Chapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including FRU names, and connectors. How to translate a location code 1. Understand the two part structure of the location code: v The first part is called the Machine Type/Model/Serial Number (MTMS) and identifies the rack or enclosure within a rack. The rack or enclosure will have a bar code label with the MTMS visible by the service representative. v The second part is the specific FRU location within that rack or enclosure. 2. Use the table below to translate your location code MTMS to a part of the DS8000. Note: mmm = rack model (ex: 921) ssssss = serial number Table 260. Location code translation MTMS Description MTMS label location Second part of Location Code 2107.mmm.ssssss0 2107 Rack (DS8000) On the rack operator panel, below the UEPO red switch cover. “Rack power and cooling location codes” on page 1125 U2107.mmm.ssssssy (y=1, 2) Storage Facility Image (SFI) (The SFI is not a physical FRU, it is a Logical Partition on the CEC enclosure. ) U2107.D01.sssssss Storage enclosure On the front of the storage enclosure, at the far right in between the rack mounting screws. (In a vertical orientation.) “Storage enclosure location codes” on page 1140 9117-570*sssssss CEC complex (1 or more than 1 CEC enclosure cabled together and controlled by the service processor in the first CEC enclosure.) On the front of the CEC enclosure, on the operator panel. “CEC enclosure location codes” on page 1116 U7879.001.sssssss CEC enclosure (A CEC complex may have more than one CEC enclosure, each with a unique ssssss.) On the front of the CEC enclosure, at the far right in between the rack mounting screws. (In a vertical orientation.) “CEC enclosure location codes” on page 1116 © Copyright IBM Corp. 2004, 2005 1115

Upload: others

Post on 15-Apr-2020

49 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Chapter 42. Location codes

This section contains the system drawings and associated descriptive tables with

location code information, including FRU names, and connectors.

How to translate a location code

1. Understand the two part structure of the location code:

v The first part is called the Machine Type/Model/Serial Number (MTMS) and

identifies the rack or enclosure within a rack. The rack or enclosure will have

a bar code label with the MTMS visible by the service representative.

v The second part is the specific FRU location within that rack or enclosure.

2. Use the table below to translate your location code MTMS to a part of the

DS8000.

Note:

mmm = rack model (ex: 921)

ssssss = serial number

Table 260. Location code translation

MTMS Description MTMS label location

Second part of

Location Code

2107.mmm.ssssss0 2107 Rack (DS8000) On the rack operator

panel, below the

UEPO red switch

cover.

“Rack power and

cooling location

codes” on page 1125

U2107.mmm.ssssssy

(y=1, 2)

Storage Facility

Image (SFI)

(The SFI is not a

physical FRU, it is a

Logical Partition on

the CEC enclosure. )

U2107.D01.sssssss Storage enclosure On the front of the

storage enclosure, at

the far right in

between the rack

mounting screws. (In

a vertical orientation.)

“Storage enclosure

location codes” on

page 1140

9117-570*sssssss CEC complex (1 or

more than 1 CEC

enclosure cabled

together and

controlled by the

service processor in

the first CEC

enclosure.)

On the front of the

CEC enclosure, on

the operator panel.

“CEC enclosure

location codes” on

page 1116

U7879.001.sssssss CEC enclosure (A

CEC complex may

have more than one

CEC enclosure, each

with a unique

ssssss.)

On the front of the

CEC enclosure, at

the far right in

between the rack

mounting screws. (In

a vertical orientation.)

“CEC enclosure

location codes” on

page 1116

© Copyright IBM Corp. 2004, 2005 1115

Page 2: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 260. Location code translation (continued)

MTMS Description MTMS label location

Second part of

Location Code

U1300.001.sssssss I/O enclosure On the front of the

I/O enclosure, at the

bottom of the left I/O

enclosure power

supply.

“I/O enclosure

location codes” on

page 1121

8676.mmm.sssssss HMC server On the front of the

HMC server, at the

far right near the

thumb screw. (In a

vertical orientation.)

Use the HMC server

maintenance guide

on the documentation

CD.

CEC enclosure location codes

The list below summarizes the CEC enclosure assembly with figures and related

tables that contain location code information. For part numbers, see “CEC

enclosure part numbers” on page 1049.

Table 261.

Assembly Reference

CEC enclosure front overview Figure 532 on page 1117

CEC enclosure front locations Figure 533 on page 1117

CEC enclosure rear overview Figure 534 on page 1119

CEC enclosure rear locations Figure 535 on page 1119

CEC enclosure memory DIMM

locations

Figure 536 on page 1121

CEC enclosure front overview

1116 IBM TotalStorage DS8000: Service Guide

Page 3: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 262. CEC enclosure front locations

Location code FRU name Connector CCIN

U7879.001.sssssss-A1 CEC enclosure fan

U7879.001.sssssss-A2 CEC enclosure fan

U7879.001.sssssss-D1 CEC enclosure control panel 28D4

U7879.001.sssssss-P2 System processor backplane

assembly

27AE

U7879.001.sssssss-P2-C1 System processor card

1.5 GHz

1.9 GHz nominal voltage

1.9 GHz high voltage

26EF

272E

272F

U7879.001.sssssss-P2-C1-T1

SMP V-bus

1xxayd

P4

P2 P3

P2-C1 P2-C2

D1P4-D1P4-D2

P2-C

3

P2-C

4

P2-C

5

P1-T

14-L

5-L

0

P1-T

14-L

4-L

0

P1-T

14-L

3-L

0

P1-T

12-L

5-L

0

P1-T

12-L

4-L

0

P1-T

12-L

3-L

0

Front View

Figure 532. CEC enclosure locations (front overview)

P3

P1-C9

D1

D2

D3

D4

D5

D6

P4

RM1 P4-D1

RM2 P4-D2PowerAttn/Identify

P2-C1-T1 P2-C2-T1P2-C3

P2-C4

P2-C5 1xxand

P4-D2P4-D1

A1D1 A2

P2-C2P2-C1

Figure 533. CEC enclosure locations (front)

Chapter 42. Location codes 1117

Page 4: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 262. CEC enclosure front locations (continued)

Location code FRU name Connector CCIN

U7879.001.sssssss-P2-C1-Cx

memory DIMM - 2 GB

memory DIMM - 8 GB

(x = slot 1-8, top to bottom)

30AA

30F7

U7879.001.sssssss-P2-C2 System processor card

1.5 GHz

1.9 GHz nominal voltage

1.9 GHz high voltage

26EF

272E

272F

U7879.001.sssssss-P2-C2-T1

SMP V-bus

U7879.001.sssssss-P2-C2-Cx

memory DIMM - 2 GB

memory DIMM - 8 GB

(x = slot 1-8, top to bottom)

30AA

30F7

U7879.001.sssssss-P2-C3 System processor voltage card 28E8

U7879.001.sssssss-P2-C4 System processor voltage card 28E8

U7879.001.sssssss-P2-C5 System processor voltage card 28E8

U7879.001.sssssss-P3 CEC disk drive backplane

assembly

28DB

U7879.001.sssssss-P1-T14-L5-L0

73 GB 15K RPM Disk Drive

U7879.001.sssssss-P1-T14-L4-L0

73 GB 15K RPM Disk Drive

U7879.001.sssssss-P1-T14-L3-L0

73 GB 15K RPM Disk Drive

U7879.001.sssssss-P1-T12-L5-L0

73 GB 15K RPM Disk Drive

U7879.001.sssssss-P1-T12-L4-L0

73 GB 15K RPM Disk Drive

U7879.001.sssssss-P1-T12-L3-L0

73 GB 15K RPM Disk Drive

U7879.001.sssssss-P4 Media backplane assembly 28DC

U7879.001.sssssss-P4-D1 DVD-RAM drive (top)

U7879.001.sssssss-P4-D2 not used (bottom)

CEC enclosure rear overview

1118 IBM TotalStorage DS8000: Service Guide

Page 5: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 263. CEC enclosure rear locations

Location code FRU name Connector CCIN

U7879.001.sssssss-P1 CEC enclosure I/O

backplane assembly

27AE

U7879.001.sssssss-P1-T1 Serial 2

U7879.001.sssssss-P1-T2 Serial 1

U7879.001.sssssss-P1-T3 unused

U7879.001.sssssss-P1-T4 USB 1

U7879.001.sssssss-P1-T5 USB 2

U7879.001.sssssss-P1-T6 Ethernet 1

U7879.001.sssssss-P1-T7 Ethernet 2

U7879.001.sssssss-P1-T8 HSL/RIO 0

U7879.001.sssssss-P1-T9 HSL/RIO 1

U7879.001.sssssss-P1-T10 System connector

U7879.001.sssssss-P1-C1 NVC card

f2c00137

P1-C

1

P1-C

2

P1-C

3

P1-C

4

P1-C

5

P1-C

6/P

1-C

7

P1-C

8

E1 E2

P1

Back View

Figure 534. CEC enclosure locations (rear overview)

P1-C8-T1

P1-C8-T2

P1-C8-T3

P1-C8-T4

P1-C10

P1-T1

P1-T2

P1-T3

P1-C7-T1

P1-C7-T2

P1-C6/P1-C7 (optional)P1-C1

P1-C2

P1-C3

P1-C4

P1-C5

P1-T4

P1-T5

P1-T7

P1-T6

P1-T8

E1 E2

P1-T9 P1-T10

1xxanb

Figure 535. CEC enclosure locations

Chapter 42. Location codes 1119

Page 6: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 263. CEC enclosure rear locations (continued)

Location code FRU name Connector CCIN

U7879.001.sssssss-P1-C2 not used

U7879.001.sssssss-P1-C3 not used

U7879.001.sssssss-P1-C4 Ethernet card (optional) 5706

U7879.001.sssssss-P1-C4-T1 (top connector)

U7879.001.sssssss-P1-C4-T2 (bottom connector)

U7879.001.sssssss-P1-C5 NVC card (optional)

U7879.001.sssssss-P1-C7 CEC enclosure RIO card

(optional)

1800

U7879.001.sssssss-P1-C7-T1 HSL/RIO 0

U7879.001.sssssss-P1-C7-T2 HSL/RIO 1

U7879.001.sssssss-P1-C8 System processor card

1.5 GHz

1.9 GHz nominal voltage

1.9 GHz high voltage

26EF

272E

272F

U7879.001.sssssss-P1-C8-T1 Ethernet

U7879.001.sssssss-P1-C8-T2 Ethernet

U7879.001.sssssss-P1-C8-T3 SPCN 0

U7879.001.sssssss-P1-C8-T4 SPCN 1

U7879.001.sssssss-P1-C10 VPD card 528E

U7879.001.sssssss-E1 CEC enclosure power

supply

U7879.001.sssssss-E2 CEC enclosure power

supply

1120 IBM TotalStorage DS8000: Service Guide

Page 7: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

CEC enclosure memory DIMM locations

Table 264. CEC enclosure memory DIMM locations

Location code FRU name CCIN

P2-Cx-Cy

x = System backplane slot 1 or 2

y = Memory DIMM slot 1 - 8 as shown

Memory DIMM - 2 GB

Memory DIMM - 8 GB

30AA

30F7

I/O enclosure location codes

The list below summarizes the I/O enclosure figures and related tables that contain

location code information and part numbers. For part numbers, see “I/O enclosure

part numbers” on page 1062.

Table 265.

Assembly Reference

I/O enclosure front locations Figure 537 on page 1122

I/O enclosure rear locations Figure 538 on page 1123

I/O enclosure adapter locations Figure 539 on page 1124

I/O enclosure front locations

C1C2C3C4

C5C6C7C8

J0DJ0CJ0BJ0A

J1AJ1BJ1CJ1D

1xxan6

Location P2 - Cx - Cyx= System Backplane slot 1 or 2y= Memory Dimm slot 1 thru 8 as shown

Memory Quad 1= C1,C3,C6,C8Memory Quad 2= C2,C4,C5,C7

Figure 536. CEC memory DIMM card locations

Chapter 42. Location codes 1121

Page 8: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 266. I/O enclosure front locations

Location code FRU name Connector CCIN

U1300.001.sssssss-A1 I/O enclosure fan

U1300.001.sssssss-E1 I/O enclosure power

supply

U1300.001.sssssss-E2 I/O enclosure power

supply

I/O enclosure rear locations

1xxayb

A1

E1 E2

Figure 537. I/O enclosure locations (front)

1122 IBM TotalStorage DS8000: Service Guide

Page 9: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

1xxaya

P1-T1

P1-T2

P1-T3 P1-C

1

P1-C

2

P1-C

3

P1-C

7-0

1P

1-C

7-0

0

P1-C

4

P1-C

5

P1-C

6

P1-C7

Figure 538. I/O enclosure locations (rear)

Chapter 42. Location codes 1123

Page 10: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 267. I/O enclosure rear with adapters locations

Location code FRU name Connector CCIN

U1300.001.sssssss I/O enclosure

U1300.001.sssssss-P1 I/O enclosure backplane

U1300.001.sssssss-P1-Cx (x =

1, 2, 4, 5)

ESCON host card

U1300.001.sssssss-P1-Cx-Ty

(x = 1, 2, 4, 5)

ESCON Cable

U1300.001.sssssss-P1-Cx (x =

1, 2, 4, 5)

Fibre channel host card

(short wave and long

wave)

U1300.001.sssssss-P1-Cx-Ty

(x = 1, 2, 4, 5)

FCAL cable

1w

i5im

HostBays

Rear View

Fiber Channel Host Card

P1-Cx-T0

P1-Cx-T1P1-Cx-T2P1-Cx-T3

Escon Host Card

P1-Cx-T0

P1-Cx-T1

Device Adapter Card

P1-Cx-T0

P1-Cx-T1

P1-Cx-T2

P1-Cx-T3

Figure 539. I/O enclosure adapter locations

1124 IBM TotalStorage DS8000: Service Guide

Page 11: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 267. I/O enclosure rear with adapters locations (continued)

Location code FRU name Connector CCIN

U1300.001.sssssss-P1-Cx (x =

3, 6)

Device adapter card

U1300.001.sssssss-P1-Cx-Ty

(x = 3, 6)

FCAL cable

U1300.001.sssssss-P1-C7 I/O enclosure RIO card

U1300.001.sssssss-P1-C7-00 RIO (top)

U1300.001.sssssss-P1-C7-01 RIO (bottom)

U1300.001.sssssss-P1-T1 Rack identity card

cable

U1300.001.sssssss-P1-T2 SPCN 0

U1300.001.sssssss-P1-T3 SPCN 1

Rack power and cooling location codes

The list below summarizes the rack and power figures and related tables that

contain location code information. For part numbers, see “Rack power and cooling

part numbers” on page 1071.

Assembly Reference

Rack locations overview Figure 540 on page 1126

Storage expansion rack locations

overview

Figure 541 on page 1127

Primary power supply (PPS) Figure 542 on page 1128

PPS front, no fans Figure 543 on page 1129

5/12V DDM power module Figure 544 on page 1131

AC input power module Figure 545 on page 1132

Sequence module Figure 546 on page 1133

Battery module set Figure 547 on page 1134

DASD fan tray assembly Figure 548 on page 1135

Fan sense card Figure 549 on page 1136

Local remote switch card Figure 550 on page 1137

Rack identity card Figure 551 on page 1137

RPC card Figure 552 on page 1139

zSeries local remote switch card Figure 553 on page 1140

Chapter 42. Location codes 1125

Page 12: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Rack locations overview

Table 268. Rack overview locations

Location code FRU name

E10 thru E12 Battery module chassis

E1 and E2 Primary power supply

U7879.001.ssssss CEC enclosure

U1300.001.sssssss I/O enclosure

U2107.D01.sssssss Storage enclosure

Front View

Fans/PlenumFan SenseFront

Fan SenseRear

RPC’s

PPS 1

E1

PPS 2

E2

StorageEnclosure

StorageEnclosure

StorageEnclosure

StorageEnclosure

CECEnclosure

CECEnclosure

Battery

Battery

Battery

2107 Rack-1

Rear View

Fans/Plenum

PPS

E1

PPS

E2

StorageEnclosure

StorageEnclosure

StorageEnclosure

StorageEnclosure

CECEnclosure

CECEnclosure

Battery

Battery

Battery

IO/Encl

IO/Encl

IO/Encl

IO/Encl

IO/EnclIO/Encl

IO/EnclIO/Encl

E10

E11

E12

U2107.D01.sssssss

U7879.001.sssssss

U1300.001.sssssss

1y1

6xn

Figure 540. Primary power supply rack locations (overview)

1126 IBM TotalStorage DS8000: Service Guide

Page 13: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

PPS storage expansion rack locations

Table 269. Storage expansion rack locations

Location code FRU name

E10 thru E12 Battery module

E1 and E2 Primary power supply

U1300.001.sssssss I/O enclosure

U2107.D01.sssssss Storage enclosure

Front View

Fans/PlenumFan SenseFront

Fan SenseRear

PPS

E1

PPS

E2

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

16 PackFront & Rear

Battery

Battery

Battery

2107 Storage Expansion Rack

Rear View

Fans/Plenum

PPS

E1

PPS

E2

Battery

Battery

Battery

IO/Encl

IO/Encl

IO/Encl

IO/Encl

IO/EnclIO/Encl

IO/EnclIO/Encl

1y16xp

E10

E11

E12

U2107.D01.sssssss

U1300.001.sssssss

Figure 541. Storage expansion rack locations

Chapter 42. Location codes 1127

Page 14: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Primary power supply locations

Table 270. Primary power supply locations

Location code FRU name Connector

U2107.mmm.sssssss-Ex

x = 1 top PPS

x = 2 bottom PPS

Primary power supply

(PPS) includes:

v AC input power module

(rear bottom left)

v Sequence module (rear

bottom right)

v 5/12V DDM power

module (rear center left)

v 208VDC base module

(front left)

v PFC module (front right)

U2107.mmm.sssssss-Ex-A1 PPS fan (top) Power/signal

U2107.mmm.sssssss-Ex-A2 PPS fan (middle) Power/signal

U2107.mmm.sssssss-Ex-A3 PPS fan (bottom) Power/signal

U2107.mmm.sssssss-Ex-E1 5/12V DDM power module

1xxay5

Rear

Ex-E1Ex-E3

SequenceModule

AC InputModule

Ex-E2

Ex x=1 Top PPS2 Bottom PPS

Primary Power Supply

Front

Ex-A1

(J15)(J14)

(J13)

Ex-A2

Ex-A3

Figure 542. Primary power supply locations

1128 IBM TotalStorage DS8000: Service Guide

Page 15: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 270. Primary power supply locations (continued)

Location code FRU name Connector

U2107.mmm.sssssss-Ex-E2 Booster power module

(optional)

U2107.mmm.sssssss-Ex-E3 5/12V DDM power module

(optional)

U2107.mmm.sssssss-Ex-E3 208VDC base module

PFC Module208 VDCBase Module

1yae1z

PPS Front / Fans Removed

Figure 543. Power supply locations (front view with fans removed)

Chapter 42. Location codes 1129

Page 16: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

1130 IBM TotalStorage DS8000: Service Guide

Page 17: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

5/12V DDM power module locations

Table 271. Power supply DDM 5/12V module locations

Location code FRU name Connector

U2107.mmm.ssssss-Ex-Ey

x = 1 (top PPS)

x = 2 (bottom PPS)

y = 1,3

5/12V DDM power module

J1A Bus bar power

J2A Bus bar power

J3A Bus bar power sense

J4A Bus bar power sense

Ex-Ey Bus bar power

AC input power module locations

1xxanf

J1A

J3AID

BdryA +12V

BdryB +12V

BdryB +5V

BdryA +5V

EN

DIS

EN

DIS

J4A

J2A

(J2A)

(J1A)

(Ex-Ey)(J4A)

(J3A)

5/12V DDM Power Module

Figure 544. PPS 5/12V DDM power module locations

Chapter 42. Location codes 1131

Page 18: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 272. Power supply AC input power module

Location code FRU name Connector

1 Primary power supply Mainline power cord connector

2 Primary power supply Mainline CB00

Sequence module locations

AC Input Module

MainlinePower CordConnector

MainlineCB00

1y1fis

Figure 545. PPS AC input power module locations

1132 IBM TotalStorage DS8000: Service Guide

Page 19: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 273. Sequence module locations

Location code FRU name Connector

U2107.mmm.sssssss-Ex Sequence module

U2107.mmm.sssssss-Ex-T1 RPC 1 communication

U2107.mmm.sssssss-Ex-T2 RPC 2 communication

U2107.mmm.sssssss-Ex-T3 PPS to PPS

communication

U2107.mmm.sssssss-Ex-T4 UEPO loop

U2107.mmm.sssssss-Ex-T5 Rack identity card

U2107.mmm.sssssss-Ex-T6 Battery backup unit

interface

U2107.mmm.sssssss-Ex-T7 Battery backup unit

charge

U2107.mmm.sssssss-Ex-T11 Fan sense card

U2107.mmm.sssssss-Ex-T12 Fan sense card

1xxane

S0

S1

S2

EN

EN

EN

DIS

DIS

DIS

(J8-1)

EX-T4

EX-T7

(J8-2)

EX-T9

EX-T10

EX-T6

EX-T11

EX-T12

EX-T3

EX-T5

EX-T2

EX-T1

PPS Sequence Module

J4

J7

J9

J10

J6 J11 J12

J3

J5

J2

J1

Figure 546. PPS sequence module locations

Chapter 42. Location codes 1133

Page 20: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Battery module set rear locations

Table 274. Battery module set rear locations

Location code FRU name Connector

U2107.mmm.sssssss-E1x-E1

x = 0 (top position)

x = 1 (middle position)

x = 2 (bottom position)

Battery module chassis

U2107.mmm.sssssss-E1x-T1 208VDC bus bar

U2107.mmm.sssssss-E1x-T2 208VDC bus bar

U2107.mmm.sssssss-E1x-T3 PPS charging

U2107.mmm.sssssss-E1x-T4 PPS charging

U2107.mmm.sssssss-E1x-T5 PPS control interface

U2107.mmm.sssssss-E1x-T6 PPS control interface

U2107.mmm.sssssss-E1x-E3 Battery module chassis fan

1xxa

yg

LED

CB1

E1X- E3

E1X- E1 X = 0 TOP= 1 Middle= 2 Bottom

CB0

E1X- T5

E1X

-T

4E

1X

-T

3

E1X

-T

1E

1X

-T

2

E1X- T6

Figure 547. Battery module set locations (rear)

1134 IBM TotalStorage DS8000: Service Guide

Page 21: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

DASD fan tray assembly

Table 275. Fan sense card locations

Location code FRU name Connector

U2107.mmm.sssssss-A1 DASD fan tray

assembly

U2107.mmm.sssssss-A1-T4 5/12V power

U2107.mmm.sssssss-A1-T5 5/12V power

U2107.mmm.sssssss-A1-T6 Rear fan sense card

U2107.mmm.sssssss-A2 DASD fan tray

assembly

U2107.mmm.sssssss-A2-T4 5/12V power

U2107.mmm.sssssss-A2-T5 5/12V power

U2107.mmm.sssssss-A2-T6 Rear fan sense card

U2107.mmm.sssssss-A3 DASD fan tray

assembly

U2107.mmm.sssssss-A3-T4 5/12V power

U2107.mmm.sssssss-A3-T5 5/12V power

U2107.mmm.sssssss-A3-T6 Front fan sense card

f2c0

03

14

Fans

Front

1

Figure 548. Identify LED for DASD fan tray

Chapter 42. Location codes 1135

Page 22: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Fan sense card locations

Table 276. Fan sense card locations

Location code FRU name Connector

U2107.mmm.sssssss-Cx

x = 3(front of rack)

x = 4(rear of rack)

Fan sense card

U2107.mmm.sssssss-Cx-T1 Storage enclosure

U2107.mmm.sssssss-Cx-T2 Storage enclosure

U2107.mmm.sssssss-Cx-T3 Storage enclosure

U2107.mmm.sssssss-Cx-T4 Storage enclosure

U2107.mmm.sssssss-Cx-T5 Storage enclosure

U2107.mmm.sssssss-Cx-T6 Storage enclosure

U2107.mmm.sssssss-Cx-T7 Storage enclosure

J1

J2

J3

J4

J5

J6

J7

J8

J9

J10

J11 J12

J13

J14

Cx-T1

Cx-T2

Cx-T3

Cx-T4

Cx-T5

Cx-T6

Cx-T7

Cx-T8

Cx-T9

Cx-T10

Cx-T11 Cx-T12 Cx-T14

Cx-T13

Cx

x=3 Front cardx=4 Rear card

1y1

fip

Figure 549. PPS fan sense card locations

1136 IBM TotalStorage DS8000: Service Guide

Page 23: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 276. Fan sense card locations (continued)

Location code FRU name Connector

U2107.mmm.sssssss-Cx-T8 Storage enclosure

U2107.mmm.sssssss-Cx-T9 DASD fan tray

U2107.mmm.sssssss-Cx-T10 DASD fan tray

U2107.mmm.sssssss-Cx-T11 PPS 1

U2107.mmm.sssssss-Cx-T12 PPS 2

U2107.mmm.sssssss-Cx-T13 Fan sense card to fan sense card

U2107.mmm.sssssss-Cx-T14 Rack identity card

Local remote switch card locations

Table 277. Local remote switch card locations

Location code FRU name Connector

U2107.mmm.sssssss-C6 Local remote switch card

Rack identity card locations

Table 278. Rack identity card locations

Location code FRU name Connector

U2107.mmm.sssssss-C5 RPC card (right from rear

view)

1y1fiz

C6

J5 J6

Figure 550. PPS local remote switch card locations

1xxay6

C5

C5-T

1

C5-T

2

J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12J13

Figure 551. PPS rack identity card locations

Chapter 42. Location codes 1137

Page 24: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 278. Rack identity card locations (continued)

Location code FRU name Connector

U2107.mmm.sssssss-C5-T1 Fan sense card, front

U2107.mmm.sssssss-C5-T2 Fan sense card, rear

1138 IBM TotalStorage DS8000: Service Guide

Page 25: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

RPC card locations

Table 279. RPC card locations

Location code FRU name Connector

U2107.mmm.sssssss-C1 RPC card (right from rear view)

U2107.mmm.sssssss-C2 RPC card (left from rear view)

U2107.mmm.sssssss-Cx-T1 Rack identity card

U2107.mmm.sssssss-Cx-T201 PPS rack 1

U2107.mmm.sssssss-Cx-T202 reserved

U2107.mmm.sssssss-Cx-T203 PPS rack 2

U2107.mmm.sssssss-Cx-T204 Local remote switch card

U2107.mmm.sssssss-Cx-T205 PPS rack 3

U2107.mmm.sssssss-Cx-T206 reserved

U2107.mmm.sssssss-Cx-T207 reserved

U2107.mmm.sssssss-Cx-T208 RPC card to RPC card

U2107.mmm.sssssss-Cx-T209 reserved

U2107.mmm.sssssss-Cx-T210 CEC enclosure 1

1y1fd

s

RPC Rear

RPC2

RPC1

C2-T201 (1)

C2-T1

C1-T1

C1-T201 (1)

C2-T203 (3)

C1-T203 (3)

C2-T205 (5)

C1-T205 (5)

C2-T207 (7)

C1-T207 (7)

C2-T209 (9)

C1-T209 (9)

C2-T211 (11)

C1-T211 (11)

C2-T213 (13)

C1-T213 (13)

C2-T215 (15)

C1-T215 (15)

DIPSwitch

DIPSwitch

Position 6

Position 6

Position 1

Position 1

C1-T204 (4)

C1-T202 (2)

C1-T206 (6)

C1-T208 (8)

C1-T210 (10)

C1-T212 (12)

C1-T214 (14)

C1-T216 (16)

C2-T202 (2)

C2-T204 (4)

C2-T206 (6)

C2-T208 (8)

C2-T210 (10)

C2-T212 (12)

C2-T214 (14)

C2-T216 (16)

Figure 552. PPS RPC card locations

Chapter 42. Location codes 1139

Page 26: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 279. RPC card locations (continued)

Location code FRU name Connector

U2107.mmm.sssssss-Cx-T211 reserved

U2107.mmm.sssssss-Cx-T212 reserved

U2107.mmm.sssssss-Cx-T213 reserved

U2107.mmm.sssssss-Cx-T214 CEC enclosure 2

U2107.mmm.sssssss-Cx-T215 reserved

U2107.mmm.sssssss-Cx-T216 not used

zSeries local remote switch card locations

Table 280. zSeries local remote switch card locations

Location code FRU name Connector

U2107.mmm.sssssss-C6 zSeries local remote

switch card

Storage enclosure location codes

For storage enclosure location codes, see Figure 554 on page 1141 and Figure 555

on page 1141. For storage enclosure part numbers, see “Storage enclosure part

numbers” on page 1096.

Location codes for parts except DDMs

1y1fit

C6 C6-T5C6-T1 C6-T2

C6-T4C6-T3

C6-T6

Local Remote Switch

J1 J2

J4J3

Figure 553. PPS zSeries local remote switch card locations

1140 IBM TotalStorage DS8000: Service Guide

Page 27: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Table 281. Location codes for parts except DDMs

Location code Part name

U2107.D01.sssssss Storage enclosure

U2107.D01.sssssss-P1 Storage enclosure backplane

U2107.D01.sssssss-P1-C1 Fibre channel interface card (FCIC)

U2107.D01.sssssss-P1-C1-Tx (x = 1-4 left to right) (Connector on FCIC)

U2107.D01.sssssss-P1-C2 Fibre channel interface card (FCIC)

U2107.D01.sssssss-P1-C2-Tx (x = 1-4 left to right) (Connector on FCIC)

U2107.D01.sssssss-P1-C2-Dx (x = 1-16) (Connector that leads to DDM)

Location codes for DDMs

Table 282. Location codes for DDMs

Location code Part name

U2107.D01.sssssss-P1-C2-Dx (x = 1-16) Disk drive module

73 GB 15K RPM DDM

146 GB 10K RPM DDM

300 GB 10K RPM DDM

1xxa

y8

P1

P1-C1 P1-C2

P1-C1-T1 P1-C2-T1P1-C1-T2 P1-C2-T2P1-C1-T3 P1-C2-T3

P1-C1-T4 P1-C2-T4

not used not used

Figure 554. Storage enclosure locations

1xxa

y9

P1-D1 P1-D2 P1-D3 P1-D4

P1-D5 P1-D6 P1-D7 P1-D8

P1-D9 P1-D10 P1-D11 P1-D12

P1-D13 P1-D14 P1-D15 P1-D16

P1

Figure 555. Storage enclosure locations (continued)

Chapter 42. Location codes 1141

Page 28: Chapter 42. Location codes - isskk.comChapter 42. Location codes This section contains the system drawings and associated descriptive tables with location code information, including

Management Console location codes

Figure 556 and Table 283 contain location code information for the Management

Console. For part numbers, see “Management Console part numbers” on page

1109.

Table 283. Management Console location codes

Location code FRU name Connector

8676.mmm.sssssss-P1-C1-T1 see note Ethernet

8676.mmm.sssssss-P1-C1-T2 see note Not used

8676.mmm.sssssss-P1-T1 see note Ethernet

8676.mmm.sssssss-P1-T2 see note Ethernet

Note: See X335 Hardware Maintenance Manual and Troubleshooting Guide on the

DS8000 documentation CD from the ship group.

PCI Card 2

Link Status LED Customer Network(P1-T1) ETH-2

DS8000 Network(P1-T2) ETH-3

DS8000 Network(P1-C2-T1) ETH-0

Unused(P1-C2-T2) ETH-1

1tk

0o9

Figure 556. HMC server rear view displaying Ethernet plugs

1142 IBM TotalStorage DS8000: Service Guide