y o u r q u a l i t y p a r t n e r w o r l d w i d e precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette Microdispenser pipettes Low profile dispensers Bottle-top dispensers Laboratory syringes Pipette controllers Pipette tips / consumables Work stations Service center Digital reading micropipettes liquid

Upload: others

Post on 30-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

y o u r q u a l i t y p a r t n e r w o r l d w i d e

precision volumetryElectronic micropipettes

Positive displacement pipettes

Digital setting micropipettes

Repeater pipette

Microdispenser pipettes

Low profile dispensers

Bottle-top dispensers

Laboratory syringes

Pipette controllers

Pipette tips / consumables

Work stations

Service center

Digital reading micropipettes

liquid

Page 2: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

Dear Partner in science,

You are holding the new Socorex 2013-2014 catalogue edition, marking our company’s 50 th anniversary! It features a number of novelties you will enjoy discovering and using in your liquid dosing applications.

A major step ahead in our product line is, without a doubt, the addition of the exceptional Calibrex™ organo and solutae bottle-top dispensers. Made of sturdy materials, well thought out in terms of innovative functions and metrological performance, the new Calibrex™ line has rapidly and successfully proven itself in the hands of demanding scientists.

The new revolving Twister™ pipette stand also quickly met a great success. Distinct from any carousel unit available in the market so far, it fits all micropipette brands owed to its universal concept, while bringing a selection of bright colours to the lab bench.

Significant progress has been made with our long established international partner network, adding new forces where needed. Their details are listed in the Distributor section of our web site. Highly qualified, well documented and equipped to provide the best advice and technical support, they work hand in hand with the thousands of end-users trusting Socorex throughout the world.

I seize the opportunity to pay a special tribute to both communities for their loyalty and contribution to our successful growth over so many years.

Sincerely

Sylvain Christen, CEO

Products & services

Today’s manufacturing programme includes a wide variety of high precision instruments used for reliablymeasuring, dosing, transferring, dispensing and injecting liquids in a large number of applications.

Manual and electronic micropipettes, single and multichannel pipettors, repeater pipettes, dispensers, pipette controllers and re-usable syringes, together with their accessories, constitute the heart of the programme.

Each precision instrument bears its own serial number and passes a strict performance control attested by an individual QC certificate.

The Socorex Service Center offers a global repair and calibration programme. The choices range from basic maintenance to accredited calibrations of all micropipettes and dispensers according to ISO 17025 – whatever their brand.

Welcome to Socorex – a world of expertise in prec

Sylvain Christen, CEO

Laurence Louy-Drevici, Business Development

Jean-Pierre Uldry, Director of Engineering

Aurelie Stangoni, Customer Service

Beatriz Grasset, Sales Administration Manager

Prisca Buchs,Customer Service

Tatjana Van Bogaert, CEO Assistant

Pascal Durand, Admin. and Finance Manager

Thérèse Valenziano, Customer Service

Brief history

Socorex Isba SA, often referred to as just Socorex per its original name, was first founded in the late 1940s. Two young watchmakers had identified the need for new types of quality syringes for medical applications. The products rapidly met international success. In search of synergies, the company subsequently merged with another firm, moved to the city of Lausanne on Lake Geneva, changed name to become Socorex Isba SA and finally, under a new family ownership, built up-to-date premises in Ecublens – we are in 1963. Fifty years later, still with the same shareholders, Socorex has grown its two distinct laboratory and animal health divisions, reflecting a long time strategic reconversion. An important 50 th anniversary year, 2013 marked the inauguration of a major facility improvement programme. This included the construction of a new administration building and production plant expansion. Enlarged, the modern site will support the company’s capacity to handle many more success stories in the future.

Page 3: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

Our customers

We are proud to include virtuallyall private, industrial, academicand government laboratories asour customers.

Those are involved in routine research and educational activities in fields as diverse as lifesciences – such as biotechnology and molecular biology – medicine, chemistry, pharmacology, environment, agriculture, etc.

Scientists are served efficiently by the dedicated network of Socorex distributors. Selected amongst the best suppliers, they carry an inventory of our products and provide technical support, repair and calibration services.

Find your closest Socorex partners listed on www.socorex.com

Quality achievements

Socorex’s dedication to precision and quality has been an all-time tradition. Our commitment to manufacturing the most reliable instruments and offering the best services was formalised with the completion of the ISO 9001 and ISO 13485 Quality Management System certifications.

Product lines used in the In Vitro Diagnostics fields conform tothe IVD 98/79 EEC directive for medical devices and are CEcertified accordingly.

Instruments are designed to operate under national and international standards such as ISO 8655, GLP, GMP and NCCLS.

Warranty coverage is three years on all manual pipettors, two years on electronic pipettes, dispensers and repeaters.

Product range

Electronic micropipettes

Acura® electro

Digital reading micropipettes

Acura® manual and Acura® manual XS

Digital setting micropipettes

Calibra® digital

Positive displacement pipettes

Acura® positive

Repeater pipette

StepperTM / EcostepTM

Microdispenser pipettes

Acura® manual

Bottle-top dispensers

CalibrexTM digital

Low-profile dispensers

AcurexTMcompact

Laboratory syringes

DosysTM

Pipette tips / consumables

Qualitips®

Pipette controllers

ProfillerTM / ProfilletteTM

Work stations

Service center

3

7

14

16

17

18

19

20

26

31

30

37

39Yves Liechti,Logistics Manager

Jean-Marc Ammann, Qualityand Regulatory Affairs Manager

Jean-Pierre Cattin, Production Manager

Stephanie Boegli,Service Center

Christele Donze,Customer Service

Pascal Forestier, Technical Support Manager

Susanne Henry, Communication Project Manager

Yves Lachavanne, Marketing and Sales Support Manager

ision liquid handling

Page 4: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

The Acura® electro models

926XS micro, 936 macro, 956 multi

Product advantages

Optimal ergonomics, light weightEasy, intuitive, self-teaching programmeLarge display, reversible for right or left readingSwift-interchange battery packFast charge, long working autonomyAdjustable tip ejector* fitting most tipsPipetting cycle counter27 interchangeable volumetric modules

all fitting same control unit * Socorex patented

Natural ergonomicsThe Acura® electro offers shape, balance and working ergonomics resembling those of a manual instrument. But comfort is so greatly improved that pipetting and result consistency are just outstanding.

Unique “right or left”

display readingDisplay converts instantly to right or left side reading. All information clearly presented and visible at a glance during programming, pipetting and calibration steps.

Variable working speedLocated on the front side, speed selector allows swift change even during the pipetting process. In addition, slow speed access at any time by gentle touch of start button.

Pipetting cycle counter A simple double click gives access to the number of pipetting cycles performed since last zeroing.

Tip ejection – easier than everMaximal efficiency obtained with a large surface, ergonomically located ejector button. The shaft height adjustment system called JustipTM (4 mm span) - controlled by efficient click-stops - allows a wide selection of tips to tightly fit the nozzle.

The multichannel bowed shape ejector head permits effortless, sequential tip ejection.

Latest up-grade of a successful line making electronic pipetting simpler and safer than ever. The microprocessor-controlled instrument includes intuitive software avoiding any complicated programming steps. No particular skills are required to get quick access to six working modes and many volumes to select from. Two-year warranty.

3

2 3 4 51

1

2

3 5

4

electronic micropipettesAcura®electro

Page 5: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

Long working autonomy NiMH battery pack exchangeable instantly. Fast battery charging (< 1.5 hours) and extended working autonomy (> 3000 consecutive pipetting cycles). Battery charge level clearly visible on display. Automatic energy saving stand-by when unused.

Interchangeable

volumetric modules One control unit fits a choice of 27 volumetric assemblies available separately. This greatly extends working possibilities and makes electronic pipetting affordable to all budgets. Disassembling and re-assembling without any tool contributes towards maximal flexibility.Calibration specificities of extra modules - as set by factory QC or by pipette owner - are retained in instrument memory.

Great built-in working flexibilitySurf through mode selection by pressing a single button.

Forward mode

Aspiration and pipetting of set volume. Suitable for all applications.

Reverse mode

Aspiration in excess, followed by dosing of set volume. Enhances reproducibility below 20 μL. Especially recommended for viscous and foaming liquids.

Stepper mode

Tip filling and step-by-step distribution. Best suited to aliquot samples.

Dilution mode

Aspiration of 2 or 3 different volumes for restitution in one shot. An easy way to dilute samples.

Tactile mode

“Start and stop” liquid measurement, titration and gel loading by simple touch of activation button.

Mixing

“Up and down” liquid flow in the tip / vial.

Pipette charging stand Stand allows charging and storing up to three electronic pipettes or battery packs simultaneously. Each position is fitted with a red/green charging LED. One stand supplied with every initial package.

Battery charging rack Space saving stand holds up to three battery packs simultaneously. The ideal charging and storage accessory for spare batteries, available at any time.

CalibrationControl software gives immediate access to calibration menu. Performance check possible over two or three independent volumes (Vmin, Vmid and Vmax). New settings entered directly from the keyboard.Error message warns of any inaccurate plunger movement.

4

www.socorex.com

4

4

3

3

5

5

ENERGY STAR®

qualified powersupply for a betterenvironment

2

1

1 2

Page 6: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

5

Nozzle protection filter Macro models accommodate a filter protecting instrument against liquid overflow and contamination. Located in the nozzle, it can be removed and changed easily.

Pasteur pipette -

straw tip adapters Optional accessories fit 2 mL glass Pasteur pipettes or 5 mL straw tip instead of Polypropylene tips.

Optimal working position 360° rotation of multichannel volumetric modules allows selection of the best working position.

Time efficient maintenancePipette construction limits maintenance to a minimum - no tool required to remove volumetric module. The pipetting cycle counter facilitates maintenance monitoring.

Whenever sterilisation is needed, volumetric modules can be autoclaved at 121°C / 250°F.

Initial package Recommended when purchasing an Acura® electro for the first time, each initial package contains one electronic pipette, QC certificate and operating instructions, charging stand, power supply, additional battery pack, Qualitips® pipette tips samples. Thereafter, additional pipettes can be purchased alone and charged on existing stand.

2 3 41

1

2

3 5

4

5

926XSmicro

0.1 - 2 μL0.5 – 10 μL

1 - 20 μL2.5 - 50 μL5 - 100 μL

10 - 200 μL50 - 1000 μL

936macro

0.1 - 2 mL0.25 - 5 mL0.5 - 10 mL

956multi

0.5 - 10 μL2.5 - 50 μL10 - 200 μL20 - 350 μL

The Acura® electro product advantages

Micropipettes

Reduced shaft length and conical end improve driveability

Easy access to microtubes and microplatesOptional longer volumetric modulesSimple conversion by user at any timeUnsurpassed metrological performance

and stability

Macropipettes

Interchangeable nozzle protection filterAdapters for Pasteur pipette and straw tipsOutstanding accuracy and precision

Multichannel

Large selection of 8- and 12-channel modelsLight weight and perfect hand fittingSequential tip ejectionAlso fit any single channel volumetric module

electronic micro- macro and multichannel pipettesAcura®electro

Page 7: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

www.socorex.com

0.1 – 2 μL0.5 - 10 μL0.5 - 10 μL1 - 20 μL2.5 - 50 μL5 - 100 μL10 - 200 μL50 - 1000 μL

0.1 - 2 mL0.25 - 5 mL0.5 - 10 mL

0.5 - 10 μL2.5 - 50 μL10 - 200 μL20 - 350 μL

0.5 - 10 μL2.5 - 50 μL10 - 200 μL20 - 350 μL

0.01 μL0.05 μL0.05 μL0.1 μL0.25 μL0.5 μL1.0 μL5.0 μL

0.01 mL0.05 mL0.05 mL

0.05 μL0.25μL1.0 μL5.0 μL

0.05 μL0.25 μL1.0 μL5.0 μL

<+/- 2.5 % 1)

<+/- 1.2 % 2)

<+/- 1.2 % 2)

<+/- 1.2 % 2)

<+/- 1.0 % 2)

<+/- 1.0 % 2)

<+/- 1.0 % 2)

<+/- 0.8 % 2)

<+/- 1.5 % 2)

<+/- 1.2 % 2)

<+/- 1.0 % 2)

<+/- 3.5 % 2)

<+/- 1.0 % 2)

<+/- 0.9 % 2)

<+/- 1.0 % 2)

<+/- 3.5 % 2)

<+/- 1.0 % 2)

<+/- 0.9 % 2)

<+/- 1.0 % 2)

<+/- 0.9 %<+/- 0.6 %<+/- 0.6 %<+/- 0.5 %<+/- 0.5 %<+/- 0.5 %<+/- 0.4 %<+/- 0.4 %

<+/- 0.5 %<+/- 0.5 %<+/- 0.5 %

<+/- 1.0 %<+/- 0.8 %<+/- 0.6 %<+/- 0.6 %

<+/- 1.0 %<+/- 0.8 %<+/- 0.6 %<+/- 0.6 %

<+/- 1.2 %<+/- 0.8 %<+/- 0.8 %<+/- 0.6 %<+/- 0.6 %<+/- 0.6 %<+/- 0.6 %<+/- 0.5 %

<+/- 1.0 %<+/- 0.8 %<+/- 0.7 %

<+/- 1.5 %<+/- 0.9 %<+/- 0.7 %<+/- 0.8 %

<+/- 1.5 %<+/- 0.9 %<+/- 0.7 %<+/- 0.8 %

Performance values obtained in Forward mode with bi-dist. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655. Performance measured at: 1) 0.5 μL, 2) 10% of nominal volume

* Replace E by country code if other plug type than Europe style needed: G = UK, U = USA-Japan, A = Australia-NZ

< 2.5 % 1)

< 1.5 % 2)

< 1.7 % 2)

< 1.2 % 2)

< 0.7 % 2)

< 0.7 % 2)

< 0.6 % 2)

< 0.4 % 2)

< 0.6 % 2)

< 0.6 % 2)

< 0.5 % 2)

< 3.0 % 2)

< 1.0 % 2)

< 0.6 % 2)

< 0.6 % 2)

< 3.0 % 2)

< 1.0 % 2)

< 0.6 % 2)

< 0.6 % 2)

Ultra 10 μLUltra 10 μL

200 μL200 μL200 μL200 μL200 μL1000 μL

2 mL5 mL10 mL

Ultra 10 μL200 μL200 μL350 μL

Ultra 10 μL200 μL200 μL350 μL

926.0002E926.0010E926.0010YE926.0020E926.0050E926.0100E926.0200E926.1000E

936.02E936.05E936.10E

956.08.010E956.08.050E956.08.200E956.08.350E

956.12.010E956.12.050E956.12.200E956.12.350E

926.0002926.0010926.0010Y926.0020926.0050926.0100926.0200926.1000

936.02936.05936.10

956.08.010956.08.050956.08.200956.08.350

956.12.010956.12.050956.12.200956.12.350

< 0.8 %< 0.35 %< 0.4 %< 0.3 %< 0.25 %< 0.2 %< 0.15 %< 0.1 %

< 0.15 %< 0.15 %< 0.15 %

< 0.7 %< 0.4 %< 0.25 %< 0.25 %

< 0.7 %< 0.4 %< 0.25 %< 0.25 %

< 1.5 %< 0.7 %< 0.8 %< 0.4 %< 0.3 %< 0.3 %< 0.2 %< 0.15 %

< 0.3 %< 0.3 %< 0.2 %

< 0.9 %< 0.6 %< 0.4 %< 0.4 %

< 0.9 %< 0.6 %< 0.4 %< 0.4 %

Volume Division Tip style Cat. No.Initial

package*

Cat. No. Pipette alone

Mid. vol. Max. volMin. vol.Inaccuracy (E%)

Mid. vol.Min. vol.Imprecision (CV%)

Max. vol

Micropipettes Acura® electro 926XS

12-channel pipettes Acura® electro 956

8-channel pipettes Acura® electro 956

Macropipettes Acura® electro 936

6

Ordering information - Volumetric modules and accessories

Performance and ordering information – InstrumentsInitial package includes pipette, charging stand and accessories. Additional pipettes (alone) supplied with individual QC certificate, Qualitips® pipette tips samples and operating instructions.

1.835.6311.835.633

1.831.707

Adapter - 5 mL straw tip

800.12.010800.12.050800.12.200800.12.350

800.0002800.0010800.0010Y800.0020800.0050800.0100800.0200800.1000

Volume range Tip style Cat. No.

0.1 - 2 μL0.5 - 10 μL0.5 - 10 μL1 - 20 μL2.5 - 50 μL5 - 100 μL10 - 200 μL50 - 1000 μL

Ultra 10 μLUltra 10 μL

200 μL200 μL200 μL200 μL200 μL1000 μL

800.0002XS800.0010XS800.0010YXS800.0020XS800.0050XS800.0100XS800.0200XS800.1000XS

Single channel microvolumes

Reduced shaft length

0.1 - 2 μL0.5 - 10 μL0.5 - 10 μL1 - 20 μL2.5 - 50 μL5 - 100 μL10 - 200 μL50 - 1000 μL

Ultra 10 μLUltra 10 μL

200 μL200 μL200 μL200 μL200 μL1000 μL

Regular shaft length

800.08.010800.08.050800.08.200800.08.350

Volume range Tip style Cat. No.

0.1 - 2 mL0.25 - 5 mL0.5 - 10 mL

2 mL5 mL10 mL

800.2000800.5000800.10000

Single channel macrovolumes

Description Pack Cat. No.

Stand for pipettes or battery packsStand for power handles only

1 / pk1 / pk

320.903.48320.913.48

NiMH, 4.8VNiMH, 4.8V

1 / pk2 / pk

900.920.48900.922.48

Spare battery, blue colour

For 2 and 5 mL modelsFor 10 mL model

250/pk100/pk

322.05322.10

Nozzle protection filters

Europe style plugUK style plugUSA-Japan style plugAustralia - NZ style plug

1 / pk1 / pk1 / pk1 / pk

900.901.48E900.901.48G900.901.48U900.901.48A

Power supply, 100-240V0.5 - 10 μL2.5 - 50 μL10 - 200 μL20 - 350 μL

Ultra 10 μL200 μL200 μL350 μL

8-channel microvolumes

0.5 - 10 μL2.5 - 50 μL10 - 200 μL20 - 350 μL

Ultra 10 μL200 μL200 μL350 μL

12-channel microvolumes

Charging units, 3 positions

For 2 mL modelFor 5 mL model

1 / pk1 / pk

Adapter-nozzle - Pasteur pipette

For 2 and 5 mL models 1 / pkSee Qualitips® page 32 - 34

3

3

3

4

45

52

2

1

1

electronic pipettes & accessoriesAcura®electro

Page 8: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

Mid. vol.Volume

Mid. vol. Max. vol. Min. vol.Tip style

Min. vol. Max. vol.Division

< 1.5%< 0.5%< 0.7%< 0.5%< 0.4%< 0.2%< 0.2%< 0.2%

< 3.3%< 1.2%< 1.6%< 1.1%< 0.7%< 0.6%< 0.4%< 0.4%

< 5.0%1)

< 1.8%2)

< 2.5%< 1.7%< 1.0%< 1.0%< 0.6%< 0.5%

< 2.0%< 1.0%< 1.0%< 1.0%< 1.0%< 0.8%< 0.6%< 0.5%

< ± 6.0%1)

< ± 2.5%2)

< ± 2.5%< ± 2.5%< ± 1.5%< ± 1.5%< ± 1.5%< ± 1.5%

< ± 4.0%< ± 1.8%< ± 1.8%< ± 1.8%< ± 1.3%< ± 1.2%< ± 1.1%< ± 1.0%

0.1 – 2 μL 0.5 – 10 μL1 – 10 μL 2 – 20 μL5 – 50 μL10 – 100 μL20 – 200 μL100 – 1000 μL

Ultra 10 μLUltra 10 μL

200 μL200 μL200 μL200 μL200 μL1000 μL

0.002 μL0.01 μL0.01 μL0.02 μL0.1 μL0.1 μL0.2 μL1 μL

Inaccuracy (E%) Imprecision (CV%)

Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655. 1) measured at 0.5 μL 2) measured at 1 μL

The Acura® manual 825 / 826 XS

Product advantages

Smart and reliable volume adjustmentSingle-handed volume settingPrecision digital display visible at all timeJustipTM adjustable tip ejector* fitting most tipsSwift-set user calibration system*Shock, UV-light and autoclaving resistanceCE certified IVD 98/79 EEC

* Socorex patented

Most comfortable pipettingThe Acura® manual fits everybody’s hand with or without glove. Ergonomic shape, light weight and soft plunger travel care for better comfort.

Ejector button Ergonomically positioned, the large surface, soft padded ejector provides for low-pressure activation.

Adjustable tip ejection Ejector shaft height adjustment system called JustipTM allows a wide selection of tips to tightly fit the nozzle.

Minimum maintenance /

sterilisation Easy disassembling for thorough cleaning. Sterilisation achieved by autoclaving instrument fully assembled (121°C / 250°F).

The Acura® manual are precision pipettes combining high-tech materials with exceptional, user friendly ergonomics. There is a choice between 825 model, the classic one for all applications and 826 XS micropipette specially dedicated to research. Both lines bring much more than superior performance and makepipetting safe and agreeable. Three-year warranty.

7

Performance and tip style - Acura® manual 825 and 826 XS micropipettes

5

5

2

2

3

3 4

41

1

825micro

0.1 – 2 μL0.5 – 10 μL1 – 10 μL2 – 20 μL5 – 50 μL10 – 100 μL20 – 200 μL100 – 1000 μL

digital reading micropipettesAcura®manual and Acura®manual XS

Page 9: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

8

www.socorex.com

Instant calibrationSwift-set user calibration system - with integrated key and locking mechanism - makes tedious procedures a thing of the past. Easy and precise, it is in full compliance with international standards and recommendations.

Safety seal Though easily removed when needed, the switch protection seal is autoclaving resistant. Extra smooth activation

Unique tightness lip seal and new springs provide for ultra-soft pipetting, reducing hand fatigue while working.Above forces, measured on a 20 - 200 μL model, are indicative of very limited finger efforts. Yet, the overshoot stop offers a clear tactile indicator.

* 1 Newton (N) ~ 0.1 kilogramme force (kgf)0.1 - 2 μL0.5 - 10 μL1 - 10 μL2 - 20 μL5 - 50 μL10 - 100 μL20 - 200 μL100 - 1000 μL

Volume weight Cat. No.

88 gr88 gr88 gr88 gr90 gr92 gr90 gr95 gr

84 gr84 gr85 gr85 gr86 gr87 gr86 gr88 gr

825.0002825.0010825.0010Y825.0020825.0050825.0100825.0200825.1000

826.0002826.0010826.0010Y826.0020826.0050826.0100826.0200826.1000

825 826 XS 825 826 XS

Calibration seal stickers

25 / pk100 / pk

1.825.0251.825.100

Replacement sealsReplacement seals

Weights and ordering information - Acura® manual 825 and 826 XS

1 2

1 2 3

3

826 XSextra sharp

0.1 – 2 μL0.5 – 10 μL

1 – 10 μL2 – 20 μL5 – 50 μL

10 – 100 μL20 – 200 μL

100 – 1000 μL

extrasharp

The Acura® manual 826 XS

Added advantages, distinct from 825 line

Excellent ergonomic shape and size ratioNew springs and tightness seal for extra-smooth activationReduced weight - lighter than leading brands

(see weight chart below)Increased driveability with short, narrow shaftConical shaft end for easy reach in smaller microtubes

Derived from the Acura® manual 825, the 826 XS line was designed with the research scientists in mind. Shorter, smoother, lighter in weight, the eight models offer key features aiming at excellence in pipetting.

Short shaft enhances precision of hand movement and guarantees superior driveability. A great help in fine applications such as pipetting in microtubes or microplates.

See Qualitips® page 32 - 34

Page 10: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

9

The Acura® manual 825 / 835 Triopack

Three adjustable micropipettesLarge choice of volume combinations up to 10 mLNine different packs

Pack Cat. No.Contents (Micro /macropipette models)

Pack Cat. No.Contents (Micro /macropipette models)

Pack Cat. No.Contents (Micro /macropipette models)

825.TRIO.C

825.TRIO.J

825.TRIO.M

C

J

M

2 μL(0.1 – 2)

2 μL (0.1 – 2)10Y μL(1 – 10)

10 μL(0.5 – 10)

20 μL(2 – 20)50 μL

(5 – 50)

50 μL(5 – 50)200 μL

(20 – 200)200 μL

(20 – 200)

825.TRIO.O

825.TRIO.P

825.TRIO.S

O

P

S

10 μL(0.5 – 10)10Y μL (1 – 10)20 μL

(2 – 20)

100 μL(10 – 100)

100 μL(10 – 100)200 μL

(20 – 200)

1000 μL(100 – 1000)

1000 μL(100 – 1000)

1000 μL(100 – 1000)

825.TRIO.T

825.TRIO.V

835.TRIO.Y

T

V

Y

50 μL(5 – 50)100 μL (10 – 100)1000 μL(100 – 1000)

200 μL(20 – 200)1000 μL

(100 – 1000)5 mL

(0.5 – 5)

1000 μL(100 – 1000)

5 mL(0.5– 5)10 mL(1 – 10)

Ordering information - TriopackIncluding: sampling of Qualitips®, silicone grease, Q.C. certificates and operating instructions

The Acura® manual 826 TwiXS pack

Two adjustable volume pipettesFree shelf pipette holder (see page 37)Volume combinations up to 1000 μLSix different packs

All Acura® pipettes have colour-coded button caps for individual, lab or department identifications. Pick among 14 colours or choose the smartie mix for other colour combinations.

Pack

EGHKNQ

2 μL (0.1 - 2)10 μL (0.5 - 10)20 μL (2 - 20)50 μL (5 - 50)

100 μL (10 - 100)200 μL (20 - 200)

20 μL (2 - 20)100 μL (10 - 100)200 μL (20 - 200)200 μL (20 - 200)

1000 μL (100 - 1000)1000 μL (100 - 1000)

Cat. No.Contents (micropipettes)

826.TWX.E826.TWX.G826.TWX.H826.TWX.K826.TWX.N826.TWX.Q

Cat. No.ColourCat. No.Colour

WhiteGreyVanillaLemonYellowOrangeRed

1.825.7101.825.7151.825.7161.825.7121.825.7171.825.7181.825.714

Assorted colours (14 / pk)

Alternative colour selection (6 / pk)

RosePinkPurpleIce blueBlueMintGreen

1.825.7191.825.7201.825.7211.825.7221.825.7131.825.7231.825.711

1.825.700

Ordering information - TwiXS packIncluding: shelf pipette holder, sampling of Qualitips®, silicone grease, Q.C. certificates and operating instructions

Smartie caps

Colour coding at will

Pipette packs offer an extended choice of volume combinations, covering all individual requirements in any research or routine application. Available at attractive saver prices, they match with today’s budget constraints.

micropipette saver packs and smartiesAcura®manual

Page 11: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

Display always visible Located on the front of the instrument, the display window allows set volume to be visible at all times during pipetting. A comforting reassurance for the user.

10

www.socorex.com

Smart and reliable

volume adjustment State-of-the-art micrometric volume setting is performed smoothly and precisely by turning push button. Finely machined click-stops and free rotating cap prevent any unwanted volume alteration.

Mid. vol.Volume

Mid. vol. Max. vol. Min. vol.Tip style Cat. No.

Min. vol. Max. vol.Division

< 0.2%

< 0.3%

< 0.2%

< 0.3%

< 0.5%

< 0.3%

< 0.5%

< 0.6%

< 0.5%

< ± 0.5%

< ± 0.6%

< ± 0.5%

< ± 1.5%

< ± 1.5%

< ± 1.5%

< ± 1.0%

< ± 1.1%

< ± 0.7%

0.2 – 2 mL

0.5 – 5 mL

1 – 10 mL

835.02835.02PP 1)

835.05835.05PP 1)

835.10

2 mL2 mL + Pasteur

5 mL5 mL + Pasteur

10 mL

0.002 mL

0.01 mL

0.01 mL

Inaccuracy (E%) Imprecision (CV%)

Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655. 1) Model includes Pasteur adapter nozzle.

Patented tip ejection system Ergonomically positioned, the large surface, soft padded ejector provides for low-pressure activation. In addition, the shaft height adjustment system called JustipTM allows optimal distance setting between ejector and tip.

Pasteur pipette adapter Adapter nozzles allow fitting of Pasteur pipette on Acura® manual 2 and 5 mL models in addition to polypropylene tips. The adapters have two O-rings guaranteeing proper holding and tightness of standard 2 mL Pasteur pipettes (Ø 7 mm).

Nozzle

protection

filter Protection against liquid overflow and contamination.

Performance and ordering information

The Acura® manual 835

Product advantages

Smart and reliable volume adjustmentSingle-handed volume settingInterchangeable nozzle protection filterJustipTM adjustable tip ejector* fitting most tipsSwift-set user calibration system*Shock, UV-light and autoclaving resistancePasteur pipette fitting 2 and 5 mL models

* Socorex patented

835macro

0.2 – 2 mL0.5 – 5 mL1 – 10 mL

See consumables page 35 - 36

5 6

6

1

2

Instruments combining high-tech materials with user-friendly ergonomics. Optimal for in- and outdoor environmental analysis, clinical chemistry and cell culture applications, they offer superior performance and make pipetting safer than ever. Three-year warranty.

3

3 54

41 2

digital reading macropipettesAcura®manual

Page 12: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

The Acura® manual 815 / 835F

Product advantages

Slim ergonomic design and light weightSoft plunger activationJustipTM adjustable tip ejector* fitting most tipsUser calibration with integrated keyColour coded smartie capSelection includes macropipette volumes

* Socorex patented

Cat. No.Inaccuracy (E%)

Imprecision (CV%)

Tip styleVolume

1 μL5 μL10 μL10Y μL15 μL20 μL25 μL30 μL32 μL40 μL50 μL60 μL70 μL75 μL80 μL90 μL100 μL120 μL

Acura® manual 815

< ± 2.0%< ± 1.4%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.75%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%

< 1.0%< 1.0%< 0.7%< 0.8%< 0.5%< 0.5%< 0.6%< 0.6%< 0.6%< 0.5%< 0.4%< 0.5%< 0.4%< 0.4%< 0.35%< 0.3%< 0.3%< 0.4%

Ultra 10 μLUltra 10 μLUltra 10 μL

200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL

815.0001815.0005815.0010815.0010Y815.0015815.0020815.0025815.0030815.0032815.0040815.0050815.0060815.0070815.0075815.0080815.0090815.0100815.0120

Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°Cin accordance with ISO 8655.

Cat. No.Inaccuracy (E%)

Imprecision (CV%)

Tip styleVolume

150 μL200 μL250 μL300 μL400 μL500 μL600 μL700 μL750 μL800 μL900 μL1000 μL

2 mL2.5 mL5 mL10 mL

Acura® manual 835F

Acura® manual 815 (Continued)

< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.6%

< ± 0.8%< ± 0.8%< ± 0.7%< ± 0.5%

< 0.3%< 0.3%< 0.4%< 0.4%< 0.3%< 0.3%< 0.3%< 0.2%< 0.2%< 0.2%< 0.2%< 0.2%

< 0.5%< 0.5%< 0.3%< 0.2%

200 μL200 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL

2 mL5 mL5 mL10 mL

815.0150815.0200815.0250815.0300815.0400815.0500815.0600815.0700815.0750815.0800815.0900815.1000

835.F02835.F02.5835.F05835.F10

Performance and ordering information

Tip ejection – easier than everMost ergonomically positioned, the large surface, soft padded ejector button provides for low-pressure activation. In addition to ease of tip ejection, the shaft height adjustment system called JustipTM – controlled by efficient click-stops – allows a wide selection of tips to tightly fit the nozzle.

815 / 835Ffixed

1 μL to 10 mL

11

See Qualitips® page 32 - 34

1 2 3

21

Fixed volume micro and macropipettes show the most stable performance. They provide consistent results for any analytical or routine diagnostic tests by eliminating the risk of erroneous volume setting. Three-year warranty.

3

fixed volume pipettesAcura®manual

Page 13: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

www.socorex.com

12

Built with the users in mind, these pipettes combine high-tech materials with exceptional, user-friendly ergonomics. They extend pipetting possibilities in 96-well microplates and guarantee outstanding performance and results. Three-year warranty.

The Acura® manual 855

Product advantages

8- and 12-channel models up to 350 μLLight weight and perfect hand fittingPrecision digital display visible at all timeJustipTM adjustable tip ejector* fitting most tipsSwift-set user calibration system*360° rotation of volumetric module

* Socorex patented

855 models Weight8x 0.5 - 10 μL8x 5 - 50 μL8x 20 - 200 μL8x 40 - 350 μL12x 0.5 - 10 μL12x 5 - 50 μL12x 20 - 200 μL12x 40 - 350 μL

155 gr165 gr165 gr168 gr184 gr199 gr201 gr203 gr 2 31

855multi

0.5 – 10 μL5 – 50 μL20 – 200 μL40 – 350 μL

Most comfortable pipetting Ergonomic shape, lightweight and ultra-soft plunger travel are key elements of the Acura® manual pipettes.

Optimal working position Revolving over 360°, the volumetric module (lower assembly) helps reaching the appropriate hand position.

Adjustable tip ejector Position of tip ejector can be adjusted in no time within a 4 mm span to perfectly match with tips used. Bowed shape of ejector head guarantees effort-less, easy sequential tip removal.

Multichannel reservoirs Well adapted for multichannel pipettes, the reagent reservoirs offer various shapes and volumes.

1 2 3

See consumables page 35 - 36

Mid. vol.Volume

Mid. vol. Max. vol. Min. vol.Tip style Cat. No.

Min. vol.

Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.1) measured at 1 μL

Max. vol.Division

0.5 – 10 μL5 – 50 μL20 – 200 μL40 – 350 μL

0.5 – 10 μL5 – 50 μL20 – 200 μL40 – 350 μL

0.01 μL0.1 μL0.2 μL0.4 μL

0.01 μL0.1 μL0.2 μL0.4 μL

< ± 3.5%1)

< ± 1.0%< ± 0.9%< ± 1.0%

< ± 3.5%1)

< ± 1.0%< ± 0.9%< ± 1.0%

< ± 2.5%< ± 0.9%< ± 0.8%< ± 0.9%

< ± 2.5%< ± 0.9%< ± 0.8%< ± 0.9%

< ± 1.5% < ± 0.8%< ± 0.7%< ± 0.8%

< ± 1.5%< ± 0.8%< ± 0.7%< ± 0.8%

< 3.0%1)

< 1.0%< 0.6%< 0.6%

< 3.0%1)

< 1.0%< 0.6%< 0.6%

< 1.0%< 0.4%< 0.3%< 0.3%

< 1.0%< 0.4%< 0.3%< 0.3%

< 2.0%< 0.7%< 0.5%< 0.5%

< 2.0%< 0.7%< 0.5%< 0.5%

Ultra 10 μL200 μL200 μL350 μL

Ultra 10 μL200 μL200 μL350 μL

855.08.010855.08.050855.08.200855.08.350

855.12.010855.12.050855.12.200855.12.350

Inaccuracy (E%) Imprecision (CV%)

8-channel

12-channel

Performance and ordering information

multichannel micropipettesAcura®manual

Page 14: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

The Acura® manual 810

Product advantages

Two pre-calibrated fixed volumes – no setting requiredSmooth activation, excellent ergonomics Interchangeable PE nozzle protection filter JustipTM system for height adjustment of tip ejectorIndependent calibration for each volumeEasy maintenance, cleaning and disinfectionFully autoclavable 121°C / 250°F

Air displacement pipette with two pre-calibrated steps allowssubsequent pipetting of 1 and 0.1 mL of the same liquid. Metal nozzle fits long straw tips to aspirate from narrow or deep reservoirs (i.e. Stomacher® bags). Ideal alternative to the graduated glass pipettes when performing serial 1:10 dilutions in bacteriology. Three-year warranty.

Simple operation Depress plunger button in full, then release slowly to aspirate 1.1 mL Depress plunger button to first stop, thus dispensing 1 mL in Petri dish Depress plunger button to second stop, thus dispensing residual 0.1 mL in next Petri dish

No setting requiredTwo fixed volumes within one plunger travel.

Innovative dual calibrationBoth volumes of 1 mL and 0.1 mL can be calibrated independentlyfrom each other. Calibration switch protected by seal sticker.

Volume Inaccuracy(E%)

Imprecision(CV%)

Cat. No.

810.1100< ± 0.5%< ± 2.0%

< 0.4%< 2.5%

1 mL0.1 mL

Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.

Performance and ordering

information – InstrumentDescription

Straw tips, polypropylene, sterilized (L: 190 mm, Ø:4 mm)

Packaging

40x 25 / pk

Cat. No.

313.1119.40Nozzle protection filter, PE materialWork station 340 for 3 pipettesShelf pipette holder 332 for 2 pipettesShelf pipette holder 332 for 2 pipettes

100 / pk 322.8101 / pk 320.3401 / pk4 / pk

320.332320.332.4

Ordering information – Accessories

JustipTM ejectorTurn left or right to adjust ejector to straw tip position on the nozzle.

Straw tipsFirst class polypropylene. Size 190 mm. Specially designed for narrow vials and Stomacher® bags. Large diameter (4mm) prevents blocking by particles in suspension.

8101 + 0.1 mL

1

2

3

1.1 mL 1.0 mL 0.1 mL

1 2 3

13

2 3 41

1

2

3

4

1:10 dilution pipetteAcura®manual

Page 15: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

14

The Calibra® digital 822 / 832

Product advantages

Winding-free, instant volume adjustmentLong term performance and calibration stabilityRobust, long lasting constructionShock, UV-light and autoclaving resistanceReliable user calibrationMinimal maintenance requirementsCE certified IVD 98/79 EECInterchangeable nozzle filter in all macro models

Mid. vol.Volume

Mid. vol. Max. vol. Min. vol.Tip style Cat. No.

Min. vol.Inaccuracy (E%) Imprecision (CV%)

Max. vol.Division

< 1.5%< 0.5%< 0.7%< 0.5%< 0.2%< 0.2%< 0.2%

< 0.2%< 0.15%

< 3.3%< 1.3%< 1.6%< 1.1%< 0.6%< 0.4%< 0.4%

< 0.3%< 0.3%

< 5.0%1)

< 2.0%< 2.5%< 1.7%< 1.0%< 0.6%< 0.5%

< 0.5%< 0.3%

< ± 2.0%< ± 1.0%< ± 1.0%< ± 1.0%< ± 0.8%< ± 0.6%< ± 0.5%

< ± 0.5%< ± 0.5%

< ± 6.0%1)

< ± 2.5%< ± 2.5%< ± 2.5%< ± 1.5%< ± 1.5%< ± 1.5%

< ± 1.5%< ± 1.5%

< ± 4.0%< ± 1.5%< ± 1.5%< ± 1.5%< ± 0.9%< ± 0.9%< ± 0.6%

< ± 1.0%< ± 1.0%

0.2 – 2 μL1 – 10 μL1 – 10 μL2 – 20 μL10 – 100 μL20 – 200 μL100 – 1000 μL

0.2 – 2 mL 1 – 10 mL

822.0002822.0010822.0010Y822.0020822.0100822.0200822.1000

832.02832.10

Ultra 10 μLUltra 10 μL

200 μL200 μL200 μL200 μL1000 μL

2 mL10 mL

0.1 μL0.05 μL0.05 μL0.1 μL0.5 μL1.0 μL5.0 μL

0.01 mL0.1 mL

Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.1) measured at 0.5 μL

Calibra® digital 822

Calibra® digital 832

Performance and ordering information

Instant volume settingTwin cam system fitted with pre-calibrated steps providing for true digital volume entry and numerical display. The dual incrementation allows fast volume setting without tedious winding.

822micro

0.2 – 2 μL1 – 10 μL2 – 20 μL

10 – 100 μL20 – 200 μL

100 – 1000 μL

Key volume adjustmentExample: from 10 to 50 μL in half a revolution of the setting wheel placed in its normal position.

1

1

Fine-tuning adjustmentExample: from 50 to 55.5 μL in half a revolution of the setting wheel in its “pulled” position.

2

2

832macro

0.2 – 2 mL1 – 10 mL

The combination of instant volume adjustment, mechanical precision and ease of use makes the Calibra® digital a most reliable and robustmicropipette line in the market. Three-year warranty.

Thin shaft shape helps reach contents from microtubes and/or narrow containers. The Calibra® provides convenient access into those hard to reach places.

digital setting micro and macropipettes

Calibra®digital

www.socorex.com

Page 16: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

15

The Calibra® digital 852

Product advantages

Winding-free, instant volume adjustmentLong term performance and calibration stabilityLower assembly rotates 360° for optimal

working comfortEasy sequential tip ejectionCalibration simple to perform by userShock, UV-light and autoclaving resistanceCE certified IVD 98/79 EEC

Easy in-lab calibrationThe calibration screw is located under the rubber pad. Engraved graduations help calibrate instrument quickly and precisely. Calibration key supplied with the instrument.

Multichannel reservoirsWell adapted for multichannel pipettes, the reagent reservoirs come in various shapes and volumes. See page 36.

360° rotationIn addition to ergonomic hand fitting, the pipette lower assembly revolvesfor added user comfort.

Sequential tip ejectionSpecial shape of ejector head guarantees effortless, sequential easy tip ejection.

VolumeMax. vol. Min. vol.

Cat. No.Min. vol. Max. vol.

Division

0.05 μL0.5 μL1.0 μL

0.5 μL1.0 μL

1 – 10 μL10 – 100 μL20 – 200 μL

10 – 100 μL20 – 200 μL

< ± 3.5%< ± 1.0%< ± 0.9%

< ± 1.0%< ± 0.9%

< ± 2.5%< ± 0.9%< ± 0.9%

< ± 0.9%< ± 0.9%

< ± 1.5%< ± 0.7%< ± 0.7%

< ± 0.7%< ± 0.7%

< 3.0%< 1.0%< 0.6%

< 1.0%< 0.6%

Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.

< 1.0%< 0.4%< 0.3%

< 0.4%< 0.3%

< 2.0%< 0.7%< 0.4%

< 0.7%< 0.4%

852.08.010852.08.100852.08.200

852.12.100852.12.200

Mid. vol.Mid. vol.Inaccuracy (E%) Imprecision (CV%)

8-channel

12-channel

Performance and ordering information

852multi

1 – 10 μL10 – 100 μL20 – 200 μL

See pipette stands page 37 - 38

3

3 5

4

41 2 5 6

1 2

8- and 12-channel micropipettes with winding-free, instant volume adjustment extend pipetting possibilities in microplates. Three-year warranty.

See Qualitips® page 32 - 34 6

digital setting multichannel pipettesCalibra®digital

Page 17: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

www.socorex.com

Pipettes with ETFE-tipped plunger provide for positive displacement of sample in a precision capillary tube. Optimal accuracy and reproducibility when pipetting high-density, viscous, foaming or volatile liquids. Five models cover a range from 1 to 200 μL.Three-year warranty.

The Acura® positive 841

Product advantages

Step-wise volume adjustmentInterchangeable plunger and glass capillary Matching colour codes on pipette, plunger and capillary Stainless steel, ETFE-tipped plunger

Colour codingPipette, plunger tip and glass capillary bear colour coding for easy volume identification.

ETFE-tipped plungerChemically inert ETFE material offers excellent resistance when coming in direct contact with liquids.

Pre-set volumesEach pipette has five, easy-to-adjust pre-set volumes. Clear volume indication on pipette barrel.

Min. vol.Volumes

Min. vol. Mid. vol. Max. vol. Max. vol.Cat. No.

< 2.5%< 1.0%< 0.8%< 0.6%< 0.3%

< 2.0%< 0.9%< 0.7%< 0.5%< 0.3%

< ± 2.0%< ± 0.8%< ± 0.7%< ± 0.7%< ± 0.7%

< ± 3.0%< ± 1.5%< ± 1.2%< ± 0.7%< ± 0.7%

< ± 2.3%< ± 1.2%< ± 1.0%< ± 0.7%< ± 0.7%

1-2-3-4-5 μL5-10-15-20-25 μL10-20-30-40-50 μL60-75-80-90-100 μL100-120-150-175-200 μL

Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.

Mid. vol.

841.005841.025841.050841.100841.200

< 1.2%< 0.6%< 0.4%< 0.3%< 0.3%

Inaccuracy (E%) Imprecision (CV%)

Colour code

White2x whiteGreenBlueRed

Packaging

200 / pk200 / pk200 / pk200 / pk100 / pk

Cat. No.

341.005341.025341.050341.100341.200

Spare glass capillaries

Colour code

SteelWhiteGreenBlueRed

Packaging

5 / pk5 / pk5 / pk5 / pk5 / pk

Cat. No.

342.005342.025342.050342.100342.200

Spare plungers

Work stationFor two positive displacement pipettes (Cat. No. 320.333).

Performance and ordering information – Instruments

Ordering information – Accessories

8411 – 5 μL

5 – 25 μL10 – 50 μL

60 – 100 μL100 – 200 μL

1

1

2

3

2 3

positive displacementmicropipettes

Acura®positive

16

Page 18: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

repeater pipetteStepper™

17

The StepperTM 411

Product advantages

4-finger activationSetting knobs bear clear indication of volumes

and number of aliquots Three positive displacement syringes,

colour coded Self-locking mechanism

Clear setting indicationAfter inserting disposable syringe, select appropriate volume. Markings on interchangeable selector buttonsallow direct reading of set volume and corresponding number of aliquots.

Colour codingEcostepTM syringe andselector button bearcolour coding toeliminate anysetting error.

Highly comfortable pipette intended for reliable repeat dispensing within 10 to 5000 μL. Unique trigger action mechanism eliminates thumb fatigue. Selected materials offer outstanding shock resistance. Compact shape greatly limits internal instrument contamination. Large selection among53 different volumes; up to 73 doses per filling. Two-year warranty.

41110 – 5000 μL

7349362924201815141211109887776

No. ofaliquots

VolumeμL

VolumeμL

VolumeμL

101520253035404550556065707580859095100

5075100125150175200225250275300325350375400425450475500

50075010001250150017502000225025002750300032503500375040004250450047505000

Fingertip activationUser friendly 4-finger trigger action eliminates thumb fatigue during repeat dosing. Automatic safety lock prevents false delivery when dosing is completed.

Description

StepperTM 411 incl. 3 colour coded selector buttons, adapter, EcostepTM syringe samplesReplacement adapter for red EcostepTM syringeStand for one Stepper

Packaging

1 / pk

5 / pk

1 / pk

411.5000

1.411.7

320.411

Cat. No.

Ordering information

Volume Syringecapacity

Performanceat

Inaccuracy(E%)

Imprecision(CV%)

Sterilized Packaging Cat. No.

20 μL100 μL100 μL500 μL1000 μL5000 μL

< ± 1.5%< ± 1.0%< ± 1.0%< ± 0.5%< ± 0.8%< ± 0.5%

< 1.5%< 0.8%< 1.0%< 0.5%< 1.2%< 0.4%

noyesnoyesnoyes

100 / box100 x 1 / box

100 / box100 x 1 / box

100 / box100 x 1 / box

316.010316.010.9316.050

316.050.9316.500

316.500.9

0.75 mL

3.75 mL

37.5 mL

10 – 100 μL

50 – 500 μL

500 – 5000 μL

Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°Cin accordance with method described in EN ISO 8655.

Performance and ordering information – EcostepTM syringesOnly three sizes cover full volume range from 10 to 5000 μL. PE/PP materials. Supplied non-sterile in bulk, or sterilized, single wrapped.

STOP

1

1 2

2 3 4

4

3

Page 19: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

www.socorex.com

The Acura® manual 865

Product advantages

Excellent ergonomics, soft plunger activationLarge volume displayEasy in-lab calibrationNo need for consumablesAutoclavable fully assembled at 121°C / 250°FVersatile feeding through bottle, tubing or syringe

Description Packaging Cat. No.

1 / pk1 / pk1 / pk1 / pk

1 / pk1 / pk

1 / pk

1 / pk

1.861.6311.861.21T1.861.9251.861.720

1.861.E321.170.054

1.170.058

320.340

Reservoir*, 30 mL, PP, LuerReservoir*, 30 mL, PTFE, LuerVial holder*, LuerInlet valve cap*, female Luer(for syringe)PTFE delivery cannula*Manifold*, 4-channel, Luer Lock,stainless steel (9mm spacing)Manifold*, 8-channel, Luer Lock,stainless steel (20mm spacing)Work station 340 for 3 pipettes

*Autoclavable

Ordering information – Accessories

Hand-held, self-refilling microdispenser intended for repeat distribution of microliter volumes. Carefully selected materials ensure durability and resistance to aggressive media. Instrument combines easy handling of a regular micropipettewith flexibility of a repeater pipette. There is no need for plastic tips or consumables, which may represent substantial savings.Three-year warranty.

Convenient dispensingReliable valve system ensures highperformance dispensing, dose after dose. It revolves to allow selection of the best working position.

Min. vol.Volume

Min. vol. Mid. vol. Max. vol.Division

Max. vol.Cat. No.

< 2.0%< 1.5%< 0.6%

< 1.4%< 1.0%< 0.4%

< ± 1.5%< ± 1.0%< ± 0.6%

< ± 5.0%< ± 2.5%< ± 1.5%

< ± 3.5%< ± 1.8%< ± 1.1%

5-50 μL20-200 μL100-1000 μL

0.1 μL0.2 μL1.0 μL

Mid. vol.

865.0050865.0200865.1000

< 0.4%< 0.3%< 0.2%

Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.

Inaccuracy (E%) Imprecision (CV%)

Performance and ordering information – InstrumentsIncluding: 90 cm silicone tubing, SS blunt end cannula, female Luer inlet valve cap,Q.C. certificate and operating instructions.

Swift-set calibration system* Easy and precise system with integrated key and locking mechanism, making tedious procedures a thing of the past.

* Socorex patented

Protective calibration seal sticker

Choice of feeding sourcesSupplied with 90 cm silicone tubing, the instrument also fits optional feeding sources: bottle, vial, syringe.

Great distribution flexibilityOutlet nozzle fits any Luer Lock needles and cannulas. Optional PTFE cannula provides enhanced chemical resistance. Use 4- or 8-channel manifold whendispensing into microplates.

18655 – 50 μL

20 – 200 μL100 – 1000 μL

2

3

1 2 3

Chemical compatibility see page 25

Needles and cannulas see page 28

Excellent ergonomics Instrument shape and lightweight offer most convenient pipetting comfort. Smooth plunger activation drastically reduces hand fatigue.

1

1

2 3 4

2 3 4

Socorexcalibration

seal

self-refillingmicrodispenser pipette

Acura®manual

18

Page 20: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

The AcurexTM compact 501

Product advantages

Integrated dosing mechanismSimple, robust construction Retractable graduated column reduces instrument height Fluid path materials excluding any metalChoice of four reservoir sizesFully autoclavable at 121°C / 250°F

Autoclavable extension tubingPTFE Jet-PenTM and tubing help dispense into vessels with maximum comfort within a 60 cm distance. For 1 and 2 L reservoirs (Cat. No. 1.523).

Compact dispensers for safe reagent handling, adapted to refrigerator storage as well as water bath heating. Dosing mechanism entirely protected inside reservoir. Manufactured and tested to fully comply with the latest regulations on instrument safety and precision. Volumes range from 0.2 to 30 mL. Two-year warranty.

Valve

BarrelPlungerReservoirDelivery jet and union

Pyrex glass and synthetic rubyNeutral glassPTFE-coated glassAmber glassPVDF / FEP / PFA

MaterialsParts

Volume Division

Min. vol. Mid. vol.

Imprecision (CV%)

Max. vol.

< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%

< 0.5%< 0.5%< 0.5%

< 0.5%1)

< 0.5%1)

< 0.5%1)

< 0.5%< 0.5%

< 0.5%2)

< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%

0.1 mL0.1 mL0.1 mL0.2 mL0.2 mL0.2 mL0.2 mL0.2 mL1.0 mL

Reservoircapacity

250 mL1000 mL2000 mL500 mL1000 mL2000 mL1000 mL2000 mL2000 mL

Cat. No.

501.02025501.021501.022501.0505501.051501.052501.101501.102501.302

0.2 – 2 mL0.2 – 2 mL0.2 – 2 mL0.4 – 5 mL0.4 – 5 mL0.4 – 5 mL1 – 10 mL1 – 10 mL1 – 30 mL

Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between20 and 25°C in accordance with ISO 8655. 1) measured at 0.5 mL 2) measured at 3 mL

Performance and ordering information

Space saving low profileThe graduated column is retractable for height reduction, making the dispenser ideal for storage in refrigerators.

Chemically inert materialsAll parts in contact with the liquid are made from chemically inert materials:

Glass reservoirAmber glass offers optimal light protection.

5010.2 – 2 mL0.4 – 5 mL1 – 10 mL1 – 30 mL

Chemical compatibility

see page 25

1

1 2 3 4

2 3 4

low-profile dispensersAcurex™compact

19

Page 21: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

www.socorex.com

20

The CalibrexTM 520

Product advantages

Superior chemical resistanceLong-lasting performance stability Simple construction – no tool for disassembling Instant volume settingIn-lab calibrationAutoclavable at 121°C / 250°F fully assembled

Designed for performance handling of liquids from a large variety of bottles and flasks, the Calibrex™ dispenser combine the latest in dosing technology, high-tech materials and ergonomic design. They are manufactured and tested to fully comply with current safety regulations. Fixed versions also available in any volume within these ranges. Two-year warranty.

Large display is easy to read; the window adjusts to desired side of instrument body. Each step on the cylindrical cam is pre-calibrated and corresponds to one division on the volume adjustment scale.

Friendly digital volume settingFast and precise volume adjustment. Efficient click-stop mechanism prevents unwanted alteration.

Air filterAir inlet can be enlarged to receive a membrane filter, if airborne contamination is a concern.

Easy maintenance Disassembling / reassembling is facilitated by the limited number of well-connected parts - no tool needed.

Superior material selection Special attention is paid to component materials, providing for long instrument life. Parts coming in contact with the liquid flow are chemically inert.

5200.25 – 2 mL

1 – 5 mL1 – 10 mL

1

1 3

4

5

6

2

2

3 4 5 6

bottle-top dispensersCalibrex™digital

Min vol.Volume Division

Min. vol. Mid. vol. Max. vol.

< 0.5%< 0.5%< 0.5%

Mid. vol. Max. vol.

< 0.1%< 0.1%< 0.1%

< ± 0.6%< ± 0.6%< ± 0.6%

< ± 3.0%< ± 2.0%< ± 1.5%

< ± 1.8%< ± 1.3%< ± 1.1%

< 0.35%< 0.35%< 0.35%

0.05 mL0.1 mL0.25 mL

0.25 – 2 mL1 – 5 mL1 – 10 mL

Cat. No.Adj.

volume520.002520.005520.010

Cat. No.Fixed

volume*520.F02520.F05520.F10

Inaccuracy (E%) Imprecision (CV%)

* Specify desired fixed volume within instrument range when ordering. Performance values obtained with bidist. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.

Performance and ordering informationCalibrex™ have a 32 mm base thread. They come with three adapters: 28, 40, 45 mm and feed tube 300 mm.

Parts Materials

Feed tubeIntake valveValve ballsValve springBarrelBarrel plate / basePlungerOutlet valveBodyDelivery jet assembly

PTFECeramicPyrex glassPlatinum-iridiumBorosilicate glassPTFEGlass with PFA coatingCeramicETFEPTFE/ETFE

Large selection of bottles

see page 24

In-lab calibrationCalibrexTM dispensers are factory cali-brated and can be easily recalibrated by means of a dedicated adjustment screw.

Optimised working positionThe instrument rotates 360° for adequate positioning on top of the bottle.

Page 22: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

21

bottle-top dispensersCalibrex™

a

c

b

1 3 52 4 6

The CalibrexTM 525 / 530

Product advantages

Selection between two different modelsPermanent fluid path visibilityIntegrated calibration systemChoice of adjustment button with each unitFlow control system with stopcock (optional)QR code accessing compatibility chartAutoclavable at 121°C / 250°F fully assembled

The new generation of robust instruments with excellentchemical resistance, high performance and easy maintenance. Fitting most reagent bottles, it enables safe and reproducible dispensing within volumes up to 25, 50 and 100 mL. Choose between the organo and the solutae models foradequate resistance to liquid dispensed. Two-year warranty

525 / 5302.5 – 25 mL

5 – 50 mL10 – 100 mL

Ease of useSmooth aspiration and distribution for trouble-free routine dispensing. Dual scale enables volume reading from a wide angle.

Choice of setting buttons Sliding cursor softly moves up and down scale and precisely stops at desired graduation. Installed on each unit. Alternative classical screwbutton supplied with each dispenser as an accessory. Easy to exchange by user.

Permanent visibility Safety transparent thick sleeve around barrel and delivery jet window allow liquid flow monitoring.

Optimal working position The instrument rotates 360° for adequate positioning on the bottle. Free rotating dispenser body makes volume clearly visible from any position.

Flow control stopcockNext to its dispensing position (b), device enables liquid priming and recycling (a) without reagent loss or contamination. Locking position (c) for safe dispenser transportation.

1

3

4

5

62

Page 23: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

www.socorex.com

22

bottle-top dispensersCalibrex™

1

1

3

5

42

2

3 5

Chemical compatibility see page 25

Easy In-lab calibration Access protected by safety seal sticker. Mechanism with integrated key located under plunger cap. Engraved +/- arrows for easy and precise setting.

Performance and ordering information - CalibrexTM 525 and 530 Supplied with 45 mm base thread, 120 mm delivery jet and stopper, 350 mm feed tube, alternative screw-type volume setting button, three bottle neck adapters (32, 38 and 40 mm), QC certificate and operating instructions. Both models available with and without stopcock.

MaintenanceDisassembling/reassembling facilitated by limited number of parts – no tool needed. Key elements such as valves, plunger, barrel and delivery jet removable in seconds for cleaning. Fully autoclavable at 121°C / 250°F.

Model differentiation

Material selectionParts in contact with liquid flow are chemically inert, providing for stability and long instrument life.

Chemical resistance Scan QR code to access chemicalresistance chart.

Air filter Air inlet can be enlarged to receive a membrane filter, if airborne contamination is a concern.

Parts 525 organo 530 solutae

FEPCeramicCeramic

Platinum-iridiumPTFE

Borosilicate glass Ground glass PFA coated glass

ETFEFEP / PCTFE

ETFE

Feed tubingValve bodyValve ballsValve springValve plateBarrelPlungerConnecting bodyDelivery jetStopper

* Except hydrofluoric acids (HF)

organo solutaeOrganics Non-crystallizing sol. Inert reagents Salt solutions Strong acids* & bases

FEP feed tubing

Air inlet for filter connection

Calibration safety seal sticker Colour coding by model

Screw-type volume adjustment button (interchangeable, as alternative supplied with all models)

PFA coated plunger

Transparent safety sleeve

Flow control stopcock

Integrated calibration key under cap

Dual graduation

Volume adjustment sliding cursor (pre-mounted)

Ground glass plunger

Disassemblingnut, no toolneeded

Screw-lockingstopper Liquid viewing window

360° rotation on bottle 4

2.5-255-5010-100

0.51.01.0

< ± 1.5%< ± 1.5%< ± 1.5%

< ± 1.1%< ± 1.1%< ± 1.1%

RangemL

DivisionmL Min.vol Mid.vol Max.vol Min.vol Mid.vol Max.vol Regular (no stopcock) With stopcock Regular (no stopcock) With stopcock

Imprecision (CV%) Calibrex™ organo 525 Calibrex™ solutae 530Inaccuracy (E%)

< ± 0.6%< ± 0.6%< ± 0.6%

< 0.5%< 0.5%< 0.5%

< 0.35%< 0.35%< 0.35%

< 0.1%< 0.1%< 0.1%

525.025525.050525.100

525.025FC525.050FC525.100FC

530.025530.050530.100

530.025FC530.050FC530.100FC

Performance values obtained by a smooth and steady pace movement, with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C, according to EN ISO 8655.Warning: omission to untighten connecting body ring before autoclaving, and / or over-tightening ring when dispensing, may reduce performance.

Page 24: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

Flow control stopcockDevice compatible with any CalibrexTM 525 / 530. Enables liquid priming and recycling without reagent loss or contamination. No tool needed to assemble or to remove for cleaning. Fully autoclavable.

Delivery jetStandard (120 mm) and extended (150 mm) assemblies are exchangeable without any tool. Fully autoclavable.

Extension tubingTubing and delivery Jet-PenTM, helpdispense into vessels with maximum comfort within a 60 cm distance. No tool needed to assemble or to remove for cleaning. Fully autoclavable.

Description Pack Cat. No.

320.SB050320.SB100

320.BC050320.BC1001.525.581

1 / pk1 / pk

1 / pk1 / pk1 / pk

* Dispenser and feed tubing / connector to beordered separately

Work station for dispenser stabilityFits Calibrex™ 520 dispenserFits Calibrex™ 525/530 dispensersWork station for remote liquid intakeFits Calibrex™ 520 dispenser*Fits Calibrex™ 525/530 dispensers*Connector and remote feed tubingfor Calibrex™ 525/530

Description Pack Cat. No.

1.525.546

1.525.1201.525.121

1.525.1501.525.151

1 / pk

1 / pk1 / pk

1 / pk1 / pk

Flow control stopcock, fits Calibrex™ 525 / 530

For all modelsDelivery jet assembly, 120 mm, fits Calibrex™ 525/530

For 25 mL dispenserFor 50, 100 mL dispensersDelivery jet assembly, extended, 150 mm, fits Calibrex™ 525/530

For 25 mL dispenserFor 50, 100 mL dispensers

Description L./Mat. Cat. No.

1.524

1.525.625

1.525.650

int. Ø

2.2 mm

4 mm

4 mm

600 mmPTFE

600 mmFEP/PCTFE600 mm

FEP/PCTFE

Extension tubing and Jet-Pen™

Fits Calibrex™ 520/521up to 20 mLFits Calibrex™ 525/530up to 25 mLFits Calibrex™ 525/53050 and 100 mL

Dispenser stability Stand holds dispenser when screwed on small-size bottle.Remote aspiration Work station facilitates liquid intake from drum or other remote container (< 10 m distance, < 2 m elevation).

accessoriesCalibrex™digital

23

4

5

5

4

1

1 2

2

3

3

60 cm

Page 25: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

1

CalibrexTM 520 have a 32 mm base thread. They come along with threePP material bottle neck adapters in 28, 40 and 45 mm diameters. For other bottle neck diameters, simply orderthe appropriate adapter size.

Bottle-neck adapters CalibrexTM 525/530 have a 45 mm base thread. They come along with three PP material bottle neck adapters in 32, 38 and 40 mm diameters. For other bottle neck diameters, use 32 mm adapter (cat. No. 1.525.GL32) nested with any CalibrexTM 520 adapters.

Calibration seal stickers Autoclavable seal sticker protects access to the calibration mechanismof CalibrexTM 525/530 models.

Replacement tubing Feed tubing available either cutto the standard size, or uncutby the meter.

Description Length Cat. No.

525.350525.706

511.707521.621521.622521.623511.709

521.705

521.706

int. Ø

7 mm7 mm

5 mm

7.5 mm10 mm10 mm 5 mm

7.5 mm

10 mm

350 mmspecify

300 mm300 mm300 mm375 mmspecify

specify

specify

Feed tubing, FEP, for Calibrex™ 525/530

For all sizes, cutFor all sizes, by themeter, uncutFeed tubing, PTFE, for Calibrex™ 520/521

For 520 all sizes, cutFor 521, 20 mL, cutFor 521, 50 mL, cutFor 521, 100 mL, cutFor 520 all sizes, by the meter, uncutFor 521, 20 mL, by the meter, uncutFor 521, 50 and 100 mL,by the meter, uncut

Type Ext. Ø of bottle neck Cat. No.

1.525.GL321.525.GL381.525.GL40

GLP + ØGLT + ØNSP + ØNST + Ø

32 mm38 mm40 mm

22, 25, 28, 30, 34, 36, 38, 40, 45 mm

36, 38, 40, 45 mm18.8, 24, 29.2, 45 mm

18.8, 24, 29.2 mm

Adapters for Calibrex™ 525/ 530

Threaded, PPThreaded, PPThreaded, PPAdapters for Calibrex™ 520 / 521

Threaded, PPThreaded, PTFETapered, PPTapered, PTFE

Description Pack Cat. No.

1.525.5251.525.526

25 / pk100 / pk

Safety seal stickerSafety seal sticker

www.socorex.com

24

Neck,ext. ø

Cat. No.

32 mm32 mm32 mm45 mm45 mm

45 mm

32 mm45 mm45 mm

Volume

100 mL250 mL500 mL1000 mL2500 mL

2500 mL

500 mL1000 mL2500 mL

SquareSquareSquareSquareRound

Round

SquareSquareRound

314.0100314.0250314.0500314.1000314.2500

314.2500H

314.0500PE314.1000PE314.2500PE

Shape

Amber glass1)

Amber glass, with handle1)

PE-coated Amber glass2)

45 mm45 mm45 mm45 mm

32 mm

25 mm25 mm32 mm45 mm

250 mL500 mL1000 mL2000 mL

500 mL

250 mL500 mL1000 mL2500 mL

RoundRoundRoundRound

Round

SquareSquareSquareSquare

314.0250C314.0500C314.1000C314.2000C

314.0500P

315.0250315.0500315.1000315.2500

Clear Borosilicate glass1)

Clear Pyrex glass, with connection neck1)

Polyethylene2)

1) autoclavable, 2) not autoclavable

Reagent bottlesLarge selection of glass and polyethylene reagent bottles, each supplied with one screw cap. Perfectly adapted with all bottle top dispensers. Corresponding neck adapters supplied with the dispensers.

1

42

2 3

3

4

5

5

Page 26: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

25

chemical resistance chartMicrodispenser and dispenser

Technical risks1 = Possible crystallisation, valve or plunger blockage. Scratches on plunger coating if plunger/barrel dried and stick together.2 = Swell of plunger coating, possible peeling. Acura® 865: chemical degradation of O-ring.3 = Release of acid vapours (risk increases with concentration). Do not leave dispenser on bottle. Acura® 865: limited dosing cycles, possible plunger blockage and/or corrosion.4 = Damage, softening or discoloration of external parts through vapours. Do not leave dispenser on bottle. Acura® 865: vapours may damage internal and external parts of upper assembly.5 = Chemical degradation of glass parts (plunger/barrel).

Compatibility statementA = Good resistance B = Acceptable with limitations C = Not recommended

Acura865

Acurex501

AB/2

B/2/4B/4B/4A

B/4AAAA

B/4A

C/2/4A

B/4B/4B/4A

B/1B/4B/4

B/2/4B/4B/4B/4B/4

B/3/4B/3/4

AC/1B/4B/4B/4AAAA

B/4B/4B/4A

B/4B/4AAAAAA

B/4AAAA

B/3C/5B/2

Acetaldehyde (Ethanal)Acetic acid 96%Acetic acid 100% (Glacial)Acetone (Propanone)Acetonitrile (MECN)Amino acidsAmmonium hydroxide (amonia)Amyl alcohol (Pentanol)AnilineAscorbic acidBenzaldehydeBenzeneBoric acid 10%BromineButanolButanone (MEK)Butyl acetateN-ButylamineCalcium chlorideCalcium hydroxideCarbon disulfideCarbon tetrachlorideChlorine dioxideChlorobenzeneChlorobutaneChloroethanolChloroformChlorosulfuric acid 100%Chromic acid 100%Citric acidCyanoacrylateCyclohexaneCyclohexanone1,4-Dioxane (Diethylene dioxide)DichlorobenzeneDichloroethane (DCE)Diesel oil (Heating oil)Diethylene glycolDiethyletherDimethyl sulfoxide (DMSO)Dimethylformamide (DMF)EthanolEtherEthyl acetateEthylenediamineEthylene glycolFormaldehyde (Formalin)FormamideFormic acidGamma-butyrolactoneGasolineGlycerin <40%HeptaneHexaneHydrochloric acid 20%Hydrochloric acid 37% (HCI)Hydrofluoric acid (HF)Hydrogen peroxide

Chemicals A - H Calibrex520 525 530

AA

B/4B/4B/4C/1B/4AA

C/1A

B/4B/1C/4A

B/4B/4B/4C/1C/1B/4B/4B/4B/4B/4B/4B/4

B/3/4B/3/4B/1C/1B/4B/4B/4AAAA

B/4B/1/4B/4A

B/4B/4AAAAAA

B/4AAAA

B/3C/5A

AAA

B/4AAAAAAA

B/4A

B/2A

B/4A

B/4A

B/1AA

B/2/4AAA

B/4B/3B/3A

C/1AAAA

B/4AAAA

B/4A

B/4AAAAAAAAAAAAA

C/5A

AAAAAAAAAAAAA

B/2AAA

B/4B/1B/1AA

B/2/4AAAA

B/2/3B/2/3

AC/1AAAA

B/4AAAAAAAAAAAAAAAAAA

B/2/3B/2/3C/5A

C/2B/2

B/2/3C/2/3B/2

B/1/4C/2A

B/2B/1C/2C/3

B/1/4B/2/3B/2/3C/2C/2

C/2/4B/1/4B/1/4

B/2/3/4C/3

C/2/4B/2B/4B/2

C/2/4C/4B/4A/1

C/1/2/4B/2/3C/2C/2B/4B/4B/3B/4C/2

B/1/2/4C/2/4B/2/4C/2/3

C/2/3/4C/2B/4A

B/2/4C/2/4C/2/4C/3A

B/3B/3C/4C/4

C/2/4B/3/4

Acura865

Acurex501

Chemicals I - Z Calibrex520 525 530

B/1C/2/4

AA

B/4AAA

B/4B/4A

B/2/4C/2/3/4

B/4B/2/4

AAAA

B/4B/4A

B/4B/4A

B/4B/4A

B/4AA

B/1AA

B/1AA

B/4B/4AAAAA

B/4A

B/2/3/4B/2/4B/4

B/2/4B/4B/4B/4B/4B/4A

B/4B/2/4

C/1C/4AA

B/4C/1AA

B/4B/4A

B/4C/3/4B/4B/4AAAA

B/4B/4C/1B/4B/4A

B/4B/4A

B/1/4A

C/1C/1C/1C/1C/1AA

B/4B/4A

C/1C/1C/1C/1C/1C/1

B/3/4B/4B/4B/4B/4B/4

B/1/4B/4B/4A

B/4B/4

AC/2/4

AAAAAAAA

B/4B/2/4B/3A

B/3AAAAAAA

B/4B/3AAAAAAAA

B/1AAAAA

B/4A

B/1AA

B/1AA

B/2/3B/2B/4

B/2/4B/4B/4A

B/4B/4A

B/3B/4

AC/2/4

AAAAAAAA

B/4A

B/2/3A

B/2/3AAAAAAA

B/4B/2/3

AAAAAA

B/1A

B/1AAAAA

B/4AAA

B/1B/1AA

B/2/3B/2/3B/4

B/2/4A

B/4A

B/4AA

B/3A

B/1/2/3/4C/2/4B/3A

B/2/4C/1/4B/2/4C/2/4C/3/4C/2/4

C/2/3/4C/3/4B/2/4B/2/4C/4B/4B/3AA

B/2B/2

B/1/4B/3/4B/4B/4B/3C/3

B/2/3/4B/1/4B/3/4C/1/4B/1/2B/1/2B/1/4

C/1/2/4B/4A

B/2/4C/2/4

---C/1

C/1/2B/1/4C/1/2

C/1/2/4B/1/4B/2/4B/3/4B/2/4C/2/4

C/2/3/4C/3

C/1/2/4C/3

B/2/4B/2/4B/2/4

C/2/3/4

IodineIodine bromide / chlorideIsooctaneIsopropanolIsopropylamineLactic acid2-MethoxyethanolMethanolMethyl chloride (Chloromethane)Methyl methacrylate (MMA)Methyl propyl ketone (2-Pentanone)Methylene chloride (Dichloromethane) (DCM)Nitric acid 100%Nitric acid dil. <30%Nitro-hydrochloric acid (Aqua regia)N-methyl-2-pyrrolidone (NMP)OctaneOctanolOil, mineral (engine oil)Oil, vegetable, animalOil of turpentineOxalic acidPentanePerchloric acid 100%Perchloric acid dilutedPetroleumPetroleum ether / spiritPhenolPhenylhydrazinePhosphoric acid 85%Potassium chloridePotassium dichromatePotassium hydroxidePotassium iodidePotassium permanganatePropionic acid (Propanoic acid)Propylene glycol (Propane-1,2-diol)Picric acid (Trinitrophenol)PyridineScintilation fluidSilver nitrateSodium acetateSodium chloride (Kitchen salt)Sodium hydroxide 30%Sodium hypochlorite (Javel water)Sodium thiosulfateSulfonitric acid 100%Sulfuric acid 98%TetrachloroethyleneTetrahydrofuran (THF)TolueneTrichlorethyleneTrichloroacetic acidTrichloroethaneTrichloromethane (Chloroform)Triethylene glycolTrifluoroacetic acid (TFA)Xylene

Acura® 865

CalibrexTM 520/521AcurexTM 501

CalibrexTM 525/530

Expanded chemical lists

Page 27: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

www.socorex.com

The DosysTM syringes

Product advantages

Optimal hand balance and ergonomicsFast and reliable volume setting Excellent reproducibilityPlunger tightness without O-ringHigh chemical resistanceFully autoclavable at 121°C / 250°F

Simple, natural movementsBoth pistol-grip and two-ring handles fit any hand in a comfortable way. Activation performed with limited effort for efficient work even during long dispensing series.

Syringe standStand holds syringe in ready-to-fetch position. Easy-to-clean material. Autoclavable (Cat. No. 320.170).

Volume selection – Reliable

reproducibilityVolume is set within seconds. It will not vary while activating the syringe, thanks to the safety-locking nut on the micrometric screw. Dose-by-dose reproducibility (CV) is excellent, as witnessed by performance figures.

Plunger tightness without

O-ringSmooth plunger travel and tightness achieved through high-precision stainless steel plunger and ground glass barrel. No O-ring to mess with or replace.

Glass protectionInterchangeable glass barrel is protected by a PVC sleeve (not autoclavable) to prevent breakage.

Few parts assembly –

Low maintenanceThe automatic syringes are made of only six main parts, easy to disassemble. Fast access to all elements allows rapid and efficient cleaning. Spares are available at reasonable cost.

From the basic unit to the corrosion-resistant model, the laboratory dedicated syringe line offers precision instruments you can trust. Intended for safe and reliable liquid distribution, the selection of pistol-grip and two-ring instruments comes in a wide volume range. One-year warranty.

162 163 164

Two-ring handle

172 173 174Pistol-grip handle

1

1 2 5

3

4

6

3 4 5 62

laboratory syringesDosys™

26

Page 28: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

Division Dosys 164Cat. No.

Dosys 174Cat. No.

174.0501174.0502174.0505174.0510

164.0501164.0502164.0505164.0510

0.05 mL0.1 mL0.5 mL1.0 mL

0.1 – 1 mL0.3 – 2 mL0.5 – 5 mL1 – 10 mL

VolumeVolume Division Dosys 162Cat. No.

Dosys 172Cat. No.

172.0501172.0502172.0505172.0510

162.0501162.0502162.0505

0.05 mL0.1 mL0.5 mL1.0 mL

0.1 – 1 mL0.3 – 2 mL0.5 – 5 mL1 – 10 mL

Division Dosys 163Cat. No.

Dosys 173Cat. No.

173.05003173.05005173.0501173.0502173.0505173.0510173.0520

163.05003163.05005163.0501163.0502163.0505163.0510

0.025 mL0.1 mL0.05 mL0.1 mL0.5 mL1 mL1 mL

0.025 – 0.3 mL0.1 – 0.5 mL0.1 – 1 mL0.3 – 2 mL0.5 – 5 mL1 – 10 mL5 – 2 0 mL

Volume

DosysTM basic syringes 162 / 172Fill-by-fill (automatic) through needle

or cannulaSupplied without valve systemLuer Lock nozzle

Package includes syringe, PVC protection sleeve and operating instructions.

Dose-by-dose distribution

Dispensing distribution Sterile work Filtration at yournozzle tip

Aspiration with reverse modus valve

Animal injection

DosysTM classic syringes 163 / 173Self-refilling automaticIntegrated valve systemLuer Lock nozzle

Package includes syringe, one meter silicone feed tube, sinker, PVC protection sleeve, aspiration and vent cannulas, set of spares for valve, operating instructions.

DosysTM premium syringes 164 / 174Self-refilling automaticDetachable valve systemEnhanced corrosion resistanceLuer Lock nozzle

Package includes syringe, one meter silicone feed tube, sinker, PVC protection sleeve, aspiration, vent and dosing cannulas, set of spares for valve, operating instructions.

Parts

Feed tubingBarrelWasher, barrelPlungerValve systemWasher, valveSpring and balls, valveSinker, feed cannula

Basic / classic models

SiliconeBorosilicate glass

FPMStainless steel DIN 304

Ni-Cr BrassPTFE

Stainless steel, DIN 304Ni-Cr Brass

Premium models

SiliconeBorosilicate glass

FPMStainless steel DIN 316LStainless steel DIN 316L

PTFEStainless steel, DIN 304

Ni-Cr Brass

Liquid path materials (for chemical resistance)Performance all modelsVolume

Min. vol. Max. vol.< 0.5%< 0.4%< 0.4%< 0.4%< 0.2%< 0.2%< 0.4%

< 1.2%< 0.9%< 0.6%< 0.5%< 0.4%< 0.4%< 0.4%

< 1.8%1)

< 1.2%< 0.7%< 0.6%< 0.5%< 0.5%< 0.5%

0.025 – 0.3 mL0.1 – 0.5 mL0.1 – 1 mL0.3 – 2 mL0.5 – 5 mL1 – 10 mL5 – 20 mLTests performed with bidest. water, using stainless steel cannula (1.2x50 mm), at constant working speed. 1) Measured at 0.075 mL

Imprecision (CV%)Mid. vol.

DosysTM laboratory syringes – Unlimited applications

Instrument descriptions and ordering informationCorrosion

resistant

Corrosion

resistant

27

Page 29: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

Description

Set includes one each plunger, X-ring,5 mL barrel and greaseSpare barrel for tightness set, 5 mL

Packaging

1 / pk

6 / pk

Cat. No.

1.170.205

0187.05T

Description Packaging Cat. No.

Lubricant spray, 70 mLMultipk: Lubricant spray, 70 mLMultipk: Lubricant spray, 70 mL

1 / pk6 / pk12 / pk

1.170.7051.170.9061.170.912

Size Ø x L, mm Packaging Cat. No.

3.0 x 180 mm3.0 x 500 mm

1 / pk1 / pk

370.30180370.30500

28

www.socorex.com

Multiple dispensing manifoldsFor convenient distribution in 24- and 96-well plates. Tight-fitting Luer and Luer Lock syringe nozzles. Stainless steel with PTFE stoppers, autoclavable.

Injection needlesBeveled, high-quality needles, stainless steel, autoclavable. 12 / pack.

Cannula with sprayer nozzleLuer Lock, stainless steel, autoclavable.

Dispensing needles & cannulasLuer Lock, stainless steel, autoclavable.

Cleaning brushesHeavy-duty nylon brushes with tufted end and plastic handle for barrel cleaning.

DrenchersFor safe animal mouth- and nose- feeding. Stainless steel, autoclavable.

Accessories for self-refilling syringes

Description

4-channel manifold,20 mm spacing8-channel manifold,9 mm spacing

Packaging

1 / pk

1 / pk

Cat. No.

1.170.054

1.170.058

ø x L, mm Cat. No.

371.0713371.0810371.0825371.0830371.0840371.1010371.1020371.1030371.1040371.1210371.1220371.1235371.1250

Additional sizes available

0.7 x 130.8 x 100.8 x 250.8 x 300.8 x 401.0 x 101.0 x 201.0 x 301.0 x 401.2 x 101.2 x 201.2 x 351.2 x 50

ø x L, mm Cat. No.

371.1420371.1435371.15150371.1620371.1625371.1630371.16100371.1810371.1820371.1830371.2030371.2040371.2050

1.4 x 201.4 x 351.5 x 1501.6 x 201.6 x 251.6 x 301.6 x 1001.8 x 101.8 x 201.8 x 302.0 x 302.0 x 402.0 x 50

Size (ø x L) Packaging

12 / pk1 / pk1 / pk1 / pk

1 / pk1 / pk1 / pk

Cat. No.

370.0840370.1250370.22100370.22150

371.1210UN371.1620UN371.2030UN

0.8 x 40 mm1.2 x 50 mm2.2 x 100 mm2.2 x 150 mm

1.2 x 10 mm1.6 x 20 mm2.0 x 30 mm

Lab cannulas, blunt end

Superior quality needles, bevelled

Size (ø x L) Packaging

3 / pk3 / pk2 / pk2 / pk

3 / pk3 / pk2 / pk2 / pk

Cat. No.

376.0925S376.1251S376.16102S376.30203S

376.0925B376.1251B376.16102B376.30203B

0.9 x 25 mm1.2 x 51 mm1.6 x 102 mm3.0 x 203 mm

0.9 x 25 mm1.2 x 51 mm1.6 x 102 mm3.0 x 203 mm

Drenchers, straight

Drenchers, bent

Alternative feed sourcesOptional vial holder conversion setand reagent reservoirs for additional liquid feeding possibilities.

Description

Vial holder conversion set for 163 and 173 models (except 20 mL), without vialPP bottle, 60 mLPP bottle, 125 mLPP bottle, 250 mL

Packaging

1 / pk

1 / pk1 / pk1 / pk

Cat. No.

1.187.1C

1.187.060*1.187.150*1.187.250*

*Use with Rotlauf inlet valve (Cat. No. 187.613) only, to be ordered separately.

Enhanced tightness setThe special clear glass barrel / X-ring fitted plunger enhance tightness when demanded by application (ex. filtration, aspiration, etc.).

ABF premium anti-corrosive

lubricant for metal plunger

Aspiration valveReverse modus valve set for liquid aspira-tion (ex. waste collection in separate con-tainer). Vented waste collector cap and enhanced tightness set recommended.

Description

Reverse modus aspiration valve unit for 164 / 174 modelsScrew cap ø 45 mm, with tubing connection and filtered air outlet

Packaging

1 / pk

1 / pk

Cat. No.

1.170.952

1.170.945

Description

For 0.3, 0.5, 1 mL barrelsFor 1, 2, 5 mL barrelsFor 5, 10, 20 mL barrelsSet of 6 nylon brushes, 2 each

Packaging

6 / pk6 / pk3 / pk6 / pk

Cat. No.

1.170.3011.170.3051.170.3201.170.300

1

1 2 3 5 6

7 8

2 3 4

9

5 6

7

8

4

9

10

10 11

11

accessoriesDosys™

Page 30: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

155.0301

155.0305155.0310155.0320155.0330

155.03100

3 / pk3 / pk3 / pk3 / pk2 / pk2 / pk1 / pk1 / pk1 / pk1 / pk1 / pk

0.05 mL0.1 mL0.2 mL0.2 mL1 mL2 mL2 mL10 mL10 mL10 mL10 mL

0.1 - 1 mL0.5 - 2 mL0.2 - 5 mL1 - 10 mL1 - 20 mL1 - 30 mL1 - 50 mL10 - 100 mL10 - 150 mL10 - 200 mL10 - 250 mL

155.0501155.0502155.0505155.0510155.0520155.0530155.0550155.05100155.05150155.05200155.05250

Glass LuernozzleCat. No.

Volume Division Packaging Metal LuerLock nozzle

Cat. No.

Other spare partsRefer to separate list for exhaustive selection.

Includes springs, balls, washer for valve and barrel washer.

Description Packaging Cat. No.

6 / pk6 / pk6 / pk6 / pk6 / pk6 / pk3 / pk

0187.0030187.0050187.010187.020187.050187.100187.20

Barrel, syringe 0.3 mLBarrel, syringe 0.5 mLBarrel, syringe 1 mLBarrel, syringe 2 mLBarrel, syringe 5 mLBarrel, syringe 10 mLBarrel, syringe 20 mL

Description Packaging Cat. No.

1 bag1 bag1 bag1 bag1 bag1 bag1 bag

1.187.720031.187.720051.187.72011.187.72021.187.72051.187.72101.187.7220

Kit for valve, syringe 0.3 mLKit for valve, syringe 0.5 mLKit for valve, syringe 1 mLKit for valve, syringe 2 mLKit for valve, syringe 5 mLKit for valve, syringe 10 mLKit for valve, syringe 20 mL

Description Packaging Cat. No.

6 / pk6 / pk6 / pk6 / pk6 / pk3 / pk

1.170.40051.170.4011.170.4021.170.4051.170.4101.170.420

Sleeve, 0.3, 0.5 mL barrelsSleeve, 1 mL barrelsSleeve, 2 mL barrelsSleeve, 5 mL barrelsSleeve, 10 mL barrelsSleeve, 20 mL barrels

Description Packaging Cat. No.

1 / pk

1 / pk

1 / pk

1 / pk

1 / pk

Short vent cannulas

Long feed cannulas

187.933

187.591

187.593

187.592

187.594

Plastic / SS, syringes 0.3 to 5mLChrome plated, syringe 10 mLChrome plated, syringe 20 mL

Chrome plated, syringes 0.3 to10 mLChrome plated, syringe 20 mL

Description Packaging Cat. No.

1 m / pk3x 1 m / pk10 m / pk

by the meter1 m / pk

187.705187.905187.910187.710187.707

Tube, syringes 0.3 to 10 mL, cutTube, syringes 0.3 to 10 mL, cutTube, syringes 0.3 to 10 mL, uncutTube, syringes 0.3 to 10 mL, cutTube, syringe 20 mL, cut

The DosysTM all-glass syringes

The reusable borosilicate glass syringes offer superiorchemical and heat-shock resistance. A precious, low-cost alternative to disposable plastic syringes, complementing the self-refilling models in many applications.

Product advantages

Precision-machined plunger and barrelExcellent fitting and liquid tightness (not gas tight) Permanent, high-visibility graduationsSterilisation up to 160°C / 320°F

Ground glass barrels

Spare parts for self-refilling syringes

Spare bags Vent and feed cannulas

1551 to 250 mL

PVC protection sleeves Feed tubing (medical quality silicone)

Ordering information

1

1

2 4

3 5

2 3 4 5

spare parts and all-glass syringesDosys™

29

Page 31: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

www.socorex.com

The ProfillerTM electro 446

Product advantages

Powerful pump – fills 25 mL in 3 secondsSimple, fast operation Comfortable finger triggersLow battery lightNiMH battery rechargeable during useInterchangeable protection membrane filterStand suitable for bench or wall mounting

Battery chargeInstrument plug enables charging bat-tery either in storage positionor during use.

Variable speedSwitch enables selection of fastor slow aspiration and dispensing(with blow-out). Fast speed filling upto 25 mL in under 3 seconds. Gravitydispense mode is designed for use with‘To Deliver’ (TD) pipettes.

Ordering information – InstrumentSupplied with power supply, two sparehydrophobic filters (0.45 μm and 0.2 μm), bench / wall stand and instruction manual.

Ordering information – Accessories

Finger triggersSuction and dispensing are controlled through two ergonomically positioned finger triggers. They provide a comfortable grip with minimum activation effort.

Convenient standSuitable for bench or wall mounting, stand houses ProfillerTM electro withor without a pipette in place.

Pipette controller fitting any hand in a very comfortable way. Shape is ideal for working with glass or plastic pipettes within laminar flow or microbiological safety cabinet. A powerful, yet quiet motor and a switch to set both aspiration and dispensing speeds enable maximal working efficiency even with large pipetting volumes.One-year warranty.

Description Packaging Cat. No.

1 / pk2 / pk

1 / pk

1 / pk

1 / pk

320.446900.916

900.946E

900.946G

900.946U

Spare standSpare 1.2V NiMH batteryPower supply, Europe style plugPower supply, UK style plugPower supply, USA-Japan style plug

Description Packaging Cat. No.

5 / pk5 / pk1 / pk3 / pk3 / pk

322.435322.4001.435.011.435.021.435.03

Membrane filter, 0.45μmMembrane filter, 0.2μmSilicone pipette holderNose cone – whiteAlternative nose conespink, violet, green (1 each)

ProfillerTM electro 446 Packaging Cat. No.

1 / pk1 / pk1 / pk

446.100E446.100G446.100U

With Europe style plugWith UK style plugWith USA/Japan style plug

446Pipettes

up to 100 mL

1

1

2 3

2 3

electronic pipette controllerProfiller™electro

30

Page 32: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

Squeezable bulbSimply squeeze large capacity silicone bulb for efficient aspiration. If additional aspiration is needed, it can be squeezed even during pipetting.

Precise control Thumb lever button for left and right-handed users to easily control both aspiration and dispensing speeds.

Colour coding cones Nose cone can be changed for individ-ual, laboratory or department identifica-tion. Choose among regular white or a bunch of three colours.

Ordering information

Accessories

Liquid blow-out Press large button to expel residual liq-uid when using blow-out type pipettes.

Pipette holder Conical shape of silicone pipette holder tightly fits graduated glass or plastic pipettes. Autoclavable.

Protection filter Interchangeable hydrophobic membranefilter guarantees effective protection against airborne contamination during aspiration and dispensing.

ProfillerTMmanual 435

Product advantages

Large capacity bulbSoft action lever buttonEfficient blow-out systemPTFE protection membrane filterMaintenance freeAlternative colour-coded nose cones

The ProfilletteTM 406

Product advantages

One-hand operationEasy filling and dispensingAir inlet valve for fast distributionColour coding per sizeMaintenance free

Robust and easy to use, this model offers ergonomic shape and light weight. It provides smooth control in both, aspirating and dispensing, using glass or plastic pipettes of volume up to 100 mL.One-year warranty.

435Pipettes

up to 100 mL

Ordering information

Profillette™ 406

Ordering information

Profiller™ 435

Description Packaging Cat. No.

1 / pk1 / pk

5 / pk5 / pk1 / pk3 / pk3 / pk

1.406.011.406.02

322.435322.4001.435.011.435.021.435.03

Profillette™ 406

Spare silicone pipette holderReplacement nose screwProfiller™ 435

Membrane filter, 0.45μmMembrane filter, 0.2μmSilicone pipette holderNose cone - whiteAlternative nose cones - pink, violet, green (1 each)

Description Packaging Cat. No.

1 / pk 435.100ProfillerTM 435,egg style grey bulb

manual

1

41

2

3

2 5

3

4 5

manual pipette controllerProfi ller™manual

31

4062 mL

10 mL25 mL

Volumes Colours Packaging Cat. No.

1 / pk1 / pk1 / pk

3 / pack

bluegreenred

assorted

406.002406.010406.025406.300

2 mL10 mL25 mL2 / 10 / 25 mL

Page 33: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

Ordering information - pipette tip selection

32

www.socorex.com

A perfect match between micropipettes and tips guaranteestrouble-free pipetting and reliable results. The Socorex Qualitips® are designed to fulfil above preconditions. The line is exclusively made from high grade, virgin, metal-free polypropylene. Precision injection moulding care for air-tight fit. Stringent quality procedures ensure lot by lot consistency.Various shapes in a range from 10 μL to 10 mL.

SizeCat. No.

70.9 mm

42.3 mm

31.0 mm

31.0 mm

302.0010GR

302.0020R

302.0020B

309.0010FR

309.0010R

309.0010B

45.6 mm302.0010FR302.0010AFB

Qualitips 10 μL

Qualitips 20 μL

Qualitips 100 μL

54.1 mm308.0100FR

69.0 mm308.0100GFR

SizeCat. No.Description

51.0 mm 308.0020FR

69.0 mm308.0020GFR

308.0020FS

SizeCat. No.Description

DescriptionFilterCapacityTip also fits Colour Style Unit Quantity

10 μL

10 μL

10 μL

10 μL

10 μL

10 μLBT, EP, GL

BT, EP, GL

Natural

Natural

Natural

Natural

Natural

Natural

No

No

No

Yes

No

No

No

No

No

Yes

No

No

Rack

Rack

Bag

Rack

Rack

Bag

4 x 204

10 x 96

1000

10 x 96

10 x 96

1000

Gel loading

Micro

10 μL10 μL

BR, EP, TF

BR, BT, EP

BR, BT, EP

BR, BT, EP,TF, GL

BR, EP, TFBR, EP, TF

NaturalNatural

YesYes

YesNo

RackBag

10 x 1001000

MicroMicro

Micro

Ultra-micro

Ultra-micro

Ultra-micro

SterilizedPackaging

100 μL Natural Yes Yes Rack 10 x 96Regular

100 μL Natural Yes Yes Rack 4 x 204Gel loading

FilterCapacityTip also fits Colour Style Unit QuantitySterilizedPackaging

20 μL Natural Yes Yes Rack 10 x 96Regular

20 μL Natural Yes Yes Rack 4 x 204Gel loading

20 μLBR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

Natural Yes YesBag, single wrapped

5 x 100Regular

FilterCapacityTip also fits Colour Style Unit QuantitySterilizedPackaging

The Qualitips® pipette tips

from 10 μL to 10 mL

Product advantages

Wide selection, superior qualityLot-by-lot consistencyBulk or rack availabilityCompatibility with various pipette brandsHigh-density filter prevents aerosol contaminationDNAse and RNAse-free filter tipsPyrogen-free sterilized filter tips

Ask for free samples

pipette tipsQualitips®

Page 34: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

33

Size QuantityCat. No.

308.0200R

308.0200B

307.0200B

327.0200R

327.0200B

328.0200R

328.0200B

309.0200R

309.0200B

308.0200GR

308.0200LFS

308.0200LFR

329.0200R

329.0200B

BR, BT, EP, TF

Qualitips 200 μL

SizeCat. No.

BR, BT, EP, GL

BR, BT, EP, GL

308.0350R

308.0350B

BR, BT, EP, GL

BR, BT, EP, GL

308.0300AFB

308.0300FR

Qualitips 300 / 350 μL

Size UnitCat. No.

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

307.1000R

307.1000B

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

309.1000R

309.1000B

Qualitips 1000 μL

BR, BT, EP, TF

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

319.1000R

319.1000B

BR, BT, EP, TF

51.1 mm

49.4 mm

49.4 mm

49.0 mm

49.7 mm

69.0 mm

90.9 mm

49.7 mm

88.6 mm

58.8 mm

58.8 mm

79.0mm

72.0 mm

72.0 mm

69.5 mm

BR, BT, EP, TF

318.1000R

318.1000B

FilterCapacityTip also fits Colour Style Unit

200 μL

200 μL

200 μL

Natural

Natural

Natural

No

No

No

No

No

No

Rack

Bag

Bag

10 x 96

1000

2 x 500

Regular

Regular

Graduated

200 μL

200 μL

Yellow

Yellow

No

No

No

No

Rack1)

Bag

10 x 96

2 x 500

Graduated

Graduated

200 μL

200 μL

200 μL

200 μL

Yellow

Yellow

Natural

Natural

No

No

No

No

No

No

No

No

Rack

Bag

Rack

Bag

10 x 96

2 x 500

10 x 96

2 x 500

Regular

200 μL Natural No No Rack 4 x 204Gel loading

200 μL

200 μL

Natural

Natural

Yes

Yes

Yes

Yes

Bag, single wrapped

Rack

5 x 100

8 x 204

Extended

Extended

Regular

Regular

Regular

200 μL

200 μL

Yellow

Yellow

No

No

No

No

Rack

Bag

10 x 96

2 x 500

Regular

Regular

Sterilized

Natural

Natural

Natural

Yes

Yes

Yes

Yes

Yes

No

Rack

Bag

Regular

Regular

Regular

Packaging

FilterCapacity Colour Style Unit Quantity

350 μL

350 μL

Natural

Natural

No

No

No

No

Rack

Bag

10 x 96

1000

Regular

Regular

300 μL

300 μL

Natural

Natural

Yes

Yes

No

Yes

Bag

Rack

1000

10 x 96

Regular

Regular

SterilizedPackaging

FilterCapacity

Tip also fits

Tip also fits Colour Style Quantity

1000 μL

1000 μL

Natural

Natural

No

No

No

No

Rack1)

Bag

10 x 60

4 x 250

Graduated

Graduated

1000 μL

1000 μL

Natural

Natural

No

No

No

No

Rack

Bag

8 x 60

4 x 250

Regular

Regular

SterilizedPackaging

1000 μL

1000 μL

Blue

Blue

No

No

No

No

Rack

Bag

8 x 60

4 x 250

Regular

Regular

1000 μL

1000 μL

Blue

Blue

No

No

No

No

Rack

Bag

8 x 60

4 x 250

Regular

Regular

Description

Description

Description

Tip also fitsCat. No.

Description Cat. No.PackagingLid typeFitting

F

E

312.10

312.02

G

150.0 mm

115.5 mm

123.2 mm

G

312.05R

312.05B

Qualitips 2 / 5 / 10 mLFilterCapacity Colour Style Unit Quantity

10 mL

2 mL

Natural

Natural

No

No

No

No

Bag

Bag

3 x 100

2 x 250

Regular

Regular

5 mL

5 mL

Natural

Natural

No

No

No

No

Rack

Bag

2 x 50

2 x 250

Graduated

Graduated

SterilizedPackagingDescription

Size

Empty autoclaving boxes

Tip fitting: BR = Brand®, BT = Biohit®, EP = Eppendorf®, FP = Finnpipette®, GL = Gilson®. Brand names belong to their respective owners.

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, EP

BR, EP

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, BT, EP, TF, GL

BR, BT, EP, TF 309.1000FS

309.1000FR

309.1000AFB

1000 μL

1000 μL

1000 μL

5x 100

10 x 100

1000

Bag, singlewrapped

Empty boxEmpty boxEmpty boxEmpty boxEmpty boxEmpty box

10 μL tips #309.0010B10 μL tips #302.0020B

200 μL tips #328.0200B350 μL tips #308.0350B1000 μL tips #319.1000B

10 mL tips #312.10

hingedcovercovercovercover

hinged

10 / pk10 / pk10 / pk10 / pk8 / pk4 / pk

309.0010ER302.0020ER328.0200ER308.0350ER319.1000ER312.10ER

pipette tipsQualitips®

Page 35: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

www.socorex.com

34

309.0010B + R

309.0010FR

302.0020B + R

302.0010FR + AFB

302.0010GR

307.1000B + R

309.1000B + R

319.1000B + R

318.1000B + R

309.1000FR + FS + AFB

308.0020FS + FR

308.0020GFR

up to 1

0 μ

L

10 Y

/ 15 /

20 μ

L

25 to 1

00 μ

L

120 to 2

00 μ

L

250 to 1

000 μ

L

0.1

– 2

μL

0.5

– 1

0 μ

L

1 –

10 μ

L (Y

)

2 –

20 μ

L

5 –

50 μ

L

10 –

100 μ

L

20 –

200 μ

L

100 –

1000 μ

L

0.2

– 2

mL

0.5

– 5

mL

1 –

10 m

L

0.5

– 1

0 μ

L

5 –

50 μ

L

20 –

200 μ

L

40 –

350 μ

L

0.2

– 2

μL

1 –

10 μ

L

1 –

10 μ

L (Y

)

2 –

20 μ

L

10 –

100 μ

L

20 –

200 μ

L

100 –

1000 μ

L

0.2

– 2

mL

1 –

10 m

L

1 –

10 μ

L

10 –

100 μ

L

20 –

200 μ

L

Acura® manual and Acura® electro Calibra® digital

815 825/826/925/926 835/935/936 832 852855/955/956 822

Microtips, 20 μL

Microtips, 100 μL

308.0100FR

308.0100GFR

307.0200B

327.0200B + R

308.0200B + R

309.0200B + R

329.0200B + R

328.0200B + R

308.0200GR

308.0200LFS + LFR

308.0350B + R

308.0300FR + AFB

312.02 (2 mL)

312.05B + R (5 mL)

312.10 (10 mL)1) Only to max. volume of the tip 2) As of serial number 09091001 3) > 2 μL only

Microtips, 200 μL

Microtips, 300 / 350 μL

Microtips, 1000 μL

Microtips, 10 μL

Macrotips

x x x

x

x

xx

x

x

x

x x x x

x x

x x

x

x

x

x

x

x xx x x x xx x xx

x xx

x x xx

x x xx

x x xx

x x xx

xx

xx

xx

xx

x x x

x

x

xx

xx

xx

xx

xx

x x x xx

x x x xx

x x x x

x

x

x x x

x x

x

xx

x x xx

x xx

x xx

x x

x

x

x

xx

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

xx

x

x

xx

x

x

x

x

x x x

x

x x

x

x

x

x x

x

x

x

x x x

x

x

x

x

x

x

x3)

x3)

x1)

x1)

x1) x x1)

x1)

x1) x1)x1)

x1)

x1) x x1)

x1)x1)

x2)

x2)

x2)

x2)

x3)

Qualitips® compatibility chartChart below indicates optimal combination of Qualitips® and Socorex® pipette. Detailed compatibility with other pipette brands available on request. Please contact your local distributor or Socorex.

Page 36: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

35

consumablesQualitips®

Straw tipsFitting the Acura® 810 dilution pipette, the long and thin shape straw tips allow pick-up of particle containing liquids in Stomacher® bags and deep, narrow reservoirs without blocking. Supplied sterilized in re-sealable bag.

Pasteur pipette adaptersDedicated PVDF adapters with two internal O-rings tightly fitting glass Pasteur pipette (ext Ø 6.5 – 7.2 mm), without excluding the use of regular PP tips.

Material

Glass

Glass with cotton plug

Fits macropipette

Acura® manual 835, 2 mL Calibra® digital 832, 2 mLAcura® manual 835, 5 mLAcura® electro 936, 5 mL

2 mL

2 mL

Volume

150 x 7230 x 7150 x 7230 x 7

Dimension (lxØ mm)

250/ pk250/ pk250/ pk250/ pk

Packaging

313.02.150313.02.230313.02.150C313.02.230C

Cat. No.

1.835.631

1.835.633

Cat. No.

1/ pk

1/ pk

Packaging

Description

Straw tips, 1.1 mL

Nozzle filterNozzle filterNozzle filter

Nozzle filter

Fits

Acura® manual 810

Acura® manual 810Calibra® digital 832, 2 mL

Acura® manual 835, 2 and 5 mLAcura® electro 935, 5 mL

Calibra® digital 832, 10 mLAcura® electro 935, 10 mL

Material

PP, sterilized

PECellulosePP fibre

PP fibre

Size (lxØ mm)

190 x 4

6.3 x 2.522 x 7

20 x 7.5

30 x 10.5

Packaging

40x 25/ pk

100/ pack250/ bag250/ bag

100/ bag

Cat. No.

313.1119.40

322.810322.02322.05

322.10

Glass Pasteur pipetteStandard 2 mL models fitting Acura® and Calibra® 2 and 5 mL macropipettes with their respective adapters. Useful alternative to macrotips, for instance when handling PP affecting reagents. Model and size selection fit most lab requirements.

5

5

6

6

2 3

3

Nozzle filters for pipettesProtection against liquid overflow or aerosol contamination. Filters are interchangeable, non-sterile, non autoclavable.

4

4

1

1 2

Ordering information - Pasteur pipettes Pasteur adapter

Ordering information - Straw tips and nozzle filters

Page 37: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

www.socorex.com

36

Multichannel reagent reservoirs8 and 12 channel reservoirs provide ideal solutions for many applications. Sterilized PS material, single wrapped.

Description

ReservoirReservoirReservoirReservoir

58x132x25 mm83x121x34 mm83x126x13 mm83x126x13 mm

Dimensions

70 mL125 mL48 mL48 mL

Volume

NaturalNaturalWhiteWhite

Colour

V-shapedV-shaped8-channel12-channel

Style

NoYes, hinged

NoNo

Lid

PPPPPSPS

Materials

NoNoYesYes

Sterilized

20/ pack20/ pack

10x 1/ pack10x 1/ pack

Packaging

330.01330.01L330.08.9330.12.9

Cat. No.

All-purpose reagent reservoirsParticularly well suited for single and multichannel pipetting. V-shape bottom enables aspiration until last reagent drops. Made of PP, autoclavable, re-usable.

2

2

3

3

1

1

Ordering information - Reagent reservoirs

Page 38: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

37

Holder for two instrumentsThe attractive design accommodates all Calibra® and Acura® instruments, including microdispenser pipettes Acura® 865. A self-adhesive strip supplied ensures lasting attachment on any clean surface. Made of polycarbonate material.

Extended compatibility Work station 340 also accommodates the dilution pipette Acura® 810 andthe microdispenser pipettes Acura® 865. Heavy bottom plate and anti-slip pads guarantee high stability. Madeof polyamide material.

Colour Packaging Cat. No.

1 / pk4 / pk

320.332320.332.4

Transparent blueTransparent blue

Shelf pipette holder 332

1 / pk 320.340Light grey3 pipette work station 340

Ordering information

340

1 32 4

work stationspipette

Shelf pipette holder 332

2-positionFitting micro, macro and multichannel pipettes

Static work station 340

3-positionFitting micro, macro and/or

multichannel Socorex pipettesEasy reach of each instrument

Properly storing micropipettes prevents damages and extends their life span. Socorex® offers a choice of stands adapted to any laboratory configuration.

332

1 32 4

Page 39: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

www.socorex.com

38

Universal storage solutionNo more micropipettes laying on the bench thanks to universal stands.They accommodate Socorex® andother brand micropipettes. Simpledisassembling and cleaning.

Smooth rotationStand includes mechanism enabling soft rotation with the fingertip.For quick selection and pickingof the desired micropipette.

Colour Packaging Cat. No.

1 / pk1 / pk1 / pk1 / pk1 / pk1 / pk1 / pk

320.336R320.336O320.336Y320.336G320.336B320.336Q320.336W

Rubin redTopaz orangeCitrine yellowEmerald greenSapphire blueQuartz greyDiamond white

1 / pk1 / pk1 / pk1 / pk1 / pk

320.337G320.337R320.337B320.337M320.337Y

Light greyPastel roseIce blueMint greenVanilla yellow

TwisterTM universal 336

In-line universal 337

Ordering information In-line universalityOne fits all; the stand holds newand old generations of Socorex®and other brand micropipettes.

337

1

1

2

2 3

3

4

4

TwisterTM universal 336

6-position360° soft rotationInstruments easy to fetchConcept fits pipettes of most brandsInterchangeable discsSeven translucent colours

In-lineTM universal 337

7-positionHolds single channel pipettes

of most brandsSpace saving pipette standSturdy polyamide materialFive attractive pastel colours

The two universal micropipette stands fit all brands, ensuringtheir proper storage at any time. Anti-slip pads guarantee bench stability. Easy to clean.

336

Page 40: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

39

Broad calibration programmeWhatever the maintenance level needed for micropipettes and dispensers, Socorex has the appropriate answer, including customised service plans when required.

Efficient handlingThe lead time for instruments received at Socorex is three to five working day, or 48 hours using our “Express service”.

Service Center on the webFor more details about our service pro-gramme, check: www.socorex.com

Personalised technical supportHighly qualified personnel with a broad product knowledge is at disposal for all technical matters. The team also provides professional answers and solutions about handling, maintenance and control procedures.

SCS laboratory Accredited by SAS (Swiss Accreditation Services) of the Federal Office of Metrology, the Socorex QC laboratory performs calibrations in full compliance with ISO 17025 and delivers control certificates recognised internationallyby ILAC members.

Examples of ILAC members

from signatory countries

Advantages

Know-how and high competenceAll brand service for pipettes and dispensersBroad programmeControls according to ISO 8655 and ISO 17025 standardsSAS accredited QC laboratory

Socorex instruments are built to last. In order to guarantee trouble free usage over time, a minimum maintenance and regular calibration are strongly recommended. From rapid check-up or basic repair to GLP requirements, the Socorex Service Center - in its ultra-modern facilities - provides fast and reliable service and calibration, based on a long term experience in manufacturing precision liquid handling instruments.

OrganisationCountry

AustraliaAustriaBelgiumBrazil

CanadaChina

China HKCroatia

Czech RepublicDenmarkFinlandFrance

GermanyHungary

IndiaIndonesia

IrelandItaly

JapanNetherlands

NorwayPoland

PortugalSouth Africa

SloveniaSpain

SwedenSwitzerland

TurkeyUnited Kingdom

USA

NATABMWABELAC

CGCRE / INMETROSCC-CLAS

CNASHKASHAACAI

DANAKFINAS

COFRACDAkkSNATNABLKANINABSIT

IA-JAPANRvANAPCAIPAC

SANASSA

ENACSWEDAC

SASTURKAK

UKASNVLAP

Complete list and details under www.ILAC.org

service programmeSocorex Service Center

Page 41: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

www.socorex.com

40

Procedures

Service levels Maintenance and control per ISO 8655

StandardCheck-up

•• • • • • • • •

•• • • •

10 x5 x

5 x

5 x

10 x

10 x 3)

10 x 10 x

10 x 10 x

10 x 3)

10 x 10 x

10 x

10 x 3)

10 x

10 x

10 x 3)

10 x

ISO 17025

10 x

10 x 3)

10 x

10 x

10 x

10 x 10 x

10 x 3)

10 x

4 x 2)

4 x 2) 10 x

10 x

10 x 3)

10 x

• • • •

• • • •

-

-

--

• • • •

• • • • • • • •

• • • • • • • •

•• • • • • • • •

••

• • • •

• •

• • •

• • • • •

• • • •

Classic Premium Advanced UltraUltraSCS

Newinstruments

2) Five measurements, multichannel below 50μL 3) When applicable1) On request

Instrument registration

Gravimetric test beforemaintenance (“as found”)

Decontamination 1), disinfection,disassembling, cleaning

Instrument check-up

X-ring replacement as needed

Other faulty parts replacement as needed

Function and tightness check

Gravimetric test aftermaintenance per ISO 8655

Gravimetric test after maintenance per ISO 17025

Final check and visa

QC certificate before maintenance (“as found”)

QC certificate after calibration (“as left”)

Accredited certificate per ISO 17025

Min. vol.

Min. vol.

Mid. vol.

Mid. vol.

Max. vol.

Mid. vol.

Max. vol.

Min. vol.

Max. vol.

Classic SCS

Premium SCS

Accredited calibration per ISO 17025

Accreditedcertificate

to beordered

withinstrument

Service programme

Standard serviceRepair, maintenance, control and calibration, 2x4 measurements, with QC certificate.

The cost-effective solutionfor any liquid handling instrument.

Check-upControl, 3x 5 measurements,

with detailed certificate before main-tenance («as found»).

Adequate for rapid instrument evaluation.

Classic serviceCleaning and maintenance,

control and calibration, 2x 10 measurements,

with detailed QC certificate.

Recommended as routine check.

Classic SCS serviceSame as above, but withISO 17025 calibration and SCS accredited certificate.

Alternative routine check when dealing with ISO 17025 pro-

cedures, or when mastering uncertainties

is required.Ultra SCS service

Same as above with ISO 17025 calibration and SCS accredited certificate.

Ultimate service when dealing with ISO 17025 for GLP environ-ment demanding analytical results.

Premium SCS service

Same as above, but with ISO 17025 calibration andSCS accredited certificate.

A must for laboratories dealing with ISO 17025 procedures, or

when mastering uncertainties is required. Available for new

instruments as well.

Premium service

Cleaning and maintenance, control and calibration, 3x10 mea-

surements, with detailed QC certificate.

An in-depth check, also including mid-range measurements.

A choice of service levels

Advanced serviceControl, 2x10 measurements, with

detailed certificate before maintenance (“as found”). Then cleaning, maintenance and calibration,

2x10 measurements, with detailed QC certificate.

Perfect for instruments used in GLP environments or for validation of critical analytical results.

Ultra serviceControl, 3x 10 measurements, with detailed certificate

before maintenance (“as found”). Then cleaning, mainte-nance and calibration, 3x10 measurements,

with detailed QC certificate.

Ultimate service for GLP environment when analytical results are demanded.

Page 42: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

Cat. No. Page

0187.003 29

0187.005 29

0187.01 29

0187.02 29

0187.05 29

0187.05T 28

0187.10 29

0187.20 29

1.170.054 18/28

1.170.058 18/28

1.170.205 28

1.170.300 28

1.170.301 28

1.170.305 28

1.170.320 28

1.170.4005 29

1.170.401 29

1.170.402 29

1.170.405 29

1.170.410 29

1.170.420 29

1.170.705 28

1.170.906 28

1.170.912 28

1.170.945 28

1.170.952 28

1.187.060 28

1.187.150 28

1.187.1C 28

1.187.250 28

1.187.72003 29

1.187.72005 29

1.187.7201 29

1.187.7202 29

1.187.7205 29

1.187.7210 29

1.187.7220 29

1.406.01 31

1.406.02 31

1.411.7 17

1.435.01 30/31

1.435.02 30/31

1.435.03 30/31

1.524 23

1.525.120 23

1.525.121 23

1.525.150 23

1.525.151 23

1.525.525 24

1.525.526 24

1.525.546 23

1.525.581 23

1.525.625 23

1.525.650 23

1.525.GL32 24

1.525.GL38 24

Cat. No. Page

1.525.GL40 24

1.825.025 8

1.825.100 8

1.825.700 9

1.825.710 9

1.825.711 9

1.825.712 9

1.825.713 9

1.825.714 9

1.825.715 9

1.825.716 9

1.825.717 9

1.825.718 9

1.825.719 9

1.825.720 9

1.825.721 9

1.825.722 9

1.825.723 9

1.831.707 6

1.835.631 6/35

1.835.633 6/35

1.861.21T 18

1.861.631 18

1.861.720 18

1.861.925 18

1.861.E32 18

155.0301 29

155.0305 29

155.0310 29

155.03100 29

155.0320 29

155.0330 29

155.0501 29

155.0502 29

155.0505 29

155.0510 29

155.05100 29

155.05150 29

155.0520 29

155.05200 29

155.05250 29

155.0530 29

155.0550 29

162.0501 27

162.0502 27

162.0505 27

163.05003 27

163.05005 27

163.0501 27

163.0502 27

163.0505 27

163.0510 27

164.0501 27

164.0502 27

164.0505 27

164.0510 27

Cat. No. Page

172.0501 27

172.0502 27

172.0505 27

172.0510 27

173.05003 27

173.05005 27

173.0501 27

173.0502 27

173.0505 27

173.0510 27

173.0520 27

174.0501 27

174.0502 27

174.0505 27

174.0510 27

187.591 29

187.592 29

187.593 29

187.594 29

187.705 29

187.707 29

187.710 29

187.905 29

187.910 29

187.933 29

302.0010AFB 32

302.0010FR 32

302.0010GR 32

302.0020B 32

302.0020ER 33

302.0020R 32

307.0200B 33

307.1000B 33

307.1000R 33

308.0020FR 32

308.0020FS 32

308.0020GFR 32

308.0100FR 32

308.0100GFR 32

308.0200B 33

308.0200GR 33

308.0200LFR 33

308.0200LFS 33

308.0200R 33

308.0300AFB 33

308.0300FR 33

308.0350B 33

308.0350ER 33

308.0350R 33

309.0010B 32

309.0010ER 33

309.0010FR 32

309.0010R 32

309.0200B 33

309.0200R 33

309.1000AFB 33

Cat. No. Page

309.1000B 33

309.1000FR 33

309.1000R 33

309.100FS 33

312.02 33

312.05B 33

312.05R 33

312.10 33

312.10ER 33

313.02.150 35

313.02.150C 35

313.02.230 35

313.02.230C 35

313.1119.40 13/35

314.0100 24

314.0250 24

314.0250C 24

314.0500 24

314.0500C 24

314.0500P 24

314.0500PE 24

314.1000 24

314.1000C 24

314.1000PE 24

314.2000C 24

314.2500 24

314.2500H 24

314.2500PE 24

315.0250 24

315.0500 24

315.1000 24

315.2500 24

316.010 17

316.010.9 17

316.050 17

316.050.9 17

316.500 17

316.500.9 17

318. 1000B 33

318. 1000R 33

319. 1000B 33

319. 1000R 33

319.1000ER 33

320.332 13/37

320.332.4 13/37

320.333 16

320.336B 38

320.336G 38

320.336O 38

320.336Q 38

320.336R 38

320.336W 38

320.336Y 38

320.337B 38

320.337G 38

320.337M 38

Cat. No. Page

320.337R 38

320.337Y 38

320.340 13/18/37

320.411 17

320.446 30

320.903.48 6

320.913.48 6

320.BC050 23

320.BC100 23

320.SB050 23

320.SB100 23

322.02 35

322.05 6/35

322.10 6/35

322.400 30/31

322.435 30/31

322.810 13/35

327.0200B 33

327.0200R 33

328.0200B 33

328.0200ER 33

328.0200R 33

329.0200B 33

329.0200R 33

330.01 36

330.01L 36

330.08.9 36

330.12.9 36

341.005 16

341.025 16

341.050 16

341.100 16

341.200 16

342.005 16

342.025 16

342.050 16

342.100 16

342.200 16

370.0840 28

370.1250 28

370.22100 28

370.22150 28

370.30180 28

370.30500 28

371.0713 28

371.0810 28

371.0825 28

371.0830 28

371.0840 28

371.1010 28

371.1020 28

371.1030 28

371.1040 28

371.1210 28

371.1210UN 28

371.1220 28

Cat. No. Page

371.1235 28

371.1250 28

371.1420 28

371.1435 28

371.15150 28

371.16100 28

371.1620 28

371.1620UN 28

371.1625 28

371.1630 28

371.1810 28

371.1820 28

371.1830 28

371.2030 28

371.2030UN 28

371.2040 28

371.2050 28

376.0925B 28

376.0925S 28

376.1251B 28

376.1251S 28

376.16102B 28

376.16102S 28

376.30203B 28

376.30203S 28

406.002 31

406.025 31

406.010 31

406.300 31

411.5000 17

435.100 31

446.100E 30

446.100G 30

446.100U 30

501.02025 19

501.021 19

501.022 19

501.0505 19

501.051 19

501.052 19

501.101 19

501.102 19

501.302 19

511.707 24

511.709 24

520.002 20

520.005 20

520.010 20

520.F02 20

520.F05 20

520.F10 20

521.621 24

521.622 24

521.623 24

521.705 24

521.706 24

catalogue number indexProduct references

Page 43: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

Cat. No. Page

525.025 22

525.025FC 22

525.050 22

525.050FC 22

525.100 22

525.100FC 22

525.350 24

525.706 24

530.025 22

530.025FC 22

530.050 22

530.050FC 22

530.100 22

530.100FC 22

800.0002 6

800.0002XS 6

800.0010 6

800.0010XS 6

800.0010Y 6

800.0010YXS 6

800.0020 6

800.0020XS 6

800.0050 6

800.0050XS 6

800.0100 6

800.0100XS 6

800.0200 6

800.0200XS 6

800.08.010 6

800.08.050 6

800.08.200 6

800.08.350 6

800.1000 6

Cat. No. Page

800.10000 6

800.1000XS 6

800.12.010 6

800.12.050 6

800.12.200 6

800.12.350 6

800.2000 6

800.5000 6

810.1100 13

815.0001 11

815.0005 11

815.0010 11

815.0010Y 11

815.0015 11

815.0020 11

815.0025 11

815.0030 11

815.0032 11

815.0040 11

815.0050 11

815.0060 11

815.0070 11

815.0075 11

815.0080 11

815.0090 11

815.0100 11

815.0120 11

815.0150 11

815.0200 11

815.0250 11

815.0300 11

815.0400 11

815.0500 11

Cat. No. Page

815.0600 11

815.0700 11

815.0750 11

815.0800 11

815.0900 11

815.1000 11

822.0002 14

822.0010 14

822.0010Y 14

822.0020 14

822.0100 14

822.0200 14

822.1000 14

825.0002 8

825.0010 8

825.0010Y 8

825.0020 8

825.0050 8

825.0100 8

825.0200 8

825.1000 8

825.TRIO.C 9

825.TRIO.J 9

825.TRIO.M 9

825.TRIO.O 9

825.TRIO.P 9

825.TRIO.S 9

825.TRIO.T 9

825.TRIO.V 9

826.0002 8

826.0010 8

826.0010Y 8

826.0020 8

Cat. No. Page

826.0050 8

826.0100 8

826.0200 8

826.1000 8

826.TWX.E 9

826.TWX.G 9

826.TWX.H 9

826.TWX.K 9

826.TWX.N 9

826.TWX.Q 9

832.02 14

832.10 14

835.02 10

835.05 10

835.02PP 10

835.05PP 10

835.10 10

835.F02 11

835.F02.5 11

835.F05 11

835.F10 11

835.TRIO.Y 9

841.005 16

841.025 16

841.050 16

841.100 16

841.200 16

852.08.010 15

852.08.100 15

852.08.200 15

852.12.100 15

852.12.200 15

855.08.010 12

Cat. No. Page

855.08.050 12

855.08.200 12

855.08.350 12

855.12.010 12

855.12.050 12

855.12.200 12

855.12.350 12

865.0050 18

865.0200 18

865.1000 18

900.901.48A 6

900.901.48E 6

900.901.48G 6

900.901.48U 6

900.916 30

900.920.48 6

900.922.48 6

900.946E 30

900.946G 30

900.946U 30

926.0002 6

926.0002E 6

926.0010 6

926.0010E 6

926.0010Y 6

926.0010YE 6

926.0020 6

926.0020E 6

926.0050 6

926.0050E 6

926.0100 6

926.0100E 6

926.0200 6

Cat. No. Page

926.0200E 6

926.1000 6

926.1000E 6

936.02 6

936.02E 6

936.05 6

936.05E 6

936.10 6

936.10E 6

956.08.010 6

956.08.010E 6

956.08.050 6

956.08.050E 6

956.08.200 6

956.08.200E 6

956.08.350 6

956.08.350E 6

956.12.010 6

956.12.010E 6

956.12.050 6

956.12.050E 6

956.12.200 6

956.12.200E 6

956.12.350 6

956.12.350E 6

GLP + Ø 24

GLT + Ø 24

NSP + Ø 24

NST + Ø 24

Notes

www.socorex.com

Page 44: CGEN EN 2014 - pipete.ltyour quality partner worldwide precision volumetry Electronic micropipettes Positive displacement pipettes Digital setting micropipettes Repeater pipette

SOCOREX ISBA SA

Champ-Colomb 7, P.O. Box

1024 Ecublens/Lausanne

Switzerland

[email protected]

www.socorex.com

Tel. +41 (0)21 651 6000

Fax +41 (0)21 651 6001

C.G

EN.E

– E

913

Your local distributor

Important information

Refer to package inserts for safety precautions, operating instructions and warranty terms.

User must pay special attentionto possible hand fatigue during serial pipetting and its medical consequences such as repetitive strain injuries (RSI).

Mind risks involved in handling hazardous liquids with respect to personal, third party andenvironmental protection and safety.

Products and specifications are subject to change without prior notice.

Copyright © 2013 by Socorex Isba SA, Switzerland