catalogue daikin vrv iv s

Upload: hung-tran

Post on 07-Jul-2018

464 views

Category:

Documents


17 download

TRANSCRIPT

  • 8/19/2019 Catalogue Daikin VRV IV S

    1/34

    1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.

    2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install  the outdoor unit close to the sea shore, contact your local distributor.

    Cautions on product corrosion

    Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.

    Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

    Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or

    contractor to install those parts and accessories. Use of unauthorised parts and accessories or

    improper installation of parts and accessories can result in water or refrigerant leakage, electrical

    shock, fire or explosion.

    Read the user's manual carefully before using this product. The user's manual provides important

    safety instructions and warnings. Be sure to follow these instructions and warnings.

    If you have any enquiries, please contact your local importer, distributor and/or retailer.

    For residential and commercial use

    Cooling Only 50 Hz

    PCVMT1522

     

    All rights reservedPrinted in Vietnam 08/15/006 DAV

    S  SERIES 

    - Web: www.savame.com- Email: [email protected] Tel: 08 3512 2727- Hotline: 0978 829 829 (Mr.Hưng)

  • 8/19/2019 Catalogue Daikin VRV IV S

    2/34

    Main Features

    Indoor Unit Lineup

    Specifications

    Option List

    Control Systems

    Air Treatment Equipment Lineup

     

    P03

    P09

    P34

    P47

    P53

    P63

    Contents

    First launched in Japan in 1982, the Daikin VRV  system has been

    embraced by world markets for over 30 years. Now, Daikin proudly

    introduces the new VRV  IV S series-the ideal air conditioning system

    for homes, shops and offices.

    HOMES

    OFFICES

    SHOPS

    Engineered for Flexibility  S SERIES 

    14Max.

    indoorunits VRV  indoor units

    BP unit

    Residential indoor units

    VRV  indoor units combine withresidential indoor units, all in one system.

    01 02

    * VRV is a trademark ofDaikin Industries,Ltd.

  • 8/19/2019 Catalogue Daikin VRV IV S

    3/34

    Main Features

    03 04

    The new design has been optimised for the VRV IV S series, with the height of 4 HP to 5 HP models reduced to only

    990 mm. This design gives the building a sleek look externally and provides the occupants with a clear, unobstructedview of the scenery. The VRV IV S series is now slim and compact, with outdoor units that require minimal installation

    space.

    To suit a variety of room sizes, VRV IV S series expands our range to include 8 HP and 9 HP.

    Compact & lightweight design Enhanced lineup

    Indoor units can be selected from 2 lineups, both VRV  and residential

    indoor units, to match rooms and preferences. A mixed combination of

    VRV  indoor units and residential indoor units can be included into onesystem, opening the door to stylish and quiet indoor units.

    Wide variety of indoor units

    Height

    990 mm26%

    Decrease

    ProductWeight

    71 kg

    43%Decrease

    VRV   S

    VRV   S4,5HP

    ProductWeight

    125 kg

    Height

    1,345 mm

    Height

    1,430 mm14%

    Decrease

    Height

    1,657 mm

    Product Weight

    131 kg29%

    Decrease

    Product Weight

    185 kg

    Footprint

    0.30 m 258%

    Decrease

    Footprint

    0.71 m 2

    4 HP(11.2 kW)   S SERIES 

    S SERIES 

    S SERIES 4, 5 HP

    1,345mm 990

    mm

    320mm320

    mm

    4 HP(11.2 kW)

    Lineup

    Model Name   RXMQ4AVE RXMQ5AVE RXMQ6AVE RXMQ8AY1 RXMQ9AY1

    Power Supply 1-phase, 220- 230 V/220 V, 50/60 Hz 3-phase, 380 – 415 V, 50 Hz

    Capacity Range4 HP

    (11.2 kW)5 HP

    (14.0 kW)6 HP

    (16.0 kW)8 HP

    (22.4 kW)9 HP

    (24.0 kW)

    Capacity Index 100 125 150 200 215

    6 HP

    Mo/C*

    5 HP

    Mo/C*

    4 HP

    Mo/C*

    *Mo/C represents Model Change

    Elegant appearance with

    European styleExternal view of a condominium

    Internal view of acondominium unit

    8 HP 9 HP

    S SERIES 

    5 models

    1,430mm

    320mm

    1,657mm

    940mm

    765mm

    930mm

    8HP

    S SERIES 8 HP

    8 HP(22.4 kW) (22.4 kW)

    8 HP

    FTKJ-N series indoor unit

  • 8/19/2019 Catalogue Daikin VRV IV S

    4/34

    Main Features

    05 06

    Higher Coefficient of Performance (COP)

    VRV  IV S series provides greater energy saving as compared to VRV III S series, especially for 6 HP.

    Nighttime quiet operation function

    Operation sound level selectable from 3 steps for the night mode

    Energy saving

    Collection of cutting-edge technologies realises efficient an d quiet operation

    The high efficiency compressor to achieve a higher COP

    Quiet operationSinewaveDCinverter

    >> Smooth sine wave DC inverterUse of an optimised sine wave smoothes motor rotation, further improving operating efficiency.

    DC fan motor

    Efficiency improved in all areas

    compared to conventional ACmotors, especially at low speeds.

    3

    DC fan motor structure

    These two features work to reduce sound. Guides are added to

    the bell mouth intake to reduce turbulence in the airflow generatedby fan suction. The Aero Spiral Fan features fan blades with the

    bent blade edges, further reducing turbulence.

    Smooth Air Inlet Bell Mouth and Aero Spiral Fan2

    Escaping eddies are sucked in bythe bent blade edges, reducingoverall turbulence.

    With the bent

    blade edge

    Without the bent

    blade edge

    1

    Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products.*1 A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.*2 The torque created by the change in power between the iron and magnet parts.

    Daikin DC inverter models are equipped with the Reluctance DC motor for

    compressor. The Reluctance DC motor uses 2 different types of torque, neodymiummagnet*1 and reluctance torque*2. This motor can save energy because it generates

    more power with a smaller electric power than an AC or conventional DC motor.

    Compressor equipped with Reluctance DC motor

    Reluctance DC motor

    Conventional DCmotor

    ACmotor

    Rotational speed (rps)

        M   o   t   o   r   e    ffi   c    i   e   n   c   y    (    %    )

    ReluctanceDC motor

    3

    1

    2

    90

    80

    70

    60

    500 30 60 90 120

    More than 20%

    More than 20%

    Small load

    Low capacity

    Largeload

    High capacity

    Set on the outdoor PCB. Time of maximum

    temperature is memorised. The low operating modewill initiate 8 hours*1 after the peak temperature in

    the daytime, and normal operation will resume 10

    hours*2 after that. The operation sound level for thenight mode can be selected from 49 dB(A) (Step 1),

    46 dB(A) (Step 2) and 43 dB(A) (Step 3).*3 

    Automatic modeMode 1.

    Starting time and ending time can be input. (An

    external control adaptor for outdoor unit,

    DTA104A53/61/62, and a locally obtained timer arenecessary.)

    Manual modeMode 2.

    Combinations of modes 1 and 2 can be used

    depending on your needs.

    Combined modeMode 3.

    *1. Initial setting. Can be selected from 6, 8 and 10 hours.*2. Initial setting. Can be selected from 8, 9 and 10 hours.*3. In case of 4 HP outdoor unit during cooling operation

    Automatic modeMode 1.

    Note: • This function is available in setting at site.

    • The relationship of outdoor temperature (load) and time shown in thegraph is just an example.

    Peak in outdoor temperature

        C   a   p   a   c    i   t   y    %

    8 hrs 10 hrs

        O   p   e   r   a   t    i   o   n   s   o   u   n    d    d    B    (    A    )

    49

    8:00 12:00 16:00 20:00 0:00 4:00 8:00

    50

    100

    52

    0

        L   o   a    d    %

    Night mode endsNight mode starts

    Night mode endsNight mode starts

    NightMode

    46

    43

    (Initial setting)(Initial setting)

    Step1 max.-3dB(A)

    Step2 max.-6dB(A)

    Step3 max.-9dB(A)

    Step1:49 dB(A)

    Step2:46 dB(A)

    Step3:43 dB(A)

    The capacity reduction rate differs depending on the operation sound level step selected.

    S SERIES 

    VRV   S

    0

    3.2

    3.4

    3.6

    3.8

    4

      6 HP  

    3.80

    3.56

    3.863.77

    3.49

    CoolingOperationCOP

    4 HP(11.2 kW)

    5 HP(14.0 kW) (16.0 kW)

    8 HP(22.4 kW)

    9 HP(24.0 kW)

    3.89 3.863.77

    3.493.56

    12%Increase

    Sucked gas is

    compressed in the

    scrolling part before theheated motor, so that

    the machine compress

    the non-expanded gas,resulting in high efficiency compression.

    >> The structural scroll>> Swing compressor

    Scrollsection

    Suction

    Discharge   Motorsection

    RXMQ 4, 5, 6AVE RXMQ8, 9AY1

    Daikin swing compressor has integrated therotor with the blade, completely solving the

    refrigerant leakage and the wear problem

    caused by the mechanical friction between therotor and the blade, which enhances the

    compressor efficiency and makes the

    compressor more quiet and durable.

    *Cooling operation conditions: Indoor temp. of 27ºCDB,19ºCWB, and outdoor temp. of 35ºCDB.

  • 8/19/2019 Catalogue Daikin VRV IV S

    5/34

    Main Features

    07 08

    Connectable up to 14 indoor units

    As many as 14 indoor units can be connected to a single outdoor unit, making the VRV IV S series a remarkablyversatile system.

    Automatic test operation

    Simply press the test operation button and the unit performs an automatic system check, including wiring, stop valves,

    piping, and refrigerant charging amount. The results are returned automatically after the check finishes.

    Simple wiring and piping connection

    Unique piping and wiring systems make it possible to install a VRV IV S series quickly and easily.

    Design flexibility and simplified installation

    When only VRV indoor units are connected

    Long piping length offers flexibility in the choice of installation positions, and simplifies system planning.

    Long piping design possible

    14 indoorunitsMax.

    BP unit BP unit

    VRV  indoor units

    Residential indoor units

    Daikin’s advanced REFNET piping systemmakes installation easy. Only two main

    refrigerant lines are required in any one

    system. REFNET greatly reduces theimbalances in refrigerant flow between

    units, while using small-diameter piping.

    >> REFNET piping system

    A super wiring system is used to enable

    shared use of the wiring between indoorand outdoor units and the central control

    wiring, with a relatively simple wiring

    operation.The DIII-NET communication system is

    employed to enable the use of advancedcontrol systems.

    >> Super wiring system

    Outdoor unit

    Indoor unit

    Note: Total capacity index of connectable indoor units must be 50-130% of the capacity index of the outdoor unit.

    Refer to page 46 for the maximum number of connectable indoor unit.

    When a mixed combination of VRV and residential indoor units is connected or

    when only residential indoor units are connected

    Max. allowable pipinglength

    Max. & min.allowable pipinglength

    Min.allowablepiping length

    Max. allowable leveldifference Outdoor unit - the indoor

    unit

    BP unit - indoor unit

    Between the indoor units

    Between BP units

    The first indoor branch - the farthest BP or VRV indoor unit

    Total piping length

    Refrigerant piping length

    Outdoor unit - the first indoor branch

    10 m

    10 m

    l

    m

    n

    n

    o

    a+b+c+d+e+f+g+h+i+j+k

    b+c+g, b+c+d

    a+b+c+g+k, a+b+c+d

    h, i, j, k

    a

    50 m

    250 m

    40 m

    2 m–15 m

    2 m–12 m

    2 m–8 m

    5 m

    30 mIf the outdoor unit is above

    If the outdoor unit is below

    If indoor unit capacity index < 60

    If indoor unit capacity index is 60

    If indoor unit capacity index is 71

    30 m

    30 mOutdoor unit - the BP unit

    4HP

    15 m

    15 m

    70 m

    250 m

    40 m

    2 m–15 m

    2 m–12 m

    2 m–8 m

    5 m

    30 m

    30 m

    30 m

    5HP

    15 m

    15 m

    100 m

    250 m

    40 m

    2 m–15 m

    2 m–12 m

    2 m–8 m

    5 m

    50 m

    40 m

    40 m

    6-9HP

    Max. allowable leveldifference

    Max. allowable pipinglength

    Between the outdoor unitand the indoor unit

    Between the indoor units

    Between the first indoor branch and the farthest indoor unit

    Total piping length

    Refrigerant piping length

     j

    a+b+c+d+e+f+g+h+i

    a+b+c+d+i

    b+c+d+i

    50 m

    250 m

    40 m

    4HP

    70 m

    300 m

    40 m

    5HP

    120 m

    300 m

    40 m

    6HP

    100 m

    300 m

    40 m

    8,9HP

    kIf the outdoor unit is above

    If the outdoor unit is below k

    10 m

    30 m

    30 m

    15 m

    30 m

    30 m

    15 m

    50 m

    40 m

    15 m

    50 m

    40 m

    120Max. mActual piping length

    300Max. m Total piping length

    100Max. mActual piping length

    250Max. m Total piping length

    Max.

    50  mMax.

    15  m

    a

    i

     j

    k

    dcb

    hgfe

    First indoor branch

    Max.

    50  m

    Max.

    40  mMax.

    15  m

    Max.

    15  m

    a

    o

    l

    n

    dcb

    gfe

    First indoor branch

    mh i

     j

    k

    BP

    RA RA

    RA

    RA

    VRV

    VRV

    BP

  • 8/19/2019 Catalogue Daikin VRV IV S

    6/34

    09 10

    VRV  indoor units 19 types 99 models 6 types 18 modelsResidential indoor units with connection to BP units

    A mixed combination of VRV  indoor units and residential indoor units can be included intoone system, opening the door to stylish and quiet indoor units.

    Enhanced range of choices

    *Refer to page 46 for the maximum number of connectable indoor units.

    VRV  indoor units

    BP unit

    Residential indoor units

    VRV  indoor units combine with indoor units, all in one system.

    14Max.

    indoorunits

    14Max.

    indoorunits

    25 35

    25 35

    2.5 3.5

    50 60 71

    50 60 71

    5.0 6.0 7.1Rated Capacity (kW)Type Model Name

    Capacity Index

    Slim CeilingMounted Duct

    Wall Mounted

    FDKS-EAVMB

    FDKS-C(A)VMB

    FTKS-DVM

    FTKS-FVM

    (700mmwidthtype)

    (900/1,100mmwidth type)

    FTKJ-NVMW

    FTKJ-NVMS

    FXFQ-SVM

    FXFQ-LUV1

    FXZQ-MVE

    FXUQ-AVEB

    FXCQ-MVE

    FXKQ-MAVE

    FXMQ-PVE

    FXMQ-MAVE

    FXHQ-MAVE

    FXAQ-PVE

    FXLQ-MAVE

    FXNQ-MAVE

    Type Model Name   0 .8 HP 1 H P 1 .2 5H P 1 .6 HP 2 H P 2. 5H P 3 HP 3 . 2H P 4 HP 5 HP 6 HP20 25 32 40 50 63 71 80 100 1 25 140

    8HP 10HP

    20 25 31.25 40 50 62.5 71 80 100 125 140 200 250

    2 00 2 50

    Capacity Range

    Capacity Index

    (700 mmwidth type)

    (900/1,100mmwidthtype)

    FXDQ-PBVE(with drain pump)

    FXDQ-PBVET(without drain pump)

    FXDQ-NBVE(with drain pump)

    FXDQ-NBVET(without drain pump)

    Ceiling MountedCassette(RoundFlow with Sensing)

    Ceiling MountedCassette(Round Flow)

    Ceiling MountedCassette(Compact Multi Flow)

    4-Way FlowCeiling Suspended

    Ceiling MountedCassette(Double Flow)

    Ceiling MountedCassette Corner

    Slim CeilingMounted Duct(Standard Series)

    FXDQ-SPV1Slim CeilingMounted Duct(Compact Series)

    Ceiling MountedDuct

    Ceiling Suspended

    Wall Mounted

    Floor Standing

    ConcealedFloor Standing

    Floor StandingDuct

    FXVQ-NY1

    FTKS-BVMA

    Middle StaticPressure CeilingMounted Duct

    FXSQ-PVE

    VRV indoor units only

  • 8/19/2019 Catalogue Daikin VRV IV S

    7/34

    Indoor Unit Lineup

    11 12

    Presence of people and floortemperature can be detected toprovide comfort and energy savings

    Ceiling Mounted Cassette

    (Round Flow) Type

    4-Way Flow Ceiling

    Suspended Type

    This slim and stylish indoor unitachieves optimum air distribution,and can be installed without theneed for ceiling cavity

    Ceiling Mounted Cassette

    (Double Flow) Type

    Thin, lightweight, and easy to install innarrow ceiling spaces

    Slim Ceiling Mounted Duct Type

    (Standard Series)

    Slim design, quietness andstatic pressure switching

    Ceiling Mounted Cassette

    (Compact Multi Flow) Type

    Quiet, compact, and designed foruser comfort

    Ceiling Mounted CassetteCorner Type

    Slim design for flexible installation

    360 airfl ow improves temperaturedistribution and offers a comfortableliving environment.

    Ceiling Mounted Cassette

    (Round Flow with Sensing) Type

    FXFQ-SVM FXFQ-LUV1

    FXZQ-MVE

    FXUQ-AVEB

    FXCQ-MVE

    FXKQ-MAVE   FXDQ-PBVE(T)

    FXDQ-NBVE(T)

    Slim Ceiling Mounted Duct Type

    (Compact Series)

    Slim and compact design for easy andflexible installation

    FXDQ-SPV1

    Ceiling Suspended Type

    Slim body with quiet and wide airflow

    FXHQ-MAVE

    Slim Ceiling MountedDuct Type

    Slim and smooth design suitsyour shallow ceiling

    FDKS-EAVMB

    FDKS-C(A)VMB

    Elegant appearance withEuropean style

    Wall Mounted Type

    Wall Mounted Type

    Stylish flat panel harmoniseswith your interior décor

    FTKJ-NVMW

    FTKJ-NVMS

    FTKS-DVM

    FTKS-BVMA

    FTKS-FVM

    Ceiling Mounted Duct Type

    High external static pressureallows flexible installations

    FXMQ-PVE

    FXMQ-MAVE

    Wall Mounted Type

    Stylish flat panel designharmonised with your interiordécor

    FXAQ-PVE

    Floor Standing Duct Type

    Large airfiow type for large spaces.Flexible interior design for each tenant.

    FXVQ-NY1

    Floor Standing Type

    Concealed Floor Standing Type

    Suitable for perimeter zone airconditioning

    FXLQ-MAVE

    FXNQ-MAVE

    VRV  indoor units

    Residential indoor units with connection to BP units

    Daikin offers a wide range of indoor units includes both VRV  and residential models responding to variety of needs of

    our customers that require air-conditioning solutions.

    Middle Static Pressure CeilingMounted Duct Type

    FXSQ-PVE

    Middle external static pressureand slim design allow flexible installationsMiddle external static pressureand slim design allow flexible installations

  • 8/19/2019 Catalogue Daikin VRV IV S

    8/34

    Indoor Unit Lineup

    13 14

    VRV Indoor Units

    Ceiling Mounted Cassette (Round Flow with Sensing) Type

    FXFQ25S / FXFQ32S / FXFQ40S

    FXFQ50S / FXFQ63S / FXFQ80SFXFQ100S / FXFQ125S

    Presence of people and floor temperature can be

    detected to provide comfort and energy savings

    Thanks to the individual airflow direction controlfunction, airflow direction can be individually adjustedfor each air discharge outlet to prevent uncomfortabledrafts and to deliver optimal air distribution.

    The sensor detects human presence and adjusts theairflow direction automatically to prevent drafts.

    The sensor detects the floor temperature and automaticallyadjusts operation of the indoor unit to reduce thetemperature difference between the ceiling and the floor.

    Infrared presence sensor

    Infrared floor sensor

    Ceiling height

    Detection range (diameter)

    2.7mapprox.

    11m

    3.5mapprox.

    14m

    4.0mapprox.

    16m

    *2. The infrared floor sensor detects at the floor surface.

    *1. The infrared presence sensor detects 80 cm above the floor.

    *2

    Ceiling height

    Detection range (diameter)

    2.7mapprox.8.5m

    3.5mapprox.11.5m

    4.0mapprox.13.5m

    *1

    Individual airflow direction control

    Sensing function

    A

    D

    C

    B

    Dead spot of airflow

    With the Auto airflow direction mode, flaps arecontrolled to deliver optimal air distribution for both coolingand heating operations when there are no people.

    Indoor unit offers 360° airflow discharges air in alldirections with more uniform temperature distribution.

    When a person is detected, drafts are prevented bymaking the flap horizontal.

    When a person is not detected for 5 minutes,the unit automatically returns to controlling theflaps for an unoccupied room.

    Swing Swing Blown horizontally

    Selectable airflow rate: 3 steps and Auto.(Auto airflow rate is available when BRC1E62 is used.)

    Improved energy efficiency thanks to a new heatexchanger with smaller tubes, DC fan motor, and DC drainpump motor.

    Drain pump is equippedas standard accessorywith 850 mm lift.

    Low operation sound level

    45/40/35

    125

    44/38/32

    100

    38/35/31

    80

    38/33/28

    63

    36/32/28

    50

    31/29/27

    4025/32

    30/28.5/27Sound level

    (H/M/L)

    FXFQ-S

    850 mm

    Detecting thepresence ofpeople in 4 areas

    Draft prevention function (default: OFF) *1. 2

    Cooling Dry

    Detecting the averagetemperature of indoor floor

    Auto airflow direction mode

    *1.Airflow direction shoud be set to Auto. *2.Draft prevention function is OFF in the initial setting. It can be set ON using the remote controller.

    When there is a large difference between the ceiling and floor temperatures, the airflow rate is automatically increased.When the difference becomes small, the airflow rate is automatically reduced.

    *1.Both airflow direction and airflow rate shoud be set to Auto. *2.Draft prevention function is set OFF in the initial setting.

    Comfort and Energy saving preventing over Cooling  *1. 2

    Floor temperature is detected and over cooling prevented.

    To increase comfort, Auto airflow rate mode controls the airflow in accordance withthe difference between floor and ceiling temperatures.

    The temperature near the person is automatically calculated by detecting the temperature of the floor. Energy issaved, because the area around the feet does not get too cold.

    Auto airflow direction mode +Auto airflow rate mode

    Without sensing function With sensing function

    30°C near ceiling

    20°C near floor

    Roomtemperature is

    detected as30°C.

    Area around feet gets too cold because air conditionercontinues until the temperature near the ceiling reaches theset temperature.

    Room temperature iscalculated as 27°C in the area which

    is in the vicinity of the person.

    24°C near floor

    30°C near ceiling

     The floor temperature,which is lower than nearthe ceiling, is detected.

    Energysavings

    Automatic control using thetemperature near the personas the room temperature.

    Cooling

    When human presence not detected. When human presence detected.

  • 8/19/2019 Catalogue Daikin VRV IV S

    9/3415 16

    Indoor Unit LineupVRV Indoor Units

    If people do not return, the

    air conditioner will raise the

    temperature 1� every 30

    minutes and then operate

    at 30�.

    The system automatically saves energy by

    detecting whether or not the room is occupied. The

    set temperature is shifted automatically if the room

    is unoccupied.

    The system automatically saves energy by detecting whether or

    not the room is occupied.

    Based on preset user conditions, the system automatically stops

    operation if the room is unoccupied.

    Example• Cooling setpoint: 26� • Shift temperature: 1.0� • Shift time:30 min.  • Limit cooling temperature:30�

    Airf low block function prevents uncomfortable drafts by reducing air veloci ty toapprox. 0.3m/s.*2

    The system automatically saves energy by detecting

    whether or not the room is occupied. The set temperature

    is shifted automatically if the room is unoccupied.

    Airflow block function prevents uncomfortable drafts by

    reducing air velocity.

    It can be set using the BRC1E62 remote controller. There is

    no need for sealing material of air discharge outlet (option).

    This function only works when all-round flow is used. It cannot

    be used when sealing material is used in the air discharge

    outlet (option).

    *1.These functions are not available when using the group control system.*2.User can set these functions with remote controller.*3.Please note that upon re-entering the room, air conditioner will not switch on automatically.

    *1. Works in one direction only.*2. In case of FXFQ63S type (Data is based on Daikin research.) When using FXFQ80S type or higher, if the airflow rate is set to High, airflow will be on the high side.

    Under actual conditions, however, the airflow value may differ depending on the effect of surrounding conditions and the way in which the temperature was adjusted.*3. A gap of 1500 mm is required if the  air block function is not used.

    Individual airflow setting

    Airflow direction of each of the four air outlets can be controlled individually.(Positions 0 to 4, Swing, Blocked, and No individual setting are selectable.)

    Airflow block function*1

    Total comfort by individual airflow direction control and “airflow block function”

    Sensing sensor low mode (default: OFF)

    When there are no people in a room,

    the set temperature is shifted automatically.  

    Sensing sensor stop mode (default: OFF)

    When there are no people in a room, the system stops automatically.* 3

    Horizontal flow Airflow block  

    Easy setup with remote controller

    Sensing sensor mode**

    Individual airflow direction controlCeiling Mounted Cassette (Round Flow with Sensing) Type

    Operation is reduced in placeswhere there are no people.

    2827

    26

    Occupied

    Unoccupied

    Automaticallyreverts whenpeople return.

    27� 28�

    26�26� 26�26�

    27� 28�

       S  e   t  p  o   i  n   t   (   �   )

    TimeAfter 30 min After another 30 min

    Absent stop time can be selected from 1 to 24 hrs in 1 hr incrementswith remote controller.

    Shift temperature and time can be selected from 0.5 to 4� in 0.5� increments and 15, 30, 45, 60, 90 or 120 minutesrespectively with remote controller.

    Airflow blockair velocityapprox. 0.3m/s*1

    500mm

    Wall

    Airflowblock 

    *3

    Also can supportsuch case

    Airflow blockfor cabinet side

    The airflow block functionis useful when rearrangingthe room layout.

    1

    2

    3

    4 Outlet mark

    1 Blocked

    3 Position 24 Swing

    2No individualsetting(Auto direction)

    Example

    Swing Position 2

    blocked

    No ind. set

    A

  • 8/19/2019 Catalogue Daikin VRV IV S

    10/34

  • 8/19/2019 Catalogue Daikin VRV IV S

    11/3419 20

     Thin, lightweight, and easy to install in

    narrow ceiling spaces

    305 mm

    The thin unit (only 305 mm high) can be installed in a

    ceiling space as narrow as 350 mm. All models feature a

    compact design with a depth of only 600 mm.

    (When a high-efficiency filter is attached, the unit's height is

    400 mm.)

    Designed with higher airflow suitable for high ceiling

    application up to 3 metres.

    Providing 2 different settings of standard and ceiling soiling

    prevention, the auto swing mechanism realises even

    distribution of airflow and room temperature.

    Two types of optional high-efficiency filter are available

    (65% and 95%, colourimetric method).

    A long-life filter (maintenance free up to one year*) is

    equipped as standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

    Major maintenance work can be performed by removing

    the panel. A flat-type suction grille and a detachable

    blade make cleaning easy.

    FXCQ20M / FXCQ25M / FXCQ32M

    FXCQ40M / FXCQ50M / FXCQ63M

    FXCQ80M / FXCQ125M

    Drain pump is equipped as standard accessory with

    600 mm lift.

    600 mm

    (220 V)(dB(A))Low operation sound level

    FXCQ-M 20

    32/27

    25/32

    34/28

    63

    37/32

    40/50

    34/29

    80

    39/34

    125

    44/38Sound level

    (H/L)

    Ceiling Mounted Cassette (Double Flow) Type

    Indoor Unit LineupVRV Indoor Units

    Ceiling Mounted Cassette Corner Type

    Slim design for flexible installation

    Main body

    Air discharge grille(Option)

    Set for front discharge using a suspended ceiling.

    Downward discharge is shut off and air is blown straight out(front discharge).

    Front discharge is possible with an air discharge

    unit (option), which allows the installation in the

    drop-ceiling or sagging wall.

    Single-flow type allows effective air discharge

    from corner or from drop-ceiling.

    Providing 3 different settings of standard, draft

    prevention and ceiling soiling prevention, the

    auto swing mechanism realises even distribution

    of airflow and room temperature.

    Main body

    Downward discharge

    Air discharge grille (Option)

    3

    32˚C   30˚C

    28 C̊ 26 C̊24˚C

    22˚C

    20˚C

    2

    1

    0 1 2 3 4 5 6 (m)

    (m)

    500 mm

    Drain pump is equipped as standard

    accessory with 500 mm lift.

    Panel spacer

    20 mm

    Min.195 mm

    Slim body needs only 220 mm space above the

    ceiling. If you use a panel spacer (option), the

    unit can be installed in the minimum space of

    195 mm.

    A long-life filter (maintenance free up to one

    year*) is equipped as standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m 3

    FXKQ25MA / FXKQ32MA

    FXKQ40MA / FXKQ63MA

  • 8/19/2019 Catalogue Daikin VRV IV S

    12/3421 22

    Slim design, quietness and

    static pressure switching

    Only 200 mm in height, this model can be installed in

    rooms with as little as 240 mm in height for the ceiling

    space between the drop-ceiling and ceiling slab.

    Only 700 mm in width and 23 kg in weight, this

    model is suitable to install in limited spaces like

    drop-ceilings in hotels.

    * The values of operation sound level represent those for rear-suction operation.

    Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).* Values are based on the following conditions:

    FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure

    of 15 Pa.

    * 1,100 mm in width for the FXDQ63NB model.

    200 mm900  mm

    Suction grille *AIR

    AIR

    Discharge grille *

    Air filterSuspension bolt*

    240  mm

    * To be obtained locally

    Only  700  mm200  mm

    Great for

      hotel use!

    Suited to use in drop-ceilings!

    Control of the airflow rate has been improved from 2-step

    to 3-step control.

    FXDQ20PB / FXDQ25PB / FXDQ32PB FXDQ40NB / FXDQ50NB / FXDQ63NB

    Low operation sound level (dB (A))

    External static pressure selectable by remote controllerswitching make this indoor unit a very comfortable andflexible model.

    10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models.15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.

    FXDQ-PB and FXDQ-NB models are available in twotypes to suit different installation conditions.

    FXDQ-PB/NBVE: with a drain pump (750 mm lift)as a standard accessory

    FXDQ-PB/NBVET: without a drain pump

    Slim Ceiling Mounted Duct Type (Standard Series)

    33/31/29

    6363

    33/30/27

    50

    30/28/26

    40

    28/26/23

    20/25

    Sound level(HH/H/L)

    FXDQ-PB/NB

    28/26/24

    32

    Indoor Unit LineupVRV Indoor Units

    750 mm

    Ceiling

    FXDQ20SP / FXDQ25SP

    FXDQ32SP / FXDQ40SPFXDQ50SP / FXDQ63SP

    Slim and compact design for easy and flexible installation

    It is available in two types – ceiling r eturn and ordinary

    duct to suit different installation conditions.

    Duct

    Air

    discharge

    Air suction

    Duct

    Canvas bellowsand air suctionpanel

    Air

    discharge

    Air suction

    750 mm

    Ceiling

    Drain pump is equipped

    as standard accessory

    with 750 mm lift.

    200 mm

    Only  450 mm

    Slim Ceiling Mounted Duct Type (Compact Series)

    It comes with a slim and compact design with a height

    of only 200 mm that requires as little as 240 mm in

    height for the ceiling space between the drop- ceiling

    and ceiling slab. The depth of the product is only 450

    mm which is suitable to install in limited spaces.

    700 mm**For FXDQ20-32SP models

    Side view  Top view

    240 mmandabove

    Ceiling

       2   0   0      m

         m

    Great for

    residential use

  • 8/19/2019 Catalogue Daikin VRV IV S

    13/3423 24

    Indoor Unit LineupVRV Indoor Units

    Middle external static pressure

    and slim design allow flexible installations

    Middle Static Pressure Ceiling Mounted Duct Type Indoor Unit

    FXSQ20P / FXSQ25P / FXSQ32P

    FXSQ40P / FXSQ50P / FXSQ63P

    FXSQ80P / FXSQ100PFXSQ125P / FXSQ140P

    Installation flexibility

    Design flexibility

    Comfort

    Easy maintenance

    Easy installation

    850

    Ceiling

    With a height of only 245 mm, installation is possible

    even in buildings with narrow ceiling spaces.

     DCdrain pump is

    equipped as standard

    accessory with850 mm lift.

     Air suction direction can be altered from rear tobottom suction.

     Bottom suction is possible which facilitates installation

    and maintenance. Wiring connections and

    maintenance of control box can be done from underthe unit with an optional shield plate for side plate*,

    extending the degree of freedom for installation in the

    ceiling.

    Air suction

    JoistAir conditioner

    ceiling

    Switch bottom platewith air suction flange.

    Rear suction

    Bottom suction

    Shield plate for side plate* (Option)

    Ceiling

       2   4   5       

          

    245

    *An optional shield plate for side plate is required if wiring connections andmaintenance of control box are needed from under the unit. This option is onlyavailable for FXSQ20-125P models.

    Slim design

    Standard DC drain pump

    Bottom suction possible

    Using a DC fan motor, the external static pressure can

    be controlled within a range of 30 Pa* to 150 Pa.

    *30 Pa–150 Pa for FXSQ20-40PVE 50 Pa–150 Pa for FXSQ50-125PVE

     50 Pa–140 Pa for FXSQ140PVE

    Comfortable airflow is achieved in accordance with

    conditions such as duct length.

    Adjustable external static pressure

    30 Pa* 150 Pa

    Set to high static pressure for

    advanced needs such as when

    using dampers and long ducts.

    Set to low static

    pressure when ducts

    are short.

    Adjustable external static pressure

    Control of the airflow rate can be selected from 3-step

    control.

    (dB(A))

    36/32/29

    63

    34/32/29

    50

    36/33/30

    40

    34/32/30

    32

    33/30/28

    20/25

    Sound level(H/M/L)

    FXSQ-PVE

    43/40/36

    140

    42/38.5/35

    125

    39/35/32

    100

    37.5/34/30

    80

    Sound level(H/M/L)

    FXSQ-PVE

    5-step airflow rate is automatically controlled in

    accordance with the difference between room

    temperature and set temperature.Auto airflow rate control can be selected with wired

    remote controller BRC1E62.

    Switchable airflow rate

    Auto airflow rate

    Low operation sound level

     Inspection and cleaning is facilitated by separating the

    drain pipe and inspection opening and by thedrain pan maintenance check hole.

    Drain pan maintenance check hole

    Separate drain pipeand inspection opening

      The drain pan can be detached for easy cleaning.

    An antibacterial treatment that uses silver ions has been

    applied to the drain pan, preventing the growth of slime,mould and bacteria that cause blockages and odours.

     During installation, even if the external static pressure

     changes due to a change in the duct route, the airflow

     can be automatically adjusted to within the unit’s external static pressure range.

     Airflow rate can be controlled using a remote

    controller during test operation. It is automatically

    adjusted to the range between approximately ±10% of the rated H tap airflow.

    Airflow rate auto adjustment function

  • 8/19/2019 Catalogue Daikin VRV IV S

    14/3425 26

    Indoor Unit LineupVRV Indoor Units

    Middle and high static pressure

    allows for flexible duct design

    Built-in Drain Pump (Option)Housing the drain pump inside the unit reduces thespace required for installation.

    All models are only 300 mm in height, an improvementover the 390 mm height of conventional models. Theweight of the FXMQ40P has been reduced from 44 kgto 28 kg.

    A DC fan motor increases the external static pressurecapacity range to include middle to high staticpressures, increasing design flexibility.

    Indoor unit

    470 mm

    Indoor unit

    470 mm

    0–250mm

    222 mm

    Without drain pump With drain pump

    Simplified Static Pressure ControlExternal static pressure can be easily adjusted using achange-over switch inside the electrical box to meet theresistance in the duct system.

    FXMQ200MA/FXMQ250MA

    Drain pump is equipped asstandard accessory with700 mm lift.

    Control of the airflow rate has been improved from

    2-step to 3-step control.

    (dB (A))

    46/45/43

    140

    42/40/38

    63

    43/41/39

    80/100

    41/39/37

    50

    39/37/35

    40

    34/32/30

    32

    33/31/29

    20/25

    Soundlevel

    (HH/H/L)

    FXMQ-P

    700 mm

    Ceiling

    30 Pa–100 Pa for FXMQ20P-32P30 Pa–160 Pa for FXMQ40P50 Pa–200 Pa for FXMQ50P-125P50 Pa–140 Pa for FXMQ140P

    Low operation sound level

    Improved ease of installation

    Improved ease of maintenance

    Airflow rate can be controlled using a remote controller

    during test operation. With the conventional model, the

    airflow rate was controlled from the PC board. It is

    automatically adjusted to the range between approximately

    ±10% of the rated HH tap airflow for FXMQ20P–125P.

    The drain pan can be detached for easy cleaning. An

    antibacterial treatment that uses silver ions has been

    applied to the drain pan, preventing the growth of slime,

    mould and bacteria that cause blockages and odours.

    Energy-efficient

    The adopted DC fan motor is much more efficient than

    the conventional AC motor, yielding an approximate

    20% decrease in energy consumption (FXMQ125P).

    25 mm

    44/42/40

    125

    FXMQ20P / FXMQ25P / FXMQ32P

    FXMQ40P / FXMQ50P / FXMQ63P

    FXMQ80P / FXMQ100P / FXMQ125P

    FXMQ140P

    Ceiling Mounted Duct Type

     This slim and stylish indoor unit achieves

    optimum air distribution, and can be installed

    without the need for ceiling cavity.

    Unit body and suction panel

    adopted round shapes andrealised a slim appearancedesign. The unit can be used

    for various locations such asthe ceilings with no cavity andbare ceilings.

    Flaps close automatically whenthe unit stops, which gives asimple appearance.

    Unified slim height of 198 mmfor all models that gives the

    unified impression even whenmodels with different capacitiesare installed in the same area.

    Built-in electronic expansion valve eliminates the needfor a BEV unit, which improves flexibility of installation.

    With adoption of the individual flap control, airflowdirection adjustment can be individually set for each airoutlet. 5 directions of airflow and auto-swing can be

    selected with wired remote controller BRC1E62, whichrealises the optimum air distribution.

    Control of the airflow rate has been improved from2-step to 3-step control. Auto airflow rate control canbe selected with wired remote controller BRC1E62.

    Energy efficiency has been improved thanks to theadoption of a new heat exchanger with smallertubes, DC fan motor and DC drain pump motor.

    Drain pump is equipped as a standard accessory, and thelift height has been improved from 500 mm to 600 mm.

    Depending on installation site requirements or roomconditions, 2-way, 3-way and 4-way dischargepatterns are available.

    4-way flow 3-way flow

    L-shaped 2-way flow

    198 mm

    BEV unitisnotneeded

    BEV unit isneeded

    Current model New model

    Position 0 Position 2

    Position 3 Swing

    Individual airflow direction example case

    FXUQ71A / FXUQ100A

     4-Way Flow Ceiling Suspended Type

  • 8/19/2019 Catalogue Daikin VRV IV S

    15/3427 28

    Indoor Unit LineupVRV Indoor Units

    Stylish flat panel design harmonised

    with your interior décor

    Drain pan and air filter can be kept clean by mould-proof

    polystyrene.

    Vertical auto-swing realises efficiency of air distribution.

    The louvre closes automatically when the unit stops.

    5 steps of discharge angle can be set by remote

    controller.

    Discharge angle is automatically set at the same angle

    as the previous operation when restarting. (Initial setting:10° for cooling and 70° for heating)

    Flexible installation

    Drain pipe can be fitted to from either left or

    right sides.

    Stylish flat panel design creates a graceful harmony that

    enhances any interior space.

    Flat panel can be cleaned with only the single pass of a

    cloth across their smooth surface.

    Flat panel can also be easily removed and washed for

    more thorough cleaning.

    Drain pump kit is available as optional accessory, which

    lifts the drain 1,000 mm from the bottom of the unit.

    Drain pump kit

    1,000 mm

    Height of drain-up

    Indoor unit

    FXAQ20P / FXAQ25P

    FXAQ32P / FXAQ40PFXAQ50P / FXAQ63P

    Low operation sound level(dB(A))

    47/4147/41

    6363

    42/3742/37

    5050

    39/3439/34

    4040

    38/3138/31

    3232

    36/3136/31

    2525

    35/3135/31

    2020

    Sound level(H/L)

    Sound level(H/L)

    FXAQ-PFXAQ-P

    Wall Mounted TypeCeiling Suspended Type

    Slim body with quiet and wide airflow

    Adoption of QUIET STREAM FAN

    Drain pump kit (option) can be easily incorporated.

    Easy-to-clean flat design

    Maintenance is easier because everything can be

    performed from below the unit.

    Non-dew Flap with no implanted bristles

    Uses the quiet stream fan and manymore advanced technologies.

    Sound absorptionmember

    Turbulent flow is produced

    Straightening vane

    Quiet stream fan

    Installation is easy

    Maintenance is easy

    Drain pump kit

    (built inside main unit)

    600  mm

    Bristle-free Flap minimisescontamination and makescleaning simpler.

    Non-dew Flap

    100°

    Wide air discharge openings produce a spreading 100°

    airflow.

    A long-life filter (maintenance free up to one year*) is

    equipped as standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m 3

    FXHQ32MA / FXHQ63MA

    FXHQ100MA

    FXHQ-MA

    Sound level(H/L)

    Sound level(H/L)

    3232

    36/3136/31

    6363

    39/3439/34

    100100

    45/3745/37

    (dB(A))Low operation sound level

  • 8/19/2019 Catalogue Daikin VRV IV S

    16/3429 30

    Floor Standing Duct Type

    FXVQ125N / FXVQ200N

    FXVQ250N

    Large airflow type for large spaces.Flexible interior design for each tenant.

    Large airflow type that fits for spacious areas such as factoriesand large stores.

    Various installations can be supported from full-scale ductconnection airflow to direct airflow that allows for easyinstallation.

    Outdoor air intake mode isuseable as an outdoor-airprocessing air conditioner.

    *When using the unit as an outdoor-airprocessing unit, there are somerestrictions. Strictly follow the restrictionsspecified in the Engineering Data Book.

    All-fresh (using outdoor air only) system Return + Outdoor air mixed system

    OutsideAirconditioning

    Outdoor airintroduction

    Air

    conditioning

     C i   r  c  ul    a  t   e  d   a i   r 

    Outdoor airintroduction

    Outside

    * Air introduced from the outside and circulated air must be mixed in theair conditioner primary side before introduction into the air conditioner.

    Adding the plenum chamber (option)allows for simple operation with directairflow.

    * Note that the operation sound increases by

    approximately 5 dB(A).

    Direct airflow type

    Full-scale duct connection airflowallows for air conditioning evenly inspacious areas.

    Duct connection airflow type

    The high static pressure type driven by the belt drivesystem allows for use of air discharge outlets in variousshapes as well as long ducts. Highly flexible installationis possible.

    Design with high maintainability that allows majorservices and maintenance services to be performed atthe front.

    A long-life filter (maintenance free up to one year*) isequipped as a standard accessory.

    * 8 hr/day, 26 day/month. For dust concentration of 0.15 mg/m 3

    A wide range of optional accessories are available suchas high-efficiency filters.

    Floor Standing Type

    Concealed Floor Standing Type

    Suitable for perimeter zone air conditioning

    Wall hanging Floor installation

    Floor Standing types can be hung on the wall for easier

    cleaning. Running the piping from the back allows the unit

    to be hung on walls. Cleaning under the unit, where dust

    tends to accumulate, is considerably easier.

    A long-life filter (maintenance free up to one year*) is

    equipped as standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m

    3

    The adoption of a fibre-less discharge grille featuring an

    original design to prevent condensation also helps prevent

    staining and makes cleaning easier.

    Designed to be concealed in the perimeter skirting-wall

    Connectingport

    Refrigerantpiping

    *Appliesalsoto FloorStandingtype(FXLQ-MA).

    The unit is concealed in skirting-wall of perimeter, that

    enables to create high class interior design.

    The connecting port faces downward,

    greatly facilitating on-site piping work.

    A long-life filter (maintenance free up to

    one year*) is equipped as standard

    accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m 3

    FXNQ20MA / FXNQ25MA

    FXNQ32MA / FXNQ40MA

    FXNQ50MA / FXNQ63MA

    FXLQ20MA / FXLQ25MA

    FXLQ32MA / FXLQ40MA

    FXLQ50MA / FXLQ63MA

    Indoor Unit LineupVRV Indoor Units

  • 8/19/2019 Catalogue Daikin VRV IV S

    17/3431 32

    Indoor Unit LineupResidential Indoor Units with connection to BP units

    Wall Mounted Type

    3D Airflow3D Airflow combines Vertical and Horizontal Auto-Swing

    to reduce indoor temperature fluctuation. This function

    circulates air to every part of a room for uniform cooling

    or heating of even large spaces. To start 3D Airflow,

    push both the Vertical and Horizontal Auto-Swingbuttons. The flaps and louvers swing in turn.

    Two-Area Intelligent EyeA combination of Comfort Airflow Mode and Intelligent

    Eye directs airflow away from people to avoid drafts. Ifthere is no movement in a room for 20 minutes,

    Intelligent Eye automatically adjusts the set

    temperature by approximately 2°C to save energy.

    Area 2Area 1

    If a person is detected in area 1, airflow is

    directed away from him/her.

    Area 2Area 1

    If a person is detected in area 2, airflow isdirected away from him/her.

    Elegant Appearance with Curved Panel

    The sleek design of the FTKJ-N indoor unit featuresa uniquely European style. This elegant body

    houses state-of-the-art technology which delivers

    superior performance. The FTKJ-N series offers a

    versatile choice for home-owners, designers and

    architects alike.

    Comfort Airflow Mode

    Comfort Airflow Mode prevents uncomfortable draftsfrom blowing directly on to a person’s body. During

    cooling operation, the flap moves upwards to prevent

    cold drafts. During heating operation, the flap turns

    vertically downwards to drive warm air to the floor.

    The flaps and louvers swing in turn,expanding the comfort zone.

    FTKJ25N / FTKJ35N / FTKJ50N

    Standardaccessory

    Elegant appearance with European styleSlim and smooth design suits your shallow ceiling

    Signals from the wireless remote controller aretransmitted to the signal receiver.

    240 mm

    Home Leave Operation prevents large rises or falls in

    the indoor temperature by continuing operation* while

    you are sleeping or out of your home. This means that

    an air-conditioned welcome awaits when you wake or

    return. It also means that the indoor temperature can

    quickly return to your favourite comfort setting.

    Notes:1. To prevent an increase in operation noise, avoid installing the air suction grille

    directly below the suction chamber.2. Grilles, piping connections, ducts, and installation parts should be obtained

    locally. Slim Ceiling Mounted Duct type models do not have drain-up pumps.3. The signal receiver unit must be located near the air suction inlet, because the

    unit includes a sensor that detects room temperature.

    * Locally obtained partsAIR

    Air suctiongrille*

    Suction duct*

    Signalreceiver

    Air discharge duct* Suspension bolt*

    Air discharge grille*

    Signal receiver wireLength = 1,900 mm

    Chamber

    AIR

    Air filter

    * Home Leave Operation can be selected for any temperature from 18 to32˚C for cooling operation and 10 to 30˚C for heating operation.

    * Home Leave Operation function must be set using the remote controllerwhen going to sleep or leaving the house, and after waking up or returninghome.

    Slim Ceiling Mounted Duct Type

    Standard accessoryNote: Remote controllersother than the standardaccessory wireless remotecontroller cannot be used.

    700 mm width type

    900/1,1000 mm width typeFDKS25EA / FDKS35EA

    FDKS25CA / FDKS35CAFDKS50C / FDKS60C

    200 mm

    Only 700 mm

    FDKS-EA

    Dimensions (H x W x D)

    Weight

     Airflow rate (H)

    External static pressure

    200 x 700 x 620 mm

    21 kg

    8.7 m3 /min

    30 Pa

    200 x 900 x 620 mm

    25 kg

    40 Pa

    FDKS25EA FDKS35EA FDKS25CA   FDKS35CA

    9.5 m3 /min 10 m3 /min

    Models in the FDKS-EA series are only 700 mm

    in width and 21 kg in weight, so are easilyinstalled in limited spaces. Just 200 mm in height,

    all models can be installed in rooms with as little

    as 240 mm depth between the drop ceiling and

    ceiling slab, making them ideal for even shallow

    ceilings.

    Great for

      hotel use!

    FDKS25

    35/31/ 29 dB (A)

    FDKS35

    35/31/ 29 dB (A)

    FDKS50

    37/33/ 31 dB (A)

    FDKS60

    38/34/ 32 dB (A)

    (H/L/ SL)Low operation sound level

    Note: Remote controllers other than the standard accessory wireless remote controller cannot be used.

  • 8/19/2019 Catalogue Daikin VRV IV S

    18/34

    SpecificationsIndoor Unit LineupResidential Indoor Units with connection to BP units

    33 34

    VRV  Indoor Units

    Note: Specifications are based on the following conditions;•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.(See Engineering Data Book for details.)

    •Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    Ceiling Mounted Cassette (Round Flow with Sensing) Type

    Fresh white

    50×950×950

    5.5

    19

    246×840×840

    Galvanised steel plate

    1-phase, 220-240 V/220-230 V, 50/60 Hz

    441/406/353

    30/28.5/27

    12.5/11.5/10.0

    0.031

    2.8

    9,600

    2,400

    FXFQ25SVM

    441/406/353

    30/28.5/27

    12.5/11.5/10.0

    0.031

    3.6

    12,300

    3,100

    FXFQ32SVM

    512/459/388

    31/29/27

    14.5/13.0/11.0

    0.041

    4.5

    15,400

    3,900

    FXFQ40SVM

    23

    777/618/477

    36/32/28

    22.0/17.5/13.5

    0.080

    5.6

    19,100

    4,800

    FXFQ50SVM

    BYCQ125B-W1

    6.4

    12.7

    VP25 (External Dia, 32/Internal Dia, 25)

    cfm

    dB(A)

    mm

    kg

    mm

    mm

    kg

    kcal/h

    Btu/h

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Model

    Colour

    Dimensions(H×W×D)

    Weight

    Power consumption

    Casing

    Sound level (H/M/L)

    Airflow rate (H/M/L)

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Panel(Option)

    Power supply

    Cooling capacity

    MODEL

    Cooling

    Fresh white

    50×950×950

    5.5

    246×840×840 288×840×840

    Galvanised steel plate

    1-phase, 220-240 V/220-230 V, 50/60 Hz

    23

    BYCQ125B-W1

    VP25 (External Dia, 32/Internal Dia, 25)

    15.9

    9.5

    7.1

    24,200

    6,100

    FXFQ63SVM

    830/653/477

    38/33/28

    23.5/18.5/13.5

    0.095

    11.2

    38,200

    9,600

    FXFQ100SVM

    1,165/918/671

    44/38/32

    33.0/26.0/19.0

    0.194

    9.0

    30,700

    7,700

    FXFQ80SVM

    830/688/530

    38/35/31

    23.5/19.5/15.0

    0.095

    14.0

    47,800

    12,000

    FXFQ125SVM

    1,218/971/741

    45/40/35

    34.5/27.5/21.0

    0.219

    26

    cfm

    dB(A)

    mm

    kg

    mm

    mm

    kg

    kcal/h

    Btu/h

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Model

    Colour

    Dimensions(H×W×D)

    Weight

    Power consumption

    Casing

    Sound level (H/M/L)

    Airflow rate (H/M/L)

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Panel(Option)

    Power supply

    Cooling capacity

    MODEL

    Cooling

     

    Wall Mounted Type

    Intelligent Eye with its infrared sensor

    automatically controls air conditioner operation

    according to human movement in a room. When

    there is no movement, it adjusts the temperature

    by 2˚C for energy savings.

    3-D Airflow

    combines Vertical

    and Horizontal

    Auto-Swing to

    circulate air to every

    part of a room for

    uniform cooling of even

    large spaces.* This function is available for

    FTKS50/60/71F.

    FTKS25D

    37/25/ 22 dB (A)

    FTKS35D

    39/26/ 23 dB (A)

    FTKS50F

    43/34/ 31 dB (A)

    FTKS60F

    45/36/ 33 dB (A)

    FTKS71F

    46/37/ 34 dB (A)

    (H/L/ SL)

    Wh en yo u ar e i n t he r oo m Wh en yo u g o o ut

    A uniform temperatureis achieved throughoutthe entire room.

    Stylish flat panel harmonises with your interior décor

    * Remote controllers other than the standard accessory wireless remote controller cannot be used.

    Standard accessory*

    Standard accessory*

    Standard accessory*

    FTKS25D / FTKS35D

    FTKS50B

    FTKS50F / FTKS60F / FTKS71F

    Wall Mounted indoor units achieve quiet sound

    levels of 22 dB (A).

    Titanium apatite is a photocatalytic material with

    high adsorption power. Titanium apatite also

    effectively adsorbs and decomposes bacteria

    across its entire surface. The photocatalyst is

    activated simply by exposure to light.

    These filters are not medical devices. Benefits

    such as the adsorption and decomposition of

    bacteria are only effective for substances that are

    collected on and in direct contact with the Titanium

    Apatite Photocatalytic Air-Purifying Filter.

    Bacteria Removal Test

    Testing method: dropping method

    Result certificate: No. 012553-1 and 012553-2

    Testing organisation: Japan Spinners Inspecting Foundation

    Titanium ApatitePhotocatalyticAir-purifying Filter

    Air filterCatches dust

  • 8/19/2019 Catalogue Daikin VRV IV S

    19/34

    Specifications

    35 36

    VRV  Indoor Units

    Ceiling Mounted Cassette (Double Flow) Type

    Ceiling Mounted Cassette Corner Type

    FXCQ20MVE FXCQ25MVE  FXC Q32MVE   FXCQ40MVE   FXCQ50MVE   FXCQ63MVE FXCQ80MVE   FXCQ125MVE

    1-phase, 220-240 V/220 V, 50/60 Hz

    1,900 2,400 3,100 3,900 4,800 6,100 7,700 12,000

    7,500 9,600 12,300 15,400 19,100 24,200 30,700 47,800

    2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0

    0.077 0.092 0.092 0.130 0.130 0.161 0.209 0.256

    Galvanised steel plate

    7/5 9/6.5 9/6.5 12/9 12/9 16.5/13 26/21 33/25

    2 47 /1 77 3 18 /2 30 3 18 /2 30 4 24 /3 18 4 24 /3 18 5 82 /4 59 9 18 /7 41 1 ,1 65 /8 83

    32/27 34/28 34/28 34/29 34/29 37/32 39/34 44/38

    305×775×600 305×775×600 305×775×600 305×990×600  305×990×600   305×1,175×600 305×1,665×600 305×1,665×600

    26.0 26.0 26.0 31.0 32.0 35.0 47.0 48.0

    6.4 6.4 6.4 6.4 6.4 9.5 9.5 9.5

    12.7 12.7 12.7 12.7 12.7 15.9 15.9 15.9

    VP25 (External Dia, 32/Internal Dia, 25)

    BYBC32G-W1 BYBC50G-W1   BYBC63G-W1 BYBC125G-W1

    White (10Y9/0.5)

    53×1,030×680 53×1,030×680 53×1,030×680 53×1,245×680 53×1,245×680 53×1,430×680 53×1,920×680 53×1,920×680

    8.0 8.0 8.0 8.5 8.5 9.5 12.0 12.0

    cfm

    dB(A)

    mm

    kg

    mm

    mm

    kg

    kcal/h

    Btu/h

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Model

    Colour

    Dimensions(H×W×D)

    Weight

    Power consumption

    Casing

    Sound level (H/L)

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Panel(Option)

    Power supply

    Cooling capacity

    MODEL

    Cooling

    Airflow rate (HH/M/L)

    220 V

    240 V

    FXKQ25MAVE

    9,600

    2,400

    Galvanised steel plate

    11/9

    FXKQ32MAVE

    12,300

    3,100

    FXKQ40MAVE

    15,400

    3,900

    FXKQ63MAVE

    2.8 3.6 4.5 7.1

    24,200

    6,100

    11/9 13/10 18/15

    388/318 388/318 459/353 635/530

    215X1,110X710

    31

      6.4

      12.7

    VP25 (External Dia, 32/Internal Dia, 25)

    BYK45FJW1

    White (10Y9/0.5)

    70X1,240X800

    8.5

    215X1,110X710

    31

      6.4

      12.7

    70X1,240X800

    8.5

    215X1,110X710

    31

      6.4

      12.7

    70X1,240X800

    8.5

    215X1,310X710

    34

      9.5

      15.9

    BYK71FJW1

    70X1,440X800

    9.5

    38/33 38/33 40/34 42/37

    1-phase, 220-240 V/220 V, 50/60 Hz

    Note: Specifications are based on the following conditions;•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5  m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: (FXCQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

    (FXKQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    0.066 0.066 0.076 0.105

    cfm

    mm

    kg

    mm

    mm

    kg

    kcal/h

    Btu/h

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Model

    Colour

    Dimensions(H×W×D)

    Weight

    Power consumption

    Casing

    Sound level (H/L)

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Panel(Option)

    Power supply

    Cooling capacity

    MODEL

    Cooling

    kW

    220 V

    240 VdB(A)

    Airflow rate (H/L)

    Ceiling Mounted Cassette (Compact Multi Flow) Type

    1-phase, 220-240 V/220 V, 50/60 Hz

    1,900

    7,500

    2.2

    2,400

    9,600

    2.8

    3,100

    12,300

    3.6

    0.076

    3,900

    15,400

    4.5

    0.089

    4,800

    19,100

    5.6

    0.115

    Galvanised steel plate

    9/7 9.5/7.5 11/8 14/10

    318/247 335/265 388/282 493/353

    30/25-32/26 32/26-34/28 36/28-37/29 41/33-42/35

    286×575×575

    18

    6.4

    12.7

    VP20 (External Dia, 26/Internal Dia, 20)

    BYFQ60B3W1

    White (6.5Y9.5/0.5)

    55×700×700

    2.7

    F XZ Q2 0M VE F XZ Q2 5M VE F XZ Q3 2M VE F XZ Q5 0M VEFXZQ40MVE

    0.073

    cfm

    dB(A)

    mm

    kg

    mm

    mm

    kg

    kcal/h

    Btu/h

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Model

    Colour

    Dimensions(H×W×D)

    Weight

    Casing

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Panel(Option)

    Power supply

    Cooling capacity

    MODEL

    Cooling

    Airflow rate (H/L)

    Sound level(H/L)

    230 V, 50 Hz-240 V, 50 Hz

    Power consumption

    34/29 36/30 36/30 37/32 37/32 39/34 41/36 46/40

    40/35 40/35 42/36 44/39

    Ceiling Mounted Cassette (Round Flow) Type

    1-phase, 220-240 V, 50 Hz

    2,400

    9,600

    2.8

    0.033

    3,100

    12,300

    3.6

    0.033

    3,900

    15,400

    4.5

    0.047

    4,800

    19,100

    5.6

    0.052

    13/11.5/10

    459/406/353

    30/28.5/27

    15/13/11

    530/459/388

    31/29/27

    16/13.5/11

    565/477/388

    32/29.5/27

    FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1

    Galvanised steel plate

    6,100 7,700 9,600 12,000

    24,200 30,700 38,200 47,800

    7.1 9.0 11.2 14.0

    0.066 0.093 0.187 0.209

    19/16.5/13.5

    671/583/477

    34/31/28

    32/26/20

    1,130/918/706

    43/37.5/32

    33/28/22.5

    1,165/989/794

    44/39/34

    21/18/15

    742/636/530

    36/33.5/31

    FXFQ63LUV1 FXFQ80LUV1 FXFQ100LUV1 FXFQ125LUV1

      9.5

      15.9

    VP25 (External Dia, 32/Internal Dia, 25)

    BYCP125K-W1

    Fresh white

    50X950X950

    5.5

      6.4

      12.7

    13/11.5/10

    459/406/353

    30/28.5/27

    cfm

    dB(A)

    mm

    kg

    mm

    mm

    kg

    kcal/h

    Btu/h

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Model

    Colour

    Dimensions(H×W×D)

    Weight

    Casing

    Sound level (HH/H/L)

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Panel(Option)

    Power supply

    Cooling capacity

    MODEL

    Cooling

    Airflow rate (HH/H/L)

    22 25

    246X840X840 288X840X840

    19.5

    Power consumption

    Note: Specifications are based on the following conditions;•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.(See Engineering Data Book for details.)•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

    During actual operation, these values are normally somewhat higher as a result of ambient conditions.

     

  • 8/19/2019 Catalogue Daikin VRV IV S

    20/34

    Specifications

    37 38

    VRV  Indoor Units

    Middle Static Pressure Ceiling Mounted Duct Type

    Note: Specifications are based on the following conditions;•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

      •Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.(See Engineering Data Book for details.)

    •Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

      1: Power consumption value is the value when airflow rate is maximum at maximum external static pressure position.  2: External static pressure can be modified using a remote controller that offers thirteen (FXSQ20-40P), eleven (FXSQ50-125P)

    or ten (FXSQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The rated staticpressure is 50 Pa.

    15,4003,900

    530/441/371

    19,1004,800

    600/512/406

    4.5 5.6

    15/12 .5 /10.5 17/14 .5 /11.5

    11111

    11111

    7,5001,900

    318/265/230

    2.2

    9/7.5/6.5

    9,6002,400

    318/265/230

    2.8

    9/7.5/6.5

    12,3003,100

    335/282/247

    3.6

      6.4

      12.7

    9.5/8/7

    VP25 (External Dia, 32/Internal Dia, 25)

    24,200

    6,100

    741/618/512

    30,700

    7,700

    812/688/565

    38,200

    9,600

    1,130/953/794

      9.5

      15.9

    47,800

    12,000

    1,306/1,112/918

    7.1 9.0 11.2 14.0

    21/ 17.5/14.5 23/19.5/16 32/27/22.5 37/ 31. 5/26

    36/32/29 37.5/34/30 39/35/32 42/38.5/35

    54,600

    13,800

    1,377/1,183/988

    16.0

    39/33.5/28

    43/40/36

    F XSQ 20 PVE F XSQ 25 PVE F XS Q3 2P VE F XSQ 40 PV E F XS Q5 0P VE

    0.104

    0.222 0.230 0.331 0.360 0.411

    0.104 0.111 0.162 0.164

    245X1,000X800245X700X800245X550X800

    352725

    34/32/2936/33/3034/32/3033/30/28

    cfm

    Pa

    dB(A)

    mm

    kg

    mm

    kcal/hBtu/h

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Power consumption

    Casing

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Power supply

    Cooling capacity

    MODEL

    Cooling

    External static pressure

    Sound level (H/M/L)

    cfm

    Pa

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Power consumption

    Casing

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Power supply

    Cooling capacity

    MODEL F XSQ63PVE F XSQ80PVE   FXSQ100PVE

    1-phase, 220-240 V/220 V, 50/60 Hz

    Galvanised steel plate

    245X1,400X800

    4637

    245X1,000X800

    35 47

    245X1,550X800

    52

    FXSQ125PVE FXSQ140PVE

    Cooling

    External static pressure

    Sound level (H/M/L)

    Airflow rate (H/M/L)

    Airflow rate (H/M/L)

    230-150 (50) 250-150 (50)

    250-150 (50) 250-140 (50)

    1-phase, 220-240 V/220 V, 50/60 Hz

    Galvanised steel plate

    VP25 (External Dia, 32/Internal Dia, 25)

    Slim Ceiling Mounted Duct Type (Standard Series)

    Slim Ceiling Mounted Duct Type (Compact Series)

    Note: Specifications are based on the following conditions;•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 5.0 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

    During actual operation, these values are normally somewhat higher as a result of ambient conditions.1 : Values are based on the following conditions: FXDQ20-32SP: external static pressure of 10 Pa; FXDQ40-63SP: external static pressure of 20 Pa.2 : External static pressure is changeable to set by the remote controller. This pressure means “High static pressure - Standard”. (Factorysetting is 10

    Pa for FXDQ20-32SP models and 20 Pa for FXDQ40-63SP models.)3 : The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).

    FXDQ20SPV1 FXDQ25SPV1 FXDQ32SPV1 FXDQ40SPV1 FXDQ50SPV1 FXDQ63SPV1

    2

    Galvanised steel plate

    1-phase, 220-240 V, 50 Hz

    1,900

    7,500

    2.2

    0.072

    2,400

    9,600

    2.8

    0.075

    3,100

    12,300

    3.6

    0.078

    3,900

    15,400

    4.5

    0.180

    4,800

    19,100

    5.6

    0.180

    6,100

    24,200

    7.1

    0.196

    9.0/8.0/7.0

    318/282/247

    30-10

    8.7/7.6/6.5

    307/268/229

    10.0/9.0/8.0

    353/318/282

    2

    15.0/13.0/10.5

    530/459/371

    50-20

    35/33/31

    200×900×450

    20

    2

    33/31/29

    200×700×450

    17

    VP20 (External Dia, 26/Internal Dia, 20)

    34/32/30

    cfm

    Pa

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Casing

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Power supply

    Cooling capacity

    MODEL

    Cooling

    External static pressure

    Sound level (HH/H/L)

    Airflow rate (HH/H/L)m3/min

    Power consumption 1

    6.4

    12.7

    20.0/16.0/12.5

    706/565/441

    40-20

    37/35/33

    200×1,100×450

    23

    9.5

    15.9

    1 3

    700 mm width type

    900/1,100 mmwidth type

    FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE

    FXDQ20PBVET FXDQ25PBVET FXDQ32PBVET

    FXDQ40NBVE

    FXDQ40NBVET

    FXDQ50NBVE

    FXDQ50NBVET

    FXDQ63NBVE

    FXDQ63NBVET

    1-phase, 220-240 V/220 V, 50/60 Hz1,900

    7,500

    2.2

    2,400 3,100

    12,300

    3.6

    9,600

    2.8

    0.086

    Galvanised steel plate

    8 .0 /7 .2 /6 .4 8 .0 /7 .2 /6 .4 8 .0 /7 .2 /6 .4

    282/254/226 282/254/226 282/254/226

    28/26/23 28/26/24

    200×700×620 200×700×620 200×700×620

    23.0 23.0 23.0

    VP20 (External Dia, 26/Internal Dia, 20)

    Note: Specifications are based on the following conditions;•Cooling: Indoor temp.: 27�DB, 19�WB, Outdoor temp.: 35�DB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    •Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    1 : Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.2 : External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is

    10 Pa for FXDQ-PB models and 15 Pa for FXDQ-NB models.)3 : The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).

    3,900 4,800 6,100

    15,400 19,100 24,200

    4.5 5.6 7.1

    10.5/9.5/8.5 12.5/11.0/10.0 16.5/14.5/13.0

    371/335/300 441/388/353 583/512/459

    30/28/26 33/30/27 33/31/29

    200×900×620 200×900×620 200×1,100×620

    27.0 28.0 31.0

    cfm

    Pa

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Power consumption(FXDQ-PBVET)

    Power consumption(FXDQ-PBVE)

    Casing

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Power supply

    Cooling capacity

    MODEL

    Cooling

    Cooling

    with drain pump

    without drain pump

    External static pressure

    Sound level (HH/H/L)

    Airflow rate (HH/H/L)

    1 3

    30-10 2

    1

    1

    44-15 2

    6.4 6.4 6.4

    12.712.712.7

    6.4

    12.7 12.7 15.9

    6.4 9.5

    0.067 0.152 0.168

    0.165 0.181

    0.1470.0700.067

    0.1470.0700.067

  • 8/19/2019 Catalogue Daikin VRV IV S

    21/34

    Specifications

    39 40

    VRV  Indoor Units

    Ceiling Mounted Duct Type

    • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.(See Engineering Data Book for details.)

    • Sound level: (FXMQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.(FXUQ-A)  Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.

      During actual operation, these values are normally somewhat higher as a result of ambient conditions  1: Power consumption values are based on conditions of standard external static pressure.  2: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "Standard-High static pressure".

     

    FXMQ200MAVE FXMQ250MAVE

    76,40019,300

    22.4 28.0

    95,50024,100

    1-phase, 220-240 V/220 V, 50/60 Hz

    Galvanised steel plate

    58/50

    2,047/1,765

    470X1,380X1,100

    137

      9.5

      19.1

    PS1B

    72/62

    2,542/2,189

    470X1,380X1,100

    137

      9.5

      22.2

    132-221 191-2702 2

    48/45 48/45

    49/46 49/46

    1.294 1.465

    cfm

    Pa

    mm

    kg

    mm

    kcal/hBtu/h

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Brazing)

    Drain

    Power consumption

    Casing

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Power supply

    Cooling capacity

    MODEL

    Cooling

    External static pressure

    Sound level(H/L)220 V

    240 VdB(A)

    Airflow rate (H/L)

    Ceiling Mounted Duct Type

    Note: Specifications are based on the following conditions;•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.(See Engineering Data Book for details.)

    •Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

      1: Power consumption values are based on conditions of rated external static pressure.  2: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P), thirteen (FXMQ40P), fourteen (FXMQ50-

    125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The standard staticpressure is 50 Pa for FXMQ20-32P and 100 Pa for FXMQ40-140P.

    15,400

    3,900

    565/459/388

    19,100

    4,800

    635/582/530

    4.5 5.6

      6.4

      12.7

      6.4

      12.7

    16/13/11 18/16.5/ 15

    11111

    11111

    7,500

    1,900

    318/265/230

    2.2

      6.4

      12.7

    9/7.5/6.5

    9,600

    2,400

    318/265/230

    2.8

      6.4

      12.7

    9/7.5/6.5

    12,300

    3,100

    335/282/247

    3.6

      6.4

      12.7

    9.5/8/7

    VP25 (External Dia, 32/Internal Dia, 25)

    24,200

    6,100

    688/618/565

      9.5

      15.9

    30,700

    7,700

    883/794/706

      9.5

      15.9

    38,200

    9,600

    1,130/953/812

      9.5

      15.9

    47,800

    12,000

    1,377/1,165/988

      9.5

      15.9

    7.1 9.0 11.2 14.0

    19.5/17.5/16 25/22.5/20 32/27/23 39/33/28

    42/40/38 43/41/39 43/41/39 44/42/40

    54,600

    13,800

    1,624/1,377/1,130

      9.5

      15.9

    16.0

    46/39/32

    46/45/43

    F XM Q2 0P VE F XM Q2 5P VE F XM Q3 2P VE F XM Q4 0P VE F XM Q5 0P VE

    0.056

    0.138 0.185 0.215 0.284 0.405

    0.056 0.060 0.151 0.128

    300X1,000X700300X700X700300X550X700300X550X700300X550X700

    3628252525

    41/39/3739/37/3534/32/3033/31/2933/31/29

    cfm

    Pa

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Power consumption

    Casing

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Power supply

    Cooling capacity

    MODEL

    Cooling

    External static pressure

    Sound level (HH/H/L)

    cfm

    Pa

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/hkW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Power consumption

    Casing

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Power supply

    Cooling capacity

    MODEL F XMQ63PVE F XM Q80PVE   FXMQ100PVE

    1-phase, 220-240 V/220 V, 50/60 Hz

    Galvanised steel plate

    300X1,400X700

    46

    300X1,000X700

    36

    300X1,000X700

    36

    300X1,400X700

    46

    300X1,400X700

    47

    FXMQ125PVE FXMQ140PVE

    Cooling

    External static pressure

    Sound level (HH/H/L)

    Airflow rate (HH/H/L)

    Airflow rate (HH/H/L)

    230-100 (50) 230-100 (50) 230-100 (50) 230-160 (100) 250-200 (100)

    250-200 (100)250-200 (100)250-200 (100)250-200 (100) 250-140 (100)

    1-phase, 220-240 V/220 V, 50/60 Hz

    Galvanised steel plate

    VP25 (External Dia, 32/Internal Dia, 25)

    1 1

    4-Way Flow Ceiling Suspended Type

    1-phase, 220-240 V/220-230 V, 50/60 Hz

    6,900 9,600

    27,300 38,200

    8.0

    0.090

    11.2

    0.200

    Fresh white

    22.5/19.5/16 31/26/21

    794/688/565 1,094/918/741

    40/38/36 47/44/40

    198×950×950

    26 27

    9.5

    15.9

    VP20 (External Dia, 26/Internal Dia, 20)

    FXUQ71AVEB FXUQ100AVEB

    cfm

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Casing

    Sound level (H/M/L)

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Power supply

    Cooling capacity

    MODEL

    Cooling

    Airflow rate (H/M/L)

    Power consumption

  • 8/19/2019 Catalogue Daikin VRV IV S

    22/34

    Specifications

    41 42

    VRV  Indoor Units

    Wall Mounted Type

    Floor Standing Type/Concealed Floor Standing Type

    Floor Standing Duct Type

    FXLQ

    FXNQ

    •Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.(See Engineering Data Book for details.)

    •Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE1-phase, 220-240 V/220 V, 50/60 Hz

    1,900 2,400 3,100 3,900 4,800 6,100

    7,500 9,600 12,300 15,400 19,100 24,200

    2.2 2.8 3.6 4.5 5.6 7.1

    0.019 0.028 0.030 0.020 0.033 0.050

    0.049 0.049 0.090 0.090 0.110 0.110

    White (3.0Y8.5/0.5)

    7.5/4.5 8/5 8.5/5.5 12/9 15/12 19/14

    265/159 282/177 300/194 424/318 530/424 671/494

    35/31 36/31 38/31 42/3739/34 47/41

    290×795×238 290×795×238 290×795×238 290×1,050×238 290×1,050×238 290×1,050×238

    11.0 11.0 11.0 14.0 14.0 14.0

    6.4 6.4 6.4 6.4 6.4 9.5

    12.7 12.7 12.7 12.7 12.7 15.9

    VP13 (External Dia, 18/Internal Dia, 13)

    FXLQ50MAVE

    FXNQ50MAVE

    FXLQ40MAVE

    FXNQ40MAVE

    FXLQ32MAVE

    FXNQ32MAVE

    FXLQ25MAVE

    FXNQ25MAVE

    FXLQ20MAVE

    FXNQ20MAVE

    FXLQ63MAVE

    FXNQ63MAVE

    1-phase, 220-240 V/220 V, 50/60 Hz

    1,900 2,400 3,100 3,900 4,800 6,100

    7,500 9,600 12,300 15,400 19,100 24,200

    2.2 2.8 3.6 4.5 5.6 7.1

    FXLQ: Ivory white (5Y7.5/1)/FXNQ: Galvanised steel plate

    7/6 7/6 8/6 11/8.5 14/11 16/12

    247/212 247/212 282/212 388/300 494/388 565/424

    35/32 35/32 35/32 38/33 39/34 40/35

    600×1,000×222 600×1,000×222 600×1,140×222 600×1,140×222 600×1,420×222 600×1,420×222

    610×930×220 610×930×220 610×1,070×220 610×1,070×220 610×1,350×220 610×1,350×220

    25.0 25.0 30.0 30.0 36.0 36.0

    19.0 19.0 23.0 23.0 27.0 27.0

    6.4 6.4 6.4 6.4 6.4 9.5

    12.7 12.7 12.7 12.7 12.7 15.9

    21O.D.

    cfm

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Power consumption

    Casing

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Power supply

    Cooling capacity

    MODEL

    Cooling

    Sound level (H/L)

    Power consumption

    Casing

    Power supply

    Cooling capacity

    MODEL

    Cooling

    Airflow rate (H/L)

    Rp1 (PS 1B internal thread)

    Long-life filter (anti-mould resin net)

    Belt drive system

    3-phase 4-wire system, 380–415 V, 50 Hz

    Ivory white (5Y7.5/1)

    FXVQ125NY1

    1,670×750×510

    118

    52

      15.9 (Brazing)

    FXVQ250NY1FXVQ200NY1

    0.53

    12,000

    47,800

    14.0

    19,300

    76,400

    22.4

    24,100

    95,500

    28.0

    1.611.33

    1,670×1,170×510

    169

    60

      22.2 (Brazing)

    1,670×950×510

    144

    56

      9.5 (Brazing)

      19.1 (Brazing)

    0.75

    43

    1,518

    1.5

    69

    2,436

    1.5

    86

    3,036

    152 217 281

    Notes: Specifications are based on the following conditions;•Cooling : Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.•Capacity of indoor unit is only f or reference. Actual capacity of indoor unit is based on the total capacity index.  (See Engineering Data Book for details.)*1 Sound level : measured when the air discharge outlet duct (2 m) is attached (anechoic chamber conversion value).

    It increases by approximately 5 dB(A) when the plenum chamber is installed to deliver direct airflow.*2 The value is the external static pressure with standard pulley.

    mm

    kg

    dB(A)

    mm

    mmmm

    kW

    m3/min

    cfm

    Pa

    kcal/h

    Btu/h

    kW

    kW

    Liquid

    GasDrain

    Type

    Motor output

    Airflow rate

    Externalstaticpressure*2

    Drive system

    Power consumption

    Casing colour

    Sound level *1

    Dimensions (H×W×D)

    Machine weight

    Piping

    connections

    Power supply

    Cooling capacity

    MODEL

    Cooling

    Air filter

    Fan

    cfm

    dB(A)

    kcal/h

    Btu/h

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Machine weight

    Pipingconnections

    Sound level (H/L)

    Dimensions(H×W×D)

    FXLQ

    FXNQ

    FXLQ

    FXNQ

    mm

    kg

    mm

    Airflow rate (H/L)

    •Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    Capacity of indoor unit is only f or reference. Actual capacity of indoor unit is based on the total capacity index.

    (See Engineering Data Book for details.)•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.

    During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    220 V

    240 V 37/34 37/34 37/34 40/35 41/36 42/37

    Ceiling Suspended Type

    FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE

    1-phase, 220-240 V/220 V, 50/60 Hz

    3,100 6,100 9,600

    12,300 24,200 38,200

    3.6 7.1 11.2

    0.111 0.115 0.135

    White (10Y9/0.5)

    12/10 17.5/14 25/19.5

    424/353 618/494 883/688

    36/31 39/34 45/37

    195×960×680 195×1,160×680 195×1,400×680

    24.0 28.0 33.0

    VP20 (External Dia, 26/Internal Dia, 20)

    cfm

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kW

    m3/min

    Liquid (Flare)

    Gas (Flare)

    Drain

    Power consumption

    Casing

    Dimensions (H×W×D)

    Machine weight

    Pipingconnections

    Power supply

    Cooling capacity

    MODEL

    Cooling

    Sound level (H/L)

    Airflow rate (H/L)

    6.4

    12.7 15.9 15.9

    9.5 9.5

  • 8/19/2019 Catalogue Daikin VRV IV S

    23/34

    Specifications

    43 44

    Residential Indoor Units with connection to BP units

    Wall Mounted Type

    BP Units for connection to residential indoor units

    Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 30 Pa for FDKS-EA and 40 Pa

      for FDKS-C. Sound level values for bottom-suction operation can be obtained by adding 6 dB (A) for FDKS-EA and 5 dB (A) for FDKS-C.

    8.7 (307)

    200X700X620 200X900X620 200X1,100X620

    3027

    40

    25

    VP20 (External Dia. 26/Internal Dia. 20)

    Both liquid and gas pipes

    21

    30

    9 .5 (3 35 ) 1 0.0 (3 53 ) 1 2. 0 (4 24 )

    37/33/3135/31/29

    16.0 (565)

    38/34/32

    1-phase, 220-240 V/220-230 V, 50/60 Hz

    5 steps, quiet and automatic

    Microcomputer control

    MODEL

    Power supply

    Airflow rates (H) m3/min(cfm)

    Sound levels (H/L/SL)* dB (A)

    Fan speed

    Temperature control

    Dimensions (HXWXD) mm

    kg

    mm

    Pa

    Machine weight

    Liquid (Flare)

    Gas (Flare)

    Drain

    Pipingconnections

    Heat insulation

    External static pressure

      9.5

      6.4

      12.7

    Note: * Total auxiliary piping length.

    1-phase, 220-240 V/220-230 V, 50/60 Hz

    10

    0.05

    180X294 (+356*)X350

    3 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP, BP-BP),4 for interu