standard power ratings Rated Instantan. Basic reference. Weightof 3-phase motors operational auxiliary Complete with code50/60 Hz in category current contacts indicating controlAC-3 in AC-3 circuit voltage (1) (2)

up to220 V 380 V 440/500 V 400 V240 V 415 V 660/690 VkW kW kW A N/O N/C kg

Faston connectors, 1 x 6.35 or 2 x 2.8

1.5 2.2 3 6 1 – LC2-K06107pppppppp 0.370

– 1 LC2-K06017pppppppp 0.370

2.2 4 4 9 1 – LC2-K09107pppppppp 0.370

– 1 LC2-K09017pppppppp 0.370

3 5.5 4 (> 440) 12 1 – LC2-K12107pppppppp 0.3705.5 (440)

– 1 LC2-K12017pppppppp 0.370

Solder pins for printed circuit boards

1.5 2.2 3 6 1 – LC2-K06105pppppppp 0.430

– 1 LC2-K06015pppppppp 0.430

2.2 4 4 9 1 – LC2-K09105pppppppp 0.430

– 1 LC2-K09015pppppppp 0.430

3 5.5 4 (> 440) 12 1 – LC2-K12105pppppppp 0.4305.5 (440)

– 1 LC2-K12015pppppppp 0.430

Volts a 12 20 24 36 42 48 110 115 120 127 200/ 220/ 230 230/ 256 277 380/ 40050/60 Hz 208 230 240 400Code J7 Z7 B7 C7 D7 E7 F7 FE7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7Volts a 400/ 440 480 500 575 600 660/50/60 Hz 415 690Code N7 R7 T7 S7 SC7 X7 Y7

Contactors Reversing contactors for motor control 6 to 12 A in utilisation category AC-3 Control circuit: a.c.

References

Selection:pages 1/16 to 1/23

Characteristics:pages 2/18 to 2/21

Dimensions:page 2/42

Schemes:page 2/43

a

LC2-K06107pp

Page 13: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/30

2

2.2

Recommended for use in areas sensitive to noise, high interference mains supplies, etc.

- Reversing contactor selection according to utilisation category, see the Technical & Application guide available at www.schneider.co.uk.- Coil with rectifier incorporated, suppressor fitted as standard.- Integral mechanical interlock.It is essential to link the contacts of the electrical interlock.- Pre-wired power circuit connections as standard on screw clamp versions.- Mounting on 7 35 mm rail or Ø 4 mm screw fixing.- Screws in open, “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.

(1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Reversing contactors LC8-K (0.85…1.1 Uc)

(2) For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC(50…129 V) or LA4-KE1UG (130…250 V), see page 2/38.

3-pole reversing contactors for use in sensitive environments

Standard power ratings Rated Instantan. Basic reference. Weightof 3-phase motors operational auxiliary Complete with code50/60 Hz in category current contacts indicating controlAC-3 in AC-3 circuit voltage (1) (2)

up to220 V 380 V 440/500 V 400 V240 V 415 V 660/690 VkW kW kW A N/O N/C kg

Screw clamp connections

1.5 2.2 3 6 1 – LC8-K0610pppppppp 0.480

– 1 LC8-K0601pppppppp 0.480

2.2 4 4 9 1 – LC8-K0910pppppppp 0.480

– 1 LC8-K0901pppppppp 0.480

3 5.5 4 (> 440) 12 1 – LC8-K1210pppppppp 0.4805.5 (440

– 1 LC8-K1201pppppppp 0.480

Faston connectors 1 x 6.35 or 2 x 2.8

1.5 2.2 3 6 1 – LC8-K06107pppppppp 0.460

– 1 LC8-K06017pppppppp 0.460

2.2 4 4 9 1 – LC8-K09107pppppppp 0.460

– 1 LC8-K09017pppppppp 0.460

3 5.5 4 (> 440) 12 1 – LC8-K12107pppppppp 0.4605.5 (440)

– 1 LC8-K12017pppppppp 0.460

Solder pins for printed circuit boards

1.5 2.2 3 6 1 – LC8-K06105pppppppp 0.520

– 1 LC8-K06015pppppppp 0.520

2.2 4 4 9 1 – LC8-K09105pppppppp 0.520

– 1 LC8-K09015pppppppp 0.520

3 5.5 4 (> 440) 12 1 – LC8-K12105pppppppp 0.5205.5 (440)

– 1 LC8-K12015pppppppp 0.520

Volts a 24 42 48 110 115 220 230/50/60 Hz 240Code B7 D7 E7 F7 FE7 M7 U7

Contactors Reversing contactors for motor control 6 to 12 A in utilisation category AC-3 Control circuit: a.c.

References (continued)

LC8-K06105pp

Selection:pages 1/16 to 1/23

Characteristics:pages 2/18 to 2/21

Dimensions:page 2/42

Schemes:page 2/43

a

Page 14: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/31

2

2.2

- Contactor selection according to utilisation category, see the Technical & Application guide available at www.schneider.co.uk.- Integral mechanical interlock.It is essential to link the contacts of the electrical interlock.- Pre-wired power circuit connections as standard on screw clamp versions.- Mounting on 35 mm 7 or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.

Spring terminal connections

Faston connectors, 1 x 6.35 or 2 x 2.8

Solder pins for printed circuit boards

(1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Reversing contactors LP2-K (0.8…1.15 Uc)

Coil with integral suppression device available: add 3 to the code required. Example: JD3.(2) When connecting an electronic sensor or timer in series with the coil of the contactor, select a 20 V coil (a controlcircuit voltage code Z7, c control circuit voltage code ZD) so as to compensate for the incurred voltage drop.

3-pole reversing contactors

Standard power ratings Rated Instantan. Basic reference. Weightof 3-phase motors operational auxiliary Complete with code50/60 Hz in category current contacts indicating controlAC-3 in AC-3 circuit voltage (1) (2)

up to220 V 380 V 440/500 V 400 V240 V 415 V 660/690 VkW kW kW A N/O N/C kg

Screw clamp connections

1.5 2.2 3 6 1 – LP2-K0610pppppppp 0.480– 1 LP2-K0601pppppppp 0.480

2.2 4 4 9 1 – LP2-K0910pppppppp 0.480– 1 LP2-K0901pppppppp 0.480

3 5.5 4 (> 440) 12 1 – LP2-K1210pppppppp 0.4805.5 (440) – 1 LP2-K1201pppppppp 0.480

1.5 2.2 3 6 1 – LP2-K06103pppppppp 0.520– 1 LP2-K06013pppppppp 0.520

2.2 4 4 9 1 – LP2-K09105pppppppp 0.520– 1 LP2-K09015pppppppp 0.520

3 5.5 4 (> 440) 12 1 – LP2-K12105pppppppp 0.5205.5 (440) – 1 LP2-K12015pppppppp 0.520

1.5 2.2 3 6 1 – LP2-K06107pppppppp 0.460– 1 LP2-K06017pppppppp 0.460

2.2 4 4 9 1 – LP2-K09107pppppppp 0.460– 1 LP2-K09017pppppppp 0.460

3 5.5 4 (> 440) 12 1 – LP2-K12107pppppppp 0.4605.5 (440) – 1 LP2-K12017pppppppp 0.460

1.5 2.2 3 6 1 – LP2-K06105pppppppp 0.520– 1 LP2-K06015pppppppp 0.520

2.2 4 4 9 1 – LP2-K09105pppppppp 0.520– 1 LP2-K09015pppppppp 0.520

3 5.5 4 (> 440) 12 1 – LP2-K12105pppppppp 0.5205.5 (440) – 1 LP2-K12015pppppppp 0.520

Volts c 12 20 24 36 48 60 72 100 110 125 155 174 200 220 230 240 250Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD

Contactors Reversing contactors for motor control6 to 12 A in utilisation category AC-3Control circuit: d.c.

References

LP2-K0610pp

LP2-K06107pp

Selection:pages 1/16 to 1/23

Characteristics:pages 2/18 to 2/21

Dimensions:page 2/42

Schemes:page 2/43

c

Page 15: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/32

2

2.2

- Warning: reversing contactors LC2-K0910pp and LC2-K0901pp are pre-wired for reverse motor operation asstandard.- Reversing contactor selection according to utilisation category, see the Technical & Application guide available atwww.schneider.co.uk.- Integral mechanical interlock.It is essential to link the contacts of the electrical interlock.- Mounting on 35 mm 7 or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.

(1) Choice between 9 and 12 A depends on number of operating cycles, see AC-1 curve in the Technical & Applicationguide available at www.schneider.co.uk.(2) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Reversing contactors LC2-K (0.8…1.15 Uc) (0.85…1.1 Uc)

Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72(3) For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC(50…129 V) or LA4-KE1UG (130…250 V), see page 2/38.

3 or 4-pole general purpose reversing contactors (1)

Non inductive Number Instantan. Basic reference. Weightloads of auxiliary Complete with codecategory poles contacts indicating controlAC-1 circuit voltageMaximum (2) current atθ ≤ 50 ˚CA N/O N/C kg

Screw clamp connections

20 3 – 1 – LC2-K0910pppppppp 0.390

or LC2-K1210pppppppp 0.390

3 – – 1 LC2-K0901pppppppp 0.390

or LC2-K1201pppppppp 0.390

4 – – – LC2-K09004pppppppp 0.380

or LC2-K12004pppppppp 0.380

Spring terminal connections

20 3 – 1 – LC2-K09103pppppppp 0.390

or LC2-K12103pppppppp 0.390

3 – – 1 LC2-K09013pppppppp 0.390

or LC2-K12013pppppppp 0.390

4 – – – LC2-K090043pppppppp 0.380

or LC2-K120043pppppppp 0.380

Volts a 12 20 24(3) 36 42 48 110 115 120 127 200/ 220/ 230 230/ 256 277 380/ 40050/60 Hz 208 230 240 400Code J7 Z7 B7 C7 D7 E7 F7 FE7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7Volts a 400/ 440 480 500 575 600 660/50/60 Hz 415 690Code N7 R7 T7 S7 SC7 X7 Y7

ContactorsReversing contactors for control in utilisation category AC-1, 20 AControl circuit: a.c.

References

Selection:pages 1/14 and 1/15

Characteristics:pages 2/18 to 2/21

Dimensions:page 2/42

Schemes:page 2/43

a

LC2-K0910pppppppp

Page 16: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/33

2

2.2

- Warning: reversing contactors LC2-K0910pp and LC2-K0901pp are pre-wired for reverse motor operation asstandard.- Reversing contactor selection according to utilisation category, see the Technical & Application guide available atwww.schneider.co.uk.- Integral mechanical interlock.It is essential to link the contacts of the electrical interlock.- Mounting on 35 mm 7 or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.

(1) Choice between 9 and 12 A depends on number of operating cycles, see AC-1 curve in the Technical & Applicationguide available at www.schneider.co.uk.(2) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Reversing contactors LC2-K (0.8…1.15 Uc) (0.85…1.1 Uc)

Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72(3) For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC(50…129 V) or LA4-KE1UG (130…250 V), see page 2/38.

3 or 4-pole general purpose reversing contactors (1)

Non inductive Number Instantan. Basic reference. Weightloads of auxiliary Complete with codecategory poles contacts indicating controlAC-1 circuit voltageMaximum (2)current atθ ≤ 50 ˚CA N/O N/C kg

Faston connectors, 1 x 6.35 or 2 x 2.8

20 3 – 1 – LC2-K09107pppppppp 0.370

or LC2-K12107pppppppp 0.370

3 – – 1 LC2-K09017pppppppp 0.370

or LC2-K12017pppppppp 0.370

4 – – – LC2-K090047pppppppp 0.370

or LC2-K120047pppppppp 0.370

Solder pins for printed circuit boards

20 3 – 1 – LC2-K09105pppppppp 0.430

or LC2-K12105pppppppp 0.430

3 – – 1 LC2-K09015pppppppp 0.430

or LC2-K12015pppppppp 0.430

4 – – – LC2-K090045pppppppp 0.430

or LC2-K120045pppppppp 0.430

Volts a 12 20 24(3) 36 42 48 110 115 120 127 200/ 220/ 230 230/ 256 277 380/ 40050/60 Hz 208 230 240 400Code J7 Z7 B7 C7 D7 E7 F7 FE7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7Volts a 400/ 440 480 500 575 600 660/50/60 Hz 415 690Code N7 R7 T7 S7 SC7 X7 Y7

Contactors Reversing contactors for control in utilisation category AC-1, 20 AControl circuit: a.c.

References

Selection:pages 1/14 and 1/15

Characteristics:pages 2/18 to 2/21

Dimensions:page 2/42

Schemes:page 2/43

LC2-K090045pp

a

Page 17: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/34

2

2.2

Recommended for use in areas sensitive to noise, high interference mains supplies, etc.

- Warning: reversing contactors LC2-K0910pp and LC2-K0901pp are pre-wired for reverse motor operation asstandard.- Reversing contactor selection according to utilisation category, see the Technical & Application guide available atwww.schneider.co.uk.- Integral mechanical interlock.It is essential to link the contacts of the electrical interlock.- Mounting on 35 mm 7 or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.

(1) Choice between 9 and 12 A depends on number of operating cycles, see AC-1 curve in the Technical & Applicationguide available at www.schneider.co.uk.(2) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Reversing contactors LC8-K (0.85…1.1 Uc): coil with integral rectifier and suppression device as standard.

(3) For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC(50…129 V) or LA4-KE1UG (130…250 V), see page 2/38.

3 or 4-pole reversing contactors for use in sensitive environments (1)

Non inductive Number Instantan. Basic reference. Weightloads of auxiliary Complete with codecategory poles contacts indicating controlAC-1 circuit voltageMaximum (2) (3)current atθ ≤ 50 ˚CA N/O N/C kg

Screw clamp connections

20 3 – 1 – LC8-K0910pppppppp 0.480

or LC8-K1210pppppppp 0.480

3 – – 1 LC8-K0901pppppppp 0.480

or LC8-K1201pppppppp 0.480

4 – – – LC8-K09004pppppppp 0.470

or LC8-K12004pppppppp 0.470

Faston connectors, 1 x 6.35 or 2 x 2.8

20 3 – 1 – LC8-K09107pppppppp 0.460

or LC8-K12107pppppppp 0.460

3 – – 1 LC8-K09017pppppppp 0.460

or LC8-K12017pppppppp 0.460

4 – – – LC8-K090047pppppppp 0.460

or LC8-K120047pppppppp 0.460

Solder pins for printed circuit boards

20 3 – 1 – LC8-K09105pppppppp 0.520

or LC8-K12105pppppppp 0.520

3 – – 1 LC8-K09015pppppppp 0.520

or LC8-K12015pppppppp 0.520

4 – – – LC8-K090045pppppppp 0.520

or LC8-K120045pppppppp 0.520

Volts a 24 42 48 110 115 220 230/50/60 Hz 240Code B7 D7 E7 F7 FE7 M7 U7

ContactorsReversing contactors for control in utilisation category AC-1, 20 AControl circuit: a.c.

References (continued)

Selection:pages 1/14 and 1/15

Characteristics:pages 2/18 to 2/21

Dimensions:page 2/42

Schemes:page 2/43

LC8-K09105pp

a

Page 18: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/35

2

2.2

- Warning: reversing contactors LC2-K0910pp and LC2-K0901pp are pre-wired for reverse motor operation asstandard.- Reversing contactor selection according to utilisation category, see the Technical & Application guide available atwww.schneider.co.uk.- Integral mechanical interlock.It is essential to link the contacts of the electrical interlock.- Mounting on 35 mm 7 or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/36 to 2/39.

(1) Choice between 9 and 12 A depends on number of operating cycles, see AC-1 curve in the Technical & Applicationguide available at www.schneider.co.uk.(2) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Reversing contactors LP2-K (0.8…1.15 Uc)

Coil with suppression device available: add 3 to the code required. Example: JD3(3) When connecting an electronic sensor or timer in series with the coil of the contactor, select a 20 V coil (a controlcircuit voltage code Z7, c control circuit voltage code ZD) in order to compensate for the incurred voltage drop

3 or 4-pole reversing contactors (1)

Non inductive Number Instantan. Basic reference. Weightloads of auxiliary Complete with codecategory poles contacts indicating controlAC-1 circuit voltageMaximum (2) (3)current atθ ≤ 50 ˚CA N/O N/C kg

Screw clamp connections

20 3 – 1 – LP2-K0910pppppppp 0.480or LP2-K1210pppppppp 0.480

3 – – 1 LP2-K0901pppppppp 0.480or LP2-K1201pppppppp 0.480

4 – – – LP2-K09004pppppppp 0.480or LP2-K12004pppppppp 0.480

Spring terminal connections

20 3 – 1 – LP2-K09103pppppppp 0.480or LP2-K12103pppppppp 0.480

3 – – 1 LP2-K09013pppppppp 0.480or LP2-K12013pppppppp 0.480

4 – – – LP2-K090043pppppppp 0.480or LP2-K120043pppppppp 0.480

Faston connectors, 1 x 6.35 or 2 x 2.8

20 3 – 1 – LP2-K09107pppppppp 0.460or LP2-K12107pppppppp 0.460

3 – – 1 LP2-K09017pppppppp 0.460or LP2-K12017pppppppp 0.460

4 – – – LP2-K090047pppppppp 0.460or LP2-K120047pppppppp 0.460

Solder pins for printed circuit boards

20 3 – 1 – LP2-K09105pppppppp 0.520or LP2-K12105pppppppp 0.520

3 – – 1 LP2-K09015pppppppp 0.520or LP2-K12015pppppppp 0.520

4 – – – LP2-K090045pppppppp 0.520or LP2-K120045pppppppp 0.520

Volts c 12 20 24(3) 36 48 60 72 100 110 125 155 174 200 220 230 240 250Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD

ContactorsReversing contactors for control inutilisation category AC-1, 20 AControl circuit: d.c.

References

Selection:pages 1/14 and 1/15

Characteristics:pages 2/18 to 2/21

Dimensions:page 2/42

Schemes:page 2/43

LP2-K090045pp

c

Page 19: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/36

2

2.2

LC1, LC7, LP1-K

LC1, LC7, LP1-K

LC1, LC7, LP1-K

LC1, LP1-K

Page 20: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/37

2

2.2

Recommended for standard applications. Clip-on front mounting, 1 block per contactor

- Relay output, with common point changeover contact,a or c 240 V, 2 A maximum.- Control voltage: 0.85…1.1 Uc.- Maximum switching capacity: 250 VA or 150 W.- Operating temperature: -10…+ 60 ˚C.- Reset time: 1.5 s during the time delay period, 0.5 s after the time delay period.

Clip-on front mounting, 1 block per contactor

Instantaneous auxiliary contact blocks

Type of connection For use with Composition Reference Weightcontactors

N/O N/C kg

Screw clamp LC1, LC2 2 – LA1-KN20 0.045LC7, LC8 – 2 LA1-KN02 0.045LP1, LP2 1 1 LA1-KN11 0.0453 or 4-pole 4 – LA1-KN40 0.045

3 1 LA1-KN31 0.0452 2 LA1-KN22 0.0451 3 LA1-KN13 0.045– 4 LA1-KN04 0.045

Spring terminal LC1, LC2, 2 – LA1-KN203 0,045LP1, LP2 – 2 LA1-KN023 0,0453 or 4-pole 1 1 LA1-KN113 0.045

4 – LA1-KN403 0.0453 1 LA1-KN313 0.0452 2 LA1-KN223 0.0451 3 LA1-KN133 0.045– 4 LA1-KN043 0.045

Faston LC1, LC2 2 – LA1-KN207 0.0451 x 6.35 LC7, LC8 – 2 LA1-KN027 0.045or 2 x 2.8 LP1, LP2 1 1 LA1-KN117 0.045

3 or 4-pole 4 – LA1-KN407 0.0453 1 LA1-KN317 0.0452 2 LA1-KN227 0.0451 3 LA1-KN137 0.045– 4 LA1-KN047 0.045

With terminal referencing conforming to standard EN 50012. Clip-on front mounting, 1 block per contactor

Screw clamp LC1, LC2 – 2 LA1-KN02M 0.045with terminal LC7, LC8 1 1 LA1-KN11M 0.045referencing LP1, LP2 3 1 LA1-KN31M 0.045conforming to 3-pole + N/O 2 2 LA1-KN22M 0.045standard EN 50012 1 3 LA1-KN13M 0.045

LC1, LC2 1 1 LA1-KN11P 0.045LC7, LC8LP1, LP24-pole 2 2 LA1-KN22P 0.045

Electronic time delay auxiliary contact blocks

Voltage Type Timing Composition Reference Weightrange

V s C/O kg

a or c 24…48 On-delay 1…30 1 LA2-KT2E 0.040

a 110…240 On-delay 1…30 1 LA2-KT2U 0.040

Contactors Contactors and reversing contactors, types LCp-K and LPp-KInstantaneous and time delay auxiliary contacts

References

Characteristics:pages 2/18 to 2/21

Dimensions:pages 2/40 and 2/42

Schemes:pages 2/41 and 2/43

Page 21: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/38

2

2.2

(1) Protection by limitation of the transient voltage up to 2 Uc maximum.Maximum reduction of transient voltage peaks.Slight time delay on drop-out (1.1 to 1.5 times the normal time).(2) No overvoltage or oscillation frequency.Polarised component.Slight time delay on drop-out (1.1 to 1.5 times the normal time).(3) Protection by limitation of the transient voltage up to 3 Uc maximum and limitation of the oscillation frequency.Slight time delay on drop-out (1.2 to 2 times the normal time).

Mounting Type For voltages: Sold in Unit Weightand connection lots of reference kg

Clip-on fixing Varistor a and c 5 LA4-KE1B 0.010on the front of (1) 12…24 Vcontactors LC1 and LP1, with locatingdevice.No tools required.

a and c 5 LA4-KE1E 0.01032…48 V

a and c 5 LA4-KE1FC 0.01050…129 V

a and c 5 LA4-KE1UG 0.010201…250 V

Diode + c 5 LA4-KC1B 0.010Zener diode (2) 12…24 V

c 5 LA4-KC1E 0.01032…48 V

RC (3) a 5 LA4-KA1U 0.010220…250 V

Contactors Contactors and reversing contactors, types LCp-K and LPp-KSuppressor modules incorporating LED indicator

References

LA4-Kppp

Characteristics:pages 2/18 to 2/21

Dimensions:pages 2/40 and 2/42

Schemes:pages 2/41 and 2/43

Page 22: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/39

2

2.2

(1) Order 1 mounting plate for fixing a contactor and 2 mounting plates for fixing a reversing contactor.(2) Complete the reference by replacing the p with the required character.

Mounting and marking accessories

Description Application Sold in Unit Weightlots of reference kg

Mounting For fixing Clip-on 1 LA9-D973 0.025plates (1) on 1 4 rail

For fixing 110/120 mm 1 DX1-AP25 0.065on 2 4 rails fixing centres

Marker Clip-on Onto front of 100 LA9-D90 0.001holder contactor

Clip-in 4 maximum Strips of 25 AB1-Rpppp (2) 0.002markers per contactor 10 identical

numbers 0…9

Strips of 25 AB1-Gpppp (2) 0.00210 identicalcapitalletters A…Z

Cabling accessories

Description Application Sold in Unit Weightlots of reference kg

Paralleling For 2 poles With screw 4 LA9-E01 0.010links clamp terminals

For 4 poles With screw 2 LA9-E02 0.015clamp terminals

Set of 6 power For 3-pole For contactors 100 LA9-K0969 0.010connections reversing with screw

contactors for clamp terminalsmotor control

Set of 4 power For 4-pole For contactors 100 LA9-K0970 0.010connections changeover with screw

contactor clamp terminalspairs

Contactors Contactors and reversing contactors, types LCp-K and LPp-KAccessories

References

LA9-E01

DX1-AP25

Characteristics:pages 2/18 to 2/21

Dimensions:pages 2/40 and 2/42

Schemes:pages 2/41 and 2/43

Page 23: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/40

2

2.2

57

58

45

45

35= =

505

557 21

110

45

120

57 27

DZ5-ME5

6

25

22

5722

58

57

LA2-KT

58

38

38 38

27

50 53

45

58

8,65 = = = A1

A21,9

5735

LA1-K

58 50=

=

35

45

= =

Electronic time delay auxiliary contact blocksLA2-KT

Suppressor modules

ContactorsLC1-K, LC7-K, LP1-KOn panel On mounting rail AM1-DP200 or AM1 DE200 (7 35 mm)

On one asymmetrical rail DZ5-MB with clip-on mounting plateLA9-D973 DX1-AP25

On printed circuit board

On contactor

LA4-Kp On contactor

ContactorsContactors, types LCp-K and LP1-K

Dimensions,mounting

Selection:pages 1/14 to 1/37

Characteristics:pages 2/18 to 2/21

References:pages 2/22 to 2/35

Schemes:page 2/41

Page 24: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/41

2

2.2

+ –

A1

A2

1815

16

A1

A2

A1

A2

13/N

O14

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6 2221

/NC

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

7/L4

T4/

8

R1

R2

A1

A2

12

34

R3

R4

53/N

O54

63/N

O64

61/N

C62

51/N

C52

61/N

C62

53/N

O54

54 64 74

53/N

O

63/N

O

73/N

O

83/N

O84

53/N

O54

61/N

C62

73/N

O74

83/N

O84

53/N

O54

61/N

C62

71/N

C72

83/N

O84 54 62 72 82

53/N

O

61/N

C

71/N

C

81/N

C

51/N

C52

61/N

C62

71/N

C72

81/N

C82

31/N

C32

21/N

C22 22 34

21/N

C

33/N

O

33/N

O32

21/N

C22

43/N

O42

53/N

O54

21/N

C22

43/N

O44

53/N

O54

31/N

C32

21/N

C22

53/N

O54

31/N

C32

41/N

C42

21/N

C22

13/N

O14 22

13/N

O14

21/N

C

31/N

C32

43/N

O44

Instantaneous auxiliary contacts LA1-K

Terminal referencing conforming to standard EN 50012For 3-pole contactors

For 4-pole contactors

For contactors LCp-K and LPp-K1 C/O

3-pole contactors Integral suppression deviceLC1-K, LC7-K, LP1-K LC7-K3 P + N/O 3 P + N/C

4-pole contactors, 9 A Integral coil suppression deviceLC1-K, LC7-K, LP1-K LC7-K4 P 2 P N/O + 2 P N/C

For contactors LCp-K and LPp-K2 N/O 2 N/C 1 N/O + 1 N/CLA1-KN20 LA1-KN02 LA1-KN11LA1-KN207 LA1-KN027 LA1-KN117

4 N/O 3 N/O + 1 N/C 2 N/O + 2 N/C 1 N/O + 3 N/C 4 N/CLA1-KN40 LA1-KN31 LA1-KN22 LA1-KN13 LA1-KN04LA1-KN407 LA1-KN317 LA1-KN227 LA1-KN137 LA1-KN047

2 N/C 1 N/O + 1 N/C 3 N/O + 1 N/C 2 N/O + 2 N/C 1 N/O + 3 N/CLA1-KN02M LA1-KN11M LA1-KN31M LA1-KN22M LA1-KN13M

1 N/O + 1 N/C 2 N/O + 2 N/CLA1-KN11P LA1-KN22P

Electronic time delay auxiliary contact blocks Suppressor modulesLA2-KT LA4-KC LA4-KE

ContactorsContactors, types LCp-K and LPp-K

Schemes

Selection:pages 1/12 to 1/35

Characteristics:pages 2/18 to 2/21

References:pages 2/22 to 2/35

Schemes:page 2/41

Page 25: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/42

2

2.2

57

58

90

90

35= =

505

557 21

57 27

DZ5-ME5

90

110

120

6

25

22

5722

58

5735

LA1-K

58 50=

=

90

80 ==

45

58

8,65 = = =

A1

A2 50

45

8,65===

53

A1

A2

38 38

27

57

LA2-KT

58

38

LC2-K, LC8-K, LP2-K

On one asymmetrical rail DZ5-MB with 2 clip-on mounting plates LA9-D973 or on 2 mounting plates DX1-AP25.

On printed circuit board for reversing contactors or 2 contactors mounted side by side

Electronic time delay contact blocksLA2-KT

Suppressor modules

Reversing contactors

On panel On mounting rail AM1-DP200 or AM1-DE200 ( 7 35 mm)

2 x LA9-D973 2 x DX1-AP25

On reversing contactors

LA4-Kp On reversing contactors

Selection:pages 1/14 to 1/37

Characteristics:pages 2/18 to 2/21

References:pages 2/22 to 2/35

Schemes:page 2/43

ContactorsReversing contactors, types LCp-K and LP2-K

Dimensions,mounting

Page 26: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/43

2

2.2

+ –

61/N

C62

53/N

O54

13/N

O14

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

13/N

O14

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

21/N

C22

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

21/N

C22

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

A1

A2

13/N

O14

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

13/N

O14

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

21/N

C22

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

21/N

C22

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

A1

A2

12

34

56

A1

A2

12

34

56

1/L1

1/L2

1/L3

2/L1

2/L2

2/L3

L1 L2 L3

78

1N

78

2NN

A1

A2

12

34

56

A1

A2

12

34

78

78

56

A1

A2

53/N

O54

63/N

O64

61/N

C62

51/N

C52

54 64 74

53/N

O

63/N

O

73/N

O

83/N

O84 62 74

53/N

O54

61/N

C

73/N

O

83/N

O84

53/N

O54

61/N

C62

71/N

C72

83/N

O84 54 62 72 82

53/N

O

61/N

C

71/N

C

81/N

C

51/N

C52

61/N

C62

71/N

C72

81/N

C82

A1

A2

1815

16

With screw clamp terminals

With Faston connectors or solder pins (printed circuit board)

Instantaneous auxiliary contact blocks LA1-KFor contactors LCp-K and LP2-K

For contactors LCp-K, LP2-K

Auxiliary contacts with terminal referencing conforming to standard EN 50012 see page 2/41

For contactors LCp-K and LPp-K1 C/O

3-pole reversing contactors Integral suppression deviceLC2-K, LC8-K, LP2-K LC8-K

3 P + N/O 3 P + N/C

3 P+ N/O 3 P + N/C

4-pole reversing contactors Integral suppression deviceLC2-K, LC8-K, LP2-K LC8-KWith screw clamp terminals With Faston connectors or

solder pins (printed circuit board)4 P 4 P

2 N/O 2 N/C 1 N/O + 1 N/C Terminal referencing conforming to standard EN 50012LA1-KN20 LA1-KN02 LA1-KN11 1 N/O + 1 N/CLA1-KN207 LA1-KN027 LA1-KN117 LA1-KN11P

4 N/O 3 N/O + 1 N/C 2 N/O + 2 N/C 1 N/O + 3 N/C 4 N/CLA1-KN40 LA1-KN31 LA1-KN22 LA1-KN13 LA1-KN04LA1-KN407 LA1-KN317 LA1-KN227 LA1-KN137 LA1-KN047

Electronic time delay contact blocks Suppressor modulesLA2-KT LA4-KC LA4-KE

Schemes

Selection:pages 1/14 to 1/37

Characteristics:pages 2/18 to 2/21

References:pages 2/22 to 2/35

Dimensions:page 2/42

Contactors3 and 4-pole reversing contactors, types LCp-K and LPp-K

Page 27: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/44

2

2.2

Protection relaysK thermal overload relays, adjustable from 0.11 to 16 A

(1) Please call our Customer information centre on 0870 608 8 608.(2) Very low safety voltage.

Environment

Conforming to standards IEC/EN 60947-4-1, NF C 63-650, VDE 0660

Approvals Pending UL, CSA

Protective treatment Conforming to IEC 68 (DIN 50016) “TC” (Klimafest, Climateproof)

Degree of protection Conforming to VDE 0106 Protection against direct finger contact

Ambient air temperature Storage ˚C - 40...+ 70around the device

For normal operation (IEC 947) ˚C - 20...+ 55 (without derating)

Operating limit ˚C - 30...+ 60 (with derating) (1)

Maximum operating altitude Without derating m 2000

Operating positions Vertical axis Horizontal axis

Without derating With derating (1)

Flame resistance Conforming to UL 94 Self-extinguishing material V1Conforming to NF F 16-101 and 16-102 Conforming to requirement 2

Shock resistance, hot state Conforming to IEC 68, N/C contact 10 gn(1/2 sine wave, 11 ms) Conforming to IEC 68, N/O contact 10 gn

Vibration resistance, hot state Conforming to IEC 68, N/C contact 2 gn5 to 300 Hz Conforming to IEC 68, N/O contact 2 gn

Safe separation of circuits Conforming to VDE 0106 and IEC 536 VLSV (2), up to 400 V

Cabling Minimum Maximum Maximum to IEC 947Screw clamp terminals Solid cable mm2 1 x 1.5 2 x 4 1 x 4 + 1 x 2.5

Flexible cable without cable end mm2 1 x 0.75 2 x 4 2 x 2.5Flexible cable with cable end mm2 1 x 0.34 1 x 1.5 + 1 x 2.5 1 x 1.5 + 1 x 2.5

Tightening torque Philips head n˚ 2 - Ø 6 N.m 0.8

Mounting Directly under the contactor or reversing contactor

Connections Made automatically when mounted under the contactor, as follows:- contactor terminal A2 connected to overload relay terminal 96 on all products,- contactor terminal 14 connected to overload relay terminal 95 on products with 3 P + N/O. When using 3 P + N/C, or 4 P contactors, or the N/O auxiliary contact marked 13-14, at a voltage other than the coil voltage, break off the link marked 14.

Auxiliary contact characteristics

Number of contacts 1 N/C + 1 N/O

Conventional thermal current A 6

Short-circuit protection Conforming to IEC 947, VDE 0660. gG fuse A 6 max.or circuit-breaker GB2-CBpp

Maximum power a.c. V 24 48 110 220/230 400 415/440 600/690of the controlled contactor coils (sealed) VA 100 200 400 600 600 600 600(Occasional operatingcycles of contact 95-96) d.c. V 24 48 110 220 250 – –

W 100 100 50 45 35 – –

Maximum operational voltage a.c., category AC-15 V 690

d.c., category DC-13 V 250

Characteristics

References:page 2/46

Dimensions:page 2/47

Schemes:page 2/47

Page 28: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/45

2

2.2

2 h1h 20 min

1 h

40 min

20 min

10 min

6 min

4 min

2 min

1 min40 s

20 s

10 s

6 s4 s

2 s

1s1 1,2 1,5 2 3 4 5 6 8 10 15

12

2 h 1h 20 min

1 h

40 min

20 min

10 min

6 min

4 min

2 min

1 min40 s

20 s

10 s

6 s4 s

2 s

1 s1 1,2 1,5 2 3 4 5 6 8 10 15

Electrical characteristics of the power circuit

Rated operational voltage (Ue) Up to V 690

Rated insulation voltage (Ui) Conforming to IEC/EN 60947-4-1 V 690Conforming to VDE 0110 group C V 750Conforming to CSA C 22-2 n˚ 14 V 600

Rated impulse withstand kV 6voltage (Uimp)

Frequency limits Hz Up to 400of the operational current

Power dissipated per pole W 2

Operating characteristics

Sensitivity to phase failure Conforming to IEC 947 Yes

Reset Manual or automatic Selected by means of a lockable and sealable switchon the front of the relay

Signalling On front of relay Trip indicator

Reset-Stop function Pressing the Reset-Stop button:- actuates the N/C contact- has no effect on the N/O contact

Test function By pushbutton Pressing the Test button enables:- checking of the control circuit wiring- simulation of overload tripping (actuation of both N/Cand N/O contacts, and of the trip indicator)

Short-circuit protection See page 2/46

Tripping curves

Average operating time

Balanced 3-phase operation, Balanced operation with 2 phases only, from cold state from cold state

1 Setting: at lower end of scale2 Setting: at upper end of scale

Protection relaysK thermal overload relays, adjustable from 0.11 to 16 A

Characteristics

References:page 2/46

Dimensions:page 2/47

Schemes:page 2/47

x setting current (Ir)x setting current (Ir)

Class 10 A Class 10 A

related to multiples ofthe current settingClass 10 A

Time Time

Page 29: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/46

2

2.2

These overload relays are designed for the protection of motors. They are compensated and phase failure sensitive.Resetting can either be manual or automatic.Direct mounting: under the contactor for versions with screw clamp terminals only; pre-wired terminals, see pages 2/44and 2/47.Separate mounting: using terminal block LA7-K0064 (see below).On the front face of the overload relay:- selection of reset mode: Manual (marked H) or Automatic (marked A),- red pushbutton: Trip Test function,- blue pushbutton: Stop and manual Reset,- yellow trip flag indicator: overload relay tripped.Protection by fuses or by magnetic circuit-breaker type GV2-LE, see page 3/41.

relay on 35 mm 7 rail

3-pole relays with screw clamp terminals

Relay Fuses to be used with selected relay Reference Weightsetting Maximum ratingrange Type

aM gG BS88A A A A kg

Class 10 A (the standard specifies a tripping time of between 2 and 10 seconds at 7.2 In)

0.11…0.16 0.25 2 2 LR2-K0301 0.145

0.16…0.23 0.25 2 2 LR2-K0302 0.145

0.23…0.36 0.5 2 2 LR2-K0303 0.145

0.36…0.54 1 4 4 LR2-K0304 0.145

0.54…0.8 1 4 4 LR2-K0305 0.145

0.8…1.2 2 6 6 LR2-K0306 0.145

1.2…1.8 2 6 6 LR2-K0307 0.145

1.8…2.6 4 10 10 LR2-K0308 0.145

2.6…3.7 4 16 16 LR2-K0310 0.145

3.7…5.5 6 16 16 LR2-K0312 0.145

5.5…8 8 20 20 LR2-K0314 0.145

8…11.5 10 25 20 LR2-K0316 0.145

10…14 16 32 25 LR2-K0321 0.145

12…16 20 40 32 LR2-K0322 0.145

Overload relays for unbalanced loads

Class 10 A: To order, replace the prefix LR2 by LR7 in the references selected from above (only applicable to overload relays LR2-K0305 to LR2-K0322). Example: LR7-K0308.

Accessory

Description Type of connection Reference Weightkg

Terminal block for separate Screw clamp LA7-K0064 0.100clip-on mounting of the overload

Protection relaysK thermal overload relays, adjustable from 0.11 to 16 A

References

LR2-K0301

LA7-K0064

Characteristics:pages 2/44 and 2/45

Dimensions:page 2/47

Schemes:page 2/47

Page 30: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/47

2

2.2

65

8=

=35= =

45

58

50

116

38

80

75

c

45

1 3 5

2 4 6

9798

9596

AH

1 3 5 13 A1

2 4 6 14 A2

2 4 6

97 95 98 96 – KM1

A2

A1

9695

1314

– KM1

O

95

96

LR2-KDirect mounting beneath the contactor Separate mounting with terminal block LA7-K0064

on 35 mm 7 rail(AM1-DP200 or AM1-DE200)

AM1- cDP200 78.5DE200 86

LR2-K LR2-K + LCpppp-KPre-wiring scheme

Note: If pre-wiring is not required, break off the 2 links located on the thermal overload relay.

Protection relaysK thermal overload relays, adjustable from 0.11 to 16 A

Dimensions,mounting, schemes

Characteristics:pages 2/44 and 2/45

References:page 2/46

Reset/stop

Test

Page 31: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/48

2

2.2 1

80

Environment

Conforming to standards IEC/EN 60947-4-1, NF C 63-110, VDE 0660

Approvals LPpppp-K06, LPpppp-K09, LPpppp-K12 UL, CSA

Operating positions Vertical axis Horizontal axis

Without derating Without derating Contactor energising voltage at 0.85 UcMax to

Cabling Min Max IEC/EN 60947Screw clamp connections Solid conductor mm2 1 x 1.5 2 x 4 1 x 4 + 1 x 2.5

Flexible cable without cable end mm2 1 x 0.75 2 x 4 2 x 2.5

Flexible cable with cable end mm2 1 x 0.34 1 x 1.5 + 1 x 2.5 1 x 1.5 + 1 x 2.5

Spring terminal connections Solid conductor mm2 1 x 0.75 1 x 1.5 2 x 1.5

Flexible conductorwithout cable end mm2 1 x 0.75 1 x 1.5 2 x 1.5

Faston connectors Clip mm 2 x 2.8 or 1 x 6.35

Solder pins for With locating device between powerprinted circuit board and control circuits 4 mm x 35 microns

Tightening torque Philips head n˚ 2 and Ø 6 N.m 0.8…1.3

Terminal referencing Conforming to standards EN 50005 and EN 50012 Up to 3 contacts

Rated insulation voltage (Ui) Conforming to IEC/EN 60947-4-1 V 690

Conforming to VDE 0110 gr C V 750

Conforming to NF C 20-040 V 690

Conforming to CSA 22-2 n˚ 14, UL 508 V 600

Rated impulse withstand voltage kV 8(Uimp)

Protective treatment Conforming to IEC 68 (DIN 50016) “TC” (Klimafest, Climateproof)

Degree of protection Conforming to VDE 0106 Protection against direct finger contact

Ambient air temperature Storage ˚C - 50…+ 80around the device

Operation ˚C - 25…+ 50

Maximum operating altitude Without derating m 2000

Vibration resistance Contactor open 2 gn5...300 Hz

Contactor closed 4 gn

Flame resistance Conforming to UL 94 Self-extinguishing materials V1

Conforming to NF F 16-101 and 16-102 Conforming to requirement 2

Shock resistance Contactor open 10 gn(1/2 sine wave, 11 ms)

Contactor closed 15 gn

Safe circuit separation Conforming to VDE 0106 and IEC 536 VLSV (Very Low Safety Voltage), up to 400 V

ContactorsLow consumption contactors and reversing contactorstype LPp-K

Characteristics

References:pages 2/52 to 2/57

Dimensions, mounting:pages 2/58 and 2/59

Schemes:pages 2/60 and 2/61

Page 32: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/49

2

2.2

ContactorsLow consumption contactors and reversing contactorstype LPp-K

Pole characteristics

Conventional thermal current (Ith) For ambient temperature ≤ 50 ˚C A 20

Rated operational frequency Hz 50/60

Frequency limits ofoperational current Hz Up to 400

Rated operational voltage (Ue) V 690

Rated making capacity I rms conforming to NF C 63-110and IEC/EN 60947-4-1 LPpppp-K06, LPpppp-K09 A 110

LPpppp-K12 A 144

Rated breaking capacity V 220/ 380/ 415 440 500 660/240 400 690

I rms conforming to NF C 63-110and IEC/EN 60947-4-1 LPpppp-K06, LPpppp-K09 A 110 110 110 110 80 70

LPpppp-K12 A – – – 120 80 70

Permissible short time rating In free air for a time “t” 1 s 5 s 10 s 30 s 1 min 3 min ≥ 15 minfrom cold state (θ ≤ 50 ˚C)

LPpppp-K06, LPpppp-K09 A 90 85 80 60 45 40 20

LPpppp-K12 115 105 100 75 55 50 25

Short-circuit protection gG fuse U ≤ 440 V (aM fuse, see page 2/46) A 25

Average impedance per pole At Ith and 50 Hz mΩ 3

Utilisation in category AC-1 Maximum rated operational current A 20resistive circuits, heating, lighting for a temperature ≤ 50 ˚C(Ue ≤ 440 V)(see curve page 1/14) Rated operational current limits in relation On-load factor 90 % 60 % 30 %

to the on-load factor and operating frequencyA 300 op. cycles/hour 13 15 18

120 op. cycles/hour 15 18 19

30 op. cycles/hour 19 20 20

Increase in operational current Apply the following coefficients to the current valuesby paralleling of poles given above. These take into account the often

unbalanced current distribution between poles

2 poles in parallel: K = 1.60

3 poles in parallel: K = 2.25

4 poles in parallel: K = 2.80

Utilisation in category AC-3 Operational powerSquirrel cage motors according to the voltage Voltage 50 or 60 Hz V 115 220 220/ 380/ 440/ 500/ 660/(see curve page 1/18) 240 415 480 600 690

1-ph 1-ph 3-ph 3-ph 3-ph 3-ph 3-ph

LPpppp-K06 kW 0.37 0.75 1.5 2.2 3 3 3

LPpppp-K09 kW 0.55 1.1 2.2 4 4 4 4

LPpppp-K12 kW – – 3 5.5 5.5 4 44 (480)

% utilisation of operational power Op. cycles/h 600 900 1200in relation to the maximum operating rate

Power 100 % 75 % 50 %

Characteristics

References:pages 2/52 to 2/57

Dimensions, mounting:pages 2/58 and 2/59

Schemes:pages 2/60 and 2/61

Page 33: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/50

2

2.2

ContactorsLow consumption contactors and reversing contactorstype LPp-K

Control circuit characteristics

Type LP4 LP5

Rated control circuit V c 12…120voltage (Uc)

Control voltage limits For operation 0.7…1.30 Uc(≤ 50 ˚C) single-voltage coil

For drop-out ≥ 0.10 Uc

Average consumption Inrush W 1.8at 20 ˚C and at Uc

Sealed W 1.8

Heat dissipation W 1.8

Operating time Between coil energisation and:at 20 ˚C and at Uc - opening of the N/C contacts ms 25…35

- closing of the N/O contacts ms 30…40

Between coil de-energisation and:- opening of the N/O contacts ms 10…20- closing of the N/C contacts ms 15…25

Maximum immunityto microbreaks ms 2

Maximum operating rate In operating cycles per hour 3600

Mechanical durability at Uc Wide range, low consumption c coil 30 5In millions of operating cycles

Characteristics (continued)

References:pages 2/52 to 2/57

Dimensions, mounting:pages 2/58 and 2/59

Schemes:pages 2/60 and 2/61

Page 34: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/51

2

2.2

10 000

5000

3000

2000

1000800600500400300

200

1008060

24 48 110 220

440 690 V120

380 50040

16 000

80006000

4000

2c2b

4

1

2a

1000

700

500

300

200

1008060504030

20

1086

12 24 48 110 220 440 600 V

250

200

140

100

50

20

2c

2b

2a

3

4

1 million operating cycles3 million operating cycles10 million operating cyclesOccasional making capacity

1 Breaking limit of contacts valid for:- maximum of 50 operating cyclesat 10 s intervals(breaking current = making currentx cos ϕ 0.7).

2 Electrical durability of contacts for:- 1 million operating cycles (2a)- 3 million operating cycles (2b)- 10 million operating cycles (2c).

3 Breaking limit of contacts valid for:- maximum of 20 operating cyclesat 10 s intervals with current passingfor 0.5 s per operating cycle.

4 Thermal limit.

Auxiliary contact characteristics of contactors and instantaneous contact blocks

Number of contacts On LP4, LP5-K 1

On LA1-K 2 max.

Rated operational voltage (Ue) Up to V 690

Rated insulation voltage (Ui) Conforming to IEC/EN 60947-4-1 V 690

Conforming to VDE 0110 group C V 750

Conforming to CSA C 22-2 n˚ 14 V 600

Conventional rated thermal current (lth) For ambient temperature≤ 50 ˚C A 10

Frequency of operational current Hz Up to 400

Minimum switching capacity U min (DIN 19 240) V 17

I min mA 5

Short-circuit protection Conforming to IEC/EN 60947-5-1 and VDE 0660, A 10gG fuse

Rated making capacity Conforming to IEC/EN 60947-5-1 I rms A 110

Overload current Permissible for 1 s A 80

500 ms A 90

100 ms A 110

Insulation resistance MΩ > 10

Non-overlap distance LA1-K: linked contacts to INRS, BIA and CNA specs. mm 0.5 (see schemes, pages 2/60 and 2/61)

Operational power of contacts a.c. supply, category AC-15 d.c. supply, category DC-13conforming to IEC/EN 60947

Electrical durability (valid up to 3600 operating cyclesper hour) on an inductive load such as the coil of anelectromagnet: making current (cos ϕ 0.7) = 10 timesthe breaking current (cos ϕ 0.4).

Power broken in VA

110/ 220/ 380/ 600/V 24 48 127 230 400 440 690VA 48 96 240 440 800 880 1200VA 17 34 86 158 288 317 500VA 7 14 36 66 120 132 200VA 1000 2050 5000 10 000 14 000 13 000 9000

Tim

e co

nsta

nt

in m

s

ContactorsLow consumption contactors and reversing contactorstype LPp-K

Characteristics

References:pages 2/52 to 2/57

Dimensions, mounting:pages 2/58 and 2/59

Schemes:pages 2/60 and 2/61

Electrical durability (valid up to 1200 operating cyclesper hour) on an inductive load such as the coil of anelectromagnet, without economy resistor, the timeconstant increasing with the load.

Power broken in W

V 24 48 110 220 440 600W 120 80 60 52 51 50W 55 38 30 28 26 25W 15 11 9 8 7 6W 720 600 400 300 230 200

Page 35: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/52

2

2.2

cccc

- Contactor selection according to the utilisation category, see the Technical & Application guide available at www.schneider.co.uk.- Compatible with programmable controller outputs.- LED indicator incorporated (except models LP4-KppppFW3 and LP4-KppppGW3).- Wide range coil (0.7…1.30 Uc), suppressor fitted as standard, consumption 1.8 W.- Mounting on 35 mm 7 rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.

3-pole contactors

- Auxiliary contact blocks and accessories, see pages 2/56 and 2/57.Motor control Number Basic reference. Weightin category AC-3 of Complete with codeMaximum Standard auxiliary indicating controlopera- power ratings contacts circuit voltage (1)tional of 3-phasecurrent motors440 V 220 V 380 V 440/500 V

240 V 415 V 660/690 VA kW kW kW N/O N/C kg

Screw clamp connections

6 1.5 2.2 3 1 – LP4-K0610pppppppppppp 0.235

– 1 LP4-K0601pppppppppppp 0.235

9 2.2 4 4 1 – LP4-K0910pppppppppppp 0.235

– 1 LP4-K0901pppppppppppp 0.235

12 3 5.5 4 (> 440) 1 – LP4-K1210pppppppppppp 0.2355.5 (440)

– 1 LP4-K1201pppppppppppp 0.235

Spring terminal connections

6 1.5 2.2 3 1 – LP4-K06103pppppppppppp 0.235

– 1 LP4-K06013pppppppppppp 0.235

9 2.2 4 4 1 – LP4-K09103pppppppppppp 0.235

– 1 LP4-K09013pppppppppppp 0.235

12 3 5.5 4 (> 440) 1 – LP4-K12103pppppppppppp 0.2355.5 (440)

– 1 LP4-K12013pppppppppppp 0.235

Faston connectors, 1 x 6.35 or 2 x 2.8

6 1.5 2.2 3 1 – LP4-K06107pppppppppppp 0.235

– 1 LP4-K06017pppppppppppp 0.235

9 2.2 4 4 1 – LP4-K09107pppppppppppp 0.235

– 1 LP4-K09017pppppppppppp 0.235

12 3 5.5 4 (> 440) 1 – LP4-K12107pppppppppppp 0.2355.5 (440)

– 1 LP4-K12017pppppppppppp 0.235Solder pins for printed circuit boards

6 1.5 2.2 3 1 – LP4-K06105pppppppppppp 0.265

– 1 LP4-K06015pppppppppppp 0.265

9 2.2 4 4 1 – LP4-K09105pppppppppppp 0.265

– 1 LP4-K09015pppppppppppp 0.265

12 3 5.5 4 (> 440) 1 – LP4-K12105pppppppppppp 0.2655.5 (440)

– 1 LP4-K12015pppppppppppp 0.265(1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Volts c 12 20 24 48 72 110 120Code JW3 ZW3 BW3 EW3 SW3 FW3 GW3

References ContactorsLow consumption contactors for motor control, 6 to 12 A in utilisationcategories AC-3 and AC-4Control circuit: d.c.

LP4-K06105ppp

Characteristics:pages 2/48 to 2/51

Dimensions, mounting:pages 2/58 and 2/59

Schemes:pages 2/60 and 2/61

Page 36: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/53

2

2.2

cccc

- Contactor selection according to the utilisation category, see the Technical & Application guide available at www.schneider.co.uk.- Compatible with programmable controller outputs.- LED indicator incorporated (except models LP4-KppppFW3 and LP4-KppppGW3).- Wide range coil (0.7…1.30 Uc), suppressor fitted as standard, consumption 1.8 W.- Mounting on 35 mm 7 rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/56 and 2/57.

3 or 4-pole contactors (1)

Non Number Instantaneous Basic reference. Weightinductive of auxiliary complete with codeloads poles contacts indicating controlCat. AC-1 circuit voltage (2)� � 50 ˚CMaximumcurrent

A N/O N/C kg

Screw clamp connections

20 3 – 1 – LP4-K0910pppppppppppp 0.235or LP4-K1210pppppppppppp 0.235

– 1 LP4-K0901pppppppppppp 0.235or LP4-K1201pppppppppppp 0.235

4 – – – LP4-K09004pppppppppppp 0.235or LP4-K12004pppppppppppp 0.235

2 2 – – LP4-K09008pppppppppppp 0.235

Spring terminal connections

20 3 – 1 – LP4-K09103pppppppppppp 0.235or LP4-K12103pppppppppppp 0.235

– 1 LP4-K09013pppppppppppp 0.235or LP4-K12013pppppppppppp 0.235

4 – – – LP4-K090043pppppppppppp 0.235or LP4-K120043pppppppppppp 0.235

2 2 – – LP4-K090083pppppppppppp 0.235

Faston connectors, 1 x 6.35 or 2 x 2.8

20 3 – 1 – LP4-K09107pppppppppppp 0.235or LP4-K12107pppppppppppp 0.235

– 1 LP4-K09017pppppppppppp 0.235or LP4-K12017pppppppppppp 0.235

4 – – – LP4-K090047pppppppppppp 0.235or LP4-K120047pppppppppppp 0.235

2 2 – – LP4-K090087pppppppppppp 0.235Solder pins for printed circuit boards

20 3 – 1 – LP4-K09105pppppppppppp 0.265or LP4-K12105pppppppppppp 0.235

– 1 LP4-K09015pppppppppppp 0.265or LP4-K12015pppppppppppp 0.235

4 – – – LP4-K090045pppppppppppp 0.265or LP4-K120045pppppppppppp 0.235

2 2 – – LP4-K090085pppppppppppp 0.265(1) Selection to be made according to the number of operating cycles, see AC-1 curve in the Technical & Applicationguide available at www.schneider.co.uk.(2) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).Volts c 12 20 24 48 72 110 120Code JW3 ZW3 BW3 EW3 SW3 FW3 GW3

ContactorsLow consumption contactors for control in utilisation category AC-1, 20 AControl circuit: d.c.

References

Characteristics:pages 2/48 to 2/51

Dimensions, mounting:pages 2/58 and 2/59

Schemes:pages 2/60 and 2/61

LP4-K090047ppp

Page 37: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/54

2

2.2

- Contactor selection according to the utilisation category, see the Technical & Application guide available atwww.schneider.co.uk.- Compatible with programmable controller outputs.- LED indicator incorporated (except models LP5-KppppFW3 and LP5-KppppGW3).- Wide range coil (0.7…1.30 Uc), suppressor fitted as standard, consumption 1.8 W.- Mechanical interlock incorporated.It is essential to link the contacts of the electrical interlock.- Pre-wired power circuit connections as standard on screw clamp versions.- Mounting on 35 mm 7 rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/56 and 2/57.

(1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).

3-pole reversing contactors

Motor control Number Basic reference. Weightin category AC-3 of Complete with codeMaximum Standard auxiliary indicating controlopera- power ratings contacts circuit voltage (1)tional of 3-phasecurrent motors440 V 220 V 380 V 440/500 V

240 V 415 V 660/690 VA kW kW kW N/O N/C kg

Screw clamp connections

6 1.5 2.2 3 1 – LP5-K0610pppppppppppp 0.490– 1 LP5-K0601ppp 0.490

9 2.2 4 4 1 – LP5-K0910ppp 0.490– 1 LP5-K0901ppp 0.490

12 3 5.5 4 (> 440) 1 – LP5-K1210ppp 0.4905.5 (440) – 1 LP5-K1201ppp 0.490

Spring terminal connections

6 1.5 2.2 3 1 – LP5-K06103ppp 0.490– 1 LP5-K06013ppp 0.490

9 2.2 4 4 1 – LP5-K09103ppp 0.490– 1 LP5-K09013ppp 0.490

12 3 5.5 4 (> 440) 1 – LP5-K12103ppp 0.4905.5 (440) – 1 LP5-K12013ppp 0.490

Faston connectors, 1 x 6.35 or 2 x 2.8

6 1.5 2.2 3 1 – LP5-K06107ppp 0.470– 1 LP5-K06017ppp 0.470

9 2.2 4 4 1 – LP5-K09107ppp 0.470– 1 LP5-K09017ppp 0.470

12 3 5.5 4 (> 440) 1 – LP5-K12107ppp 0.4705.5 (440) – 1 LP5-K12017ppp 0.470

Solder pins for printed circuit boards

6 1.5 2.2 3 1 – LP5-K06105ppp 0.530– 1 LP5-K06015ppp 0.530

9 2.2 4 4 1 – LP5-K09105ppp 0.530– 1 LP5-K09015ppp 0.530

12 3 5.5 4 (> 440) 1 – LP5-K12105ppp 0.5305.5 (440) – 1 LP5-K12015ppp 0.530

Volts c 12 20 24 48 72 110 120Code JW3 ZW3 BW3 EW3 SW3 FW3 GW3

LP5-K06105ppp

ContactorsLow consumption reversing contactorsfor motor control, 6 to 12 A in utilisationcategories AC-3 and AC-4Control circuit: d.c.

References

cccc

Characteristics:pages 2/48 to 2/51

Dimensions, mounting:pages 2/58 and 2/59

Schemes:pages 2/60 and 2/61

Page 38: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/55

2

2.2

- Warning: reversing contactors LP5-K0910pppppppp and LP5-K0901pppppppp are pre-wired for reverse motor operation- Reversing contactor selection according to the utilisation category, see the Technical & Application guide available at

www.schneider.co.uk.- Compatible with programmable controller outputs.- LED indicator incorporated (except models LP5-KppppFW3 and LP5-KppppGW3).- Wide range coil (0.7…1.30 Uc), suppressor fitted as standard, consumption 1.8 W.- Mechanical interlock incorporated.It is essential to link the contacts of the electrical interlock.- Pre-wired power circuit connections as standard on screw clamp versions.- Mounting on 35 mm 7 rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.- Auxiliary contact blocks and accessories, see pages 2/56 and 2/57.

(1) Selection to be made according to the number of operating cycles, see AC-1 curve in the Technical & Applicationguide available at www.schneider.co.uk.(2) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).

3 or 4-pole reversing contactors (1)

Non Type of Number Instantaneous Basic reference. Weightinductive connection of auxiliary Complete with codeloads poles contacts indicating controlCat. AC-1 circuit voltage (2)θ ≤ 50 ˚CMaximumcurrent

A N/O N/C kg

Screw clamp connections

20 3 – 1 – LP5-K0910ppp 0.490or LP5-K1210ppp 0.490

3 – – 1 LP5-K0901ppp 0.490or LP5-K1201ppp 0.49

4 – – – LP5-K09004ppp 0.490or LP5-K12004ppp 0.490

Spring terminal connections

20 3 – 1 – LP5-K09103ppp 0.490or LP5-K12103ppp 0.490

3 – – 1 LP5-K09013ppp 0.490or LP5-K12013ppp 0.490

4 – – – LP5-K090043ppp 0.490or LP5-K120043ppp 0.490

Faston connectors, 1 x 6.35 or 2 x 2.8

20 3 – 1 – LP5-K09107ppp 0.470or LP5-K12107ppp 0.490

3 – – 1 LP5-K09017ppp 0.470or LP5-K12017ppp 0.490

4 – – – LP5-K090047ppp 0.470or LP5-K120047ppp 0.490

Solder pins for printed circuit boards

20 3 – 1 – LP5-K09105ppp 0.530or LP5-K12105ppp 0.490

3 – – 1 LP5-K09015ppp 0.530or LP5-K12015ppp 0.490

4 – – – LP5-K090045ppp 0.530or LP5-K120045pppppppppppp 0.490

Volts c 12 20 24 48 72 110 120Code JW3 ZW3 BW3 EW3 SW3 FW3 GW3

ContactorsLow consumption reversing contactorsfor control in utilisation category AC-1, 20 AControl circuit: d.c.

References

Characteristics:pages 2/48 to 2/51

Dimensions, mounting:pages 2/58 and 2/59

Schemes:pages 2/60 and 2/61

LP5-K0910ppp

Page 39: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/56

2

2.2

Clip-on front mounting, 1 block per contactor

Clip-on front mounting, 1 block per contactor

- Relay output, with common point changeover contact, a or c 240 V, 2 A maximum.- Control voltage: 0.85…1.1 Uc.- Maximum switching capacity: 250 VA or 150 W.- Operating temperature: -10…+ 60 ˚C.- Reset time: 1.5 s during the time delay period, 0.5 s after the time delay period.

Clip-on front mounting, 1 block per contactor

Instantaneous auxiliary contact blocks

Type of Type of Composition Reference Weightconnection contactor

N/O N/C kg

Screw clamp 3 or 4-pole 2 – LA1-KN20 0.045

– 2 LA1-KN02 0.045

1 1 LA1-KN11 0.045

Spring terminal 3 or 4-pole 2 – LA1-KN203 0.045

– 2 LA1-KN023 0.045

1 1 LA1-KN113 0.045

Faston connectors 3 or 4-pole 2 – LA1-KN207 0.0451 x 6.35or 2 x 2.8

– 2 LA1-KN027 0.045

1 1 LA1-KN117 0.045

Instantaneous auxiliary contact blocks (with terminal referencing conforming to EN 50012)

Screw clamp 3-pole. – 2 LA1-KN02M 0.045with terminal 6 or 9 Areferencingconforming to 1 1 LA1-KN11M 0.045standard EN 50012

4-pole, 9 A 1 1 LA1-KN11P 0.045

Electronic time delay auxiliary contact blocks

Voltage Type Timing Composition Reference Weightrange

V s C/O kg

a or c 24…48 On-delay 1…30 1 LA2-KT2E 0.040

a 110…240 On-delay 1…30 1 LA2-KT2U 0.040

References

LA1-KN20

ContactorsLow consumption contactors and reversing contactorstype LPp-KInstantaneous and time delay auxiliary contacts

LA2-KT2p

Characteristics:pages 2/48 to 2/51

Dimensions, mounting:pages 2/58 and 2/59

Schemes:pages 2/60 and 2/61

LA1-KN113

Page 40: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/57

2

2.2

(1) Order 1 mounting plate for fixing a contactor and 2 mounting plates for fixing a reversing contactor.(2) Complete the reference by replacing the p with the required character.

Mounting and marking accessories

Description Application Sold in Unit Weightlots of reference kg

Mounting For fixing Clip-on 1 LA9-D973 0.025plates (1) on 1 4 rail

For fixing 110/120 mm 10 DX1-AP25 0.065on 2 4 rails fixing centres

Marker Clip-on Onto front 100 LA9-D90 0.001holder of contactor

Clip-in 4 maximum Strips of 25 AB1-Rpppp (2) 0.002markers per contactor 10 identical

numbers 0…9

Strips of 25 AB1-Gpppp (2) 0.00210 identicalcapitalletters A…Z

Cabling accessories

Description Application Sold in Unit Weightlots of reference kg

Paralleling For 2 poles With screw 4 LA9-E01 0.010links clamp terminals

For 4 poles With screw 2 LA9-E02 0.015clamp terminals

Set of 6 power For 3-pole For contactors 100 LA9-K0969 0.010connections reversing with screw

contactors for clamp terminalsmotor control

Set of 4 power For 4-pole For contactors 100 LA9-K0970 0.010connections changeover with screw

contactor pairs clamp terminals

ContactorsLow consumption contactors and reversing contactorstype LPp-KMounting, marking and cabling accessories

References

Characteristics:pages 2/48 to 2/51

Dimensions, mounting:pages 2/58 and 2/59

Schemes:pages 2/60 and 2/61

LA9-E01

DX1-AP25

Page 41: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/58

2

2.2

57

58

45

110

45

120

57 27

DZ5-ME5

45

35= =

505

557 21

5735

LA1-K

58 50=

=

35

45

= =

50 53

45

58

8,65 = = = A1

A2

38 38

27

57

LA2-KT

58

38

ContactorsLow consumption contactors and reversing contactors type LPp-K

Electronic time delay contact blocks

Contactors LP4-KOn panel On mounting rail AM1-DP200 or AM1 DE200 (7 35 mm)

On one asymmetrical rail DZ5-MB with clip-on mounting plateLA9-D973 DX1-AP25

On printed circuit board

(Pin Ø 1.55)

LA2-KT On contactor

Dimensions,mounting

Characteristics:pages 2/48 to 2/51

References:pages 2/52 to 2/57

Schemes:pages 2/60 and 2/61

Page 42: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/59

2

2.2

57

58

90

90

35= =

505

557 21

57 27

DZ5-ME5

90

110

120

5735

LA1-K

58 50=

=

90

80 ==

45

58

8,65 = = =

A1

A2 50

45

8,65===

53

A1

A2

38 38

27

57

LA2-KT

58

38

LP5-K

On one asymmetrical rail DZ5-MB with 2 clip-on mounting plates LA9-D973 or two mounting plates DX1-AP25.

On printed circuit board for reversing contactors or 2 contactors mounted side by side

(Pin Ø 1.55)

Electronic time delay contact blocks

Reversing contactors

On panel On mounting rail AM1-DP200 or AM1-DE200 ( 7 35 mm)

2 x LA9-D973 2 x DX1-AP25

LA2-KT On reversing contactors

ContactorsLow consumption contactors and reversing contactors type LPp-K

Dimensions,mounting

Characteristics:pages 2/48 to 2/51

References:pages 2/52 to 2/57

Schemes:pages 2/60 and 2/61

Page 43: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/60

2

2.2 13/N

O14

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

13/N

O14

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

13/N

O14

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

13/N

O14

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

21/N

C22

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

21/N

C22

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

13/N

O14

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6 2221

/NC

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

A1

A2

1815

16

21/N

C22

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

21/N

C22

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

+A

1–A

2+

A1

–A2

61/N

C62

53/N

O54

53/N

O54

63/N

O64

61/N

C62

51/N

C52

22 34

21/N

C

33/N

O

31/N

C32

21/N

C22

With screw clamp terminals

With Faston connectors or solder pins for printed circuit boards

Instantaneous auxiliary contact blocksLA1-K

Electronic time delay contact blocksLA2-KTFor 3-pole contactors LPpppp-K1 C/O

3-pole contactors Integral suppression deviceLP4-K LP4-K3-pole + N/O 3-pole + N/C

3-pole reversing contactors Integral suppression deviceLP5-K LP5-K

3-pole + N/O 3-pole + N/C

3-pole + N/O 3-pole + N/C

For 3-pole contactors LPpppp-K Terminal referencing conforming to standard EN 500122 N/O 2 N/C 1 N/O + 1 N/C 2 N/C 1 N/O + 1 N/CLA1-KN20 LA1-KN02 LA1-KN11 LA1-KN02M LA1-KN11MLA1-KN207 LA1-KN027 LA1-KN117

ContactorsLow consumption contactors and reversing contactors type LPp-K

Schemes

Characteristics:pages 2/48 to 2/51

References:pages 2/52 to 2/57

Dimensions, mounting:pages 2/58 and 2/59

Page 44: Characteristics Contactors - RS Components · 2019. 10. 13. · LC p -K06, LP p -K06, LC p -K09, LP p -K09 A 90 85 80 60 45 40 20 LC p -K12, LP p -K12 A 115 105 100 75 55 50 25 Short-circuit

2/61

2

2.2

R1

R2

A1

A2

12

34

R3

R4

A1

A2

12

34

56

A1

A2

12

34

56

1/L1

1/L2

1/L3

2/L1

2/L2

2/L3

L1 L2 L3

78

1N

78

2NN

A1

A2

12

34

56

A1

A2

12

34

78

78

56

A1

A2

1/L1

T1/

2

3/L2

T2/

4

5/L3

T3/

6

7/L4

T4/

8

+A

1–A

2+

A1

–A2

61/N

C62

51/N

C52

61/N

C62

53/N

O54

53/N

O54

63/N

O64

21/N

C22

13/N

O14

A1

A2

1815

16

ContactorsLow consumption contactors and reversing contactors type LPp-K

Instantaneous auxiliary contact blocksLA1-KFor 4-pole contactors LPp-K

Electronic time delay contact blocksLA2-KTFor 4-pole contactors LPp-K1 C/O

4-pole contactors Integral suppression deviceLP4-K LP4-K 4 P 2 P N/O + 2 P N/C

4-pole reversing contactors Integral suppression deviceLP5-K LP5-KWith screw clamp connections With Faston connectors or

solder pins for printed circuit board4 P 4 P

2 N/O 2 N/C 1 N/O + 1 N/C Terminal referencing conforming to EN 50012LA1-KN20 LA1-KN02 LA1-KN11 1 N/O + 1 N/CLA1-KN207 LA1-KN027 LA1-KN117 LA1-KN11P

Schemes

Characteristics:pages 2/48 to 2/51

References:pages 2/52 to 2/57

Dimensions, mounting:pages 2/58 and 2/59