catalogue of leak test apparatus

5
Your Quality, Our Assurance Leak T esters

Upload: tixoc

Post on 07-Aug-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Catalogue of Leak Test Apparatus

8/20/2019 Catalogue of Leak Test Apparatus

http://slidepdf.com/reader/full/catalogue-of-leak-test-apparatus 1/4

Your Quality, Our Assurance

Leak Testers

Page 2: Catalogue of Leak Test Apparatus

8/20/2019 Catalogue of Leak Test Apparatus

http://slidepdf.com/reader/full/catalogue-of-leak-test-apparatus 2/4

LT - 101P

Meets USP and international package practiceŸ

specifications

Programmable vacuum level and hold timeŸ

Slow venting for better precisionŸ

Printout of validation reportŸ

GMP model also availableŸ

Oil-less vacuum pumpŸ

Features

12 mm round glass plate

for 250 mm dia desiccator

Part no - 5001A00001

Perforated disc for 300 mm

dia desiccator

Part no - 5001A00006

Perforated disc for 250 mm

dia desiccator

Part no - 5001A00005

12 mm round glass plate

for 300 mm dia desiccator

Part no - 5001A00002

Optional accessories

Model

Vacuum level range

Timer range

Power requirement

Power

Vacuum setting level

Dimensions (L x W x H)

Weight

2 mm Hg to 699 mm Hg

00.01 sec to 99 mins 59 secs

Vacuum stabilization to the set value of 5 mm Hg±

400 mm x 240 mm x 220 mm

Net : 17 Kg

Gross : 21 Kg

230 V. 50 Hz / 110 V. 50 / 60 Hz

300 VA

LT-101P

Printer interface Epson LX - 310

Specifications

Ideal for checking leakage of packed strips,

blisters, small sachets of tablets , capsules,

liquids, cough syrup, shampoo packets,

ampoules, sutures etc.

Leak Tester

 Methylene Blue Dye Test Method )

Page 3: Catalogue of Leak Test Apparatus

8/20/2019 Catalogue of Leak Test Apparatus

http://slidepdf.com/reader/full/catalogue-of-leak-test-apparatus 3/4

Specifications

Model

Vacuum level range

Timer range

Power requirement

Power

Vacuum setting level

Weighing balance

compatibility

Dimensions (L x W x H)

Mettler Toledo, Sartorious, Contech and Ohaus

ELT - 201W

Weight

2 mm Hg to 699 mm Hg

00.01 sec to 99 mins 59 secs

Vacuum stabilization to the set value of 5 mm Hg±

400 mm x 240 mm x 220 mm

Net : 17 Kg

Gross : 21 Kg

230 V. 50 Hz / 110 V. 50 / 60 Hz

300 VA

Printer interface Epson LX - 310

and only smart verification of leak detection usingŸ

the widely accepted and cost efficient blue dye

method

Compliance with USP and international packageŸ

practice specifications

Leak detection automatically verified by weight,Ÿ

reducing human error and providing traceability to the

results

Programmable vacuum level and retention timeŸ

Slow venting for better precisionŸ

Oil-less vacuum pumpŸ

Printout of test report via serial portŸ

Weighing scale interface with Mettler Toledo, Sartorius,Ÿ

Contech and Ohaus balances

5.7” touch screen displayŸ

Programmable tolerance range setting to calculateŸ

pass/fail results

20 products and 20 methods can be storedŸ

First

Features

ELT - 201W

 t

 

 T e s t  R e p o

 r t

Ideal for checking leakage of packed strips,

blisters, small sachets of tablets , capsules,

liquids, cough syrup, shampoo packets,

ampoules, sutures etc.

Leak Tester

 Methylene Blue Dye Test Method )

Page 4: Catalogue of Leak Test Apparatus

8/20/2019 Catalogue of Leak Test Apparatus

http://slidepdf.com/reader/full/catalogue-of-leak-test-apparatus 4/4

Specifications

Limit of detection : Better than 10 microns hole diameter*

Test cycle time : Down to 10 seconds*  *Performance is a function of pack size

MediTEST M012P-1 : Singular non-destructive pack integrity tester with embedded controller

and multi - line display

Performance

HMI Display : 4 line alpha - numeric displayVoltage : 110 / 230 V, 50 - 60 Hz

Compressed air : 6 bar (2001/ min)

Dimension :  330 (W) x 470 (D) x 450 (H) mm

Weight : 35 Kg

Material : Grade 304 stainless steel casework

Compliance : Can operate in compliance with 21CFR part 11

Standards : CE marked

General

Capacity

Number of packs : Single pack

Pack dimensions : 140 (L) x 125 (W) x 35 (D)* mm  *No minimum. Non-porous packs with head space required

Model

The information contained in this document is believed to be correct but ELECTROLAB accepts no liability for any errors and reserves the right to alter specifications without notice

ELECTROLAB

Sales

&

Service

Worldwide

ELECTROLAB (India) PVT. LTD.

Head Office : 401, Tirupati Udyog, I. B. Patel road, Off. Western Express highway, Goregaon (East), Mumbai - 400 063, India.

Tel : +91 - 22 - 4041 3131 • E-mail : [email protected]

Factory : EL 23/24, T. T. C., Electronic Zone, M. I. D. C, Mahape, Navi Mumbai - 400 710, India.

  Tel : +91 - 22 - 4161 3131 • Website : www.electrolabindia.com

(CIN NO : U33110MH2002PTC136735)

CE

An efficient bench-top non-destructive leak detection systemŸ

Custom designed embedded controllerŸ

User-friendly operations with multi-line alphanumeric displayŸ

Self-adjusting sensor system reduces the requirement for anyŸ

special tool

Front loading for ease of operationŸ

Highly sensitive system enables detection better than 10 micronŸ

hole diameter

Short test cycle time as low as 10 secondsŸ

Capacity to store 10 test methodsŸ

Printer connectivity for printing test reportsŸ

Features

MediTEST (M012P-1)

Applications

Pharmaceutical sachets (powders)Ÿ

Medical test stripsŸ

Medical device packs (non-porous)Ÿ

Modified atmosphere packsŸ

Pillow packsŸ

Flow wrapsŸ

Production and laboratory environmentsŸ

Ideal for testing single sachets, pouches,

flow wraps, sutures and most non-porous

packaging

November, 2014 / 030F00

Non-Destructive

Leak Detection System