cf-18,cf-25,cf-35, cf-40, cf-50, cf-50dz, cf-60 .–2 (cf-50dz only) internal compartment divider

Download CF-18,CF-25,CF-35, CF-40, CF-50, CF-50DZ, CF-60 .–2 (CF-50DZ only) Internal compartment divider

Post on 04-Jun-2018

223 views

Category:

Documents

0 download

Embed Size (px)

TRANSCRIPT

  • M_100902

    CF-18,CF-25,CF-35, CF-40,CF-50, CF-50DZ, CF-60

    AUS Compressor Cooler Instruction Manual

    CF-40 AC

    CF-50 AC

    CF-50 ACDZ

    CF-60 AC

    CF-25CF-18

    CF-35 AC

    CF18-60_M_100902:PowerVac_PV-100 17/8/10 3:28 PM Page 1

  • 3

    CoolFreeze

    Please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is handed over toanother person, this operating manual must be handed over along with thedevice.

    Contents1 Notes on using the manual ...................................................... 72 Safety instructions ........................................................................ 7

    2.1 General safety ................................................................................ 82.2 Operating the device safely .......................................................... 9

    3 Scope of delivery ........................................................................... 104 Intended use .................................................................................... 105 Function description ..................................................................... 11

    5.1 Operating and display elements ................................................... 125.2 Accessories ...................................................................................... 14

    6 Operation ........................................................................................... 146.1 Before initial use ............................................................................ 146.2 Energy saving tips .......................................................................... 156.3 Connecting the cooler .................................................................... 166.4 Using the battery monitor ............................................................. 176.5 Using the cooler ............................................................................. 186.6 Setting the temperature ................................................................ 196.7 Using the Emergency Switch ......................................................... 206.8 Switching off the cooler ................................................................. 206.9 Defrosting the cooler ...................................................................... 206.10 Replacing the device fuse (240V) ................................................. 216.11 Replacing the plug fuse (12/24 V) ............................................... 216.12 Replacing the light bulb ................................................................. 22

    7 Cleaning and maintenance ........................................................228 Warranty ........................................................................................... 229 Troubleshooting ...............................................................................2310 Disposal ............................................................................................... 2411 Technical data .................................................................................. 24

    CF18-60_M_100902:PowerVac_PV-100 17/8/10 3:28 PM Page 3

  • 4

    CoolFreeze

    1

    4

    2

    3

    1

    12/24V DC

    COLD FREEZE

    ERROR

    POWER

    HIGH

    0

    LOW

    TEMPERATURE BATTERY MONITOR

    1 2 3 4

    5

    1

    2

    3

    CF-25, CF-35, CF-40,

    CF-18

    CF18-60_M_100902:PowerVac_PV-100 17/8/10 3:28 PM Page 4

  • 5

    CoolFreeze

    ONOFF

    SET

    POWER

    UP+

    DOWN

    ERROR

    1 3 4 5 6 72

    1

    2 1

    4

    7

    12/24V DC

    145

    CF-25, CF-35, CF-40, CF-50, CF-60

    CF-35, CF-40, CF-50, CF-60CF-25

    CF-35, CF-40, CF-50, CF-60

    100-240V~AC

    FUSE

    EMERGENCY OVERRIDE

    NORMAL USE

    1 2

    12/24V DC

    346

    CF18-60_M_100902:PowerVac_PV-100 17/8/10 3:28 PM Page 5

  • 6

    CoolFreeze

    8

    1 2 3

    4

    5

    6

    9 1 210

    CF-50, CF-60

    A B

    CF18-60_M_100902:PowerVac_PV-100 17/8/10 3:28 PM Page 6

  • 7

    CoolFreezeNotes on using the manual

    1 Notes on using the manualThe following symbols are used in this operating manual:

    Caution!Safety instruction: Failure to observe this instruction can cause personalinjury or damage the device.

    Caution!Safety instruction: relating to a danger from an electrical current orvoltage. Failure to observe this instruction can cause injury or damagethe device and impair its function.

    Note:Supplementary information for operating the device.

    Action: This symbol indicates that action is required on your part. The required action is described step-by-step.

    This symbol indicates the result of an action.Fig. 2 1, page 3: This refers to an element in an illustration. In thiscase, item 1 in figure 2 on page 3.Please observe the following safety instructions.

    2 Safety instructions

    Caution!WAECO International will not be held liable for claims for damageresulting from the following: Damage to the device resulting from mechanical influences and

    overvoltage Alterations to the device made without the explicit permission of

    WAECO International Use for purposes other than those described in the operating manual.

    CF18-60_M_100902:PowerVac_PV-100 17/8/10 3:28 PM Page 7

  • 8

    CoolFreeze Safety Instructions

    2.1 General safety

    Caution Danger of electrocution! When using the device on boats: If the device is powered by the

    mains, ensure that the power supply is protected with a ground fault interrupter circuit.

    Check that the voltage specification on the type plate corresponds tothat of the energy supply.

    Only connect the device as follows: With the cable supplied (Fig. 1 2, page 4) to the cigarette lighter

    in the vehicle or to a 12/24 V plug socket in the vehicle or with the enclosed connection cable (Fig. 1 3, page 4) to the

    100-240 V AC mains (only CF-35, CF-40, CF-50, CF-60). If the connection cable is damaged, it must be replaced to prevent

    possible electrical hazards. Do not pull the plug out of the cigarette lighter or the socket by the

    cable. Pull out the connection cable:

    Before cleaning and maintenance After use Before changing a fuse

    Disconnect the cooling device and other power consuming devicesfrom the battery before you connect the battery to a quick chargingdevice. Overvoltage can damage the electronics of the device.

    Electronic devices are not toys!Always keep and use the device out of the reach of children.

    Do not operate the device if it is visibly damaged. This device may only be repaired by qualified personnel. Inadequate

    repairs can lead to considerable hazards. Should your device need to be repaired, please contact WAECO

    customer service. Do not open the refrigerant circuit under any circumstances! The cooler is not suitable for transporting caustic materials or

    materials containing solvents. Food may only be stored in its original packaging or in suitable

    containers.

    CF18-60_M_100902:PowerVac_PV-100 17/8/10 3:28 PM Page 8

  • 9

    CoolFreezeIntended use

    2.2 Operating the device safely

    Caution Danger of electrocution!Do not touch exposed cables with your bare hands. This especiallyapplies when operating the device from an AC mains.

    Before starting the device, ensure that the power supply line and theplug are dry.

    Do not place any electrical devices inside the cooler. Set up the device in a dry location where it is protected against

    splashing water. Protect the device and the cable against rain and moisture. Do not place the device near naked flames or other heat sources

    (heaters, direct sunlight, gas ovens etc.)

    Caution! Danger of overheating!Ensure at all times that there is sufficient ventilation so that the heatgenerated during normal operation is able to dissipate. Ensure thatthe ventilation slots are not covered. Make sure that the device issufficiently far away from walls and other objects so that the air cancirculate.

    Never immerse the device in water. Do not fill the inner container with ice or fluid.

    CF18-60_M_100902:PowerVac_PV-100 17/8/10 3:28 PM Page 9

  • 10

    CoolFreeze Function description

    3 Scope of delivery

    Fig. 1 page 4, shows the scope of delivery.

    Item Quantity Description1 1 Cooler2 1 Connection cable for 12/24 VDC connection3 1 (except CF-18, CF-25) Connection cable for 100 240 VAC connection4 2 (except CF-18, CF-25) Carrying handle, consisting of:

    2 holders 1 handle 4 fastening screws

    1 (CF-18 only) Plastic grille divider 1 (CF-35 only) Powdercoated steel evap. protector 1 (except CF-18, Powdercoated steel basket

    CF-25, CF-50DZ)

    2 (CF-50DZ only) Powdercoated steel basket 2 (CF-50DZ only) Internal compartment divider (plastic) 1 Operating manual

    4 Intended use

    The cooler is suitable for cooling and freezing foods. The device is alsosuitable for use on boats.

    The device is designed to be operated from a 12 VDC or 24 VDC on-board supply socket of a vehicle (e. g. cigarette lighter), boat or caravanas well as from a 100 240 V AC mains (for CF-18 and CF-25 anoptional accessory adaptor is required for connection to AC mainspower).

    Caution When cooling perishable medicines!If you wish to cool medicines, please check if the cooling capacity of thedevice is adequate for this purpose.

    CF18-60_M_100902:PowerVac_PV-100 17/8/10 3:28 PM Page 10

  • 11

    CoolFreezeOperation

    5 Function descriptionThe cooler can chill products, keep them co