Centrale termice/sobe_peleti/lemn
http://localhost/var/www/apps/conversion/tmp/scratch_6/P_P_Inglese.pptx -
8/13/2019 Centrale Termice RED Ro2012
2/107
_ Continut curs teoretic_sobe peleti RED tipuri: aer_multiaer_hydro._gama cazanelor pe peleti si lemn._specificatii tehnice si modul de alegere a unui produs pentru client._dimensionarea si diagramele unui sistem de instalatii._demonstratii practice - cum lucreaza a soba pe peleti RED?_demonstratii practice - cum lucreaza un cazan pelet/lemn?
_ Curs practic_programarea si functionarea avansata:
Ecostop, automatizare avansata prin minimalizarea puterii (prin termostat).gestionarea unui rezervor de stocare (puffer) extern.posibilitati de comunicare multiple, cu sisteme electronice suplimentareexistente.
acceptarea de sisteme aditionale, cum ar fi sisteme solare termice.sisteme externe de stocare, peleti, proiectate sa fie gestionate electronic.
_colaborarea si cu alte sisteme de incalzire, deja existente, din casa._prin experienta capatata, la aparatele pe peleti, s-au realizat centrale cuautocuratare.
A se vedea echipamentele noi, practic existente din 2012 (ex.: Logika).
_diagrame si dimensionari la sistemele standard._exemple si demonstratii de asamblari/dezasamblari la componentele primare.
_RED_centrale termice_programare
-
8/13/2019 Centrale Termice RED Ro2012
3/107
_ sobe
_RED_Gama: sobe si centrale
_ hydro
_ aer
_ multiaer
_ cazane
_ solare termice
_ alimentate cu peleti
_ alimentate cu lemn
_ accesorii _ rezervoare stocare
_ gestiune electronica
-
8/13/2019 Centrale Termice RED Ro2012
4/107
_RED_Gama de sobe
_ aer
margheritagardeniadalia
_ multiaer
primula orchidea
primula orchidea edera
-
8/13/2019 Centrale Termice RED Ro2012
5/107
_RED_Gama de sobe
_ hydro
margheritagardenia primula orchidea
21 kW
_ aer_ hydro_S
_ aer_ hydro/hydro_S
23 kW
_ simple_ hydro
11,6 kW
lotus
-
8/13/2019 Centrale Termice RED Ro2012
6/107
_RED_Gama de cazane_ peleti _Compact
compact 18 compact 24 compact 35
24 kW 35 kW
_ hydro_ hydro_S
_hydro- pompa de mare eficienta
_hydro- pompa _S de mare eficienta
18 kW
-
8/13/2019 Centrale Termice RED Ro2012
7/107
_RED_Gama de cazane_ peleti
pratika 28-33 variomatic 33
logika 25-35 logika 25-35 refill
-
8/13/2019 Centrale Termice RED Ro2012
8/107
_RED_Gama de cazane
_ lemn
Tecnika 28-35
-
8/13/2019 Centrale Termice RED Ro2012
9/107
_RED_Gama de accesorii
_Boilere stocatoare
puffer
tank-in-tankcylinder
puffer
pipe-in-tankDHW storagetank
-
8/13/2019 Centrale Termice RED Ro2012
10/107
_RED_Gama de accesorii
_panou solar
_accesorii
solar control
unit
200 litre
pellet tank
400 litre
pellet tank
condensation-
proof valves
timed
thermostat
-
8/13/2019 Centrale Termice RED Ro2012
11/107
_ sobe
_RED_cazane_sobe_gama
_ aer
-
8/13/2019 Centrale Termice RED Ro2012
12/107
_dalia_air
-
8/13/2019 Centrale Termice RED Ro2012
13/107
_gardenia_air
-
8/13/2019 Centrale Termice RED Ro2012
14/107
_margherita_air
-
8/13/2019 Centrale Termice RED Ro2012
15/107
_primula_air
-
8/13/2019 Centrale Termice RED Ro2012
16/107
_orchidea_air
-
8/13/2019 Centrale Termice RED Ro2012
17/107
_ sobe
_RED_cazane_sobe_game
_ multiaer
-
8/13/2019 Centrale Termice RED Ro2012
18/107
_primula_multiair
-
8/13/2019 Centrale Termice RED Ro2012
19/107
_orchidea_multiair
-
8/13/2019 Centrale Termice RED Ro2012
20/107
_edera_multiair
-
8/13/2019 Centrale Termice RED Ro2012
21/107
_ sobe
_RED_cazane_sobe_game
_ hydro
-
8/13/2019 Centrale Termice RED Ro2012
22/107
_gardenia_hydro
-
8/13/2019 Centrale Termice RED Ro2012
23/107
_margherita_hydro
-
8/13/2019 Centrale Termice RED Ro2012
24/107
_primula_hydro
-
8/13/2019 Centrale Termice RED Ro2012
25/107
_orchidea_hydro
-
8/13/2019 Centrale Termice RED Ro2012
26/107
_lotus_hydro
-
8/13/2019 Centrale Termice RED Ro2012
27/107
_RED_cazane_game
_centrale termice _ pe peleti_ pe lemn
t 18 i 24
-
8/13/2019 Centrale Termice RED Ro2012
28/107
_compact 18 si 24
combined with a storage tank ACS 110 lt_4 Hydraulic kits matched to the boiler :
Kit with the circulation pump only .Kit with the circulation pump and 30 kW DHW group .Kit with the high efficiency circulation pump only.Kit with the high efficiency circulation pump only and 30 kW DHW group
_ summer / winter function_ operation via power line communication
t 35
-
8/13/2019 Centrale Termice RED Ro2012
29/107
_compact 35
_combined with a storage tank ACS 110 lt_4 Hydraulic kits matched to the boiler :
Kit with the circulation pump only .Kit with the circulation pump and 30 kW DHW group .Kit with the high efficiency circulation pump only.Kit with the high efficiency circulation pump only and 30 kW DHW group
_ summer / winter function_ operation via power line communication
t
-
8/13/2019 Centrale Termice RED Ro2012
30/107
_compact
t
-
8/13/2019 Centrale Termice RED Ro2012
31/107
_compact
l ik 25 i 35
-
8/13/2019 Centrale Termice RED Ro2012
32/107
_logika 25 si 35
_lambda probe to control the combustion varying the primary and secondary air independently.
_ can be matched with the EASY CLEAN cleaning system (optional) for the automatic cleaning of the
turbolators and the expulsion and compaction of the ash in the convenient front trolley.
_ ACS hydraulic kit
_pellet tank included
_ operation via power line communication
l ik 25 i 35 l
-
8/13/2019 Centrale Termice RED Ro2012
33/107
_logika 25 si 35 cu reumplere
_lambda probe to control the combustion varying the primary and secondary air independently.
_ can be matched with the EASY CLEAN cleaning system (optional) for the automatic cleaning of theturbolators and the expulsion and compaction of the ash in the convenient front trolley.
_ ACS hydraulic kit
_ small pellet tank matched with a Pneumatic filling system from an external tank (big bag, etc.)
_ operation via power line communication
l ik
-
8/13/2019 Centrale Termice RED Ro2012
34/107
_logika
l ik
-
8/13/2019 Centrale Termice RED Ro2012
35/107
_logika
pratika 28 33
-
8/13/2019 Centrale Termice RED Ro2012
36/107
_pratika 28_33
_pellet loader auger included
_100 kg pellet tank included
_90% efficiency_also designed to burn dried olive or cherrystones
_pressurised combustion chamber
_pump not included
_expansion vessel not included
pratika
-
8/13/2019 Centrale Termice RED Ro2012
37/107
_pratika
pratika
-
8/13/2019 Centrale Termice RED Ro2012
38/107
_pratika
variomatic 33
-
8/13/2019 Centrale Termice RED Ro2012
39/107
_variomatic 33
_easy clean system for monthly cleaning
_130 kg pellet tank included
_93% efficiency_equipped with 2 fans
_vacuum combustion chamber
_pump not included
_expansion vessel not included
variomatic 33
-
8/13/2019 Centrale Termice RED Ro2012
40/107
_variomatic 33
variomatic 33
-
8/13/2019 Centrale Termice RED Ro2012
41/107
_variomatic 33
tecnika 28 35
-
8/13/2019 Centrale Termice RED Ro2012
42/107
_tecnika 28_35
_Pyrolysis inverted flame stove
_Automatic flame modulation system
_Loading chamber capacity 20 kg 24 kg
_85% efficiency
_Vacuum combustion chamber
_Pump NOT included
_Expansion vessel NOT included
tecnika
-
8/13/2019 Centrale Termice RED Ro2012
43/107
_tecnika
tecnika
-
8/13/2019 Centrale Termice RED Ro2012
44/107
_tecnika
-
8/13/2019 Centrale Termice RED Ro2012
45/107
_RED_cazane_sobe_game
_ panouri solare_ accesorii_ stocatoare
_ altele
accesorii (DHW) stocatoare acm
-
8/13/2019 Centrale Termice RED Ro2012
46/107
_accesorii_(DHW) stocatoare acm
_can be teamed with all boilers withDHW production
_optimal capacity 110 l
_easy to install
_lighter weight, 30 kg
_compact size
accesorii cilindrice
-
8/13/2019 Centrale Termice RED Ro2012
47/107
_accesorii_cilindrice
_the easiest system to exploit solar energy
_optimised heat exchange
_double coil
_DVGW approved double glazing
_thick polyurethane insulation
accesorii cilindrice
-
8/13/2019 Centrale Termice RED Ro2012
48/107
_accesorii_cilindrice
accesorii cilindrice
-
8/13/2019 Centrale Termice RED Ro2012
49/107
_accesorii_cilindrice
accesorii tank-in-tank pufere
-
8/13/2019 Centrale Termice RED Ro2012
50/107
_accesorii_ tank-in-tank _pufere
_to integrate heating with solar energy
_high capacity internal DHW cylinder
_DVGW approved double glazing
_thick polyurethane insulation
accesorii tank-in-tank pufere
-
8/13/2019 Centrale Termice RED Ro2012
51/107
_accesorii_ tank-in-tank _pufere
accesorii tank-in-tank pufere
-
8/13/2019 Centrale Termice RED Ro2012
52/107
_accesorii_ tank-in-tank _pufere
accesorii pipe-in-tank pufere
-
8/13/2019 Centrale Termice RED Ro2012
53/107
_accesorii_ pipe in tank _pufere
_to integrate heating with solar energy
_for intensive and continuous use of DHW
_DVGW approved double glazing
_thick polyurethane insulation
accesorii pipe-in-tank pufere
-
8/13/2019 Centrale Termice RED Ro2012
54/107
_accesorii_ pipe in tank _pufere
accesorii pipe-in-tank pufere
-
8/13/2019 Centrale Termice RED Ro2012
55/107
_accesorii_ pipe in tank _pufere
panou solar
-
8/13/2019 Centrale Termice RED Ro2012
56/107
_panou solar
accesorii unitati control
-
8/13/2019 Centrale Termice RED Ro2012
57/107
41
40 default diagrams
2 modular outputs
1 relay output
5 programmable inputs
_accesorii_unitati control
accesorii unitati de control
-
8/13/2019 Centrale Termice RED Ro2012
58/107
In the control unit,
choose the typeof solar SYSTEM
Simple diagram (System 1):suitable for solar DHW
integration
_accesorii_unitati de control
accesorii unitati de control
-
8/13/2019 Centrale Termice RED Ro2012
59/107
complex system (system 5):
suitable for solar heatingintegration
in the control unit,
choose the typeof solar system
_accesorii_unitati de control
acc
esorii unitati de control
-
8/13/2019 Centrale Termice RED Ro2012
60/107
additional functions
_DHW circulation_Post-heating (boiler)_solid fuel boiler_rapid loading_quantity of heat_thermostat_differential thermostat_range_reduced stagnation_holiday/cooling function
_antifreeze_anti-Legionellosis_data logger (on sd board)_alarm output
_accesorii_unitati de control
accesorii sisteme anti-condens
-
8/13/2019 Centrale Termice RED Ro2012
61/107
_it is a thermostatic valve fitted with a pump that mixes thewater and circulates it around the system, avoidingcondensation.
_it guarantees the temperature on the boiler return
_it allows auto-circulation of the fluid
_accesorii_sisteme anti condens
accesorii sisteme anti-condens
-
8/13/2019 Centrale Termice RED Ro2012
62/107
_accesorii_sisteme anti condens
accesorii cronotermostate
-
8/13/2019 Centrale Termice RED Ro2012
63/107
_accesorii_cronotermostate
RED sobe mod operare
-
8/13/2019 Centrale Termice RED Ro2012
64/107
_RED_sobe_mod operare
_diagrama explodata a aplicatiilor cu peleti
_operatii principale si utilizare_ aer
_multiaer_hydro
sectiunea la
-
8/13/2019 Centrale Termice RED Ro2012
65/107
_circuitul de fum
_circuitul de control
_circuitul de peleti
_sectiunea laechipament pe peletiO aplicatie hydro poate fiimpartita in 6 circuiteprincipale
_circuitul de apa
_cazan
circuitul de fum
-
8/13/2019 Centrale Termice RED Ro2012
66/107
1
2
3
4
5
6
7
_circuitul de fum
1. combustion chamber
2. exhaust smoke passagechamber
3. smoke extractor fan
4. combustion air inlet pipe
5. exhaust smoke outlet pipe
6. pellet igniter
7. glass cleaning andsecondary air inlet
circuitul de control siguranta
-
8/13/2019 Centrale Termice RED Ro2012
67/107
2
3
4
5
1
6
_circuitul de control-siguranta
1. mother board
2. tank temperature sensor
3. control panel4. smoke temperature sensor
5. pressure switch
6. ACTIVE SYSTEM sensor
circuitul de alimentare peleti
-
8/13/2019 Centrale Termice RED Ro2012
68/107
1
2
34
5
_circuitul de alimentare peleti
1. pellet storage tank
2. geared motor
3. auger or worm screw
4. pellet chute
5. brazier
sistemul hidraulic
-
8/13/2019 Centrale Termice RED Ro2012
69/107
_sistemul hidraulic
1. Expansion vessel2. Expansion vessel flexible hose3-4. Cut-off cock5-6. Cold water return pipes7-8. Hot water flow pipes
9.-11. Circulation pump pipe unions10. Circulation pump (water pump)12. 3 bar relief valve13. Pressure gauge (optional)14. Flow pipe from boiler15. Relief pipe
16. System pipe unions
cazanul
-
8/13/2019 Centrale Termice RED Ro2012
70/107
_cazanul
internal boiler with capacity of between
17 and 20 litres equipped with turbolators to increasethe heat exchange with water
consisting of:_pipe bundle_inspection panel_turbolators_flow_return
made entirely out of steel andtested at a maximum pressure of 4
bar
_kitul de productie a.c.m.
-
8/13/2019 Centrale Termice RED Ro2012
71/107
_the COMPACT 24 comes with all the devices necessary foroperation.
It is therefore sufficient to make the connections to the existingplumbing system_hydro stoves can also be equipped with a kit for the instantproduction of domestic hot water
consisting of:30 kW plate heat exchangerthree-way diverter valveflow switch
Dt = 40 Cflow rate of 10 l/min
for heavy duty usage, it is always advisable to install a storagetank.
utilizare RED sobe cu aer
-
8/13/2019 Centrale Termice RED Ro2012
72/107
red stoves give customers the opportunity to choose:
_utilizare_RED_sobe cu aer
_the room temperature_the flame power_the hot air fan power
utilizare RED sobe cu aer
-
8/13/2019 Centrale Termice RED Ro2012
73/107
Use knobAto set the hotair fan speed
Use knob Bto select theroom temperature.
Use knob Cto set theflame power.
There are 5differentpower settings
The customer should select the
desired room temperature (B) andthe flame power (C)
The flame will remain on the settingmade by the customer until the
temperature in the room reachesthat set; once the desiredtemperature is reached, the stovewill automatically switch tominimumpower (flame setting 1).
_utilizare_RED_sobe cu aer
utilizare RED sobe multiaer
-
8/13/2019 Centrale Termice RED Ro2012
74/107
In RED MULTIAIR appliances, the fan power controlis the same as described earlier, but with the addedpossibility of selecting the quantity of air intended forthe rear, i.e. for the 100 mm ducting, and the
quantity intended for the front, i.e. through the frontgrille.
The choice is made using a lever situated at the top
of the stove, which has default positions.
_utilizare_RED_sobe multiaer
utilizare RED sobe cu aer
-
8/13/2019 Centrale Termice RED Ro2012
75/107
25C
_calibrarea arderii
This allows the user to adjust the stove according tothe type of fuel purchased.
Having seen the existing differences betweendifferent pellet qualities, this adjustment if vital forthe correct functioning of the appliance, to avoidconsuming too many pellets and to keep theappliance intact.
_utilizare_RED_sobe cu aer
utilizare RED sobe cu aer
-
8/13/2019 Centrale Termice RED Ro2012
76/107
Depending on the flame characteristics (shape, colour and"character") and on the user's experience (brazier too full or tooempty), an adjustment can be made to the fuel chute into thebrazier.This adjustment can be made using button Ewhich allows you to
increase the quantity of pellets by + 10%or +20%or to decreaseit by -10%or -20%.The stove is factory set with a calibration of0% (no change), in other words for an average quality certifiedpellet.
_calibrarea arderii
_utilizare_RED_sobe cu aer
utilizare RED sobe hydro
-
8/13/2019 Centrale Termice RED Ro2012
77/107
red stoves give customers the opportunity to choose:
_utilizare_RED_sobe hydro
_the room temperature_temperature of water in the boiler
utilizare RED sobe hydro
-
8/13/2019 Centrale Termice RED Ro2012
78/107
_the flame power cannot be adjusted
_only the desired room temperature can be adjusted and,depending on the difference between the temperaturerequested and the temperature set, the stove selects thecorrect operating power._the temperature of the water in the boiler can be set.
GO LSThe stove must reach_the water temperature set
_the desired room temperatureIF THESE TWO TEMPERATURES ARE NOT REACHED, THE
STOVE WILL NOT DECREASE ITS OPERATING POWER
_utilizare_RED_sobe hydro
utilizare RED sobe hydro
-
8/13/2019 Centrale Termice RED Ro2012
79/107
straight after start-up, the stove needs to (insequence):
_heat the water to the circulation pump start-up temperature
_mix all the water in the system.
_heat all the water in the system to the temperature set (for
instance: 65
C)
_utilizare_RED_sobe hydro
utilizare RED sobe hydro
-
8/13/2019 Centrale Termice RED Ro2012
80/107
the circulation pump
until all the water in the system is not above 50 C(2 C), the circulation pump will perform a seriesof start-ups and shutdowns.
the water in the boiler reaches 50 C (2 C), thecirculation pump begins the mix the water and coldwater returns to the boiler.the water in the boiler therefore cools down and the
circulation pump stops. When all the water in theboiler and in the system has a temperature of morethan 50C (2 C), the circulation pump operatescontinuously
_utilizare_RED_sobe hydro
utilizare RED sobe hydro
-
8/13/2019 Centrale Termice RED Ro2012
81/107
Always ensure the power yielded to the water by theappliance does NOT correspond to the total power. If thepower absorbed by the system is higher, the stove will nevermanage to reach the delivery temperature.
possible faults in the systemif the water in the system does not reach the desiredtemperature, you need to check:
_ the system's absorption in kW or calories.
_ the system insulation_ the speed of water circulation in the system_ the temperature set in the boiler_ the distribution of water in the system.
_utilizare_RED_sobe hydro
RED cazane operare
-
8/13/2019 Centrale Termice RED Ro2012
82/107
_RED_cazane_operare
_operating principle
_fundamental values
_safety devices
_usage
RED cazane operare
-
8/13/2019 Centrale Termice RED Ro2012
83/107
_RED_cazane_operare
Cold water Hot water
Smoke
Air
(a)
CO, CO2, NOx
Pellet
Wood
_general concepts
RED cazane operare
-
8/13/2019 Centrale Termice RED Ro2012
84/107
_RED_cazane_operare
Temperature(C)
Time (s)
Temperature(C)
Time (s)
Fig.1 Off/On: flamestep-by-stepregulation
Fig.2Continuousmodulation: withcontinuous flame
regulation.
Temperature value
set
Temperature
value set
_general concepts
RED cazane operare
-
8/13/2019 Centrale Termice RED Ro2012
85/107
_RED_cazane_operare
_nominal heat output, this is the maximum power that the boiler is capable of yielding tothe system; it is measured in kW (or kcal/h, 1 kW = 860 kcal).
_heat output range, this is the range of heat outputs the boiler can provide
_boiler class,i.e. classification according to UNI EN 303-5
_efficiency, this is the boiler efficiency
expressed as a percentage
_maximum operating pressure, themaximum pressure the boiler can tolerate.Size the safety valve appropriately.
_Volume of water, which affects thethermal inertia of the system
_Load running time
_DHW flow rate, expressed in l/min witha DT=20 C or 30 C
_general concepts
RED cazane operare
-
8/13/2019 Centrale Termice RED Ro2012
86/107
_RED_cazane_operare
Smoke pressure switch or thermostatIf for any reason the flue duct is partially or totally obstructed, therebycompromising its functioning, the boiler is shut down by the smoke thermostat or bythe smoke pressure switch.
Water flow switch or pressure switch
When the quantity of water in the boiler heating circuit is insufficient, the boiler is
shut down by the water pressure switch.Safety valve
When the pressure of the water in the boiler exceeds the value permitted due to amalfunctioning, the safety valve is triggered and drains the water outside.
Limit thermostat and safety thermostat
When the temperature of the water exceeds the limit (normally a value of 85 C),
the limit thermostat is triggered and momentarily switches off the boiler. If for anyreason the limit thermostat is not triggered, the boiler is shut down by a secondsafety thermostat which is triggered at 100 C.
Flame detection device
When the burner flame does not ignite due to a malfunctioning, the flame detectiondevice shuts down the boiler (not pyrolysis).
_general concepts
RED cazane operare
-
8/13/2019 Centrale Termice RED Ro2012
87/107
_RED_cazane_operare_panel adjustments
_operation demo
_RED sobe_centrale termice
-
8/13/2019 Centrale Termice RED Ro2012
88/107
_choosing the product
_red cazane/sobe
-
8/13/2019 Centrale Termice RED Ro2012
89/107
_choosing the product
_the size of the room to be heated_the insulation of the room_the shape of the room_the customer's heat requirements_primary or secondary heating?_primary or secondary home?_the existing heating system and its heat output_heat technician's calculation_what's the position of the flue pipe
to choose the right product for your customer, keepthe following factors in mind:
_red cazane/sobe
-
8/13/2019 Centrale Termice RED Ro2012
90/107
_choosing the product
For instance:_the size of the room the customer wants to heat: 120 m2x 2.7 ceilingheight.
_the insulation of the room:average_the shape of the room: open-space living area and 3 bedrooms + 2
bathrooms_the customer's heat requirements: 20-22C_primary or secondary heating?: primary without DHW production, which
the existing gas boiler in the home will cover_primary or secondary home? primary_the existing heating system and its heat output: 24 kW gas boiler_heat technician's calculation: system's absorption 16.2 kW_what's the position of the flue pipe: living area adjacent to the boilerroom
You need to have the answers to all these questions before making areasoned and correct proposal to the customer.
_red cazane/sobe
-
8/13/2019 Centrale Termice RED Ro2012
91/107
_choosing the product
If a heat technician's calculation is available, this is without a doubtmore reliable because it takes into account the system's heat dispersionbut it will do no harm to run a check with our own parameters:
_since we know we have to heat approximately 351 m3in an average
insulated home, we can calculate the minimum kcal or kW required:351 m3x 35 kcal = 12,285 kcal = 14.28 kW
according to our calculation, our product should have at least 14.28 kWbut it is always a good idea to oversize the choice by about 15-
20%to avoid the appliance operating on maximum at all times =14.28 + (15% of 14.28kW) = 16.42 kW
_our choice therefore lands on an appliance that has a heat output ofat least 16.42 kW yielded to the water
_red cazane/sobe
-
8/13/2019 Centrale Termice RED Ro2012
92/107
_choosing the product
_The heat technician's calculation confirms that our calculation comesvery close to the actual energy requirements of the system.
_Caution: we mean the plumbing system's requirements, not
those of the home. This means that if the appliance isundersized, it will never be able to run regularly and satisfy thedelivery temperature requirements.
_When choosing the product, do not underestimate the operating hours
and the need to manage timed programmes or automatic start-ups andshutdowns depending on the temperature.
_hydro_sobe_cazane
-
8/13/2019 Centrale Termice RED Ro2012
93/107
_system diagrams
_hydroexclusive system with external DHW production
-
8/13/2019 Centrale Termice RED Ro2012
94/107
_exclusive system with external DHW production
_hydro/smixed exclusive system
-
8/13/2019 Centrale Termice RED Ro2012
95/107
_mixed exclusive system
_hydro/smixed exclusive system with by-pass
-
8/13/2019 Centrale Termice RED Ro2012
96/107
_mixed exclusive system with by pass
_hydro/sDHW storage tank
-
8/13/2019 Centrale Termice RED Ro2012
97/107
_DHW storage tank_mixed exclusive system
_hydro/ssystem shared with wall-hung boiler
-
8/13/2019 Centrale Termice RED Ro2012
98/107
_system shared with wall hung boiler
_hydro/sDHW storage tank
-
8/13/2019 Centrale Termice RED Ro2012
99/107
_ g_system shared with boiler
_hydropipe in tank storage tank with DHW production
-
8/13/2019 Centrale Termice RED Ro2012
100/107
_p p g p_solar with control unit
_hydro/sDHW production cylinder
-
8/13/2019 Centrale Termice RED Ro2012
101/107
_ p y_solar with control unit
_hydro_DHW production cylinder
-
8/13/2019 Centrale Termice RED Ro2012
102/107
_ p y_solar with control unit
_hydro_tank in tank storage tank
-
8/13/2019 Centrale Termice RED Ro2012
103/107
_ g_solar with control unit
_hydro_tank in tank storage tank
-
8/13/2019 Centrale Termice RED Ro2012
104/107
_ g_solar with control unit
_hydro_pipe in tank storage tank
-
8/13/2019 Centrale Termice RED Ro2012
105/107
p p g_solar with control unit
_hydro_pipe in tank storage tank
-
8/13/2019 Centrale Termice RED Ro2012
106/107
p p g_solar with control unit
_hydro_pipe in tank storage tank
-
8/13/2019 Centrale Termice RED Ro2012
107/107