S.J.CHO / EMC Group Manager B.S.Kim / Chief Manufacturer : KESECO CO.,LTD. Comment(s) IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 08-IST-0005 Basic Model(s) : ULTra U-801 Address : 8F, NanYoung Bldg., 284-49 SungSuDong2GA, SungDong-Gu, Address : 8F, NanYoung Bldg., 284-49 SungSuDong2GA, SungDong-Gu, Test Report File No. : 08-IST-0005 Date of Issue : September 10, 2008 Kind of Product : Power Saving Appliance Electromagnetic Compatibility Seoul, Korea (133-120) Seoul, Korea (133-120) 1 of 10TRANSCRIPT
IST Co., Ltd. EMC LABORATORY
TEST REPORT NO. : 08-IST-0005
1 of 10
EMC TEST REPORT Electromagnetic Compatibility
□Emission ■ Immunity
Test Report File No. : 08-IST-0005 Date of Issue : September 10, 2008
Basic Model(s) : ULTra U-801
Kind of Product : Power Saving Appliance
Applicant : KESECO CO.,LTD.
Address : 8F, NanYoung Bldg., 284-49 SungSuDong2GA, SungDong-Gu,
Seoul, Korea (133-120)
Manufacturer : KESECO CO.,LTD.
Address : 8F, NanYoung Bldg., 284-49 SungSuDong2GA, SungDong-Gu,
Seoul, Korea (133-120)
Test Result □ Positive ■ Negative
Reviewed By Approved By
S.J.CHO / EMC Group Manager B.S.Kim / Chief
Comment(s)
-The test regulations are in page 3. -This test report consists of 10 pages with appendix. -The test result only responds to the tested sample. This report shall not be reproduced except in full, without the allowance of the test laboratory.
IST Co., Ltd. EMC LABORATORY
TEST REPORT NO. : 08-IST-0005
2 of 10
TABLE OF CONTENTS
Table of contents 2
Test regulations 3
Information of test laboratory, EUT Installed System,
Product Information
4
Equipment Under Test and test setup 5
Summary 6
□ Test Conditions and Data - Emissions
◇ Conducted Emissions 0.15 MHz - 30 MHz Not applicable
Test Conditions / Data and Plots
◇ Radiated Emissions 30 MHz - 1 GHz Not applicable
Test Conditions / Data and Plots
□ Test Conditions and Data – Generic
◇ Voltage Fluctuations Not applicable
Test Conditions / Data and Plots 14-16
■ Test Conditions and Data - Immunity
◇ Electro-Static Discharge Not applicable
Test Conditions / Data and Plots
◇ Radiated Susceptibility Not applicable
Test Conditions / Data and Plots
◇ Electrical Fast Transient (Burst) Not applicable
Test Conditions / Data and Plots
◆ Surge Transient Applicable
Test Conditions / Data and Plots 7-8
◇ Conducted Susceptibility Not applicable
Test Conditions / Data and Plots
◇ Voltage Dips, interruptions Not applicable
Test Conditions / Data and Plots
Appendix A. The EUT Photos 9
B. The Test Setup Photos 10
IST Co., Ltd. EMC LABORATORY
TEST REPORT NO. : 08-IST-0005
3 of 10
TEST REGULATIONS
The tests were performed according to 2004/108/EC directive and following
regulations :
□ Emissions
◇ EN55022:1998 +A1:2000 ,+A2:2003
■ Immunity
◆ EN55024:1998 +A1:2001, +A2:2003
◇ EN 61000-4-2:1995 +A1:1998, +A2:2001
◇ EN 61000-4-3:2006
◇ EN 61000-4-4:2004
◆ EN 61000-4-5:1995 +A1:2001
◇ EN 61000-4-6:1996 +A1:2001
◇ EN 61000-4-8:2003 +A1:2001
◇ EN 61000-4-11:2004
□ Generic
◇ EN61000-3-2:2006
◇ EN61000-3-3:1995 +A1:2001, +A2:2005
Note :
- ◆ means the test is applicable,
- ◇ is not applicable.
IST Co., Ltd. EMC LABORATORY
TEST REPORT NO. : 08-IST-0005
4 of 10
INFORMATION OF TEST LABORATORY
IST EMC LABORATORY
400-19, Singal-dong, Giheung-gu, Yongin-si, Gyeonggi-do, 446-599, Korea
TEL : +82 31 326 6700 FAX : +82 31 326 6799
Measurement Uncertainty
The measurement uncertainty was evaluated for all test items listed in
this report. Also it, “ The evaluation and treatment of uncertainty “,
is described in IST Quality Manual according to ISO17025 Guide. The data
and results described in this report are true and include evaluated
uncertainty. It may cause some deviation of uncertainty by change component
or process of the test for similar products.
PRODUCT INFORMATION Input Power 220 Vac, 60 Hz
-EMC suppression device is not used during the test.
-Find information in user manual.
IST Co., Ltd. EMC LABORATORY
TEST REPORT NO. : 08-IST-0005
5 of 10
Equipment Under Test
EUT Type :
Table-Top. Floor-Standing.
Table-Top and Floor-Standing(Combination).
Operation – mode of the E.U.T. :
The equipment under test was operated during the measurement under following conditions :
Standby Mode
Operational Condition : Normal operation mode.
Configuration of the equipment under test :
Following peripheral devices and interface cables were connected during the measurement :
Equipment Type Brand Serial No.
Connecting Interface Cables :
IST Co., Ltd. EMC LABORATORY
TEST REPORT NO. : 08-IST-0005
6 of 10
SUMMARY
Emissions □ Conducted Emissions (From 0.15 MHz To 30 MHz)
The requirements are ○ MET ○ Not MET
Minimum limit margin
Maximum limit exceeding
Remarks : Limits are kept with more than 3dB margin
□ Radiated Emissions (From 30 MHz To 1GHz)
The requirements are ○ MET ○ Not MET
Minimum limit margin
Maximum limit exceeding
Remarks : Limits are kept with more than 3dB margin
Generic Test □ Harmonic current
The requirements are ○ MET ○ Not MET
□ Voltage Fluctuations
The requirements are ○ MET ○ Not MET
Immunity
□ Electrostatic Discharge ○ MET ○ Not MET
□ Radiated Electromagnetic Fields ○ MET ○ Not MET
□ Electrical Fast Transient(Burst) ○ MET ○ Not MET
■ Surge Transient ○ MET ● Not MET
□ Conducted Susceptibility ○ MET ○ Not MET
□ Power Frequency Magnetic ○ MET ○ Not MET
□ Voltage Dips, interruption ○ MET ○ Not MET
Test date
Begin of test date: September 10, 2008
End of test date: September 10, 2008
Note : -■ means the test is applicable, □ is not applicable.
Prepared By
S.J.OH / EMC Engineer
IST Co., Ltd. EMC LABORATORY
TEST REPORT NO. : 08-IST-0005
7 of 10
TEST CONDITIONS AND DATA
Surge Transient
[Applicable]
◆ Test Equipment Used
The test equipment used is calibrated in regular for every year. Model Name Description Manufacture Calibration Date Serial No.
PSURGE 4.1 Surge Generator Haefely May 21, 2007 082876-05
◆ Environmental Conditions
Temperature 25 ℃
Humidity 47 %
Atmosphere pressure 1016 mbar
◆ Test Program Normal operation mode.
◆ Test Area EMS Test Room
◆ Test Date September 10, 2008
Note :
IST Co., Ltd. EMC LABORATORY
TEST REPORT NO. : 08-IST-0005
8 of 10
Surge Transient
[Applicable]
◆ Test Specification
Pulse amplitude
– Power line :
■ 1.0 kV : Line to line
■ 3.0 kV : Line to line■ 2.0 kV : Line to line
Pulse amplitude
– Data line :
□ 0.5 kV
□ 2.0 kV □ 1.0 kV
Source impedance : ■ 18 µF : Line to line
□ 40 Ω + 0.1 µF ■ 10 Ω + 9 µF: Line to ground
□ 40 Ω + 0.5 µF
Number of surges : □ 3 surges/angle ■ 5 surges/polarity
Angle ■ 0° ■ 90°
■ 180° ■ 270°
Repetition rate : □ 10 sec. ■ 60 sec.
Polarity : ■ Positive ■ Negative
Location of Coupling:
name of lines: Power cable length : 2.5 m
type of lines □ – shielded ■ - unshielded
status of lines: □ – passive ■ - active
kind of transmission: ■ - analog □ - digital
◆ Result :
□ No degradation of function Met Criterion A
■ Distortion of function Met Criterion B – incandescent lamp
■ Error of function Met Criterion C – fluorescent lamp
□ Loss of function Unrecoverable Failure -
Note : 1 kV – A fluorescent and incandescent lamp wear flickering. : Pass
2 kV - A incandescent lamp was flickering and ballast of fluorescent
was broken. : incandescent lamp – Pass, fluorescent lamp - Fail
3 kV - A incandescent lamp was flickering. : incandescent lamp – Pass
IST Co., Ltd. EMC LABORATORY
TEST REPORT NO. : 08-IST-0005
9 of 10
Appendix A. The EUT Photos
EUT View
EUT Set-up
IST Co., Ltd. EMC LABORATORY
TEST REPORT NO. : 08-IST-0005
10 of 10
Appendix B. Test Setup Photos
Surge Transient(Fluorescent)
Surge Transient(Incandescent)