SALTEK, s.r.o. (limited liability company), is a Czech company specialising in the develop-ment and manufacture of surge protection devices (SPD). SALTEK offer a wide range of li-ghtning current arresters and surge arresters type 1 to 3, pursuant to EN 61643-11, as well as surge arresters for information technolo-gy, measurement and control, telecommuni-cations, also for the protection of photovol-taic applications.SALTEK has been in the business since 1995. Currently, the company has 2 centres in the Czech Republic.. Its headquarters, manage-ment, R+D, manufacturing premises, test lab and logistics are based in Ústí nad Labem. The Export subsidiary SALTEK TRADE and techni-cal support is situated in Prague.Our in-house product development is crucial for the dynamic growth and advancement of the company. The design office and laboratories are equipped with unique instruments and technologies. State-of-the-art materials, design procedures, technologies and measure-
ment methods are used for this development.Exceptional attention is paid to product quality. From the in-coming material and component testing, through multiple checks during manufacturing, up to robotised output control. Shortly after it was established, SALTEK introduced and then certified its management system in compliance with internati-onal standards. In 2005 the company introduced an integrated IMS management system, which consists of a quali-ty management system under ISO 9001, an envi-ronmental protection ma-nagement system under ISO 14001 and a health and safety management
system under OHSAS 18001. The IMS system is perio-dically reviewed by an external auditing company TÜV NORD Czech. In 2010, to handle the rapid growth of the company SALTEK adopted an information system SAP enabling smart control over all its processes.
SPD type 1 and 2 FLP-B+C MAXI VSPowerful combined lightning and surge arrestermodern technology – no follow current, no leakage current
T1 T2
SPD type 1 and 2 FLP-12,5 VEconomical lightning and surge arresters FLP-275 Vbased on MOV technology
T1 T2
SPD type 2 SLP-275 VVersatile standard product with excelent reliabilityVariety of voltages
T2
SPD type 2 SLP-275 VBEnhanced MOV-GDT combination reducing leakage currentwith prolonged MOV lifetime, T3 tested
T2
SPD type 3 DA-275 VTerminal protection for DIN rail DA-275 DJ
T3
SPD type 3 CZ-275 ATerminal protection
T3
SPD type 1 FLP-SG50 V SLightning current arresters based on spark-gap technology FLP-A50N VS FLP-A100N VS
T1
The complete range of devices for low voltage power supply, signal, measurement, data and telecom lines also for photovoltaic applications is available on
www.saltek.eu
CATALOGUE
SURGE PROTECTIONLOW VOLTAGE
1. Introduction – Legislative
The use of modern sophisticated equipment, consumer electronics and control systems places high demands on their electromagnetic compatibility. Modern electronic control systems provided with circuits with a very high integration level are becoming more and more sensitive to electromagnetic disturbance and overvoltage. The installation of surge protections according to effective legal standards will reduce the danger of their being damaged to a minimum. Technical designs are defined by standards harmonised with EU standards:
a) Protective bonding to the same potential including the conductor cross section for the main and additional bonding is defined by standards EN 50310 ed. 2. , IEC 60364-5-54, IEC 60364-4-41
b) Lightning protection is specified in the EN 62305 collection of new standards, harmonised with European standards. EN 62305 – Part 1 deals with general principles.
Lightning protection level
Maximum lightning
parameter according to LPL
LPL First short discharge
LPL I 200 kA
LPL II 150 kALPL III 100 kALPL IV 100 kA
EN 62305 – Part 2 – deals with the risk assessment for buildings or engineering networks struck by lightning.
EN 62305 – Part 3 – deals with the proposal for external lightning protection (lightning conductor).
EN 62305 – Part 4 – deals with protective measures resulting in the reduction of failures of electrical and electronic systems inside the building (zone protection)
c) Classification of protections is set forth in standard EN 61643-11.Devices are classified into three basic categories:SPD type 1 – lightning current arrestersSPD type 2 – surge arrestersSPD type 3 – surge arresters
d) Classification of low-voltage distribution into impulse resistance categories, including specification of the maximum allowed overvoltage is determined in standard EN 60664-1
Lightning and surge protection
Rated impulse for equipment (acc. to EN 60664-1) or Impulse-withstand voltage.
Lightning protection zones
The standard EN 62305-4 defines lightning protection zones LPZ in view of the direct and indirect (electromagnetic pulse – LEMP) lightning effect:
LPZ 0A – free area (possibility of a direct lightning strike, non-attenuated LEMP)
LPZ 0B – lightning conductor receiver protection area (direct lightning strike protection, non-attenuated LEMP)
LPZ 1 – inside a building (direct lightning strike is eliminated, attenuated LEMP – depending upon shielding)
LPZ 2 – inside a room – e.g. a server room with a conductive floor, FeAl floors and wall lining (further attenuation of LEMP in connection with a higher shielding level)
LPZ 3 – inside a metal box (e.g. 19“ RACK)
Lightning and surge protection
Example of main and additional bonding
telephone cable
gas pipeline
water pipeline
base ground
main protective bonding bar
2
Insulation coordination
liftflats appliance
appliances
Lightning and surge protection
2. Connection of protections in TN, TT and IT systems
SPD connection in TN-C system SPD connection in TN-S system SPD connection in TT system SPD connection in IT system
Principle of connection of surge protections in TN systemsSPD type 1 SPD type 2 SPD type 3
3. Principles of positioning and wiring of surge arresters and lightning current arresters
Surge arresters and lightning current arresters cannot be installed in the distribution system at random. You must be aware of the fact that protection should be placed at the closest proximity to the input feed cable in order to minimize the inductive loop area, see fig. 1.
Fig. 1 – Examples of device positioning in the distribution system.
overhead, PEN (PE) down overhead, PEN (PE) up underground, PEN (PE) down underground, PEN (PE) up
Another important condition for the wiring of arresters is to minimize the impedance of interconnecting conductors. Furthermore, the length of theinterconnecting conductors must be as short as possible (the total length of interconnecting conductors must not exceed 1 m). The cross section of theinterconnecting conductors should be as large as possible – up to the maximum cross section available for the terminal type.The cross section of interconnecting conductors is recommended to be larger by at least one cable size than the PEN (PE) conductor diameter (e.g.if the PEN conductor diameter is 10 mm2, the cross section of the interconnecting conductor should be 16 mm2).If arresters are placed in a circuit fitted with residual current devices (RCD), the arrester must be installed before the RCD (not in the RCD circuit) to avoidspontaneous RCD tripping due to surge arresters or lightning current arresters.If the RCD is placed before the protection, it is necessary to use the delayed RCD type, e.g. S-type or G-type.
3
FLP-SG50 VFLP-SG50 VS
SPD type 1 – lightning current arresterEncapsulated high-performance spark gap with replaceable module, visual fault signalling
To be installed in low-voltage distributions at the boundary of LPZ 0A and LPZ 1 zones to prevent overvoltage effects induced during direct or indirect lightning strikes in the most demanding applications in the heavy and chemicals industry, power stations, etc.Remote status signalling (S).
Dimension drawing Basic circuit diagram
connection of signalization
terminal3666
4590
9
15
Lightning Current Arresters
4
Technical data FLP-SG50 VS
Nominal voltage Un 230 V ACMaximum operating voltage Uc 255 V ACNominal discharge current (8/20 μs) In 50 kALightning impulse current (10/350 μs) Iimp 50 kAVoltage protection level Up <2,5 kV
Response time ta 100 nsAbility to independently switch off the following current Ifi 50 kANominal short circuit current ISCCR 50 kArms
Maximum overcurrent protection 315 A gL/gGMaximum overcurrent protection for serial connection 125 A gL/gGTOV voltage UT 335 V/5 sec.Degree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 2,5/50 mm2 ; AWG: 13/1 Stranded min/max ISO: 2,5/35 mm2 ; AWG: 13/2Visual fault indication red indication fieldRemote indication – S design potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard EN 61643-11:2012 Ordering number 8595090540533Ordering number
FLP-SG50 V 8595090540533FLP-SG50 VS 8595090540540
Lightning Current Arresters
SPD type 1 – lightning current arresterN-PE module, replaceable module
To be installed in low-voltage distributions at the boundary of LPZ 0A–LPZ 1 zones and higher to prevent overvoltage effects induced during direct or indirect lightning strikes for the connection of SPD type 1 in the mode 1+1.
Dimension drawing Basic circuit diagram
FLP-A50N VS
Technical data FLP-A50N VS
Nominal voltage Un —Maximum operating voltage Uc 255 V ACNominal discharge current (8/20 μs) In 50 kAMaximum discharge current (8/20 μs) Imax 100 kALightning impulse current (10/350 μs) Iimp 50 kAVoltage protection level Up 1,5 kVResponse time ta 100 nsAbility to independently switch off the following current Ifi 100 AShort-circuit proof at maximum overcurrent protection —Maximum overcurrent protection —Degree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 2,5/50 mm2 ; AWG: 13/1 Stranded min/max ISO: 2,5/35 mm2 ; AWG: 13/2Visual fault indication noRemote indication * potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012 Ordering number 8595090535737Replacement module FLP-A50N V/0 8595090535379
* Remote signalling of N-PE module shows the presence of the replaceable module
90 45
66 36
9
15
N( )
N( )
(N)
(N)
5
Lightning Current Arresters
SPD type 1 – lightning current arresterN-PE module, replaceable module
To be installed in low-voltage distributions at the boundary of LPZ 0A and LPZ 1 zones to prevent overvoltage effects induced during direct or indirect lightning strikes for the connection of SPD type 1 in the mode 3+1.
Dimension drawing Basic circuit diagram
FLP-A100N VS
Technical data FLP-A100N VS
Nominal voltage Un —Maximum operating voltage Uc 255 V ACNominal discharge current (8/20 μs)/pole In 100 kAMaximum discharge current (8/20 μs) Imax 100 kALighting impulse current (10/350 μs)/pole Iimp 100 kAVoltage protection level Up 1,5 kVResponse time ta 100 nsAbility to independently switch off the following current Ifi 100 AShort-circuit proof at maximum overcurrent protection —Maximum overcurrent protection —Degree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected condutors Solid min/max ISO: 2,5/50 mm2 ; AWG: 13/1 Stranded min/max ISO: 2,5/35 mm2 ; AWG: 13/2Visual fault indication noRemote indication * potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012 Ordering number 8595090535744Replacement module FLP-A100N V/0 8595090535362
* Remote signalling of N-PE module shows the presence of the replaceable module
90 45
66 36
9
15
N( )
N( )
(N)
(N)
6
Lightning Current Arresters
FLP-B+C MAXI VFLP-B+C MAXI VS
Dimension drawing Basic circuit diagram
SPD type 1 and type 2versatile single-pole arrester Surge protective devices (SPD) type 1 and type 2 (class B+C) serve for protection of low-voltage(230/400 V AC) networks and connected appliances against surge voltages due to direct or indirectlightning strikes in the concept of zone lightning protection at the boundary of the LPZ 0 and LPZ 1(or higher) zones.Replaceable module offers a combination of heavy duty gas discharge tube (GDT) rated at 25 kA(10/350 μsec pulse) with high energy varistors block. This proven technology guarantee no followcurrent, no leakage current and low residual voltage.Remote status signalling contact – version „S“.
Technical data FLP-B+C MAXI VS
Nominal voltage Un 230 V ACMaximum operating voltage Uc 260 V ACNominal discharge current (8/20 μs) In 30 kAMaximum discharge current (8/20 μs) Imax 60 kALightning impulse current (10/350 μs) Iimp 25 kAVoltage protection level Up 1,5 kV
Response time ta 100 nsAbility to independently switch off the following current Ifi no following currentShort-circuit proof at maximum overcurrent protection 50 kArms
Maximum overcurrent protection 250 A gL/gGMaximum overcurrent protection for serial connection 125 A gL/gGDegree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 2,5/50 mm2 ; AWG : 13/1 Stranded min/max ISO: 2,5/35 mm2 ; AWG: 13/2Visual fault indication red indication fieldRemote indication potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberFLP-B+C MAXI V 8595090550914FLP-B+C MAXI VS 8595090535331
Replacement module FLP-B+C MAXI V/0 8595090535355
connection of signalization
terminal3666
4590
9
15
(L/N)
L/N ( )
L/N( )
(L/N)
7
SPD type 1 and type 22-pole (1+NPE) arrester for single phase TT (TNS) networksTotal Iimp = 50kA (10/350) Surge protective devices (SPD) type 1 and type 2 (class B+C) serve for protection of low-voltage (230/400 V AC) networks and connected appliances against surge voltages due to direct or indirect lightning strikes in the concept of zone lightning protection at the boundary of the LPZ 0 and LPZ 1 (or higher) zones.Replaceable module offers a combination of heavy duty gas discharge tube (GDT) rated at 25 kA (10/350 μsec pulse) with high energy varistors block. This proven technology guarantee no follow current, no leakage current and low residual voltage.Remote status signalling contact – version „S“.
Dimension drawing Basic circuit diagram
Technical data L-N N-PE
Nominal voltage Un 230 V AC —Maximum operating voltage Uc 260 V AC 255 V ACNominal discharge current (8/20 μs) In 30 kA 50 kAMaximum discharge current Imax 60 kA 100 kALighting impulse current Iimp 25 kA 50 kAVoltage protection level Up 1,5 kV 1,5 kVResponse time ta 100 ns 100 nsAbility to independently switch off the following current Ifi no following current 100 AShort-circuit proof at maximum overcurrent protection 50 kArms —Maximum overcurrent protection 250 A gL/gG —Maximum overcurrent protection for serial connection 125 A gL/gG —Degree of protection IP 20 IP 20Range of operating temperatures – 40 °C … + 80 °C – 40 °C … + 80 °CMounting on DIN rail 35 mm DIN rail 35 mmCross-section of connected condutors Solid min/max ISO: 2,5/50 mm2 ; AWG: 13/1 ISO: 2,5/50 mm2 ; AWG: 13/1 Stranded min/max ISO: 2,5/35 mm2 ; AWG: 13/2 ISO: 2,5/35 mm2 ; AWG: 13/2Visual fault indication red indication field noRemote indication* potential-free change-over contact potential-free change-over contact*Remote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DC 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2 max. 1,5 mm2
Meets the requirements of standard EN 61643-11 + A11 EN 61643-11:2012
Ordering numberFLP-B+C MAXI V/1+1 8595090550952FLP-B+C MAXI VS/1+1 8595090537830
Replacement moduleFLP-B+C MAXI V/0 (for L-N) 8595090535355FLP-A50N V/0 (for N-PE) 8595090535379
* Remote signalling of N-PE module shows the presence of the replaceable module
FLP-B+C MAXI V/1+1FLP-B+C MAXI VS/1+1
connection ofsignalization terminal
15
PE PE
7266
4590
9
15
N
LL
N NN
Lightning Current Arresters
8
SPD type 1 and type 22-pole arrester for single phase TNS networksTotal Iimp= 50kA (10/350) Surge protective devices (SPD) type 1 and type 2 (class B+C) serve for protection of low-voltage (230/400 V AC) networks and connected appliances against surge voltages due to direct or indirect lightning strikes in the concept of zone lightning protection at the boundary of the LPZ 0 and LPZ 1 (or higher) zones.Replaceable module offers a combination of heavy duty gas discharge tube (GDT) rated at 25 kA (10/350 μsec pulse) with high energy varistors block. This proven technology guarantee no follow current, no leakage current and low residual voltage.Remote status signalling contact – version „S“.
Dimension drawing Basic circuit diagram
Technical data FLP-B+C MAXI VS/2
Nominal voltage Un 230 V ACMaximum operating voltage Uc 260 V ACNominal discharge current (8/20 μs)/pole In 30 kAMaximum discharge current (8/20 μs)/pole Imax 60 kALightning impulse current (10/350 μs)/pole Iimp 25 kAVoltage protection level Up 1,5 kVResponse time ta 100 nsAbility to independently switch off the following current Ifi no following currentShort-circuit proof at maximum overcurrent protection 50 kArms
Maximum overcurrent protection 250 A gL/gGMaximum overcurrent protection for serial connection 125 A gL/gGDegree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 2,5/50 mm2 ; AWG: 13/1 Stranded min/max ISO: 2,5/35 mm2 ; AWG: 13/2Visual fault indication red indication fieldRemote indication potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberFLP-B+C MAXI V/2 8595090550921FLP-B+C MAXI VS/2 8595090537847
Replacement module FLP-B+C MAXI V/0 8595090535355
FLP-B+C MAXI V/2FLP-B+C MAXI VS/2
connection of signalization terminal
15
7266
4590
9
15
PE
L/N
L/N
L/N
L/N
PE PE PE
Lightning Current Arresters
9
SPD type 1 and type 23-pole arrester for 3-phase TNC networks Total Iimp= 75kA (10/350) Surge protective devices (SPD) type 1 and type 2 (class B+C) serve for protection of low-voltage (230/400 V AC) networks and connected appliances against surge voltages due to direct or indirect lightning strikes in the concept of zone lightning protection at the boundary of the LPZ 0 and LPZ 1 (or higher) zones.Replaceable module offers a combination of heavy duty gas discharge tube (GDT) rated at 25 kA (10/350 μsec pulse) with high energy varistors block. This proven technology guarantee no follow current, no leakage current and low residual voltage.Remote status signalling contact – version „S“.
Technical data FLP-B+C MAXI VS/3
Nominal voltage Un 230 V ACMaximum operating voltage Uc 260 V ACNominal discharge current (8/20 μs)/pole In 30 kAMaximum discharge current (8/20 μs)/pole Imax 60 kALightning impulse current (10/350 μs)/pole Iimp 25 kAVoltage protection level Up 1,5 kVResponse time ta 100 nsAbility to independently switch off the following current Ifi no following currentShort-circuit proof at maximum overcurrent protection 50 kArms
Maximum overcurrent protection 250 A gL/gGMaximum overcurrent protection for serial connection 125 A gL/gGDegree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 2,5/50 mm2 ; AWG: 13/1 Stranded min/max ISO: 2,5/35 mm2 ; AWG: 13/2Visual fault indication red indication fieldRemote indication potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberFLP-B+C MAXI V/3 8595090550938FLP-B+C MAXI VS/3 8595090535706
Replacement module FLP-B+C MAXI V/0 8595090535355
FLP-B+C MAXI V/3FLP-B+C MAXI VS/3
connection of signalization terminal
Dimension drawing Basic circuit diagram
90 45
66 108
9
15
Lightning Current Arresters
10
Lightning Current Arresters
SPD type 1 and type 24-pole arrester for 3-phase TNS networksTotal Iimp= 100kA (10/350) Surge protective devices (SPD) type 1 and type 2 (class B+C) serve for protection of low-voltage (230/400 V AC) networks and connected appliances against surge voltages due to direct or indirect lightning strikes in the concept of zone lightning protection at the boundary of the LPZ 0 and LPZ 1 (or higher) zones.Replaceable module offers a combination of heavy duty gas discharge tube (GDT) rated at 25 kA (10/350 μsec pulse) with high energy varistors block. This proven technology guarantee no follow current, no leakage current and low residual voltage.Remote status signalling contact – version „S“.
Dimension drawing Basic circuit diagram
FLP-B+C MAXI V/4FLP-B+C MAXI VS/4
connection of signalization terminal
Technical dataFLP-B+C MAXI VS/4
Nominal voltage Un 230 V ACMaximum operating voltage Uc 260 V ACNominal discharge current (8/20 μs)/pole In 30 kAMaximum discharge current (8/20 μs)/pole Imax 60 kALighting impulse current (10/350 μs)/pole Iimp 25 kAVoltage protection level Up 1,5 kVResponse time ta 100 nsAbility to independently switch off the following current Ifi no following currentShort-circuit proof at maximum overcurrent protection 50 kArms
Maximum overcurrent protection 250 A gL/gGMaximum overcurrent protection for serial connection 125 A gL/gGDegree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected condutors Solid min/max ISO: 2,5/50 mm2 ; AWG: 13/1 Stranded min/max ISO: 2,5/35 mm2 ; AWG: 13/2Visual fault indication red indication fieldRemote indication potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberFLP-B+C MAXI V/4 8595090550945FLP-B+C MAXI VS/4 8595090535713
Replacement module FLP-B+C MAXI V/0 8595090535355
66
4590
144
9
15
66
4590
144
9
15
11
SPD type 1 and type 24-pole (3+NPE) arrester for 3-phase TT(TNS) networksTotal Iimp= 100kA (10/350) Surge protective devices (SPD) type 1 and type 2 (class B+C) serve for protection of low-voltage (230/400 V AC) networks and connected appliances against surge voltages due to direct or indirect lightning strikes in the concept of zone lightning protection at the boundary of the LPZ 0 and LPZ 1 (or higher) zones.Replaceable module offers a combination of heavy duty gas discharge tube (GDT) rated at 25 kA (10/350 μsec pulse) with high energy varistors block. This proven technology guarantee no follow current, no leakage current and low residual voltage.Remote status signalling contact – version „S“.
Dimension drawing Basic circuit diagram
Technical dataL-N N-PE
Nominal voltage Un 230 V AC —Maximum operating voltage Uc 260 V AC 255 V ACNominal discharge current (8/20 μs)/pole In 30 kA 100 kAMaximum discharge current (8/20 μs) Imax 60 kA 100 kALighting impulse current (10/350 μs)/pole Iimp 25 kA 100 kAVoltage protection level Up 1,5 kVVoltage protection level (L - PE) Up 2,2 kVResponse time ta 100 ns 100 nsAbility to independently switch off the following current Ifi no following current 100 AShort-circuit proof at maximum overcurrent protection 50 kArms —Maximum overcurrent protection 250 A gL/gG —Maximum overcurrent protection for serial connection 125 A gL/gG —Degree of protection IP 20 IP 20Range of operating temperatures – 40 °C … + 80 °C – 40 °C … + 80 °CMounting on DIN rail 35 mm DIN rail 35 mmCross-section of connected condutors Solid min/max ISO: 2,5/50 mm2 ; AWG: 13/1 ISO: 2,5/50 mm2 ; AWG: 13/1 Stranded min/max ISO: 2,5/35 mm2 ; AWG: 13/2 ISO: 2,5/35 mm2 ; AWG: 13/2Visual fault indication red indication field noRemote indication* potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberFLP-B+C MAXI V/3+1 8595090550969FLP-B+C MAXI VS/3+1 8595090535720
Replacement moduleFLP-B+C MAXI VS/0 (for L-N) 8595090535355FLP-A100N V/0 (for N-PE) 8595090535362
* Remote signalling of N-PE module shows the presence of the replaceable module
FLP-B+C MAXI V/3+1FLP-B+C MAXI VS/3+1
connection ofsignalization terminal
Lightning Current Arresters
90 45
66 144
9
15
90 45
66 144
9
15
12
Technical data
Lightning Current Arresters
SPD type 1 and type 2versatile single-pole arrester
Varistor lightning and surge current arrester to be installed in low-voltage distributions at the boundary of LPZ 0–LPZ 1 zones and higher to prevent overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
Dimension drawing Basic circuit diagram
Technical data FLP-12,5 VS
Nominal voltage Un 230 V ACMaximum operating voltage Uc 275 V AC / 350 V DCNominal discharge current (8/20 μs) In 30 kAMaximal discharge current Imax 60 kALightning impulse current (10/350 μs) Iimp 12,5 kAVoltage protection level Up 1,2 kVVoltage protection level @ I = 5 kA (8/20 μs) Up 0,9 kVResponse time ta 25 nsShort-circuit proof at maximum overcurrent protection 50 kArms
Maximum overcurrent protection 160 A gL/gGDegree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication fieldRemote indication – S design potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering number FLP-12,5 V 8595090534211 FLP-12,5 VS 8595090534228
Replacement module FLP-12,5 V/0 8595090534310
FLP-12,5 VFLP-12,5 VS
connection ofsignalization terminal
13
FLP-12,5 V/3
Nominal voltage Un 230 V ACMaximum operating voltage Uc 275 V AC / 350 V DCNominal discharge current (8/20 μs)/pole In 30 kAMaximal discharge current/pole Imax 60 kALightning impulse current (10/350 μs)/pole Iimp 12,5 kAVoltage protection level Up 1,2 kVVoltage protection level @ I = 5 kA (8/20 μs) Up 0,9 kVResponse time ta 25 nsShort-circuit proof at maximum overcurrent protection 50 kArms
Maximum overcurrent protection 160 A gL/gGDegree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication fieldRemote indication – S design potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberFLP-12,5 V/3 8595090534259FLP-12,5 V/3S 8595090534266
Replacement module FLP-12,5 V/0 8595090534310
Lightning Current Arresters
SPD type 1 and type 23-pole arrester for 3-phase TNC networksTotal Iimp= 37,5kA (10/350)
Varistor lightning and surge current arresters to be installed in low-voltage distributions at the boundary of LPZ 0–LPZ 1 zones and higher to prevent overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
Technical data
FLP-12,5 V/3 FLP-12,5 V/3 S
Dimension drawing Basic circuit diagram
connection ofsignalization terminal
14
Lightning Current Arresters
SPD type 1 and type 24-pole arrester for 3-phase TNS networksTotal Iimp= 50kA (10/350)
Varistor lightning and surge current arresters to be installed in low-voltage distributions at the boundary of LPZ 0–LPZ 1 zones and higher to prevent overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
Dimension drawing Basic circuit diagram
Technical data FLP-12,5 V/4
Nominal voltage Un 230 V ACMaximum operating voltage Uc 275 V AC / 350 V DCNominal discharge current (8/20 μs)/pole In 30 kAMaximal discharge current/pole Imax 60 kALightning impulse current (10/350 μs)/pole Iimp 12,5 kAVoltage protection level Up 1,2 kVVoltage protection level @ I = 5 kA (8/20 μs) Up 0,9 kVResponse time ta 25 nsShort-circuit proof at maximum overcurrent protection 50 kArms
Maximum overcurrent protection 160 A gL/gGDegree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication fieldRemote indication – S design potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberFLP-12,5 V/4 8595090534297FLP-12,5 V/4S 8595090534303
Replacement module FLP-12,5 V/0 8595090534310
FLP-12,5 V/4 FLP-12,5 V/4 S
connection ofsignalization terminal
15
L-N N-PE
Nominal voltage Un 230 V AC —Maximum operating voltage Uc 275 V AC 255 V ACNominal discharge current (8/20 μs) In 30 kA 30 kAMaximal discharge current (8/20 μs) Imax 60 kA 60 kALightning impulse current (10/350 μs) Iimp 12,5 kA 25 kAVoltage protection level Up 1,2 kV 1,5 kVVoltage protection level @ I = 5 kA (8/20 μs) Up 0,9 kV —Voltage protection level (L - PE) Up 1,5 kVResponse time ta 25 ns 100 nsAbility independently switch off the following current Ifi no following current 100 AShort-circuit proof at maximum overcurrent protection 50 kArms —Maximum overcurrent protection 160 A gL/gG —Degree of protection IP 20 IP 20Range of operating temperatures – 40 °C … + 80 °C – 40 °C … + 80 °CMounting on DIN rail 35 mm DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4 ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication field noRemote indication – S design potential-free change-over contact —Remote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DC —Cross-section of remote indication conductors max. 1,5 mm2 —
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberFLP-12,5 V/1+1 8595090534235FLP-12,5 V/1S+1 8595090534242
Replacement moduleFLP-12,5 V/0 (for L-N) 8595090534310FLP-NPE 25 V/0 (for N-PE) 8595090534327
Lightning Current Arresters
SPD type 1 and type 22-pole (1+NPE) arrester for single phase TT(TNS) networksTotal Iimp= 25kA (10/350)
Varistor lightning and surge current arrester and heavy duty encapsulated spark gap to be installed in low-voltage distributions at the boundary of LPZ 0–LPZ 1 zones and higher to prevent overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
FLP-12,5 V/1+1FLP-12,5 V/1S+1
Dimension drawing Basic circuit diagram
connection ofsignalization terminal
Technical data
16
L-N N-PE
Nominal voltage Un 230 V AC —Maximum operating voltage Uc 275 V AC 255 V ACNominal discharge current (8/20 μs) In 30 kA 50 kAMaximal discharge current (8/20 μs) Imax 60 kA 100 kALightning impulse current (10/350 μs) Iimp 12,5 kA 50 kAVoltage protection level Up 1,2 kV 1,5 kVVoltage protection level @ I = 5 kA (8/20 μs) Up 0,9 kV —Voltage protection level (L - PE) Up 1,5 kVResponse time ta 25 ns 100 nsAbility independently switch off the following current Ifi no following current 100 AShort-circuit proof at maximum overcurrent protection 50 kArms —Maximum overcurrent protection 160 A gL/gG —Degree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication field noRemote indication – S design potential-free change-over contact —Remote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DC —Cross-section of remote indication conductors max. 1,5 mm2 —
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberFLP-12,5 V/3+1 8595090534273FLP-12,5 V/3S+1 8595090534280
Replacement module FLP-12,5 V/0 8595090534310
Lightning Current Arresters
SPD type 1 and type 24-pole (3+NPE) arrester for 3-phase TT(TNS) networksTotal Iimp= 50kA (10/350)
Varistor lightning and surge current arresters and fixed N-PE modul with heavy duty encapsulated spark gap. To be installed in low-voltage distributions at the boundary of LPZ 0–LPZ 1 zones and higher to prevent overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
FLP-12,5 V/3+1FLP-12,5 V/3S+1
Dimension drawing Basic circuit diagram
connection ofsignalization terminal
Technical data
17
Lightning Current Arresters
SPD type 1 and type 2versatile single-pole arrester
Varistor lightning and surge current arrester to be installed in low-voltage distributions at the boundary of LPZ 0B–LPZ 1 zones and higher to prevent overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
Dimension drawing Basic circuit diagram
FLP-275 VFLP-275 VS
Technical data FLP-275 V
Nominal voltage Un 230 V AC
Maximum operating voltage Uc 275 V AC / 350 V DC
Nominal discharge current (8/20 μs) In 30 kA
Maximum discharge current Imax 60 kA
Lightning impulse current (10/350 μs) Iimp 8 kA
Voltage protection level Up 1,2 kV
Response time ta 25 ns
Short-circuit proof at maximum overcurrent protection 50 kArms
Maximum overcurrent protection 160 A gL/gG
Degree of protection IP 20
Range of operating temperatures – 40 °C … + 80 °C
Mounting on DIN rail 35 mm
Cross-section of connected conductors
Solid min/max ISO: 1/35 mm2 ; AWG: 17/2
Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4
Fault indication red indication field
Remote indication – S design potential-free change-over contact
Remote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DC
Cross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering number FLP-275 V 8595090516200
FLP-275 VS 8595090516217Replacement module FLP-275 V/0 8595090532972
connection ofsignalization terminal
18
Lightning Current Arresters
SPD type 1 and type 23-pole arrester for 3-phase TNC networksTotal Iimp= 24kA (10/350)
Varistor lightning and surge current arresters to be installed in low-voltage distributions at the boundary of LPZ 0B–LPZ 1 zones and higher to prevent overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
Dimension drawing Basic circuit diagram
Technical data FLP-275 V/3
Nominal voltage Un 230 V AC
Maximum operating voltage Uc 275 V AC / 350 V DCNominal discharge current (8/20 μs)/pole In 30 kAMaximum discharge current (8/20 μs)/pole Imax 60 kALightning impulse current (10/350 μs)/pole Iimp 8 kAVoltage protection level Up 1,2 kVResponse time ta 25 nsShort-circuit proof at maximum overcurrent protection 50 kArms
Maximum overcurrent protection 160 A gL/gGDegree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication fieldRemote indication – S design potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberFLP-275 V/3 8595090517757FLP-275 V/3 S 8595090517771
Replacement module FLP-275 V/0 8595090535972
FLP-275 V/3FLP-275 V/3 S
connection of signalization terminal
19
Lightning Current Arresters
SPD type 1 and type 24-pole arrester for 3-phase TNS networksTotal Iimp= 32kA (10/350)
Varistor lightning and surge current arresters to be installed in low-voltage distributions at the boundary of LPZ 0B–LPZ 1 zones and higher to prevent overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
Dimension drawing Basic circuit diagram
Technical data FLP-275 V/4
Nominal voltage Un 230 V AC
Maximum operating voltage Uc 275 V AC / 350 V DCNominal discharge current (8/20 μs)/pole In 30 kAMaximum discharge current (8/20 μs)/pole Imax 60 kALighting impulse current (10/350 μs)/pole Iimp 8 kAVoltage protection level Up 1,2 kVResponse time ta 25 nsShort-circuit proof at maximum overcurrent protection 50 kArms
Maximum overcurrent protection 160 A gL/gGDegree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected condutors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication fieldRemote indication – S design potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberFLP-275 V/4 8595090517788FLP-275 V/4 S 8595090517795
Replacement module FLP-275 V/0 8595090532972
FLP-275 V/4FLP-275 V/4 S
connection of signalization terminal
20
Lightning Current Arresters
SPD type 1 and type 22-pole (1+NPE) arrester for single phase TT(TNS) networks
Varistor lightning and surge current arrester and heavy duty encapsulated spark gap in the mode 1+1. To be installed in low-voltage distributions at the boundary of LPZ 0B and LPZ 1 zones to protect distributions and equipment against the overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
FLP-275 V/1+1FLP-275 V/1S+1
Dimension drawing Basic circuit diagram
connection of signalization terminal
Technical data L-N N-PE
Nominal voltage Un 230 V AC —Maximum operating voltage Uc 275 V AC 255 V ACNominal discharge current (8/20 μs) In 30 kA 20 kAMaximum discharge current (8/20 μs) Imax 60 kA 40 kALighting impulse current (10/350 μs) Iimp 8 kA 25 kAVoltage protection level Up 1,2 kV 1,5 kVVoltage protection level (L - PE) Up 1,5 kVResponse time ta 25 ns 25 nsAbility to independently switch off the following current Ifi no following current 100 AShort-circuit proof at maximum overcurrent protection 50 kArms —Maximum overcurrent protection 160 A gL/gG —Degree of protection IP 20 IP 20Range of operating temperatures – 40 °C … + 80 °C – 40 °C … + 80 °CMounting on DIN rail 35 mm DIN rail 35 mmCross-section of connected condutors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4 ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication field neRemote indication – S design potential-free change-over contact —Remote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DC —Cross-section of remote indication conductors max. 1,5 mm2 —
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberFLP-275 V/1+1 8595090533085FLP-275 V/1S+1 8595090533092
Replacement moduleFLP-275 V/0 (for L-N) 8595090532972FLP-NPE 25 V/0 (for N-PE) 8595090534327
21
Lightning Current Arresters
SPD type 1 and type 24-pole (3+NPE) arrester for 3-phase TT(TNS) networksTotal Iimp= 25kA (10/350)
Varistor lightning and surge current arresters and heavy duty encapsulated spark gap connected in the mode 3+1. To be installed in low-voltage distributions at the boundary of LPZ 0B and LPZ 1 zones to protect distributions and equipment against the overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
FLP-275 V/3+1FLP-275 V/3S+1
Technical data L-N N-PE
Nominal voltage Un 230 V AC —Maximum operating voltage Uc 275 V AC 255 V ACNominal discharge current (8/20 μs)/pole In 30 kA 20 kAMaximum discharge current (8/20 μs)/pole Imax 60 kA 40 kALighting impulse current (10/350 μs)/pole Iimp 8 kA 25 kAVoltage protection level Up 1,2 kV 1,5 kVVoltage protection level (L - PE) Up 1,5 kVResponse time ta 25 ns 100 nsAbility to independently switch off the following current Ifi no following current 100 AShort-circuit proof at maximum overcurrent protection 50 kArms —Maximum overcurrent protection 160 A gL/gG —Degree of protection IP 20 IP 20Range of operating temperatures – 40 °C … + 80 °C – 40 °C … + 80 °CMounting on DIN rail 35 mm DIN rail 35 mmCross-section of connected condutors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4 ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication field noRemote indication – S design potential-free change-over contact —Remote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DC —Cross-section of remote indication conductors max. 1,5 mm2 —
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberFLP-275 V/3+1 8595090531128FLP-275 V/3S+1 8595090531135
Replacement moduleFLP-275 V/0 (for L-N) 8595090532972FLP-NPE 25 V/0 (for N-PE) 8595090534327
Dimension drawing Basic circuit diagram
connection of signalization terminal
22
Surge Arresters
Dimension drawing Basic circuit diagram
Technical data SLP-275 V
Nominal voltage Un 230 V AC
Maximum operating voltage Uc 275 V AC / 350 V DCMaximum operating voltage of varistor —Nominal discharge current (8/20 μs) In 20 kAMaximum discharge current (8/20 μs) Imax 40 kAVoltage protection level @ I = 5 kA (8/20 μs) Up 0,9 kVVoltage protection level Up 1,2 kVResponse time ta 25 nsShort-circuit proof at maximum overcurrent protection 50 kArms
Maximum overcurrent protection 160 A gL/gGDegree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication fieldRemote indication – S version potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberSLP-xxx V 8595090516170
SLP-xxx VS 8595090516187
Replacement module SLP-xxx V/0 8595090523680
SLP-275 VSLP-275 VS
connection ofsignalization terminal
23
SPD type 2versatile single-pole arrester
Varistor surge protection to be installed in low-voltage distributions at the boundary of LPZ 1 and LPZ 2 zones to protect the distributions and equipment against overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Remote status signalling (S).
Surge Arresters
SPD type 2 – surge arrester 3-pole arrester for 3-phase TNC networks
3-pole varistor surge protection to be installed in low-voltage distributions at the boundary of LPZ 1 and LPZ 2 zones to protect the distributions and equipment against overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
SLP-275 V/3SLP-275 V/3S
Dimension drawing Basic circuit diagram
connection of signalization terminal
Technical data SLP-275 V/3
Nominal voltage Un 230 V AC
Maximum operating voltage Uc 275 V AC / 350 V DCNominal discharge current (8/20 μs)/pole In 20 kAMaximum discharge current (8/20 μs)/pole Imax 40 kAVoltage protection level @ I = 5 kA (8/20 μs) Up 0,9 kVVoltage protection level Up 1,2 kVResponse time ta 25 nsShort-circuit proof at maximum overcurrent protection 50 kArms
Maximum overcurrent protection 160 A gL/gGDegree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication fieldRemote indication – S design potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberSLP-275 V/3 8595090517603SLP-275 V/3S 8595090517610
Replacement module SLP-275 V/0 8595090523680
24
Surge Arresters
SPD type 2 – surge arrester 4-pole arrester for 3-phase TNS networks
4-pole varistor surge protection to be installed in low-voltage distributions at the boundary of LPZ 1 and LPZ 2 zones to protect the distributions and equipment against overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
SLP-275 V/4SLP-275 V/4S
Dimension drawing Basic circuit diagram
connection of signalization
terminal
Technical data SLP-275 V/4
Nominal voltage Un 230 V AC
Maximum operating voltage Uc 275 V AC / 350 V DCNominal discharge current (8/20 μs)/pole In 20 kAMaximum discharge current (8/20 μs)/pole Imax 40 kAVoltage protection level @ I = 5 kA (8/20 μs) Up 0,9 kVVoltage protection level Up 1,2 kVResponse time ta 25 nsShort-circuit proof at maximum overcurrent protection 50 kArms
Maximum overcurrent protection 160 A gL/gGDegree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication fieldRemote indication – S design potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberSLP-275 V/4 8595090517221SLP-275 V/4S 8595090517634
Replacement module SLP-275 V/0 8595090523680
25
Surge Arresters
SPD type 2 – surge arrester 2-pole (1+NPE) arrester for single phase TT(TNS) networks
Combination of varistor surge protection and an encapsulated spark gap connected in the mode 1+1. To be installed in low-voltage distributions at the boundary of LPZ 1 and LPZ 2 zones to protect distributions and equipment against the overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
Dimension drawing Basic circuit diagram
Technical data L-N N-PE
Nominal voltage Un 230 V AC —
Maximum operating voltage Uc 275 V AC 255 V AC Nominal discharge current (8/20 μs) In 20 kA 20 kAMaximum discharge current (8/20 μs) Imax 40 kA 40 kALighting impulse current (10/350 μs) Iimp — 15 kAVoltage protection level @ I = 5 kA (8/20 μs) Up 0,9 kV —Voltage protection level Up 1,2 kV 1,5 kVVoltage protection level (L - PE) Up 1,5 kVResponse time ta 25 ns 100 nsAbility to independently switch off the following current Ifi no following current 100 AShort-circuit proof at maximum overcurrent protection 50 kArms —Maximum overcurrent protection 160 A gL/gG —Degree of protection IP 20 IP 20Range of operating temperatures – 40 °C … + 80 °C – 40 °C … + 80 °CMounting on DIN rail 35 mm DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4 ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication field noRemote indication – S design potential-free change-over contact —Remote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DC —Cross-section of remote indication conductors max. 1,5 mm2 —
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberSLP-275 V/1+1 8595090519485SLP-275 V/1S+1 8595090524915
Replacement moduleSLP-275 V/0 (for L-N) 8595090523680SLP-NPE V/0 (for N-PE) 8595090537229
SLP-275 V/1+1SLP-275 V/1S+1
connection of signalization terminal
26
Surge Arresters
SPD type 2 – surge arrester 4-pole (3+NPE) arrester for 3-phase TT(TNS) networks
Combination of 3-pole varistor surge protection and an encapsulated spark gap connected in the mode 3+1. To be installed in low-voltage distributions at the boundary of LPZ 1 and LPZ 2 zones to protect distributions and equipment against the overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
Dimension drawing Basic circuit diagram
Technical data L-N N-PE
Nominal voltage Un 230 V AC —
Maximum operating voltage Uc 275 V AC 255 V AC Nominal discharge current (8/20 μs)/pole In 20 kA 20 kAMaximum discharge current (8/20 μs)/pole Imax 40 kA 40 kALighting impulse current (10/350 μs) Iimp — 15 kAVoltage protection level @ I = 5 kA (8/20 μs) Up 0,9 kV —Voltage protection level Up 1,2 kV 1,5 kVVoltage protection level (L - PE) Up 1,5 kVResponse time ta 25 ns 100 nsAbility to independently switch off the following current Ifi no following current 100 AShort-circuit proof at maximum overcurrent protection 50 kArms —Maximum overcurrent protection 160 A gL/gG —Degree of protection IP 20 IP 20Range of operating temperatures – 40 °C … + 80 °C – 40 °C … + 80 °CMounting on DIN rail 35 mm DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4 ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication field noRemote indication – S design potential-free change-over contact —Remote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DC —Cross-section of remote indication conductors max. 1,5 mm2 —
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberSLP-275 V/3+1 8595090519461SLP-275 V/3S+1 8595090520023
Replacement moduleSLP-275 V/0 (for L-N) 8595090523680SLP-NPE V/0 (for N-PE) 8595090537229
SLP-275 V/3+1SLP-275 V/3S+1
connection of signalization
terminal
27
Surge Arresters
Dimension drawing Basic circuit diagram
Technical data SLP-075 V SLP-150 V SLP-385 V SLP-440 V SLP-600 V
Nominal voltage Un — 120 V AC — 400 V AC —
Maximum operating voltage Uc 75 V AC / 100 V DC 150 V AC / 200 V DC 385 V AC / 500 V DC 440 V AC / 585 V DC 600 V ACMaximum operating voltage of varistor — — — — 880 V ACNominal discharge current (8/20 μs) In 15 kA 15 kA 20 kA 20 kA 15 kAMaximum discharge current (8/20 μs) Imax 40 kA 40 kA 40 kA 40 kA 40 kAVoltage protection level @ I = 5 kA (8/20 μs) Up 0,3 kV 0,45 kV 1,3 kV 1,5 kV 2,7 kVVoltage protection level Up 0,4 kV 0,6 kV 1,8 kV 1,9 kV 3,2 kVResponse time ta 25 ns 25 ns 25 ns 25 ns 25 nsShort-circuit proof at maximum overcurrent protection 50 kArms 50 kArms 50 kArms 50 kArms 50 kArms
Maximum overcurrent protection 160 A gL/gG 160 A gL/gG 160 A gL/gG 160 A gL/gG 160 A gL/gGDegree of protection IP 20Range of operating temperatures – 40 °C … + 80 °CMounting on DIN rail 35 mmCross-section of connected conductors Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4Fault indication red indication fieldRemote indication – S version potential-free change-over contactRemote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DCCross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering numberSLP-xxx V 8595090518150 8595090551850 8595090519553 8595090518174 8595090533016
SLP-xxx VS 8595090518235 8595090551867 8595090527718 8595090518259 8595090533023
Replacement module SLP-xxx V/0 8595090518112 8595090551935 8595090519508 8595090518136 8595090533030
SLP-075 V(S)SLP-150 V(S)SLP-385 V(S)SLP-440 V(S)SLP-600 V(S)
SPD type 2versatile single-pole arrester
Varistor surge protection to be installed in low-voltage distributions at the boundary of LPZ 1 and LPZ 2 zones to protect the distributions and equipment against overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Remote status signalling (S). Multi-pole versions and other (special) voltages on request.
connection ofsignalization terminal
28
Surge Arresters
Dimension drawing Basic circuit diagram
Technical data SLP-075 VB SLP-130 VB SLP-275 VB
Nominal voltage Un — 120 V AC 230 V AC
Maximum operating voltage Uc 75 V AC / 100 V DC 135 V AC / 175 V DC 275 V AC / 350 V DC
Nominal discharge current (8/20 μs) In 15 kA 20 kA 20 kA
Maximum discharge current (8/20 μs) Imax 25 kA 25 kA 25 kA
Voltage protection level @ I = 5 kA (8/20 μs) Up 0,3 kV 0,5 kV 0,9 kV
Voltage protection level Up 0,6 kV 0,7 kV 1,2 kV
Response time ta 100 ns 100 ns 100 ns
Short-circuit proof at maximum overcurrent protection 35 kArms 35 kArms 35 kArms
Maximum overcurrent protection 125 A gL/gG 125 A gL/gG 125 A gL/gG
Degree of protection IP 20 IP 20 IP 20
Range of operating temperatures – 40 °C … + 80 °C – 40 °C … + 80 °C – 40 °C … + 80 °C
Mounting on DIN rail 35 mm DIN rail 35 mm DIN rail 35 mm
Cross-section of connected conductors
Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 ISO: 1/35 mm2 ; AWG: 17/2 ISO: 1/35 mm2 ; AWG: 17/2
Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4 ISO: 1/25 mm2 ; AWG: 17/4 ISO: 1/25 mm2 ; AWG: 17/4
Fault indication red indication field red indication field red indication field
Remote indication – S design potential-free change-over contact
Remote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DC
Cross-section of remote indication conductors max. 1,5 mm2
Meets the requirements of standard IEC 61643-11 ed. 1.0 EN 61643-11:2012
IEC 61643-11 ed. 1.0 EN 61643-11:2012
IEC 61643-11 ed. 1.0 EN 61643-11:2012
Ordering number SLP-xxx VB 8595090521556 8595090552147 8595090519447
SLP-xxx VBS 8595090521563 8595090552154 8595090519454
Replacement module SLP-xxx VB/0 8595090521549 8595090552161 8595090519430
SLP-075 VB(S)SLP-130 VB(S)SLP-275 VB(S)SPD type 2 – surge arrester Replaceable module, visual fault signalling
Efficient varistor connected in series with an encapsulated spark gap. To be installed in low-voltage distributions at the boundary of LPZ 1 and LPZ 2 zones. Designed to protect distributions and equipment against the overvoltage effects induced during a lightning strike and to prevent switching overvoltage in areas with higher storm activity or to protect measuring circuits as a 1st protection level. In idle state it has very little leakage current, which remains stable for the duration of the service life; protective elements are not subject to ageing.Optional remote status signalling (S).
connection of signalization
terminal
29
Surge Arresters
SPD type 3 – surge arresterReplaceable module, visual fault signalling
Combination of varistor surge protection and an encapsulated spark gap connected in the mode 1+1. To be installed in low-voltage distributions at the boundary of LPZ 2 and LPZ 3 zones to protect distributions and equipment against overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
Dimension drawing Basic circuit diagram
Technical data L-N N-PE
Nominal voltage Un 230 V AC —
Maximum operating voltage Uc 275 V AC 255 V AC
Nominal discharge current (8/20 μs) In 5 kA 10 kA
Test voltage Uoc 10 kV 20 kV
Voltage protection level Up 1 kV 1,5 kV
Voltage protection level (L - PE) Up 1,5 kV
Response time ta 25 ns 100 ns
Maximum overcurrent protection 63 A gL/gG —
Degree of protection IP 20 IP 20
Range of operating temperatures – 40 °C … + 80 °C – 40 °C … + 80 °C
Mounting on DIN rail 35 mm DIN rail 35 mm
Cross-section of connected conductors
Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 ISO: 1/35 mm2 ; AWG: 17/2
Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4 ISO: 1/25 mm2 ; AWG: 17/4
Fault indication red indication field no
Remote indication – S design potential-free change-over contact —
Remote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DC —
Cross-section of remote indication conductors max. 1,5 mm2 —
Meets the requirements of standard EN 61643-11 + A11 EN 61643-11 + A11
Ordering numberDA-275 V/1+1 8595090518723
DA-275 V/1S+1 8595090519751
Replacement moduleDA-275 V/0 (for L-N) 8595090518518
DA-NPE V/0 (for N-PE) 8595090530046
DA-275 V/1+1DA-275 V/1S+1
connection of signalization terminal
30
Surge Arresters
SPD type 3 – surge arresterReplaceable module, visual fault signalling
Combination of 3-pole varistor surge protection and an encapsulated spark gap connected in the mode 3+1. To be installed in low-voltage distributions at the boundary of LPZ 2 and LPZ 3 zones to protect distributions and equipment against overvoltage effects induced during a lightning strike and to prevent switching overvoltage. Optional remote status signalling (S).
Dimension drawing Basic circuit diagram
Technické parametry L-N N-PE
Nominal voltage Un 230 V AC —
Maximum operating voltage Uc 275 V AC 255 V AC
Nominal discharge current (8/20 μs)/pole In 5 kA 10 kA
Test voltage Uoc 10 kV 20 kV
Voltage protection level Up 1 kV 1,5 kV
Voltage protection level (L - PE) Up 1,5 kV
Response time ta 25 ns 100 ns
Maximum overcurrent protection 63 A gL/gG —
Degree of protection IP 20 IP 20
Range of operating temperatures – 40 °C … + 80 °C – 40 °C … + 80 °C
Mounting on DIN rail 35 mm DIN rail 35 mm
Cross-section of connected conductors
Solid min/max ISO: 1/35 mm2 ; AWG: 17/2 ISO: 1/35 mm2 ; AWG: 17/2
Stranded min/max ISO: 1/25 mm2 ; AWG: 17/4 ISO: 1/25 mm2 ; AWG: 17/4
Fault indication red indication field no
Remote indication – S design potential-free change-over contact —
Remote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DC —
Cross-section of remote indication conductors max. 1,5 mm2 —
Meets the requirements of standard EN 61643-11 + A11 EN 61643-11 + A11
Ordering numberDA-275 V/3+1 8595090518488
DA-275 V/3S+1 8595090518495
Replacement moduleDA-275 V/0 (for L-N) 8595090518518
DA-NPE V/0 (for N-PE) 8595090530046
DA-275 V/3+1DA-275 V/3S+1
connection of signalization
terminal
31
Surge Arresters
AccessoriesSALTEK SPD type 1–3 with a “V“ in the part number are made with replaceable modules. This enables simple withdrawal of the module from its base to test the systems insulation, without the need to disconnect the device from the circuit. Furthermore the new modules enable simple up-down orientation of the SPD, according to the incoming cables and also it serve for fast and easy replacement in case of failure.The replacement modules (marked “xxx V/0”) are identical to the ones used in original product.The voltages used cannot be mixed because of the identical voltage key on the module and the corresponding base part.
Dimension drawing
Replaceable modules
type ordering number
FLP-12,5 V/0 8595090534310
FLP-NPE 25 V/0 8595090534327
SLP-075 V/0 8595090518112
FLP-275 V/0 8595090532972
SLP-150 V/0 8595090551935
SLP-275 V/0 8595090523680
SLP-385 V/0 8595090519508
SLP-440 V/0 8595090518136
SLP-600 V/0 8595090533030
SLP-075 VB/0 8595090521549
SLP-150 VB/0 8595090552161
SLP-275 VB/0 8595090519430
SLP-NPE V/0 8595090537229
DA-275 V/0 8595090518518
DA-NPE V/0 8595090530046
type ordering code
FLP-B+C MAXI V/0 8595090535355
FLP-A50N V/0 8595090535379
FLP-A100N V/0 8595090535362
36 mm (2TE) 18 mm (1TE)
Illustration photo Illustration photo
32
3652,5
Surge Arresters
SPD type 3 – surge arresterVisual fault signalling
Surge protection designed to protect all types of electric and electronic equipment connected to a low-voltage distribution against pulse overvoltage.
Dimension drawing Basic circuit diagram
Technical data DA-075 DJ DA-130 DJ DA-275 DJ
Nominal voltage Un — 110 V AC 230 V AC
Maximum operating voltage Uc 75 V AC 130 V AC 275 V AC
Nominal discharge current (8/20 μs) L-N, L(N)-PE, L+N-PE In 2 kA, 2 kA, 4 kA 2,5 kA, 2,5 kA, 5 kA 3 kA, 3 kA, 5 kA
Test voltage L-N, L(N)-PE, L+N-PE Uoc 4 kV, 4 kV, 8 kV 5 kV, 5 kV, 10 kV 6 kV, 6 kV, 10 kV
Voltage protection level L-N, L(N)-PE Up 0,4 kV, 1,2 kV 0,6 kV, 1,5 kV 1,2 kV, 1,6 kV
Response time L-N, L(N)-PE ta 25 ns, 100 ns 25 ns, 100 ns 25 ns, 100 ns
Short-circuit proof at maximum overcurrent protection 6 kA rms 6 kA rms 6 kA rms
Maximum overcurrent protection 16 A gL/gG; C 16 A 16 A gL/gG; C 16 A 16 A gL/gG; C 16 A
Degree of protection IP 20 IP 20 IP 20
Range of operating temperatures – 40 °C … + 80 °C – 40 °C … + 80 °C – 40 °C … + 80 °C
Mounting on DIN rail 35 mm DIN rail 35 mm DIN rail 35 mm
Cross-section of connected conductors
Solid max ISO: 6 mm2 ; AWG: 10 ISO: 6 mm2 ; AWG: 10 ISO: 6 mm2 ; AWG: 10
Stranded max ISO: 4 mm2 ; AWG: 11 ISO: 4 mm2 ; AWG: 11 ISO: 4 mm2 ; AWG: 11
Fault indication red indicator red indicator red indicator
Meets the requirements of standard EN 61643-11 + A11 EN 61643-11 + A11 EN 61643-11 + A11
Ordering number 8595090533191 8595090521891 8595090506362
DA-075 DJDA-130 DJDA-275 DJ
33
Surge Arresters
SPD type 3 – surge arrester
Surge protection designed to protect all types of electric and electronic equipment connected to a low-voltage distribution against pulse overvoltage.
Dimension drawing Basic circuit diagram
Technical data DA-275 A
Nominal voltage Un 230 V AC
Maximum operating voltage Uc 275 V AC
Nominal discharge current (8/20 μs) L-N, L(N)-PE In 2,0 kA, 2,0 kA
Test voltage L-N, L(N)-PE Uoc 4,0 kV, 4,0 kV
Voltage protection level L-N, L(N)-PE Up 1,5 kV, 1,5 kV
Response time L-N, L(N)-PE ta 25 ns, 100 ns
Maximum overcurrent protection 16 A gL/gG or B16 A
TOV 5 s L-N 335 V
Degree of protection IP 20
Range of operating temperatures – 25 °C … + 40 °C
Mounting on in wiring boxes
Fault indication acoustic signalling
Remote indication no
Meets the requirements of standard EN 61643-11:2012
Ordering number 8595090540472
DA-275 A
L/N
PE
N/L
TEST
34
Surge Arresters
SPD type 3 – surge arresterRemote fault signalling
Surge protection for additional installation in devices, equipment, etc. designed to protect all types of low-voltage electric and electronic equipment against pulse overvoltage.
Dimension drawing Basic circuit diagram
DA-275 CZS
C 16 A
remoteindication contact
group of protectedoutlets
Technical data DA-275 CZS
Nominal voltage Un 230 V AC
Maximum operating voltage Uc 275 V AC
Nominal discharge current (8/20 μs) L-N, L(N)-PE In 3,0 kA, 3,0 kA
Test voltage L-N, L(N)-PE Uoc 6 kV, 6 kV
Voltage protection level L-N, L(N)-PE Up 1,0 kV, 1,5 kV
Response time L-N, L(N)-PE ta 25 ns, 100 ns
Maximum overcurrent protection 16 A gL/gG or C16 A
TOV 5 s L-N 335 V
TOV 5 s L-PE 400 V
TOV 200 ms L-PE 1 430 V
Degree of protection IP 20
Range of operating temperatures –25 °C … + 40 °C
Mounting in wiring boxes
Fault indication open contact
Remote indication potential-free open contact
Remote indication contacts 230 V AC/0,5 A, 24 V DC/0,5 A
Meets the requirements of standard EN 61643-11 + A11
Ordering number 8595090519164
35
25
10 20 300
15,8
PRODUCT RANGE
For more details please contact us or visit www.saltek.eu
Low voltageSPD type 1, type 2 and type 3 for lightning and surge protectionof LV distribution systems
Renewable energySPD for photovoltaic applications (AC side, DC side, communication lines),electric vehicle charging stations, wind turbines and biogas plants
Surger protection with RFI filterSPD type 3 to protect against surges and high frequency interferencevoltages caused by inverters
Control linesSurge protection devices for AI, AO, DI, DO and bus forcontrol, security or fire protection systems
Telecom linesSurge protection devices for analog, ISDN and ADSL lines and other DSLlines for installation on DIN rail or LSA-PLUS
Video/securitySurge protection devices for coaxial lines for N/F/BNC connectors for useon frequencies 0-5,8 GHz.
EthernetSurge protection devices for Ethernet category 5 and 6 and for Power overEthernet (POE, POE PLUS)
Manufactureand headquarter
SALTEK s.r.o.Drážďanská 85400 07 Ústí nad LabemCzech Republic
tel.: +420 475 655 511fax: +420 475 622 213GSM: +420 602 413 437e-mail: [email protected]
Sales officeand technical support
SALTEK TRADE, s.r.o.Vodňanská 1419/229198 00 Praha 9Czech Republic
tel.: +420 272 942 470fax: +420 267 913 411GSM: +420 602 472 633 e-mail: [email protected]
www.saltek.eu EN 2014/04