certificate of approval no cf 5204 - warrington ... uk ltd international house, millfield lane,...
TRANSCRIPT
This certificate is the property of Exova (UK) Limited trading as Warrington Certification Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
Signed and sealed for and on behalf of Exova (UK) Limited trading as Warrington Certification
Paul Duggan Certification Manager
CERTIFICATE OF APPROVAL No CF 5204
This is to certify that, in accordance with
TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of
1
Page 1 of 74
PYROGUARD UK LTD
International House, Millfield Lane, Haydock, WA11 9GA Tel: 01942 710720 Fax: 01942 710730
Have been assessed against the requirements of the Technical Schedule(s)
denoted below and are approved for use subject to the conditions appended hereto:
_____________________________________________________________________________________________________
CERTIFIED PRODUCT TECHNICAL SCHEDULE
‘Pyroguard T EI’ Insulating Fire Resisting Glass
TS 25 Fire Resistant Glass, Glazing Systems and Materials
Issued: 24th February 2014
Revised: 7th November 2017
Valid to: 23rd
February 2019
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 2 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI Insulating Fire Resisting Glass
This Certificate of Approval relates to the fire resistance of Pyroguard UK Ltd. ‘Pyroguard T Insulating’ laminated glass products when used in the following applications, as defined in BS 476: Part 22: 1987 but using test results achieved against the following Standards - BS EN 1363-1 Fire Resistance Tests, BS EN 1364-1 Fire Resistance Tests on Doors, Shutters and Openable Windows or BS 1364-3 Fire Resistance Tests for Non Loadbearing Elements – Curtain Walling This product is approved on the basis of: a) Initial type testing b) A design appraisal against TS25 c) Product surveillance under BS EN ISO 9001: 2008 d) Audit testing e) Inspection and surveillance of factory production control
Glass Specification
Application
Fire Resistance Performance (mins) Page
No. Integrity Insulation
Pyroguard T EI30/18-1 or 18-2
Multiple paned Timber framed screens 30 30 6
Pyroguard T EI60/21-1 & 25-3 (inc.
V1 options)
Multiple paned Single and IGU Timber framed screens
60 60 8
Pyroguard T EI30/18-1 or 18-2
Multiple paned Timber framed screens 30 30 10
Pyroguard T EI30/18-1 or 18-2
Timber Doorsets 30 30 12
Pyroguard T EI30/18-1 or 18-2
Multiple paned Single Steel framed screens 30 30 14
Pyroguard T EI30/18-1 or 18-2
Multiple paned Steel framed screens 30 30 16
Pyroguard T EI30/18-1 or 18-2
Multiple paned Steel framed screens 60 30 18
Pyroguard T EI30/18-1 or 18-2
Multiple paned Steel framed screens 60 30 20
Pyroguard T EI90/32-2
Two paned Steel framed screens 60 60 22
Pyroguard T EI90/32-2
Multiple paned Steel framed screens 60 60 24
Pyroguard T EI90/32-2
Multiple paned Steel framed screens 90 90 26
Pyroguard T EI90/32-2
Two paned Steel framed screens 90 90 28
Pyroguard T EI120/47-3
Multiple paned Steel framed screens 120 120 30
Pyroguard T EI60/25-3
Single glazed into steel doors 60 60 32
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 3 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI Insulating Fire Resisting Glass (continued)
Glass Specification Application Fire Resistance Performance (mins)
Page No.
Integrity Insulation
*Pyroguard T EI30/18-1VI or 18-2VI
Multiple panes of IGU in frame and in two Steel doors
30 30 34
*Pyroguard T EI30/18-1VI or 18-2VI
Multiple panes of IGU in frame and in two Steel doors
60 30 36
Pyroguard T EI30/18-1VI or 18-2VI
Multiple paned IGU Timber framed screens
30 30 38
*Pyroguard T EI30/18-1VI or 18-2VI
IGUs in multiple paned Timber framed screens
60 30 40
*Pyroguard T EW30/13-1 VI
IGUs in multiple paned Steel framed screens
30 30 42
Pyroguard T EW30/13-1 VI
IGUs in multiple paned Steel framed screens
60 30 44
*Pyroguard T EI30/13-1 VI
IGUs in multiple paned Steel framed screens
60 30 46
*Pyroguard T EI60/25-3VI
IGUs in multiple Steel framed screen 60 60 48
*Pyroguard T EW30/13-1 VI
IGUs in multiple paned Steel framed screens
90 30 50
*Pyroguard T
EI30/18-1 or 18-2VI
IGUs in multiple paned Steel framed screens
30 30 52
*Pyroguard T
EI90/32-2VI
IGUs in multiple paned Steel framed screens
60 60 54
*Pyroguard T
EI90/32-2VI
IGUs in multiple paned Steel framed screens
90 90 56
*Pyroguard T EI30/18-1VI or 18-2VI
IGUs in multiple paned Steel framed screens
60 30 58
Pyroguard T SWS EI30/32-2
Four single Butt jointed panes in timber framed screens
30 30 60
Pyroguard T SWS EI60/40 and EI60/36-2
Three single Butt jointed panes in timber framed screens
60 60 62
Pyroguard T SWS
EI30/24-2
Three single Butt jointed panes in Steel framed screens
30 30 64
Pyroguard T EI30/18-1 or 18-2
(inc. VI and VF variants)
Aluprof MB 78 EI Aluminium Screens 30 30 66
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 4 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI Insulating Fire Resisting Glass (continued)
Glass Specification Application Fire Resistance Performance (mins)
Page No.
Integrity Insulation
Pyroguard T EI30/18-1 or 18-2 (inc. VI variant)
Aluprof MB 78 EI Aluminium Doorsets 30 30 69
Pyroguard T EI30/25-3 and 25-3VI
Aluprof MB 78 EI Aluminium Screens 60 60 71
Pyroguard T EI30/25-3VI
Aluprof MB 78 EI Aluminium Doorsets 60 60 74
Note* The fire resistant pane of the IGU construction can be used as a single glazed pane in any previously fire tested or CERTIFIRE approved system. Note: In this case the product code will change.
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 5 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI Insulating Fire Resisting Glass
General Requirements
Where the glass is installed in a timber or steel framed screen, the orientation of the screen shall be no more than ±10º from the vertical. The edge cover to each pane is normally a minimum of 12 mm minimum. See test reports for exact dimensions. Options
Can be etched or sandblasted on one glass face. Self - adhesive films/foils may be applied to either glass surface. Insulating Glass Units (IGUs) may incorporate fixed aluminium blinds or Georgian bars within the cavity between the inner and outer glass layers. Note:
Where IGUs are approved and the fire resistant pane is glazed to the non-fire side, the non-fire resistant glass on the fire side can be float, toughened or laminated glass. When the fire resistant pane is glazed to the fire side the non-fire resistant glass on the non-fire side can be any pane that does not contain a flammable organic material i.e. float glass or toughened glass but not a laminated or painted glass unless supported by test evidence not contained in this CF. Where a fire resistant IGU is required it can be manufactured from any single size glass listed in this certificate for a given fire performance. The IGU should be glazed into any previously fire tested or CERTIFIRE approved system. Within this certification IGU airspace widths can vary different products. For larger airspace widths please contact the owner of this Certification. The fire resistant pane of the IGU construction can be used as a single glazed pane in any previously fire tested or CERTIFIRE approved system. For doors described in this Certificate then the glazed element can also be used in any previously fire tested or CERTIFIRE approved glazed insulated steel or timber framed door. Additional non fire rated glass can be laminated to the fire glass but must be installed to the fire side.
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 6 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in Hardwood framed screens for periods of 30 minutes integrity and insulation
For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved framing system utilising the following basic specification:
Framework from Hardwood (e.g. Oak) and 90 mm by 50 mm section. Transoms and mullions assembled by steel screws 10 x 135 mm.
Hardwood beads 33 mm by 20 mm fixed with 3.5 x 45 mm screws.
Glazing and frame details as describe in Efectis test report No 271-37090 and WF343243
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 7 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in Hardwood framed screens for periods of 30 minutes integrity and insulation (Continued) This Certificate of Approval relates to the sizes 18 mm thick Pyroguard T EI30/18-1 or 18-2 shown in Figure 1 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 1. Maximum Permitted Glass Dimensions
500 1000 1500 2000 2500 1495 1869
3000
2500
2000
1500
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
2495
Maximum Area 4.66m2
3119
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 8 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI60/21-1 or 25-3 glass (inc. VI variants) in hardwood frame for periods of 60 minutes integrity and 60 minutes insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved timber framing system utilising the following basic specification:
Frame: from softwood with minimum density 530kg/m3 (see below and test report for
dimensions) Beads: from softwood with minimum density 530kg/m
3 (see below and test report for
dimensions) Glass edge intumescent seal: Kerafix ceramic tape: 20x4mm thick capped with Firestp
700 for single glazed option. 15x3mm capped with Flexilodice BS for VI option. Aperture liner: Odice Flexilodice. 20x3mm thick for single glazed option. 40x2mm for VI
option. Glazing and frame details as describe in WF379049
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 9 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI60/21-1 or 25-3 glass (inc. VI variants) in hardwood frame for periods of 60 minutes integrity and 60 minutes insulation (Continued) The timber framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of Pyroguard T EI30/21-1 or 25-3 or Pyroguard T EI30/21-1 or 25-3 VI shown in Figure 2 and 3 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
2600 3146
Glass Height
(mm)
Glass Width (mm)
Towards 0
Maximum Area 4.7m
2
1815
1500
Figure 2. Maximum Permitted Glass
Dimensions
Pyroguard T EI30/18-1 or 18-2
2600 3250
Glass Height
(mm)
Glass Width (mm)
Towards 0
Maximum Area 4.2m
2
1622
1298
Figure 3. Maximum Permitted Glass
Dimensions
Pyroguard T EI30/18-1 VI or 18-2 VI
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 10 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in Softwood framed screens for periods of 30 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved framing system utilising the following basic specification:
Frame: from softwood with minimum density 450kg/m3 (see below and test report for
dimensions) Beads: from hardwood with minimum density 650kg/m
3 (see below and test report for
dimensions) fixed with 50 mm steel pins at 150 mm centres, 30° to glass Glass edge intumescent seal: Interdens, 15 mm x 2 mm Non-combustible setting blocks Glazing and frame details as describe in WF343243
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 11 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in Softwood framed screens for periods of 30 minutes integrity and insulation (Continued) This Certificate of Approval relates to the sizes 18 mm thick Pyroguard T EI30/18-1 or 18-2 shown in Figure 4 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
1555 1943
Glass Height
(mm)
Glass Width (mm)
Towards 0
Maximum Area 5.0m
2
3237
2590
Figure 4. Maximum Permitted Glass
Dimensions
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 12 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in timber Doorsets for periods of 30 minutes integrity and insulation
For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved framing doorset utilising the following basic specification:
Timber door leaf (softwood or hardwood with a minimum density of 477kg/m3) – 56
mm minimum thickness (Item 4 on drawing below)
Softwood or hardwood beads 33 mm by 25 with 17 mm by 10 mm rebate fixed with 1.7 mm x 50 mm pins at 150 mm centres fixed at 45° (Item 10)
2 mm thick by 15 mm wide Lorient Polyproducts Ltd LP1502 Interdens glazing
gaskets fitted between bead and glass (Item 9)
Glazing and doorset details as described in WF Test Report No. 356228
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 13 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in timber doorset for periods of 30 minutes integrity and insulation (Continued) This Certificate of Approval relates to the sizes 18 mm thick Pyroguard T EI30/18-1 or 18-2 shown in Figure 5 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 5 Maximum Permitted Glass Dimensions
841 1051
Glass Height
(mm)
Glass Width (mm)
Towards 0
2235
Maximum Area 1.88m2
2793
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 14 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in steel framed screens for periods of 30 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in IFT test report No 11-000423
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 15 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in steel framed screens for periods of 30 minutes integrity and insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of 18 mm thick Pyroguard T EI30/18-1 or 18-2 shown in Figure 6 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
1284
1868
Figure 6. Maximum Permitted Glass Dimensions
1500 2000 2500 3000 3500 1264 1580 2594 3243
2500
2000
1500
1000
500
Glass Height
(mm)
Glass Width (mm)
Towards 0
1494
Maximum Area 4.16m2
1605
Maximum Area 2.36m2
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 16 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in steel framed screens for periods of 30 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in Efectis test report No 271-44217 and EFR-13-V-131496
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 17 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in steel framed screens for periods of 30 minutes integrity and insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of 18 mm thick Pyroguard T EI30/18-1 or 18-2 shown in Figure 7 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
1494
Maximum Area 2.37m2
1868
Figure 7. Maximum Permitted Glass Dimensions
1500 2000 2500 3000 3500 1269 1586 2594 3243
2500
2000
1500
1000
500
Glass Height
(mm)
Glass Width (mm)
Towards 0
1284
Maximum Area 4.16m2
1605
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 18 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in steel framed screens for periods of 60 minutes integrity and 30 Minutes insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in Efectis test report No 271-44217 and EFR-13-V-131496
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 19 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in steel framed screens for periods of 60 minutes integrity and 30 Minutes insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes 18 mm thick Pyroguard T EI30/18-1 or 18-2 shown in Figure 8 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 8. Maximum Permitted Glass Dimensions
1500 2000 2500 3000 3500 1269 2594 2680 1311
2500
2000
1500
1000
500
Glass Height
(mm)
Glass Width (mm)
Towards 0
1284
Maximum Area 3.44m2
1326
1543
1494
Maximum Area 1.96m2
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 20 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in steel framed screens for periods of 60 minutes integrity and 30 minutes insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in IFT test report No 11-000423
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 21 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 glass in steel framed screens for periods of 60 minutes integrity and 30 minutes insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of 18 mm thick Pyroguard T EI30/18-1 or 18-2 shown in Figure 9 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
1284
1718
Figure 9. Maximum Permitted Glass Dimensions
1264 1454 2594 2983
Glass Height
(mm)
Glass Width (mm)
Towards 0
1494
Maximum Area 3.83m2
1477
Maximum Area 2.17m2
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 22 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI 90/32-2 glass in steel framed screen for periods of 60 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in IFT test report No271-35263
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 23 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI 90/32-2 glass in steel framed screen for periods of 60 minutes integrity and insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes with 32 mm thick Pyroguard T EI90/32-2 shown in Figure 10 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 10. Maximum Permitted Glass Dimensions
1500 1600 1700 1800 1900 1875
5000
4000
3000
2000
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
Maximum Area 5.31 m2
2834
3543
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 24 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI 90/32-2 glass in steel framed screen for periods of 60 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in IFT test report No271-35924
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 25 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI 90/32-2 glass in steel framed screen for periods of 60 minutes integrity and insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes with 32 mm thick Pyroguard T EI90/32-2 shown in Figure 11 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 11. Maximum Permitted Glass Dimensions
1000 1500 2000 3500 4000 2824 3530
2000
1750
1500
1250
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
Maximum Area 5.3 m2
1875
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 26 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI90/32-2 glass in steel framed screen for periods of 90 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in IFT test report No271-35924
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 27 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI90/32-2 glass in steel framed screen for periods of 90 minutes integrity and insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of 32 mm thick Pyroguard T EI90/32-2 shown in Figure 12 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 12. Maximum Permitted Glass Dimensions
1000 1500 2000 3500 4000 2824
2000
1750
1500
1250
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
Maximum Area 4.24 m2
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 28 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI90/32-2 glass in steel framed screen for periods of 90 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in IFT test report No271-35263
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 29 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI90/32-2 glass in steel framed screen for periods of 90 minutes integrity and insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of 32 mm thick Pyroguard T EI90/32-2 shown in Figure 13 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 13. Maximum Permitted Glass Dimensions
1500 1600 1700 1800 1900
5000
4000
3000
2000
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
Maximum Area 5.1 m2
2834
3401
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 30 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T Interfire EI 120/47-3 glass in steel framed screen for periods of 120 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in Efectis test report No 08-V-437
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 31 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T Interfire EI 120/47-3 glass in steel framed screen for periods of 120 minutes integrity and insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes with 47 mm thick Pyroguard T EI120/47-3 shown in Figure 14 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
1379
1724
Figure 14. Maximum Permitted Glass Dimensions
1000 1100 1200 1300 1400
3000
2500
2000
1500
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
Maximum Area 3.67m2
2825
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 32 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI60/25-3 glass in steel framed doors for periods of 60 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel framing doors system which have achieved 60 minutes integrity and insulation in accordance with BS 476: Part 22: 1987, utilising the following basic specification:
Glazing and frame details as describe in IFT test report No 271 41119
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 33 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI60/25-3 glass in steel framed doors for periods of 60 minutes integrity and insulation The insulated steel framing doors system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of single glazed 25 mm thick Pyroguard T EI60/25-3 shown in Figure 15 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 15. Maximum Permitted Glass Dimensions
761 913
Glass Height
(mm)
Glass Width (mm)
Towards 0
2329
Maximum Area 2.13 m2 2795
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 34 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 VI glass in steel framed doors for periods of 30 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel framing doors system utilising the following basic specification:
Glazing and frame details as describe in Efectis test report No 11-V-693
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 35 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 VI glass in steel framed doors for periods of 30 minutes integrity and insulation (Continued) The insulated steel framing doors system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of IGU of 35 mm thick Pyroguard T EI30/18-1 or 18-2 VI shown in Figure 16 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 16. Maximum Permitted Glass Dimensions
1000 1100 1200 1300 1400 1029 1286
3500
3000
2500
2000
1500
Glass Height
(mm)
Glass Width (mm)
Towards 0
2684
Maximum Area 3.45 m2 3355
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 36 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 VI glass in steel framed doors for periods of 60 minutes integrity and 30 minutes insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel framing doors system utilising the following basic specification:
Glazing and frame details as describe in Efectis test report No 11-V-693
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 37 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 VI glass in steel framed doors for periods of 60 minutes integrity and 30 minutes insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of IGU of 35 mm thick Pyroguard T EI30/18-1 or 18-2 VI shown in Figure 17 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 17. Maximum Permitted Glass Dimensions
700 800 900 1000 1100 1029
3500
3000
2500
2000
1500
Glass Height
(mm)
Glass Width (mm)
Towards 0
2684
Maximum Area 2.76 m2
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 38 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 VI glass in hardwood frame for periods of 30 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved timber framing system utilising the following basic specification:
Intumecent seal between non fire glass and bead, 25 by 1.5mm Intumex (Odice) or (Flexpress 100 (Gluske) or 20 by 3 mm Fibrefrax FT paper (GLUSKE) or superwool(Odice).
Glazing and frame details as describe in Efectis test report No 09-V-481 and
WF343243
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 39 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 VI glass in hardwood frame for periods of 30 minutes integrity and insulation (Continued) The insulated timber framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of IGU of 35 mm thick Pyroguard T 30/18-1 or 18-2 VI shown in Figure 18 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 18. Maximum Permitted Glass Dimensions
1500 2000 2500 3000 3500 2585 3231
2500
2000
1500
1000
500
Glass Height
(mm)
Glass Width (mm)
Towards 0
1856
Maximum Area 4.8 m2
1485
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 40 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 VI glass in hardwood frame for periods of 60 minutes integrity and 30 minutes insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved timber framing system utilising the following basic specification:
Intumecent seal between non fire glass and bead, 25 by 1.5mm Intumex (Odice) or (Flexpress 100 (Gluske) or 20 by 3 mm Fibrefrax FT paper (GLUSKE) or superwool(Odice).
Glazing and frame details as describe in Efectis test report No 09-V-481 and
WF343243
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 41 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 VI glass in hardwood frame for periods of 60 minutes integrity and 30 minutes insulation (Continued) The insulated timber framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of IGU of 30 mm thick Pyroguard T EI30/18-1 or 18-2 VI shown in Figure 19 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 19. Maximum Permitted Glass Dimensions
1500 2000 2500 3000 3500 2585 2628
2500
2000
1500
1000
500
Glass Height
(mm)
Glass Width (mm)
Towards 0
1510
Maximum Area 3.99 m2
1485
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 42 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EW30/13-1 VI glass in steel framed Curtain Walling System with glazed panels for periods of 30 minutes integrity and 30 minutes insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in Efectis test report No 007-CVB-RO495
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 43 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EW30/13-1 VI glass in steel framed Curtain Walling System with glazed panels for periods of 30 minutes integrity and 30 minutes insulation The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of IGU with 13 mm thick Pyroguard T EW30/13-1 VI shown in Figure 20 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 20. Maximum Permitted Glass Dimensions
500 1000 1500 2000 2500 1875
4000
3500
3000
2000
1500
Glass Height
(mm)
Glass Width (mm)
Towards 0
2928
Maximum Area 5.49m2
3660
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 44 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EW30/13-1 VI glass in steel framed system for periods of 60 minutes integrity and 30 minutes insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in Efectis test report No 12-V-207
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 45 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EW30/13-1 VI glass in steel framed system or Isofire 45 system for periods of 60 minutes integrity and 30 minutes insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of IGU with 26 mm thick Pyroguard T EW30/13-1 VI shown in Figure 21 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 21. Maximum Permitted Glass Dimensions
1400 1479 1494 1578
Glass Height
(mm)
Glass Width (mm)
Towards 0
Maximum Area 4.18 m2
2800
1391
1484
Maximum Area 2.19m2
2988
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 46 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EW30/13-1 VI glass in steel framed Curtain Walling System with glazed panels for periods of 60 minutes integrity and 30 minutes insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in Efectis test report No 007-CVB-RO495
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 47 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EW30/13-1 VI glass in steel framed Curtain Walling System with glazed panels for periods of 60 minutes integrity and 30 minutes insulation The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of IGU with 13 mm thick Pyroguard T EW30/13-1 VI shown in Figure 22 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 22. Maximum Permitted Glass Dimensions
500 1000 1500 2000 2500 1875
4000
3500
3000
2000
1500
Glass Height
(mm)
Glass Width (mm)
Towards 0
2928
Maximum Area 5.49m2
3660
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 48 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI60/25-3 VI glass in steel framed system for periods of 60 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in Efectis test report No 09-V-234
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 49 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI60/25-3 VI glass in steel framed system for periods of 60 minutes integrity and insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of IGU of 40 mm thick Pyroguard T EI60/25-3 VI shown in Figure 23 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 23. Maximum Permitted Glass Dimensions
1500 1600 1700 1800 1900 1415 1769
5000
4000
3000
2000
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
Maximum Area 4.99 m2
2820
3525
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 50 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EW30/13-1 VI glass in steel framed Curtain Walling System with glazed for periods of 90 minutes integrity and 30 minutes insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in Efectis test report No 007-CVB-RO495
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 51 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EW30/13-1 VI glass in steel framed Curtain Walling System with glazed panels for periods of 90 minutes integrity and 30 minutes insulation The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of IGU with 13 mm thick Pyroguard T EW30/13-1 VI shown in Figure 24 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 24. Maximum Permitted Glass Dimensions
500 1000 1500 2000 2500
3000
2500
2000
1500
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
2928
Maximum Area 4.39 m2
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 52 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 VI glass in steel framed screens for periods of 30 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in IFT test report No10-000976
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 53 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 VI glass in steel framed screens for periods of 30 minutes integrity and insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of IGU of 35 mm thick Pyroguard T EI30/18-1 or 18-2 VI shown in Figure 25 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
1372
1097
Figure 25. Maximum Permitted Glass Dimensions
1100 1300 1500 1700 1900 1484 1618 1855 1494
3000
2500
2000
1500
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
2855
Maximum Area 3.7m2
2284
Maximum Area 2.04m2
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 54 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI90/32-2 VI glass in steel framed screens for periods of 60 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in IFC test report No576
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 55 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI90/32-2 VI glass in steel framed screens for periods of 60 minutes integrity and insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of IGU of 35 mm thick Pyroguard T EI90/32-2 VI shown in Figure 26 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 26. Maximum Permitted Glass Dimensions
500 1000 1500 2000 2500 1503 1879
1500
1400
1300
1200
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
1079
Maximum Area 2.03m2
1349
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 56 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI90/32-2 VI glass in steel framed screens for periods of 90 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in IFC test report No576
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 57 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI90/32-2 VI glass in steel framed screens for periods of 90 minutes integrity and insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of IGU of 35 mm thick Pyroguard T EI90/32-2 VI shown in Figure 27 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 27. Maximum Permitted Glass Dimensions
500 1000 1500 2000 2500 1503 1804
1500
1400
1300
1200
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
1079
Maximum Area 1.95m2
1295
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 58 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 VI glass in steel framed screens for periods of 60 minutes integrity and 30 Minutes insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel system utilising the following basic specification:
Glazing and frame details as describe in IFT test report No10-000976
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 59 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 or 18-2 VI glass in steel framed screens for periods of 60 minutes integrity and 30 Minutes insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of IGU of 35 mm thick Pyroguard T EI30/18-1 or 18-2 VI shown in Figure 28 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions
2323
1097
Figure 28. Maximum Permitted Glass Dimensions
1100 1300 1500 1700 1900 1294 1484 1319 1316 1509
3000
2500
2000
1500
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
Maximum Area 3.01m2
2284
Maximum Area 1.66m2
1116
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 60 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/32-2 SWS Butt Jointed Glass in hardwood frame for periods of 30 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved timber framing system utilising the following basic specification:
Hardwood frame with a density of 650 kg/m3 and 107 mm by 38 mm section. Assembled
in the construction with dowels and screws 10 x 160 mm every 900 mm. Double hardwood beads 35 mm by 20 mm fixed by screws 4 x 60 mm every 170 mm at angle of 30
0 degrees around the framework 30 x 2 mm Flexpress intumescent strip.
Glazing material Kerafix 2000 mineral fibre 20 x 3 mmat glazed edges. Fire Resistant
Sealant at butt joint between glass junction 30 mm wide.
80 by 6 mm Promatect H or Flammi 12(GLUSKE) setting blocks and Bottom edge clearance 6 mm, edge cover 14mm
Intumecent seal between non fire glass and bead, 25 by 1.5mm Intumex (Odice) or
(Flexpress 100 (Gluske) or 20 by 3 mm Fibrefrax FT paper (GLUSKE) or superwool(Odice)
Glazing and frame details as describe in Efectis test report No 09-V-241
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 61 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/32-2 SWS Butt Jointed Glass in hardwood frame for periods of 30 minutes integrity and insulation (Continued) The insulated timber framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of 32 mm thick Pyroguard T EI30/32-2 SWS shown in Figure 29 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 29. Maximum Permitted Glass Dimensions
1500 2000 2500 3000 3500 1830 2288
5000
4000
3000
2000
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
2900
Maximum Area 6.63 m2
3625
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 62 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI60/40-2 and EI60/36-2 SWS Butt Jointed Glass in hardwood frame for periods of 30 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved timber framing system utilising the following basic specification:
40 mm thick fire glass Pyroguard T EI60/40-2 SWS with 2 x 11 mm safety glass with 5.5.2 construction/2 x 6 mm intumescent interlayer/6 mm float glass, symmetrical glass construction with glazing beads on both side.
Alternatively constructed with 4.4.2 safety glass construction to give 36 mm thick fire
glass Pyroguard T EI60/36-2 SWS.
Glazing and frame details as describe in Efectis test report No 08-V-295
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 63 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI60/40-2 and EI60/36-2 SWS Butt Jointed Glass in hardwood frame for periods of 30 minutes integrity and insulation (Continued) The insulated timber framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of 40mm or 36 mm thick Pyroguard T EI60/40-2 SWS or Pyroguard T EI60/36-2 shown in Figure 30 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 30. Maximum Permitted Glass Dimensions
500 1000 1500 2000 2500 1830
3000
2500
2000
1500
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
2900
Maximum Area 5.31 m2
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 64 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/24-2 SWS Butt Jointed Glass in steel partition system for periods of 30 minutes integrity and insulation. For this application the following conditions shall apply: The glass shall be glazed within a previously fire tested or CERTIFIRE approved insulated steel partition system utilising the following basic specification:
Glazing with a double bead system 15 x 20 mm on the fire side and 20 x 20 mm non fire side, screw fixed every 300 mm with 20 mm by 3 mm Flexlit Kerafix ceramic glazing (Gluske) tape. Thinnest beads on fire side.
The butt joints of the glazing were assembled side by side with 24 mm by 5 mm fire
resistant silicone. Along the top of all glazing, Kerafix Silicone (GLUSKE) was applied on the unexposed side.
Clearance between glass and frame was 7.5 mm. Edge Cover was 12.5 mm.
Glazing and frame details as describe in Efectis test report No 12-V-236
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 65 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/24-2 SWS Butt Jointed Glass in steel partition system for periods of 30 minutes integrity and insulation (Continued) The insulated steel framing system shall have test evidence or be CERTIFIRE approved for the inclusion of apertures of the proposed dimensions. This Certificate of Approval relates to the sizes of Pyroguard T EI30/24-2 SWS shown in Figure 31 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Figure 31. Maximum Permitted Glass Dimensions
1000 1200 1400 1600 1800 1300 1560
4500
4000
3500
3000
2500
1000
Glass Height
(mm)
Glass Width (mm)
Towards 0
3265
Maximum Area 5.09 m2
3918
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 66 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 and 18-2 (including VI and VF Variants) within Aluprof MB-78 EI aluminium framing screen system for periods of 30 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within an Aluprof MB-78 EI aluminium framed screen asdetailled diagrammatically below. Please consult the frame manufacturer for full specification of framing system. Glazing and frame details are as described in Efectis test report No’s. EFR-14-V-003556A, EFR-14-V-003554 and EFR-14-V-003555
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 67 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 and 18-2 (including VI and VF Variants) within Aluprof MB-78 EI aluminium framing screen system for periods of 30 minutes integrity and insulation This Certificate of Approval relates to the sizes of Pyroguard T EI30/18-1 and 18-2 (including VI and VF Variants)shown in Figure 32, 33 and 34 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Glass Height
(mm)
1875
2800
Maximum Area 5.14m2
1470 1837 2385 2981
Glass Width (mm)
Towards 0
1500
3500
Maximum Area 3.58 m2
Figure 32. Maximum Permitted Glass Dimensions - Pyroguard T EI30/18-1 and 18-2
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 68 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 and 18-2 (including VI and VF Variants) within Aluprof MB-78 EI aluminium framing screen system for periods of 30 minutes integrity and insulation
Glass Height
(mm)
1625
2200
Maximum Area 3.55m2
1292 1615 2385 2981
Glass Width (mm)
Towards 0
1300
2750
Maximum Area 3.58 m2
Figure 33. Maximum Permitted Glass Dimensions - Pyroguard T EI30/18-1 VI and 18-2VI
Glass Height
(mm)
471
Maximum Area 2.84m2
1292 2866 3582
Glass Width (mm)
Towards 0
377
2200
Maximum Area 1.35 m2
Figure 34. Maximum Permitted Glass Dimensions - Pyroguard T EI30/18-1VF and 18-2VF
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 69 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 and 18-2 (including VI variant) within Aluprof MB-78 EI aluminium framed door systems for periods of 30 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within an Aluprof MB-78 EI aluminium framed doorset system as detailed diagrammatically below. Please consult the frame manufacturer for full specification and approved scope of doorset system. Glazing and frame details are as described in Efectis test report No’s. EFR-14-V-003552, EFR-14-V-003553 and EFR-15-V-003849
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 70 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI30/18-1 and 18-2 (including VI variant) within Aluprof MB-78 EI aluminium framed door systems for periods of 30 minutes integrity and insulation This Certificate of Approval relates to the sizes of Pyroguard T EI30/18-1 and 18-2 (including VI variant) shown in Figure 35 and 36 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Glass Height
(mm)
2235
Maximum Area 2.90m2
1118 1221
Glass Width (mm)
Towards 0
2594
Figure 35. Maximum Permitted Glass Dimensions - Pyroguard T EI30/18-1 and 18-2
Glass Height
(mm)
2358
Maximum Area 3.40m2
1118 1342
Glass Width (mm)
Towards 0
3046
Figure 36. Maximum Permitted Glass Dimensions - Pyroguard T EI30/18-1VI and 18-2VI
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 71 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI60/25-3 and 25-3VI within Aluprof MB-78 EI aluminium framing screen system for periods of 60 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within an Aluprof MB-78 EI aluminium framed screen as detailled diagrammatically below. Please consult the frame manufacturer for full specification of framing system. Glazing and frame details are as described in Efectis test report No’s. EFR-14-V-003557A
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 72 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI60/25-3 and 25-3VI within Aluprof MB-78 EI aluminium framing screen system for periods of 60 minutes integrity and insulation This Certificate of Approval relates to the sizes of Pyroguard T EI60/25-3 and 25-3VI shown in Figure 37 and 38 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions.
Glass Height
(mm)
2800
Maximum Area 4.40m2
1470 1573
Glass Width (mm)
Towards 0
2996
Figure 37. Maximum Permitted Glass Dimensions - Pyroguard T EI60/25-3
Glass Height
(mm)
2200
Maximum Area 3.09m2
1312 1404
Glass Width (mm)
Towards 0
2354
Figure 38. Maximum Permitted Glass Dimensions - Pyroguard T EI60/25-3VI
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 73 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI60/25-3VI within Aluprof MB-78 EI aluminium framed door systems for periods of 60 minutes integrity and insulation For this application the following conditions shall apply: The glass shall be glazed within an Aluprof MB-78 EI aluminium framed doorset system as detailed diagrammatically below. Please consult the frame manufacturer for full specification and approved scope of doorset system. Glazing and frame details are as described in Efectis test report No’s. EFR-15-V-000202
This certificate is the property of Exova (UK) Limited trading as Warrington Certification
Reg. Office: Exova (UK) Limited, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Co. Reg. No. SC070429
CERTIFICATE No CF 5204
PYROGUARD UK LTD
Page 74 of 74 Signed D/007
Issued: 24th February 2014
Revised: 7th
November 2017 Valid to: 23
rd February 2019
Pyroguard T EI60/25-3VI within Aluprof MB-78 EI aluminium framed door systems for periods of 60 minutes integrity and insulation This Certificate of Approval relates to the sizes of Pyroguard T EI60/25-3VI shown in Figure 39 below, when used in conjunction with the above system. The aspect ratio of the glass may be unlimited within these aperture dimensions. Glass
Height
(mm)
Maximum Area 2.64m2
1118
Glass Width (mm)
Towards 0
2358
Figure 39. Maximum Permitted Glass Dimensions - Pyroguard T EI60/25-3VI