CB200 Conventional Control PanelsCB200 Conventional Control Panels

• Built-in detector removal indication facility 

• From 1 to 8 zones 

• 4 alarm circuits on 4-8 zone panels

• Conforms to the requirements of EN 54-2  

• User Friendly controls  

• One-man test facility 

• Non-latching zone feature 

• Class change input 

Page 2: CB200 Conventional Control Panels Built-in detector removal indication facility From 1 to 8 zones 4 alarm circuits on 4-8 zone panels Conforms to the requirements

CB200 Conventional Control PanelsCB200 Conventional Control Panels

• Earth Fault Monitoring (4 & 8 zone only – may

be disabled) 

• Fully-functional repeater available (4 & 8 zone

panels only) 

• Surface or semi-flush mounting as standard 

• Ample termination space 

• Flame Resistant Polycarbonate enclosure 

• Complies with EMC and LVD Directives

Page 3: CB200 Conventional Control Panels Built-in detector removal indication facility From 1 to 8 zones 4 alarm circuits on 4-8 zone panels Conforms to the requirements

Cabinet SpecificationsCabinet Specifications

Panel dimensions are detailed in the Application

Guide.

Panel dimensions are detailed in the Application

Guide.

The removable gland plate and cable entry grommets obviate the need to drill wiring

holes in the panel on site.

The removable gland plate and cable entry grommets obviate the need to drill wiring

holes in the panel on site.

Semi-flush is available as standard because of the

construction of the CB200 enclosure.

Semi-flush is available as standard because of the

construction of the CB200 enclosure.

Page 4: CB200 Conventional Control Panels Built-in detector removal indication facility From 1 to 8 zones 4 alarm circuits on 4-8 zone panels Conforms to the requirements

-

+

+

-

Mechanical AssemblyMechanical Assembly

This drawing shows the ample wiring space incorporated into

the CB200 panel design.

This drawing shows the ample wiring space incorporated into

the CB200 panel design.

Installer’s logo or brand

image may be added.

Installer’s logo or brand

image may be added.

Electronics are completely removable for convenience on site during fitting of the

back box.

Electronics are completely removable for convenience on site during fitting of the

back box.

PCB terminal support for mechanical reliability.

PCB terminal support for mechanical reliability.

There is space for two 12V 2.1AH batteries - suitable

for the 24hr standby requirements on an 8 zone

system.

There is space for two 12V 2.1AH batteries - suitable

for the 24hr standby requirements on an 8 zone

system.

Page 5: CB200 Conventional Control Panels Built-in detector removal indication facility From 1 to 8 zones 4 alarm circuits on 4-8 zone panels Conforms to the requirements

User ControlsUser Controls

This is a slide-in card to add text zone

identification.

This is a slide-in card to add text zone

identification.

Press 5 to access user controls and then press 14. Controls are

then enabled.

Repeat to disable controls.

Press 5 to access user controls and then press 14. Controls are

then enabled.

Repeat to disable controls.

General system LED indications.

General system LED indications.

Zone fire and fault LEDs.

Zone fire and fault LEDs.

Page 6: CB200 Conventional Control Panels Built-in detector removal indication facility From 1 to 8 zones 4 alarm circuits on 4-8 zone panels Conforms to the requirements

Typical Wiring Schematic Typical Wiring Schematic

This is a typical CB200 wiring

illustration as it appears in the

product documentation.

This is a typical CB200 wiring

illustration as it appears in the

product documentation.

Apollo S60 detectors are illustrated, but the CB200 panel supports a wide variety

of other manufacturers’ detectors - details in the Application Guide.

Apollo S60 detectors are illustrated, but the CB200 panel supports a wide variety

of other manufacturers’ detectors - details in the Application Guide.