Page 1: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

INTERCOM SYSTEM

TOA EXES-5000 INTERCOM SYSTEM

EXES-5000 CPU-55

Central Processing Unit

CPU-55INSTALLATION HAND BOOK

TOA ELECTRIC CO., LTD.KOBE, JAPAN

133-21-005-5

Page 2: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

CONTENTS

• INTRODUCTION TO THE OPERATION MANUAL FOR EXES - 5000 . . . . . . . . . . . . . . .

• FUNCTIONS WHICH REQUIRE ADDITIONAL UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . .

— PART 1. Operating of CPU Unit and No. 200 Programming —

1. Precautions for Installation of CPU-55 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

4

5

6

8

10

11

12

Page

< Function Group A >

6-1 Executive Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-2 Continuous Calling T o n e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-3 Stations Allowed Access to All C a l l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-4 Stations Allowed Access to C o n f e r e n c e . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-5 Stations Allowed Access to One-shot Make O u t p u t . . . . . . . . . . . . . . . . . . .

6-6 Stations Allowed Access to Make/Break O u t p u t . . . . . . . . . . . . . . . . . . . . .

6-7 Stations Allowed Access to 8 Selectable/Decimal O u t p u t . . . . . . . . . . . . . .

6-8 Stations Allowed Access to 4 Decimal Digits Output . . . . . . . . . . . . . . . . .

FUNCTION CODE

50 . . . . . . . . 12

51 . . . . . . . . 13

52 . . . . . . . . 14

53 . . . . . . . . 15

56 . . . . . . . . 16

57 . . . . . . . . 17

58 . . . . . . . . 18

59 . . . . . . . . 19

< Function Group B >

6-9 Secretary T r a n s f e r . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

6-10 Master/Sub Relationship . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

< Function Group C >

6-11 Paging Priority and/or Paging Response. . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

6-12 Group Blocking: Establishment of each Group . . . . . . . . . . . . . . . . . . . . . 71

< Function Group D >

6-13 Combination Paging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

6-14 Group Blocking: Allowing Calls among Groups . . . . . . . . . . . . . . . . . . . . . 81

6-15 Group Blocking: Allowing Access to P a g i n g . . . . . . . . . . . . . . . . . . . . . . . . 82

< Function Group E >

6-16 Programmable Station N u m b e r i n g . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

. . . . . . . . 20

. . . . . . . . 21

. . . . . . . . 22

. . . . . . . . 23

. . . . . . . . 24

. . . . . . . . 25

. . . . . . . . 26

. . . . . . . . 27

2. Initial CPU-55 set up

3. Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4. CPU-55 DIP-Switches for Function Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5. Function Code Table for Station No. 200 Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6. Station No. 200 Programming for Each Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

- 1 -

Page 3: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

7. Programming Lis t for Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• Function Table for Stations (1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• Function Table for Stations (2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• Function Table for Stations ( 3 ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• Function Table for Stations (4). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• Paging Priority and Paging Response Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• Combination Paging Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• 3 Examples of Group Blocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

— Part 2. Function Selection for Data Transmitting and Receiving Units —

8. Setting of Channel Select Switch of Transmitting Unit (DT-E11) and Word

Select Switch of Receiving Unit (DR-B61) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9. DIP Switch Table for Data Transmitting and Receiving Units . . . . . . . . . . . . . . . . . . . . . . . . . . .

10. System Diagram of Data Transmitting and Receiving U n i t s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11. Explanation of Data Transmitting Unit Output Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12. Explanation of Data Receiving Unit Output C h a n n e l s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page

28

28

29

30

31

32

32

33

34

35

36

38

39

39

40

41

42

43

44

45

46

47

48

12-1 CH-0

12-2 CH-1

12-3 CH-2

12-4 CH-3

12-5 CH-4

12-6 CH-5

12-7 CH-6

12-8 CH-7

12-9 CH-8

12-10 CH-9

IN-OUT Annunciation (500 c o n t a c t s ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Make/Break Output (512 c o n t a c t s ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

One-shot Make Output (500 c o n t a c t s ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 Decimal Digits Output (9 U n i t s ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Decimal Output (9 Units)

8-Selectable Make Outputs (9 Units)

Pager Control Output (240 Contacts)

Decimal Output (99 Units) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8-Selectable "Make" Outputs (64 U n i t s ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Calling Party Indication (Numerical) ( 1 ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Calling Party Indication (Numerical) ( 2 ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Calling Party Indication (Lamp) ( 1 ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Calling Party Indication (Lamp) (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

- 2 -

Page 4: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

• INTRODUCTION TO THE OPERATION MANUAL FOR EXES - 5000

This manual forms part of the Installation Manual forTOA INTERCOM SYSTEM EXES-5000.You may add the CPU-55 to your TOA INTERCOMSYSTEM EXES-5000, according to your specific needs,to obtain various other functions. Correct operation ofthese additional functions are not available by onlyconnection of the additional equipments/devices.Provision of such additional functions requires thefollowing:(1) connection of the additional equipment, as required,(2) selection of functions which satisfy your needs and

setting up these functions in the respective equipment.For (1) Connections of Equipment, etc., refer to In-stallation Handbook of Model EX-510/520 EXCHANGEor "Manual for Installation of Data Transmitting andReceiving Units", etc.

INSTALLATION HAND BOOK OF EXES - 5000

EXES - 5000EX - 510/520INSTALLATIONHAND BOOKOF EXCHANGE

Or"EXES - 5000INSTALLATIONHAND BOOK

EXES - 5000CPU - 55INSTALLATIONHAND BOOK133-21-005-5

This Hand Book

DATATRANSMITTINGAND RECEIVINGUNIT

Or"DT-E11 OPERATION MANUAL" 133-05-094-1

"DR-B61 OPERATION MANUAL" 133-05-095-0

SYSTEMS OF EXES - 5000

System using CPU-55

System with Display and Control functions using

CPU-55

System using CPU-52A

REQUIRED INSTALLATION HAND BOOK

EX-510/520EXCHANGE

CPU-55 CPU-52A DATA TRANS-MITTING ANDRECEIVINGUNIT

This "Installation Handbook of CPU-55" deals principallywith (2) selection of functions and setting up of respectiveequipment.There are certain minimum installation requirements to bemet even though you may not need many additional func-tions or additional equipment, it is still necessary to read"2. Initial CPU-55 Set Up (Page 6.)". When you may useonly some of the additional functions or equipments, it isnot necessary to read instructions on unrequired functions.Make sure, however, that careful study of the necessaryparts of this booklet should be done before proceedingfurther.Note 1; Refer to Installation handbook of CPU-52A",

when installing a standard call and Paging system,using CPU-52A.

Note 2; Refer to respective manuals when other types ofCPU and connection equipment/devices are used.

- 3 -

Page 5: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

Function

Talk-Back frompaging speaker

Conference

External PA Paging

Station Paging(including prioritypaging).

All call plus 15 in-dividual pagingzones

Combination Paging

Emergency All CallPaging

Additional EquipmentRequired

Talk-Back Unit

Conference Unit

Paging Interface Unit

Paging Interface Unit

Paging Interface Unit

Output Control Unit

Paging Interface Unit

Paging Interface Unit

Unit ModelNos.

TKU-11

CLU-52

PIU-52/52A

PIU-52/52A

PIU-52/52A(2 pcs)

OCU-52A

PIU-52A

PIU-52/52A

Remarks

Optional amplifier (10W max.) may be re-quired depending on application

External PA Equipment is required.

1. Wiring of "Station Paging AssignmentPlug" located at the back of the frame ofthe Exchange.

2. Cutting of LMU jumper wire to split sta-tion paging system. (Refer to ServiceManual for LMU-52/52A, PIU-52/52A).

1. PIU No. 1 is for All Call plus 7 pagingzones (No. 0 ~ 7).

2. PIU No. 2 is for 8 paging zones. (No. 8 ~15) Adjusting jumper wire on PIU isrequired).

3. Wiring of "Station Paging AssignmentPlug" is required.

(Connection of all call signal on 2 PIUs).1. For EX-510, (64 stations)

Connect "P0" and "256".2. For EX-520, (128 stations)

Connect "PO" and "312".

OCU-52 must be modified.(Add M9, M17 and TTL IC 7475 2 pcs.)

PIU-52 can not be used.

Operate by the privacy switch on stationNo. 247, or by a circuit to control "OFF/ON" status of loop current when voice signalsare externally generated.

• FUNCTIONS WHICH REQUIRE ADDITIONAL UNITS

Those functions of the CPU-55 which require either the addition of specific units or processing in existing units are asmentioned below. Before installation and adjustment of equipment, make sure to check your system.(For Data Transmitting and Receiving units, refer to Part 2. "Function Selection for Data Transmitting and Receivingunits" Page 34.)

Position of PIU Units for All-Call Paging and 15 Indivisual Zone Paging

CPU - 55

OCU - 52A

HCU - 52

SGD - 52A

CLU - 52

DLU - 52

LMU - 52A

PIU-52/52A No.1(Zone 0-7 with All-Call Paging)PIU-52/52A No.2(Zone 8-15 without All-Call Paging)

AC POWER INDICATOR LAMP

BATTERY POWER INDICATOR LAMP

BUZZER STOP SWITCH

DS-510A

- 4 -

Page 6: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

PART 1. OPERATING OF CPU UNIT AND NO. 200 PROGRAMMING1. PRECAUTIONS FOR INSTALLATION OF CPU-55

Please read following instructions carefully to ensure proper operation of the CPU-55.

1. Be careful about damage by static electricity as theCPU-55 incorporates CMOS IC's. Do not touch com-ponents and connectors.

2. Turn off the AC power switch when you take out orinsert the CPU-55 unit, or any other unit.

3. Always insert the CPU-55 unit into the "CPU" slot.Otherwise, there is a danger that the unit will bedamaged.

4. Make sure mini-jumper for battery back-up is alwaysplaced in ON position each time it is used.

5. Incorrect setting of function select switches may leadto incorrect performance.

6. Even if you do not need programming functions, besure to carry out initial programming and registrationat station No. 200 when you install the new unit.Otherwise, some other functions may not workproperly.

7. The Ni-Cd battery GB50-3FA1 is capable of saving im-portant memory registration data even at times ofpower failure and we suggest you replace i t at leastevery 4 years.

8. When shipping the CPU-55 unit independently, placethe mini-jumper for battery back-up in "OFF" position.Then cover CPU back with cardboard, wrap connectorsection in aluminium foil and put it in a conductivebag.

t functions.

, PAGING AMP. REMOTE

g normally.

N

.

H for #200 Programing

n only at time of initial program-d registration of functions. In this

0 is "programming station" but be-

n when switch is placed in "OFF"

: Do not remove!

y back-up (JP1)1 (3.6V 50mAh)

- 5 -

FUNCTION SELECT SWITCHES

SW-E (1 ~ 6)

SW-D (1 ~ 6)

SW-C (1 ~ 6)

SW-B (1 ~ 6)

SW-A (1 ~ 5) :

These switches selec

LINK SELECTION

"RUN" INDICATION

Shows the CPU is workin

"SELF RESTART" INDICATIO

Lights if the CPU self-restarts

PROGRAM SWITC

Set this "ON" positioing of the exchange ancase, station No. 20

comes a normal statioposition.

FIXED MINI-JUMPER (JP2) Note

MINI-JUMPER for batterNi-Cd BATTERY GB50-3FA

Page 7: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

2. INITIAL CPU-55 SET UP

Make sure that you have turned off the AC power switch.

Connect the exchange, terminal boards and stations.

YESAre Data Transmitting and Receiving Units connected ?

Remove CPU-55 from the exchange.

NO

Set mini-jumper (JP1) for battery from OFF to ON position.

Set function selection switches (SW-A ~ SW-E) forrequired functions.

Insert the CPU-55 into the exchange.

Switch on the exchange.

Look at indication of LINE ADDRESS of HCU (14 LEDs) and SIGNALCODE indication (4 LEDs)

All LED lamps are out

SIGNAL CODE indication

F 4 2 1

Memory is normal

Some errors in memory

Lighted lamps of LINE ADDRESSLEDs indicate erroneous MEMORYICs. See Section 3 (Page 8).

Place program switch on front panel of the CPU "ON".

to be continued

1. Connect Data Transmitting Unit(DT-E11) and Data ReceivingUnit (DR-B61).

2. Set channel select switches(CHANNEL SELECT) ofDT-E11.

3. Set word select switches (WORDSELECT) of DR-B61.

Put all 4 "link select" switches of the HCU unit upward.(Link No.15)

- 6 -

Page 8: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

Dial operation from station No. 200.

— Initial programming of the exchange —

Dial the Following:

1.

2.

3.

4.

5.

6.

7.

Dial tone will be heard (Station No.200 becomes a programming station)

; Confirmation tone will be heard.(Clears function group A)

; Confirmation tone will be heard.(Clears function group B)

; Confirmation tone will be heard.(Clears function group C)

; Confirmation tone will be heard.(Clears function group D)

; Confirmation tone will be heard.(Clears function group E)

; Confirmation tone will be heard.(Clears personal numbers and single digit dial numbers)

10 times

10 times

10 times

10 times

10 times

10 times

Program necessary functions

Remark: If there is any error in CMOS memory, you hear calling tone instead of confirmation tone.

Place program switch on front panel of the CPU in "OFF" position.

Dial operation from station No. 200.

(Station No. 200 becomes a normal station.)

- 7 -

Page 9: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

3. TROUBLE SHOOTING

3-1 Check of ROM & NMOS-RAM - No calls on the system.

1. Put the 4 "LINK SELECT" switches of the HCU upward (Link No. 15 SELECT) and switch on the AC

power of the exchange.

2. If there is no error, the indication lamps will not light.

3. In the event of a memory error, the lamps may light as shown in the example of Fig. 1.

4. The error indications will remain on until you use Link No. 15 for communications.

Error ROM • RAM Chip No.Example

No.1 and No.2 out of 5 pcsROMs (2716) have "read"error.

No.0 and No.1 out of 4 setsof N-MOS RAMs (2114) have"read" error.(One set of RAMs consist of2 ICs)

Indicate memory error.

LINK SELECT Switches setto select No. 15

Fig. 1

3-2 Check of CMOS-RAM (Programmed data memory)

At the time of initial programming and registration using station No. 200,

1. You hear calling tone instead of confirmation tone, if there is CMOS memory error when registering single

digit number or personal number.

2. Indication on front panel of the CPU.

"RUN" LED indicator

When the system is working normally, LED is "on".

Check its condition when the system fails to work normally.

"SELF RESTART" LED indicator

This does not light when the system is working normally. Even if the high noise from the outside of the exchange

causes the CPU to work abnormally, the CPU "self-restarts" and the system keeps on working normally. Once

the CPU "self-restarts", the LED indicator is on, but it does not affect system. If you again cycle the AC power

source, the LED indicator is turned off.

- 8 -

Page 10: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

3-3 Dial receiving test

If you place all "LINK SELECT" switches (1 ~ 4) of SW-A on the CPU-55 in "OFF" position, conversation is

impossible but the dial code from each station is indicated on the LED's of the PIU as dialed. Use this to find

the cause of any fault of receiving dial information.

DIP switches(SW-A of the CPU)

Fig. 2

Fig. 3 Dial code indication

3-4 The order of link usage.

After power is on, links are used in numerical order for each communication.

Remember this to help you when problems are found with specific links.

Remarks:

1. Be sure to avoid mistake at time of DIP switch installation and No. 200 Programming since such mistake may

lead to trouble later.

2. Be sure to make "No. 200 Programming" after "Function Registration List" (attached to this manual) is filledout. Keep the finished "Function Registration List" (Initial Checking Sheet for the System 133-21-024-4)

as a part of complete drawings for each installation.

DIGITS DIALED

PIU LED No.

(PTT)

PR

ES

S

RE

LE

AS

E

PR

IVA

CY

PR

IVA

CY

ON ON

- 9 -

Page 11: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

4. CPU-55 DIP SWITCH FUNCTION SELECTION

S W - A

S W - B

S W - C

S W - D

S W - E

Functions

Link Selection ; Link No. 0 ~ 3

Link Selection ; Link No. 4 ~ 7

Link Selection ; Link No. 8 ~ 11

Link Selection ; Link No. 12 ~ 15

Time Interval Adjustment before Paging

Pre-announce tone

On

Activate

1 Sec.

Off

Not Activate

None

Conference

Call Transfer

Priority & Executive Priority

Paging, Paging During Normal Calls

Calling tone Duration Selection

System Size Selection

Activate

0.7 Sec.

EX-520

Not Activate

1.3 Sec.

EX-510

Paging Pre-announce Tone Duration Selection

Emergency All-Call

Paging Priority

Combination Paging

15 Individual Paging Zones

2-Digit Dialing (#20 ~ #99)

1 Sec.

Activate

15 Zones

Activate

2 Sec.

Not Activate

7 Zones

Not Activate

Stations Allowed Access to All Call

Stations Allowed Access to Conference

Stations Allowed Access to General Purpose Control

Group Blocking

Programmable Station Numbering(#20 ~ #99 or #200 ~ #999)

General Purpose Control

Activate Not Activate

Off

Off

Off

Pager (240 Contacts Output)

Off

Continuous Calling Tone

Activate

Activate

Not Activate

Not Activate

OFF ON1

2

3

4

5

OFF ON1

2

3

4

5

6

OFF ON

1

2

3

4

5

6

OFF ON1

2

3

4

5

6

OFF ON1

2

3

4

5

6

- 10 -

Page 12: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

Funct

ion

Gro

up

A B C D E

Funct

ion

Exe

cutiv

eP

rio

rity

Co

ntin

uo

us

Ca

llin

gT

on

e

Sta

tion A

llow

ed

Acc

ess

to A

ll C

all

Sta

tio

ns

Allo

we

dA

cces

s to

Co

nfe

ren

ceS

tatio

ns

Allo

we

dA

cce

ss t

o O

ne

Sh

ot

f Ma

ke O

utp

ut

Sta

tio

ns

Allo

we

dA

cces

s to

Ma

ke/

Bre

ak

Outp

ut

Sta

tio

ns

Allo

we

dA

cces

s to

8 S

elec

-ta

ble

/De

cim

al O

ut-

put

Sta

tio

ns

Allo

we

dA

cces

s to

4D

eci

ma

l Dig

itsO

utp

ut

Se

cre

tary

Tra

nsf

er

Mast

er/

Sub

Pag

ing

Res

ponc

e,P

agin

g P

rio

rity

Gro

up B

lockin

g:

Est

ab

lish

me

nt o

fe

ach

gro

up

Co

mb

ina

tio

nP

agin

g

Gro

up B

lock

ing

:A

llow

ing

Ca

llsA

mo

ng G

rou

ps

Gro

up B

lockin

g:

Allo

win

g A

cce

ssto

Pag

ing

Zon

es

Pro

gra

ma

ble

Sta

tio

n N

um

be

rin

g

Funct

ion

Cod

e

50

51 52

53

56

57

58 59 60 61 70

71

80

81

82 90

1st P

ara

mete

r

Sta

tion N

o.

(200 -

32

7)

(20

~ 9

9)

Sta

tio

n N

o.

(200 ~

327)

(20

-9

9)

Sta

tion

N

o.

(200 ~

327)

(20 - 9

9)

Sta

tion N

o.

(200

~ 3

27)

(20 - 9

9)

Sta

tion N

o.

(200 -

327)

(20 - 9

9)

Sta

tio

n N

o.

(200 -

327)

(20 - 9

9)

Sta

tion N

o.

(200 -

327)

(20 - 9

9)

Sta

tio

n N

o.

(200 ~

32

7)

(20 - 9

9)

Exe

cutiv

eS

tatio

n N

o.

Sub S

tatio

n N

o.

Zo

ne N

o.

(01

~ 1

5)

Gro

up N

o.

(1 -8

)

Co

mb

ina

tio

nZ

on

e N

o.

(90

~ 9

9)

Ca

llin

g G

rou

pN

o.

(1 -

8)

Pag

ing

zone

No.

of p

aged

gro

up

(00-1

5,9

0-9

9)

Hard

wired S

tatio

nN

o.

(200 -

32

7)

(20 - 9

9)

2nd P

ara

mete

r

ON

/OF

F (

1/0

)

ON

/OF

F (

1/0

)

ON

/OF

F (

1/0

)

ON

/OF

F

(1/0

)

ON

/OF

F (

1/0

)

ON

/OF

F (

1/0

)

ON

/OF

F (

1/0

)

ON

/OF

F (

1/0

)

Se

cre

tary

Sta

tio

n N

o.

Mat

er S

tatio

nN

o.

Th

e F

irst

Sta

tion N

o.

of

the Z

on

e

Th

e F

irst

Sta

tio

n N

o.

of

the G

rou

p

3rd

Para

mete

r

Th

e L

ast

Sta

tion N

o.

of

the

zon

eT

he L

ast

Sta

tion N

o.

of

the G

rou

p

Zo

ne

No.

(s)

(0

1 -1

5)

(Plu

ral)

Calle

d G

rou

pN

o.

(s)

(1

-8)

(Plu

ral)

Pag

ing

Gro

up

No.

(s)

(1

-8)

(Plu

ral)

Pro

gra

mm

ed

Sta

tion N

o.

(200 -

999)

(20 - 9

9)

5.

Funct

ion C

ode T

able

for

Sta

tion N

o. 2

00 P

rogr

amm

ing

OP

ER

AT

ING

FO

R P

RO

GR

AM

MIN

G

- 11

-

Page 13: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6. STATION NO. 200 PROGRAMMING FOR EACH FUNCTION6-1 EXECUTIVE PRIORITY (FUNCTION CODE 50)

EXECUTIVE PRIORITY

Step 1

Touch

Function Code

New Registration ? NO

YES

Executive Station No. ON

Touch

Executive Station No. ON

Touch

Confirmation tone

NO New Registration finished ?

YES

NORelease ?YES

Executive Station No. OFF

Touch

Executive Station No. OFF

Touch

Confirmation tone

NO Release finished ?YES

Return

NOTES

1. To register all stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

2. To release all registered stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

3. Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

4. Station No. should be 2 digits in length when 2 Digit

Dialing function is employed.

5. CPU DIP switch B-3 must be "ON" to employ this

function.

- 12 -

Page 14: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-2 CONTINUOUS CALLING TONE (FUNCTION CODE 51)

CONTINUOUS CALLING TONE

Step 1

Touch

Function Code

NONew Registration ?YES

Continuously Called Station No. ON

Touch

Continuously Called Station No. ON

Touch

Confirmation tone

NO New Registration finished ?

YESNORelease ?

YES

Continuously Called Station No. OFF

Touch

Continuously Called Station No. OFF

Touch

Confirmation tone

NO Release finished ?

YES

Return

NOTES

1. To register all stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

2. To release all registered stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

3. Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

4. Station No. should be 2 digits in length, when 2 Digit

Dialing function is employed.

5. CPU DIP switch E-6 must be "ON" to employ this

function.

- 13 -

Page 15: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-3 STATIONS ALLOWED ACCESS TO ALL CALL (FUNCTION CODE 52)

STATIONS ALLOWED ACCESS TO ALL CALL

Step 1

Touch

Function Code

NONew Registration ?

YES

Allowed Station No. ON

Touch

Allowed Station No. ON

Touch

Confirmation tone

NO New Registration finished ?

YES

NORelease ?YES

Allowed Station No. OFF

Touch

Allowed Station No. OFF

Touch

Confirmation tone

NO Release finished ?YES

Return

NOTES

1. To register all stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

2. To release all registered stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

3. Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

4. Station No. should be 2 digits in length, when 2 Digit

Dialing function is employed.

5. Programming is necessary only if CPU DIP switch D-1 is

"ON".

- 14 -

Page 16: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-4 STATIONS ALLOWED ACCESS TO CONFERENCE (FUNCTION CODE 53)

STATIONS ALLOWED ACCESS TO CONFERENCE

Step 1

Touch

Function Code

New Registration ? NO

YES

Allowed Station No. ON

Touch

Allowed Station No. ON

Touch

Confirmation tone

NO New Registration finished ?

YES

Release ? NO

YES

Allowed Station No. OFF

Touch

Allowed Station No. OFF

Touch

Confirmation tone

NO Release finished ?

YES

Return

NOTES

1. To register all stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

2. To release all registered stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

3. Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

4. Station No. should be 2 digits in length when 2 Digit

Dialing function is employed.

5. Programming is necessary only if CPU DIP switch

D-2 is "ON". Switch B-1 must be "ON" to employ

this function.

- 15 -

Page 17: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-5 STATIONS ALLOWED ACCESS TO ONE SHOT MAKE OUTPUT (FUNCTION CODE 56)

STATION ALLOWED ACCESS TO ONE SHOT MAKE OUTPUT

Step 1

Touch

Function Code

New Registration ? NO

YES

Allowed Station No. ON

Touch

Allowed Station No. ON

Touch

Confirmation tone

NO New Registration finished ?YES

Release ? NO

YES

Allowed Station No. OFF

Touch

Allowed Station No. OFF

Touch

Confirmation tone

NO Release finished ?YES

Return

NOTES

1. To register all stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

2. To release all registered stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

3. Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

4. Station No. should be 2 digits in length when 2 Digit

Dialing function is employed.

5. Programming is necessary only if CPU DIP switch

D-3 is "ON". Switch D-6 must be "ON" to employ

this function.

- 16 -

Page 18: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-6 STATIONS ALLOWED ACCESS TO MAKE/BREAK OUTPUT (FUNCTION CODE 57)

STATIONS ALLOWED ACCESS TO MAKE/BREAK OUTPUT

Step 1

Touch

Function Code

New Registration ? NO

YES

Allowed Station No. ON

Touch

Allowed Station No. ON

Touch

Confirmation tone

NO New Registration finished ?

YES

NORelease ?YES

Allowed Station No. OFF

Touch

Allowed Station No. OFF

Touch

Confirmation tone

NO Release finished ?

YES

Return

NOTES

1. To register all stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

2. To release all registered stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

3. Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

4. Station No. should be 2 digits in length when 2 Digit

Dialing function is employed.

5. Programming is necessary only if CPU DIP switch

D-3 is "ON". Switch D-6 must be "ON" to employ

this function.

- 17 -

Page 19: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-7 STATIONS ALLOWED ACCESS TO 8 SELECTABLE (OR DECIMAL) OUTPUT (FUNCTION CODE 58)

STATIONS ALLOWED ACCESS TO 8 SELECTABLE (OR DECIMAL) OUTPUT

Step 1

Touch

Function Code

NONew Registration ?YES

Allowed Station No. ON

Touch

Allowed Station No. ON

Touch

Confirmation tone

NO New Registration finished ?

YES

NORelease ?YES

Allowed Station No. OFF

Touch

Allowed Station No. OFF

Touch

Confirmation tone

NO Release finished ?

YES

Return

NOTES

1. To register all stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

2. To release all registered stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

3. Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

4. Station No. should be 2 digits in length when 2 Digit

Dialing function is employed.

5. Programming is necessary only if CPU DIP switch

D-3 is "ON". Switch D-6 must be "ON" to employ

this function.

- 18 -

Page 20: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-8 STATIONS ALLOWED ACCESS TO 4 DECIMAL DIGITS OUTPUT (FUNCTION CODE 59)

STATIONS ALLOWED ACCESS TO 4 DECIMAL DIGITS OUTPUT

Step 1

Touch

Function Code

New Registration ? NO

YES

Allowed Station No. ON

Touch

Allowed Station No. ON

Touch

Confirmation tone

NO New Registration finished ?

YES

Release ? NO

YES

Allowed Station No. OFF

Touch

Allowed Station No. OFF

Touch

Confirmation tone

NO Release finished ?

YES

Return

NOTES

1. To register all stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

2. To release all registered stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

3. Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

4. Station No. should be 2 digits in length when 2 Digit

Dialing function is employed.

5. Programming is necessary only if CPU DIP switch

D-3 is "ON". Switch D-6 must be "ON" to employ

this function.

- 19 -

Page 21: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-9 SECRETARY TRANSFER (FUNCTION CODE 60)

SECRETARY TRANSFER

Step 1

Touch

Function Code

New Registration ? NO

YES

Executive Station No. Secretary Station No.

Touch

Executive Station No. Secretary Station No.

Touch

Confirmation tone

NO New Registration finished ?

YES

Release ? NO

YES

Executive Station No. Executive Station No.

Touch

Executive Station No. Executive Station No.

Touch

Confirmation tone

NO Release finished ?

YES

Return

NOTES

1. To release all registered stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

2) Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

3) Station No. should be 2 digits in length when 2 Digit

Dialing function is employed.

- 20 -

Page 22: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-10 MASTER/SUB RELATIONSHIP (FUNCTION CODE 61)

MASTER/SUB RELATIONSHIP

Step 1

Touch

Function Code

New Registration ? NO

YES

Sub Station No. Master Station No.

Touch

Sub Station No. Master Station No.

Touch

Confirmation tone

NO New Registration finished ?

YES

Release ? NO

YES

Sub Station No. Sub Station No.

Touch

Sub Station No. Sub Station No.

Touch

Confirmation tone

NO Release finished ?

YES

Return

NOTES

1. To release all registered stations at one time,

Touch

10 times

(Confirmation tone will be heard.)

2. Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

3. Station No. should be 2 digits in length when 2 Digit

Dialing function is employed.

- 21 -

Page 23: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-11 PAGING RESPONSE AND PAGING PRIORITY (FUNCTION CODE 70)

PAGING RESPONSE

PAGING PRIORITY

Step 1

Touch

Function Code

Paging Zone No.

(01 ~ 15)

1st Station No.

of the Zone

Last Station No.

of the Zone

Touch

Paging Zone No.

(01 ~ 15)

1st Station No.

of the Zone

Last Station No.

of the Zone

Touch

Confirmation tone

NO New Registration finished ?

YES

Return

NOTES

1. To release all registered Zones at one time,

Touch

10 times

(Confirmation tone will be heard.)

2. Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

3. Station No. should be 2 digits in length when 2 Digit

Dialing function is employed.

4. Switch B-4 must be "ON" to employ this function.

- 22 -

Page 24: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-12 GROUP BLOCKING ; ESTABLISHING GROUPS (FUNCTION CODE 71)

GROUP BLOCKING 1

ESTABLISHMENT OF EACH GROUP

Step 1

Touch

Function Code

Group No.(1 ~ 8)

1st Station No.of the Group

Last Station No.of the Group

Touch

Group No.(1 ~ 8)

1st Station No.of the Group

Last Station No.of the Group

Touch

Confirmation tone

NO New Registration finished ?YES

Return

NOTES

1. To release all registered Zones at one time,

Touch

10 times

(Confirmation tone will be heard.)

2. Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

3. Station No. should be 2 digits in length when 2 Digit

Dialing function is employed.

4. CPU DIP switch D-4 must be "ON" to employ this

function.

- 23 -

Page 25: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-13 COMBINATION PAGING (FUNCTION CODE 80)

COMBINATION PAGING

Step 1

Touch

Function Code

New Registration ? NO

YES

Combination PagingZone No. (90 ~ 99)

Paging Zone No. (s)(01 ~ 15) (01 ~ 15)

Touch

Combination PagingZone No. (90 ~ 99)

Paging Zone No. (s)(01 ~ 15) (01 ~ 15)

Touch

Confirmation tone

NO New Registration finished ?

YES

Release ? NO

YES

Combination Paging Zone No. (90 — 99)

Touch

Combination Paging Zone No. (90 ~ 99)

Touch

Confirmation tone

NO Release finished ?YES

Return

NOTES

1. To release all registered Combination Paging Zones atone time,

Touch

10 times

(Confirmation tone will be heard.)

2. Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

3. CPU DIP switch B-4 and C-4 must be "ON" to employthis function.

- 24 -

Page 26: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-14 GROUP BLOCKING ; ALLOWING CALLS AMONG GROUPS (FUNCTION CODE 81)

GROUP BLOCKING 2

ALLOWING CALLS AMONG GROUPS

Step 1

Touch

Function Code

New Registration ? NO

YES

Calling GroupNo. (1 ~ 8)

Called GroupNo. (s) (max. 7)

Touch

Calling GroupNo. (1 ~ 8)

Called GroupNo. (s) (max. 7)

Touch

Confirmation tone

NO New Registration finished ?

YES

Release NO

YES

Calling Group No. (1 ~ 8)

Touch

Calling Group No. (1 ~ 8)

Touch

Confirmation tone

NO Release finished ?

YES

Return

NOTES

1. To release all registered Calling Groups at one time,

Touch

10 times

(Confirmation tone will be heard.)

2. Re-start at Step 1 when mis-dialing occurs

(All other registrations remain valid.)

3. Do not register a Group to call itself.

4. CPU DIP switch D-4 must be "ON" to employ this

function.

- 25 -

Page 27: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-15 GROUP BLOCKING ; ALLOWING GROUP ACCESS TO PAGING ZONES (FUNCTION CODE 82)

GROUP BLOCKING 3

ALLOWING ACCESS TO PAGING ZONES

Step 1

Touch

Function Code

New Registration ? NO

YES

Paging Group No. (S)(1 ~ 8) (max. 8)

Touch

Touch

Paging Group No. (S)(1 ~ 8) (max. 8)

Confirmation tone

NO New Registration finished ?

YES

Release ? NO

YES

Touch

Touch

Confirmation tone

NO Release finished ?

YES

Return

NOTES

1. To release all registered Paging Zones at one time,

Touch

10 times

(Confirmation tone will be heard.)

2. Re-start at Step 1 when mis-dialing occurs

(All other registrations remain valid.)

3. CPU DIP switch D-4 must be "ON" to employ this

function.

Paging Zone

(00 ~ 15)

or

Combination Paging

Zone

(90 ~ 99)

- 26 -

Page 28: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

6-16 PROGRAMMABLE STATION NUMBERING (FUNCTION CODE 90)

PROGRAMMABLE STATION NUMBERING

Step 1

Touch

Function Code

New Registration ? NO

YES

Touch

Touch

1 2

1 2

Confirmation ton

NO New Registration finished ?

YES

Release ? NO

YES

1 1

1 1

Touch

Touch

Confirmation tone

NO Release finished ?

YES

Return

1 : Hardwired StationNumber

(200 ~ 327)( 20 ~ 99 )

2 : Programmed StationNumber

(200 ~ 999)( 20 ~ 99 )

NOTES

1. To release all registered Programmed Station No. at

one time,

Touch

10 times

(Confirmation tone will be heard.)

2. Re-start at Step 1 when mis-dialing occurs.

(All other registrations remain valid.)

3. Any one Programmed Station No. cannot be assigned

to more than one Hardwired Station.

4. CPU DIP switch D-5 must be "ON" to employ this

function.

- 27 -

Page 29: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

7. PROGRAMMING LIST FOR FUNCTIONS

Use these tables to keep a record of those functions assigned to each station.

Function Table for Stations (1)

* Register using Hardwired Station No.

Exe

cutiv

e P

rior

ity

Con

tinuo

us C

allin

g T

one

Sta

tions

Allo

we

d A

cces

sto

All

Cal

l

Sta

tions

Allo

we

d A

cces

sto

Con

fere

nce

Sta

tions

Allo

we

d A

cces

sto

One

Sho

t M

ake

Outp

ut

Sta

tions

Allo

we

d A

cces

sto

Mak

e/B

reak

Outp

ut

Sta

tions

Allo

wed

Acc

ess

to 1

/8S

elec

t (o

r D

ecim

al)

Out

put

Sta

tions

Allo

wed

Acc

ess

to 4

Dec

imal

Dig

its O

utp

ut

Sec

reta

ry

*S

tatio

n N

o.

Mas

ter

*S

tatio

n N

o.

Pag

ing

Zon

e N

o.

Gro

up N

o. f

or G

roup

Blo

ckin

g

Pro

gram

med

Sta

tion

No.

Function GroupF

unct

ion

Cod

e

Fun

ctio

n

Name

- 28 -

Page 30: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

Function Table for Stations (2)

* Register using Hardwired Station No.

A

Exe

cutiv

e P

riority

Con

tinuo

us C

allin

g T

one

Sta

tions

Allo

we

d A

cces

sto

All

Cal

l

Sta

tions

Allo

we

d A

cces

sto

C

onfe

renc

e

Sta

tions

Allo

wed

Acc

ess

to O

ne S

hot

Mak

e O

utp

ut

Sta

tions

Allo

wed

Acc

ess

to M

ake/

Bre

ak O

utp

ut

Sta

tions

Allo

we

d A

cces

s to

1/8

Sel

ect

(or

Dec

imal

) O

utp

ut

Sta

tions

Allo

we

d A

cces

s to

4D

ecim

al

Dig

its O

utp

ut

B

Sec

reta

ry

*S

tatio

n N

o.

Mas

ter

*S

tatio

n N

o.

C

Pag

ing

Zon

e N

o.

Gro

up N

o. f

or G

roup

Blo

ckin

g

E

Pro

gram

med

Sta

tion

No.

Function Group

Funct

ion

Cod

e

Funct

ion

Name

- 29 -

Page 31: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

Function Table for Stations (3)

* Register using Hardwired Station No.

A

Exe

cutiv

e P

rio

rity

Co

ntin

uo

us

Cal

ling

Ton

e

Sta

tions

Allo

we

d A

cces

sto

A

ll C

all.

Sta

tions

Allo

we

d A

cces

sto

Con

fere

nce

Sta

tions

Allo

we

d A

cces

sto

One

Sho

t M

ake

Outp

ut

Sta

tions

Allo

we

d A

cces

sto

Ma

ke/B

rea

k O

utp

ut

Sta

tions

Allo

we

d A

cces

s to

1/8

Sel

ect

(or

Dec

imal

) O

utp

ut

Sta

tions

Allo

we

d A

cces

s to

4D

ecim

al D

igits

Ou

tpu

t

B

Sec

reta

ry

*

Sta

tion

No.

Mas

ter

*

Sta

tion

No.

C

Pag

ing

Zon

e N

o.

Gro

up

No

. fo

r G

rou

p B

lock

ing

E

Pro

gram

med

Sta

tion

No.

Function Group

Funct

ion

Cod

e

Fu

nct

ion

Name

- 30 -

Page 32: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

Function Table for Stations (4)

* Register using Hardwired Station No.

Funct

ion

Cod

e

Fu

nct

ion

Name

Exe

cutiv

e P

rio

rity

Con

tinuo

us C

allin

g T

one

Sta

tions

Allo

we

d A

cces

sto

All

Cal

l

Sta

tions

Allo

wed

Acc

ess

to C

onfe

renc

e

Sta

tions

Allo

wed

Acc

ess

to O

ne S

hot

Mak

e O

utp

ut

Sta

tions

Allo

wed

Acc

ess

to M

ake/

Bre

ak O

utp

ut

Sta

tions

Allo

we

d A

cces

s to

1/8

Sel

ect

(or

Dec

imal

) O

utp

ut

Sta

tions

Allo

we

d A

cces

s to

4D

ecim

al D

igits

Ou

tpu

t

Sec

reta

ryS

tatio

n N

o.

*M

aste

rS

tatio

n N

o.

Pag

ing

Zon

e N

o.

Gro

up N

o. f

or G

roup

Blo

ckin

g

Pro

gram

med

Sta

tion

No.

- 31 -

*

Page 33: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

Paging Priority and/or Paging Response Table

Combination Paging Table

Station Paging Zone

Department No.1st Station No. Last Station No.

Selected Paging Zone

CombinationPaging Zone

Fun

ctio

n C

ode

70 For

Pag

ing

Pri

ority

For

Pag

ing

Res

pons

e

Dep

artm

ent

Fun

ctio

n C

ode

80

Department

- 32 -

Page 34: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

Tables for Group Blocking

No need to register.

Gro

up B

lock

ing

for

each

Gro

upG

roup

Blo

ckin

gam

ong

Gro

ups

Gro

up B

lock

ing

for

Pag

ing

Gro

ups

Group 1st Station No. Last Station No.No.

1

2

3

4

5

6

7

8

Calling

Group No.

Others

Paging Zone

Department

All Call

Paging Group No.Others

Indiv

idual P

agin

g Z

ones

Funct

ion

Cod

e 82

Com

bin

atio

n P

agin

g Z

ones

Called Group No.Others

1

2

3

4

5

6

7

8

No.

00

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

90

91

92

93

94

95

96

97

98

99

Fu

nct

ion

Cod

e 81

Fu

nct

ion

Cod

e 71

1 2 3 4 5 6 7 8

- 33 -

Page 35: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

PART 2. FUNCTION SELECTION FOR DATA TRANSMITTING ANDRECEIVING UNITS8. SETTING OF CHANNEL SELECT SWITCH OF TRANSMITTING UNIT (DT-E11) AND WORD

SELECT SWITCH OF RECEIVING UNIT (DR-B61)NOTE

1. Connect the DT-E11 and DR-B61 to Exchange cor-

rectly. (Refer to installation manuals of DT-E11 and

DR-B61.)

2. Set the function select switches (DIP SWITCH) on

CPU-55 correctly and be sure to enter initial pro-

gramming and function registration at programming

station No. 200.

3. Remove the front panel of Data Transmitting Unit

(DT-E11) and take out the printed circuit board. Then

set the channel select switches located on the printed

circuit board, according to the necessary functions

such as IN/OUT Annunciation, Calling Party Indication

etc, and replace in the Unit.

(Refer to 12, Explanation of Data Transmitting UnitOutput Channels, Page 39).

4. The DT-E11 sends out 512 bit data (16 bit x 32 words)

to control relays on Data Receiving Unit (DR-B61).

Therefore set the two word select switches on DR-B61,

according to necessary output mode. SW-1 is for

Relay No.1 to No.16 and SW-2 is for Relay No.17 to

No. 32. See Page 41 for details.(Refer to Explanation of Data Receiving Unit Output

Channels.)

ConnectingCable YR-802

ConnectingCableYR-803 To other DR-B61

Relay Number

To otherDT-E11

CHANNEL SELECTSwitch (SW-1)

To other RD-B61

WORD SELECTSwitch(SW-1, SW-2)

- 34 -

Page 36: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

< DIP SWITCH CHART OF DATA TRANSMITTING AND RECEIVING UNIT >

Exchange

Data TransmitterData Receiver Relay Output No.

Eac

h ch

anne

l outp

ut

of D

T-E

11 m

ay b

e co

nnec

ted

to D

R-B

61(s

) (a

s ab

ove

for

CH

.0)

Note: shows the Head of a Slide Switch

- 35 -

Page 37: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

10. System Diagram of Data Transmitting and Receiving Units

YR-802

YR-803

YR-803

YR-803

YR-803

YR-803

YR-803

YR-803

YR-803

YR-803

Exchange

YR-801

Stations

Data Transmitting Unit

Two wires

< Data Receiver(Equipment using DR-B61) >

In/Out AnnunciationDisplay Board

Prescription DisplayBoard, etc.

Prescription DisplayBoard, etc.

a. President,b. Department Chief,

c. Section Chief,d. Chief Clerk

Room Condition Indication,Destination Indication, etc.

a. Conference Room,b. Reception Room,

c. Outd. Waiting Room

Room Condition Indication,Destination Indication, etc.

Room Condition Indication,Destination Indication.

Calling Party DisplayBoard.Indication by decimaldigits.

Called Party withIndicatorNo. 200 ~ 215

Called Party withIndicatorNo. 216 ~ 231

Calling Party DisplayBoard.1 Station 1-lampIndication.

Called Party withIndicatorNo. 232 ~ 235

Called Party withIndicatorNo. 236 ~ 239

In/Out Annunciations(500 contacts)

Make-Break Output(512 contacts)

One-shot-Make Output(500 contacts)

(1) 4 Decimal Digits Output (9 Units)(2) Decimal Output (9 Units)(3) 8 Selectable Make Output (9 Units)(4) Pager Control (240 contacts)

Decimal Output (99 Units)

8 Selectable Make Output(64 Units)

Calling Party Indication.Numerical Type (1)

Calling Party Indication.Numerical Type (2)

Calling Party Indication.Lamp Type (1)

Calling Party Indication.Lamp Type (2)

EXES-5000EX-510/520 BOX-064

DT-E11CH.0

DT-E11CH. 1

DT-E11CH.2

DT-E11CH.3

DT-E11CH.6

DT-E11CH. 7

DT-E11CH.8

DT-E11CH.9

Power supplyDC 24V

or Room Condition Indication.Destination Indication.

or VTR, ITV interface

CallingParty

WaitingParty

No. ofWaiting Parties

DT-E11CH. 5

DT-E11CH.4

- 36 -

Page 38: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

YR-802

YR-803

YR-803

YR-803

Exchange

Data Transmitting Unit

Two wires

EXES-5000EX-510/520

DT-E11CH.6

Calling Party Indication.Numerical Type. (1)

< Calling Party Display Panel with DR-B61 >

Station numbers ofCalled Parties with Indicator

No.200

16 units

CallingParty

WaitingParty

Nos. ofWaiting Parties

No.201

No. 215

No. 216

CallingParty

WaitingParty

Nos. ofWaiting Parties

No. 217

16 units

No.231

No. 232

4 units

1-call = 1 -lampMaximum indications; 128 calls

No.233

No.234

No.235

No.236

4 units

1-call = 1-lamp,Maximum indications; 128 calls.

No.237

No.238

No.239

Calling Party Indication;Lamp Type. (2)1 -station = 1-lamp indication.

Power SupplyDC 24V

DT-E11CH.9

Calling Party Indication.Lamp Type. (1)1-station = 1-lamp indication.

DT-E11CH.8

Calling Party Indication.Numerical Type. (2)

DT-E11CH.7

- 37 -

Page 39: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

FUNCTIONS

IN/OUT Annunciation

Make/Break Output

One-shot Make Output

(1) 4 Decimal digits output

(9 unit blocks)

(2) Decimal Output

(9 unit blocks)

(3) 8 Selectable Make Output

(4) Pager Control Output

Decimal Output

(99 unit blocks)

8 Selectable make Output

Calling Party Indication

Numerical-type (1)

Calling Party Indication

Numerical-type (2)

Calling Party Indication

(One Station; One Lamp)

Calling Party Indication

(One Station; One Lamp)

DESCRIPTION

Personnel in and out registration can

be accomplished at any Master sta-

tion by using personal numbers Max.

500 IN/OUT annunciations may be

done.

512 Make/Break contacts can be

available at any Master station.

500 One-shot make contacts can be

available at any Master station.

Indicate by 7 segments LEDs.

10 Selectable Decimal Outputs are

available with 7 segments LEDs.

One contact out of 8 selectable make

output is obtained.

Make output (240 contacts) are

available for pager control.

10 Selectable Decimal Outputs are

available with 7 segments LEDs.

One contact out of 8 selectable make

output is obtained.

When a station with a Display Board

is called, calling party number is in-

dicated until the conversation is over

and also when the called station is

busy or in privacy.

Max. 128 Calling station numbers can

be indicated when designated called

station with Display Board is called.

Same as above except called station

number

APPLICATION

• IN/OUT Annunciation

• Door Remote

• IN/OUT Annunciation

• I TV camera select

• VTR control

• Prescription annunciation.

• Room condition indication.

• Destination indication

• Pager

• Room condition indication,

• Destination indication.

Same as above

• The number of called stations

are No. 200 ~ No. 215.

• The number of called stations

are No. 216 ~ No. 231.

• The number of called stations

are No. 232 ~ No. 235.

• The number of called stations

are No. 236 ~ No. 239.

11. EXPLANATION OF DATA TRANSMITTING UNIT OUTPUT CHANNELS

CHANNEL SELECT

CH. 0

CH. 1

CH. 2

CH. 3

CH. 4

CH. 5

CH. 6

CH. 7

CH. 8

CH. 9

- 38 -

Page 40: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

Each Relay Output showslast 3 digits (xxx) of Personal

Number

12. EXPLANATION OF DATA RECEIVING UNIT OUTPUT CHANNELS

12-1 Channel 0 (CH. 0) In/Out Annunciation(Dial Operation)Personal Number Registration

Personal Number Cancellation

Note: shows the Head of a Slide Switch

Data Receiver Relay Output No.

(Relay Make) XXX: 000 ~ 499 (500 contacts)

(Relay Break)Exchange

Data Transmitter

- 39 -

Page 41: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

12-2 Channel 1 (CH. 1) Make/Break Output

(Dial Operation)Exchange

Data Transmitter

(Relay Make) XXX: 000 ~ 511 (512 contacts)

(Relay Break)

Data Receiver Relay Output No.

Each Relay Output showsRelay Contact Number.

Note: shows the Head of a Slide Switch

- 40 -

Page 42: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

12-3 Channel 2 (CH. 2) One-Shot Make Output

(Dial Operation)

Exchange

Data TransmitterData Receiver

(Relay Make min. 1ms max. 2ms) XXX : 000 ~ 499 (500 contacts)

Relay Output No.

Each Relay Output showsRelay Contact Number.

Note: shows the Head of a Slide Switch

- 41 -

Page 43: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

12-4 Channel 3 (CH. 3) (1) 4 Decimal Digits Output(3) 8-Selectable Make Output

(2) Decimal Output(4) Pager Control Output

Exchange

Data Transmitter

(Example)(1) 4 Decimal Digits Output

Unit No. 6

Unit No. 7

Binary Output Negative Logic

(2) Decimal OutputUnit No. 8 Condition "9"

Binary NegativeLogic Output

(3) 8 Selectable Make OutputUnit No. 4 Condition "0"

Unit No. 6 Condition "7"

1: Relay Make0: Relay Break

(4) Pager Control OutputPager No. 127 is beingcalled.

Each Relay Output showsRelay Contact Number.

Relay Output No.Data Receiver

(1)

4 D

ecim

al D

igits

Ou

tpu

t[

9 U

nits

]

(2)

Dec

imal

Ou

tpu

t[

9 U

nits

]

(3)

8-S

elec

tabl

eM

ake

Outp

ut

[ 9

Units

]

(4)

Page

r C

ontr

ol O

utp

ut

[ 240

Co

nta

cts

]

Note: shows the Head of a Slide Switch

- 42 -

Page 44: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

12-5 Channel 4 (CH. 4) Decimal Output (99 Units)

(Dial Operation)

Exchange

Data Transmitter

(Example)

Unit No. 24 Condition "3"

Binary Negative Logic "3"

Data Receiver

XX : 01 ~ 99 Y : 0 ~ 9

Relay Output No.

Unit No. 48 Condition "0"

Binary Negative Logic "0"

1: Relay Make0: Relay Break

Note: shows the Head of a Slide Switch

- 43 -

Page 45: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

12-6 Channel 5 (CH. 5) 8-Selectable Make Output (64 Units)

(Dial Operation)

Exchange

(Example)

Unit No. 8 Condition "0"

Unit No. 10 Condition "7"

Data Receiver Relay Output No.

xx: 01 ~ 64 Y : 0 ~ 7

1: Relay Make0: Relay Break

Note: shows the Head of a Slide Switch

- 44 -

Page 46: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

12-7 Channel 6 (CH. 6) Calling Party Indication Numerical Type (1)

7 Segments Display of "Calling Station No. ", "Waiting Station No." and "Total Number ofWaiting Stations." Total Number of Station with Indications, 16 stations/ChannelExchange

Data TransmitterData Receiver Relay Output No.

(Example)

d.c.: Digit of Calling Station No.d.w.: Digit of Waiting Station No.t.n.w.: Total Number of Waiting

Station—logic: Binary negative logic1: Relay Make0: Relay Break

Note: shows the Head of a Slide Switch

CHANNEL SELECT Switch

Station No.with Indication

No.200

No.201

No.202

No.203

No.204

No.205

No.206

No.207

No.212

No.213

No.214

No.215

WORD SELECT Switch

No.208

No.209

No.210

No.211

Station No. 204Lamp "OFF" Condition

Station No. 206Lamp "ON" Condition

- 45 -

Page 47: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

12-8 Channel 7 (CH. 7) Calling Party Indication Numerical Type (2)

7 Segments Display of "Calling Station No.", "Waiting Station No." and "Total Number ofWaiting Station." Total Number of Station switch Indications, 16 stations/Channel

Data ReceiverRelay Output No.

Exchange

Data Transmitter

(Example)

d.c.: Digit of Calling Station No.d.w.: Digit of Waiting Station No.t.n.w.: Total Number of Waiting

Station—logic: Binary negative logic1: Relay Make0: Relay Break

Note: shows the Head of a Slide Switch

- 46 -

Page 48: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

12-9 Channel 8 (CH. 8) Calling Party Indication Lamp Type (1)

Each "Calling Station" or "Waiting Station" is shown by Each Lamp of Indication.

Total Number of Station with Indications : 4 Stations/Channel (8 Stations/2 Channels)Total Number of Calling Stations : Max. 128 Stations/Each Indication

Exchange

Data TransmitterData Receiver Relay Output No.

Each Relay Output shows"Calling Station No."

Note: shows the Head of a Slide Switch

- 47 -

Page 49: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

Each "Calling Station" or "Waiting Station" is shown byEach Lamp of Indication.Total Number of Station with Indications : 4 Stations/Channel (8 Stations/2 Channels)Total Number of Calling Stations : Max. 128 Stations/Each Indication

12-10 Channel 9 (CH. 9) Calling Party Indication Lamp Type (2)

Exchange

Data TransmitterData Receiver Relay Output No.

Each Relay Output shows"Calling Station No."

Note: shows the Head of a Slide Switch

- 48 -

Page 50: Central Processing Unit CPU-55 - toacanada.com · intercom system toa exes-5000 intercom system exes-5000 cpu-55 central processing unit cpu-55 installation hand book toa electricco.,

TOA ELECTRIC CO., LTD.

Printed in Japan