catalogue 50hz bs
DESCRIPTION
pupmTRANSCRIPT
-
469
Pressure Boosting SetsPressure Boosting Sets
48
Fixed speed pump units
Variable speed pump units with frequency converter
giovanniCasella di testo09/2013
-
470
IndexIndex
TO SELECT A PRESSURE BOOSTING SET page 621
MINIMAT, TURBOMAT
CENTRIMAT, GETTOMAT
pag. 476
Small automatic water systems
with 1 pump series
MXH, MGP, MXP, NM, NG, MXA
NGL, NGX
BS2Fpag. 505
Variable speed pump pressure boosting sets for domestic use with 2 MGP, MXP, NM, NMD
BS1V1F, BS2V
Fixed speed pump pressure boosting sets for domestic use with 2MGP, MXP, NM, NMD, NG, NGL, NGX
BS .F
Variable speed pump pressure boosting sets for civil use with 1-2-3 MXH
BS1V.F, BS.V
Fixed speed pump pressure boosting sets for civil use with 1-2-3 MXH
BS.F
Variable speed pump pressure boosting sets for civil use with 1-2-3 MXSU
BS1V.F, BS.V
Fixed speed pump pressure boosting sets for civil use with 1-2-3 MXSU
BS.F
Variable speed pump pressure boosting sets for civil use with 1-2-3 NM, NMD
BS1V.F, BS.V
Fixed speed pump pressure boosting sets for civil use with 1-2-3 NM, NMD
BS.F
Variable speed pump pressure boosting sets for civil use with 1-2-3 MXV
BS1V.F, BS.V
Fixed speed pump pressure boosting sets for civil use with 1-2-3 MXV
pag. 486
Constant pressure boosting sets
with Easymat frequency converter
with 1 or 2
MGP, MXP, MXH, MXSU, MXVB, 4SDF
EASYMAT
pag. 499
Constant pressure boosting sets
with Easymat frequency converter
with 1 or 2
MXH, MXVB
VARIOMAT 2
pag. 518
pag. 525
BS.F
Variable speed pump pressure boosting sets for civil use with 1-2-3 MXVB
BS1V.F, BS.V
Fixed speed pump pressure boosting sets for civil use with 1-2-3 MXVB
pag. 530
pag. 537
pag. 545
Variable speed pump (on-board frequency converter) pressure boosting sets for civil use with 1-2-3 MXVE
BS1V.F, BS.V
pag. 549
-
471
Designation
48
BS M 2F 2 MXV 25/204
BS M 2V 2 MXV 25/204
Pump type
Pump type
Nr of pumps
Nr of pumps
Product series
2F
M
3F1V1F1V2F
2V3V
2 fixed speed pumps1F 1 fixed speed pump
3 fixed speed pumps1 variable speed pump and 1 fixed speed pump1 variable speed pump and 2 fixed speed pumps
2 variable speed pumps1V 1 variable speed pump
3 variable speed pumps
BS M 1V 1F 2 MXV 25/204
Sigle-phase supply(no indication: three-phase supply)
Sigle-phase supply
MT Three-phase motor
T Three-phase supply
Sigle-phase motor
E= EASYMAT series, V= VARIOMAT series
2 MXH 204 - E MT2 MXH 204 - E MM
Product series
Tank capacity (litres)
With tank under the pump(no indication: tank above the pump)
Pump type
CENTRIMAT MXH 205E /24CENTRIMAT 1/1 MXH 205E /20
Pressure Boosting SetsPressure Boosting Sets
To select a Pressure Boosting Set see chap. 52 technical appendix at page 621.For booster sets with 4, 5 and 6 pumps contact our Technical Sales Department.
-
472
BSF with fixed speed pumps
ConstructionPressure boosting sets with automatic opera-tion, consisting in 2 and 3 pumps on a commonbaseplate, with sunction and deliverymanifolds, gate and non-return valves, pressu-re switches, pressure gauge, control panel andfrom 100 to 1000 litres diaphragm tank (onrequest).
OperationThe control panel, with electronic card, mana-ges the pump operation, the changeover ofpump starting sequence and it stops thesystem when there is no air in the tank (paten-ted system).Pumps starting in a cascade sequence, with asignal from the pressure switches.
H
Q 3
BS 3F 3 pompe a velocit fissa
H
Q 3
BS 2F 2 pompe a velocit fissa
Stop
Start
Stop
Start
m
m /h
m
m /h
MINIMAT with 1 fixed speed pump
ConstructionSmall pressure boo-sting sets with automa-tic operation, consistingof pump, pressure swit-ch and 1 litre diaphragmtank.
OperationPump is directly driven by the pressure switch.
TURBOMAT, CENTRIMAT,GETTOMATwith 1 fixed speed pump
ConstructionSmall pressure boosting sets with automaticoperation, consisting of with pump, pressureswitch, pressure gauge and diaphragm tank(24litres if above the pump, 20litres if underthe pump).
OperationPump is directly driven by the pressureswitch..
EASYMAT with 1 variable speed pump
ConstructionPressure boosting sets withautomatic operation and con-stant pressure, consisting ofa variable speed pump dri-ven by Easymat frequencyconverter, with gate and non-return valves, pressuregauge, 8 litres diaphragmtank (on request).
OperationVariable speed pump is directly driven byVariomat frequency converter.
EASYMATwith 2 variable speed pumps
ConstructionPressure boosting sets with automatic opera-tion and constant pressure, made up with 2variable speed pumps on a common basepla-te driven by Easymat frequency converter,with suction and delivery manifolds, gate andnon-return valves, pressure gauge, 8 litresdiaphragm tank and control panel with twomagnetothermal switches.
OperationPumps starting in a cascade sequence, withchangeover of pump starting sequence.
BS 3F 3 pompe a velocit fissa
BS 2F 2 pompe a velocit fissa
F F
F FF
Operation
H
H set Stop
Start
Q 3
EASYMAT1 pompa a velocit variabile
H
Q 3
MINIMAT1 pompa a velocit fissa
m
m /h
m
m /h
F
1 l
F
Var.
H
H set Stop
Start
Q 3
EASYMAT1 pompa a velocit variabile
H
Q 3
MINIMAT1 pompa a velocit fissa
m
m /h
m
m /h
F
24 l
F F
Var. Var.
BS 2F2 fixed speed pumps
BS 3F3 fixed speed pumps
BS 2F2 fixed speed pumps
BS 3F3 fixed speed pumps
MINIMAT1 fixed speed pump
EASYMAT1 variable speed pump
TURBOMAT, CENTRIMAT, GETTOMAT1 fixed speed pump
EASYMAT2 variable speed pumps
-
473
BSV.F.with variable and fixed speedpumps (frequency converterinto the control panel)
ConstructionPressure boosting sets with automa-tic operation, consisting of 1 variablespeed pump with frequency conver-ter into the control panel and from 1to 5 fixed speed pumps, assembledon a common baseplate, with suctionand delivery manifolds, gate andnon-return valves, pressure gauge,control panel and 20 litres diaph-ragm tank (on request).
OperationThe control panel, with electronic card,manages the pump operation, the changeo-ver of fixed speed pumps starting sequence Pumps starting is in a cascade sequence,with a signal from the pressure transducer.Constant pressure is guaranteed by thevariable speed pumps, while fixed speedpumps start when the request is higher thanthe capacity of the variable speed pump.
BSVwith variable speed pumps(frequency converter into thecontrol panel)
ConstructionPressure boosting sets with auto-matic operation, consisting of varia-ble speed pumps (from 1 to 6) withfrequency converter on the controlpanel, assembled on a commonbaseplate, with suction and deliverymanifolds, gate and non-return val-ves, pressure transducer, pressuregauge, control panel and 20 litresdiaphragm tank (on request).
OperationThe control panel, with electroniccard, manages the pump operation,the changeover of pumps startingsequence.Pumps starting in a cascadesequence, with a signal from thepressure transducer.
BSV.F.with variable speed pumps(on board frequency converter)
ConstructionPressure boosting sets with automa-tic operation, consisting of 1 variablespeed pump with frequency conver-ter into the control panel and from 1to 5 fixed speed pumps, assembledon a common baseplate, with suctionand delivery manifolds, gate andnon-return valves, pressure gauge,control panel and 20 litres diaph-ragm tank (on request).
OperationThe control panel, with electronic card, mana-ges the pump operation, the changeover offixed speed pumps starting sequence Pumps starting is in a cascade sequence,with a signal from the pressure transducer.Constant pressure is guaranteed by thevariable speed pumps, while fixed speedpumps start when the request is higher thanthe capacity of the variable speed pump.
BSVwith variable speed pumps(on board frequency converter)
ConstructionPressure boosting sets with automa-tic operation, consisting of variablespeed pumps (from 1 to 6) with fre-quency converter on the controlpanel, assembled on a commonbaseplate, with suction and deliverymanifolds, gate and non-return val-ves, pressure transducer, pressuregauge, control panel and 20litresdiaphragm tank (on request).
OperationThe control panel, with electroniccard, manages the pump operation,the changeover of pumps startingsequence.Pumps starting in a cascadesequence, with a signal from thepressure transducer.
H
H set
Q 3
BS 1V2F 3 pompe: 1 variabile 2 fisse
H
H set
Q 3
BS 1V1F 2 pompe: 1 variabile 1 fissa
H
H set
Q 3
BS 3V 3 pompe a velocit variabile
H
H set
Q 3
BS 2V 2 pompe a velocit variabile
H
H set
Q 3
BS 1V2F3 pompe: 1 variabile 2 fisse
H
H set
Q 3
BS 1V1F 2 pompe: 1 variabile 1 fissa
H
H set
Q 3
BS 3V 3 pompe a velocit variabile
H
H set
Q 3
BS 2V 2 pompe a velocit variabile
m
m /h
m
m /h
m
m /h
m
m /h
m
m /h
m
m /h
m
m /h
m
m /h
BS 1V2F 2 pompe: 1 variabile 2 fisse
BS 3V 3 pompe a velocit variabile
BS 1V1F 2 pompe: 1 variabile 1 fissa
BS 2V 2 pompe a velocit variabile
BS 1V2F3 pompe: 1 variabile 2 fisse
BS 3V 3 pompe a velocit variabile
BS 1V1F 2 pompe: 1 variabile 1 fissa
BS 2V 2 pompe a velocit variabile
V F
V FF
V V
V VV
V F
V FF
V V
V VV
INVERTER INVERTER INVERTER
INVERTER INVERTER INVERTER INVERTER
48
BS 1V1F2 pumps: 1variable
1 fixed
BS 2V2 variable speed pumps
BS 1V1F2 pumps: 1variable
1 fixed
BS 2V2 variable speed pumps
BS 1V2F3 pumps: 1variable
2 fixed
BS 3V3 variable speed pumps
BS 1V2F3 pumps: 1variable
2 fixed
BS 3V3 variable speed pumps
BS 1V1F2 pumps: 1variable
1 fixed
BS 2V2 variable speed pumps
BS 1V1F2 pumps: 1variable
1 fixed
BS 2V2 variable speed pumps
BS 1V2F3 pumps: 1variable
2 fixed
BS 3V3 variable speed pumps
BS 1V2F3 pumps: 1variable
2 fixed
BS 3V3 variable speed pumps
-
474
Fixed speed pump units
New electrical control panelsfor fixed speed pump units.New electrical control panels for pressurisation units, all withelectronic card with microprocessors, for managing pumpoperation.
The microprocessor carries out continuous secure checks duringall the various work phases of the pumps and incorporates allnecessary functions, thus reducing electrical and electroniccomponents inside the panel.
In particular:- pumps starting in a cascade sequence according to water
demand.- changeover of pump starting sequence.- delay start-up of the 2nd/3rd pump in case of breakdown of
pressure switch 1 or after a power cut.- avoid pump starting in case of water hammering.- activate the alarm when pressure 1 fails.- activate the alarm when air cushion in the vessel drops.- stop the pump when air cushion is over*.* Patent pending
Maximum clarity for all signalsThe status of the unit can easily be identified on the front of theelectronic card with the following signals:- Power on led.- No water led.- Failure led.- Pump running led (1 for each pump).- Thermal block led (1 for each pump).- Pump automatic operation led (1 for each pump).- Pump stop led (1 for each pump).
Maximum simplicity of controlThe front of electronic card features the following signals and controls:- AUT-STOP push-button (1 for each pump)- MAN push-button (1 for each pump)- RESET push-button.
Optional remote controlThe new panels have been designed to remotely reproduce all the electronic card signals (excluding the buttons), using RC 100 - RC 200 - RC 300panels, connected with a simple two-pole cable.The RA 100 panel enables a remote warning light and acoustic signal.
Control panel for units up to 6 pumpsUsing the MPS 6000 (Multi Pumps System) electronic card it is possible to control pressure units up to a maximum of 6 fixed speed pumps with asingle pressure calibration.
Automatic air supply systemsThe pump control panels are completed by microprocessor controlled systems for automatic air supply in the pressure vessels by means of acompressor or solenoid valve.
OperationFor booster sets made up to three pumps: according to the pressure decrease in the system, the pressure switches make the pumps to start in
cascade mode and the starting changeover is made by the microprocessor. For sets made of 4, 5, 6 pumps: Operation controlled by a microprocessor with signal from a pressure transducer. The pumps operate with only one
pressure setting.
Pressure Boosting SetsPressure Boosting Sets
-
475
Pressure Boosting SetsPressure Boosting Sets
Variable speed pump units with frequency converter
New electrical control panelsfor variable speed pump units.New electrical control panels for pressurisation units with variablespeed pumps.These are indispensible in all those cases where constant pressureis required and when high pressure pumps are being controlled.All the various working phases are managed and controlled by theMPS 6000 (Multi Pumps System) electronic card with microproces-sor, which can operate up to 6 pumps working simultaneously.
Maximum clarity of signalsAll the various calibration parameters appear as messages on thedisplay of the MPS 6000 electronic card.If there are any faults or defects a message appears on the displaygiving details of the problem.
Possibility of remote controlThe pump status can be displayed and the unit can be controlled bymeans of a special computer program.It is possible to obtain a remote warning light and acoustic signal onthe RA 100 panel.
Constant or increased pressureAll the pumps can work with the same pressure value (set point), or, forsystems with high head losses, the pressure can be increaseddepending on the number of pumps operating.
Silent operationMotors working at reduced speed and check valves that close gradually mean that operation is particularly quite.
Long life for pumpsAll the mechanical components of the pumps and motors are stressed to a minimum, due to the variable speed operation.
Energy savingsThe motors consume only the precise level of power necessary moment to moment, in order to supply the quantity of water required by the system.
No more high capacity vesselsThe use of inverters means that high capacity pressure vessels and membrane vessels are no longer necessary. Even units with high flowrate pumpsonly require a small number of 20 litre membrane vessels.
Great versatilityThe great versatility of the MPS 6000 electronic card enables the construction of special units with operational logics different from those of normal pres-surisation units, depending on the requirements and characteristics of the systems.
OperationDepending on water consumption, one or more pumps are activated, all at variable speed, in order to guarantee the quantity of water required at the setpressure.
48
-
476
ConstructionCompact, automatic autoclaves for household water feeding, consisting of: - close-coupled pump - membrane tank - pressure switch - pressure gauge (excluding MINIMAT)- special connector - flexible pipe for systems with pump over the vessel
OperationAccording to the decrease or increase of pressure, the pressure switch determines when the pump will start or stop.
ApplicationsFor drawing water out a well.As pressure boosting pump for central water systems with thermal protector (follow specifications if increasing network pressure).
Motors2-pole induction motors, 50 Hz, n 2900 rpm.Three-phase 230/400V 10%.Single-phase 230V 10%, with thermal protector.Insulation class F.Protection IP 54.Constructed in accordance with: IEC 60034.Other voltages and frequencies on request.
VesselsSpherical with capacity 24 litres, or cylindrical with capacity 20 litres, membrane type, air preordaining with pressure 0,2 bar below the minimumpressure switch rating.Capacity of the MINIMAT vessel 1 liter.
MINIMAT - TURBOMAT - CENTRIMATMINIMAT - TURBOMAT - CENTRIMAT - GETTOMAT- GETTOMATSmall automatic water systems
-
477
4.93.108
B
DN2
DN
1
L
H
MINIMATMINIMAT Systems with liquid ring CA and peripheral pumps CT
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
CT 61/1 CTM 61/1 0,33 0,45 30 1,42,8 G1 G1 180 255 280 8CA80E/1 CAM 80E/1 0,45 0,6 32 1,42,8 G 3/4 G1 180 255 330 11,5
MINIMAT
MINIMAT
MINIMAT
Coverage chart
Characteristic, dimensions and weights
0
0
0
20
50
0 2.5
10030
40
80
120
60
40
2
2 10
0.5 1 1.5 2
140
160
4 6 8
4 6 8Imp.g.p.m.
U.S. g.p.m.
ftm
m /hl/min
10
20
0
0 10 20 30 40
H
CT 61
CA 80E
H
Q3
72.852.C
CT 61
CA 80E
* Maximum pump flow at minimum set pressure of pressure switch.
48
-
478
4.93.316
L B
H
DN2
DN1
DN1
DN2
L B
H
3.93.049
TURBOMATTURBOMAT Systems with peripheral pumps series T, TP
0
0
00
1 2 3 4
5 10 15
5 10
U.S. g.p.m.
Imp. g.p.m.
m /h
20
80
40
100
60
m
0
0 l/min 20 40 60
100
200
300
ft
3
72.940.C
T - TP
T 70/AT 65E
TP 80E
T 61E
Q
H
H
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
T 61E/24 TM 61E/24 0,33 0,45 32 1,42,8 G1 G1 400 560 13,3T 65E/24 TM 65E/24 0,45 0,6 43 1,42,8 G1 G1 400 560 13,3T 70/A/24 TM 70/A/24 0,75 1 50 2,03,5 G1 G1
360430 575 17,7
TP 80E/24 TPM 80E/24 0,75 1 22 4,06,0 G 3/4 G1 485 575 22
TURBOMAT
TURBOMAT TURBOMAT 1/1
Q3~ 230/400V 1~ 230 V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
T 61E/20 TM 61E/20 0,33 0,45 32 1,42,8 G1 G1 508 25T 65E/20 TM 65E/20 0,45 0,6 43 1,42,8 G1 G1 508 25T 70/A/20 TM 70/A/20 0,75 1 50 2,03,5 G1 G1
255 530526 29
TP 80E/20 TPM 80E/20 0,75 1 22 4,06,0 G 3/4 G1 526 32,2
TURBOMAT 1/1
TURBOMAT
TURBOMAT 1/1
Coverage chart
Characteristic, dimensions and weights
* Maximum pump flow at minimum set pressure of pressure switch.
TURBO
-
479
4.93.316
L B
H
DN2
DN1
H
B
DN2
DN1
L
3.93.045
CENTRIMATCENTRIMAT Systems with centrifugal pumps series NM, NMD
NMDNM
20/140AE
20/140BE
20/110A/A
20/110Z/A20/110B/A
1/AE2/S/A
2/B/A
2/A/A20/140AE
1
3
0 Imp.g.p.m.
0 U.S. g.p.m.
10
20
30
40
40
60
80
100
120
1 3 4 5
5 10 15 20
5 10 15
m
m /h
ft
620 40 60 80 100l/min
0 Imp.g.p.m.
0 U.S. g.p.m.
10
30
50
70
100
1 3 4 5
5 10 15 20
5 10 15
m
m /h
ft
620 40 60 80 100l/min
20
40
200
150
50
H
Q
HH
Q
H
3
72.941.1.C
3
72.941.2.C
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
NM 1/AE/24 NMM 1/AE/24 0,37 0,5 73 1,01,8 G1 G1 400 620 17,7NM 2/B/A/24 NMM 2/B/A/24 0,55 0,75 80 1,42,4 G1 G1 440 650 21,4NM 2/S/A/24 NMM 2/S/A/24 0,55 0,75 80 1,42,8 G1 G1 440 650 21,5NM 2/A/A/24 NMM 2/A/A/24 0,75 1 100 2,03,0 G1 G1 440 650 22,7NMD 20/110B/A/24 NMDM 20/110B/A/24 0,45 0,6 60 1,42,8 G 11/4 G1
360430 635 21,2
NMD 20/110Z/A/24 NMDM 20/110Z/A/24 0,55 0,75 70 1,83,2 G 11/4 G1 430 635 22,3NMD 20/110A/A/24 NMDM 20/110A/A/24 0,75 1 70 2,23,6 G 11/4 G1 430 635 23,4NMD 20/140BE/24 NMDM 20/140BE/24 1,1 1,5 80 3,55,0 G 11/4 G1 510 670 30,7
NMDM 20/140AE/24 1,5 2 80 3,45,4 G 11/4 G1 510 670 33NMD 20/140AE/24 1,5 2 90 4,46,4 G 11/4 G1 510 670 32
CENTRIMAT
Characteristic, dimensions and weights
Coverage chart
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
NM 1/AE/20 NMM 1/AE/20 0,37 0,5 73 1,01,8 G1 G1 567 18,5NM 2/B/A/20 NMM 2/B/A/20 0,55 0,75 80 1,42,4 G1 G1 600 22,2NM 2/S/A/20 NMM 2/S/A/20 0,55 0,75 80 1,42,8 G1 G1 600 22,3NM 2/A/A/20 NMM 2/A/A/20 0,75 1 100 2,03,0 G1 G1 600 23,5NMD 20/110B/A/20 NMDM 20/110B/A/20 0,45 0,6 60 1,42,8 G 11/4 G1
255 530582 22
NMD 20/110Z/A/20 NMDM 20/110Z/A/20 0,55 0,75 70 1,83,2 G 11/4 G1 582 23,1NMD 20/110A/A/20 NMDM 20/110A/A/20 0,75 1 70 2,23,6 G 11/4 G1 582 24,2NMD 20/140BE/20 NMDM 20/140BE/20 1,1 1,5 80 3,55,0 G 11/4 G1 619 31,5
NMDM 20/140AE/20 1,5 2 80 3,45,4 G 11/4 G1 619 33NMD 20/140AE/20 1,5 2 90 4,46,4 G 11/4 G1 619 32
CENTRIMAT 1/1
CENTRIMAT CENTRIMAT 1/1
CENTRIMAT
CENTRIMAT 1/1
* Maximum pump flow at minimum set pressure of pressure switch.
48
-
480
4.93.281
L B
H
4.93.316
DN2
DN1
CENTRIMATCENTRIMAT Systems with Multi-Stage series MGP
MGP 404
0 1 2 3 4 50 20 40 60 80
20
30
40
50
10
0
50
0
100
150
ft
5 10 15 20Imp. g.p.m.0
72.1143.1 72.1143.2
MGP 204
MGP 203
0 2 4 6 80 50 100
20
30
40
50
10
0
0 10
50
100
150
ft
20Imp. g.p.m.
MGP 403
0
0 10 20 30U.S. g.p.m.U.S. g.p.m.0 5 10 15 20
MGP MGPHm
m /hl/minQ
3
Hm
m /hl/min
3
Q
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
MGP 203/24 MGPM 203/24 0,45 0,6 65 1,22,4 G 1 G1 427 583 14MGP 204/24 MGPM 204/24 0,55 0,75 70 2,03,5 G 1 G1 456 583 15MGP 403/24 MGPM 403/24 0,55 0,75 110 1,22,4 G 1 G1
360456 583 15
MGP 404/24 MGPM 404/24 0,75 1 110 2,03,5 G 1 G1 456 583 16
CENTRIMAT
CENTRIMAT CENTRIMAT 1/1
Characteristic, dimensions and weights
Coverage chart
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
MGP 203/20 MGPM 203/20 0,45 0,6 65 1,22,4 G 1 G1 530 516 15MGP 204/20 MGPM 204/20 0,55 0,75 70 2,03,5 G 1 G1 530 516 16MGP 403/20 MGPM 403/20 0,55 0,75 110 1,22,4 G 1 G1
255530 516 16
MGP 404/20 MGPM 404/20 0,75 1 110 2,03,5 G 1 G1 530 532 17
CENTRIMAT 1/1
CENTRIMAT
* Maximum pump flow at minimum set pressure of pressure switch.
DN2
DN1
4.93.316
L BH
CENTRIMAT 1/1
-
481
4.93.281
L B
H
4.93.316
DN2
DN1
CENTRIMATCENTRIMAT Systems with Multi-Stage stainless steel series MXP
0 1 2 3 4 50 20 40 60 80
20
30
40
50
10
0
50
0
100
150
ft
5 10 15 20Imp. g.p.m.0
72.1143.1 72.1143.2
MXP 204
MXP 203/A
0 2 4 6 80 50 100
20
30
40
50
10
0
0 10
50
100
150
ft
20Imp. g.p.m.
MXP 404/A
MXP 403/A
0
0 10 20 30U.S. g.p.m.U.S. g.p.m.0 5 10 15 20
MXP MXPHm
m /hl/minQ
3
Hm
m /hl/min
3
Q
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
MXP 203/24 MXPM 203/24 0,45 0,6 65 1,22,4 G 1 G1 427 583 14MXP 204/A/24 MXPM 204/A/24 0,55 0,75 70 2,03,5 G 1 G1 456 583 15MXP 403/A/24 MXPM 403/A/24 0,55 0,75 110 1,52,7 G 1 G1
360456 583 15
MXP 404/A/24 MXPM 404/A/24 0,75 1 110 2,03,5 G 1 G1 456 583 16
CENTRIMAT
CENTRIMAT CENTRIMAT 1/1
Characteristic, dimensions and weights
Coverage chart
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
MXP 203/20 MXPM 203/20 0,45 0,6 65 1,22,4 G 1 G1 530 532 15MXP 204/A/20 MXPM 204/A/20 0,55 0,75 70 2,03,5 G 1 G1 530 532 16MXP 403/A/20 MXPM 403/A/20 0,55 0,75 110 1,52,7 G 1 G1
255530 532 16
MXP 404/A/20 MXPM 404/A/20 0,75 1 110 2,03,5 G 1 G1 530 532 17
CENTRIMAT 1/1
CENTRIMAT
* Maximum pump flow at minimum set pressure of pressure switch.
48
DN2
DN1
4.93.316
L BH
CENTRIMAT 1/1
-
482
L B
H
3.93.047
DN2
DN1
CENTRIMATCENTRIMAT Systems with Multi-Stage stainless steel series MXH
0 2 4 6 80 50 100
20
30
40
50
60
10
0 10 20 30
10
50
100
150
ft
20
U.S. g.p.m.
H
MXH MXHm
m /hl/minQ
MXH 405/A
MXH 404/A
MXH 403/A
3
72.942.1.C 72.942.2.C
0 Imp. g.p.m.
0 1 2 3 4 50 20 40 60 80
20
30
40
50
60
10
50
100
150
ft
5 10 15Imp. g.p.m.0
U.S. g.p.m.0 5 10 15 20
Hm
m /hl/min
3
Q
MXH 205/A
MXH 204/A
MXH 203E
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
MXH 203E/24 MXHM 203E/24 0,45 0,6 70 1,42,8 G 11/4 G1 417 590 15MXH 204/A/24 MXHM 204/A/24 0,55 0,75 62 2,54,0 G 11/4 G1 443 590 16,5MXH 205/A/24 MXHM 205/A/24 0,75 1 65 2,54,5 G 11/4 G1 443 590 18MXH 403/A/24 MXHM 403/A/24 0,55 0,75 120 1,52,7 G 11/4 G1 360 443 590 16MXH 404/A/24 MXHM 404/A/24 0,75 1 110 2,03,5 G 11/4 G1 443 590 17,5
MXHM 405/24 1,1 1,5 115 2,54,5 G 11/4 G1 502 590 23,5MXH 405/B/24 1,1 1,5 115 2,54,5 G 11/4 G1 443 590 18,5
CENTRIMAT
CENTRIMAT CENTRIMAT 1/1
Characteristic, dimensions and weights
Coverage chart
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
MXH 203E/20 MXHM 203E/20 0,45 0,6 70 1,42,8 G 11/4 G1 530 540 16MXH 204/A/20 MXHM 204/A/20 0,55 0,75 62 2,54,0 G 11/4 G1 530 540 17,5MXH 205/A/20 MXHM 205/A/20 0,75 1 65 2,54,5 G 11/4 G1 530 540 19MXH 403/A/20 MXHM 403/A/20 0,55 0,75 120 1,52,7 G 11/4 G1 255 530 540 17MXH 404/A/20 MXHM 404/A/20 0,75 1 110 2,03,5 G 11/4 G1 530 540 18,5
MXHM 405/20 1,1 1,5 115 2,54,5 G 11/4 G1 530 540 24,5MXH 405/B/20 1,1 1,5 115 2,54,5 G 11/4 G1 530 540 19,5
CENTRIMAT 1/1
CENTRIMAT
* Maximum pump flow at minimum set pressure of pressure switch.
3.93.048
L B
H
DN2
DN1
CENTRIMAT 1/1
-
483
CENTRIMATCENTRIMAT Systems with Multi-Stage Self-Priming pumpsseries MXA
0 2 4 6 80 50 100
20
30
40
50
60
10
0 10 20 30
10
50
100
150
ft
20
U.S. g.p.m.
H
MXA MXAm
m /hl/minQ
MXA 405
MXA 404/A
MXA 403/A
3
72.942.1.C 72.942.2.C
0 Imp. g.p.m.
0 1 2 3 4 50 20 40 60 80
20
30
40
50
60
10
50
100
150
ft
5 10 15Imp. g.p.m.0
U.S. g.p.m.0 5 10 15 20
Hm
m /hl/min
3
Q
MXA 205
MXA 204/A
MXA 203
CENTRIMAT CENTRIMAT 1/1
Characteristic, dimensions and weights
Coverage chart
* Maximum pump flow at minimum set pressure of pressure switch.
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
MXA 203/24 MXAM 203/24 0,45 0,6 62 1,22,4 G 1 G1 427 583 13MXA 204/A/24 MXAM 204/A/24 0,55 0,75 66 2,03,5 G 1 G1 456 583 16MXA 205/24 MXAM 205/24 0,75 1 66 2,54,5 G 11/4 G1 529 626 22MXA 403/A/24 MXAM 403/A/24 0,55 0,75 108 1,52,7 G 1 G1
360456 583 16
MXA 404/A/24 MXAM 404/A/24 0,75 1 108 2,03,5 G 1 G1 456 583 17MXA 405/24 MXAM 405/24 1,1 1,5 105 2,54,5 G 11/4 G1 529 626 23
CENTRIMAT
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
MXA 203/20 MXAM 203/20 0,45 0,6 62 1,22,4 G 1 G1 530 532 14MXA 204/A/20 MXAM 204/A/20 0,55 0,75 66 2,03,5 G 1 G1 530 532 17MXA 205/20 MXAM 205/20 0,75 1 66 2,54,5 G 11/4 G1 530 575 23MXA 403/A/20 MXAM 403/A/20 0,55 0,75 108 1,52,7 G 1 G1
255530 532 17
MXA 404/A/20 MXAM 404/A/20 0,75 1 108 2,03,5 G 1 G1 530 532 18MXA 405/20 MXAM 405/20 1,1 1,5 105 2,54,5 G 11/4 G1 530 575 24
CENTRIMAT 1/1
DN2
DN1
4.93.316
L BH
4.93.281
L B
H
4.93.316
DN2
DN1
CENTRIMAT
CENTRIMAT 1/1
48
-
484
DN1
4.93.316
L B
H
DN2
GETTOMAT 1/1
DN2
DN1
H
L B
3.93.051
GETTOMATGETTOMAT Systems with Self-Priming jet pumps series NG, NGL
NGL 3/A
NGL 2 NGL 4/A
NGL 2,3,4NG 3,4
NG 5/16ENG 6/22ENG 7/22/A
5/16E
6/22E
6/22E 3 ~
1 ~
7/22E
NG 3/A
NG 4/A
020
2 4 6 8 100 40 80 120 160
100
0 10 20 30
0 10 20 30 40
30
70
m /hl/min
U.S. g.p.m.
Imp. g.p.m.
mft
0
20
1 2 3 4 50 20 40 60 80
0 5 10 15
0 5 10 15 20U.S. g.p.m.
Imp. g.p.m.
m
ft
40
50
30 100
50
150
50
150
200
l/minm /h
60
H
Q
H
H
Q
H
33
72.943.1.C 72.943.2.C
Characteristic, dimensions and weights
Coverage chart
GETTOMAT GETTOMAT 1/1
GETTOMAT
* Maximum pump flow at minimum set pressure of pressure switch.
Q3~ 230/400V 1~ 230V max * Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
NGL 2/24 NGLM 2/24 0,45 0,6 35 2,03,5 G 1 G1 427 583 14,5NGL 3/A/24 NGLM 3/A/24 0,55 0,75 45 2,54,0 G 1 G1 456 583 16,5NGL 4/A/24 NGLM 4/A/24 0,75 1 72 2,03,5 G 1 G1 456 583 17,5NG 3/A/24 NGM 3/A/24 0,55 0,75 50 2,54,0 G1 G1
480610 25,1
NG 4/A/24 NGM 4/A/24 0,75 1 65 2,03,5 G1 G1 360 610 28,9NG 5/16E/24 NGM 5/16E/24 1,1 1,5 65 3,55,0 G 11/2 G1 650 35,5
NGM 6/22E/24 1,5 2 140 2,54,0 G 11/2 G1570
650 37,5
NG 6/22E/24 1,5 2 140 2,54,5 G 11/2 G1 650 37,5NG 7/22/A/24 - 2,2 3 150 3,55,0 G 11/2 G1 650 39,5
GETTOMAT
Q3~ 230/400V 1~ 230V max * Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
NGL 2/20 NGLM 2/20 0,45 0,6 35 2,03,5 G 1 G1 516 15,5NGL 3/A/20 NGLM 3/A/20 0,55 0,75 45 2,54,0 G 1 G1 516 17,5NGL 4/A/20 NGLM 4/A/20 0,75 1 72 2,03,5 G 1 G1 530 516 18,5NG 3/A/20 NGM 3/A/20 0,55 0,75 50 2,54,0 G1 G1
255548 26
NG 4/A/20 NGM 4/A/20 0,75 1 65 2,03,5 G1 G1 548 29,7NG 5/16E/20 NGM 5/16E/20 1,1 1,5 65 3,55,0 G 11/2 G1 577 36,2
NGM 6/22E/20 1,5 2 140 2,54,0 G 11/2 G1 580 577 38,5NG 6/22E/20 1,5 2 140 2,54,5 G 11/2 G1 577 38,5NG 7/22/A/20 - 2,2 3 150 3,55,0 G 11/2 G1 600 577 40
GETTOMAT 1/1
-
485
DN2
DN1
4.93.316
L B
H
GETTOMAT 1/1
4.93.281
L B
H
4.93.316
DN2
DN1
NGX 3/A
NGX 2NGX 4/A
NGX NGX 5/16NGX 6/22
020
2 4 6 8 100 40 80 120 160
100
0 10 20 30
0 10 20 30 40
30
70
m /hl/min
U.S. g.p.m.
Imp. g.p.m.
mft
0
20
1 2 3 4 50 20 40 60 80
0 5 10 15
0 5 10 15 20U.S. g.p.m.
Imp. g.p.m.
m
ft
40
50
30 100
50
150
50
150
200
l/minm /h
60
H
Q
H
H
Q
H
33
72.1144 72.1144.1
NGX 5/16
NGX 5/22
NGX 6/22
GETTOMAT GETTOMAT 1/1
Characteristic, dimensions and weights
Coverage chart
GETTOMAT
GETTOMATGETTOMAT Systems with Self-Priming jet pumps series NGX
48
* Maximum pump flow at minimum set pressure of pressure switch.
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
NGX 2/24 NGXM 2/24 0,45 0,6 35 2,03,5 G 1 G1 427 583 14,5NGX 3/A/24 NGXM 3/A/24 0,55 0,75 45 2,54,0 G 1 G1 456 583 16,5NGX 4/A/24 NGXM 4/A/24 0,75 1 72 2,03,5 G 1 G1 360 456 583 17,5NGX 5/16/24 NGXM 5/16/24 1,1 1,5 62 3,55,0 G 11/4 G1 528 626 23,5NGX 6/22/24 NGXM 6/22/24 1,5 2 150 2,54,0 G 11/4 G1 528 626 25,5
GETTOMAT
Q3~ 230/400V 1~ 230V max* Pres. switch mm
kW HP l/min bar DN1 DN2 B L H kg
NGX 2/20 NGXM 2/20 0,45 0,6 35 2,03,5 G 1 G1 530 532 15,5NGX 3/A/20 NGXM 3/A/20 0,55 0,75 45 2,54,0 G 1 G1 530 532 17,5NGX 4/A/20 NGXM 4/A/20 0,75 1 72 2,03,5 G 1 G1 255 530 532 18,5NGX 5/16/20 NGXM 5/16/20 1,1 1,5 62 3,55,0 G 11/4 G1 530 575 24,5NGX 6/22/20 NGXM 6/22/20 1,5 2 150 2,54,0 G 11/4 G1 530 575 26,5
GETTOMAT 1/1
-
486
1MXP.EM,1MXP.EM, 1MGP.EM,1MGP.EM, 1MXH.EM,1MXH.EM, 1MXSU.EM, 1MXVB.EM1MXSU.EM, 1MXVB.EMConstant pressure boosting sets with EASYMAT frequency converter
ExecutionConstant pressure boosting sets with one pump and EASYMAT frequency converter
Ball valve and non return valve on suction side, ball valve and pressure gauge on delivery side
Suitable for installation of a 8-lt cylindrical pressure vessel on delivery side
EASYMAT device:
Frequency converter installed directly on the pump delivery pipe and water cooled (patented).
Only three parameters to set at starting:
- Maximum motor current
- Working frequency
- Working pressure
Possibility to display:
- Pressure of the system
- Working frequency
- Absorbed current
- Alarms
OperationCONSTANT PRESSURE MODE:
the system keeps the pressure constant when the quantity of water requested by the user changes.
According to the water consumption, the pump at variable speed ensures the required water quantity at the set pressure
FIXED SPEED MODE:
the system works at a fixed speed that user can choose according to his need.
ApplicationsFor drawing water out of a well
As pressure boosting pump for central water systems with low pressure (follow local specifications if increasing network pressure)
Motors2-pole induction motors, 50Hz, n 2900 rpm, suitable for operation with frequency converter
- Single-phase 230V +/-10%
- Three-phase 230V +/-10%
Class F insulation
IP 54 protection
Execution according IEC 60034
Other voltages on demand
Pressure vessels (on demand)Cylindrical with capactiy 8 liters, membrane type, air precharged
-
487
G 1
G 1
G 1
G 1
680
680
127
127
495
495
95
95
269
269
165
165
146
146
516516545516545545
0 1 2 3 4 50 20 40 60 80
20
30
40
50
10
0
50
0
100
150
ft
5 10 15 20Imp. g.p.m.0
Hm
m /hl/min
3
Q
204 1MXP 2 1MXP 4
203
202
0 2 4 6 80 50 100
20
30
40
50
10
0
0 10
50
0
100
150
ft
20Imp. g.p.m.
Hm
m /hl/minQ
404
403
402
3
DN2
4.93.334.1
DN1
L2
h1h2
L1
H
m1
B
B2
A kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
1 ~230 V 1 ~Aliment.: Aliment.:P2 mm
A
230 V 1 ~230 V 3 ~Motore: Motore: 230 V
1MXP 202-EMT1MXP 203-EMT1MXP 204/A-EMT1MXP 402-EMT1MXP 403/A-EMT1MXP 404/A-EMT
1MXPM 202-EMM1MXPM 203-EMM1MXPM 204/A-EMM1MXPM 402-EMM1MXPM 403/A-EMM1MXPM 404/A-EMM
1,72,42,82,42,83,5
0,330,450,550,450,550,75
0,450,60,750,60,75
1
2,33
4,23
4,25,4
A2,13,24
3,245
m
motore Aliment.
made in italy
1 MXP. EM1 MXP. EM Pressure boosting sets with one horizontal multi-stagepump with EASYMAT frequency converterCoverage chart
Characteristic and dimensions
Mains: 1~ 230VMotor: 3~ 230V
Mains: 1~ 230VMotor: 1~ 230V
mains motor
48
-
488
404
G 1
G 1
G 1
G 1
116
116
685
685
504
504
95
95
269
269
516
516516545
165
165
146
146
0 1 2 3 4 50 20 40 60 80
20
30
40
50
10
0
50
0
100
150
ft
5 10 15 20Imp. g.p.m.0
Hm
m /hl/min
3
Q
2041MGP 2 1MGP 4
203
202
0 2 4 6 80 50 100
20
30
40
50
10
0
0 10
50
0
100
150
ft
20Imp. g.p.m.
Hm
m /hl/minQ
403
402
3
DN2
4.93.334.1
DN1
L2
h1h2
L1
H
m1
B
B2
m
m
A kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
1 ~230 V 1 ~Aliment.: Aliment.:P2 mm
A
230 V 1 ~230 V 3 ~Motore: Motore: 230 V
1MGP 202-EMT1MGP 203-EMT1MGP 204-EMT1MGP 402-EMT1MGP 403-EMT1MGP 404-EMT
1MGPM 202-EMM1MGPM 203-EMM1MGPM 204-EMM1MGPM 402-EMM1MGPM 403-EMM1MGPM 404-EMM
1,72,42,82,43
3,5
0,330,450,550,450,550,75
0,450,60,750,60,75
1
2,33
3,33
3,55,4
Amotore Aliment.
2,13,24
3,24,35
made in italy
1 MGP. EM1 MGP. EM Pressure boosting sets with one horizontal multi-stagepump with EASYMAT frequency converterCoverage chart
Characteristic and dimensions
Mains: 1~ 230VMotor: 3~ 230V
Mains: 1~ 230VMotor: 1~ 230V
mains motor
-
489
DN2
4.93.334.1
DN1
L2
h1h2
L1
H
m1
B
B2
0 1 2 3 4 50 20 40 60 80
20
30
40
50
60
70
1050
100
150
ft
5 10 15Imp. g.p.m.0
200
Hm
m /hl/min
3
Q
205/A
206/A1MXH 2
1MXH 8
1MXH 4
204/A
203E
0 2 4 6 80 50 100
20
30
40
50
60
70
10
0 10
50
100
150
ft
20Imp. g.p.m.
Hm
m /hl/minQ
405/A
406
404/A
403/A
3
200
0 140
20
30
40
50
60
10
Imp g.p.m.0
4 6 8 10 1250 100 150 200
20 30 40 50
50
100
150
200
ft
805
804
803
Hm
m /hl/minQ
3
0 280
20
30
40
50
60
10
Imp g.p.m.0
8 12 16 20 24100 200 300 400
40 60 80 100
50
100
150
200
ft
1603
1MXH 16
1602
Hm
m /hl/minQ
3
G 1 1/4
G 1 1/4
G 1 1/2
G 2
G 1
G 1
G 1
G 1 1/2
708
708
708
750
127
127
127
117
516
516
516
560
88
88
88
101
165
165
165
165
146
146
146
146
511561585609537561585680657687717752752
274298322346274298322346323353383404404
m
A kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
1 ~230 V 1 ~Aliment.: Aliment.:P2 mm
A
230 V 1 ~230 V 3 ~Motore: Motore: 230 V
1MXH 203E-EMT1MXH 204/A-EMT1MXH 205/A-EMT1MXH 206/B-EMT1MXH 403/A-EMT1MXH 404/A-EMT1MXH 405/B-EMT1MXH 406-EMT1MXH 803-EMT1MXH 804-EMT1MXH 805/A-EMT1MXH 1602-EMT1MXH 1603/A-EMT
1MXHM 203E-EMM1MXHM 204/A-EMM1MXHM 205/A-EMM1MXHM 206-EMM1MXHM 403/A-EMM1MXHM 404/A-EMM1MXHM 405-EMM
1MXHM 803-EMM
2,42,83,54,72,83,54,76,25
6,27,56,27,5
0,450,550,751,10,550,751,11,51,11,51,81,51,8
0,60,75
11,5
0,751
1,52
1,52
2,52
2,5
34,25,47,44,25,47,4
7,4
A3,245
6,345
6,78
7,18,610,79,110,7
m
motore aliment.
made in italy
1 MXH. EM1 MXH. EM Pressure boosting sets with one horizontal multi-stagepump with EASYMAT frequency converterCoverage chart
Characteristic and dimensions
Mains: 1~ 230VMotor: 3~ 230V
Mains: 1~ 230VMotor: 1~ 230V
mains motor
48
-
490
DN2
4.93
.335
.1
DN1
H
h1h2
BB2
L2L1
m1
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
32
32
32
304
304
304
225
225
225
123
123
123
190
190
190
190
190
190
1071109511191071109510951095
9739971021973997997997
0 50
70
10
50
ft
0
20
30
40
50
60
Hm
1 2 3 420 40 60 80
5 10 15Imp g.p.m.
m /h3l/minQ
100
150
200206
205
204
203
0 80
20
30
40
50
60
10
0
50
100
150
ft
2 4 650 100
10 20
m /h3l/minQ
Imp g.p.m.
404
405
Hm
0 120
0
4 6 8 1050 100 150 200
20
30
40
50
50
100
150
ft
Hm
803
804
10
0 0
2010 30 40
m /h3l/minQ
Imp g.p.m.
m
m
m
A kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
1 ~230 V 1 ~Aliment.: Aliment.:P2 mm
A
230 V 1 ~230 V 3 ~Motore: Motore: 230 V
1MXSU 204/A-EMT1MXSU 205/A-EMT1MXSU 206/A-EMT1MXSU 404/A-EMT1MXSU 405/A-EMT1MXSU 803/A-EMT1MXSU 804/A-EMT
1MXSUM 204/A-EMM1MXSUM 205/A-EMM
2,73,33,83,84,54,56,6
0,550,750,90,91,11,11,5
0,751
1,21,21,51,52
4,1 5
A3,94,75,45,46,46,49,4
1MXSU 2 1MXSU 4
1MXSU 8
motore aliment.
made in italy
Coverage chart
Characteristic and dimensions
1 MXSU. EM1 MXSU. EM Pressure boosting sets with one vertical multi-stagepump with EASYMAT frequency converter
Mains: 1~ 230VMotor: 3~ 230V
Mains: 1~ 230VMotor: 1~ 230V
mains motor
-
491
DN1
DN2
4.93
.336
.1
h1h2 H
m1
L2
L1
B2
B
made in italy
m
1MXV-B 25-2 1MXV-B 32-4
1MXV-B 40-8
H
Q
4
5
6
7
8
10
3
H
Q
4
5
6
7
3
H
Q
4
3
7
G 1
G 1 1/4
G 1 1/2
G 1
G 1 1/4
G 1 1/2
577
600
623
75
75
80
437
458
470
588
633
675
262
288
318
150
150
190
218
218
246
210
210
246
1 ~230 V 1 ~Aliment.: Aliment.: 230 V 1 ~230 V 3 ~Motore: Motore: 230 V
0 50
0
0
20
40
60
80
100
120
1 2 3 40
100
200
300
5 10 15Imp. g.p.m.
ftm
20 40 60 8030 50 70m /hl/min
0 90
0
0
20
40
60
80
100
120
0
100
200
300
ftm
2 3 4 5 6 7 850 100 150
10 20 30Imp. g.p.m.
m /hl/min
0 140
0
0
20
40
60
80
100
0
100
200
300
ft
m
2 4 6 8 10 12
10 20 30 40 50Imp. g.p.m.
50 100 150 200m /hl/min
A kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
P2 mm
A1MXV-B 25-204-EMT1MXV-B 25-205-EMT1MXV-B 25-206-EMT1MXV-B 25-207-EMT1MXV-B 25-208-EMT1MXV-B 25-210-EMT1MXV-B 32-404-EMT1MXV-B 32-405-EMT1MXV-B 32-406-EMT1MXV-B 32-407-EMT1MXV-B 32-408-EMT1MXV-B 32-410-EMT1MXV-B 40-804-EMT1MXV-B 40-805-EMT1MXV-B 40-806-EMT
1MXV-BM 25-204-EMM1MXV-BM 25-205-EMM1MXV-BM 25-206-EMM1MXV-BM 25-207-EMM
1MXV-BM 32-404-EMM1MXV-BM 32-405-EMM
3,33,34,74,77,57,54,74,77,57,59,159,157,59,159,15
0,750,751,11,11,51,51,11,11,51,52,22,21,52,22,2
11
1,51,522
1,51,52233233
5,85,87,47,4
7,47,4
A5,45,47,17,110,810,87,17,110,810,813,213,210,813,213,2
motore aliment.
8
10
5
6
Coverage chart
Characteristic and dimensions
1 MXVB. EM1 MXVB. EM Pressure boosting sets with one vertical multi-stagepump with EASYMAT frequency converter
Mains: 1~ 230VMotor: 3~ 230V
Mains: 1~ 230VMotor: 1~ 230V
mains motor
48
-
492
547
190190
m /hl/min
3
Qm /hl/min
3
Q
m /hl/min
3
Qm /hl/min
3
Q
m /hl/min
3
Q
0
100
80
40
20
1200 3 4 5 6 7 8 9
0
100
200
300
0 10 15 20 25 30 35 400 0,5 1 1,5 2 2,5
19
14
9
6
0
100
80
60
40
20
80
60
40
20
80
60
40
20
80
60
40
20
0 4 6 8 10 12
0
100
200
300
0 20 30 40 50 600 1 2 3 3,6
14
10
7
4
0
1000 6 8 10 12 14 16 18
0
100
200
300
0 20 30 40 50 60 70 800 1 2 3 4 5
17
11
8
6
4
0
1000
0
100
200
300
0
0
20 30 40 50
3
60 70 80 90 100
6
15
10
7
5
10 20
4 52
100
100
200
300
0
0 10 20 30
0
0 40 60 80 100 120 1400 3 6
14
10
7
5
2 4 5 7 8
mH
mH
mH
mH
mH
ft
Imp. g.p.mImp. g.p.m
ft
ft
Imp. g.p.m
ftH
Imp. g.p.m
ftH
Imp. g.p.m
4SDF 16 4SDF 22
4SDF 36 4SDF 46
4SDF 54
G 1 1/4
G 1 1/4
963.93.063.2N
4SDF 16/6E-EMT4SDF 16/9E-EMT4SDF 16/14E-EMT4SDF 16/19E-EMT4SDF 22/4E-EMT4SDF 22/7E-EMT4SDF 22/10E-EMT4SDF 22/14E-EMT4SDF 36/4E-EMT4SDF 36/6E-EMT4SDF 36/8E-EMT4SDF 36/11E-EMT4SDF 36/17E-EMT4SDF 46/5E-EMT4SDF 46/7E-EMT4SDF 46/10E-EMT4SDF 46/15E-EMT4SDF 54/5E-EMT4SDF 54/7E-EMT4SDF 54/10E-EMT4SDF 54/14E-EMT
1.91.92.83.51.91.92.83.51.91.92.83.54.91.92.83.54.92.83.54.96.8
0.370.370.550.750.370.370.550.750.370.370.550.751.10.370.550.751.10.550.751.11.5
0.50.50.75
10.50.50.75
10.50.50.75
11.50.50.75
11.50.75
11.52
2.52.53.74.82.52.53.74.82.52.53.74.86.82.53.74.86.83.74.86.89.5
A kW HP
230 V 1 ~Aliment.:P2 230 V 3 ~Motore:
Amotore aliment.
made in italy
Coverage chart
Characteristic and dimensions
4SDF. EM4SDF. EM Pressure boosting sets with one submersible borehole pumpwith EASYMAT frequency converter
Mains: 1~ 230VMotor: 3~ 230V
mains motor
-
493
2MXP.EM,2MXP.EM, 2MGP.EM,2MGP.EM, 2MXH.EM,2MXH.EM, 2MXSU.EM, 2MXVB.EM2MXSU.EM, 2MXVB.EMConstant pressure boosting sets with EASYMAT frequency converter
ExecutionConstant pressure boosting sets with EASYMAT frequency converter made of two pumps, ball valve and non return valve on suction side, ball valve
and pressure gauge on delivery side.
Suction and delivery manifolds in stainless steel AISI 304.
Suitable for installation of a 8-lt cylindrical pressure vessel on delivery side.
EASYMAT device:
Frequency converter installed directly on the pump delivery pipe and water cooled (patented).
Only three parameters to set at starting:
- Maximum motor current
- Working frequency
- Working pressure
Possibility to display:
- Pressure of the system
- Working frequency
- Absorbed current
- Alarms
OperationAccording to the water consumption, one or more pumps starts, all at variable speed, to ensure the required water quantity at the set pressure.
CONSTANT PRESSURE MODE:
the system keeps the pressure constant when the quantity of water requested by the user changes.
FIXED SPEED MODE:
the system works at a fixed speed that user can choose according to his need.
ApplicationsFor drawing water out of a well
As pressure boosting pump for central water systems with low pressure (follow local specifications if increasing network pressure)
Motors2-pole induction motors, 50Hz, n 2900 rpm, suitable for operation with frequency converter
- Single-phase 230V +/-10%
- Three-phase 230V +/-10%
Class F insulation
IP 54 protection
Execution according IEC 60034
Other voltages on demand
Pressure vessels (on demand)Cylindrical with capactiy 8 liters, membrane type, air precharged
48
-
494
made in italymade in italy
G 2
G 2
G 1 1/2
G 1 1/2
841
841
150
150
510
510
240
240
600
600
625
625
573573602573602602
326
326
0
5
0 2 4 6 8 100 40 80 120 160
20
30
40
50
10
0
50
0
100
150
ft
10 20 30 40Imp. g.p.m.0
Hm
m /hl/min
3
Q
204
2MXP 2 2MXP 4
203
202
0 4 8 12 160 100 200
20
30
40
50
10
0
0 20
50
0
100
150
ft
40Imp. g.p.m.
Hm
m /hl/minQ
404
403
402
3
0
5
h2h1
H
B2
Bm1
L2
L1
DN1
DN2
A kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
1 ~230 V 1 ~Aliment.: Aliment.:P2 mm
A
230 V 1 ~230 V 3 ~Motore: Motore: 230 V
2MXP 202-EMT2MXP 203-EMT2MXP 204/A-EMT2MXP 402-EMT2MXP 403/A-EMT2MXP 404/A-EMT
2MXPM 202-EMM2MXPM 203-EMM2MXPM 204/A-EMM2MXPM 402-EMM2MXPM 403/A-EMM2MXPM 404/A-EMM
2 x 1,72 x 2,42 x 2,82 x 2,42 x 2,82 x 3,5
2 x 0,332 x 0,452 x 0,552 x 0,452 x 0,552 x 0,75
2 x 0,452 x 0,6
2 x 0,752 x 0,6
2 x 0,752 x 1
2 x 2,32 x 3
2 x 4,22 x 3
2 x 4,22 x 5,4
A2 x 2,12 x 3,22 x 4
2 x 3,22 x 42 x 5
m
motore Aliment.
Coverage chart
Characteristic and dimensions
2 MXP. EM2 MXP. EM Pressure boosting sets with two horizontal multi-stagepumps with EASYMAT frequency converter
Mains: 1~ 230VMotor: 3~ 230V
Mains: 1~ 230VMotor: 1~ 230V
mains motor
-
495
made in italymade in italy
0
5
404
G 2
G 2
G 1 1/2
G 1 1/2
825
825
150
150
494
494
240
240
326
326
573
573573602
600
600
625
625
0
5
0 2 4 6 8 100 40 80 120 160
20
30
40
50
10
0
50
0
100
150
ft
10 20 30 40Imp. g.p.m.0
Hm
m /hl/min
3
Q
204
2MGP 2 2MGP 4
203
202
0 4 8 12 160 100 200
20
30
40
50
10
0
0 20
50
0
100
150
ft
40Imp. g.p.m.
Hm
m /hl/minQ
403
402
3
h2h1
H
B2
Bm1
L2
L1
DN1
DN2
m
A kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
1 ~230 V 1 ~Aliment.: Aliment.:P2 mm
A
230 V 1 ~230 V 3 ~Motore: Motore: 230 V
2MGP 202-EMT2MGP 203-EMT2MGP 204-EMT2MGP 402-EMT2MGP 403-EMT2MGP 404-EMT
2MGPM 202-EMM2MGPM 203-EMM2MGPM 204-EMM2MGPM 402-EMM2MGPM 403-EMM2MGPM 403-EMM
2 x 1,72 x 2,42 x 2,82 x 2,42 x 3
2 x 3,5
2 x 0,332 x 0,452 x 0,552 x 0,452 x 0,552 x 0,75
2x 0,452 x 0,62 x 0,752 x 0,62 x 0,75
2 x 1
2 x 2,32 x 3
2 x 3,32 x 3
2 x 3,52 x 5,4
A2 x 2,12 x 3,22 x 4
2 x 3,22 x 4,32 x 5
m
motore Aliment.
Coverage chart
Characteristic and dimensions
2 MGP. EM2 MGP. EM Pressure boosting sets with two horizontal multi-stagepumps with EASYMAT frequency converter
Mains: 1~ 230VMotor: 3~ 230V
Mains: 1~ 230VMotor: 1~ 230V
mains motor
48
-
496
DN1
DN2
0 2 4 6 8 100 40 80 120 160
20
30
40
50
60
70
1050
100
150
ft
10 20 30Imp. g.p.m.0
200
Hm
m /hl/min
3
Q
5
6
2MXH 2
2MXH 8
2MXH 4
4
3
0 4 8 12 160 100 200
20
30
40
50
60
70
10
0 20
50
100
150
ft
40Imp. g.p.m.
Hm
m /hl/minQ
6
5
4
3
3
200
0 280
20
30
40
50
60
10
Imp g.p.m.0
8 12 16 20 2450 200 300 400
40 60 80 100
50
100
150
200
ft
5
4
3
Hm
m /hl/minQ
3
0 560
20
30
40
50
60
10
Imp g.p.m.0
16 24 32 40 48100 400 600 800
80 120 160 200
50
100
150
200
ft
3
2MXH 16
2
Hm
m /hl/minQ
3
made in italymade in italy
G 2
G 2
G 2 1/2
G 3
G 1 1/2
G 1 1/2
G 2
G 2 1/2
848
848
854
882
161
161
161
151
506
506
512
551
240
240
240
240
600
600
600
600
625
625
625
625
563613637661589613637732727757787829829
326350374398326350374398393423453481481
h2h1
H
B2
Bm1
L2
L1
A kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
1 ~230 V 1 ~Aliment.: Aliment.:P2 mm
A
230 V 1 ~230 V 3 ~Motore: Motore: 230 V
2MXH 203E-EMT2MXH 204/A-EMT2MXH 205/A-EMT2MXH 206/B-EMT2MXH 403/A-EMT2MXH 404/A-EMT2MXH 405/B-EMT2MXH 406-EMT2MXH 803-EMT2MXH 804-EMT2MXH 805/A-EMT2MXH 1602-EMT2MXH 1603/A-EMT
2MXHM 203E-EMM2MXHM 204/A-EMM2MXHM 205/A-EMM2MXHM 206-EMM2MXHM 403/A-EMM2MXHM 404/A-EMM2MXHM 405-EMM
2MXHM 803-EMM
2 x 2,42 x 2,82 x 3,52 x 4,72 x 2,82 x 3,52 x 4,72 x 6,22 x 5
2 x 6,22 x 7,52 x 6,22 x 7,5
2 x 0,452 x 0,552 x 0,752 x 1,1
2 x 0,552 x 0,752 x 1,12 x 1,52 x 1,12 x 1,52 x 1,82 x 1,52 x 1,8
2 x 0,62 x 0,75
2 x 12 x 1,5
2 x 0,752 x 1
2 x 1,52 x 2
2 x 1,52 x 2
2 x 2,52 x 2
2 x 2,5
2 x 32 x 4,22 x 5,42 x 7,42 x 4,22 x 5,42 x 7,4
2 x 7,4
A2 x 3,22 x 42 x 5
2 x 6,32 x 42 x 5
2 x 6,72 x 8
2 x 7,12 x 8,62 x 10,72 x 9,12 x 10,7
m
m
motore aliment.
Coverage chart
Characteristic and dimensions
2 MXH. EM2 MXH. EM Pressure boosting sets with two horizontal multi-stagepumps with EASYMAT frequency converter
Mains: 1~ 230VMotor: 3~ 230V
Mains: 1~ 230VMotor: 1~ 230V
mains motor
-
497
4.93.335.2m1
L2 B2B
L1
DN2
DN1
made in italymade in italy
G 2
G 2
G 2
G 2
G 2
G 2
66
66
66
417
417
417
277
277
277
240
240
240
600
600
600
625
625
625
1205122912531205122912291229
958982
1006958982982982
h2h1
H
m
m
A kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
1 ~230 V 1 ~Aliment.: Aliment.:P2 mm
A
230 V 1 ~230 V 3 ~Motore: Motore: 230 V
2MXSU 204/A-EMT2MXSU 205/A-EMT2MXSU 206/A-EMT2MXSU 404/A-EMT2MXSU 405/A-EMT2MXSU 803/A-EMT2MXSU 804/A-EMT
2MXSUM 204/A-EMM2MXSUM 205/A-EMM
2 x 2,72 x 3,32 x 3,82 x 3,82 x 4,52 x 4,52 x 6,6
2 x 0,552 x 0,752 x 0,92 x 0,92 x 1,12 x 1,12 x 1,5
2 x 0,752 x 1
2 x 1,22 x 1,22 x 1,52 x 1,52 x 2
2 x 4,1 2 x 5
A2 x 3,92 x 4,72 x 5,42 x 5,42 x 6,42 x 6,42 x 9,4
0 100
70
10
50
ft
0
20
30
40
50
60
Hm
2 4 6 840 80 120 160
10 20 30Imp g.p.m.
m /h3l/minQ
100
150
200
72.944.1C
206
205
204
2MXSU 2
72.944.3C
72.944.2C
0 160
20
30
40
50
60
10
0
50
100
150
ft
4 8 12100 200
20 40
m /h3l/minQ
Imp g.p.m.
404
405
Hm 2MXSU 4
0 240
0
8 12 16 20100 200 300 400
20
30
40
50
50
100
150
ft
Hm
10
0 0
4020 60 80
m /h3l/minQ
Imp g.p.m.
2MXSU 8
803
804
motore aliment.
Coverage chart
Characteristic and dimensions
2 MXSU. EM2 MXSU. EM Pressure boosting sets with two vertical multi-stagepumps with EASYMAT frequency converter
Mains: 1~ 230VMotor: 3~ 230V
Mains: 1~ 230VMotor: 1~ 230V
mains motor
48
-
498
DN2
DN1
4.93.336.2
m1
L2
L1H
B
B2
h1h2
made in italy made in italy
H
Q
45678
10
2MXV-B 25-2
3
H
Q
4567
2MXV-B 32-4
3
H
Q
4
2MXV-B 40-8
3
G 1 1/2
G 2
G 2 1/2
G 1 1/2
G 2
G 2 1/2
727
743
765
119
119
124
461
477
495
501
544
598
315
340
388
365
365
365
600
600
600
625
625
625
1 ~230 V 1 ~Aliment.: Aliment.: 230 V 1 ~230 V 3 ~Motore: Motore: 230 V
0 100
0
0
20
40
60
80
100
120
2 4 6 80
100
200
300
10 20 30Imp. g.p.m.
ftm
40 80 120 16060 100 140m /hl/min
0 180
0
0
20
40
60
80
100
120
0
100
200
300
ftm
4 6 8 10 12 14 16100 200 300
30 40 60Imp. g.p.m.
m /hl/min
0 280
0
0
20
40
60
80
100
0
100
200
300
ft
m
4 8 12 16 20 24
20 40 60 80 100Imp. g.p.m.
100 200 300 400m /hl/min
A kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
P2 mm
A2MXV-B 25-204-EMT2MXV-B 25-205-EMT2MXV-B 25-206-EMT2MXV-B 25-207-EMT2MXV-B 25-208-EMT2MXV-B 25-210-EMT2MXV-B 32-404-EMT2MXV-B 32-405-EMT2MXV-B 32-406-EMT2MXV-B 32-407-EMT2MXV-B 32-408-EMT2MXV-B 32-410-EMT2MXV-B 40-804-EMT2MXV-B 40-805-EMT2MXV-B 40-806-EMT
2MXV-BM 25-204-EMM2MXV-BM 25-205-EMM2MXV-BM 25-206-EMM2MXV-BM 25-207-EMM
2MXV-BM 32-404-EMM2MXV-BM 32-405-EMM
2 x 3,32 x 3,32 x 4,72 x 4,72 x 7,52 x 7,52 x 4,72 x 4,72 x 7,52 x 7,52 x 9,152 x 9,152 x 7,52 x 9,152 x 9,15
2 x 0,752 x 0,752 x 1,12 x 1,12 x 1,52 x 1,52 x 1,12 x 1,12 x 1,52 x 1,52 x 2,22 x 2,22 x 1,52 x 2,22 x 2,2
2 x 12 x 1
2 x 1,52 x 1,52 x 22 x 2
2 x 1,52 x 1,52 x 22 x 22 x 32 x 32 x 22 x 32 x 3
2 x 5,82 x 5,82 x 7,42 x 7,4
2 x 7,42 x 7,4
A2 x 5,42 x 5,42 x 7,12 x 7,1
2 x 10,82 x 10,82 x 7,12 x 7,1
2 x 10,82 x 10,82 x 13,22 x 13,22 x 10,82 x 13,22 x 13,2
motore aliment.
78
10
5
6
Coverage chart
Characteristic and dimensions
2 MXVB. EM2 MXVB. EM Pressure boosting sets with two vertical multi-stagepumps with EASYMAT frequency converter
Mains: 1~ 230VMotor: 3~ 230V
Mains: 1~ 230VMotor: 1~ 230V
mains motor
-
499
1MXH.VTT2,1MXH.VTT2, 1MXVB.VTT21MXVB.VTT2Constant pressure boosting sets with VARIOMAT 2 frequency converter
ExecutionConstant pressure boosting sets with one pump and VARIOMAT 2 frequency converter
Ball valve and non return valve on suction side, ball valve and pressure gauge on delivery side
Suitable for installation of a 8-lt cylindrical pressure vessel on delivery side
VARIOMAT 2 device:
Frequency converter installed directly on the pump delivery pipe and water cooled.
Only two parameters to set at starting:
- Working frequency
- Working pressure
Possibility to display:
- Pressure of the system
- Working frequency
- Absorbed current
- Alarms
OperationCONSTANT PRESSURE MODE:
the system keeps the pressure constant when the quantity of water requested by the user changes.
According to the water consumption, the pump at variable speed ensures the required water quantity at the set pressure
ApplicationsFor drawing water out of a well
As pressure boosting pump for central water systems with low pressure (follow local specifications if increasing network pressure)
Motors2-pole induction motors, 50Hz, n 2900 rpm, suitable for operation with frequency converter
- Three-phase 4000V +/-10%
Class F insulation
IP 54 protection
Execution according IEC 60034
Other voltages on demand
Pressure vessels (on demand)Cylindrical with capactiy 8 liters, membrane type, air precharged
48
-
500
0 1 2 3 4 50 20 40 60 80
20
30
40
50
60
70
1050
100
150
ft
5 10 15Imp. g.p.m.0
200
Hm
m /hl/min
3
Q
205/A
206/A1MXH 2
1MXH 8
1MXH 4
204/A
203E
0 2 4 6 80 50 100
20
30
40
50
60
70
10
0 10
50
100
150
ft
20Imp. g.p.m.
Hm
m /hl/minQ
405/A
406
404/A
403/A
3
200
0 140
20
30
40
50
60
10
Imp g.p.m.0
4 6 8 10 1250 100 150 200
20 30 40 50
50
100
150
200
ft
805
804
803
Hm
m /hl/minQ
3
0 280
20
30
40
50
60
10
Imp g.p.m.0
8 12 16 20 24100 200 300 400
40 60 80 100
50
100
150
200
ft
1603
1MXH 16
1602
Hm
m /hl/minQ
3
G 1 1/4
G 1 1/4
G 1 1/2
G 2
G 1
G 1
G 1
G 1 1/2
722
722
722
715
127
127
127
117
548
548
548
537
28
28
31
31
260
260
260
260
210
210
210
210
545565590675545565615675675705735746746
305330355375305330375375350380410410410
m
kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
3 ~Alimentazione:P2 mm
A
400 V 3 ~Motore: 400 V
1MXH 203E-VTT21MXH 204/A-VTT21MXH 205/A-VTT21MXH 206/A-VTT21MXH 403/A-VTT21MXH 404/A-VTT21MXH 405/A-VTT21MXH 406-VTT21MXH 803-VTT21MXH 804-VTT21MXH 805-VTT21MXH 1602-VTT21MXH 1603-VTT2
0,450,550,751,1
0,550,751,11,51,11,51,81,51,8
0,60,75
11,5
0,751
1,52
1,52
2,52
2,5
1,41,6 2
2,71,62
2,73,72,93,74,33,74,3
1 MXH. VTT21 MXH. VTT2 Pressure boosting sets with one horizontal multi-stagepump with VARIOMAT 2 frequency converterCoverage chart
Characteristic and dimensions
4.93.545B2
h1
m1L2
L1
B
h2
PRESSURE SET POINT PRESSURE RESTART PRESSURECURRENT
A bar bar bar
Serial Number
P529
VARIOMAT 2 - 9TTIN: 3 ~ 400V 50/60 HzOUT: 3 ~ 400V 50/60 Hz max 9ATmax: 60C IP65 Pmax 12 bar
made in italy
P530
P531
Mains: 3~ 400VMotor: 3~ 400V
-
501
G 1
G 1 1/4
G 1 1/2
G 1
G 1 1/4
G 1 1/2
590
585
595
75
75
80
440
460
465
716
761
825
265
295
345
150
150
150
225
225
225
260
260
260
1MXV-B 25-2 1MXV-B 32-4
1MXV-B 40-8
H
Q
4
5
6
7
8
10
3
H
Q
4
5
6
7
8
10
3
H
Q
4
5
6
3
kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
3 ~Alimentazione:P2 mm
A
400 V 3 ~Motore: 400 V
1MXV-B 25-204-VTT21MXV-B 25-205-VTT21MXV-B 25-206-VTT21MXV-B 25-207-VTT21MXV-B 25-208-VTT21MXV-B 25-210-VTT21MXV-B 32-404-VTT21MXV-B 32-405-VTT21MXV-B 32-406-VTT21MXV-B 32-407-VTT21MXV-B 32-408-VTT21MXV-B 32-410-VTT21MXV-B 40-804-VTT21MXV-B 40-805-VTT21MXV-B 40-806-VTT2
0,750,751,11,11,51,51,11,11,51,52,22,21,52,22,2
11
1,51,522
1,51,52233233
2,32,32,92,94,34,32,92,94,34,35,35,34,35,35,3
0 5 0
0
0
20
40
60
80
100
120
1 2 3 4 0
100
200
300
5 10 15 Imp. g.p.m.
ft m
20 40 60 80 30 50 70 m /h l/min
0 9 0
0
0
20
40
60
80
100
120
0
100
200
300
ft m
2 3 4 5 6 7 8 50 100 150
10 20 30 Imp. g.p.m.
m /h l/min
0 14 0
0
0
20
40
60
80
100
0
100
200
300
ft
m
2 4 6 8 10 12
10 20 30 40 50 Imp. g.p.m.
50 100 150 200 m /h l/min
Coverage chart
Characteristic and dimensions
1 MXVB. VTT21 MXVB. VTT2 Pressure boosting sets with one vertical multi-stagepump with VARIOMAT 2 frequency converter
h1h2
m1
L2
4.93
.546
L1H
B
B2
PRESSURE SET POINT PRESSURE RESTART PRESSURECURRENT
A bar bar bar
Serial Number
P529
VARIOMAT 2 - 9TTIN: 3 ~ 400V 50/60 HzOUT: 3 ~ 400V 50/60 Hz max 9ATmax: 60C IP65 Pmax 12 bar
made in italy
P530
P531
48
Mains: 3~ 400VMotor: 3~ 400V
-
502
2MXH.VTT2,2MXH.VTT2, 2MXVB.VTT22MXVB.VTT2Constant pressure boosting sets with VARIOMAT 2 frequency converter
ExecutionConstant pressure boosting sets with VARIOMAT 2 frequency converter made of two pumps, ball valve and non return valve on suction side, ball
valve and pressure gauge on delivery side.
Suction and delivery manifolds in stainless steel AISI 304.
Suitable for installation of a 8-lt cylindrical pressure vessel on delivery side.
VARIOMAT 2 device:
Frequency converter installed directly on the pump delivery pipe and water cooled.
Only two parameters to set at starting:
- Working frequency
- Working pressure
Possibility to display:
- Pressure of the system
- Working frequency
- Absorbed current
- Alarms
OperationAccording to the water consumption, one or more pumps starts, all at variable speed, to ensure the required water quantity at the set pressure.
CONSTANT PRESSURE MODE:
the system keeps the pressure constant when the quantity of water requested by the user changes.
ApplicationsFor drawing water out of a well
As pressure boosting pump for central water systems with low pressure (follow local specifications if increasing network pressure).
Motors2-pole induction motors, 50Hz, n 2900 rpm, suitable for operation with frequency converter
- Three-phase 400V +/-10%
Class F insulation
IP 54 protection
Execution according IEC 60034
Other voltages on demand
Pressure vessels (on demand)Cylindrical with capactiy 8 liters, membrane type, air precharged
-
503
0 2 4 6 8 100 40 80 120 160
20
30
40
50
60
70
1050
100
150
ft
10 20 30Imp. g.p.m.0
200
Hm
m /hl/min
3
Q
5
6
2MXH 2
2MXH 8
2MXH 4
2MXH 4
4
3
0 4 8 12 160 100 200
20
30
40
50
60
70
10
0 20
50
100
150
ft
40Imp. g.p.m.
Hm
m /hl/minQ
6
5
4
3
3
200
0 280
20
30
40
50
60
10
Imp g.p.m.0
8 12 16 20 2450 200 300 400
40 60 80 100
50
100
150
200
ft
5
4
3
Hm
m /hl/minQ
3
0 560
20
30
40
50
60
10
Imp g.p.m.0
16 24 32 40 48100 400 600 800
80 120 160 200
50
100
150
200
ft
3
2MXH 16
2
Hm
m /hl/minQ
3
G 2
G 2
G 2 1/2
G 3
G 1 1/2
G 1 1/2
G 2
G 2 1/2
858
858
864
830
162
162
162
152
557
557
563
679
234
234
234
234
600
600
600
600
625
625
625
625
570620645665595620645725750780810830830
330355380405330355380405430460490495495
kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
3 ~Alimentazione:P2 mm
A
400 V 3 ~Motore: 400 V
2MXH 203E-VTT22MXH 204/A-VTT22MXH 205/A-VTT22MXH 206/A-VTT22MXH 403/A-VTT22MXH 404/A-VTT22MXH 405/A-VTT22MXH 406-VTT22MXH 803-VTT22MXH 804-VTT22MXH 805-VTT22MXH 1602-VTT22MXH 1603-VTT2
2 x 0,452 x 0,552 x 0,752 x 1,1
2 x 0,552 x 0,752 x 1,12 x 1,52 x 1,12 x 1,52 x 1,82 x 1,52 x 1,8
2 x 0,62 x 0,75
2 x 12 x 1,5
2 x 0,752 x 1
2 x 1,52 x 2
2 x 1,52 x 2
2 x 2,52 x 2
2 x 2,5
2 x 1,42 x 1,6 2 x 2
2 x 2,72 x 1,62 x 2
2 x 2,72 x 3,72 x 2,92 x 3,72 x 4,32 x 3,72 x 4,3
m
Coverage chart
Characteristic and dimensions
2 MXH. VTT22 MXH. VTT2 Pressure boosting sets with two horizontal multi-stagepumps with VARIOMAT 2 frequency converter
h2H
h1
B2
Bm1
L2
L1
4.93.547
PRESSURE SET POINT PRESSURE RESTART PRESSURECURRENT
A bar bar bar
Serial Number
P529
VARIOMAT 2 - 9TTIN: 3 ~ 400V 50/60 HzOUT: 3 ~ 400V 50/60 Hz max 9ATmax: 60C IP65 Pmax 12 bar
made in italy
P530
P531
PRESSURE SET POINT PRESSURE RESTART PRESSURECURRENT
A bar bar bar
Serial Number
P529
VARIOMAT 2 - 9TTIN: 3 ~ 400V 50/60 HzOUT: 3 ~ 400V 50/60 Hz max 9ATmax: 60C IP65 Pmax 12 bar
made in italy
P530
P531
48
Mains: 3~ 400VMotor: 3~ 400V
-
504
G 1 1/2
G 2
G 2 1/2
G 1 1/2
G 2
G 2 1/2
850
850
850
119
119
124
740
740
740
674
644
709
315
345
425
365
365
365
600
600
600
625
625
625
H
Q
4 5 6 7 8
10
2MXV-B 25-2
3
H
Q
4 5 6 7 8
10
2MXV-B 32-4
3
H
Q
4
5
6
2MXV-B 40-8
3
kW HP H h1DN1 DN2 h2 L1 L2 m1 B B2
3 ~Alimentazione:P2 mm
A
400 V 3 ~Motore: 400 V
2MXV-B 25-204-VTT22MXV-B 25-205-VTT22MXV-B 25-206-VTT22MXV-B 25-207-VTT22MXV-B 25-208-VTT22MXV-B 25-210-VTT22MXV-B 32-404-VTT22MXV-B 32-405-VTT22MXV-B 32-406-VTT22MXV-B 32-407-VTT22MXV-B 32-408-VTT22MXV-B 32-410-VTT22MXV-B 40-804-VTT22MXV-B 40-805-VTT22MXV-B 40-806-VTT2
2 x 0,752 x 0,752 x 1,12 x 1,12 x 1,52 x 1,52 x 1,12 x 1,12 x 1,52 x 1,52 x 2,22 x 2,22 x 1,52 x 2,22 x 2,2
2 x 12 x 1
2 x 1,52 x 1,52 x 22 x 2
2 x 1,52 x 1,52 x 22 x 22 x 32 x 32 x 22 x 32 x 3
2 x 2,32 x 2,32 x 2,92 x 2,92 x 4,32 x 4,32 x 2,92 x 2,92 x 4,32 x 4,32 x 5,32 x 5,32 x 4,32 x 5,32 x 5,3
0 10 0
0
0
20
40
60
80
100
120
2 4 6 8 0
100
200
300
10 20 30 Imp. g.p.m.
ft m
40 80 120 160 60 100 140 m /h l/min
0 18 0
0
0
20
40
60
80
100
120
0
100
200
300
ft m
4 6 8 10 12 14 16 100 200 300
30 40 60 Imp. g.p.m.
m /h l/min
0 28 0
0
0
20
40
60
80
100
0
100
200
300
ft
m
4 8 12 16 20 24
20 40 60 80 100 Imp. g.p.m.
100 200 300 400 m /h l/min
Coverage chart
Characteristic and dimensions
2 MXVB. VTT22 MXVB. VTT2 Pressure boosting sets with two vertical multi-stagepumps with VARIOMAT 2 frequency converter
h1h2
DN2
DN1
4.93.548
L1H
B
B2
m1
L2
PRESSURE SET POINT PRESSURE RESTART PRESSURECURRENT
A bar bar bar
Serial Number
P529
VARIOMAT 2 - 9TTIN: 3 ~ 400V 50/60 HzOUT: 3 ~ 400V 50/60 Hz max 9ATmax: 60C IP65 Pmax 12 bar
made in italy
P530
P531
PRESSURE SET POINT PRESSURE RESTART PRESSURECURRENT
A bar bar bar
Serial Number
P529
VARIOMAT 2 - 9TTIN: 3 ~ 400V 50/60 HzOUT: 3 ~ 400V 50/60 Hz max 9ATmax: 60C IP65 Pmax 12 bar
made in italy
P530
P531
Mains: 3~ 400VMotor: 3~ 400V
-
505
2 MX..,2 MX.., 2 NM, 2 NMD, 2 NG..2 NM, 2 NMD, 2 NG..Pressure boosting sets for domestic use with two electric pumpsFixed speed pump or Variable speed pump (frequency converter)
ConstructionAutomatic pressure boosting plant consisting of two pumps complete with ball, non return valve on the suction side and ball valves on the dischargeside.Suction and delivery manifolds are in AISI 304 stainless steel.Connections are located on the delivery manifold for the installation of two 20 litres cylindrical vessels.
Electrical control boards:- with microprocessor for fixed speed pump units (see page 474).- with frequency converter for variable speed pump units (see page 475).
The unit includes one pressure gauge and two adjustable differential pressure switches or pressure transducer (for sets with frequency converter).
OperationBS 2F Fixed speed pump
Depending on the reduction of the pressure in the system, the pressure switches determine the starting up of the pumps in sequence and themicroprocessor alternates the starts.
BS1V1F Pumps at variable speed with one frequency converter
According to the water consumption, one or more pumps start, one at variable speed and the others at fixed speed, to grant the water
quantity required at the set pressure.
BS2V Pumps at variable speed with two frequency converterDepending on water consumption, one or more pumps are activated, all at variable speed, in order to guarantee the quantity of water requi-red at the set pressure.
ApplicationsFor drawing water out a well.As pressure boosting pump to increase water pressure when needed (follow local rules).
Motors2-pole induction motors, 50 Hz, n 2900 rpm.- Three-phase 230/400V 10% up to 3 kW, suitable for operation with frequency converter;
400/690V 10% for 4 kW, suitable for operation with frequency converter;- Single-phase 230 V 10%, with thermal protector.Insulation class F.Protection IP 54.Constructed in accordance with: IEC 60034.Other voltages and frequencies on request.
Vessels (on request)Cylindrical with capacity 20 litres, membrane type, air precharged.
48
-
506
2 MGP2 MGP Systems with two Multi-Stage stainless steel pumpsFixed speed pump or Variable speed pump (frequency converter)
MGP 404Hm
m /hl/minQ
3
MGP 203
MGP 403Hm
m /hl/minQ
3
Hm
m /hl/min
3
Q
MGP 204Hm
m /hl/min
3
Q
72.1145.2
72.1145.4
0 4 8 12 160 100 200
20
30
40
50
10
0
0 20
50
100
150
ft
40Imp. g.p.m.
0
0 20 40 60U.S. g.p.m.
0 2 4 6 8 100 40 80 120 160
20
30
40
50
10
0
50
0
100
150
ft
10 20 30 40Imp. g.p.m.0
72.1145.1
72.1145.3
0 4 8 12 160 100 200
20
30
40
50
10
0
0 20
50
100
150
ft
40Imp. g.p.m.
0
0 20 40 60U.S. g.p.m.
U.S. g.p.m.0 20 30 40
0 2 4 6 8 100 40 80 120 160
20
30
40
50
10
0
50
0
100
150
ft
10 20 30 40Imp. g.p.m.0
U.S. g.p.m.0 20 30 40
Coverage chart
-
507
2 MGP2 MGP Systems with two Multi-Stage stainless steel pumpsFixed speed pump or Variable speed pump (frequency converter)
Q3~ 1~ max*
Pres. switch setting Manifolds mm
kW HP l/min bar bar DN1 DN2 H h1 h2 L1 L2 m1 B2 B
BS2F 2MGP 203 BSM2F 2MGPM 203 0,45+0,45 0,6+0,6 155 1,42,6 1,02,2 G 2 G 11/2 840 151 206 793 355BS2F 2MGP 204 BSM2F 2MGPM 204 0,55+0,55 0,75+0,75 160 2,03,2 1,52,7 G 2 G 11/2 840 151 206 793 355BS2F 2MGP 403 BSM2F 2MGPM 403 0,55+0,55 0,75+0,75 230 1,22,4 0,92,1 G 2 G 11/2 840 151 206 793 355
235 625 600
BS2F 2MGP 404 BSM2F 2MGPM 404 0,75+0,75 1+1 220 2,43,6 2,03,2 G 2 G 11/2 840 151 206 793 355
DN 2
DN 1
L2
B
L1
m1
h1
h2
H
B2
4.93.315
Characteristic, dimensions and weights
* Maximum pumps flow at minimum set pressure of 2nd pressure switch.
Weightkg
41
46
46
48
Mem.litre
24x2
24x2
24x2
80
Vessellitre
100
100
100
200
Vessel
3~ 1~ Manifolds mm
kW HP DN1 DN2 H h1 h2 L1 L2 m1 B2 B
BS1V1F 2MGP 203 BSM1V1F 2MGP 203 0,45+0,45 0,6+0,6 G 2 G 11/2 1100 151 206 793 355BS1V1F 2MGP 204 BSM1V1F 2MGP 204 0,55+0,55 0,75+0,75 G 2 G 11/2 1100 151 206 793 355BS1V1F 2MGP 403 BSM1V1F 2MGP 403 0,55+0,55 0,75+0,75 G 2 G 11/2 1100 151 206 793 355
235 625 600
BS1V1F 2MGP 404 BSM1V1F 2MGP 404 0,75+0,75 1+1 G 2 G 11/2 1100 151 206 793 355
Weightkg
41
46
46
48
Membranelitre
24x2
24x2
24x2
24x2
Vessel
3~ 1~ Manifolds mm
kW HP DN1 DN2 H h1 h2 L1 L2 m1 B2 B
BS2V 2MGP 203 BSM2V 2MGP 203 0,45+0,45 0,6+0,6 G 2 G 11/2 1100 151 206 793 355BS2V 2MGP 204 BSM2V 2MGP 204 0,55+0,55 0,75+0,75 G 2 G 11/2 1100 151 206 793 355BS2V 2MGP 403 BSM2V 2MGP 403 0,55+0,55 0,75+0,75 G 2 G 11/2 1100 151 206 793 355
235 625 600
BS2V 2MGP 404 BSM2V 2MGP 404 0,75+0,75 1+1 G 2 G 11/2 1100 151 206 793 355
Weightkg
41
46
46
48
Membranelitre
24x2
24x2
24x2
24x2
Vessel
BS2F BSM2F
BS1V1F BSM1V1F
BS2V BSM2V
48
Mains: 230V 1~Motor: 230V 3~ and 230V 1~
Mains: 400V 3~Motor: 400V 3~
Mains: 230V 1~Motor: 230V 3~
Mains: 400V 3~Motor: 400V 3~
Mains: 230V 1~Motor: 230V 1~
Mains: 400V 3~Motor: 400V 3~
Motor
Motor
Motor
-
508
2 MXP2 MXP Systems with two Multi-Stage stainless steel pumpsFixed speed pump or Variable speed pump (frequency converter)
MXP 203
MXP 403Hm
m /hl/minQ
3
Hm
m /hl/min
3
Q
MXP 204
MXP 404Hm
m /hl/minQ
3
Hm
m /hl/min
3
Q
0 2 4 6 8 100 40 80 120 160
20
30
40
50
10
0
50
0
100
150
ft
10 20 30 40Imp. g.p.m.0
72.1145.1
72.1145.3
0 4 8 12 160 100 200
20
30
40
50
10
0
0 20
50
100
150
ft
40Imp. g.p.m.
0
0 20 40 60U.S. g.p.m.
U.S. g.p.m.0 20 30 40
0 2 4 6 8 100 40 80 120 160
20
30
40
50
10
0
50
0
100
150
ft
10 20 30 40Imp. g.p.m.0
72.1145.2
72.1145.4
0 4 8 12 160 100 200
20
30
40
50
10
0
0 20
50
100
150
ft
40Imp. g.p.m.
0
0 20 40 60U.S. g.p.m.
U.S. g.p.m.0 20 30 40
Coverage chart
-
509
2 MXP2 MXP Systems with two Multi-Stage stainless steel pumpsFixed speed pump or Variable speed pump (frequency converter)
Q3~ 1~ max*
Pres. switch setting Manifolds mm
kW HP l/min bar bar DN1 DN2 H h1 h2 L1 L2 m1 B2 B
BS2F 2MXP 203 BSM2F 2MXPM 203 0,45+0,45 0,6+0,6 155 1,42,6 1,02,2 G 2 G 11/2 840 151 206 793 355BS2F 2MXP 204/A BSM2F 2MXPM 204/A 0,55+0,55 0,75+0,75 160 2,03,2 1,52,7 G 2 G 11/2 840 151 206 793 355BS2F 2MXP 403/A BSM2F 2MXPM 403/A 0,55+0,55 0,75+0,75 230 1,52,7 1,22,4 G 2 G 11/2 840 151 206 793 355
235 625 600
BS2F 2MXP 404/A BSM2F 2MXPM 404/A 0,75+0,75 1+1 220 2,43,6 2,03,2 G 2 G 11/2 840 151 206 793 355
DN 2
DN 1
L2
B
L1
m1
h1
h2
H
B2
4.93.315
Characteristic, dimensions and weights
* Maximum pumps flow at minimum set pressure of 2nd pressure switch.
Weightkg
41
46
46
48
Mem.litre
24x2
24x2
24x2
80
Vessellitre
100
100
100
200
Vessel
3~ 1~ Manifolds mm
kW HP DN1 DN2 H h1 h2 L1 L2 m1 B2 B
BS1V1F 2MXP 203 BSM1V1F 2MXP 203 0,45+0,45 0,6+0,6 G 2 G 11/2 1100 151 206 793 355BS1V1F 2MXP 204/A BSM1V1F 2MXP 204/A 0,55+0,55 0,75+0,75 G 2 G 11/2 1100 151 206 793 355BS1V1F 2MXP 403/A BSM1V1F 2MXP 403/A 0,55+0,55 0,75+0,75 G 2 G 11/2 1100 151 206 793 355
235 625 600
BS1V1F 2MXP 404/A BSM1V1F 2MXP 404/A 0,75+0,75 1+1 G 2 G 11/2 1100 151 206 793 355
Weightkg
41
46
46
48
Membranelitre
24x2
24x2
24x2
24x2
Vessel
3~ 1~ Manifolds mm
kW HP DN1 DN2 H h1 h2 L1 L2 m1 B2 B
BS2V 2MXP 203 BSM2V 2MXP 203 0,45+0,45 0,6+0,6 G 2 G 11/2 1100 151 206 793 355BS2V 2MXP 204/A BSM2V 2MXP 204/A 0,55+0,55 0,75+0,75 G 2 G 11/2 1100 151 206 793 355BS2V 2MXP 403/A BSM2V 2MXP 403/A 0,55+0,55 0,75+0,75 G 2 G 11/2 1100 151 206 793 355
235 625 600
BS2V 2MXP 404/A BSM2V 2MXP 404/A 0,75+0,75 1+1 G 2 G 11/2 1100 151 206 793 355
Weightkg
41
46
46
48
Membranelitre
24x2
24x2
24x2
24x2
Vessel
BS2F BSM2F
BS1V1F BSM1V1F
BS2V BSM2V
48
Mains: 230V 1~Motor: 230V 3~ and 230V 1~
Mains: 400V 3~Motor: 400V 3~
Mains: 230V 1~Motor: 230V 3~
Mains: 400V 3~Motor: 400V 3~
Mains: 230V 1~Motor: 230V 1~
Mains: 400V 3~Motor: 400V 3~
Motor
Motor
Motor
-
510
2 NM, NMD2 NM, NMD Systems with two Centrifugal PumpsFixed speed pump or Variable speed pump (frequency converter)
NMD 20/110B/A NMD 20/110A/A
NMD 20/140BE
NMD 20/140AE
NM 2/A/A
NM 3/CE
NM 3/BE NM 3/A/A
1
U.S. g.p.m.
Imp. g.p.m.
l/minm /h 8
16
m
36
100
ft
10050
20
20
30
765432
10 20
3010
60
80
1
U.S. g.p.m.
Imp. g.p.m.
l/minm /h 9
24
m
44
100ft
10050
30
40
20
10
876543150
20 30
30
80
120
140
1
U.S. g.p.m.
Imp. g.p.m.
l/minm /h 10
36
m
56
ft
10050
40
50
10
150
120
140
160
180
9876543
20 30
20 30 40
U.S. g.p.m.
Imp. g.p.m.
m
68
ft
50
60
10
140
160
20
200
22020 30 40
30 40
Q
HH
Q
H H
Q
H H
H H
3
72.955.1C
3
72.955.2C
3
72.955.4C
1
U.S. g.p.m.
Imp. g.p.m.
l/minm /h 12
100 200
20
m
35
100
ft25
30
3 4 5 6 7 8 9 10 1115050
80
70
110
20 30 40 50
20 30 40
1
U.S. g.p.m.
Imp. g.p.m.
l/minm /h 12
100 200
27
m
40
100
ft
30
35
3 4 5 6 7 8 9 10 1115050
20 30 40 50
20 30 40
90
120
130
42
1
U.S. g.p.m.
Imp. g.p.m.
l/minm /h
150 300
36
m
60
ft
250
30
30
40
50
4 6 8 10 12 14 16 18200100
120
20 40 50 60
20 40 50 60 70
140
180
1
U.S. g.p.m.
Imp. g.p.m.
l/minm /h
150 300
26
m
50
100
ft
250
30
30
30
40
4 6 8 10 12 14 16 18200100
150
20 40 50 60
20 40 50 60 70
1 ~
3 ~
1 ~
3 ~
Q
H H
Q
H H
Q
H
H
Q
HH
72.955.3C
72.955.6C
72.955.8C72 955.7C
3
3
3
3
1l/minm /h 11
42
10050 150109876543Q 3
72.955.5C
Coverage chart
-
511
2 NM, NMD2 NM, NMD Systems with two Centrifugal PumpsFixed speed pump or Variable speed pump (frequency converter)
Q3~ 1~ max*
Pres. switch setting Manifolds mm
kW HP l/min bar bar DN1 DN2 H h1 h2 L1 L2 m1 B2 B
BS2F 2NMD 20/110B/A BSM2F 2NMDM 20/110B/A 0,45+0,45 0,6+0,6 120 2,03,0 1,72,7 G2 G 11/2 840 129 277 670 315BS2F 2NMD 20/110A/A BSM2F 2NMDM 20/110A/A 0,75+0,75 1+1 130 2,84,0 2,43,6 G2 G 11/2 840 129 277 670 315BS2F 2NM 2/A/A BSM2F 2NMM 2/A/A 0,75+0,75 1+1 200 2,03,0 1,72,7 G2 G 11/2 840 129 295 620 262BS2F 2NMD 20/140BE BSM2F 2NMDM 20/140BE 1,1+1,1 1,5+1,5 160 3,44,9 3,24,7 G2 G 11/2 840 146 295 670 320
BSM2F 2NMDM 20/140AE 1,5+1,5 2+2 160 4,05,3 3,75,0 G2 G 11/2 840 146 295 670 320 235 625 600BS2F 2NMD 20/140AE 1,5+1,5 2+2 180 5,06,3 4,76,0 G2 G 11/2 840 146 295 670 320BS2F 2NM 3/CE BSM2F 2NMM 3/CE 1,1+1,1 1,5+1,5 200 2,53,5 2,23,2 G2 G 11/2 840 146 325 650 267
BSM2F 2NMM 3/BE 1,5+1,5 2+2 200 3,04,0 2,73,7 G2 G 11/2 840 146 325 650 267BS2F 2NM 3/BE 1,5+1,5 2+2 270 3,24,5 2,94,2 G2 G 11/2 840 146 325 650 267BS2F 2NM 3/A/A 2,2+2,2 3+3 280 4,05,3 3,75,0 G2 G 11/2 840 146 325 650 267
DN 1
DN 2
m1
h1
h2
H
B2
L2
B
L1
3.93.042
Characteristic, dimensions and weights
* Maximum pumps flow at minimum set pressure of 2nd pressure switch.
48
Weightkg
51
55
54
72
75
77
71
75
76
78
Mem.litre
24x2
60
80
80
100
100
100
100
100
200
Vessellitre
100
100
200
200
200
200
200
300
300
300
Vessel
3~ 1~ Manifolds mm
kW HP DN1 DN2 H h1 h2 L1 L2 m1 B2 B
BS1V1F 2NMD 20/110B/A BSM1V1F 2NMD 20/110B/A 0,45+0,45 0,6+0,6 G2 G 11/2 840 129 277 670 315BS1V1F 2NMD 20/110A/A BSM1V1F 2NMD 20/110A/A 0,75+0,75 1+1 G2 G 11/2 840 129 277 670 315BS1V1F 2NM 2/A/A BSM1V1F 2NM 2/A/A 0,75+0,75 1+1 G2 G 11/2 840 129 295 620 262BS1V1F 2NMD