certificate of compliance - elmarksupport.elmark.com.pl/moxa/products/komputery_wbudowane...trc...
TRANSCRIPT
TRC Certificate of Compliance
Training Research Co., Ltd.
hereby certifies that
EMC TEST
x86 Ready-to-Run Embedded Computer Model: V481, V481-CE, V481-XPE, V481-T, V481-T-CE, V481-T-XPE
Made by
Moxa Inc. Fl. 4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien City,
Taipei, Taiwan, R.O.C.
is fulfilled (As detailed within the test report) EC Directives: 89/336/EEC, 92/31/EEC, 93/68/EEC, 2004/108/EC
EMI: EN 61000-6-4/2001, EN 61000-3-2/2000, EN 61000-3-3/1995 +A1/2001
EMS: EN 61000-6-2/2005→ EN 61000-4-2:2001, EN 61000-4-3:2002 +A1/2002, EN 61000-4-4: 2004,
EN 61000-4-5:2001, EN 61000-4-6:2003, EN 61000-4-8:2001, EN 61000-4-11:2004
Test Date: June 30, 2007
Certificate Registration No.: M47CE080058 March 14, 2008
---------------------------------------- General Manager, Frank Tsai
Nemko Laboratory Authorisation Aut. No.: ELA 131
Test Report ------------------------------------------------------------------------------- 1/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Report No. M47CE080058 Directives 89/336/EEC, 92/31/EEC, 93/68/EEC, 2004/108/EC Specifications EMC/ EN 61000-6-2/2001; EN 61000-6-4/2001
Applicant Moxa Inc. Applicant Fl. 4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien City, address Taipei, Taiwan, R.O.C.
Items tested x86 Ready-to-Run Embedded Computer Model No. V481, V481-CE, V481-XPE, V481-T, V481-T-CE, V481-T-XPE EUT Condition Engineering sample; Pre-production; Final production (Sample # M470058) Results Compliance (As detailed within this report) Date 03/14/2008 (month / day / year) (Sample received) 06/28/2007 ~ 06/30/2007 (Test) Prepared by Project Engineer (Jack Tsai) Authorized by General Manager (Frank Tsai) Issue date March 14, 2008 (month / day / year) Modifications None Tested by Training Research Co., Ltd. Office at No. 255, NanYang Street, Hsichih, Taipei Hsien 221, Taiwan Open site at No. 2, Lane 530, Pa-Lian Rd., Sec. 1, Hsichih, Taipei Hsien, Taiwan
Conditions of issue :
(1) This test report shall not be reproduced except in full, without written approval of TRC. And the test
result contained within this report only relate to the sample submitted for testing.
Authorisation Aut. No.: ELA 131
Test Report ------------------------------------------------------------------------------- 2/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Contents
CHAPTER 0 EMISSION AND SUSCEPTIBILITY STANDARDS............................ 4
Emission Standards.................................................................................................... 4
Susceptibility Standards............................................................................................. 4
CHAPTER 1 INTRODUCTION .......................................................................... 5
Description of EUT ................................................................................................... 5
Connections of EUT .................................................................................................. 6
Test method ............................................................................................................... 6
Configuration of Test Setup....................................................................................... 7
Connections of equipment ......................................................................................... 7
List of Support Equipment......................................................................................... 8
CHAPTER 2 CONDUCTED EMISSION TEST .................................................. 10
Test condition and setup .......................................................................................... 10
List of test Instrument.............................................................................................. 11
Conducted Test Placement: (Front view and Side view)......................................... 12
CHAPTER 3 RADIATED EMISSION TEST ...................................................... 13
Test condition and setup .......................................................................................... 13
List of test Instrument.............................................................................................. 14
Radiated Test Placement: (Front view and Rear view) ........................................... 15
CHAPTER 4 ELECTROSTATIC DISCHARGES IMMUNITY TEST .................... 16
ESD Test information:............................................................................................. 16
EN 61000-4-2 PHOTO OF TEST SET-UP............................................................. 19
CHAPTER 5 RADIO FREQUENCY IMMUNITY TEST...................................... 20
RS Test information: ............................................................................................... 20
EN 61000-4-3 PHOTO OF TEST SET-UP............................................................. 23
CHAPTER 6 ELECTRIC FAST TRANSIENT/BURST REQUIREMENTS TEST... 24
EFT Test information: ............................................................................................. 24
Test Report ------------------------------------------------------------------------------- 3/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-4 PHOTO OF TEST SET-UP............................................................. 27
CHAPTER 7 SURGE IMMUNITY TEST........................................................... 28
Surge Test information: ........................................................................................... 28
EN 61000-4-5 PHOTO OF TEST SET-UP............................................................. 31
CHAPTER 8 CONTINUOUS WAVE VOLTAGE IMMUNITY TEST ................... 32
CS Test information: ............................................................................................... 32
EN 61000-4-6 PHOTO OF TEST SET-UP............................................................. 35
CHAPTER 9 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST ...... 36
PFMF Test information: .......................................................................................... 36
EN 61000-4-8 PHOTO OF TEST SET-UP............................................................. 37
CHAPTER 10 VOLTAGE DIP / INTERRUPTION TEST................................... 38
DIP Test information: .............................................................................................. 38
EN 61000-4-11 PHOTO OF TEST SET-UP........................................................... 40
CHAPTER 10 HARMONICS TEST.................................................................... 41
CHAPTER 11 VOLTAGE FLUCTUATION AND FLICKER TEST........................ 42
APPENDIX A ..................................................................................................... 43
Test Result of Conducted Emissions for Mains power............................................ 43
Test Result of Conducted Emission for Telecommunication .................................. 44
APPENDIX B ..................................................................................................... 45
Test Result of Radiated Emission for Horizontal .................................................... 45
Test Result of Radiated Emission for Vertical ........................................................ 45
APPENDIX C ..................................................................................................... 46
Photographs of EUT ................................................................................................ 46
Test Report ------------------------------------------------------------------------------- 4/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 0 Emission and Susceptibility Standards Emission Standards Emission Standard European Standard International Standard
( ) EN 61000-6-3/2001 IEC 61000-6-3/1996
( X ) EN 61000-6-4/2001 IEC 61000-6-4/1997
( ) EN 50081-1/1992
( ) EN 50081-1/8.93
( X ) EN 55011/1998+A1/1999+A2/2002 CISPR 11: 1997+A1/1999+A2/2002
( ) EN 55014/4.93 CISPR 14: 1993
( ) EN 55015/12.93 CISPR 15: 1992
( ) EN 55013/2001 CISPR 13: 2001
( ) EN 55022/98 +A1/2000 +A2/2003 CISPR 22: 2002
( X ) EN 61000-3-2/2000 IEC 61000-3-2: 2000
( X ) EN 61000-3-3/1995 +A1/2001 IEC 61000-3-3: 1994 +A1/2001
Susceptibility Standards Susceptibility Standard European Standard International Standard
( ) EN 61000-6-1/2001 IEC 61000-6-1/1997
( X ) EN 61000-6-2/2005 IEC 61000-6-2/2005
( ) EN 50082-1/1997
( ) EN 50082-2/1994
( ) EN 55024/1998 +A1/2001 +A2/2003 CISPR 24/1997
( ) EN 55020/2002 CISPR 20/2002
( X ) EN 61000-4-2:2001 IEC 61000-4-2:2001
( X ) EN 61000-4-3:2002 +A1/2002 IEC 61000-4-3:2002 +A1/2002
( X ) EN 61000-4-4:2004 IEC 61000-4-4:2004
( X ) EN 61000-4-5:2001 IEC 61000-4-5:2001
( X ) EN 61000-4-6:2003 IEC 61000-4-6:2003
( X ) EN 61000-4-8:2001 IEC 61000-4-8:2001
( X ) EN 61000-4-11:2004 IEC 61000-4-11:2004
Test Report ------------------------------------------------------------------------------- 5/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 1 Introduction Description of EUT
The EUT is Intel x86 embedded computer. The feature is including CPU ( Processor )
Intel ULV Celeron M 1.0GHz Zero Cache CPU North Bridge Intel 82852GM ( GMCH, Graphic Memory Control Hub ) Memory
DDR Slot x 1 ( Maximum 1GB ) South Bridge Intel 82801DB ( ICH4, I/O Control Hub 4 ) Super I/O Winbond W83627EHF with Hardware Monitor Controller. PHY Buffer Intel 82562GZ LAN Controller RealTek Giga LAN 10\100\1000 Mbps RTL8110SCL FLASH Memory
4Mb Flash memory with SST49LF004B Storage Interface
Compact Flash Slot x 1 + IDE Slot ( 44 pin ) Extension Bus
PCI Bus with PCI104 Slot x 1 USB Interface
USB 2.0 Port x 2, Type A connector. Display Interface VGA Port x 1 Keyboard / Mouse Interface PS2 Port x 2 with Y-Cabel. Audio Interface 3.5∮ Phone Jack x 2 ( Blue:Line In, Lime:Line Out ) LAN Interface RJ45 x 2 ( 10/100 Mbps + 10/100/1000 Mbps ) Serial Interface RS-232/422/485 x 8, software-selectable, DB9 RS-232 signals: TxD, RxD, DTR, DSR, RTS, CTS, DCD, GND RS-422 signals: TxD+, TxD-, RxD+, RxD-, GND 4-wire RS-485 signals: TxD+, TxD-, RxD+, RxD-, GND 2-wire RS-485 signals: Data+, Data-, GND TTL signal: TxD, RxD, DTR, DSR, RTS, CTS, DCD, GND * Note: To use the TTL mode, it is necessary to remove the serial line driver IC. built-in 15KV ESD protection for all signals Data bits = 5, 6, 7, 8 Stop bits = 1, 1.5, 2
Test Report ------------------------------------------------------------------------------- 6/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Parity = None, Even, Odd, Space, Mark Flow Control = RTS/CTS, XON/XOFF, RS-485 ADDCTM Speed = 50 bps to 921.6 Kbps, support ANY BUAD RATE Power Interface @ V481 Base Board
ATX-10 Pin Connector. RTC Battery
CR2032 ( 220 mAh ) OTHERS
RTC, buzzer, Watchdog Timer, Reset button It offers Serial Ports*8 (DB9 housing), LAN ETH Ports*2 for 10/100 connectivity.
Connections of EUT
(1) The POWER port is connected with the AC mains supply by power cable. (2) The VGA Port connected with a monitor. (3) MIC-IN Port and Audio-OUT Port connected with a Earphone and MIC. (4) The USB port 1 connected with a USB drive. (5) The USB port 2 connected with a mouse. (6) The PS/2 Port connected with a keyboard. (7) The LAN1, LAN2 ports connected to far LAN card. (8) The P1 to P8 ports are terminated with DB9 housing.
Test method
Pretest was found that the emission of operating mode is worse than standby mode. So, the final test is made at the operating mode.
During the measurement, there are two speeds: “10x10Mbps“, “100x100Mbps“ and “continuous TX / RX at Serial Ports*8”, those speeds simultaneous set up. The software provided by the manufacturer to control the EUT in the mode of continuous TX / RX.
The test placement as the photographs showed is the worst case emission placed. (If the emission is close to the ambient, the resolution BW and view resolution will be reduced and the data will be recorded by detection of maximum hold peak mode.)
The testing configuration of test setup is showing in the next page.
Test Report ------------------------------------------------------------------------------- 7/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Configuration of Test Setup Connections of equipment
EUT: *VGA Port …………. a monitor
*MIC-IN Port ………. a Earphone and MIC.
*Audio-OUT Port…. a Earphone and MIC.
*USB#1 Port ….. a mouse
*USB#2 Port ….. a USB Flash
*PS/2-key Port ……... a PS/2 keyboard
* Serial Ports*8 DB9 housing
* AC/DC Adaptor … Manufactory: ENG Model: 3A-621DA24 I/P: 100-240VAC 50-60Hz 1.5A MAX. O/P: +24VDC 2.5A MAX. Primary: 182cm length, Non-shielded, without ferrite core Secondary: 158 cm length, Non-shielded, ferrite core
PS/2 Keyboard
PS/2 Mouse
AC mains supply
Far-end
To far LAN
Earphone
EUT
Adaptor
USBFlash
Test Report ------------------------------------------------------------------------------- 8/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
List of Support Equipment
Monitor : Viewsonic
Model No. : VS10781
Serial No. : PST05420152
FCC ID : DOC Approved
Power type : 100 ~ 240V AC 15A 50/60Hz
Power cord : Shielded, 1.83m long, No ferrite core
Data cable : Shielded, 1.46m (1.80m) long, with two ferrite cores (no ferrite core)
PS/2 Mouse : HP
Model No. : M-S34
Serial No. : LZB90714106
FCC ID : DZL211029
Power type : By PC
Power cord : Non-shielded, 1.88m long, No ferrite core
PS/2 Keyboard : HP
Model No. : 5187-0343, KB0133
Serial No. : 265987-AB1 Tch 323686-AB1, B69360MGAPW0HF
FCC ID : DoC Approved
BSMI : 3892C981, R31310
Power type : By PC
Data cable : Shielded, 1.85m length, no ferrite core
Earphones : PHILIPS
Model No : SBC-HE033
Serial No. : 670904
Power type : By EUT
Data Cable : Non-shielded, 1.05 m length, No ferrite core
USB
Flash Drive : City-Netek Inc.
Model No. : CN-2108
FCC ID : DoC Approved
Power cord : Shielded, 1.0m length, no ferrite core
Test Report ------------------------------------------------------------------------------- 9/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
PC : IBM ThinkPad T43
Model No. : 2668-IVE
Serial No. : L3TGYY
FCC ID : N/A, DoC Approved
BSMI : R33B65
DGT : ETC093LPD0126, CTL093LPD0257
Power adaptor : IBM
Part No. : 92P1018
Serial No. : 11S92P1018Z1ZAPU57M9W6 REV: D
FCC ID : N/A, DoC Approved
BSMI : D33030
Power type : 100 ~ 240VAC / 50 ~ 60Hz, 1.0 ~ 0.4A, Switching
Power cord : Primary: Non-shielded, 1.0m length, Plastic hood, No ferrite core
Secondary: Shielded, 1.84m length, Plastic hood, ferrite core
Test Report ------------------------------------------------------------------------------- 10/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 2 Conducted Emission Test
Test condition and setup All the equipment is placed and setup according to EN 55011.
(1) Mains power: The EUT is assembled on a wooden table, which is 80 cm high and placed 40 cm from the
back-wall, which is a vertical conducting plane. One LISN is for EUT, the other LISN is for support equipment. They are all placed on the conductive ground. The EUT’s LISN connect a line switch box for selecting L1 or L2, then connect to a preamplifier and receiver.
(2) Telecommunication port: The EUT is place as mains disturbance test. The communication line connected to ISN and
then the measuring receiver connected to the ISN to measured the level of voltage disturbance or current probe to measured the level of current disturbance
The spectrum scans from 150KHz to 30MHz. Conducted emission levels are detected at maximum peak mode. But if the maximum peak mode failed or over average limit, it will be measured by average detection mode.
While testing the worst-emission plot printed in the peak detection mode, and there are up to 6 highest emissions to be recorded. The plot is kept as the original data and not included in the test report.
Test Report ------------------------------------------------------------------------------- 11/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
List of test Instrument
Calibration Date
Instrument Name Model Brand Serial No. Next time
Receiver SCR3102 SCHAFFNER 012 12/09/07
Spectrum Analyzer FSL3 ROHDE & SCHWARZ
100507 12/07/07
LISN 3825/2 EMCO 9411-2284 08/18/07
LISN 3825/2 EMCO 9210-2007 08/18/07
Switch Box Sb-01 TRC 98-04 04/01/08
Pre-amplifier CNIJ69051 TRC 96061 04/01/08
Coaxial cable BNC3200B-0058 JYEBAO CL-003 04/01/08
Coaxial Cable BNC31VB-0316 JYEBAO IF-01C0069-036
04/01/08
Coaxial Cable BNC3200B-0058 JYEBAO CL-05 04/01/08
Isolation Transformer FTB-1-6 MINI- CIRCUITS
15542 04/01/08
20dB attenuator CAT-20 MIN- CIRCUITS
960113 04/01/08
50 Ohm Terminator 370BNM NARDA PWR5W 07/21/07
50 Ohm Terminator 370BNM NARDA PWR5W 07/21/07
50 Ohm Terminator 370BNM NARDA PWR5W 09/03/07
50 Ohm Terminator 370BNM NARDA PWR5W 09/03/07
ISN
ISN T400 Schaffner 19104 08/07/07
Current Probe 9208-1 Solar Electronics
Co.
0411601 07/12/07
The level of confidence of 95%, the uncertainty of measurement of conducted emission is +3.10dB / -4.84dB.
Test Result: Pass (Appendix A)
Test Report ------------------------------------------------------------------------------- 12/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Conducted Test Placement: (Front view and Side view)
Test Report ------------------------------------------------------------------------------- 13/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 3 Radiated Emission Test Test condition and setup Pretest:
Prior to the final test (OATS test), the EUT is placed in an anechoic chamber, and scan from 30MHz to 1GHz. This is done to ensure the radiation is exactly emitted from the EUT.
Final test: Final radiation measurements are made on a 10–meter, open-field test site The EUT is placed on a nonconductive table, which is 0.8m height, the top surface is 1.0 x
1.5 meter. The entire placement is according to EN 55011. The spectrum is examined from 30MHz to 1GHz measured by HP spectrum. The whole range antenna is used to measure frequency from 30MHz to 1GHz.
The final test is used the spectrum analyzer. Measure more than six top marked frequencies generated form pretest by computer step by step at each frequency. The EUT is rotated 360 degrees, and antenna is raised and lowered from 1 to 4 meters to find the maximum emission levels. The antenna is used with both horizontal and vertical polarization. Appropriated preamplifier which is made by TRC is used for improving sensitivity and precautions is taken to avoid overloading .The spectrum analyzer’s 6dB bandwidth is set to 120kHz, and the EUT is measured at quasi-peak (below 1GHz) mode. If the emission is close to the frequency band of ambient, the tester will recheck the data and the corrected data will be written in the test data sheet. If the emission is just within the ambient, the data from shielded room will be taken as the final data.
Test Report ------------------------------------------------------------------------------- 14/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
List of test Instrument
Calibration Date
EMI Receiver 8546A HP 3520A00242 09/06/07
RF Filter Section 85460A HP 3448A00217 09/06/07
Small Biconical Antenna
UBAA9114 & BBVU9135
SCHWARZECK 127 12/17/07
Pre-amplifier PA1F TRC 1FAC 04/10/08
Auto Switch Box (>30MHz)
ASB-01 TRC 9904-01 04/10/08
Coaxial Cable (Double shielded, 15 meter)
A30A30-0058-50FS-15M
JYEBAO SMA-01 04/10/08
Coaxial Cable (1.1 meter)
A30A30-0058-50FS-1M JYEBAO SMA-02 04/10/08
Receiver SCR3102 SCHAFFNER 012 12/09/07
Spectrum Analyzer FSL3 ROHDE & SCHWARZ
100507 12/07/07
Switch Box Sb-01 TRC 98-04 04/01/08
Bi-log Antenna VULB 9168 SCHWARZEBECK
9168-231 07/31/07
Pre-amplifier CNIJ69051 TRC 96061 04/01/08
Coaxial cable N30N30-JBY400 JYEBAO CL-011 04/01/08
Coaxial Cable A30A30-0316 JYEBAO CL-012 04/01/08
Coaxial Cable A30A30-0316 JYEBAO CL-013 04/01/08 ISN ISN T400 SCHAFFNER 19104 08/07/07 Current Probe 9208-1 SOLAR
ELECTRONICS CO.
0411601 07/12/07
The level of confidence of 95% , the uncertainty of measurement of radiated emission is +2.85dB / -2.77dB .
Test Result: Pass (Appendix B)
Test Report ------------------------------------------------------------------------------- 15/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Radiated Test Placement: (Front view and Rear view)
Test Report ------------------------------------------------------------------------------- 16/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 4 Electrostatic Discharges Immunity Test
ESD Test information: Test setup: Shielded room Test setup for table-top equipment at laboratory tests:
0.1 m
Ground Reference Plane
Wooden table H=0.8m 470kohmResistor
Insulation
Power Supply
VPC 0.5m X 0.5m
Horizontal coupling place 1.6m X 0.8m
Typical position for indirect discharge to VCP
Typical position for indirect discharge
Typical position for indirect discharge to HCP
EUT
0.1 m
Test Report ------------------------------------------------------------------------------- 17/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test levels: (Apply Level 2 and Level 3)
1a — Contact discharge 1b — Air discharge Level Test voltage
(kV) Level Test voltage
(kV) 1 2 1 2 2 4 2 4 3 6 3 8 4 8 4 15 X Special X Special
NOTE: “X” is an open level. The level has to be specified in the dedicated equipment specification. If higher voltages than those shown are specified, special test equipment may be needed.
Test Voltage: 4KV contact discharge 8KV air discharge Indirect Discharges: HCP VCP Polarity: Positive Negative Test points: Each Connector and Enclosure of EUT. Test mode: Ref. Test method of Chapter 1
Test Report ------------------------------------------------------------------------------- 18/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test instruments: Name Model Number Serial Number Selected Best Plus BURST ESD SURGE TRANSIENTS
Best Plus V6.2 199749-019SC
SCHAFFNER EMV AG
NSG 438 INA 4380
253 X
BEST EMC Test Instrument
BEST EMC V2.3 (-8, -9)
199918-006SC
Comment: Performance Criteria ( ) A ( X ) B ( ) C General performance criteria of EMS: CRITERION A
The apparatus shall continue to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the apparatus is
used as intended.
CRITERION B
The apparatus shall continue to operate as intended after the test. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended.
CRITERION C
Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by
the operation of the controls.
Test Report ------------------------------------------------------------------------------- 19/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-2 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 20/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 5 Radio Frequency Immunity Test
RS Test information: Test setup: Fully anechoic chamber, According to EN 61000-4-3 Radiated Immunity Test Setup
Test levels: (Apply Level 1, 2 and 3)
Level Test Field Strength (V/m)
1 1 2 3 3 10 X Special
NOTE: the “X” is an open test level. This level may be given in the product specification.
Test Report ------------------------------------------------------------------------------- 21/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test Frequency: 80 ~ 1000 MHz, 10V/m 1400 ~ 2000 MHz, 3V/m 2000 ~ 2700 MHz, 1V/m Modulation: FM % 80% AM Modulation with 1KHz Step size: ≦1% step size Sweep time: 2.5 Second for each frequency Test mode: Refer to test method of Chapter 1 Test instruments: Name Model Number Serial Number Selected Amplifier Research RF Amplifier (0.8 – 3GHz)
15S1G3 305899 X
Amplifier Research 40dB Attenuator
DC7144 305930 X
Mini-Circuits RF Amplifier (20 – 500MHz)
LZT-1 N/A X
Mini-Circuits RF Amplifier (500 – 1GHz)
LZT-2 N/A X
EMCO Bi-log Antenna
3141 9711-1075 X
TRC Horn Antenna
HA0501-05 RS-01 X
HP Signal Generator
8648D 3613A00117 X
HP Power Meter
E4418B GB39291240 X
WG radiation meters
EMC-20 BN2244129 X
WG E-filed
2244 / 90.20 Z-0001 X
GW DC Power Supply
GPR-3520HD A150114 X
Test Report ------------------------------------------------------------------------------- 22/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Comment: Performance Criteria ( X ) A ( ) B ( ) C General performance criteria of EMS: CRITERION A
The apparatus shall continue to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the apparatus is
used as intended.
CRITERION B
The apparatus shall continue to operate as intended after the test. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended.
CRITERION C
Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by
the operation of the controls.
Test Report ------------------------------------------------------------------------------- 23/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-3 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 24/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 6 Electric Fast Transient/Burst Requirements Test
EFT Test information: General test set-up for laboratory type tests:
> 0.25 m
> 0.25 m
EUT
EUT
AC mains supply
EUT
EFT/B- generator
Coupling / decoupling network (A)
Non-metallic table
EUT
0.1 m
Reference plane
EFT/B- generator (B)
0.1 m
AC mains supply Capacitive
coupling clamp
Grounding connectionaccording to the manufacturer’s specification. Length to be specified in the test plan.
Insulating support
Referenceplane
(L)
(L) = length between clamp and EUT to be tested, should not be more than 1-meter
(A) = location for supply line coupling (B) = location for signal lines coupling
(L)
> 0.25 m
> 0.25 m
Test Report ------------------------------------------------------------------------------- 25/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test levels: (Apply Level 3)
Open-circuit output test voltage (±10%) and repetition rate of the impulses (±20%) On power supply port, PE On input/output signal, data and
control ports Level
Voltage peak kV
Repetition rate kHz
Voltage peak kV
Repetition rate kHz
1 0.5 5 0.25 5 2 1 5 0.5 5 3 2 5 1 5 4 4 2.5 2 5 X Special Special Special Special
NOTE: the “X” is an open level. The level has to be specified in the dedicated equipment specification
Test setup: According to EN 61000-4-4 Test Voltage: DC Power line 0.5 KV, 5 KH AC Power line 2.0 KV, 5 KHz
Signal & Control line 0.5 KV, 5 KHz 1.0 KV, 5 KHz Polarity: Positive Negative Test Duration: 1 minute 3 minutes Connected lines: Power line shielded Power line non-shielded Signal & Control line non-shielded Signal & Control line shielded
Test Report ------------------------------------------------------------------------------- 26/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test mode: Ref. Test method of Chapter 1. Test instrument: Name Model Number Serial Number Selected Best Plus BURST ESD SURGE TRANSIENTS
Best Plus V6.2 199749-019SC
KeyTek Instrument EFT Test system
E412 9505206/505207 X
BEST EMC Test Instrument
BEST EMC V2.3 (-8, -9)
199918-006SC
Comment: Performance Criteria ( ) A ( X ) B ( ) C General performance criteria of EMS: CRITERION A
The apparatus shall continue to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the apparatus is
used as intended.
CRITERION B
The apparatus shall continue to operate as intended after the test. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended.
CRITERION C
Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by
the operation of the controls.
Test Report ------------------------------------------------------------------------------- 27/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-4 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 28/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 7 Surge Immunity Test
Surge Test information: Test setup: According to EN 61000-4-5 Test levels: (Apply Level 2 and Level 3)
Level Test Field Strength (kV)
1 0.5 2 1.0 3 2.0 4 4.0 X Special
NOTE: the “X” is an open class. This level may be specified in the product specification.
Coupling Line Voltage(kV) Polarity Coupling Method Load (ohm) L-N 1 Positive./Negative Capacitive 2
L-N to Ground 2 Positive./Negative Capacitive 12 LAN 1 Positive./Negative Capacitive 42
Ground Reference Plane
Surge Immunity Test (KeyTek Pulsed-EMI Test System)
0.8m
EUT
PC System Monitor
Ethernet LAN System
Simulator
Test Report ------------------------------------------------------------------------------- 29/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test Voltage: DC Power line 0.5 KV AC Power line Line – Line: 1KV Line – Ground: 2KV
Control line 0.5 KV
Signal 1 KV Voltage waveform: 1.2/50µs Current waveform: 8/20µs Polarity: Positive Negative Connected lines: Power line shielded Power line non-shielded Signal & Control line non-shielded Signal & Control line shielded Test mode: Ref. Test method of Chapter 1. Test instrument: Name Model Number Serial Number Selected Best Plus BURST ESD SURGE TRANSIENTS
Best Plus V6.2 199749-019SC
BEST EMC Test Instrument
BEST EMC V2.3 (-8, -9)
199918-006SC
KeyTek Pulsed-EMI Test System
E501B 0008260 X
KeyTek Pulsed-EMI Test System
E4552A 0008264 X
Test Report ------------------------------------------------------------------------------- 30/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Comment: Performance Criteria ( ) A ( X ) B ( ) C General performance criteria of EMS: CRITERION A
The apparatus shall continue to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the apparatus is
used as intended.
CRITERION B
The apparatus shall continue to operate as intended after the test. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended.
CRITERION C
Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by
the operation of the controls.
Test Report ------------------------------------------------------------------------------- 31/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-5 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 32/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 8 Continuous Wave Voltage Immunity Test
CS Test information: Test setup: According to EN 61000-4-6 Immunity test to RF conducted disturbances: Test levels: (Apply Level 3)
Frequency range 150kHz to 80MHz Voltage level (e.m.f.)
Level Uo [dB(µv)] Uo [V]
1 120 1 2 130 3 3 140 10 X Special
NOTE: the “X” is an open test level.
CDN Auxiliary
equipment 1 Equipment under test CDN
Auxiliary equipment 1
T
Ground reference plane 0.1 m support
RF — generator
T2
T: Termination 50ohm T2: Power attenuator
(6dB)
CDN: Coupling and decoupling network
Test Report ------------------------------------------------------------------------------- 33/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test Frequency: 0.15 ~ 80MHz Modulation: FM % 80% AM Modulation with 1KHz Step size: ≦1% Step size Signal Strength: 1Vrms 3Vrms 10Vrms Test mode: Ref. Test method of Chapter 1 Test instruments: Name Model Number Serial Number Selected FRANKONIA EMV–Mess–System
CIT-10 103A3113 X
FRANKONIA CDN
M2+M3 A3011015 X
FRANKONIA CDN
T2-801 A3010002
FRANKONIA CDN
T4-801 A3015004 X
FRANKONIA CDN
S1-801 A3005002
SCHAFFNER FM-Koppelzange
KEMZ 801 17045
Test Report ------------------------------------------------------------------------------- 34/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Comment: Performance Criteria ( X ) A ( ) B ( ) C General performance criteria of EMS: CRITERION A
The apparatus shall continue to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the apparatus is
used as intended.
CRITERION B
The apparatus shall continue to operate as intended after the test. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended.
CRITERION C
Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by
the operation of the controls.
Test Report ------------------------------------------------------------------------------- 35/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-6 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 36/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 9 Power Frequency Magnetic Field Immunity Test
PFMF Test information: Test setup: According to EN 61000-4-8 Testing site: Temperature : 23° C Humidity : 64 % RH Test setup: According to EN 61000-4-8 Test method : ( X ) Continuous ( ) Short duration Magnetic Field Strength: ( ) 1A/m ( ) 10A/m ( X ) 100A/m Frequency: 50Hz polarization: ( X ) X polarization ( X ) Y polarization ( X ) Z polarization Test mode: Ref. Test method of Chapter 1 Test Duration: ( X ) 30 seconds ( ) 1~3 seconds Connected lines: ( ) Power line shielded ( X ) Power line non-shielded ( X ) Signal & Control line non-shielded ( ) Signal & Control line shielded ** Power Frequency Magnetic Field in the horizontal and vertical polarity.** Test instruments: Name Model Number Serial Number Selected Partner EMS Tester
Transienter-1000 PIO X
EMC Partner EUT-Power Transient-1000
MF1000-1-75 X
Comment: Performance Criteria: ( X ) A ( ) B ( ) C Test Result : Pass
Test Report ------------------------------------------------------------------------------- 37/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-8 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 38/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 10 Voltage DIP / Interruption Test DIP Test information: Test setup: According to EN 61000-4-11 Voltage dips: 100% , 1 Period 30% , 25 Period 60% , 10 Period Voltage interruptions: 100% , 250 Periods Test mode: Ref. Test method of Chapter 1 Test instruments: Name Model Number Serial Number Selected Best Plus BURST ESDSURGE TRANSIENTS
Best Plus V6.2 199749-019SC
BEST EMC Test Instrument
BEST EMC V2.3 (-8, -9)
199918-006SC
Partner EMS Tester
Transienter-1000 PIO X
Test Report ------------------------------------------------------------------------------- 39/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Comment: Performance Criteria: Dips (1) 100% ( ) A ( X ) B ( ) C Dips (2) 30% ( ) A ( ) B ( X ) C Dips (3) 60% ( ) A ( ) B ( X ) C Interruptions (1) 100% ( ) A ( ) B ( X ) C General performance criteria of EMS: CRITERION A
The apparatus shall continue to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the apparatus is
used as intended.
CRITERION B
The apparatus shall continue to operate as intended after the test. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended.
CRITERION C
Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by
the operation of the controls.
Test Report ------------------------------------------------------------------------------- 40/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-11 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 41/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 10 Harmonics Test Test information: Test setup: According to EN 61000-3-2 Test Item: Quasi – stationary & Fluctuating Current Harmonics Test. Test mode: Ref. Test method of Chapter 1 Test instrument: Name Model Number Serial Number Harmonic/ Flicker Test System
HP 6843A 3531A-00227
Test Equipment Settings: Quasi-stationary Current
Harmonics Test Fluctuating Current Harmonics Test
Line Voltage 230VAC
230VAC
Line Frequency 50Hz
50Hz
Device Class A
A
Test Limit Overrides None
None
Total Number of Failures None
None
Total Number of Errors None
None
Test Result: Pass
Test Report ------------------------------------------------------------------------------- 42/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 11 Voltage Fluctuation and Flicker Test
Test information: Test setup: According to EN 61000-3-3 Test mode: Ref. Test method of Chapter 1 Test instrument: Name Model Number Serial Number Harmonic/Flicker Test System
HP 6843A 3531A-00227
Test Equipment Settings Line Voltage
230VAC
Line Frequency
50Hz
Test Limit Overrides
None
Total Number of Failures
Pst: (0), Plt: (0) Dc: (0), Dmax (0), Dt (0)
Total Number of Errors
None
Test Result: Pass
Test Report ------------------------------------------------------------------------------- 43/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Appendix A Test Result of Conducted Emissions for Mains power
Testing room : Temperature : 25 ° C Humidity : 73 % RH Line 1
READING AMPLITUDE LIMIT Frequency
(kHz) Peak
(dBµV) Quasi-Peak
(dBµV) Average (dBµV)
Quasi-Peak(dBµV)
Average (dBµV)
Margin
(dB)
191.000 50.19 --- --- 79.00 66.00 -15.81317.000 46.74 --- --- 79.00 66.00 -19.26572.000 45.08 --- --- 73.00 60.00 -14.92
1334.000 45.38 --- --- 73.00 60.00 -14.622208.000 47.50 --- --- 73.00 60.00 -12.503040.000 47.58 --- --- 73.00 60.00 -12.424688.000 47.53 --- --- 73.00 60.00 -12.477360.000 42.51 --- --- 73.00 60.00 -17.49
24120.000 33.12 --- --- 73.00 60.00 -26.88
Line 2 READING AMPLITUDE LIMIT
Frequency (kHz)
Peak (dBµV)
Quasi-Peak(dBµV)
Average (dBµV)
Quasi-Peak(dBµV)
Average (dBµV)
Margin
(dB)
150.000 52.20 --- --- 79.00 66.00 -13.80191.000 50.25 --- --- 79.00 66.00 -15.75317.000 48.69 --- --- 79.00 66.00 -17.31
1012.000 44.92 --- --- 73.00 60.00 -15.081837.000 46.93 --- --- 73.00 60.00 -13.073040.000 47.42 --- --- 73.00 60.00 -12.584688.000 46.70 --- --- 73.00 60.00 -13.307360.000 43.47 --- --- 73.00 60.00 -16.53
29420.000 33.48 --- --- 73.00 60.00 -26.52
Note: 1. The reading amplitudes are all under limit. 2. Testing result = Amplitude reading + Correction factor (Insertion loss of LISN, Cable loss,
Attenuator, Amplifier and so on)
Test Report ------------------------------------------------------------------------------- 44/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test Result of Conducted Emission for Telecommunication
Testing room : Temperature : 25.0 ° C Humidity : 73.0 % RH 10Mbps
READING AMPLITUDE LIMIT Frequency
(KHz) Peak
(dBµV) Quasi-Peak
(dBµV) Average (dBµV)
Quasi-Peak(dBµV)
Average (dBµV)
Margin
(dB)
187.000 41.75 --- --- 95.94 82.94 -41.19250.000 36.30 --- --- 94.14 81.14 -44.84504.000 42.85 --- --- 87.00 74.00 -31.15
1437.000 50.59 --- --- 87.00 74.00 -23.411924.000 48.01 --- --- 87.00 74.00 -25.993004.000 42.38 --- --- 87.00 74.00 -31.628610.000 48.10 --- --- 87.00 74.00 -25.90
12250.000 42.48 --- --- 87.00 74.00 -31.5215270.000 36.35 --- --- 87.00 74.00 -37.65
100Mbps
READING AMPLITUDE LIMIT Frequency
(KHz) Peak
(dBµV) Quasi-Peak
(dBµV) Average (dBµV)
Quasi-Peak(dBµV)
Average (dBµV)
Margin
(dB)
191.000 41.82 --- --- 95.83 82.83 -41.01366.000 46.10 --- --- 90.83 77.83 -31.73622.000 46.83 --- --- 87.00 74.00 -27.17
1017.000 53.60 --- --- 87.00 74.00 -20.401503.000 51.86 --- --- 87.00 74.00 -22.143030.000 54.70 --- --- 87.00 74.00 -19.305240.000 56.65 --- --- 87.00 74.00 -17.357930.000 54.84 --- --- 87.00 74.00 -19.16
16160.000 62.92 --- --- 87.00 74.00 -11.0823120.000 63.05 --- --- 87.00 74.00 -10.95
Test Report ------------------------------------------------------------------------------- 45/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Appendix B Test Conditions: Testing room : Temperature : 25 ° C Humidity : 73 % RH Testing site : Temperature : 25 ° C Humidity : 73 % RH Test Result of Radiated Emission for Horizontal
Frequency Reading Amplitude
Ant. Height
Table
Correction Factors
Corrected Amplitude
Class A Limit
Margin
MHz dBµV m degree dB/m dBµV/m dBµV/m dB
250.0070 38.20 3.57 0 -4.95 33.25 47.00 -13.75
331.7640 37.87 1.00 46 -1.81 36.06 47.00 -10.94
500.0150 30.75 2.27 0 2.91 33.66 47.00 -13.34
600.4280 33.76 2.41 327 5.86 39.62 47.00 -7.38 Test Result of Radiated Emission for Vertical
Frequency Reading Amplitude
Ant. Height
Table
Correction Factors
Corrected Amplitude
Class A Limit
Margin
MHz dBµV m degree dB/m dBµV/m dBµV/m dB
120.0010 37.57 1.00 137 -7.26 30.31 40.00 -9.69
145.9220 35.77 1.00 124 -4.72 31.05 40.00 -8.95
196.1960 36.90 3.63 0 -6.57 30.33 40.00 -9.67
596.9610 33.68 2.80 74 5.75 39.43 47.00 -7.57
940.8420 28.84 3.94 0 11.17 40.01 47.00 -6.99
Note: 1. Margin = Amplitude – limit, if margin is minus means under limit. 2. Corrected Amplitude = Reading Amplitude + Correction Factors 3. Correction factor = Antenna factor + (Cable Loss – Amplitude gain) + Switching Box Loss
Test Report ------------------------------------------------------------------------------- 46/55
Report No.: M47CE080058 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Appendix C
Photographs of EUT
External Photos of EUT ------------------------------------------------------------ 47/55
External Photos of EUT ------------------------------------------------------------ 48/55
Power Supply of EUT --------------------------------------------------------------- 49/55
Internal Photos of EUT ------------------------------------------------------------- 50/55
Internal Photos of EUT ------------------------------------------------------------- 51/55
Internal Photos of EUT ------------------------------------------------------------- 52/55
Internal Photos of EUT ------------------------------------------------------------- 53/55
Internal Photos of EUT ------------------------------------------------------------- 54/55
Internal Photos of EUT ------------------------------------------------------------- 55/55
TRC Certificate of Compliance
Training Research Co., Ltd.
hereby certifies that
EMC TEST
x86 Ready-to-Run Embedded Computer Model: ThinkCore V481, ThinkCore V481-CE, ThinkCore V481-XPE, ThinkCore V481-T, ThinkCore V481-T-CE, ThinkCore V481-T-XPE
Made by
Moxa Technologies Co., Ltd. Fl. 4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien City,
Taipei, Taiwan, R.O.C.
is fulfilled (As detailed within the test report) EC Directives: 89/336/EEC, 92/31/EEC, 93/68/EEC, 2004/108/EC
EMI: EN 61000-6-4/2001, EN 61000-3-2/2000, EN 61000-3-3/1995 +A1/2001
EMS: EN 61000-6-2/2005→ EN 61000-4-2:2001, EN 61000-4-3:2002 +A1/2002, EN 61000-4-4: 2004,
EN 61000-4-5:2001, EN 61000-4-6:2003, EN 61000-4-8:2001, EN 61000-4-11:2004
Test Date: June 30, 2007
Certificate Registration No.: M47CE061207 June 30, 2007
---------------------------------------- General Manager, Frank Tsai
Nemko Laboratory Authorisation Aut. No.: ELA 131
Test Report ------------------------------------------------------------------------------- 1/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Report No. M47CE061207 Directives 89/336/EEC, 92/31/EEC, 93/68/EEC, 2004/108/EC Specifications EMC/ EN 61000-6-2/2001; EN 61000-6-4/2001
Applicant Moxa Technologies Co., Ltd. Applicant Fl. 4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien City, address Taipei, Taiwan, R.O.C.
Items tested x86 Ready-to-Run Embedded Computer Model No. ThinkCore V481, ThinkCore V481-CE, ThinkCore
V481-XPE, ThinkCore V481-T, ThinkCore V481-T-CE, ThinkCore V481-T-XPE
EUT Condition Engineering sample; Pre-production; Final production (Sample # M471207) Results Compliance (As detailed within this report) Date 06/28/2007 (month / day / year) (Sample received) 06/28/2007 ~ 06/30/2007 (Test) Prepared by Project Engineer (Jack Tsai) Authorized by General Manager (Frank Tsai) Issue date June 30, 2007 (month / day / year) Modifications None Tested by Training Research Co., Ltd. Office at No. 255, NanYang Street, Hsichih, Taipei Hsien 221, Taiwan Open site at No. 2, Lane 530, Pa-Lian Rd., Sec. 1, Hsichih, Taipei Hsien, Taiwan
Conditions of issue :
(1) This test report shall not be reproduced except in full, without written approval of TRC. And the test
result contained within this report only relate to the sample submitted for testing.
Authorisation Aut. No.: ELA 131
Test Report ------------------------------------------------------------------------------- 2/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Contents
CHAPTER 0 EMISSION AND SUSCEPTIBILITY STANDARDS............................ 4
Emission Standards.................................................................................................... 4
Susceptibility Standards............................................................................................. 4
CHAPTER 1 INTRODUCTION .......................................................................... 5
Description of EUT ................................................................................................... 5
Connections of EUT .................................................................................................. 6
Test method ............................................................................................................... 6
Configuration of Test Setup....................................................................................... 7
Connections of equipment ......................................................................................... 7
List of Support Equipment......................................................................................... 8
CHAPTER 2 CONDUCTED EMISSION TEST .................................................. 10
Test condition and setup .......................................................................................... 10
List of test Instrument.............................................................................................. 11
Conducted Test Placement: (Front view and Side view)......................................... 12
CHAPTER 3 RADIATED EMISSION TEST ...................................................... 13
Test condition and setup .......................................................................................... 13
List of test Instrument.............................................................................................. 14
Radiated Test Placement: (Front view and Rear view) ........................................... 15
CHAPTER 4 ELECTROSTATIC DISCHARGES IMMUNITY TEST .................... 16
ESD Test information:............................................................................................. 16
EN 61000-4-2 PHOTO OF TEST SET-UP............................................................. 19
CHAPTER 5 RADIO FREQUENCY IMMUNITY TEST...................................... 20
RS Test information: ............................................................................................... 20
EN 61000-4-3 PHOTO OF TEST SET-UP............................................................. 23
CHAPTER 6 ELECTRIC FAST TRANSIENT/BURST REQUIREMENTS TEST... 24
EFT Test information: ............................................................................................. 24
Test Report ------------------------------------------------------------------------------- 3/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-4 PHOTO OF TEST SET-UP............................................................. 27
CHAPTER 7 SURGE IMMUNITY TEST........................................................... 28
Surge Test information: ........................................................................................... 28
EN 61000-4-5 PHOTO OF TEST SET-UP............................................................. 31
CHAPTER 8 CONTINUOUS WAVE VOLTAGE IMMUNITY TEST ................... 32
CS Test information: ............................................................................................... 32
EN 61000-4-6 PHOTO OF TEST SET-UP............................................................. 35
CHAPTER 9 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST ...... 36
PFMF Test information: .......................................................................................... 36
EN 61000-4-8 PHOTO OF TEST SET-UP............................................................. 37
CHAPTER 10 VOLTAGE DIP / INTERRUPTION TEST................................... 38
DIP Test information: .............................................................................................. 38
EN 61000-4-11 PHOTO OF TEST SET-UP........................................................... 40
CHAPTER 10 HARMONICS TEST.................................................................... 41
CHAPTER 11 VOLTAGE FLUCTUATION AND FLICKER TEST........................ 42
APPENDIX A ..................................................................................................... 43
Test Result of Conducted Emissions for Mains power............................................ 43
Test Result of Conducted Emission for Telecommunication .................................. 44
APPENDIX B ..................................................................................................... 45
Test Result of Radiated Emission for Horizontal .................................................... 45
Test Result of Radiated Emission for Vertical ........................................................ 45
APPENDIX C ..................................................................................................... 46
Photographs of EUT ................................................................................................ 46
Test Report ------------------------------------------------------------------------------- 4/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 0 Emission and Susceptibility Standards Emission Standards Emission Standard European Standard International Standard
( ) EN 61000-6-3/2001 IEC 61000-6-3/1996
( X ) EN 61000-6-4/2001 IEC 61000-6-4/1997
( ) EN 50081-1/1992
( ) EN 50081-1/8.93
( X ) EN 55011/1998+A1/1999+A2/2002 CISPR 11: 1997+A1/1999+A2/2002
( ) EN 55014/4.93 CISPR 14: 1993
( ) EN 55015/12.93 CISPR 15: 1992
( ) EN 55013/2001 CISPR 13: 2001
( ) EN 55022/98 +A1/2000 +A2/2003 CISPR 22: 2002
( X ) EN 61000-3-2/2000 IEC 61000-3-2: 2000
( X ) EN 61000-3-3/1995 +A1/2001 IEC 61000-3-3: 1994 +A1/2001
Susceptibility Standards Susceptibility Standard European Standard International Standard
( ) EN 61000-6-1/2001 IEC 61000-6-1/1997
( X ) EN 61000-6-2/2005 IEC 61000-6-2/2005
( ) EN 50082-1/1997
( ) EN 50082-2/1994
( ) EN 55024/1998 +A1/2001 +A2/2003 CISPR 24/1997
( ) EN 55020/2002 CISPR 20/2002
( X ) EN 61000-4-2:2001 IEC 61000-4-2:2001
( X ) EN 61000-4-3:2002 +A1/2002 IEC 61000-4-3:2002 +A1/2002
( X ) EN 61000-4-4:2004 IEC 61000-4-4:2004
( X ) EN 61000-4-5:2001 IEC 61000-4-5:2001
( X ) EN 61000-4-6:2003 IEC 61000-4-6:2003
( X ) EN 61000-4-8:2001 IEC 61000-4-8:2001
( X ) EN 61000-4-11:2004 IEC 61000-4-11:2004
Test Report ------------------------------------------------------------------------------- 5/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 1 Introduction Description of EUT
The EUT is Intel x86 embedded computer. The feature is including CPU ( Processor )
Intel ULV Celeron M 1.0GHz Zero Cache CPU North Bridge Intel 82852GM ( GMCH, Graphic Memory Control Hub ) Memory
DDR Slot x 1 ( Maximum 1GB ) South Bridge Intel 82801DB ( ICH4, I/O Control Hub 4 ) Super I/O Winbond W83627EHF with Hardware Monitor Controller. PHY Buffer Intel 82562GZ LAN Controller RealTek Giga LAN 10\100\1000 Mbps RTL8110SCL FLASH Memory
4Mb Flash memory with SST49LF004B Storage Interface
Compact Flash Slot x 1 + IDE Slot ( 44 pin ) Extension Bus
PCI Bus with PCI104 Slot x 1 USB Interface
USB 2.0 Port x 2, Type A connector. Display Interface VGA Port x 1 Keyboard / Mouse Interface PS2 Port x 2 with Y-Cabel. Audio Interface 3.5∮ Phone Jack x 2 ( Blue:Line In, Lime:Line Out ) LAN Interface RJ45 x 2 ( 10/100 Mbps + 10/100/1000 Mbps ) Serial Interface RS-232/422/485 x 8, software-selectable, DB9 RS-232 signals: TxD, RxD, DTR, DSR, RTS, CTS, DCD, GND RS-422 signals: TxD+, TxD-, RxD+, RxD-, GND 4-wire RS-485 signals: TxD+, TxD-, RxD+, RxD-, GND 2-wire RS-485 signals: Data+, Data-, GND TTL signal: TxD, RxD, DTR, DSR, RTS, CTS, DCD, GND * Note: To use the TTL mode, it is necessary to remove the serial line driver IC. built-in 15KV ESD protection for all signals Data bits = 5, 6, 7, 8 Stop bits = 1, 1.5, 2
Test Report ------------------------------------------------------------------------------- 6/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Parity = None, Even, Odd, Space, Mark Flow Control = RTS/CTS, XON/XOFF, RS-485 ADDCTM Speed = 50 bps to 921.6 Kbps, support ANY BUAD RATE Power Interface @ V481 Base Board
ATX-10 Pin Connector. RTC Battery
CR2032 ( 220 mAh ) OTHERS
RTC, buzzer, Watchdog Timer, Reset button It offers Serial Ports*8 (DB9 housing), LAN ETH Ports*2 for 10/100 connectivity.
Connections of EUT
(1) The POWER port is connected with the AC mains supply by power cable. (2) The VGA Port connected with a monitor. (3) MIC-IN Port and Audio-OUT Port connected with a Earphone and MIC. (4) The USB port 1 connected with a USB drive. (5) The USB port 2 connected with a mouse. (6) The PS/2 Port connected with a keyboard. (7) The LAN1, LAN2 ports connected to far LAN card. (8) The P1 to P8 ports are terminated with DB9 housing.
Test method
Pretest was found that the emission of operating mode is worse than standby mode. So, the final test is made at the operating mode.
During the measurement, there are two speeds: “10x10Mbps“, “100x100Mbps“ and “continuous TX / RX at Serial Ports*8”, those speeds simultaneous set up. The software provided by the manufacturer to control the EUT in the mode of continuous TX / RX.
The test placement as the photographs showed is the worst case emission placed. (If the emission is close to the ambient, the resolution BW and view resolution will be reduced and the data will be recorded by detection of maximum hold peak mode.)
The testing configuration of test setup is showing in the next page.
Test Report ------------------------------------------------------------------------------- 7/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Configuration of Test Setup Connections of equipment
EUT: *VGA Port …………. a monitor
*MIC-IN Port ………. a Earphone and MIC.
*Audio-OUT Port…. a Earphone and MIC.
*USB#1 Port ….. a mouse
*USB#2 Port ….. a USB Flash
*PS/2-key Port ……... a PS/2 keyboard
* Serial Ports*8 DB9 housing
* AC/DC Adaptor … Manufactory: ENG Model: 3A-621DA24 I/P: 100-240VAC 50-60Hz 1.5A MAX. O/P: +24VDC 2.5A MAX. Primary: 182cm length, Non-shielded, without ferrite core Secondary: 158 cm length, Non-shielded, ferrite core
PS/2 Keyboard
PS/2 Mouse
AC mains supply
Far-end
To far LAN
Earphone
EUT
Adaptor
USBFlash
Test Report ------------------------------------------------------------------------------- 8/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
List of Support Equipment
Monitor : Viewsonic
Model No. : VS10781
Serial No. : PST05420152
FCC ID : DOC Approved
Power type : 100 ~ 240V AC 15A 50/60Hz
Power cord : Shielded, 1.83m long, No ferrite core
Data cable : Shielded, 1.46m (1.80m) long, with two ferrite cores (no ferrite core)
PS/2 Mouse : HP
Model No. : M-S34
Serial No. : LZB90714106
FCC ID : DZL211029
Power type : By PC
Power cord : Non-shielded, 1.88m long, No ferrite core
PS/2 Keyboard : HP
Model No. : 5187-0343, KB0133
Serial No. : 265987-AB1 Tch 323686-AB1, B69360MGAPW0HF
FCC ID : DoC Approved
BSMI : 3892C981, R31310
Power type : By PC
Data cable : Shielded, 1.85m length, no ferrite core
Earphones : PHILIPS
Model No : SBC-HE033
Serial No. : 670904
Power type : By EUT
Data Cable : Non-shielded, 1.05 m length, No ferrite core
USB
Flash Drive : City-Netek Inc.
Model No. : CN-2108
FCC ID : DoC Approved
Power cord : Shielded, 1.0m length, no ferrite core
Test Report ------------------------------------------------------------------------------- 9/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
PC : IBM ThinkPad T43
Model No. : 2668-IVE
Serial No. : L3TGYY
FCC ID : N/A, DoC Approved
BSMI : R33B65
DGT : ETC093LPD0126, CTL093LPD0257
Power adaptor : IBM
Part No. : 92P1018
Serial No. : 11S92P1018Z1ZAPU57M9W6 REV: D
FCC ID : N/A, DoC Approved
BSMI : D33030
Power type : 100 ~ 240VAC / 50 ~ 60Hz, 1.0 ~ 0.4A, Switching
Power cord : Primary: Non-shielded, 1.0m length, Plastic hood, No ferrite core
Secondary: Shielded, 1.84m length, Plastic hood, ferrite core
Test Report ------------------------------------------------------------------------------- 10/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 2 Conducted Emission Test
Test condition and setup All the equipment is placed and setup according to EN 55011.
(1) Mains power: The EUT is assembled on a wooden table, which is 80 cm high and placed 40 cm from the
back-wall, which is a vertical conducting plane. One LISN is for EUT, the other LISN is for support equipment. They are all placed on the conductive ground. The EUT’s LISN connect a line switch box for selecting L1 or L2, then connect to a preamplifier and receiver.
(2) Telecommunication port: The EUT is place as mains disturbance test. The communication line connected to ISN and
then the measuring receiver connected to the ISN to measured the level of voltage disturbance or current probe to measured the level of current disturbance
The spectrum scans from 150KHz to 30MHz. Conducted emission levels are detected at maximum peak mode. But if the maximum peak mode failed or over average limit, it will be measured by average detection mode.
While testing the worst-emission plot printed in the peak detection mode, and there are up to 6 highest emissions to be recorded. The plot is kept as the original data and not included in the test report.
Test Report ------------------------------------------------------------------------------- 11/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
List of test Instrument
Calibration Date
Instrument Name Model Brand Serial No. Next time
Receiver SCR3102 SCHAFFNER 012 12/09/07
Spectrum Analyzer FSL3 ROHDE & SCHWARZ
100507 12/07/07
LISN 3825/2 EMCO 9411-2284 08/18/07
LISN 3825/2 EMCO 9210-2007 08/18/07
Switch Box Sb-01 TRC 98-04 04/01/08
Pre-amplifier CNIJ69051 TRC 96061 04/01/08
Coaxial cable BNC3200B-0058 JYEBAO CL-003 04/01/08
Coaxial Cable BNC31VB-0316 JYEBAO IF-01C0069-036
04/01/08
Coaxial Cable BNC3200B-0058 JYEBAO CL-05 04/01/08
Isolation Transformer FTB-1-6 MINI- CIRCUITS
15542 04/01/08
20dB attenuator CAT-20 MIN- CIRCUITS
960113 04/01/08
50 Ohm Terminator 370BNM NARDA PWR5W 07/21/07
50 Ohm Terminator 370BNM NARDA PWR5W 07/21/07
50 Ohm Terminator 370BNM NARDA PWR5W 09/03/07
50 Ohm Terminator 370BNM NARDA PWR5W 09/03/07
ISN
ISN T400 Schaffner 19104 08/07/07
Current Probe 9208-1 Solar Electronics
Co.
0411601 07/12/07
The level of confidence of 95%, the uncertainty of measurement of conducted emission is +3.10dB / -4.84dB.
Test Result: Pass (Appendix A)
Test Report ------------------------------------------------------------------------------- 12/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Conducted Test Placement: (Front view and Side view)
Test Report ------------------------------------------------------------------------------- 13/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 3 Radiated Emission Test Test condition and setup Pretest:
Prior to the final test (OATS test), the EUT is placed in an anechoic chamber, and scan from 30MHz to 1GHz. This is done to ensure the radiation is exactly emitted from the EUT.
Final test: Final radiation measurements are made on a 10–meter, open-field test site The EUT is placed on a nonconductive table, which is 0.8m height, the top surface is 1.0 x
1.5 meter. The entire placement is according to EN 55011. The spectrum is examined from 30MHz to 1GHz measured by HP spectrum. The whole range antenna is used to measure frequency from 30MHz to 1GHz.
The final test is used the spectrum analyzer. Measure more than six top marked frequencies generated form pretest by computer step by step at each frequency. The EUT is rotated 360 degrees, and antenna is raised and lowered from 1 to 4 meters to find the maximum emission levels. The antenna is used with both horizontal and vertical polarization. Appropriated preamplifier which is made by TRC is used for improving sensitivity and precautions is taken to avoid overloading .The spectrum analyzer’s 6dB bandwidth is set to 120kHz, and the EUT is measured at quasi-peak (below 1GHz) mode. If the emission is close to the frequency band of ambient, the tester will recheck the data and the corrected data will be written in the test data sheet. If the emission is just within the ambient, the data from shielded room will be taken as the final data.
Test Report ------------------------------------------------------------------------------- 14/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
List of test Instrument
Calibration Date
EMI Receiver 8546A HP 3520A00242 09/06/07
RF Filter Section 85460A HP 3448A00217 09/06/07
Small Biconical Antenna
UBAA9114 & BBVU9135
SCHWARZECK 127 12/17/07
Pre-amplifier PA1F TRC 1FAC 04/10/08
Auto Switch Box (>30MHz)
ASB-01 TRC 9904-01 04/10/08
Coaxial Cable (Double shielded, 15 meter)
A30A30-0058-50FS-15M
JYEBAO SMA-01 04/10/08
Coaxial Cable (1.1 meter)
A30A30-0058-50FS-1M JYEBAO SMA-02 04/10/08
Receiver SCR3102 SCHAFFNER 012 12/09/07
Spectrum Analyzer FSL3 ROHDE & SCHWARZ
100507 12/07/07
Switch Box Sb-01 TRC 98-04 04/01/08
Bi-log Antenna VULB 9168 SCHWARZEBECK
9168-231 07/31/07
Pre-amplifier CNIJ69051 TRC 96061 04/01/08
Coaxial cable N30N30-JBY400 JYEBAO CL-011 04/01/08
Coaxial Cable A30A30-0316 JYEBAO CL-012 04/01/08
Coaxial Cable A30A30-0316 JYEBAO CL-013 04/01/08 ISN ISN T400 SCHAFFNER 19104 08/07/07 Current Probe 9208-1 SOLAR
ELECTRONICS CO.
0411601 07/12/07
The level of confidence of 95% , the uncertainty of measurement of radiated emission is +2.85dB / -2.77dB .
Test Result: Pass (Appendix B)
Test Report ------------------------------------------------------------------------------- 15/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Radiated Test Placement: (Front view and Rear view)
Test Report ------------------------------------------------------------------------------- 16/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 4 Electrostatic Discharges Immunity Test
ESD Test information: Test setup: Shielded room Test setup for table-top equipment at laboratory tests:
0.1 m
Ground Reference Plane
Wooden table H=0.8m 470kohmResistor
Insulation
Power Supply
VPC 0.5m X 0.5m
Horizontal coupling place 1.6m X 0.8m
Typical position for indirect discharge to VCP
Typical position for indirect discharge
Typical position for indirect discharge to HCP
EUT
0.1 m
Test Report ------------------------------------------------------------------------------- 17/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test levels: (Apply Level 2 and Level 3)
1a — Contact discharge 1b — Air discharge Level Test voltage
(kV) Level Test voltage
(kV) 1 2 1 2 2 4 2 4 3 6 3 8 4 8 4 15 X Special X Special
NOTE: “X” is an open level. The level has to be specified in the dedicated equipment specification. If higher voltages than those shown are specified, special test equipment may be needed.
Test Voltage: 4KV contact discharge 8KV air discharge Indirect Discharges: HCP VCP Polarity: Positive Negative Test points: Each Connector and Enclosure of EUT. Test mode: Ref. Test method of Chapter 1
Test Report ------------------------------------------------------------------------------- 18/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test instruments: Name Model Number Serial Number Selected Best Plus BURST ESD SURGE TRANSIENTS
Best Plus V6.2 199749-019SC
SCHAFFNER EMV AG
NSG 438 INA 4380
253 X
BEST EMC Test Instrument
BEST EMC V2.3 (-8, -9)
199918-006SC
Comment: Performance Criteria ( ) A ( X ) B ( ) C General performance criteria of EMS: CRITERION A
The apparatus shall continue to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the apparatus is
used as intended.
CRITERION B
The apparatus shall continue to operate as intended after the test. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended.
CRITERION C
Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by
the operation of the controls.
Test Report ------------------------------------------------------------------------------- 19/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-2 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 20/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 5 Radio Frequency Immunity Test
RS Test information: Test setup: Fully anechoic chamber, According to EN 61000-4-3 Radiated Immunity Test Setup
Test levels: (Apply Level 1, 2 and 3)
Level Test Field Strength (V/m)
1 1 2 3 3 10 X Special
NOTE: the “X” is an open test level. This level may be given in the product specification.
Test Report ------------------------------------------------------------------------------- 21/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test Frequency: 80 ~ 1000 MHz, 10V/m 1400 ~ 2000 MHz, 3V/m 2000 ~ 2700 MHz, 1V/m Modulation: FM % 80% AM Modulation with 1KHz Step size: ≦1% step size Sweep time: 2.5 Second for each frequency Test mode: Refer to test method of Chapter 1 Test instruments: Name Model Number Serial Number Selected Amplifier Research RF Amplifier (0.8 – 3GHz)
15S1G3 305899 X
Amplifier Research 40dB Attenuator
DC7144 305930 X
Mini-Circuits RF Amplifier (20 – 500MHz)
LZT-1 N/A X
Mini-Circuits RF Amplifier (500 – 1GHz)
LZT-2 N/A X
EMCO Bi-log Antenna
3141 9711-1075 X
TRC Horn Antenna
HA0501-05 RS-01 X
HP Signal Generator
8648D 3613A00117 X
HP Power Meter
E4418B GB39291240 X
WG radiation meters
EMC-20 BN2244129 X
WG E-filed
2244 / 90.20 Z-0001 X
GW DC Power Supply
GPR-3520HD A150114 X
Test Report ------------------------------------------------------------------------------- 22/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Comment: Performance Criteria ( X ) A ( ) B ( ) C General performance criteria of EMS: CRITERION A
The apparatus shall continue to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the apparatus is
used as intended.
CRITERION B
The apparatus shall continue to operate as intended after the test. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended.
CRITERION C
Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by
the operation of the controls.
Test Report ------------------------------------------------------------------------------- 23/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-3 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 24/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 6 Electric Fast Transient/Burst Requirements Test
EFT Test information: General test set-up for laboratory type tests:
> 0.25 m
> 0.25 m
EUT
EUT
AC mains supply
EUT
EFT/B- generator
Coupling / decoupling network (A)
Non-metallic table
EUT
0.1 m
Reference plane
EFT/B- generator (B)
0.1 m
AC mains supply Capacitive
coupling clamp
Grounding connectionaccording to the manufacturer’s specification. Length to be specified in the test plan.
Insulating support
Referenceplane
(L)
(L) = length between clamp and EUT to be tested, should not be more than 1-meter
(A) = location for supply line coupling (B) = location for signal lines coupling
(L)
> 0.25 m
> 0.25 m
Test Report ------------------------------------------------------------------------------- 25/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test levels: (Apply Level 3)
Open-circuit output test voltage (±10%) and repetition rate of the impulses (±20%) On power supply port, PE On input/output signal, data and
control ports Level
Voltage peak kV
Repetition rate kHz
Voltage peak kV
Repetition rate kHz
1 0.5 5 0.25 5 2 1 5 0.5 5 3 2 5 1 5 4 4 2.5 2 5 X Special Special Special Special
NOTE: the “X” is an open level. The level has to be specified in the dedicated equipment specification
Test setup: According to EN 61000-4-4 Test Voltage: DC Power line 0.5 KV, 5 KH AC Power line 2.0 KV, 5 KHz
Signal & Control line 0.5 KV, 5 KHz 1.0 KV, 5 KHz Polarity: Positive Negative Test Duration: 1 minute 3 minutes Connected lines: Power line shielded Power line non-shielded Signal & Control line non-shielded Signal & Control line shielded
Test Report ------------------------------------------------------------------------------- 26/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test mode: Ref. Test method of Chapter 1. Test instrument: Name Model Number Serial Number Selected Best Plus BURST ESD SURGE TRANSIENTS
Best Plus V6.2 199749-019SC
KeyTek Instrument EFT Test system
E412 9505206/505207 X
BEST EMC Test Instrument
BEST EMC V2.3 (-8, -9)
199918-006SC
Comment: Performance Criteria ( ) A ( X ) B ( ) C General performance criteria of EMS: CRITERION A
The apparatus shall continue to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the apparatus is
used as intended.
CRITERION B
The apparatus shall continue to operate as intended after the test. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended.
CRITERION C
Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by
the operation of the controls.
Test Report ------------------------------------------------------------------------------- 27/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-4 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 28/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 7 Surge Immunity Test
Surge Test information: Test setup: According to EN 61000-4-5 Test levels: (Apply Level 2 and Level 3)
Level Test Field Strength (kV)
1 0.5 2 1.0 3 2.0 4 4.0 X Special
NOTE: the “X” is an open class. This level may be specified in the product specification.
Coupling Line Voltage(kV) Polarity Coupling Method Load (ohm) L-N 1 Positive./Negative Capacitive 2
L-N to Ground 2 Positive./Negative Capacitive 12 LAN 1 Positive./Negative Capacitive 42
Ground Reference Plane
Surge Immunity Test (KeyTek Pulsed-EMI Test System)
0.8m
EUT
PC System Monitor
Ethernet LAN System
Simulator
Test Report ------------------------------------------------------------------------------- 29/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test Voltage: DC Power line 0.5 KV AC Power line Line – Line: 1KV Line – Ground: 2KV
Control line 0.5 KV
Signal 1 KV Voltage waveform: 1.2/50µs Current waveform: 8/20µs Polarity: Positive Negative Connected lines: Power line shielded Power line non-shielded Signal & Control line non-shielded Signal & Control line shielded Test mode: Ref. Test method of Chapter 1. Test instrument: Name Model Number Serial Number Selected Best Plus BURST ESD SURGE TRANSIENTS
Best Plus V6.2 199749-019SC
BEST EMC Test Instrument
BEST EMC V2.3 (-8, -9)
199918-006SC
KeyTek Pulsed-EMI Test System
E501B 0008260 X
KeyTek Pulsed-EMI Test System
E4552A 0008264 X
Test Report ------------------------------------------------------------------------------- 30/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Comment: Performance Criteria ( ) A ( X ) B ( ) C General performance criteria of EMS: CRITERION A
The apparatus shall continue to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the apparatus is
used as intended.
CRITERION B
The apparatus shall continue to operate as intended after the test. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended.
CRITERION C
Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by
the operation of the controls.
Test Report ------------------------------------------------------------------------------- 31/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-5 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 32/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 8 Continuous Wave Voltage Immunity Test
CS Test information: Test setup: According to EN 61000-4-6 Immunity test to RF conducted disturbances: Test levels: (Apply Level 3)
Frequency range 150kHz to 80MHz Voltage level (e.m.f.)
Level Uo [dB(µv)] Uo [V]
1 120 1 2 130 3 3 140 10 X Special
NOTE: the “X” is an open test level.
CDN Auxiliary
equipment 1 Equipment under test CDN
Auxiliary equipment 1
T
Ground reference plane 0.1 m support
RF — generator
T2
T: Termination 50ohm T2: Power attenuator
(6dB)
CDN: Coupling and decoupling network
Test Report ------------------------------------------------------------------------------- 33/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test Frequency: 0.15 ~ 80MHz Modulation: FM % 80% AM Modulation with 1KHz Step size: ≦1% Step size Signal Strength: 1Vrms 3Vrms 10Vrms Test mode: Ref. Test method of Chapter 1 Test instruments: Name Model Number Serial Number Selected FRANKONIA EMV–Mess–System
CIT-10 103A3113 X
FRANKONIA CDN
M2+M3 A3011015 X
FRANKONIA CDN
T2-801 A3010002
FRANKONIA CDN
T4-801 A3015004 X
FRANKONIA CDN
S1-801 A3005002
SCHAFFNER FM-Koppelzange
KEMZ 801 17045
Test Report ------------------------------------------------------------------------------- 34/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Comment: Performance Criteria ( X ) A ( ) B ( ) C General performance criteria of EMS: CRITERION A
The apparatus shall continue to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the apparatus is
used as intended.
CRITERION B
The apparatus shall continue to operate as intended after the test. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended.
CRITERION C
Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by
the operation of the controls.
Test Report ------------------------------------------------------------------------------- 35/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-6 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 36/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 9 Power Frequency Magnetic Field Immunity Test
PFMF Test information: Test setup: According to EN 61000-4-8 Testing site: Temperature : 23° C Humidity : 64 % RH Test setup: According to EN 61000-4-8 Test method : ( X ) Continuous ( ) Short duration Magnetic Field Strength: ( ) 1A/m ( ) 10A/m ( X ) 100A/m Frequency: 50Hz polarization: ( X ) X polarization ( X ) Y polarization ( X ) Z polarization Test mode: Ref. Test method of Chapter 1 Test Duration: ( X ) 30 seconds ( ) 1~3 seconds Connected lines: ( ) Power line shielded ( X ) Power line non-shielded ( X ) Signal & Control line non-shielded ( ) Signal & Control line shielded ** Power Frequency Magnetic Field in the horizontal and vertical polarity.** Test instruments: Name Model Number Serial Number Selected Partner EMS Tester
Transienter-1000 PIO X
EMC Partner EUT-Power Transient-1000
MF1000-1-75 X
Comment: Performance Criteria: ( X ) A ( ) B ( ) C Test Result : Pass
Test Report ------------------------------------------------------------------------------- 37/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-8 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 38/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 10 Voltage DIP / Interruption Test DIP Test information: Test setup: According to EN 61000-4-11 Voltage dips: 100% , 1 Period 30% , 25 Period 60% , 10 Period Voltage interruptions: 100% , 250 Periods Test mode: Ref. Test method of Chapter 1 Test instruments: Name Model Number Serial Number Selected Best Plus BURST ESDSURGE TRANSIENTS
Best Plus V6.2 199749-019SC
BEST EMC Test Instrument
BEST EMC V2.3 (-8, -9)
199918-006SC
Partner EMS Tester
Transienter-1000 PIO X
Test Report ------------------------------------------------------------------------------- 39/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Comment: Performance Criteria: Dips (1) 100% ( ) A ( X ) B ( ) C Dips (2) 30% ( ) A ( ) B ( X ) C Dips (3) 60% ( ) A ( ) B ( X ) C Interruptions (1) 100% ( ) A ( ) B ( X ) C General performance criteria of EMS: CRITERION A
The apparatus shall continue to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the apparatus is
used as intended.
CRITERION B
The apparatus shall continue to operate as intended after the test. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended.
CRITERION C
Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by
the operation of the controls.
Test Report ------------------------------------------------------------------------------- 40/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
EN 61000-4-11 PHOTO OF TEST SET-UP
Test Report ------------------------------------------------------------------------------- 41/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 10 Harmonics Test Test information: Test setup: According to EN 61000-3-2 Test Item: Quasi – stationary & Fluctuating Current Harmonics Test. Test mode: Ref. Test method of Chapter 1 Test instrument: Name Model Number Serial Number Harmonic/ Flicker Test System
HP 6843A 3531A-00227
Test Equipment Settings: Quasi-stationary Current
Harmonics Test Fluctuating Current Harmonics Test
Line Voltage 230VAC
230VAC
Line Frequency 50Hz
50Hz
Device Class A
A
Test Limit Overrides None
None
Total Number of Failures None
None
Total Number of Errors None
None
Test Result: Pass
Test Report ------------------------------------------------------------------------------- 42/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 11 Voltage Fluctuation and Flicker Test
Test information: Test setup: According to EN 61000-3-3 Test mode: Ref. Test method of Chapter 1 Test instrument: Name Model Number Serial Number Harmonic/Flicker Test System
HP 6843A 3531A-00227
Test Equipment Settings Line Voltage
230VAC
Line Frequency
50Hz
Test Limit Overrides
None
Total Number of Failures
Pst: (0), Plt: (0) Dc: (0), Dmax (0), Dt (0)
Total Number of Errors
None
Test Result: Pass
Test Report ------------------------------------------------------------------------------- 43/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Appendix A Test Result of Conducted Emissions for Mains power
Testing room : Temperature : 25 ° C Humidity : 73 % RH Line 1
READING AMPLITUDE LIMIT Frequency
(kHz) Peak
(dBµV) Quasi-Peak
(dBµV) Average (dBµV)
Quasi-Peak(dBµV)
Average (dBµV)
Margin
(dB)
191.000 50.19 --- --- 79.00 66.00 -15.81317.000 46.74 --- --- 79.00 66.00 -19.26572.000 45.08 --- --- 73.00 60.00 -14.92
1334.000 45.38 --- --- 73.00 60.00 -14.622208.000 47.50 --- --- 73.00 60.00 -12.503040.000 47.58 --- --- 73.00 60.00 -12.424688.000 47.53 --- --- 73.00 60.00 -12.477360.000 42.51 --- --- 73.00 60.00 -17.49
24120.000 33.12 --- --- 73.00 60.00 -26.88
Line 2 READING AMPLITUDE LIMIT
Frequency (kHz)
Peak (dBµV)
Quasi-Peak(dBµV)
Average (dBµV)
Quasi-Peak(dBµV)
Average (dBµV)
Margin
(dB)
150.000 52.20 --- --- 79.00 66.00 -13.80191.000 50.25 --- --- 79.00 66.00 -15.75317.000 48.69 --- --- 79.00 66.00 -17.31
1012.000 44.92 --- --- 73.00 60.00 -15.081837.000 46.93 --- --- 73.00 60.00 -13.073040.000 47.42 --- --- 73.00 60.00 -12.584688.000 46.70 --- --- 73.00 60.00 -13.307360.000 43.47 --- --- 73.00 60.00 -16.53
29420.000 33.48 --- --- 73.00 60.00 -26.52
Note: 1. The reading amplitudes are all under limit. 2. Testing result = Amplitude reading + Correction factor (Insertion loss of LISN, Cable loss,
Attenuator, Amplifier and so on)
Test Report ------------------------------------------------------------------------------- 44/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test Result of Conducted Emission for Telecommunication
Testing room : Temperature : 25.0 ° C Humidity : 73.0 % RH 10Mbps
READING AMPLITUDE LIMIT Frequency
(KHz) Peak
(dBµV) Quasi-Peak
(dBµV) Average (dBµV)
Quasi-Peak(dBµV)
Average (dBµV)
Margin
(dB)
187.000 41.75 --- --- 95.94 82.94 -41.19250.000 36.30 --- --- 94.14 81.14 -44.84504.000 42.85 --- --- 87.00 74.00 -31.15
1437.000 50.59 --- --- 87.00 74.00 -23.411924.000 48.01 --- --- 87.00 74.00 -25.993004.000 42.38 --- --- 87.00 74.00 -31.628610.000 48.10 --- --- 87.00 74.00 -25.90
12250.000 42.48 --- --- 87.00 74.00 -31.5215270.000 36.35 --- --- 87.00 74.00 -37.65
100Mbps
READING AMPLITUDE LIMIT Frequency
(KHz) Peak
(dBµV) Quasi-Peak
(dBµV) Average (dBµV)
Quasi-Peak(dBµV)
Average (dBµV)
Margin
(dB)
191.000 41.82 --- --- 95.83 82.83 -41.01366.000 46.10 --- --- 90.83 77.83 -31.73622.000 46.83 --- --- 87.00 74.00 -27.17
1017.000 53.60 --- --- 87.00 74.00 -20.401503.000 51.86 --- --- 87.00 74.00 -22.143030.000 54.70 --- --- 87.00 74.00 -19.305240.000 56.65 --- --- 87.00 74.00 -17.357930.000 54.84 --- --- 87.00 74.00 -19.16
16160.000 62.92 --- --- 87.00 74.00 -11.0823120.000 63.05 --- --- 87.00 74.00 -10.95
Test Report ------------------------------------------------------------------------------- 45/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Appendix B Test Conditions: Testing room : Temperature : 25 ° C Humidity : 73 % RH Testing site : Temperature : 25 ° C Humidity : 73 % RH Test Result of Radiated Emission for Horizontal
Frequency Reading Amplitude
Ant. Height
Table
Correction Factors
Corrected Amplitude
Class A Limit
Margin
MHz dBµV m degree dB/m dBµV/m dBµV/m dB
250.0070 38.20 3.57 0 -4.95 33.25 47.00 -13.75
331.7640 37.87 1.00 46 -1.81 36.06 47.00 -10.94
500.0150 30.75 2.27 0 2.91 33.66 47.00 -13.34
600.4280 33.76 2.41 327 5.86 39.62 47.00 -7.38 Test Result of Radiated Emission for Vertical
Frequency Reading Amplitude
Ant. Height
Table
Correction Factors
Corrected Amplitude
Class A Limit
Margin
MHz dBµV m degree dB/m dBµV/m dBµV/m dB
120.0010 37.57 1.00 137 -7.26 30.31 40.00 -9.69
145.9220 35.77 1.00 124 -4.72 31.05 40.00 -8.95
196.1960 36.90 3.63 0 -6.57 30.33 40.00 -9.67
596.9610 33.68 2.80 74 5.75 39.43 47.00 -7.57
940.8420 28.84 3.94 0 11.17 40.01 47.00 -6.99
Note: 1. Margin = Amplitude – limit, if margin is minus means under limit. 2. Corrected Amplitude = Reading Amplitude + Correction Factors 3. Correction factor = Antenna factor + (Cable Loss – Amplitude gain) + Switching Box Loss
Test Report ------------------------------------------------------------------------------- 46/55
Report No.: M47CE061207 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Appendix C
Photographs of EUT
External Photos of EUT ------------------------------------------------------------ 47/55
External Photos of EUT ------------------------------------------------------------ 48/55
Power Supply of EUT --------------------------------------------------------------- 49/55
Internal Photos of EUT ------------------------------------------------------------- 50/55
Internal Photos of EUT ------------------------------------------------------------- 51/55
Internal Photos of EUT ------------------------------------------------------------- 52/55
Internal Photos of EUT ------------------------------------------------------------- 53/55
Internal Photos of EUT ------------------------------------------------------------- 54/55
Internal Photos of EUT ------------------------------------------------------------- 55/55