catalogue - danfossfiles.danfoss.com/technicalinfo/dila/06/frcc.pk.039.a3.02_nov2014.pdf · petrol...

22
Optyma™ Slim Pack Just mount, connect piping and plug R404A/R507 - R134a - R22 - 50Hz Catalogue http://cc.danfoss.com

Upload: duongnhu

Post on 14-Sep-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Optyma™ Slim Pack Just mount, connect piping and plugR404A/R507 - R134a - R22 - 50Hz

Catalogue

http://cc.danfoss.com

Page 2: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02
Page 3: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Content

The new outdoor packaged solution .................................................................................................. 4

Features and cooling capacity ............................................................................................................. 5

Main product features .......................................................................................................................................................5

Condensing unit R404A/R507 LBP ..................................................................................................... 6

Condensing unit R22 MBP ................................................................................................................... 8

Condensing unit R404A/R507 MBP ................................................................................................... 10

Condensing unit R134a MBP ............................................................................................................. 12

Spare parts & accessories MBP ......................................................................................................... 14Electrical characteristics - 230V/1phase/50Hz ....................................................................................................... 14Electrical characteristics - 400V/3phase/50Hz ....................................................................................................... 14Spare parts .......................................................................................................................................................................... 14

Spare parts & accessories LBP .......................................................................................................... 15Electrical characteristics - 230V/1phase/50Hz ....................................................................................................... 15Electrical characteristics - 400V/3phase/50Hz ....................................................................................................... 15Spare parts .......................................................................................................................................................................... 15

Dimensions ......................................................................................................................................... 16Housing B3 ......................................................................................................................................................................... 16Housing B2 ......................................................................................................................................................................... 16

Electrical wiring diagrams ................................................................................................................. 17

Designation system ............................................................................................................................ 20Select the right Danfoss OptymaTM Slim Pack condensing unit according to your needs..................... 20

R404

A/R

507

R22

R134

a

3FRCC.PK.039.A3.02

Catalogue

Page 4: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

The new outdoor packaged solution

AB

C

D

E

Increased efficiency & sustainable solutions

Increase business opportunity with the new outdoor solution

Compact and light for easy handling and transportation

Well-known Danfoss quality and standards

With the OptymaTM Slim Pack substantial energy savings can be achieved thanks to micro channel condenser. You are going to reduce the energy consumption significantly and therefore, cut the energy bills.

System designed to perfectly fit into a compact and light housing. The OptymaTM Slim Pack weights up to 87 kg, which makes it the lightest solution in the market.

We provide the units with highly reliable compressors, micro channel heat exchangers and all needed components which are pre-assembled, integrated and factory tested. We at Danfoss do not accept any compromise regarding reliability or quality of our products.

Thanks to weatherproof housing the OptymaTM Slim Pack meets outdoor application requirements and completes the OptymaTM range. It is specially designed for high ambient operations.

Easy installation and cleaning

With quick connections of suction & liquid lines & service ports outside OptymaTM Slim Pack is among the fastest & easiest to install. Easy to clean MCHE saves your time & efforts, ensuring longer lifetime & optimized efficiency.

Stock and logistics optimization

Multirefrigerant condensing units with optimized packaging cover a wide variety of applications and reduce your stock. They can be used with R22, R404A/R507, R134a. Pick what best fits your application.

MBP and LBP applications:Mini-markets/supermarketsMilk coolingDairy and general food storage RestaurantsFish marketsBakeriesLaboratoriesFloristsPetrol stationsIndustrial processesWine cellarsCold roomsFreezers

4 FRCC.PK.039.A3.02

Catalogue

Page 5: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Features and cooling capacity

• Weatherproof housing IP54• Robust and resistant to corrosion• Compact design

• Easy & fast cleaning• Less refrigerant charge• Longer life time• High efficiency

• Fast and easy installation• Quick connections of suction & liquid lines• Shut off valves on receiver and service valves on service ports for easier & quick servicing

Conditions: LBP MBP• Ambient temperature: 43°C 43°C• Evaporating temperature: -25°C -5°C

Cooling capacity range (kW)

3.2

3.7

MBP - R404A/R507

MBP - R22

2.4MBP - R134a

Stor

age

of fr

esh

food

and

di

ary

appl

icat

ions

10.5

11.6

7.4

OptymaTM Slim Pack units can work in the following evaporating temperature range: MBP R22, R404A/R507 -20°C to +10°C MBP R134a -15°C to +15°C LBP R404A/R507 -40°C to -10°CFor further detailed information, please contact Danfoss.

Micro channel heat exchangerOutdoor application Service ports outside

Main product features

Free

zing

and

stor

age

of fo

od

1.4LBP - R404A

4.7

R404

A/R

507

R22

R134

a

5FRCC.PK.039.A3.02

Catalogue

Page 6: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Condensing unit R404A/R507 LBP

Fan Test

co

nditi

ons

UnitVersion Electrical

code

Com

pres

sor

Amb. temp.

°C

Cooling capacity range in (W) at evaporating temperature (°C)

Power consumption (W) at evap.

temp.-25°C

Sound power level dB(A)

Sound pressure level full sphere

1m dB(A)W04 -40°C -35°C -30°C -25°C -20°C -15°C -10°C

SH 10K

OP-LPHE048114X7053 G

NTZ048

32 650 1000 1400 1850 2400 3000 3650

1600 71 6038 550 850 1200 1600 2050 2600 3200

114X7054 E43 450 700 1000 1400 1800 2250 280046 350 600 900 1250 1650 2050 2550

OP-LPHE068114X7055 G

NTZ068

32 1200 1650 2200 2800 3500 4250 5100

2400 71 6038 950 1400 1850 2400 3050 3700 4500

114X7056 E43 800 1200 1600 2100 2650 3300 395046 750 1050 1450 1950 2450 3000 3650

OP-LPHE067 114X7057 E LLZ013

32 2050 2650 3350 4150 5100 6200 7450

3650 71 6038 1800 2350 3000 3750 4600 5600 670043 1600 2100 2700 3400 4150 5050 610046 1950 2500 3150 3900 4750 5700

OP-LPHE084 114X7058 E LLZ015

32 2500 3200 4000 5000 6150 7500 9000

4250 73 6238 2200 2850 3600 4500 5500 6700 8100

43 2000 2550 3250 4050 4950 6050 7300

46 2400 3000 3750 4650 5650 6800

OP-LPHE098 114X7059 E LLZ018

32 2900 3700 4650 5800 7100 8650 10350

4750 74 6338 2600 3300 4200 5200 6350 7750 930043 2300 2950 3750 4650 5750 6950 835046 2750 3500 4350 5350 6500 7800

Test condition Superheat 10K Electrical codeEN13215 E Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G Compressor 230V/1phase/50Hz, fan 230V/1phase/50 HzSubcooling within the limits of the condensing unit LLZ type compressor models are scroll compressors Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value.

Power consumption referred at 43°C ambient temperature

6 FRCC.PK.039.A3.02

Catalogue

Page 7: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Condensing unit R404A/R507 LBP

Unit

Condenser coil Condenser fan

Fan blade Ø (mm)

Receiver volume

(L)

Dimensions (mm) Weight (kg)

Type Air flow (m3/h)

Int. volume

(dm3)Housing Height H

(mm)Width W

(mm)Depth D

(mm)Suction

lineLiquid

line Gross Net

OP-LPHE048 D7 5100 0.6 457 3.4 B2 695 1106 464 5/8" 1/2" 76 61

OP-LPHE068 D7 5100 0.6 457 3.4 B2 695 1106 464 5/8" 1/2" 78 63

OP-LPHE067 G7 8700 1.8 600 6.2 B3 830 1106 464 3/4" 1/2" 92 75

OP-LPHE084 G7 8700 1.8 600 6.2 §B3 830 1106 464 3/4" 1/2" 92 75

OP-LPHE098 G7 8700 1.8 600 6.2 B3 830 1106 464 3/4" 1/2" 92 75

R404

A/R

507

7FRCC.PK.039.A3.02

Catalogue

Page 8: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Condensing unit R22 MBP

Fan Test

co

nditi

ons

UnitVersion

Electrical code

Com

pres

sor

Amb. temp.

°C

Cooling capacity range in (W) at evaporating temperature (°C)

Power consumption (W) at evap.

temp.-5°C

Sound power level dB(A)

Sound pressure level full sphere

1m dB(A)

W02 W04 -20°C -15°C -10°C -5°C 0°C +5°C +10°C

SH 10K

OP-MPUE034114X7015 114X7038 G

MLZ015

32 2300 2900 3500 4150 4950 5800 6750

2050 69 5838 2200 2700 3250 3900 4600 5400 6300

114X7016 114X7039 E43 2500 3050 3650 4350 5100 595046 2950 3500 4150 4900 5700

OP-MPME048

114X7026 114X7049 GMT028

32 2400 3150 3950 4900 5900 7000 8200

2350 71 6038 2100 2800 3600 4450 5400 6450 7550

114X7027 114X7050 E43 2550 3300 4100 5000 6000 700046 3100 3900 4750 5700 6700

OP-MPUE046114X7017 114X7040 G

MLZ021

32 3250 3950 4700 5550 6500 7550 8750

2800 69 5838 3000 3650 4350 5150 6050 7050 8150

114X7018 114X7041 E43 3400 4100 4800 5650 6600 765046 3900 4600 5400 6300 7300

OP-MPME060

114X7028 114X7051 GMT036

32 3050 3900 4900 5950 7100 8350 9650

3100 73 6238 2650 3500 4450 5450 6500 7650 8900

114X7029 114X7052 E43 3150 4050 5000 6000 7100 820046 3800 4700 5700 6750 7850

OP-MPUE057114X7073 G

MLZ026

32 3800 4700 5650 6700 7900 9250 10750

3500 69 5838 3500 4350 5250 6250 7350 8600 9950

114X7074 E43 4100 4900 5850 6850 8000 925046 4700 5600 6550 7650 8850

OP-MPUE068114X7019 114X7042 G

MLZ030

32 4850 6000 7400 8950 10650 12500 14550

3950 70 5938 4500 5600 6950 8400 10050 11850 13750

114X7020 114X7043 E43 5250 6500 7950 9500 11250 1310046 6250 7650 9150 10850 12650

OP-MPUE080114X7021 114X7044 G

MLZ038

32 5550 6950 8550 10400 12400 14550 16750

4650 70 5938 5250 6500 8050 9800 11650 13700 15850

114X7022 114X7045 E43 6100 7550 9200 11050 13000 1505046 7250 8850 10650 12550 14550

OP-MPUE093114X7023 114X7046 G MLZ042

32 6450 8000 9900 12050 14450 17000 19750

5550 70 5938 5900 7350 9100 11150 13450 15900 18500

114X7024 114X7047 E MLZ04543 6800 8450 10400 12600 14950 1750046 8050 9950 12050 14400 16900

OP-MPUE108 114X7025 114X7048 E MLZ048

32 7350 9050 11000 13200 15650 18350 21350

6150 70 5938 6850 8450 10300 12350 14650 17150 1990043 7900 9650 11550 13650 16050 1860046 9200 11000 13050 15300 17800

Test condition Superheat 10K Electrical codeEN13215 E Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G Compressor 230V/1phase/50Hz, fan 230V/1phase/50 HzSubcooling within the limits of the condensing unit MLZ type compressor models are scroll compressors Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value.

Power consumption referred at 43°C ambient temperature

8 FRCC.PK.039.A3.02

Catalogue

Page 9: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Condensing unit R22 MBP

Unit

Condenser coil Condenser fan

Fan blade Ø (mm)

Receiver volume

(L)

Dimensions (mm) Weight (kg)

Type Air flow (m3/h)

Int. volume

(dm3)Housing Height H

(mm)Width W

(mm)Depth D

(mm)Suction

lineLiquid

line Gross Net

OP-MPUE034 D7 5100 0.6 457 3.4 B2 695 1106 464 3/4" 1/2" 74 66

OP-MPME048 D7 5100 0.6 457 3.4 B2 695 1106 464 5/8" 1/2" 66 58

OP-MPUE046 D7 5100 0.6 457 3.4 B2 695 1106 464 3/4" 1/2" 74 66

OP-MPME060 D7 5100 0.6 457 3.4 B2 695 1106 464 5/8" 1/2" 68 60

OP-MPUE057 D7 5100 0.6 457 3.4 B2 695 1106 464 3/4" 1/2" 74 66

OP-MPUE068 G7 8700 1.8 600 6.2 B3 830 1106 464 7/8" 1/2" 96 87

OP-MPUE080 G7 8700 1.8 600 6.2 B3 830 1106 464 7/8" 1/2" 96 87

OP-MPUE093 G7 8700 1.8 600 6.2 B3 830 1106 464 7/8" 1/2" 96 87

OP-MPUE108 G7 8700 1.8 600 6.2 B3 830 1106 464 7/8" 1/2" 96 87

R22

9FRCC.PK.039.A3.02

Catalogue

Page 10: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Condensing unit R404A/R507 MBP

Fan Test

co

nditi

ons

UnitVersion

Electrical code

Com

pres

sor

Amb. temp.

°C

Cooling capacity range in (W) at evaporating temperature (°C)

Power consumption (W) at evap.

temp.-5°C

Sound power level dB(A)

Sound pressure level full sphere

1m dB(A)

W02 W04 -20°C -15°C -10°C -5°C 0°C +5°C +10°C

SH 10K

OP-MPUE034114X7015 114X7038 G

MLZ015

32 2250 2800 3450 4100 4900 5700 6650

2300 69 5838 1950 2450 3000 3650 4300 5100 5900

114X7016 114X7039 E43 1650 2100 2650 3200 3850 4550 530046 2450 2450 2450

OP-MPUE046114X7017 114X7040 G

MLZ021

32 3150 3800 4550 5400 6350 7400 8550

3100 69 5838 2750 3350 4050 4800 5650 6600 7650

114X7018 114X7041 E43 2450 3000 3600 4300 5050 5950 690046 3300 3950 4700

OP-MPUE057114X7073 G

MLZ026

32 3750 4550 5400 6400 7450 8600 9850

4000 69 5838 3300 4000 4750 5650 6600 7650 8800

114X7074 E43 2850 3500 4200 4950 5850 6800 785046 3800 4550 5350

OP-MPUE068114X7019 114X7042 G

MLZ030

32 5000 6200 7500 9000 10650 12550 14650

4400 70 5938 4450 5550 6700 8100 9600 11350 13300

114X7020 114X7043 E43 3950 4950 6050 7300 8700 10300 1210046 5600 6800 8150

OP-MPUE080114X7021 114X7044 G

MLZ038

32 5950 7250 8750 10450 12400 14550 16900

5200 70 5938 5250 6450 7800 9350 11150 13100 15300

114X7022 114X7045 E43 4650 5750 7000 8450 10050 11850 1390046 6500 7850 9350

OP-MPUE093114X7023 114X7046 G MLZ042

32 6950 8500 10250 12200 14400 16850 19500

6400 70 5938 6150 7550 9100 10900 12900 15150 17600

114X7024 114X7047 E MLZ04543 5450 6700 8100 9750 11600 13650 1595046 6650 6750 6900

OP-MPUE108 114X7025 114X7048 E MLZ048

32 7550 9150 11000 13100 15400 18000 20850

6900 70 5938 6650 8150 9800 11650 13750 16150 1880043 5850 7200 8700 10450 12350 14550 1700046 8050 9650 11500

Test condition Superheat 10K Electrical codeEN13215 E Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G Compressor 230V/1phase/50Hz, fan 230V/1phase/50 HzSubcooling within the limits of the condensing unit MLZ type compressor models are scroll compressors Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value.

Power consumption referred at 43°C ambient temperature

10 FRCC.PK.039.A3.02

Catalogue

Page 11: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Condensing unit R404A/R507 MBP

Unit

Condenser coil Condenser fan

Fan blade Ø (mm)

Receiver volume

(L)

Dimensions (mm) Weight (kg)

Type Air flow (m3/h)

Int. volume

(dm3)Housing Height H

(mm)Width W

(mm)Depth D

(mm)Suction

lineLiquid

line Gross Net

OP-MPUE034 D7 5100 0.6 457 3.4 B2 695 1106 464 3/4" 1/2" 74 66

OP-MPUE046 D7 5100 0.6 457 3.4 B2 695 1106 464 3/4" 1/2" 74 66

OP-MPUE057 D7 5100 0.6 457 3.4 B2 695 1106 464 3/4" 1/2" 74 66

OP-MPUE068 G7 8700 1.8 600 6.2 B3 830 1106 464 7/8" 1/2" 96 87

OP-MPUE080 G7 8700 1.8 600 6.2 B3 830 1106 464 7/8" 1/2" 96 87

OP-MPUE093 G7 8700 1.8 600 6.2 B3 830 1106 464 7/8" 1/2" 96 87

OP-MPUE108 G7 8700 1.8 600 6.2 B3 830 1106 464 7/8" 1/2" 96 87

R404

A/R

507

11FRCC.PK.039.A3.02

Catalogue

Page 12: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Condensing unit R134a MBP

Fan Test

co

nditi

ons

UnitVersion

Electrical code

Com

pres

sor

Amb. temp.

°C

Coling capacity range in (W) at evaporating temperature (°C)

Power consumption (W) at evap.

temp.-5°C

Sound power level dB(A)

Sound pressure level full sphere

1m dB(A)

W02 W04 -15°C -10°C -5°C 0°C +5°C +10°C

SH 10K

OP-MPUE034114X7015 114X7038 G

MLZ015

32 1750 2200 2700 3300 4000 4800

1350 69 5838 1600 2050 2500 3100 3750 4500

114X7016 114X7039 E43 1900 2350 2900 3550 425046 1800 2250 2800 3400 4100

OP-MPUE046114X7017 114X7040 G

MLZ021

32 2350 2900 3600 4400 5350 6350

1750 69 5838 2150 2700 3350 4100 5000 5950

114X7018 114X7041 E43 2550 3150 3850 4700 560046 2450 3000 3700 4500 5400

OP-MPUE057114X7073 G

MLZ026

32 2800 3550 4400 5350 6400 7600

2150 69 5838 2600 3300 4050 4950 6000 7100

114X7074 E43 3050 3800 4650 5600 670046 2900 3650 4450 5350 6400

OP-MPUE068114X7019 114X7042 G

MLZ030

32 3550 4500 5600 6900 8350 10050

2700 70 5938 3300 4200 5250 6450 7850 9450

114X7020 114X7043 E43 3950 4900 6050 7400 890046 3800 4700 5850 7100 8600

OP-MPUE080114X7021 114X7044 G

MLZ038

32 4150 5250 6550 8050 9750 11650

3200 70 5938 3850 4900 6100 7500 9100 10950

114X7022 114X7045 E43 4550 5700 7050 8600 1030046 4350 5500 6800 8250 9950

OP-MPUE093114X7023 114X7046 G MLZ042

32 5100 6450 8000 9850 11900 14200

3650 70 5938 4750 5950 7450 9200 11150 13350

114X7024 114X7047 E MLZ04543 5550 6950 8600 10450 1255046 5350 6650 8250 10050 12050

OP-MPUE108 114X7025 114X7048 E MLZ048

32 5400 6800 8450 10350 12500 14900

3900 70 5938 5000 6300 7850 9650 11700 1395043 5900 7350 9050 11000 1315046 5650 7050 8650 10550 12650

Test condition Superheat 10K Electrical code EN13215 E Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G Compressor 230V/1phase/50Hz, fan 230V/1phase/50 HzSubcooling within the limits of the condensing unit MLZ type compressor models are scroll compressors Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value. Power consumption referred at 43°C ambient temperature

12 FRCC.PK.039.A3.02

Catalogue

Page 13: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Condensing unit R134a MBP

UnitCondenser coil Condenser

fanFan blade Ø

(mm)

Receiver volume

(L)

Dimensions (mm) Weight (kg)

Type Air flow (m3/h)

Int. volume

(dm3)Housing Height H

(mm)Width W

(mm)Depth D

(mm)Suction

lineLiquid

line Gross Net

OP-MPUE034 D7 5100 0.6 457 3.4 B2 695 1106 464 3/4" 1/2" 74 66

OP-MPUE046 D7 5100 0.6 457 3.4 B2 695 1106 464 3/4" 1/2" 74 66

OP-MPUE057 D7 5100 0.6 457 3.4 B2 695 1106 464 3/4" 1/2" 74 66

OP-MPUE068 G7 8700 1.8 600 6.2 B3 830 1106 464 7/8" 1/2" 96 87

OP-MPUE080 G7 8700 1.8 600 6.2 B3 830 1106 464 7/8" 1/2" 96 87

OP-MPUE093 G7 8700 1.8 600 6.2 B3 830 1106 464 7/8" 1/2" 96 87

OP-MPUE108 G7 8700 1.8 600 6.2 B3 830 1106 464 7/8" 1/2" 96 87

R134

a

13FRCC.PK.039.A3.02

Catalogue

Page 14: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Spare parts & accessories MBP

Electrical characteristics - 230V/1phase/50Hz

Unit

Wiring diagram LRA compressor (A)

230 V/ 1 phase

MCC compressor(A)

230 V/ 1 phaseMax cont. power

consumption (kW)MCC Fan

(A)230 V/ 1 phase

Fan Power(W)

W02 W04

OP-MPUE034ML

WD 1

WD 3

60 19 2.86

1.1 135

OP-MPME048MT 51 20 3.46

OP-MPUE046ML 97 25 3.61

OP-MPME060MT 60 22 4.51

OP-MPUE057ML - 97 26 4.38

OP-MPUE068ML

WD 1

127 32 5.70

3.0 370OP-MPUE080ML 130 38 6.72

OP-MPUE093ML 130 40 8.40

Note: LRA (Locked Rotor Amps), MCC (Maximum Continuous Current)

Spare parts

UnitCompressor

Filter drier Sight glassSolenoid valve

Receiver (L) CondenserModel 1 phase 3 phases (body) (coil)

OP-MPUE034 MLZ015 121U8024 121U8002

DML084 DCL084

023Z5041 023Z5006

SGN+12SGP 12 N

014F0173014L0163

EVR 10 032F1217 018F67013.4 118U3475 118U3493

OP-MPME048 MT028 MT28-5VI MT28-4VI

OP-MPUE046 MLZ021 121U8028 121U8006

OP-MPME060 MT036 MT36-5VI MT36-4VI

OP-MPUE057 MLZ026 121U8030 121U8008 -

OP-MPUE068 MLZ030 121U8032 121U8010

DML164 DCL164

023Z5044 023Z5009

SGN+12sSGP 12s

N014F0183014L0183 EVR 10 032F1217 018F6701 6.2 118U3476 118U3494

OP-MPUE080 MLZ038 121U8034 121U8012

OP-MPUE093 MLZ042/MLZ045 121U8419 121U8014

OP-MPUE108 MLZ048 - 121U8016

Spare parts

UnitFan motor (W)

(capacitor included)

Fan blade (inch) Fan grill Suction valve Liquid valve LP pressure cartridge

HP pressure cartridge

OP-MPUE034

135 118U3765 18" 118U3766 B2 118U3484

3/4" 118U3759

1/2" 118U3758 ACB-2UA595W 061F7595 ACB-

2UB246W 061F8215

OP-MPME048 5/8" 118U3760

OP-MPUE046 3/4" 118U3759

OP-MPME060 5/8" 118U3760

OP-MPUE057 3/4" 118U3759

OP-MPUE068

370 118U3767 24" 118U3768 B3 118U3485 7/8" 118U3757OP-MPUE080

OP-MPUE093

OP-MPUE108

Electrical characteristics - 400V/3phase/50Hz

UnitWiring diagram LRA compressor

(A)400 V/ 3phase

MCC compressor(A)

400 V/ 3phaseMax cont. power

consumption (kW)MCC Fan

(A)230 V/ 1 phase

Fan Power(W)

W02 W04

OP-MPUE034ML

WD 2

WD 4

30 7 2.79

1.1 135

OP-MPME048MT 23 7.5 3.46

OP-MPUE046ML 45 9.5 3.85

OP-MPME060MT 30 9 4.51

OP-MPUE057ML - 45 10 4.36

OP-MPUE068ML

WD 2

60 13 5.63

3.0 370OP-MPUE080ML 70 15 6.64

OP-MPUE093ML 82 15 7.81

OP-MPUE108ML 87 16 8.46

Note: LRA (Locked Rotor Amps), MCC (Maximum Continuous Current)

14 FRCC.PK.039.A3.02

Catalogue

Page 15: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Spare parts & accessories LBP

Electrical characteristics - 230V/1phase/50Hz

Unit

Wiring diagram LRA compressor (A)

230 V/ 1 phase

MCC compressor(A)

230 V/ 1 phaseMax cont. power

consumption (kW)MCC Fan

(A)230 V/ 1 phase

Fan Power(W)

W04

OP-LPHE048WD 5

37 11 2.331.1 135

OP-LPHE068 53 17 3.76

Note: LRA (Locked Rotor Amps), MCC (Maximum Continuous Current)

Electrical characteristics - 400V/3phase/50Hz

UnitWiring diagram LRA compressor

(A)400 V/ 3phase

MCC compressor(A)

400 V/ 3phaseMax cont. power

consumption (kW)MCC Fan

(A)230 V/ 1 phase

Fan Power(W)

W04

OP-LPHE048

WD 6

16 4.8 2.411.1 135

OP-LPHE068 25 8.4 3.70

OP-LPHE067 62 12 5.03

3.0 370OP-LPHE084 88.5 15 5.94

OP-LPHE098 90 14.4 6.65

Note: LRA (Locked Rotor Amps), MCC (Maximum Continuous Current)

Spare parts

UnitCompressor

Filter drier Sight glass Receiver (L) Condenser Crankcase heaterModel 1 phase 3 phases

OP-LPHE048 NTZ048 120F0087 120F0001 DML084S DCL084S

023Z5061 023Z5026

SGN+12 SGP 12 N

014F0173 014L0163 3.4 118U3475 118U3493 PTC 35W 120Z0459

OP-LPHE068 NTZ068 120F0088 120F0002

OP-LPHE067 LLZ013 - 121L9517DML164S DCL164S

023Z5067 023Z5032

SGN+12s SGP 12s N

014F0183 014L0183 6.2 118U3476 118U3494 Belt 70 W 120Z5040OP-LPHE084 LLZ015 - 121L9513

OP-LPHE098 LLZ018 - 121L9509

Spare parts

Unit Fan motor (W)(capacitor included) Fan blade (inch) Fan grill Suction valve Liquid valve LP pressure

cartridgeHP pressure

cartridge

OP-LPHE048135 118U3765 18" 118U3766 B2 118U3484 5/8" 118U3764

1/2" 118U3761 ACB-2UA947W 061F 7798 ACB-

UB1209W 061F 6365

OP-LPHE068

OP-LPHE067

370 118U3767 24” 118U3768 B3 118U3485 3/4" 118U3762OP-LPHE084

OP-LPHE098

R404

A/R

507

R22

R134

a

15FRCC.PK.039.A3.02

Catalogue

Page 16: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Dimensions

750MOUNTING C/C

1035

444

MO

UN

TIN

G C

/C

431

UN

IT D

EP

TH69

0U

NIT

HE

IGH

T

�10 H

OLES

FOR MOUNTIN

G

TOP VIEW

30GRILLEHEIGHT

52SERVICE VALVEHEIGHT

AIRIN

AIROUT

ISO VIEW

MCHXCABLE ENTRYPORTS

SUCTION PORT

LIQUID PORT

FRONT VIEWLH VIEW RH VIEW BACK VIEW

200TYP.

464

750MOUNTING C/C

444

1035UNIT WIDTH

431

UN

IT D

EP

TH

�10 H

OLES

FOR MOUNTIN

G

TOP VIEW

MO

UN

TIN

G C

/C

38GRILLEHEIGHT

70SERVICE VALVE

HEIGHT

825

UN

IT H

EIG

HT

200 TYP.

464

AIRIN

AIROUT

LH VIEW FRONT VIEW RH VIEW BACK VIEW

ISO VIEW

MCHXCABLE ENTRYPORTS

SUCTION PORT

LIQUID PORT

Housing B2

Housing B3

16 FRCC.PK.039.A3.02

Catalogue

Page 17: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Electrical wiring diagrams

P<>2

1

-B3*BN

BU

12

11

8

BU

9

BK

10

5

BK

BK

PRESSURELOW

PRESSUREHIGH

P<-B2

P>-B17

6 BK

4

3

SOLENOIDVALVE

BN

BU

230VAC

PE

2

1

..

OptionStandard

-C1

BK

WH

BU

M1~

C

S R

-M1

GY

U

V

5

2

1

-K1

RD-R1

-C2

COMPRESSOR

C*

S*

R*

BN

PE

A1

A2

-Y1

FAN SPEEDCONTROLLER

M1~

S

-M2

FAN

-R1ResistorSTART RELAY

-K1/TYPECAPACITORS 450V

-C2/MFD-C1/MFDcm 3

DISPLACEMENTMODEL

COMPRESSORTYPE/TYP/TYPECODE

2

1

-E1*BN

BU

CRANKCASE HEATERMLZ-compr.

88-108081

093

MLZ030T5LC9

MLZ038T5LC9

MLZ042T5LC9

114X7019

114X7021

114X7023

3AAR3*3M*

50

55

3ARR3J24AP4

15kOhm

114X7015

114X7017

MPUE034MLW02G

MPUE046MLW02G

MLZ015T5LP9

MLZ021T5LP9

034

046

114X7026

114X7028

MPME048MTW02G

MPME060MTW02G

MT28-5VM

MT36-5VM

048

061

100

135

145-175

161-193

3ARR3J4A4/RVA6AMKL

3ARR3J3AL4/RVA9CKL

/RVA4GKL

/RVA3EKL

30

35

70

40

*: Option

069MPUE068MLW02G

MPUE093MLW02G

MPUE080MLW02G

K2*

K3*

Q1* F1*

L N CONTR.

S1* T>

T<S2*

K3* K2*

..

CONTR.L3 NL2L1

PE

8

BU

9 M1~

S

-M2

FANBK

10OptionStandard

5

BK

BK

PRESSURELOW

PRESSUREHIGH

P<-B2

P>-B17

6 BK

4

3

BN

BU

230VAC

PE

2

1

U

V

W

COMPRESSOR

M

T1 T3T2

3~-M1

BU

11

FAN SPEEDCONTROLLERP<>

2

1

-B3*

BN

12

BN

034

046

069

081

MODEL cm 3

COMPRESSOR DISPLACEMENT

MLZ015T4LP9

MLZ021T4LP9

MLZ030T4LC9

MLZ038T4LC9

MLZ048T4LC9 108

093MLZ045T4LC9

048

061

MT28-4VM

MT36-4VM

MPUE034MLW02E

MPUE080MLW02E

MPME048MTW02E

MPUE046MLW02E

MPUE068MLW02E

MPUE093MLW02E

MPUE108MLW02E

MPME060MTW02E

TYPE/TYP/TYPECODE

114X7016

114X7018

114X7020

114X7022

114X7024

114X7025

114X7027

114X7029

SOLENOIDVALVE

A1

A2

-Y1

BK

GY

MLZ-compr.CRANKCASE HEATER

MT-compr.BN

BU

BN

BU 2

1

-E1*

2

1

-E1*

Option*:

Q1* F1*

K3*

K2*

S1* T>

T<S2*

K3* K2*

Code G (version W02): OP-MPUE034 - 046 - 068 - 080 - 093 & OP-MPME048 - 060

Code E (version W02) : OP-MPUE034 - 046 - 068 - 080 - 093 - 108 & OP-MPME048 - 060

LegendBK blackBU blueBN brown GY greyRD redWH white

B1 High Pressure SwitchB2 Low Pressure SwitchB3* Fan Speed Controller C1 Run capacitor compressorC2 Start capacitor compressorE1* Crankcase heater

F1* Fuse (control circuit)M1 CompressorM2 Fan motorK1 Start relayK2* Compressor contactorK3* Fan contactor

Q1* Main switchS1* Thermostat (cold room)S2* Thermostat (crankcase heater)Y1 Solenoid valve

R404

A/R

507

R22

R134

a

17FRCC.PK.039.A3.02

Catalogue

Page 18: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Electrical wiring diagrams

BK

2 43

BN

BN

BN

BN

1N2

3A

1

2

-F3

21

22

-K195

96

97

98

N1

A1

A2

-K1

7 8 9

BK

BK

BK

BK

BN

BN

5 6 11

PE-X1

BL

BN

*

GNYE

BN

BK

BU

BN

BKBU

P

1

2

PE

-B1*

P<-B3

P>-B2

A1

A2PE

-Y1

10

MG73BF SM500

16 18 15

L1L2L3

PN

26 28 25

-A1

PE-X1

2

1

-E1* M1~-M2

setting/Einstellung/ajustage -F2

CodevalueWertvaleur

Bereichrange

domainetype/Typ/type

BK

BN

GY

PE-X1

M1~

S C R

-M1

S C R

-C2

-R2

WH

-C1 -R1

RD

5

2

15

-K2

* * *

230V1N~/50Hz

L PEN

BN

-F1

BU

Option*:

114X7073114X7042114X7044114X7046

32A38A

26A23-32A30-38A

23-32A

30-40A 40A

MPUE057MLW04GMPUE068MLW04GMPUE080MLW04GMPUE093MLW04G

114X7038114X7040

MPUE034MLW04GMPUE046MLW04G

16-24A23-32A 25A

19A

114X7049114X7051

MPME048MTW04GMPME060MTW04G

20A22A

16-24A16-24A

1

2

3

4

5

6-K1

xxA

5

6

3

4

1

2

-F2

BU

BN

BU

BK

2

A1

A2

-K1

43N2

BK

BN

BN

BN

N3

BU

BU

21

22

-K1

xxA

5

6

3

4

1

2

-F295

96

3A

1

2

-F31

2

3

4

5

6-K1

97

98

5 6

BN

7 8 9

BK

BK

BK

BK

BN

BN

P<-B3

PE-X1

*

11

A1

A2PE

-Y1BL

BN

GNYE

BK

1

BN

BN

P

1

2

PE

-B1*

P>-B2

MG73BF

16 18 15

L1L2L3

26 28 25

-A1

10

2

1

-E1*

BK

GY

BN

-F1

PE-X1

380-400V3N~/50Hz

L1 L2 PEL3 N

M3~-M1

BN

BK

GY

BU

PE-X1

M1~-M2

Bereichrange

domainetype/Typ/type

valueWertvaleur

setting/Einstellung/ajustage -F2

9,5A7,0A5,5-8A

7-10A

CODE

MPUE034MLW04EMPUE046MLW04E

114X7039114X7041

13A15A15A16A

9A7,5A5,5-8A

9-13A12-18A12-18A12-18A

7-10A

MPUE068MLW04EMPUE080MLW04EMPUE093MLW04EMPUE108MLW04EMPME048MTW04EMPME060MTW04E

114X7043114X7045114X7047114X7048114X7050114X7052

114X7074 MPUE057MLW04E 7-10A 10A-S1*

: Option*

Code G (version W04): OP-MPUE034 - 046 - 057 - 068 - 080 - 093 & OP-MPME048 - 060

Code E (version W04): OP-MPUE034 - 046 - 057 - 068 - 080 - 093 - 108 & OP-MPME048 - 060

LegendBK blackBU blueBN brown GY greyRD redWH white

B1* Fan Speed ControllerB2 High Pressure SwitchB3 Low Pressure Switch C1 Start capacitor compressorC2 Run capacitor compressorE1* Crankcase heater

F1, F3 Fuse (control circuit)F2 Overload relayM1 CompressorM2 Fan motorK1 ContactorK2 Start relay

R1, R2 Bleeder resistorS1* Thermostat X1 Terminals Y1* Solenoid valve

WD 3

WD 4

18 FRCC.PK.039.A3.02

Catalogue

Page 19: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Electrical wiring diagrams

117 8 9

BK BKBKBK

BNBN

BK

2 43

PE-X1

BN

BNBN

BKBN

1

A1

A2

-K1

P<-B3

BU

N2

21

22

-K1

BK

N1

xxA

5

6

3

4

1

2

-F295

96

97

98

3A

1

2

-F3

1

2

3

4

5

6-K1

BU

BN BU

BLBN

A1

A2PE

-Y1*

GNYE

5 6

BN

P

1

2

PE

-B1*

P>-B2

10

PE-X1

BN

-F1

BU -C2

-R2

-C1 -R1

5

2

15

-K2

BKBN GY

M1~

S C R

-M1

PE-X1

2

1

-E1 M1~-M2

230V1N~/50Hz

L PEN -S1*Bereichrange

domainetype/Typ/type

valueWertvaleur

setting/Einstellung/ajustage -F2

Code

114X7053114X7055

9-13A16-24A

11A17A

OP-LPHE048NTW04GOP-LPHE068NTW04G

MG73BF SM500

16 18 15

L1L2L3

PN

26 28 25

-A1

: Option*

xxA

5

6

3

4

1

2

-F295

96

3A

1

2

-F31

2

3

4

5

6-K1

97

98

BK BU BKBN

BU BN

21

22

-K1

BK

2 43

BN

BNBN

SM500

N1 N2 1

A1

A2

-K1

5 6

BN

PE-X1

7 8 9

BK BKBKBK

BNBN

P<-B3

*

11

BLBNA1

A2PE

-Y1

MG73BF

16 18 15

L1L2L3

26 28 25

-A1

P

1

2

PE

-B1*

P>-B2

10

PE-X1

2

1

-E1 M1~-M2

BK GYBN

BN BK GY

-F1

BU

PE-X1

M3~-M1

380-400V3N~/50Hz

L1 L2 PEL3 N

: Option*-S1*

Bereichrange

domainetype/Typ/type

valueWertvaleur

setting/Einstellung/ajustage -F2

CODE

114X7054114X7056114X7057114X7058114X7059

12-18A12-18A

4,8A8,4A12A15A15A

7-10A9-13A

4-6AOP-LPHE048NTW04EOP-LPHE068NTW04E

OP-LPHE098LLW04E

OP-LPHE067LLW04EOP-LPHE084LLW04E

Code G (version W04) : OP-LPHE048 - 068

Code E (version W04) : OP-LPHE048 - 068 - 067 - 084 - 098

LegendBK blackBU blueBN brown GY greyRD redWH white

B1* Fan Speed ControllerB2 High Pressure SwitchB3 Low Pressure Switch C1 Start capacitor compressorC2 Run capacitor compressorE1 Crankcase heater

F1, F3 Fuse (control circuit)F2 Overload relayM1 CompressorM2 Fan motorK1 ContactorK2 Start relay

R1, R2 Bleeder resistorS1* Thermostat X1 Terminals Y1* Solenoid valve

WD 5

WD 6

R404

A/R

507

R22

R134

a

19FRCC.PK.039.A3.02

Catalogue

Page 20: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Designation system

Select the right Danfoss OptymaTM Slim Pack condensing unit according to your needs

Model and cooling

capacity by cold room

type

Nominal HP

Meat +1°C - 18h

Fish +1°C - 18h

Laboratories +12°C - 18h

Fruits & vegetables +8°C - 18h

Fruits & vegetables

0°C - 18h

Butter, eggs & cheese

+5°C - 18hFreezers

-18°C - 16h

Cap.(W)

CR* (ft3)

Cap.(W)

CR* (ft3)

Cap.(W)

CR* (ft3)

Cap.(W)

CR* (ft3)

Cap.(W)

CR* (ft3)

Cap.(W)

CR* (ft3)

Cap.(W)

CR* (ft3)

OP-MPUE034 2.0 3720 1000 3720 1000 5360 2500 4700 1500 3590 1000 4410 1500

OP-MPME048 2.0 4190 1000 4190 1000 6040 2500 5300 1500 4050 1000 4970 1500

OP-MPUE046 3.0 4920 1750 4920 1750 7080 3500 6220 2750 4750 1750 5830 2750

OP-MPME060 3.0 5100 1750 5100 1750 7340 3500 6440 2750 4920 1750 6040 2750

OP-MPUE057 3.5 5520 2000 5520 2000 7950 4000 6980 3000 5330 2000 6550 3000

OP-MPUE068 4.0 8080 2750 8080 2750 11640 5500 10220 3500 7800 2750 9580 3500

OP-MPUE080 5.0 9400 3500 9400 3500 13530 7500 11880 6000 9070 3500 11140 6000

OP-MPUE093 6.0 10600 4500 10600 4500 15270 8500 13400 7000 10230 4500 12560 7000

OP-MPUE108 7.0 11770 6000 11770 6000 16950 10000 14880 8500 11360 6000 13950 8500

OP-LPHE048 1.5 1400 400

OP-LPHE068 2.0 2100 600

OP-LPHE067 3.5 3400 900

OP-LPHE084 5.0 4050 1500

OP-LPHE098 6.0 4650 1750

Data refers to +43°C ambient temperature, MBP R22, LBP R404ARefer to Danfoss for other refrigerants or different working conditionsApplication - Cold room temperature - Daily working hours* Volume of cold room in cubit feet

Designation system for the OptymaTM Slim Pack range (additional program frequency etc.: please contact your local wholesaler)

Optyma Condensing unit

ApplicationM: MBPL: LBP

PackageP: Packaged unit

RefrigerantU: R22/R134a/R404A M: R22H: R404A/R507

Condenser sizeE: extreme and tropical ambient conditions up to 48°C

Swept volume in CC

Voltage codesG: 230 V-1 ph compressor & fanE: 400 V-3 ph compressor & 230 V-1 ph fan

VersionW02: standard equipement for extreme conditionsW04: 02 including special electrical box

Compressor platformML: MLZ (scroll)MT: MT (reciprocating)NT: NTZ (reciprocating)LL: LLZ (scroll)

034

Swept volume

M

Application

OP

Optyma

ML

Compressor platform

W04

Version

E

Voltage code

U

Refrigerant

E

Condenser size

Package

P

20 FRCC.PK.039.A3.02

Catalogue

Page 21: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02
Page 22: Catalogue - Danfossfiles.danfoss.com/TechnicalInfo/Dila/06/FRCC.PK.039.A3.02_Nov2014.pdf · Petrol stations Industrial processes Wine cellars Cold rooms Freezers 4 FRCC.PK.039.A3.02

Danfoss Commercial Compressors is a worldwide manufacturer of compressors and condensing units for refrigeration and HVAC applications. With a wide range of high quality and innovative products we help your company to find the best possible energy efficient solution that respects the environment and reduces total life cycle costs.

We have 40 years of experience within the development of hermetic compressors which has brought us amongst the global leaders in our business, and positioned us as distinct variable speed technology specialists. Today we operate from engineering and manufacturing facilities spread across three continents.

FRCC.PK.039.A3.02 - November 2014 © Copyright Danfoss | Commercial Compressors | 2014.11

Our products can be found in a variety of applications such as rooftops, chillers, residential air conditioners, heatpumps, coldrooms, supermarkets, milk tank cooling and industrial cooling processes.

http://cc.danfoss.com

Danfoss Inverter Scrolls

Danfoss Turbocor Compressors

Danfoss Scrolls

Danfoss Optyma Condensing Units

Secop Compressors for Danfoss

Danfoss Maneurop Reciprocating Compressors

Danfoss Commercial Compressors, BP 331, 01603 Trévoux Cedex, France | +334 74 00 28 29