Page 1: Central Heating Management System

CentralHeating

Management System

SES Scottish Energy Saving

Page 2: Central Heating Management System

Unique The Central Heating Management System is a tried, tested and proven product

Considerable research, development, funding and time have been invested

The result is probably the most efficient and beneficial central heating enhancement product on the market

Independently tested and accredited at UKAS test facilities

Thousands of satisfied customers

Page 3: Central Heating Management System

How radiant

heat works

Radiant heat is a form of radiation

It penetrates air without loss of energy and heats objects individually The CHMS helps significantly increase the proportion of radiant heat emitted by a radiator

It increases your COMFORT FACTOR

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

Air temperature20OC / 70OF

Air temperature20OC / 70OF

You feel comfortable when radiant heat touches you

Page 4: Central Heating Management System

Common heating issues

The majority of households in the UK have inefficient central heating systems!

Bad circulation

Sludge and other deposits in water

Inadequate flow rate

Poor flow rate due to restrictions imposed by the

system boiler andbalancing

Air in system

Causes noise

Causes blockages

Causes cool spots on radiators

Causes corrosion

Causes time consuming radiator bleeding

Boiler inefficiencies

Sludge cuts boiler lifespan

Sludge can invalidate boiler warranty

Condensing boilers not working to full design

efficiency

In the press

Page 5: Central Heating Management System

In the press

News features from 2013 and 2014

Page 6: Central Heating Management System

Common heating layouts

Open Vented System (unpressurised)

System Boiler (pressurised)

Combi Boiler (pressurised)

Themarketplace

Page 7: Central Heating Management System

Themarketplace

CHMS A2A A2W

No External Noise

Yes No No

No large outside units Yes No No

No disturbance to neighbours Yes No No

Not reliant on air temperature Yes No No

Small and Discrete Yes No No

Eradicates common heating ailments Yes No No

Automatically bleeds air from system Yes No No

Make use of existing radiators without resizing Yes N/A No

Suitable for all Wet Central Heating Systems Yes N/A No

Annual Maintenance Required No Yes Yes???

Page 8: Central Heating Management System

What is the Central Heating

Management System?

A system, which at it heart includes the innovative Magic Heating Box™ which is proprietary to the Magic Thermodynamic Box Company.

Retro fitting to your current central heating system the CHMS comprises of a complete set of products including the Magic Heating BoxTM that ensures that there are no pinch points in the system with maximum water velocity and quantity without affecting the boiler. The result is that the whole surface of the radiator panel is now heated and utilised to its maximum, the radiator now releases its energy in the form of additional radiant heat as well as convected heat optimising the system.

Heating solutions

Page 9: Central Heating Management System

Heating solutions

The Central Heating Management System will help:

Bleed Air from System Reduces the need to bleed radiators in future

Reduce your Boiler to 60OC flow We will manually reduce the temperature flow

Make your Boiler work at maximum efficiency Give opportunity for condensing boiler to condense 100% of the time

Improve Heating Circulation Increased flow of water through radiators

Provide better heating into the room Enhances the way radiators work

Provide opportunity to reduce your fuel bills Save up to 30% on consumption

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

Page 10: Central Heating Management System

A whole heating

experience

The Globus®

ControllerThe Magic Heating Box®

The Globus®

Wall Thermostat

The Globus®

ThermostaticRadiator Valves

The Globus®

Two Port Valve

The Globus®

Circulation Pump

The Globus®

Lockshield Valves

The Globus®

Wiring BoxThe Globus®

Cleaner Liquid

The Pipe Thermostat

The Globus®

InhibitorValves

The Central Heating Management System is made up of all of the following components with the Magic Heating Box® at its heart. The MHB itself is fitted between the boiler and the heating system and is unique in its design. The system is not just a box!

AutomaticAir Valve

Page 11: Central Heating Management System

Before commencing the installation the existing system will be power flushed (cleansed) to ensure it is clean, using approved Globus®

Cleaner and Inhibitor Liquids, in accordance with BS7593.

Cleansing the

system

Removes harmful flux residues and debris

Removes black sludge (iron oxide) and limescale

Reduces fuel wastage and boiler noise

Long term protection against scale and corrosion

Protects boiler and prevents noise

Saves on fuel bills and maintenance

Symptoms which indicate your central heating systemis in need of a power flush

Cold water in

Hot water out

Water in

Feed & expansion cistern

Cold pipebecomingblocked by corrosionand scaledesposits

Repeated pumpfailures

Zonevalve

Boiler making loud and unpleasant noise especially

when working hardest

Radiators needfrequent bleeding

Radiators completelyor partially cold

Sludge build up

Radiators possibly bleeding

Sludgebuild up

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

Page 12: Central Heating Management System

The heatexchanger

A natural heat exchanger

5mm Stainless Steel

Lifetime Guarantee

ISO9001 & AS9100 standards

Tested to UKAS standards

Made in Great Britain

RADIATOR FLOW

RA

DIATOR RETU

RN

RADIATOR FLOW

RA

DIATOR RETU

RN

60c

RADIATOR FLOW

RAD

IATOR RETURN

RADIATOR FLOW

RAD

IATOR RETURN

RADIATOR FLOW

RADIATOR FLOW

60c

60c

RADIATOR FLOW

RAD

IATOR RETURN

RADIATOR FLOW

RAD

IATOR RETURN

60c 60c

Wall Thermostat

Controller

Circulation Pump

Boiler temp.reduced to 60OC

TRV

Magic HeatingBox®

AirVent

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

Page 13: Central Heating Management System

CHMScomponents

Certified German QualityFor high reliability, workmanship & quality

‘A’ rated efficiencyModern drive technology allows excellent energy efficiency

ErP readyDesigned to meet 2020 pump efficiency regulations

CIRCULATION PUMP

3 Zone Controller

Multi Programmable but only 3 buttons to run system

Large Blue Backlit Screen

Battery Backup

Automatic GMT/BST adjustment

PROGRAMMER

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

Page 14: Central Heating Management System

CHMScomponents

Contemporary Digital Touch Screen

Large Blue Backlighting

Accurate to ½ degree

Battery Backup

Automatic Frost Protection

Energy Saving Trust Recommended

WALL THERMOSTAT

Used to control water supply to the hot water cylinder

Motor On-Motor Off Design

Independently tested to be 96% more efficient thanconventional spring return valve design

Increased Reliability and Longer Working Life

TWO PORT VALVE

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

Page 15: Central Heating Management System

CHMScomponents

Temperature Settings from 7OC to 28OC

Easy to View Temperature Dial

Fitting includes anti-tamper feature

Liquid Filled Temperature Sensor for Faster Response

TRVs and LOCKSHIELDS

AUTOMATIC AIR VALVE

PIPE THERMOSTAT

25M CARPET PROTECTOR

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

Page 16: Central Heating Management System

Typical radiator

performance

WALL THERMOSTAT

Before Low Flow RateLockshields closed to balance system

After Increased Flow Lockshields fully open – no balancing required

Convectionheat circulating only

Warm face, cold feet

Radiated heatoutwards withthe addition ofconvection heat

Warm face, warm feet

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

SES Scottish Energy Saving

Whathappens

next

Page 17: Central Heating Management System

Whathappens

next

STEPONE

STEPTWO

STEPTHREE

STEPFOUR

Assessor’s visit Surveyor’s visit

Installation Post inspection visit