cetamine external presentation [mode de compatibilit ] · 6 12 cetamine v217 50% softened 50% ro...

19

Upload: phungtram

Post on 18-Aug-2018

235 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine
Page 2: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

Cetamine productsFilming Amines TechnologyFilming Amines Technology

For Boilers & Closed Systems

Page 3: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

�Formation of a monomolecular film, adsorbed onmetal surfaces all over the system; this aminefilm constitutes a continous barrier betweenwater and metal, cutting out corrosion without

CetamineFilming Amines Technology for Boiler Treatment

Cetamine is based on the combination of several actions :

3

water and metal, cutting out corrosion withoutaffecting the heat transfer

�Dispersion of scale forming salts

�pH control by means of neutralizing amines

Page 4: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

BOILERS

Cetamine includes a wide range of specific programs for :

CetamineFilming Amines Technology for Boiler Treatment

�High and low pressure boilers

�Boilers with turbines

�Boilout

4

CLOSEDWATER

SYSTEMS

�Wet conservation of boilers

�Industrial and district heating networks

�Heating systems

�Chilled water

�Closed cooling systems

With different types of make-up water qualities

Page 5: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

Cetamine is designed to protect the entire installation:

CetamineFilming Amines Technology for Boiler Treatment

WATER PREPARATION (e.g. SOFTENER) STEAM USE

RAW WATER

Prevention of corrosion and

5

BOILER

CONDENSER

DOSING TANK

CONDENSATE RETURN

FEEDTANK

BLOWDOWN

corrosion and deposits in

• Feedtank• Boiler• Steam pipes• Turbine• Condensate lines

Page 6: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

CetamineWhere is it used?

In any industry or plant with

Wide range of applications e.g.�Facility management

�Heating of sanitary water

�Laundries

6

�Boilers

�Closed systems

�Food Industry

�Plastic industry

�Metal-working & Automotive

�Chemical & Pharmaceutical

�Refineries

�Power Plants

Page 7: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

CetamineA complete range for specific applications

Examples of Cetamine products for BOILERSV210 industrial boilers fed with demineralized water

V211 high pressure boilers fed with demineralized water

V2000 low pressure boilers fed with softened water

V2100 high pressure boilers fed with demineralized water, with

7

V2100 high pressure boilers fed with demineralized water, with deposits

V217 Food industry

V212 For the conservation of boiler

Examples of Cetamine products for CLOSED SYSTEMSF300 Small & medium closed systems

F360 Closed systems containing Aluminium

F3100 Large closed systems

Page 8: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

CetamineExamples of boiler application

6 Cetamine V 217SoftenedShellESFood4

5 Cetamine V211SoftenedShellFRWaste

Incineration5

7 8 Cetamine V2000SoftenedShellESLaundry

5 3 Cetamine V211SoftenedShellFRHospital

BARS TN / HOUR

WATERBOILERCN PRODUCTINDUSTRY

LOW

PRESSURE

Date - Name - Title of presentation 8

10 15 Cetamine V217SoftenedShellESSlaughter

10 10 Cetamine V217RO waterClayton

Water tubeES

Pharmaceutical

6 12 Cetamine V21750% Softened50% RO water

ShellESChemical

15 3010% Softened90% Condens.

Shell Cetamine V 217FRTobacco

40 300 DemineralizedWater tube Cetamine V211IRRefinery

10 850% Softened50% Condens.

ShellFR Cetamine V 210Wood

60 100 DemineralizedShell &

water tubeCetamine V 210FRAutomotive

113 Cetamine V 211DemineralizedWater tubePTPower Plant150-330

HIGH

PRESSURE

Page 9: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

CetamineBenefits for your Boiler Treatment

COSTCOSTREDUCTIONREDUCTION

PROCESSPROCESSEFFICIENCYEFFICIENCY

9

HEALTH &HEALTH &ENVIRONMENTENVIRONMENT

SIMPLESIMPLEDOSINGDOSING

Page 10: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

CetamineBenefits for your Boiler Treatment

Cetamine does not increase the TDS level in the boiler, as

it is not a salt

10

Reduces blowdown and

hence energy and

water cost

COSTCOSTREDUCTIONREDUCTION

traditional Cetamine

Page 11: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

CetamineBenefits for your Boiler Treatment

Loosens and lifts existing scale

11

Better thermal transfer within the boiler,

leads to lower energy consumption

COSTCOSTREDUCTIONREDUCTION

PROCESSPROCESSEFFICIENCYEFFICIENCY

Page 12: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

CetamineBenefits for your Boiler Treatment

Enhances drop formation at heat exchange

surfaces

12

Improves heat transfer

and efficiency

in steam process applications

Film condensation

Drop condensation

PROCESSPROCESSEFFICIENCYEFFICIENCY

Page 13: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

CetamineBenefits for your Boiler Treatment

Does not increase the salinity within the boiler

13

Avoids chemical carry-over into the steam system

PROCESSPROCESSEFFICIENCYEFFICIENCY

Page 14: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

CetamineBenefits for your Boiler Treatment

Dosing a single liquid product rather than multiple products

14

Easier to handle, no mixing or dilution,

less equipment, storage and cost

SIMPLESIMPLEDOSINGDOSING

Page 15: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

CetamineBenefits for your Boiler Treatment

Dosing proportional to the make-up water instead

of feed water

15

Reduces the volume and cost of dosing

COSTCOSTREDUCTIONREDUCTION

Page 16: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

CetamineBenefits for your Boiler Treatment

Lower dosing and no hydrazine, sulphites, phosphates or nitrites

16

Non-toxic and less blowdown treatment before dumping to

effluent

HEALTH &HEALTH &ENVIRONMENTENVIRONMENT

Page 17: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

CetamineBenefits for your Boiler Treatment

Complying the requirement of an easy biodegradability

(OECD 301A-F)

17

Minimizes effluent disposal charges and environmental impact

HEALTH &HEALTH &ENVIRONMENTENVIRONMENT

Page 18: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

� Complete survey of your systems and working conditions

� Laboratory support for water and deposit analysis

CetamineComprehensive service

18

� Close follow-up from our engineers from the start-up of the

treatment until stable operating conditions are obtained

� Regular on-site analysis and treatment control

Page 19: Cetamine external presentation [Mode de compatibilit ] · 6 12 Cetamine V217 50% Softened 50% RO water Chemical ES Shell 15 30 10% Softened 90% Condens. Tobacco FR Shell Cetamine

CetamineConclusion

� Efficient

� Simple

� Non toxic

19

� Reduction of blowdown

� Easy control

� Cost-effective