catalog - grand voltagegrandvoltage.ro/.../catalogs/grand_voltage_generators_catalog.pdf · catalog...

181
CATALOG generators 2016 beyond energy, it's power

Upload: trinhhanh

Post on 18-Aug-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

CATALOGgenerators 2016

beyond energy, it's power

1

Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code

OpenOrder Code

CanopiedSTAND-BY POWER

PRIME POWER

OPEN CANOPIED OPEN CANOPIED

GVP-G10 10 kVA 9 kVA 800x2000x1200 930x2100x1000 650 850 GV31464777 GV31464806

GVP-G15 15 kVA 13 kVA 800x2000x1200 930x2100x1000 650 850 GV31464778 GV31464807

GVP-G22 22 kVA 20 kVA 800x2000x1200 930x2100x1000 650 850 GV31464779 GV31464808

GVP-G33 33 kVA 30 kVA 900x1800x1420 950x2300x1720 792 1120 GV31464780 GV31464809

GVP-G50 50 kVA 42,5 kVA 900x1800x1420 900x2300x1720 859 1187 GV31464781 GV31464810

GVP-G66 66 kVA 60 kVA 900x1800x1420 900x2300x1720 890 1250 GV31464782 GV31464811

GVP-G72 72 kVA 65 kVA 900x1800x1420 900x2300x1720 945 1280 GV31464783 GV31464812

GVP-G88 88 kVA 80 kVA 1100x2100x1650 1100x2800x1830 955 1460 GV31464784 GV31464813

GVP-G110 110 kVA 100 kVA 1100x2100x1650 1100x2800x1830 1550 2235 GV31464785 GV31464814

GVP-G150 150 kVA 136 kVA 1100x2100x1650 1100x2800x1830 1600 2300 GV31464786 GV31464815

GVP-G165 165 kVA 150 kVA 1200x2800x1720 1200x2800x2220 2100 2750 GV31464787 GV31464816

GVP-G200 200 kVA 180 kVA 1200x2800x1720 1200x2800x2220 2115 2780 GV31464788 GV31464817

GVP-G220 220 kVA 200 kVA 1200x2800x1720 1200x2800x2220 2115 2780 GV31464789 GV31464818

GVP-G275 275 kVA 250 kVA 1500x2800x1720 1500x2800x2580 2021 3006 GV31464790 GV31464819

GVP-G300 300 kVA 275 kVA 1500x3100x1960 1500x4200x2580 2900 4000 GV314617400 GV314617402

GVP-G330 330 kVA 300 kVA 1500x2800x1720 1500x2800x2580 3004 4404 GV314617401 GV314617403

GVP-G400 400 kVA 350 kVA 1500x3100x1900 1500x4200x2580 3440 4400 GV31464791 GV31464820

GVP-G450 450 kVA 400 kVA 1500x3100x1900 1500x4200x2580 3520 4420 GV31464792 GV31464821

GVP-G500 500 kVA 455 kVA 1500x3500x2170 1500x4600x2810 3880 4780 GV31464793 GV31464822

GVP-G550 550 kVA 65 kVA 1500x3500x2170 1500x4600x2810 4070 5090 GV31464794 GV31464823

GVP-G660 660 kVA 600 kVA 1500x3500x2200 1500x4600x2810 4180 5090 GV31464795 GV31464824

GVP-G700 700 kVA 650 kVA 2100x3350x2200 2440x6060x2590 5070 7450 GV31464796 GV31464825

GVP-G825 825 kVA 750 kVA 2100x3350x2200 2440x6060x2590 6604 8414 GV31464797 GV31464826

GVP-G900 900 kVA 800 kVA 2100x3900x2220 2430x6050x2590 7264 9014 GV31464798 GV31464827

GVP-1000 1000 kVA 900 kVA 2100x4650x2550 2430x6050x2590 9300 11050 GV314622839 GV314622840

GVP-G1100 1100 kVA 1000 kVA 2100x4650x2550 2430x6050x2590 9610 11350 GV31464799 GV31464828

GVP-G1385 1385 kVA 1250 kVA 2100x4650x2550 2430x6050x2890 9720 15220 GV31464800 GV31464829

GVP-G1650 1650 kVA 1500 kVA 2400x5500x2690 2430x9080x3150 9920 16120 GV31464801 GV31464830

GVP-G1880 1880 kVA 1710 kVA 2400x5500x2690 2430x12190x3220 10700 19280 GV31464802 GV31464831

GVP-G2000 2000 kVA 1850 kVA 2430x6500x2690 3000x12190x3220 12145 20400 GV31464803 GV31464832

GVP-G2250 2250 kVA 2025 kVA 2430x6500x2690 3000x12190x3220 12350 20600 GV31464804 GV31464833

GVP-G2500 2500 kVA 2250 kVA 2430x6500x2690 3000x12190x3220 16300 20900 GV31464805 GV31464834

2

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power10 kVA

8 KW

Prime Power9 kVA

7,2 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 403A-11G1

No of Cylinder / Configuration 3 / IN LINE

Displacement (lt) 1,1

Bore / Stroke (mm) 77 / 81

Cycle 4

Compression Ratio 23 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 5,2

Lubrication Oil Capacity (lt) 4,9

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 8,5

Fuel Consumption (lt/h)100% 2,6

50% 2

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-12

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %82

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 930x2100x1000 850 100

OPEN SET 800x2000x1200 650 100

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G10 DIESEL GENERATOR SET / 50Hz

3

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power15 kVA

12 KW

Prime Power13 kVA

10,4 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 403A-15G1

No of Cylinder / Configuration 3 / IN LINE

Displacement (lt) 1,5

Bore / Stroke (mm) 84 / 90

Cycle 4

Compression Ratio 22.5 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 6

Lubrication Oil Capacity (lt) 6

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 12

Fuel Consumption (lt/h)100% 3,6

50% 2

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-15

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %83

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 930x2100x1000 850 100

OPEN SET 800x2000x1200 650 100

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G15 DIESEL GENERATOR SET / 50Hz

4

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power22 kVA

17,6 KW

Prime Power20 kVA

16 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 404A-22G1

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 2,2

Bore / Stroke (mm) 84 / 100

Cycle 4

Compression Ratio 23.3 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 7

Lubrication Oil Capacity (lt) 10,6

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 18,5

Fuel Consumption (lt/h)100% 5,3

50% 2.9

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-25

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %8

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 930x2100x1000 850 100

OPEN SET 800x2000x1200 650 100

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G22 DIESEL GENERATOR SET / 50Hz

5

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power33 kVA

26,4 KW

Prime Power30 kVA

24 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1103A-33G

No of Cylinder / Configuration 3 / IN LINE

Displacement (lt) 3,3

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 19.25 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 10,2

Lubrication Oil Capacity (lt) 8,3

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 27,7

Fuel Consumption (lt/h)100% 7,2

50% 4,06

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-33

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %88

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 950x2300x1720 1120 100

OPEN SET 900x1800x1420 792 100

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G33 DIESEL GENERATOR SET / 50Hz

6

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power50 kVA

40 KW

Prime Power45 kVA

36 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1103A-33TG1

No of Cylinder / Configuration 3 / IN LINE

Displacement (lt) 3,3

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 17.25 :1

Aspiration Turbo

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 10,2

Lubrication Oil Capacity (lt) 8,3

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 41,3

Fuel Consumption (lt/h)100% 10,8

50% 5,83

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-50

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %89

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 900x2300x1720 1185 200

OPEN SET 900x1800x1420 860 200

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G50 DIESEL GENERATOR SET / 50Hz

7

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power66 kVA

52,8 KW

Prime Power60 kVA

48 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1103A33TG2

No of Cylinder / Configuration 3 / IN LINE

Displacement (lt) 3,3

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 17.25 :1

Aspiration Turbo

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 10,2

Lubrication Oil Capacity (lt) 7,9

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 53,8

Fuel Consumption (lt/h)100% 14,6

50% 7,56

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-75

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %90

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 900x2300x1720 1250 200

OPEN SET 900x1800x1420 890 200

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G66 DIESEL GENERATOR SET / 50Hz

8

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power72 kVA

57,6 KW

Prime Power65 kVA

52 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1104A-44TG1

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,4

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 17.25 :1

Aspiration Turbo

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 13

Lubrication Oil Capacity (lt) 8

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 58,4

Fuel Consumption (lt/h)100% 14,8

50% 8

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-75

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %91

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 900x2300x1720 1280 200

OPEN SET 900x1800x1420 945 200

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G72 DIESEL GENERATOR SET / 50Hz

9

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power88 kVA

70,4 KW

Prime Power80 kVA

64 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1104A-44TG2

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,4

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 17.25: 1

Aspiration Turbo

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 13

Lubrication Oil Capacity (lt) 8

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 71,9

Fuel Consumption (lt/h)100% 18,7

50% 9,7

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-88

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %91

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1100x2800x1830 1460 200

OPEN SET 1100x2100x1650 955 200

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G88 DIESEL GENERATOR SET / 50Hz

10

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power110 kVA

88 KW

Prime Power100 kVA

80 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1104C-44TAG2

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,4

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 18.2 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 12,6

Lubrication Oil Capacity (lt) 8

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 89

Fuel Consumption (lt/h)100% 22,6

50%11,2

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-110

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %92

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1100x2800x1830 2235 240

OPEN SET 1100x2100x1650 1550 240

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G110 DIESEL GENERATOR SET / 50Hz

11

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power150 kVA

120 KW

Prime Power136 kVA

108,8 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1106A-70TG1

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6

Bore / Stroke (mm) 100 / 127

Cycle 4

Compression Ratio 17.0 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 37,2

Lubrication Oil Capacity (lt) 19

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 121

Fuel Consumption (lt/h)100% 31,5

50% 16,5

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-150

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %92,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1100x2800x1830 2300 240

OPEN SET 1100x2100x1650 1600 240

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G150 DIESEL GENERATOR SET / 50Hz

12

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power165 kVA

132 KW

Prime Power150 kVA

120 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1106A-70TAG2

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6

Bore / Stroke (mm) 100 / 127

Cycle 4

Compression Ratio 17.0 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 37,2

Lubrication Oil Capacity (lt) 19

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 133,2

Fuel Consumption (lt/h)100% 41

50% 20

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-165

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1200x2800x2220 2750 340

OPEN SET 1200x2800x1720 2100 340

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G165 DIESEL GENERATOR SET / 50Hz

13

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power200 kVA

160 KW

Prime Power180 kVA

144 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1106A-70TAG3

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,6

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 16.2 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 21

Lubrication Oil Capacity (lt) 16,5

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 158,4

Fuel Consumption (lt/h)100% 40,2

50% 20,5

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-200

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1200x2800x2220 2780 340

OPEN SET 1200x2800x1720 2115 340

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G200 DIESEL GENERATOR SET / 50Hz

14

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power220 kVA

176 KW

Prime Power200 kVA

160 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1106A-70TAG4

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 8,7

Bore / Stroke (mm) 116,6 / 135,9

Cycle 4

Compression Ratio 16.9 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 37,2

Lubrication Oil Capacity (lt) 28,3

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 174

Fuel Consumption (lt/h)100% 43,8

50% 26,4

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT 220

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1200x2800x2220 2780 400

OPEN SET 1200x2800x1720 2115 400

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G220 DIESEL GENERATOR SET / 50Hz

15

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power275 kVA

220 KW

Prime Power250 kVA

200 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1506A-E87TAG3

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 8,7

Bore / Stroke (mm) 116,6 / 135,9

Cycle 4

Compression Ratio 16.9 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 37,2

Lubrication Oil Capacity (lt) 28,3

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 217

Fuel Consumption (lt/h)100% 54

50% 31

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-275

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x2800x2580 3006 400

OPEN SET 1500x2800x1720 2021 400

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G275 DIESEL GENERATOR SET / 50Hz

16

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power300 kVA

240 KW

Prime Power275 kVA

220 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1506A-E87TAG4

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 9,3

Bore / Stroke (mm) 117 / 146

Cycle 4

Compression Ratio 16.9 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 33

Lubrication Oil Capacity (lt) 31

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 269

Fuel Consumption (lt/h)100% 71

50% 39

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-330

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4200x2580 4000 500

OPEN SET 1500x3100x1960 2900 500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G300 DIESEL GENERATOR SET / 50Hz

17

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power330 kVA

264 KW

Prime Power297 kVA

237 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1506A-E88TAG5

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 8,8

Bore / Stroke (mm) 112 / 149

Cycle 4

Compression Ratio 16.1 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 29,6

Lubrication Oil Capacity (lt) 41

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 293

Fuel Consumption (lt/h)100% 65

50% 33

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-330

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x2800x2580 4404 500

OPEN SET 1500x2800x1720 3004 500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G330 DIESEL GENERATOR SET / 50Hz

18

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power400 kVA

320 KW

Prime Power350 kVA

280 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 2206C-E13TAG2

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 13

Bore / Stroke (mm) 137 / 157

Cycle 4

Compression Ratio 16.3 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 51,4

Lubrication Oil Capacity (lt) 40

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 305

Fuel Consumption (lt/h)100% 71

50% 37

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-400

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4200x2580 4400 800

OPEN SET 1500x3100x1900 3440 800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G400 DIESEL GENERATOR SET / 50Hz

19

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power450 kVA

360 KW

Prime Power400 kVA

320 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 2206A-E13TAG3

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 13

Bore / Stroke (mm) 137 / 157

Cycle 4

Compression Ratio 16.3 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 51,4

Lubrication Oil Capacity (lt) 40

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 350

Fuel Consumption (lt/h)100% 81

50% 42

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-450

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4200x2580 4420 800

OPEN SET 1500x3100x1900 3520 800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G450 DIESEL GENERATOR SET / 50Hz

20

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power500 kVA

400 KW

Prime Power455 kVA

364 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 2506A-E15TAG1

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 15

Bore / Stroke (mm) 137 / 171

Cycle 4

Compression Ratio 16.0 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 58

Lubrication Oil Capacity (lt) 62

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 396

Fuel Consumption (lt/h)100% 95

50% 50

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-500

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %95

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4600x2810 4780 800

OPEN SET 1500x3500x2170 3880 800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G500 DIESEL GENERATOR SET / 50Hz

21

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power550 kVA

450 KW

Prime Power500 kVA

400 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 2506A-E15TAG2

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 15

Bore / Stroke (mm) 137 / 171

Cycle 4

Compression Ratio 16.0 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 58

Lubrication Oil Capacity (lt) 62

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 435

Fuel Consumption (lt/h)100% 106

50% 55

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-550

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %95

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4600x2810 5090 800

OPEN SET 1500x3500x2170 4070 800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G550 DIESEL GENERATOR SET / 50Hz

22

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power660 kVA

528 KW

Prime Power600 kVA

480 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 2806A-E18TAG1A

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 18

Bore / Stroke (mm) 145 / 183

Cycle 4

Compression Ratio 14.5 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 61

Lubrication Oil Capacity (lt) 62

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 522

Fuel Consumption (lt/h)100% 122

50% 61

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-660

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %95

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4600x2810 5090 1500

OPEN SET 1500x3500x2200 4180 1500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G660 DIESEL GENERATOR SET / 50Hz

23

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power700 kVA

560 KW

Prime Power650 kVA

520 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 2806A-E18TAG2

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 18

Bore / Stroke (mm) 145 / 183

Cycle 4

Compression Ratio 14.5 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 61

Lubrication Oil Capacity (lt) 62

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 565

Fuel Consumption (lt/h)100% 125

50% 63

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-700

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %95

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2440x6060x2590 7450 1500

OPEN SET 2100x3350x2200 5070 1500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G700 DIESEL GENERATOR SET / 50Hz

24

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power825 kVA

660 KW

Prime Power750 kVA

600 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4006-23TAG2A

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 23

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 105

Lubrication Oil Capacity (lt) 113,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 632

Fuel Consumption (lt/h)100% 155

50% 80

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-850

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %95

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2440x6060x2590 8414 1500

OPEN SET 2100x3350x2200 6604 1500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G825 DIESEL GENERATOR SET / 50Hz

25

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power900 kVA

720 KW

Prime Power800 kVA

640 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4006-23TAG3A

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 23

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 105

Lubrication Oil Capacity (lt) 113,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 679

Fuel Consumption (lt/h)100% 172

50% 90

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-950

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2590 9010 1500

OPEN SET 2100x3900x2220 7260 1500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G900 DIESEL GENERATOR SET / 50Hz

26

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1000 kVA

800 KW

Prime Power900 kVA

720 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4008-TAG1A

No of Cylinder / Configuration 8 / IN LINE

Displacement (lt) 30

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 143

Lubrication Oil Capacity (lt) 153

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 882

Fuel Consumption (lt/h)100% 195

50% 98

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-1000

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %95

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2590 11050 2000

OPEN SET 2100x4650x2550 9300 2000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G1000 DIESEL GENERATOR SET / 50Hz

27

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1100 kVA

880 KW

Prime Power990 kVA

792 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4008-TAG2A

No of Cylinder / Configuration 8 / IN LINE

Displacement (lt) 30

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.60 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 149

Lubrication Oil Capacity (lt) 153

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 861

Fuel Consumption (lt/h)100% 226

50% 130

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-1100

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %95,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2590 11350 2400

OPEN SET 2100x4650x2550 9600 2400

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G1100 DIESEL GENERATOR SET / 50Hz

28

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1385 kVA

1108 KW

Prime Power1250 kVA

1000 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4012-46TWG2A

No of Cylinder / Configuration 12 / V

Displacement (lt) 45

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 159

Lubrication Oil Capacity (lt) 201

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1055

Fuel Consumption (lt/h)100% 259

50% 143

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-1500

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %95,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2890 15220 2800

OPEN SET 2100x4650x2550 9720 2800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G1385 DIESEL GENERATOR SET / 50Hz

29

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1650 kVA

1320 KW

Prime Power1500 kVA

1204 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4012-46TAG2A

No of Cylinder / Configuration 12 / V

Displacement (lt) 46

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.00 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 177

Lubrication Oil Capacity (lt) 240

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1267

Fuel Consumption (lt/h)100% 301

50% 165

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-1670

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %96

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x9080x3150 16120 3000

OPEN SET 2400x5500x2690 9920 3000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G1650 DIESEL GENERATOR SET / 50Hz

30

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1880 kVA

1504 KW

Prime Power1710 kVA

1368 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 401246TAG3A

No of Cylinder / Configuration 12 / V

Displacement (lt) 46

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 177

Lubrication Oil Capacity (lt) 210

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1440

Fuel Consumption (lt/h)100% 370

50% 187

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-2000

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x12190x3220 19280 3000

OPEN SET 2400x5500x2690 10700 3000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G1880 DIESEL GENERATOR SET / 50Hz

31

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power2000 kVA

1622 KW

Prime Power1850 kVA

1476 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4016TAG1A

No of Cylinder / Configuration 16 / V

Displacement (lt) 46

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 237,2

Lubrication Oil Capacity (lt) 316

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1537

Fuel Consumption (lt/h)100% 370

50% 191

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-2000

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %97

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 3000x12190x3220 20400 3400

OPEN SET 2430x6500x2690 12145 3400

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G2000 DIESEL GENERATOR SET / 50Hz

32

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power2250 kVA

1800 KW

Prime Power2025 kVA

1620 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4016-TAG2A

No of Cylinder / Configuration 16 / V

Displacement (lt) 46

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 237,2

Lubrication Oil Capacity (lt) 316

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1715

Fuel Consumption (lt/h)100% 421

50% 217

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-2250

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %97

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 3000x12190x3220 20600 3500

OPEN SET 2430x6500x2690 12350 3500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G2250 DIESEL GENERATOR SET / 50Hz

33

www.grandvoltage.roPERKINS – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power2500 kVA

2000 KW

Prime Power2250 kVA

1800 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4016-61TRG3

No of Cylinder / Configuration 16 / V

Displacement (lt) 61.123

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 270

Lubrication Oil Capacity (lt) 237

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1975

Fuel Consumption (lt/h)100% 470

50% 234

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-2500

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %97

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 3000x12190x3220 20900 3500

OPEN SET 2430x6500x2690 16300 3500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-G2500 DIESEL GENERATOR SET / 50Hz

34

Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code

OpenOrder Code

CanopiedSTAND-BY POWER

PRIME POWER

OPEN CANOPIED OPEN CANOPIED

GVP-S10 10 kVA 9 kVA 800x2000x1200 930x2100x1000 650 850 GV31464835 GV31464864

GVP-S15 15 kVA 13 kVA 800x2000x1200 930x2100x1000 650 850 GV31464836 GV31464865

GVP-S22 22 kVA 20 kVA 800x2000x1200 745x2000x1400 650 850 GV31464837 GV31464866

GVP-S33 33 kVA 30 kVA 900x1800x1420 950x2300x1720 792 1120 GV31464838 GV31464867

GVP-S50 50 kVA 42,5 kVA 900x1800x1420 900x2300x1720 859 1187 GV31464839 GV31464868

GVP-S66 66 kVA 60 kVA 900x1800x1420 900x2300x1720 890 1250 GV31464840 GV31464869

GVP-S72 72 kVA 65 kVA 900x1800x1420 900x2300x1720 945 1280 GV31464841 GV31464870

GVP-S88 88 kVA 80 kVA 1100x2100x1650 1100x2800x1830 955 1460 GV31464842 GV31464871

GVP-S110 110 kVA 100 kVA 1100x2100x1650 1100x2800x1830 1550 2235 GV31464843 GV31464872

GVP-S150 150 kVA 136 kVA 1100x2100x1650 1100x2800x1830 1600 2300 GV31464844 GV31464873

GVP-S165 165 kVA 150 kVA 1200x2800x1720 1200x2800x2220 2100 2750 GV31464845 GV31464874

GVP-S200 200 kVA 180 kVA 1200x2800x1720 1200x2800x2220 2115 2780 GV31464846 GV31464875

GVP-S220 220 kVA 208 kVA 1200x2800x1720 1200x2800x2220 2115 2780 GV31464847 GV31464876

GVP-S250 250 kVA 227 kVa 1500x2800x1720 1500x2800x2580 2120 3100 GV314617404 GV314617406

GVP-S275 275 kVA 250 kVA 1500x2800x1720 1500x2800x2580 2021 3006 GV31464848 GV31464877

GVP-S300 300 kVA 275 kVA 1500x3100x1960 1500x4200x2580 2900 4000 GV314617405 GV314617407

GVP-S400 400 kVA 350 kVA 1500x3100x1900 1500x4200x2580 3440 4400 GV31464849 GV31464878

GVP-S450 450 kVA 400 kVA 1500x3100x1900 1500x4200x2580 3520 4420 GV31464850 GV31464879

GVP-S500 500 kVA 455 kVA 1500x3500x2170 1500x4600x2810 3880 4780 GV31464851 GV31464880

GVP-S550 550 kVA 65 kVA 1500x3500x2170 1500x4600x2810 4070 5090 GV31464852 GV31464881

GVP-S660 660 kVA 600 kVA 1500x3500x2200 1500x4600x2810 4180 5090 GV31464853 GV31464882

GVP-S700 700 kVA 650 kVA 2100x3350x2200 2440x6060x2590 5070 7450 GV31464854 GV31464883

GVP-S825 825 kVA 750 kVA 2100x3350x2200 2440x6060x2590 6604 8414 GV31464855 GV31464884

GVP-S900 900 kVA 800 kVA 2100x3900x2220 2430x6050x2590 7264 9014 GV31464856 GV31464885

GVP-S1000 1000 kVA 900 kVA 2100x4650x2550 2430x6050x2590 9303 11053 GV314622841 GV314622842

GVP-S1100 1100 kVA 990 kVA 2100x4650x2550 2430x6050x2590 9610 11350 GV31464857 GV31464886

GVP-S1385 1385 kVA 1250 kVA 2100x4650x2550 2430x6050x2890 9720 15220 GV31464858 GV31464887

GVP-S1650 1650 kVA 1500 kVA 2400x5500x2690 2430x9080x3150 9920 16120 GV31464859 GV31464888

GVP-S1880 1880 kVA 1710 kVA 2400x5500x2690 2430x12190x3220 10700 19280 GV31464860 GV31464889

GVP-S2000 2000 kVA 1850 kVA 2430x6500x2690 3000x12190x3220 12145 20400 GV31464861 GV31464890

GVP-S2250 2250 kVA 2025 kVA 2430x6500x2690 3000x12190x3220 12350 20600 GV31464862 GV31464891

GVP-S2500 2500 kVA 2250 kVA 2430x6500x2690 3000x12190x3220 16300 20900 GV31464863 GV31464892

35

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power10 kVA

8 KW

Prime Power9 kVA

7,2 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 403A-11G1

No of Cylinder / Configuration 3 / IN LINE

Displacement (lt) 1,1

Bore / Stroke (mm) 77 / 81

Cycle 4

Compression Ratio 23 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 5,2

Lubrication Oil Capacity (lt) 4,9

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 8,5

Fuel Consumption (lt/h)100% 2,6

50% 2

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model PIO44E

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %80,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 930x2100x1000 850 100

OPEN SET 800x2000x1200 650 100

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S10 DIESEL GENERATOR SET / 50Hz

36

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power15 kVA

12 KW

Prime Power13 kVA

10,4 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 403A-15G1

No of Cylinder / Configuration 3 / IN LINE

Displacement (lt) 1,5

Bore / Stroke (mm) 84 / 90

Cycle 4

Compression Ratio 22.5 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 6

Lubrication Oil Capacity (lt) 6

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 12

Fuel Consumption (lt/h)100% 3,6

50% 2

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model PIO44F

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %82,1

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 930x2100x1000 850 100

OPEN SET 800x2000x1200 650 100

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S15 DIESEL GENERATOR SET / 50Hz

37

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power22 kVA

17,6 KW

Prime Power20 kVA

16 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 404A-22G1

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 2,2

Bore / Stroke (mm) 84 / 100

Cycle 4

Compression Ratio 23.3 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 7

Lubrication Oil Capacity (lt) 10,6

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 18,5

Fuel Consumption (lt/h)100% 5,3

50% 2,9

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model PIO144D

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %85,1

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 930x2100x1000 850 100

OPEN SET 800x2000x1200 650 100

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S22 DIESEL GENERATOR SET / 50Hz

38

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power33 kVA

26,4 KW

Prime Power30 kVA

24 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1103A-33G

No of Cylinder / Configuration 3 / IN LINE

Displacement (lt) 3,3

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 19.25 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 10,2

Lubrication Oil Capacity (lt) 8,3

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 27,7

Fuel Consumption (lt/h)100% 7,1

50% 4,06

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model PIO144G

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %86,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 950x2300x1720 1120 100

OPEN SET 900x1800x1420 790 100

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S33 DIESEL GENERATOR SET / 50Hz

39

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power50 kVA

40 KW

Prime Power45 kVA

36 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1103A-33TG1

No of Cylinder / Configuration 3 / IN LINE

Displacement (lt) 3,3

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 17.25 :1

Aspiration Turbo

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 10,2

Lubrication Oil Capacity (lt) 8,3

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 41,3

Fuel Consumption (lt/h)100% 10,8

50% 5,83

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model UCI224D

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %88,2

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 900x2300x1720 1180 150

OPEN SET 900x1800x1420 860 150

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S50 DIESEL GENERATOR SET / 50Hz

40

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power66 kVA

52,8 KW

Prime Power60 kVA

48 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1103A-33TG2

No of Cylinder / Configuration 3 / IN LINE

Displacement (lt) 3,3

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 17.25 :1

Aspiration Turbo

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 10,2

Lubrication Oil Capacity (lt) 7,9

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 53,8

Fuel Consumption (lt/h)100% 14,6

50% 7,56

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model UCI224E

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %88,2

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 900x2300x1720 1250 150

OPEN SET 900x1800x1420 890 150

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVZP-S66 DIESEL GENERATOR SET / 50Hz

41

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power72 kVA

57,6 KW

Prime Power65 kVA

52 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1104A-44TG1

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,4

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 17.25 :1

Aspiration Turbo

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 13

Lubrication Oil Capacity (lt) 8

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 58,4

Fuel Consumption (lt/h)100% 14,8

50% 8

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model UCI224F

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %89,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 900x2300x1720 1280 270

OPEN SET 900x1800x1420 945 270

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S72 DIESEL GENERATOR SET / 50Hz

42

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power88 kVA

70,4 KW

Prime Power80 kVA

64 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1104A-44TG2

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,4

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 17.25: 1

Aspiration Turbo

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 13

Lubrication Oil Capacity (lt) 8

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 71

Fuel Consumption (lt/h)100% 18,7

50% 9,7

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model UCI224G

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %90,2

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1100x2800x1830 1460 270

OPEN SET 1100x2100x1650 955 270

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S88 DIESEL GENERATOR SET / 50Hz

43

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power110 kVA

88 KW

Prime Power100 kVA

80 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1104C-44TAG2

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,4

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 18.2 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 12,6

Lubrication Oil Capacity (lt) 8

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 89

Fuel Consumption (lt/h)100% 22,6

50% 11,2

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model UCI274C

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %90,2

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1100x2800x1830 2235 270

OPEN SET 1100x2100x1650 1550 270

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S110 DIESEL GENERATOR SET / 50Hz

44

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power150 kVA

120 KW

Prime Power136 kVA

108,8 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1106A-70TG1

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6

Bore / Stroke (mm) 100 / 127

Cycle 4

Compression Ratio 17.0 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 37,2

Lubrication Oil Capacity (lt) 19

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 121

Fuel Consumption (lt/h)100% 31,5

50% 16,5

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model UCI274E

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %92,4

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1100x2800x1830 2300 400

OPEN SET 1100x2100x1650 1600 400

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S150 DIESEL GENERATOR SET / 50Hz

45

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power165 kVA

132 KW

Prime Power150 kVA

120 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1106A-70TAG2

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6

Bore / Stroke (mm) 100 / 127

Cycle 4

Compression Ratio 17.0 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 37,2

Lubrication Oil Capacity (lt) 19

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 133,2

Fuel Consumption (lt/h)100% 41

50% 20

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model UCI274F

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %91,7

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1200x2800x2220 2750 400

OPEN SET 1200x2800x1720 2100 400

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S165 DIESEL GENERATOR SET / 50Hz

46

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power200 kVA

160 KW

Prime Power180 kVA

144 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1106A-70TAG3

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,6

Bore / Stroke (mm) 105 / 127

Cycle 4

Compression Ratio 16.2 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 21

Lubrication Oil Capacity (lt) 16,5

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 158,4

Fuel Consumption (lt/h)100% 40,2

50% 20,5

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model UCI274G

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %92,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1200x2800x2220 2780 400

OPEN SET 1200x2800x1720 2115 400

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S200 DIESEL GENERATOR SET / 50Hz

47

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power220 kVA

176 KW

Prime Power200 kVA

160 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1106A-70TAG4

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 8,7

Bore / Stroke (mm) 116,6 / 135,9

Cycle 4

Compression Ratio 16.9 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 37,2

Lubrication Oil Capacity (lt) 28,3

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 174

Fuel Consumption (lt/h)100% 43,8

50% 26,4

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model UCI274H

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1200x2800x2220 2780 570

OPEN SET 1200x2800x1720 2115 570

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S220 DIESEL GENERATOR SET / 50Hz

48

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power250 kVA

200 KW

Prime Power227 kVA

182 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1506A-E87TAG2

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 8,7

Bore / Stroke (mm) 116,6 / 135,9

Cycle 4

Compression Ratio 16.9 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 37,2

Lubrication Oil Capacity (lt) 28,3

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 217

Fuel Consumption (lt/h)100% 54

50% 31

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model HC444E

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x2800x2580 3100 570

OPEN SET 1500x2800x1720 2120 570

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S250 DIESEL GENERATOR SET / 50Hz

49

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power275 kVA

220 KW

Prime Power250 kVA

200 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1506A-E87TAG3

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 8,7

Bore / Stroke (mm) 116,6 / 135,9

Cycle 4

Compression Ratio 16.9 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 37,2

Lubrication Oil Capacity (lt) 28,3

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 217

Fuel Consumption (lt/h)100% 54

50% 31

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model HC444E

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x2800x2580 3006 570

OPEN SET 1500x2800x1720 2021 570

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S275 DIESEL GENERATOR SET / 50Hz

50

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power300 kVA

240 KW

Prime Power275 kVA

220 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 1506A-E87TAG4

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 9,3

Bore / Stroke (mm) 117 / 146

Cycle 4

Compression Ratio 16.9 :1

Aspiration Turbo

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 33

Lubrication Oil Capacity (lt) 31

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 269

Fuel Consumption (lt/h)100% 71

50% 39

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model HCI444D

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4200x2580 4000 570

OPEN SET 1500x3100x1960 2900 570

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S300 DIESEL GENERATOR SET / 50Hz

51

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power400 kVA

320 KW

Prime Power350 kVA

280 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 2206C-E13TAG2

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 13

Bore / Stroke (mm) 137 / 157

Cycle 4

Compression Ratio 16.3 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 51,4

Lubrication Oil Capacity (lt) 40

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 305

Fuel Consumption (lt/h)100% 71

50% 37

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model HC444E

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4200x2580 4400 1000

OPEN SET 1500x3100x1900 3440 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S400 DIESEL GENERATOR SET / 50Hz

52

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power450 kVA

360 KW

Prime Power400 kVA

320 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 2206A-E13TAG3

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 13

Bore / Stroke (mm) 137 / 157

Cycle 4

Compression Ratio 16.3 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 51,4

Lubrication Oil Capacity (lt) 40

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 350

Fuel Consumption (lt/h)100% 81

50% 42

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model HC444F

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4200x2580 4420 1000

OPEN SET 1500x3100x1900 3520 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S450 DIESEL GENERATOR SET / 50Hz

53

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power500 kVA

400 KW

Prime Power455 kVA

364 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 2506A-E15TAG1

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 15

Bore / Stroke (mm) 137 / 171

Cycle 4

Compression Ratio 16.0 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 58

Lubrication Oil Capacity (lt) 62

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 396

Fuel Consumption (lt/h)100% 95

50% 50

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model HC544C

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4600x2810 4780 1000

OPEN SET 1500x3500x2170 3880 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S500 DIESEL GENERATOR SET / 50Hz

54

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power550 kVA

450 KW

Prime Power500 kVA

400 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 2506CA-E15TAG2

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 15

Bore / Stroke (mm) 137 / 171

Cycle 4

Compression Ratio 16.0 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 58

Lubrication Oil Capacity (lt) 62

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 435

Fuel Consumption (lt/h)100% 106

50% 55

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model HC544C

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4600x2810 5090 1000

OPEN SET 1500x3500x2170 4070 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S550 DIESEL GENERATOR SET / 50Hz

55

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power660 kVA

528 KW

Prime Power600 kVA

480 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 2806A-E18TAG1A

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 18

Bore / Stroke (mm) 145 / 183

Cycle 4

Compression Ratio 14.5 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 61

Lubrication Oil Capacity (lt) 62

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 522

Fuel Consumption (lt/h)100% 122

50% 61

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model HCI544E

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,1

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4600x2810 5090 1500

OPEN SET 1500x3500x2200 4180 1500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S660 DIESEL GENERATOR SET / 50Hz

56

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power700 kVA

560 KW

Prime Power650 kVA

520 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 2806A-E18TAG2

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 18

Bore / Stroke (mm) 145 / 183

Cycle 4

Compression Ratio 14.5 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 61

Lubrication Oil Capacity (lt) 62

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 565

Fuel Consumption (lt/h)100% 125

50% 63

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model HC544F

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2440x6060x2590 7450 1500

OPEN SET 2100x3350x2200 5070 1500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S700 DIESEL GENERATOR SET / 50Hz

57

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power825 kVA

660 KW

Prime Power750 kVA

600 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4006-23TAG2A

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 23

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 105

Lubrication Oil Capacity (lt) 113,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 632

Fuel Consumption (lt/h)100% 161

50% 80

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model HCI634G

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2440x6060x2590 8414 1500

OPEN SET 2100x3350x2200 6604 1500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S825 DIESEL GENERATOR SET / 50Hz

58

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power900 kVA

720 KW

Prime Power800 kVA

640 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4006-23TAG3A

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 23

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 105

Lubrication Oil Capacity (lt) 113,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 679

Fuel Consumption (lt/h)100% 172

50% 90

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model HCI634G

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2590 9014 1500

OPEN SET 2100x3900x2220 7264 1500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S900 DIESEL GENERATOR SET / 50Hz

59

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1000 kVA

800 KW

Prime Power900 kVA

720 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4008-TAG1A

No of Cylinder / Configuration 8 / IN LINE

Displacement (lt) 30

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 143

Lubrication Oil Capacity (lt) 153

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 882

Fuel Consumption (lt/h)100% 195

50% 98

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model HCI 634H

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %95

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2590 11053 2000

OPEN SET 2100x4650x2550 9303 2000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S1000 DIESEL GENERATOR SET / 50Hz

60

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1100 kVA

880 KW

Prime Power990 kVA

792 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4008-TAG2A

No of Cylinder / Configuration 8 / IN LINE

Displacement (lt) 30

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 149

Lubrication Oil Capacity (lt) 153

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 861

Fuel Consumption (lt/h)100% 226

50% 130

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model HCI634J

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2590 11350 2000

OPEN SET 2100x4650x2550 9610 2000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S1100 DIESEL GENERATOR SET / 50Hz

61

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1385 kVA

1108 KW

Prime Power1250 kVA

1000 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4012-46TWG2A

No of Cylinder / Configuration 12 / V

Displacement (lt) 45

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 159

Lubrication Oil Capacity (lt) 201

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1055

Fuel Consumption (lt/h)100% 259

50% 143

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model PI734A

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2890 15220 EXTERNAL

OPEN SET 2100x4650x2550 9720 EXTERNAL

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S1385 DIESEL GENERATOR SET / 50Hz

62

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1650 kVA

1320 KW

Prime Power1500 kVA

1204 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4012-46TAG2A

No of Cylinder / Configuration 12 / V

Displacement (lt) 46

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.00 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 177

Lubrication Oil Capacity (lt) 240

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1267

Fuel Consumption (lt/h)100% 301

50% 165

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model PI734C

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0.5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x9080x3150 16120 EXTERNAL

OPEN SET 2400x5500x2690 9920 EXTERNAL

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S1650 DIESEL GENERATOR SET / 50Hz

63

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1880 kVA

1504 KW

Prime Power1710 kVA

1368 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4012-46TAG3A

No of Cylinder / Configuration 12 / V

Displacement (lt) 46

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 177

Lubrication Oil Capacity (lt) 210

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1440

Fuel Consumption (lt/h)100% 370

50% 187

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model PI734E

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x12190x3220 19280 EXTERNAL

OPEN SET 2400x5500x2690 10700 EXTERNAL

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S1880 DIESEL GENERATOR SET / 50Hz

64

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power2000 kVA

1622 KW

Prime Power1850 kVA

1476 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4016-TAG1A

No of Cylinder / Configuration 16 / V

Displacement (lt) 46

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 237,2

Lubrication Oil Capacity (lt) 316

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1537

Fuel Consumption (lt/h)100% 370

50% 191

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model PI734E

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 3000x12190x3220 20400 EXTERNAL

OPEN SET 2430x6500x2690 12145 EXTERNAL

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S2000 DIESEL GENERATOR SET / 50Hz

65

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power2250 kVA

1800 KW

Prime Power2025 kVA

1620 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4016-TAG2A

No of Cylinder / Configuration 16 / V

Displacement (lt) 46

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 237,2

Lubrication Oil Capacity (lt) 316

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1715

Fuel Consumption (lt/h)100% 421

50% 217

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model PI734G

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 3000x12190x3220 20600 EXTERNAL

OPEN SET 2430x6500x2690 12350 EXTERNAL

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP-S2250 DIESEL GENERATOR SET / 50Hz

66

www.grandvoltage.roPERKINS – STAMFORD

OUTPUT RATINGS 50 HZ / 400 V

Standby Power2500 kVA

2000 KW

Prime Power2250 kVA

1800 KW

ENGINE (ESP -STAND-BY)

Manufacturer PERKINS

Origin UK

Model 4016-61TRG3

No of Cylinder / Configuration 16 / V

Displacement (lt) 61.123

Bore / Stroke (mm) 160 / 190

Cycle 4

Compression Ratio 13.6 :1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 270

Lubrication Oil Capacity (lt) 237

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1975

Fuel Consumption (lt/h)100% 470

50% 234

ALTERNATOR

Manufacturer STAMFORD

Origin UK

Model N/A

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 3000x12190x3220 20900 EXTERNAL

OPEN SET 2430x6500x2690 16300 EXTERNAL

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVP--S2500 DIESEL GENERATOR SET / 50Hz

67

Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code

OpenOrder Code

CanopiedSTAND-BY POWER

PRIME POWER

OPEN CANOPIED OPEN CANOPIED

GVDO-G220 220 kVA 200 kVA 1150x2690x1620 1220x3400x1940 1800 2175 GV31464893 GV31464904

GVDO-G275 275 kVA 250 kVA 1300x3020x1600 1360x3960x2100 2265 2950 GV31464894 GV31464905

GVDO-G330 330 kVA 300 kVA 1300x2950x1588 1360x3960x2100 2375 3065 GV31464895 GV31464906

GVDO-G410 410 kVA 375 kVA 1550x3030x1994 1610x4460x2480 3030 4024 GV31464896 GV31464907

GVDO-G490 485 kVA 425 kVA 1550x3110x1994 1610x4460x2480 3130 4150 GV31464897 GV31464908

GVDO-G510 510 kVA 460 kVA 1550x3110x1994 1610x4460x2480 3080 4100 GV31464898 GV31464909

GVDO-G580 580 kVA 525 kVA 1550x3110x1990 1610x4460x2480 3350 4200 GV31464899 GV31464910

GVDO-G630 630 kVA 575 kVA 1550x3260x2060 1610x4810x2620 3720 4835 GV31464900 GV31464911

GVDO-G710 710 kVA 640 kVA 1550x3360x2060 1610x4810x2620 4000 4940 GV31464901 GV31464912

GVDO-G750 750 kVA 680 kVA 1550x3494x2301 1610x5300x2660 4190 5400 GV31464902 GV31464913

GVDO-G825 825 kVA 750 kVA 1550x3630x2301 1610x5300x2660 4320 5535 GV31464903 GV31464914

68

www.grandvoltage.roDOOSAN – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power220 kVA

176 KW

Prime Power200 kVA

160 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model P086TI

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 8,07

Bore / Stroke (mm) 111 / 139

Cycle 4

Compression Ratio 16,4. :1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 46

Lubrication Oil Capacity (lt) 15,5

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 199

Fuel Consumption (lt/h)100% 43,1

50% 21,1

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-220

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1220x3400x1940 2175 380

OPEN SET 1150x2690x1620 1800 380

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G220 DIESEL GENERATOR SET / 50Hz

69

www.grandvoltage.roDOOSAN – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power275 kVA

220 KW

Prime Power250 kVA

200 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model P126TI

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 11,05

Bore / Stroke (mm) 123 / 155

Cycle 4

Compression Ratio 17.1 :1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 52

Lubrication Oil Capacity (lt) 23

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 272

Fuel Consumption (lt/h)100% 53,3

50% 27,5

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-275

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1360x3960x2100 2940 470

OPEN SET 1300x3020x1600 2265 450

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G275 DIESEL GENERATOR SET / 50Hz

70

www.grandvoltage.roDOOSAN – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power330 kVA

264 KW

Prime Power300 kVA

240 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model P126TI-II

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 11,05

Bore / Stroke (mm) 123 / 155

Cycle 4

Compression Ratio 17.1 :1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 52

Lubrication Oil Capacity (lt) 23

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 294

Fuel Consumption (lt/h)100% 63,1

50% 31,3

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-330

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,8

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1360x3960x2100 3065 470

OPEN SET 1300x2950x1588 2375 450

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G330 DIESEL GENERATOR SET / 50Hz

71

www.grandvoltage.roDOOSAN – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power410 kVA

328 KW

Prime Power375 kVA

300 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model P158LE-1

No of Cylinder / Configuration 8 / V TYPE

Displacement (lt) 14,60

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0 :1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 68,5

Lubrication Oil Capacity (lt) 21

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 362

Fuel Consumption (lt/h)100% 78,7

50% 40

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-430

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x4460x2480 4024 700

OPEN SET 1550x3030x1994 3030 700

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G410 DIESEL GENERATOR SET / 50Hz

72

www.grandvoltage.roDOOSAN – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power485 kVA

388 KW

Prime Power425 kVA

340 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model P158LE

No of Cylinder / Configuration 8 / V TYPE

Displacement (lt) 14,60

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 68,5

Lubrication Oil Capacity (lt) 21

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 414

Fuel Consumption (lt/h)100% 89,3

50% 43,9

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-500

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x4460x2480 4150 700

OPEN SET 1550x3110x1994 3130 700

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G490 DIESEL GENERATOR SET / 50Hz

73

www.grandvoltage.roDOOSAN – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power510 kVA

408 KW

Prime Power460 kVA

368 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model DP158LC

No of Cylinder / Configuration 8 / V TYPE

Displacement (lt) 14,618

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 90

Lubrication Oil Capacity (lt) 22

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 449

Fuel Consumption (lt/h)100% 99,6

50% 48,9

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-550

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x4460x2480 4100 700

OPEN SET 1550x3110x1994 3080 700

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G510 DIESEL GENERATOR SET / 50Hz

74

www.grandvoltage.roDOOSAN – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power580 kVA

464 KW

Prime Power525 kVA

420 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model DP158LD

No of Cylinder / Configuration 8 / V TYPE

Displacement (lt) 14,61

Bore / Stroke (mm) 128 / 142

Cycle 4

Compression Ratio 15.0:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 90

Lubrication Oil Capacity (lt) 22

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 510

Fuel Consumption (lt/h)100% 115,1

50% 55,1

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-600

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x4460x2480 4200 850

OPEN SET 1550x3110x1990 3030 850

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G580 DIESEL GENERATOR SET / 50Hz

75

www.grandvoltage.roDOOSAN – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power630 kVA

504 KW

Prime Power575 kVA

460 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model DP180LA

No of Cylinder / Configuration 10 / V TYPE

Displacement (lt) 18,273

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0 :1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 112,2

Lubrication Oil Capacity (lt) 34

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 552

Fuel Consumption (lt/h)100% 123,6

50% 64,8

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-660

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x4810x2620 4835 850

OPEN SET 1550x3260x2060 3720 850

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G630 DIESEL GENERATOR SET / 50Hz

76

www.grandvoltage.roDOOSAN – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power710 kVA

568 KW

Prime Power640 kVA

512 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model DP180LB

No of Cylinder / Configuration 10 / V TYPE

Displacement (lt) 18,273

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 112

Lubrication Oil Capacity (lt) 34

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 612

Fuel Consumption (lt/h)100% 136,4

50% 71,2

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-750

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x4810x2620 4940 850

OPEN SET 1550x3360x2060 4000 850

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G710 DIESEL GENERATOR SET / 50Hz

77

www.grandvoltage.roDOOSAN – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power750 kVA

600 KW

Prime Power680 kVA

544 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model DP222LB

No of Cylinder / Configuration 12 / V TYPE

Displacement (lt) 21,93

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 134,8

Lubrication Oil Capacity (lt) 40

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 664

Fuel Consumption (lt/h)100% 147

50% 73

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-750

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x5300x2660 5400 1000

OPEN SET 1550x3494x2301 4190 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G750 DIESEL GENERATOR SET / 50Hz

78

www.grandvoltage.roDOOSAN – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power825 kVA

660 KW

Prime Power750 kVA

600 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model DP222LC

No of Cylinder / Configuration 12 / V TYPE

Displacement (lt) 21,93

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 134,8

Lubrication Oil Capacity (lt) 40

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 723

Fuel Consumption (lt/h)100% 161

50% 79,3

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-850

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x5300x2660 5535 1000

OPEN SET 1550x3630x2301 4320 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G825 DIESEL GENERATOR SET / 50Hz

79

GVDO-M220 220 kVA 200 kVA 1150x2688x1624 1217x3400x1938 1800 2175 GV31464915 GV31464926

GVDO-M275 275 kVA 250 kVA 1300x3020x1600 1360x3960x2100 2265 2950 GV31464916 GV31464927

GVDO-M330 330 kVA 300 kVA 1300x2950x1588 1360x3960x2100 2375 3065 GV31464917 GV31464928

GVDO-M410 410 kVA 375 kVA 1550x3030x1994 1610x4460x2480 3030 4024 GV31464918 GV31464929

GVDO-M490 485 kVA 425 kVA 1550x3110x1994 1610x4460x2480 3130 4150 GV31464919 GV31464930

GVDO-M510 510 kVA 460 kVA 1550x3110x1994 1610x4460x2480 3080 4100 GV31464920 GV31464931

GVDO-M580 580 kVA 525 kVA 1550x3110x1990 1610x4460x2480 3030 4200 GV31464921 GV31464932

GVDO-M630 630 kVA 575 kVA 1550x3260x2060 1610x4810x2620 3720 4835 GV31464922 GV31464933

GVDO-M710 710 kVA 640 kVA 1550x3360x2060 1610x4810x2620 4000 4940 GV31464923 GV31464934

GVDO-M750 750 kVA 680 kVA 1550x3494x2301 1610x5300x2660 4190 5400 GV31464924 GV31464935

GVDO-M825 825 kVA 750 kVA 1550x3630x2301 1610x5300x2660 4320 5535 GV31464925 GV31464936

Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code

OpenOrder Code

CanopiedSTAND-BY POWER

PRIME POWER

OPEN CANOPIED OPEN CANOPIED

80

www.grandvoltage.roDOOSAN – MECCALTE

OUTPUT RATINGS 50 HZ / 400 V

Standby Power220 kVA

176 KW

Prime Power200 kVA

160 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model P086TI

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 8,07

Bore / Stroke (mm) 111 / 139

Cycle 4

Compression Ratio 16,4. :1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 46

Lubrication Oil Capacity (lt) 15,5

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 199

Fuel Consumption (lt/h)100% 43,1

50% 21,1

ALTERNATOR

Manufacturer MECC ALTE

Origin ITALY

Model ECO 38 2SN/4

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1220x3400x1940 2175 380

OPEN SET 1150x2690x1620 1800 380

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-M220 DIESEL GENERATOR SET / 50Hz

81

www.grandvoltage.roDOOSAN – MECCALTE

OUTPUT RATINGS 50 HZ / 400 V

Standby Power275 kVA

220 KW

Prime Power250 kVA

200 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model P126TI

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 11,05

Bore / Stroke (mm) 123 / 155

Cycle 4

Compression Ratio 17.1 :1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 52

Lubrication Oil Capacity (lt) 23

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 272

Fuel Consumption (lt/h)100% 53,3

50% 27,5

ALTERNATOR

Manufacturer MECC ALTE

Origin ITALY

Model ECO 38-1LN

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1360x3960x2100 2950 470

OPEN SET 1300x3020x1600 2265 450

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-M275 DIESEL GENERATOR SET / 50Hz

82

www.grandvoltage.roDOOSAN – MECCALTE

OUTPUT RATINGS 50 HZ / 400 V

Standby Power330 kVA

264 KW

Prime Power300 kVA

240 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model P126TI-II

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 11,05

Bore / Stroke (mm) 123 / 155

Cycle 4

Compression Ratio 17.1 :1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 52

Lubrication Oil Capacity (lt) 23

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 294

Fuel Consumption (lt/h)100% 63,1

50% 31,3

ALTERNATOR

Manufacturer MECC ALTE

Origin ITALY

Model ECO 38-2LN/4

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,8

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1360x3960x2100 3065 470

OPEN SET 1300x2950x1588 2375 450

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-M330 DIESEL GENERATOR SET / 50Hz

83

www.grandvoltage.roDOOSAN – MECCALTE

OUTPUT RATINGS 50 HZ / 400 V

Standby Power410 kVA

328 KW

Prime Power375 kVA

300 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model P158LE-1

No of Cylinder / Configuration 8 / V TYPE

Displacement (lt) 14,60

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 68,5

Lubrication Oil Capacity (lt) 21

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 362

Fuel Consumption (lt/h)100% 78,7

50% 40

ALTERNATOR

Manufacturer MECC ALTE

Origin ITALY

Model ECO 40-1S/4

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x4460x2480 4024 700

OPEN SET 1550x3030x1994 3030 700

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-M410 DIESEL GENERATOR SET / 50Hz

84

www.grandvoltage.roDOOSAN – MECCALTE

OUTPUT RATINGS 50 HZ / 400 V

Standby Power485 kVA

388 KW

Prime Power425 kVA

340 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model P158LE

No of Cylinder / Configuration 8 / V TYPE

Displacement (lt) 14,60

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0 :1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 68,5

Lubrication Oil Capacity (lt) 21

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 414

Fuel Consumption (lt/h)100% 89,3

50% 43,9

ALTERNATOR

Manufacturer MECC ALTE

Origin ITALY

Model ECO 40-2S/4

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x4460x2480 4150 700

OPEN SET 1550x3110x1994 3130 700

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-M490 DIESEL GENERATOR SET / 50Hz

85

www.grandvoltage.roDOOSAN – MECCALTE

OUTPUT RATINGS 50 HZ / 400 V

Standby Power510 kVA

408 KW

Prime Power460 kVA

368 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model DP158LC

No of Cylinder / Configuration 8 / V TYPE

Displacement (lt) 14,618

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 90

Lubrication Oil Capacity (lt) 22

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 449

Fuel Consumption (lt/h)100% 99,6

50% 48,9

ALTERNATOR

Manufacturer MECC ALTE

Origin ITALY

Model ECO 40-3S/4

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x4460x2480 4100 700

OPEN SET 1550x3110x1994 3080 700

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G510 DIESEL GENERATOR SET / 50Hz

86

www.grandvoltage.roDOOSAN – MECCALTE

OUTPUT RATINGS 50 HZ / 400 V

Standby Power580 kVA

464 KW

Prime Power525 kVA

420 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model DP158LD

No of Cylinder / Configuration 8 / V TYPE

Displacement (lt) 14,61

Bore / Stroke (mm) 128 / 142

Cycle 4

Compression Ratio 15.0:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 90

Lubrication Oil Capacity (lt) 22

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 510

Fuel Consumption (lt/h)100% 115,1

50% 55,1

ALTERNATOR

Manufacturer MECC ALTE

Origin ITALY

Model ECO 40-1L/4

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x4460x2480 4200 850

OPEN SET 1550x3110x1990 3030 850

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G580 DIESEL GENERATOR SET / 50Hz

87

www.grandvoltage.roDOOSAN – MECCALTE

OUTPUT RATINGS 50 HZ / 400 V

Standby Power630 kVA

504 KW

Prime Power575 kVA

460 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model DP180LA

No of Cylinder / Configuration 10 / V TYPE

Displacement (lt) 18,273

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 112,2

Lubrication Oil Capacity (lt) 34

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 552

Fuel Consumption (lt/h)100% 123,6

50% 64,8

ALTERNATOR

Manufacturer MECC ALTE

Origin ITALY

Model ECO 40-1,5L/4

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,8

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x4810x2620 4835 850

OPEN SET 1550x3260x2060 3720 850

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G630 DIESEL GENERATOR SET / 50Hz

88

www.grandvoltage.roDOOSAN – MECCALTE

OUTPUT RATINGS 50 HZ / 400 V

Standby Power710 kVA

568 KW

Prime Power640 kVA

512 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model DP180LB

No of Cylinder / Configuration 10 / V TYPE

Displacement (lt) 18,273

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 112

Lubrication Oil Capacity (lt) 34

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 612

Fuel Consumption (lt/h)100% 136,4

50% 71,2

ALTERNATOR

Manufacturer MECC ALTE

Origin ITALY

Model ECO 40-2L/4

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,8

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x4810x2620 4940 850

OPEN SET 1550x3360x2060 4000 850

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G710 DIESEL GENERATOR SET / 50Hz

89

www.grandvoltage.roDOOSAN – MECCALTE

OUTPUT RATINGS 50 HZ / 400 V

Standby Power750 kVA

600 KW

Prime Power680 kVA

544 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model DP222LB

No of Cylinder / Configuration 12 / V TYPE

Displacement (lt) 21,93

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 134,8

Lubrication Oil Capacity (lt) 40

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 664

Fuel Consumption (lt/h)100% 147

50% 73

ALTERNATOR

Manufacturer MECC ALTE

Origin ITALY

Model ECO 40-2L/4

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x5300x2660 5400 1000

OPEN SET 1550x3494x2301 4190 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G750 DIESEL GENERATOR SET / 50Hz

90

www.grandvoltage.roDOOSAN – MECCALTE

OUTPUT RATINGS 50 HZ / 400 V

Standby Power825 kVA

660 KW

Prime Power750 kVA

600 KW

ENGINE (ESP -STAND-BY)

Manufacturer DOOSAN

Origin SOUTH KOREA

Model DP222LC

No of Cylinder / Configuration 12 / V TYPE

Displacement (lt) 21,93

Bore / Stroke (mm) 128 / 142

Cycle 4 1

Compression Ratio 5.0:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 134,8

Lubrication Oil Capacity (lt) 40

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 723

Fuel Consumption (lt/h)100% 161

50% 79,3

ALTERNATOR

Manufacturer MECC ALTE

Origin ITALY

Model ECO 40-VL/4

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1610x5300x2660 5535 1000

OPEN SET 1550x3630x2301 4320 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVDO-G825 DIESEL GENERATOR SET / 50Hz

91

Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code

CodeOrder Code

CanopiedSTAND-BY POWER

PRIME POWER

OPEN CANOPIED OPEN CANOPIED

GVR-T20 20 kVA 18 kVA 650x1400x1300 900x2200x1500 400 460 GV31464939 GV31464955

GVR-T25 25 kVA 22 kVA 650x1400x1300 900x2200x1500 450 750 GV31464940 GV31464956

GVR-T40 40 kVA 36 kVA 920x1700x1200 920x2100x1350 650 960 GV31464941 GV31464957

GVR-T50 50 kVA 45 kVA 950x1700x1450 950x2440x1620 850 1150 GV31464942 GV31464958

GVR-T55 55 kVA 50 kVA 950x1700x1450 950x2250x1600 850 1150 GV31464943 GV31464959

GVR-T75 75 kVA 68 kVA 950x1700x1450 950x2440x1620 950 1250 GV31464944 GV31464960

GVR-T90 90 kVA 81 kVA 950x1900x1500 950x2450x1650 1120 1470 GV31464945 GV31464961

GVR-T110 110 kVA 100 kVA 1100x2200x1700 1100x3000x1800 1450 1970 GV31464946 GV31464962

GVR-T125 125 kVA 113 kVA 1100x2200x1700 1100x3000x1800 1520 2040 GV31464947 GV31464963

GVR-T150 150 kVA 136 kVA 1100x2200x1700 1100x3000x1800 1680 2220 GV31464948 GV31464964

GVR-T175 175 kVA 158 kVA 1100x2200x1700 1100x2980x1860 1500 1850 GV31464949 GV31464965

GVR-T220 220 kVA 200 kVA 1100x2500x1700 1100x3400x1960 1700 2200 GV31464950 GV31464966

GVR-T306 306 kVA 275 kVA 1250x3000x1800 1250x3980x2060 2500 2850 GV31464951 GV31464967

GVR-T330 330 kVA 296 kVA 1250x3000x1800 1250x3980x2060 2600 3050 GV31464952 GV31464968

92

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power20 kVA

16 KW

Prime Power18 kVA

14 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R485

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 2,156

Bore / Stroke (mm) 80 / 95

Cycle 4

Compression Ratio 18.00 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 16

Lubrication Oil Capacity (lt) 8

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 13

Fuel Consumption (lt/h)100% 4,19

50% 2,72

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-20

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %86

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 900x2200x1500 460 120

OPEN SET 650x1400x1300 400 120

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T20 DIESEL GENERATOR SET / 50Hz

93

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power25 kVA

20 KW

Prime Power22 kVA

17,5 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R490

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 2,545

Bore / Stroke (mm) 95 / 100

Cycle 4

Compression Ratio 18.00 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 16

Lubrication Oil Capacity (lt) 8

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 21

Fuel Consumption (lt/h)100% 5,20

50% 3,38

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-25

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %86

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 900x2200x1500 750 120

OPEN SET 650x1400x1300 450 120

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T25 DIESEL GENERATOR SET / 50Hz

94

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power40 kVA

32 KW

Prime Power36 kVA

28,8 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R4100D

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 3,93

Bore / Stroke (mm) 100 / 125

Cycle 4

Compression Ratio 19.00 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 18

Lubrication Oil Capacity (lt) 12

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 33

Fuel Consumption (lt/h)100% 7,90

50% 5,14

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-40

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %88

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 950x2100x1350 960 200

OPEN SET 950x1800x1400 740 200

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T40 DIESEL GENERATOR SET / 50Hz

95

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power50 kVA

40 KW

Prime Power45 kVA

36 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R4100ZD

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 3,93

Bore / Stroke (mm) 100 / 125

Cycle 4

Compression Ratio 17.00 :1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 18

Lubrication Oil Capacity (lt) 12

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 42

Fuel Consumption (lt/h)100% 9,88

50% 6,42

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-50

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,8

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 950x2440x1620 1050 200

OPEN SET 950x1800x1400 820 200

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T50 DIESEL GENERATOR SET / 50Hz

96

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power55 kVA

44 KW

Prime Power50 kVA

40 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R4105D

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,33

Bore / Stroke (mm) 105 / 125

Cycle 4

Compression Ratio 17.00 :1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 21

Lubrication Oil Capacity (lt) 14

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 48

Fuel Consumption (lt/h)100% 10,87

50% 7,06

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-55

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,8

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 950x2440x1620 1230 200

OPEN SET 950x1800x1400 910 200

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T55 DIESEL GENERATOR SET / 50Hz

97

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power75 kVA

60 KW

Prime Power68 kVA

54 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R4105ZD

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,33

Bore / Stroke (mm) 105 / 125

Cycle 4

Compression Ratio 16.00 :1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 21

Lubrication Oil Capacity (lt) 14

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 56

Fuel Consumption (lt/h)100% 14,82

50% 9,63

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-75

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %91

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 950x2440x1620 1290 200

OPEN SET 950x1800x1500 950 200

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T75 DIESEL GENERATOR SET / 50Hz

98

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power90 kVA

72 KW

Prime Power81 kVA

64 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R4105IZLD

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,5

Bore / Stroke (mm) 105 / 130

Cycle 4

Compression Ratio 16.00 :1

Aspiration Turbocharged

Governor Type Mechanic

Cooling System Water

Coolant Capacity (lt) 24

Lubrication Oil Capacity (lt) 14

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 66

Fuel Consumption (lt/h)100% 17,78

50% 11,56

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-90

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %91

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 980x2750x1650 1390 240

OPEN SET 950x1900x1500 1120 240

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T90 DIESEL GENERATOR SET / 50Hz

99

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power110 kVA

88 KW

Prime Power100 kVA

80 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R6105AZLD

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,49

Bore / Stroke (mm) 105 / 125

Cycle 4

Compression Ratio 16.00 :1

Aspiration Turbocharged

Governor Type Mechanic

Cooling System Water

Coolant Capacity (lt) 23

Lubrication Oil Capacity (lt) 18

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 96,8

Fuel Consumption (lt/h)100% 21.2

50% 13,5

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-110

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,8

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1100x2800x1860 1715 340

OPEN SET 1100x2200x1700 1400 340

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T110 DIESEL GENERATOR SET / 50Hz

100

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power125 kVA

100 KW

Prime Power113 kVA

90 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R6105AZLD

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,75

Bore / Stroke (mm) 105 / 130

Cycle 4

Compression Ratio 16.00 :1

Aspiration Turbocharged

Governor Type Mechanic

Cooling System Water

Coolant Capacity (lt) 27

Lubrication Oil Capacity (lt) 18

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 121

Fuel Consumption (lt/h)100% 23,31

50% 15,15

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-135

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,8

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1100x2980x1860 1750 340

OPEN SET 1100x2200x1700 1400 340

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T125 DIESEL GENERATOR SET / 50Hz

101

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power150 kVA

120 KW

Prime Power136 kVA

108 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R6105AZLD

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,75

Bore / Stroke (mm) 105 / 130

Cycle 4

Compression Ratio 16.00 :1

Aspiration Turbocharged

Governor Type Mechanic

Cooling System Water

Coolant Capacity (lt) 27

Lubrication Oil Capacity (lt) 18

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 121

Fuel Consumption (lt/h) 100% 27,97

50% 18,18

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-150

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1100x2980x1860 1780 340

OPEN SET 1100x2200x1700 1450 340

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T150 DIESEL GENERATOR SET / 50Hz

102

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power175 kVA

140 KW

Prime Power158 kVA

126 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R6105IZLD

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 7,01

Bore / Stroke (mm) 105 / 135

Cycle 4

Compression Ratio 16.00 :1

Aspiration Turbocharged

Governor Type Mechanic

Cooling System Water

Coolant Capacity (lt) 27

Lubrication Oil Capacity (lt) 19

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 145,2

Fuel Consumption (lt/h)100% 30,76

50% 20

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-175

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1100x3200x1860 1825 340

OPEN SET 1100x2200x1700 1500 340

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T175 DIESEL GENERATOR SET / 50Hz

103

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power220 kVA

176 KW

Prime Power200 kVA

160 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R6113AZLD

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 7,52

Bore / Stroke (mm) 113 / 125

Cycle 4

Compression Ratio 16.00 :1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 35

Lubrication Oil Capacity (lt) 22

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 175

Fuel Consumption (lt/h)100% 41,02

50% 26,66

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-220

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,8

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1100x3400x1960 2200 400

OPEN SET 1100x2500x1700 1700 400

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T220 DIESEL GENERATOR SET / 50Hz

104

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power306 kVA

245 KW

Prime Power275 kVA

220 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R6126ZLD4

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 9,7

Bore / Stroke (mm) 126 / 130

Cycle 4

Compression Ratio 17.00 :1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 50

Lubrication Oil Capacity (lt) 19

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 235

Fuel Consumption (lt/h)100% 54,44

50% 35,38

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-330

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1250x3980x2060 2950 500

OPEN SET 1250x3000x1800 2500 500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T306 DIESEL GENERATOR SET / 50Hz

105

www.grandvoltage.roRICARDO T – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power330 kVA

264 KW

Prime Power296 kVA

237 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model R6126ZLD5

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 9,7

Bore / Stroke (mm) 126 / 130

Cycle 4

Compression Ratio 17.00 :1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 50

Lubrication Oil Capacity (lt) 19

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 269,5

Fuel Consumption (lt/h)100% 58,71

50% 38,16

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-330

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1250x3980x2060 3050 500

OPEN SET 1250x3000x1800 2600 500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-T330 DIESEL GENERATOR SET / 50Hz

106

Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code

OpenOrder Code

CanopiedSTAND-BY POWER

PRIME POWER

OPEN CANOPIED OPEN CANOPIED

GVV-G110 110 kVA 100 kVA 1100x2200x1700 1100x3000x1800 1550 2050 GV31464969 GV31464984

GVV-G145 145 kVA 130 kVA 1094x3200x1600 1260x3350x1920 1535 1995 GV31464970 GV31464985

GVV-G165 165 kVA 150 kVA 1110x3200x1920 1260x3350x1910 2150 2950 GV31464971 GV31464986

GVV-G200 200 kVA 180 kVA 1094x2570x1765 1110x3950x2170 2400 3150 GV31464972 GV31464987

GVV-G220 220 kVA 200 kVA 1094x2570x1765 1110x3950x2170 2550 3330 GV31464973 GV31464988

GVV-G275 275 kVA 250 kVA 1094x2570x1765 1110x3950x2170 2700 3450 GV31464974 GV31464989

GVV-G330 330 kVA 300 kVA 1260x3200x1920 1285x4450x2120 2920 3595 GV31464975 GV31464990

GVV-G385 385 kVA 326 kVA 1260x3200x1920 1285x4450x2120 3010 3720 GV31464976 GV31464991

GVV-G414 414 kVA 378 kVA 1260x3200x1920 1285x4450x2120 2915 3625 GV31464977 GV31464992

GVV-G440 440 kVA 400 kVA 1260x3200x1920 1285x4450x2120 3115 3825 GV31464978 GV31464993

GVV-G500 500 kVA 455 kVA 1370x3500x2180 1400x4810x2390 3640 4640 GV31464980 GV31464995

GVV-G550 550 kVA 500 kVA 1370x3500x2180 1400x4810x2390 3685 4645 GV31464981 GV31464996

GVV-G650 650 kVA 590 kVA 1670x3500x2235 1700x4820x2600 4219 5326 GV31464982 GV31464997

GVV-G700 695 kVA 630 kVA 1670x3500x2235 1700x4820x2600 4439 5516 GV31464983 GV31464998

107

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power110 kVA

88 KW

Prime Power100 kVA

80 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TAD531GE

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,76

Bore / Stroke (mm) 108 / 130

Cycle 4

Compression Ratio 18:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 19,7

Lubrication Oil Capacity (lt) 13

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 88

Fuel Consumption (lt/h)100% 19,5

50% 9,8

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT 110

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %92

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1100x3000x1800 2050 240

OPEN SET 1100x2200x1700 1550 240

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G110 DIESEL GENERATOR SET / 50Hz

108

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power145 kVA

116 KW

Prime Power130 kVA

104 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TAD532GE EDC4

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 7,15

Bore / Stroke (mm) 108 / 130

Cycle 4

Compression Ratio 17.5:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 23,8

Lubrication Oil Capacity (lt) 21

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 112

Fuel Consumption (lt/h)100% 27,4

50% 15,1

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT 150

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %92,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1260x3350x1920 1995 240

OPEN SET 1094x3200x1600 1535 240

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G145 DIESEL GENERATOR SET / 50Hz

109

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power165 kVA

132 KW

Prime Power150 kVA

120 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TAD731GE

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 7,15

Bore / Stroke (mm) 108 / 130

Cycle 4

Compression Ratio 18:1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 23,8

Lubrication Oil Capacity (lt) 21

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 133

Fuel Consumption (lt/h)100% 33,8

50% 18,8

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-165

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1260x3350x1910 2950 340

OPEN SET 1110x3200x1920 2150 340

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G165 DIESEL GENERATOR SET / 50Hz

110

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power200 kVA

160 KW

Prime Power180 kVA

144 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TAD732GE EDC4

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 7,15

Bore / Stroke (mm) 108 / 130

Cycle 4

Compression Ratio 18: 1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 38,4

Lubrication Oil Capacity (lt) 34

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 160

Fuel Consumption (lt/h)100% 40,3

50% 22,1

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT 200

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1110x3950x2170 3150 340

OPEN SET 1094x2570x1765 2400 340

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G200 DIESEL GENERATOR SET / 50Hz

111

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power220 kVA

176 KW

Prime Power200 kVA

160 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TAD733GE EDC4

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 7,15

Bore / Stroke (mm) 108 / 130

Cycle 4

Compression Ratio 18.1: 1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 38,4

Lubrication Oil Capacity (lt) 34

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 175

Fuel Consumption (lt/h)100% 45,3

50% 24,9

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT 220

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1110x3950x2170 3330 400

OPEN SET 1094x2570x1765 2550 400

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G220 DIESEL GENERATOR SET / 50Hz

112

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power275 kVA

220 KW

Prime Power250 kVA

200 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TAD734GE

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 7,15

Bore / Stroke (mm) 108 / 130

Cycle 4

Compression Ratio 17: 1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 42

Lubrication Oil Capacity (lt) 29

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 213

Fuel Consumption (lt/h)100% 51

50% 29

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT275

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1110x3950x2170 3450 400

OPEN SET 1094x2570x1765 2700 400

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G275 DIESEL GENERATOR SET / 50Hz

113

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power330 kVA

264 KW

Prime Power300 kVA

240 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TAD1341GE

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 12,78

Bore / Stroke (mm) 131 / 158

Cycle 4

Compression Ratio 18.1: 1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 44

Lubrication Oil Capacity (lt) 36

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 271

Fuel Consumption (lt/h)100% 62,2

50% 33,7

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT 330

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1285x4450x2120 3595 500

OPEN SET 1260x3200x1920 2920 500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G330 DIESEL GENERATOR SET / 50Hz

114

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power385 kVA

308 KW

Prime Power350 kVA

280 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TAD1342GE

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 12,78

Bore / Stroke (mm) 131 / 158

Cycle 4

Compression Ratio 18.1: 1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 44

Lubrication Oil Capacity (lt) 36

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 303

Fuel Consumption (lt/h)100% 68,5

50% 35,1

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-400

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1285x4450x2120 3720 800

OPEN SET 1260x3200x1920 3010 800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G385 DIESEL GENERATOR SET / 50Hz

115

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power414 kVA

331 KW

Prime Power378 kVA

302 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TAD1343GE

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 12,78

Bore / Stroke (mm) 131 / 158

Cycle 4

Compression Ratio 18.1: 1

Aspiration Turbocharged

Governor Type Electromecanic

Cooling System Water

Coolant Capacity (lt) 44

Lubrication Oil Capacity (lt) 36

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 325

Fuel Consumption (lt/h)100% 80,1

50% 43,4

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT 430

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1285x4450x2120 3625 800

OPEN SET 1260x3200x1920 2915 800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G414 DIESEL GENERATOR SET / 50Hz

116

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power440 kVA

352 KW

Prime Power400 kVA

320 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TAD1344GE

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 12,78

Bore / Stroke (mm) 131 / 158

Cycle 4

Compression Ratio 18.1: 1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 44

Lubrication Oil Capacity (lt) 36

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 354

Fuel Consumption (lt/h)100% 81,3

50% 44,1

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT 450

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1285x4450x2120 3825 800

OPEN SET 1260x3200x192 3115 800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G440 DIESEL GENERATOR SET / 50Hz

117

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power500 kVA

400 KW

Prime Power455 kVA

364 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TAD1345GE

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 12,78

Bore / Stroke (mm) 131 / 158

Cycle 4

Compression Ratio 18.1: 1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 60

Lubrication Oil Capacity (lt) 48

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 388

Fuel Consumption (lt/h)100% 91,8

50% 49,8

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT 500

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %95

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1400x4810x2390 4640 800

OPEN SET 1370x3500x2180 3640 800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G500 DIESEL GENERATOR SET / 50Hz

118

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power550 kVA

440 KW

Prime Power500 kVA

400 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TAD1641GE

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 16,12

Bore / Stroke (mm) 144 / 165

Cycle 4

Compression Ratio 16.5: 1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 60

Lubrication Oil Capacity (lt) 48

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 430

Fuel Consumption (lt/h)100% 101,3

50% 55,0

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT 550

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %95

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1400x4810x2390 4645 1000

OPEN SET 1370x3500x2180 3685 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G550 DIESEL GENERATOR SET / 50Hz

119

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power650 kVA

520 KW

Prime Power590 kVA

472 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TWD1642GE

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 16,12

Bore / Stroke (mm) 144 / 165

Cycle 4

Compression Ratio 16.5: 1

Aspiration Turbo Aftercooler

Governor Type Electromecanic

Cooling System Water

Coolant Capacity (lt) 95

Lubrication Oil Capacity (lt) 48

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 503

Fuel Consumption (lt/h)100% 116,3

50% 63,2

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT 660

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1700x4820x2600 5326 1500

OPEN SET 1670x3500x2235 4219 1500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G650 DIESEL GENERATOR SET / 50Hz

120

www.grandvoltage.roVOLVO – GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power700 kVA

556 KW

Prime Power630 kVA

504 KW

ENGINE (ESP -STAND-BY)

Manufacturer VOLVO

Origin SWEDEN

Model TWD1643GE

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 16,12

Bore / Stroke (mm) 144 / 165

Cycle 4

Compression Ratio 16.5: 1

Aspiration Turbo Aftercooler

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 95

Lubrication Oil Capacity (lt) 48

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 536

Fuel Consumption (lt/h)100% 126,2

50% 68,6

ALTERNATOR

Manufacturer GENTECH

Origin TR

Model GNT 700

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %95,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1700x4820x2600 5516 1500

OPEN SET 1670x3500x2235 4439 1500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVV-G700 DIESEL GENERATOR SET / 50Hz

121

Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code

OpenOrder Code

CanopiedSTAND-BY POWER

PRIME POWER

OPEN CANOPIED OPEN CANOPIED

GVD40 40 kVA 36 kVA 1000x2400x1385 1000x2900x1710 825 1105 GV31465025 GV31465047

GVD52 52 kVA 47 kVA 1000x2400x1385 1000x2900x1710 920 1195 GV31465026 GV31465048

GVD60 60 kVA 55 kVA 1000x2400x1385 1000x2900x1710 920 1195 GV31465027 GV31465049

GVD70 70 kVA 64 kVA 1000x2400x1480 1000x2900x1710 1060 1340 GV31465028 GV31465050

GVD110 110 kVA 100 kVA 1000x2400x1480 1000x2900x1710 1410 1130 GV31465030 GV31465052

GVD130 130 kVA 120 kVA 1050x3100x1700 1050x3580x2025 1400 1770 GV31465031 GV31465053

GVD150 150 kVA 136 kVA 1050x3100x1700 1050x3580x2025 1400 1770 GV31465032 GV31465054

GVD167 167 kVA 152 kVA 1050x3100x1700 1050x3580x2025 1610 1980 GV31465033 GV31465055

GVD180 180 kVA 164 kVA 1050x3100x1700 1050x3580x2025 1610 1980 GV31465034 GV31465056

GVD200 200 kVA 182 kVA 1050x2500x1710 1050x3580x2025 1620 1890 GV31465035 GV31465057

GVD215 215 kVA 196 kVA 1050x2500x1710 1090x3380x2000 1620 1890 GV31465036 GV31465058

GVD235 235 kVA 214 kVA 1050x3100x1700 1050x3580x2025 1790 2160 GV31465037 GV31465059

GVD290 290 kVA 263 kVA 1400x3000x2226 1400x3300x2550 2440 2940 GV31465038 GV31465060

GVD360 360 kVA 325 kVA 1600x3000x2650 1600x3600x2090 2600 3050 GV31465039 GV31465061

GVD400 400 kVA 357 kVA 1600x3000x2650 1600x3600x2550 2700 3340 GV31465040 GV31465062

GVD460 460 kVA 414 kVA 1600x3000x2650 1600x3600x2550 2750 3460 GV31465041 GV31465063

GVD550 550 kVA 500 kVA 1600x3500x2680 1600x4000x2660 3285 3980 GV31465042 GV31465064

GVD615 615 kVA 555 kVA 1600x3500x2680 1600x4000x2665 3420 4080 GV31465043 GV31465065

GVD640 640 kVA 580 kVA 1600x3500x2680 1600x4000x2665 3490 4150 GV31465044 GV31465066

GVD675 675 kVA 614 kVA 1600x3500x2680 1600x4000x2665 3540 4200 GV31465045 GV31465067

GVD700 700 kVA 363 kVA 1600x3500x2680 1600x4000x2665 3540 4250 GV31465046 GV31465068

122

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power40 kVA

32 KW

Prime Power36 kVA

28,8 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model D226B-3D

No of Cylinder / Configuration 3 / IN LINE

Displacement (lt) 3,117

Bore / Stroke (mm) 105 / 120

Cycle 4

Compression Ratio 16.40 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 12

Lubrication Oil Capacity (lt) 7,25

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 36,5

Fuel Consumption (lt/h)100% 8,12

50% 4,06

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-40

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %85,4

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1000x2900x1710 1105 170

OPEN SET 1000x2400x1385 825 170

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD40 DIESEL GENERATOR SET / 50Hz

123

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power52 kVA

41,6 KW

Prime Power47,3 kVA

37,8 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model TD226B-3D

No of Cylinder / Configuration 3 / IN LINE

Displacement (lt) 3,117

Bore / Stroke (mm) 105 / 120

Cycle 4

Compression Ratio 15.50 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 12

Lubrication Oil Capacity (lt) 7,25

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 55,2

Fuel Consumption (lt/h)100% 11,77

50% 5,89

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-55

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %87,2

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1000x2900x1710 1195 170

OPEN SET 1000x2400x1385 920 170

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD52 DIESEL GENERATOR SET / 50Hz

124

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power60 kVA

48 KW

Prime Power54,5 kVA

43,6 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model TD226B-3D

No of Cylinder / Configuration 3 / IN LINE

Displacement (lt) 3,117

Bore / Stroke (mm) 105 / 120

Cycle 4

Compression Ratio 15.50 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 17,2

Lubrication Oil Capacity (lt) 7,25

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 55,2

Fuel Consumption (lt/h)100% 13,58

50% 6,79

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-66

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %87,2

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1000x2900x1710 1195 170

OPEN SET 1000x2400x1385 920 170

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD60 DIESEL GENERATOR SET / 50Hz

125

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power70 kVA

56 KW

Prime Power63,6 kVA

50,9 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model WP4D66E200-E

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,5

Bore / Stroke (mm) 105 / 130

Cycle 4

Compression Ratio 18:1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 15,3

Lubrication Oil Capacity (lt) 10

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 66

Fuel Consumption (lt/h)100% 13,84

50% 7,50

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-75

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %88

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1000x2900x1710 1340 170

OPEN SET 1000x2400x1480 1060 170

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD70 DIESEL GENERATOR SET / 50Hz

126

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power110 kVA

88 KW

Prime Power100 kVA

80 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model WP4D66E200-D

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,5

Bore / Stroke (mm) 105 / 130

Cycle 4

Compression Ratio 18:1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 15,3

Lubrication Oil Capacity (lt) 10

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 99

Fuel Consumption (lt/h)100% 20,76

50% 11,26

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-110

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %90

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1000x2900x1710 1410 170

OPEN SET 1000x2400x1480 1130 170

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD110 DIESEL GENERATOR SET / 50Hz

127

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power130 kVA

104 KW

Prime Power120 kVA

96 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model WP4D100E200-D

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,5

Bore / Stroke (mm) 105 / 130

Cycle 4

Compression Ratio 18 :1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 16,3

Lubrication Oil Capacity (lt) 10

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 132

Fuel Consumption (lt/h)100% 25,01

50% 12,97

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-135

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1050x3580x2025 1770 350

OPEN SET 1050x3100x1700 1400 350

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD130 DIESEL GENERATOR SET / 50Hz

128

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power150 kVA

120 KW

Prime Power136 kVA

108,8 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model WP4D100E200-D

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,5

Bore / Stroke (mm) 105 / 130

Cycle 4

Compression Ratio 18 :1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 16,3

Lubrication Oil Capacity (lt) 10

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 132

Fuel Consumption (lt/h)100% 28,05

50% 14,54

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-150

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %92,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1050x3580x2025 1770 350

OPEN SET 1050x3100x1700 1400 350

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD150 DIESEL GENERATOR SET / 50Hz

129

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power167 kVA

133,6 KW

Prime Power152 kVA

121,6 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model WP6D132E200-E

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,75

Bore / Stroke (mm) 105 / 130

Cycle 4

Compression Ratio 18 :1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 26

Lubrication Oil Capacity (lt) 20

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 146

Fuel Consumption (lt/h)100% 30,5

50% 15,48

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-175

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1050x3580x2025 1980 350

OPEN SET 1050x3100x1700 1610 350

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD167 DIESEL GENERATOR SET / 50Hz

130

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power180 kVA

144 KW

Prime Power164 kVA

131,2 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model WP6D132E200-D

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,75

Bore / Stroke (mm) 105 / 130

Cycle 4

Compression Ratio 18 :1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 26

Lubrication Oil Capacity (lt) 20

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 175

Fuel Consumption (lt/h)100% 32,79

50% 16,79

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-194

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1050x3580x2025 1980 350

OPEN SET 1050x3100x1700 1610 350

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD180 DIESEL GENERATOR SET / 50Hz

131

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power200 kVA

160 KW

Prime Power182 kVA

145,6 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model WP6D132E200-D

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,75

Bore / Stroke (mm) 105 / 130

Cycle 4

Compression Ratio 18 :1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 26

Lubrication Oil Capacity (lt) 20

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 175

Fuel Consumption (lt/h)100% 36,44

50% 18,65

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-200

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,1

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1050x3580x2025 2005 350

OPEN SET 1050x3100x1700 1635 350

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD200 DIESEL GENERATOR SET / 50Hz

132

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power215 kVA

172 KW

Prime Power196 kVA

156,8 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model WP6D152E200-E

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,75

Bore / Stroke (mm) 105 / 130

Cycle 4

Compression Ratio 18 :1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 17

Lubrication Oil Capacity (lt) 9

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 186

Fuel Consumption (lt/h)100% 39,03

50% 20,31

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-220

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,2

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1090x3380x2000 1890 350

OPEN SET 1050x2500x1710 1620 350

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD215 DIESEL GENERATOR SET / 50Hz

133

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power235 kVA

188 KW

Prime Power214 kVA

171,2 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model WP6D152E200-D

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,75

Bore / Stroke (mm) 105 / 130

Cycle 4

Compression Ratio 18 :1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 26

Lubrication Oil Capacity (lt) 20

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 203

Fuel Consumption (lt/h)100% 42,71

50% 22,22

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-250

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,2

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1050x3580x2025 2160 350

OPEN SET 1050x3100x1700 1790 350

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD235 DIESEL GENERATOR SET / 50Hz

134

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power290 kVA

232 KW

Prime Power263 kVA

210 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model BF6M1015-LA-GA

No of Cylinder / Configuration 6 / V TYPE

Displacement (lt) 11,906

Bore / Stroke (mm) 132 / 145

Cycle 4

Compression Ratio 16.5: 1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 62

Lubrication Oil Capacity (lt) 36

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 231

Fuel Consumption (lt/h)100% 52,31

50% 26,78

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-330

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,2

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1400x3300x2550 2940 700

OPEN SET 1400x3000x2226 2440 700

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD290 DIESEL GENERATOR SET / 50Hz

135

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power360 kVA

288 KW

Prime Power325 kVA

260 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model BF6M1015C-LA-G2A

No of Cylinder / Configuration 6 / V TYPE

Displacement (lt) 11,906

Bore / Stroke (mm) 132 / 145

Cycle 4

Compression Ratio 16.50 :1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 62

Lubrication Oil Capacity (lt) 36

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 285

Fuel Consumption (lt/h)100% 63,92

50% 32,74

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-360

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1600x3600x2550 3215 700

OPEN SET 1600x3000x2650 2665 700

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD360 DIESEL GENERATOR SET / 50Hz

136

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power400 kVA

320 KW

Prime Power357 kVA

285 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model BF6M1015C-LA-G3A

No of Cylinder / Configuration 6 / V TYPE

Displacement (lt) 11,906

Bore / Stroke (mm) 132 / 145

Cycle 4

Compression Ratio 16.5:1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 62

Lubrication Oil Capacity (lt) 36

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 314

Fuel Consumption (lt/h)100% 70,08

50% 34,70

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-400

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1600x3600x2550 3340 700

OPEN SET 1600x3000x2650 2700 700

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD400 DIESEL GENERATOR SET / 50Hz

137

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power460 kVA

368 KW

Prime Power415 kVA

332 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model BF6M1015CP-LA-G

No of Cylinder / Configuration 6 / V TYPE

Displacement (lt) 11,906

Bore / Stroke (mm) 132 / 145

Cycle 4

Compression Ratio 16.5:1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 67

Lubrication Oil Capacity (lt) 36

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 365

Fuel Consumption (lt/h)100% 83,85

50% 41,33

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-500

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,3

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1600x3600x2550 3460 700

OPEN SET 1600x3000x2650 2750 700

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD460 DIESEL GENERATOR SET / 50Hz

138

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power550 kVA

440 KW

Prime Power500 kVA

400 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model BF8M1015C-LA-G2

No of Cylinder / Configuration 8 / V TYPE

Displacement (lt) 15,874

Bore / Stroke (mm) 132 / 145

Cycle 4

Compression Ratio 16.5 :1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 87

Lubrication Oil Capacity (lt) 48

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 440

Fuel Consumption (lt/h)100% 98,68

50% 48,86

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-550

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,4

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1600x4000x2660 3980 1000

OPEN SET 1600x3500x2680 3285 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD550 DIESEL GENERATOR SET / 50Hz

139

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power615 kVA

492 KW

Prime Power555 kVA

444 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model BF8M1015CP-LA-G2

No of Cylinder / Configuration 8 / V TYPE

Displacement (lt) 15,874

Bore / Stroke (mm) 132 / 145

Cycle 4

Compression Ratio 16.5:1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 93

Lubrication Oil Capacity (lt) 48

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 490

Fuel Consumption (lt/h)100% 117,37

50% 55,75

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-615

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,4

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1600x4000x2665 4080 1000

OPEN SET 1600x3500x2680 3420 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD615 DIESEL GENERATOR SET / 50Hz

140

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power640 kVA

512 KW

Prime Power580 kVA

464 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model BF8M1015CP-LA-G3

No of Cylinder / Configuration 8 / V TYPE

Displacement (lt) 15,874

Bore / Stroke (mm) 132 / 145

Cycle 4

Compression Ratio 16.50 :1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 93

Lubrication Oil Capacity (lt) 48

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 509

Fuel Consumption (lt/h)100% 125,24

50% 56,80

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-660

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1600x4000x2665 4150 1000

OPEN SET 1600x3500x2680 3490 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD640 DIESEL GENERATOR SET / 50Hz

141

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power675 kVA

540 KW

Prime Power614 kVA

491 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model BF8M1015CP-LA-G4

No of Cylinder / Configuration 8 / V TYPE

Displacement (lt) 15,874

Bore / Stroke (mm) 132 / 145

Cycle 4

Compression Ratio 16.50 :1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 93

Lubrication Oil Capacity (lt) 48

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 540

Fuel Consumption (lt/h) 100% 132,87

50% 60,26

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-675

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,5

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1600x4000x2665 4200 1000

OPEN SET 1600x3500x2680 3540 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD675 DIESEL GENERATOR SET / 50Hz

142

www.grandvoltage.roDEUTZ - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power700 kVA

560 KW

Prime Power636 kVA

509 KW

ENGINE (ESP -STAND-BY)

Manufacturer DEUTZ

Origin CHINA

Model BF8M1015CP-LA-G5

No of Cylinder / Configuration 8 / V TYPE

Displacement (lt) 15,874

Bore / Stroke (mm) 132 / 145

Cycle 4

Compression Ratio 16.50 :1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 93

Lubrication Oil Capacity (lt) 48

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 560

Fuel Consumption (lt/h) 100% 137,79

%50 62,49

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-700

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94,4

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1600x4000x2665 4250 1000

OPEN SET 1600x3500x2680 3540 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVD700 DIESEL GENERATOR SET / 50Hz

143

Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code

CanopiedSTAND-BY POWER

PRIME POWER

OPEN CANOPIED OPEN CANOPIED

GVR-C21 21 kVA 19,1 kVA - 950x2050x1100 - 750 GV31465079

GVR-C42 42 kVA 37,1 kVA - 950x2050x1200 - 950 GV31465081

GVR-C55 55 kVA 47,2 kVA - 950x2050x1200 - 1200 GV31465082

GVR-C70 70 kVA 63 kVA - 950x2050x1300 - 1250 GV31465083

GVR-C105 105 kVA 95 kVA - 1050x2900x1750 - 1350 GV31465084

GVR-C125 125 kVA 112 kVA - 1050x2900x1750 - 1650 GV31465085

GVR-C140 140 kVA 127 kVA - 1050x2900x1750 - 1800 GV31465086

GVR-C150 150 kVA 135 kVA - 1050x2900x1750 - 1800 GV31465087

GVR-C165 165 kVA 148,5 kVA - 1050x2900x1750 - 1900 GV31465088

GVR-C220 220 kVA 200 kVA - 1200x3250x1950 - 2000 GV31465090

GVR-C258 258 kVA 232 kVA - 1200x3400x2000 - 2500 GV31465091

GVR-C325 325 kVA 292 kVA - 1350x3800x2200 - 2600 GV31465093

144

www.grandvoltage.roRICARDO C - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power21 kVA

17 KW

Prime Power19,1 kVA

15,2 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model 4100DS

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 3,61

Bore / Stroke (mm) 95 / 115

Cycle 4

Compression Ratio 19 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 7

Lubrication Oil Capacity (lt) 15

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 26,5

Fuel Consumption (lt/h)100% 8,1

50% 4,6

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-25

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 950x2050x1100 750 61

OPEN SET - - -

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-C21 DIESEL GENERATOR SET / 50Hz

145

www.grandvoltage.roRICARDO C - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power42 kVA

33 KW

Prime Power37,1 kVA

29,7 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model 4102DS

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 3,61

Bore / Stroke (mm) 102 / 115

Cycle 4

Compression Ratio 16 :1

Aspiration Natural

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 7

Lubrication Oil Capacity (lt) 15

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 33

Fuel Consumption (lt/h)100% 9,3

50% 5,4

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-45

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 950x2050x1200 950 61

OPEN SET - - -

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-C42 DIESEL GENERATOR SET / 50Hz

146

www.grandvoltage.roRICARDO C - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power53 kVA

43 KW

Prime Power47,2 kVA

38 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model 4102ZDS

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 3,61

Bore / Stroke (mm) 102 / 115

Cycle 4

Compression Ratio 16 :1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 9

Lubrication Oil Capacity (lt) 15

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 42

Fuel Consumption (lt/h)100% 11,8

50% 6,4

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-55

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 950x2050x1200 1200 69

OPEN SET - - -

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-C53 DIESEL GENERATOR SET / 50Hz

147

www.grandvoltage.roRICARDO C - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power70 kVA

56 KW

Prime Power63 kVA

50 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model 4105ZDS

No of Cylinder / Configuration 4 / IN LINE

Displacement (lt) 4,32

Bore / Stroke (mm) 105 / 120

Cycle 4

Compression Ratio 16 :1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 9

Lubrication Oil Capacity (lt) 15

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 56

Fuel Consumption (lt/h)100% 15,7

50% 8,7

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-70

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 950x2050x1300 1250 69

OPEN SET - - -

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-C70 DIESEL GENERATOR SET / 50Hz

148

www.grandvoltage.roRICARDO C - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power105 kVA

84 KW

Prime Power95 kVA

76 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model 6105ZDS1

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 4,32

Bore / Stroke (mm) 105 / 125

Cycle 4

Compression Ratio 17 :1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 11

Lubrication Oil Capacity (lt) 26

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 84

Fuel Consumption (lt/h)100% 23,6

50% 12,9

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-105

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1050x2900x1750 1350 168

OPEN SET - - -

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-C105 DIESEL GENERATOR SET / 50Hz

149

www.grandvoltage.roRICARDO C - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power125 kVA

100 KW

Prime Power112 kVA

89 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model 6105ZLDS1

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 4,32

Bore / Stroke (mm) 105 / 125

Cycle 4

Compression Ratio 17 :1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 11

Lubrication Oil Capacity (lt) 26

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 100

Fuel Consumption (lt/h)100% 28,1

50% 15,3

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-125

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1050x2900x1750 1650 168

OPEN SET - - -

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-C125 DIESEL GENERATOR SET / 50Hz

150

www.grandvoltage.roRICARDO C - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power140 kVA

112 KW

Prime Power127 kVA

102 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model 6105ZLDS1

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,49

Bore / Stroke (mm) 105 / 125

Cycle 4

Compression Ratio 17 :1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 11

Lubrication Oil Capacity (lt) 26

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 110

Fuel Consumption (lt/h)100% 30,9

50% 16,7

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-140

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1050x2900x1750 1800 150

OPEN SET - - -

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-C140 DIESEL GENERATOR SET / 50Hz

151

www.grandvoltage.roRICARDO C - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power150 kVA

120 KW

Prime Power135 kVA

108 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model 6105AZLDS1

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,49

Bore / Stroke (mm) 105 / 125

Cycle 4

Compression Ratio 17 :1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 11

Lubrication Oil Capacity (lt) 26

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 120

Fuel Consumption (lt/h)100% 33,7

50% 18,4

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-150

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1050x2900x1750 1800 150

OPEN SET - - -

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-C150 DIESEL GENERATOR SET / 50Hz

152

www.grandvoltage.roRICARDO C - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power165 kVA

132 KW

Prime Power148,5 kVA

119 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model 6105BZLDS

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,49

Bore / Stroke (mm) 105 / 125

Cycle 4

Compression Ratio 17 :1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 11

Lubrication Oil Capacity (lt) 26

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 132

Fuel Consumption (lt/h)100% 37,1

50% 20,2

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-165

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1050x2900x1750 1900 150

OPEN SET - - -

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-C165 DIESEL GENERATOR SET / 50Hz

153

www.grandvoltage.roRICARDO C - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power220 kVA

176 KW

Prime Power200 kVA

160 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model 6110ZLDS

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,49

Bore / Stroke (mm) 105 / 125

Cycle 4

Compression Ratio 17 :1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 11

Lubrication Oil Capacity (lt) 26

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 132

Fuel Consumption (lt/h)100% 49,8

50% 27,1

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-220

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1050x2900x1750 2000 230

OPEN SET - - -

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-C220 DIESEL GENERATOR SET / 50Hz

154

www.grandvoltage.roRICARDO C - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power258 kVA

206 KW

Prime Power232 kVA

185,5 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model 6135AZLD-1

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 6,49

Bore / Stroke (mm) 126 / 130

Cycle 4

Compression Ratio 17 :1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 39

Lubrication Oil Capacity (lt) 40

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 231

Fuel Consumption (lt/h)100% 65

50% 35,2

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-260

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1200x3400x1900 2500 260

OPEN SET - - -

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-C258 DIESEL GENERATOR SET / 50Hz

155

www.grandvoltage.roRICARDO C - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power325 kVA

284 KW

Prime Power295 kVA

258 KW

ENGINE (ESP -STAND-BY)

Manufacturer RICARDO

Origin CHINA

Model 6135BZLD

No of Cylinder / Configuration 6 / IN LINE

Displacement (lt) 13,31

Bore / Stroke (mm) 135 / 150

Cycle 4

Compression Ratio 14,8 :1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 50

Lubrication Oil Capacity (lt) 19

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 231

Fuel Consumption (lt/h)100% 66,72

50% 33,3

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-325

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %1

Insulation Class H

Degree of Protection IP 22/23

Excitation System AVR, Brushless

Connection Type Y Type

Total Harmonic Content (No Load) < %3

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1350x3800x2200 3380 260

OPEN SET - - -

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVR-C325 DIESEL GENERATOR SET / 50Hz

156

Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code

OpenOrder Code

CanopiedSTAND-BY POWER

PRIME POWER

OPEN CANOPIED OPEN CANOPIED

GVX250 250 227 1500x2800x1720 1500x2800x2580 2113 3100 GV314622790 GV314622807

GVX300 300 273 1500x3100x1960 1500x4200x2580 2900 4004 GV314622791 GV314622808

GVX350 350 318 1500x2800x1720 1500x2800x2580 3004 4004 GV314622792 GV314622809

GVX385 385 350 1500x2800x1720 1500x2800x2580 3004 4404 GV314622793 GV314622810

GVX425 425 386 1500x3100x1900 1500x4200x2580 3441 4406 GV314622794 GV314622811

GVX480 480 436 1500x3100x1900 1500x4200x2580 3526 4426 GV314622795 GV314622812

GVX550 550 500 1500x3500x2170 1500x4600x2810 4070 5094 GV314622796 GV314622813

GVX580 580 527 1800x4000x2100 2200x4700x2400 4800 5500 GV314622797 GV314622814

GVX630 630 573 1500x3500x2200 1500x4600x2810 4188 5095 GV314622798 GV314622815

GVX700 700 636 2100x3350x2200 2440x6600x2590 5072 7452 GV314622799 GV314622816

GVX830 830 755 2100x3350x2200 2440x6060x2590 6604 8414 GV314622800 GV314622817

GVX900 900 818 2100x3900x2200 2430x6050x2590 7264 9014 GV314622801 GV314622818

GVX950 950 864 2100x4650x2550 2430x6050x2590 9303 11053 GV314622802 GV314622819

GVX1020 1020 927 2100x4650x2550 2430x6050x2600 9303 11053 GV314622803 GV314622820

GVX1100 1100 1000 2100x4650x2550 2430x6050x2590 9608 11358 GV314622804 GV314622821

GVX1250 1250 1136 2100x4650x2550 2430x6050x2600 9608 11358 GV314622805 GV314622822

GVX1375 1375 1250 1900x4650x2550 2430x6050x2890 9722 15220 GV314622806 GV314622823

157

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power250 kVA

200 KW

Prime Power227 kVA

182 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model X6135AZLD-1

No of Cylinder / Configuration 6

Displacement (lt) 12,9

Bore / Stroke (mm) 135 / 150

Cycle 4

Compression Ratio 16.00: 1

Aspiration Turbocharged

Governor Type Mechanical

Cooling System Water

Coolant Capacity (lt) 44

Lubrication Oil Capacity (lt) 28,7

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 227

Fuel Consumption (lt/h)%100 44,45

%50 26,67

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-250

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x2800x2580 3100 400

OPEN SET 1500x2800x1720 2113 400

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX 250 DIESEL GENERATOR SET / 50Hz

158

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power300 kVA

240 KW

Prime Power273 kVA

218 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model X6135BZLD

No of Cylinder / Configuration 6

Displacement (lt) 12,9

Bore / Stroke (mm) 135 / 150

Cycle 4

Compression Ratio 16.00: 1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 70

Lubrication Oil Capacity (lt) 34,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 263

Fuel Consumption (lt/h)%100 53,34

%50 32,01

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-330

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4200x2580 4004 500

OPEN SET 1500x3100x1960 2900 500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX300 DIESEL GENERATOR SET / 50Hz

159

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power350 kVA

280 KW

Prime Power318 kVA

255 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model XG128ZLD11

No of Cylinder / Configuration 6

Displacement (lt) 12,9

Bore / Stroke (mm) 135 / 150

Cycle 4

Compression Ratio 16.00: 1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 70

Lubrication Oil Capacity (lt) 34,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 308

Fuel Consumption (lt/h)%100 62,23

%50 37,34

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-350

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x2800x2580 4004 500

OPEN SET 1500x2800x1720 3004 500

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX350 DIESEL GENERATOR SET / 50Hz

160

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power385 kVA

308 KW

Prime Power350 kVA

280 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model XG128ZLD5

No of Cylinder / Configuration 6

Displacement (lt) 12,9

Bore / Stroke (mm) 135 / 150

Cycle 4

Compression Ratio 16.00: 1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 70

Lubrication Oil Capacity (lt) 34,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 340

Fuel Consumption (lt/h)%100 62,23

%50 37,34

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-400

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %94

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x2800x2580 4404 800

OPEN SET 1500x2800x1720 3004 800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX385 DIESEL GENERATOR SET / 50Hz

161

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power425 kVA

340 KW

Prime Power386 kVA

309 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model XG128ZLD3

No of Cylinder / Configuration 6 / V TYPE

Displacement (lt) 12,9

Bore / Stroke (mm) 135 / 160

Cycle 4

Compression Ratio 16.00: 1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 70

Lubrication Oil Capacity (lt) 34,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 375

Fuel Consumption (lt/h)%100 76,06

%50 45,64

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-430

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4200x2580 4406 800

OPEN SET 1500x3100x1900 3441 800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX425 DIESEL GENERATOR SET / 50Hz

162

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power480 kVA

384 KW

Prime Power436 kVA

349 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model XG128ZLD4

No of Cylinder / Configuration 6

Displacement (lt) 12,9

Bore / Stroke (mm) 135 / 168

Cycle 4

Compression Ratio 16.00: 1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 70

Lubrication Oil Capacity (lt) 34,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 420

Fuel Consumption (lt/h)%100 85,94

%50 51,57

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-500

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4200x2580 4426 800

OPEN SET 1500x3100x1900 3526 800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX480 DIESEL GENERATOR SET / 50Hz

163

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power550 kVA

440 KW

Prime Power500 kVA

400 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model XG128ZLD6

No of Cylinder / Configuration 6

Displacement (lt) 12,9

Bore / Stroke (mm) 135 / 168

Cycle 4

Compression Ratio 16.00: 1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 70

Lubrication Oil Capacity (lt) 34,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 460

Fuel Consumption (lt/h)%100 98,78

%50 59,27

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-550

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4600x2810 5094 800

OPEN SET 1500x3500x2170 4070 800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX550 DIESEL GENERATOR SET / 50Hz

164

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power580 kVA

464 KW

Prime Power527 kVA

422 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model X12V135BZLD-1

No of Cylinder / Configuration 12

Displacement (lt) 26,6

Bore / Stroke (mm) 135 / 155

Cycle 4

Compression Ratio 16.00: 1

Aspiration Turbocharged

Governor Type Electronic

Cooling System Water

Coolant Capacity (lt) 84

Lubrication Oil Capacity (lt) 57,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 510

Fuel Consumption (lt/h)%100 103,72

%50 62,23

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-600

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2200x4700x2400 5500 800

OPEN SET 1800x4000x2100 4800 800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX580 DIESEL GENERATOR SET / 50Hz

165

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power630 kVA

504 KW

Prime Power573 kVA

458 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model X12V135BZLD-2

No of Cylinder / Configuration 12 / V TYPE

Displacement (lt) 26,6

Bore / Stroke (mm) 135 / 155

Cycle 4

Compression Ratio 16.00: 1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 84

Lubrication Oil Capacity (lt) 57,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 550

Fuel Consumption (lt/h)%100 113,6

%50 68,16

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-630

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 1500x4600x2810 5095 1000

OPEN SET 1500x3500x2200 4188 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX630 DIESEL GENERATOR SET / 50Hz

166

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power700 kVA

560 KW

Prime Power636 kVA

509 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model X12V135CZLD

No of Cylinder / Configuration 12

Displacement (lt) 26,6

Bore / Stroke (mm) 135 / 155

Cycle 4

Compression Ratio 16.00: 1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 84

Lubrication Oil Capacity (lt) 57,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 610

Fuel Consumption (lt/h)%100 124,46

%50 74,68

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-700

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2440x6600x2590 7452 1000

OPEN SET 2100x3350x2200 5072 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX700 DIESEL GENERATOR SET / 50Hz

167

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power830 kVA

664 KW

Prime Power755 kVA

604 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model X12V135CZLD-2

No of Cylinder / Configuration 12

Displacement (lt) 27

Bore / Stroke (mm) 135 / 160

Cycle 4

Compression Ratio 16.00: 1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 84

Lubrication Oil Capacity (lt) 57,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 720

Fuel Consumption (lt/h)100% 148

50% 88,90

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-850

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2440x6060x2590 6850 1000

OPEN SET 2100x3350x2200 4890 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX830 DIESEL GENERATOR SET / 50Hz

168

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power900 kVA

720 KW

Prime Power818 kVA

655 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model X12V138ZLD

No of Cylinder / Configuration 12

Displacement (lt) 28,9

Bore / Stroke (mm) 138 / 165

Cycle 4

Compression Ratio 16.00: 1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 84

Lubrication Oil Capacity (lt) 58,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 780

Fuel Consumption (lt/h)100% 161,01

50% 96,61

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-950

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2590 9014 1000

OPEN SET 2100x3900x2200 7264 1000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX900 DIESEL GENERATOR SET / 50Hz

169

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power950 kVA

760 KW

Prime Power864 kVA

691 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model X12V138CZLD

No of Cylinder / Configuration 12

Displacement (lt) 31,4

Bore / Stroke (mm) 138 / 168

Cycle 4

Compression Ratio 16.00: 1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 84

Lubrication Oil Capacity (lt) 60,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 820

Fuel Consumption (lt/h)100% 169,90

50% 101,94

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-950

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2590 11053 2000

OPEN SET 2100x4650x2550 9303 2000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX950 DIESEL GENERATOR SET / 50Hz

170

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1020 kVA

816 KW

Prime Power927 kVA

742 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model X12V138CZLD-1

No of Cylinder / Configuration 12

Displacement (lt) 31,4

Bore / Stroke (mm) 138 / 168

Cycle 4

Compression Ratio 17.5: 1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 84

Lubrication Oil Capacity (lt) 60,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 880

Fuel Consumption (lt/h)100% 182,75

50% 109,65

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-1100

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2600 11053 2000

OPEN SET 2100x4650x2550 9303 2000

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX1020 DIESEL GENERATOR SET / 50Hz

171

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1100 kVA

880 KW

Prime Power1000 kVA

800 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model X12V138CZLD-2

No of Cylinder / Configuration 12

Displacement (lt) 31,4

Bore / Stroke (mm) 138 / 168

Cycle 4

Compression Ratio 17.5: 1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 84

Lubrication Oil Capacity (lt) 60,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 960

Fuel Consumption (lt/h)100% 197,56

50% 118,54

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-1100

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2590 11358 2440

OPEN SET 2100x4650x2550 9608 2440

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX1100 DIESEL GENERATOR SET / 50Hz

172

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1250 kVA

1000 KW

Prime Power1136 kVA

909 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model XKD30H1070

No of Cylinder / Configuration 12

Displacement (lt) 31,4

Bore / Stroke (mm) 138 / 168

Cycle 4

Compression Ratio 17.5: 1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 84

Lubrication Oil Capacity (lt) 60,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1070

Fuel Consumption (lt/h)100% 243

50% 146

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-1250

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2600 11358 2600

OPEN SET 2100x4650x2550 9608 2600

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX1250 DIESEL GENERATOR SET / 50Hz

173

www.grandvoltage.roXENIC - GENTECH

OUTPUT RATINGS 50 HZ / 400 V

Standby Power1375 kVA

1100 KW

Prime Power1250 kVA

1000 KW

ENGINE (ESP -STAND-BY)

Manufacturer XENIC

Origin CHINA

Model XKD30H1160

No of Cylinder / Configuration 12

Displacement (lt) 31,4

Bore / Stroke (mm) 138 / 168

Cycle 4

Compression Ratio 17/1

Aspiration Turbocharged

Governor Type Electronical

Cooling System Water

Coolant Capacity (lt) 84

Lubrication Oil Capacity (lt) 60,4

Injection Direct

Speed / Frequency 1500 / 50 Hz

Engine Gross Power (kWm) 1160

Fuel Consumption (lt/h)100% 270,48

50% 162,288

ALTERNATOR

Manufacturer GENTECH

Origin TURKEY

Model GNT-1500

No of Phase 3

Power Factor cos 0,8

Number of Bearing SINGLE

No of Poles 4

No of Leads 12

VoltageRegulation (SteadyState) ± %0,5

Insulation Class H

Degree of Protection IP 21/23

Excitation System AVR, Brushless

Connection Type STAR

Total Harmonic Content (No Load) < %2

Frequency (Hz) 50

Voltage Output (VAC) 230 / 400

Efficiency ( %) %93,9

DimensionsWxLxH

mmWeight

kgFuel Tank

ltNoisedb(A)

CANOPIED 2430x6050x2890 15220 2800

OPEN SET 1900x4650x2550 9722 2800

CONTROL UNIT

STANDART: Datakom309 OPTIONAL: Deepsea

Emergency Standby Power (ESP)

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)

Sound Proof Canopy

Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material

GVX1375 DIESEL GENERATOR SET / 50Hz

PortableGenerator Sets

175

Model Phase kVA Start Type Engine HP Order Code

GVB6500E MONO 5,5 Electric Start 13 HP GV31465097

GVB7500E MONO 6,5 Electric Start 16 HP GV31465098

GVB9500E MONO 7,5 Electric Start 17,5 HP GV31465099

GVB9500E-3 THREE 9,5 Electric Start 17,5 HP GV31465100

GVD7000 MONO 7 Electric Start 10 HP GV31465101

GVD7000-3 THREE 7 Electric Start 10 HP GV31465102

GVD7000S MONO 7 Electric Start 10 HP GV31465103

GVD7000S-3 THREE 7 Electric Start 10 HP GV31465104

176

www.grandvoltage.roPORTABLE GENSETS

OUTPUT RATINGS 50 HZ / 220 V

Maximum Power 5,5 kW

Prime Power 5 kW

OUTPUT RATINGS 50 HZ / 220 V

Maximum Power 6.5 kW

Prime Power 6 kW

ENGINE

Manufacturer INTER

Origin CHINA

Model 188FE

Voltage (V) 110/240

Frequency (Hz) 50

Power Factor 1

Protection Class B

Voltage Control AVR

Output Socket 1 pc (DC 12 V)

Dimensions (mm) (LxWxH) 700*530*595

Dry Weight (Kg) 80

Noise Level dba @ 7 mt 74

Engine Type 1 cylinder, 4 P, OHV

Bore x Stroke (mm) 1-90x64

Cylinder Displacement 389

Power (rpm/min) 13 hp / 3000

Compression Rate 8,5:1

Engine Speed 3000

Starting System ELECTRIC STARTER

Fuel Type Petrol

Oil Capacity (L) 1,1

Fuel Tank Capacity (L) 25

Fuel Consumption g/kWh <374

ENGINE

Manufacturer INTER

Origin CHINA

Model 190FE

Voltage (V) 110/240

Frequency (Hz) 50

Power Factor 1

Protection Class B

Voltage Control AVR

Output Socket 1 pc (DC 12 V)

Dimensions (mm) (LxWxH) 700*530*595

Dry Weight (Kg) 83

Noise Level dba @ 7 mt 74

Engine Type 1 cylinder, 4 P, OHV

Bore x Stroke (mm) 1-90x64

Cylinder Displacement 389

Power (rpm/min) 16 hp / 3000

Compression Rate 8,5:1

Engine Speed 3000

Starting System ELECTRIC STARTER

Fuel Type Petrol

Oil Capacity (L) 1,1

Fuel Tank Capacity (L) 25

Fuel Consumption g/kWh <374

GVB6500E GASOLINE GENSET / 50Hz

GVB7500E GASOLINE GENSET / 50Hz

STANDARD FEATURES:STREAM air cooled engineAutomatic engine stop by low oil level1 unit mono phase output socketsStarting BatteriesStrong Baseframe with wheels

STANDARD FEATURES:STREAM air cooled engineAutomatic engine stop by low oil level1 unit mono phase output socketsStarting BatteriesStrong Baseframe with wheels

177

www.grandvoltage.roPORTABLE GENSETS

OUTPUT RATINGS 50 HZ / 220 V

Maximum Power 7,5 kW

Prime Power 7 kW

OUTPUT RATINGS 50 HZ / 220 V

Maximum Power 7,5 kW

Prime Power 7 kW

ENGINE

Manufacturer INTER

Origin CHINA

Model 188FE

Voltage (V) 220

Frequency (Hz) 50

Power Factor 1

Protection Class B

Voltage Control AVR

Output Socket 2 pcs

Dimensions (mm) (LxWxH) 710x540x600

Dry Weight (Kg) 90

Noise Level dba @ 7 mt 79

Engine Type 1 cylinder, 4 P

Bore x Stroke (mm) 92x66

Cylinder Displacement 678

Power (rpm/min) 17,5HP / 3600

Compression Rate 8,5:1

Engine Speed 3000

Starting System ELECTRIC STARTER

Fuel Type Petrol

Oil Capacity (L) 1,5

Fuel Tank Capacity (L) 25

Fuel Consumption g/kWh <374

ENGINE

Manufacturer INTER

Origin CHINA

Model 188FE

Voltage (V) 220

Frequency (Hz) 50

Power Factor 1

Protection Class B

Voltage Control AVR

Output Socket 2 pcs

Dimensions (mm) (LxWxH) 710x540x600

Dry Weight (Kg) 90

Noise Level dba @ 7 mt 79

Engine Type 1 cylinder, 4 P

Bore x Stroke (mm) 92x66

Cylinder Displacement 678

Power (rpm/min) 17,5HP / 3600

Compression Rate 8,5:1

Engine Speed 3000

Starting System ELECTRIC STARTER

Fuel Type Petrol

Oil Capacity (L) 1,5

Fuel Tank Capacity (L) 25

Fuel Consumption g/kWh <374

GVB9500E GASOLINE GENSET / 50Hz

GVB9500E-3 GASOLINE GENSET / 50Hz

STANDARD FEATURES:STREAM air cooled engineAutomatic engine stop by low oil level2 unit mono phase output socketsStarting BatteriesStrong Baseframe with wheels

STANDARD FEATURES:STREAM air cooled engineAutomatic engine stop by low oil level2 unit three phase output socketsStarting BatteriesStrong Baseframe with wheels

178

www.grandvoltage.roPORTABLE GENSETS

OUTPUT RATINGS 50 HZ / 220 V

Maximum Power 7 kW

Prime Power 6,5 kW

OUTPUT RATINGS 50 HZ / 220 V

Maximum Power 7 kW

Prime Power 6,5 kW

ENGINE

Model 188FAE

Voltage (V) 220

Frequency (Hz) 50

Power Factor 1

Protection Class B

Voltage Control AVR

Output Socket 1 pcs (AC)

Dimensions (mm) (LxWxH) 915x547x742

Dry Weight (Kg) 170

Noise Level dba @ 7 mt 72

Engine Type 1 cylinder, 4 P, OHV

Bore x Stroke (mm) 86X70

Cylinder Displacement 418

Power (rpm/min) 10 HP / 3600

Compression Rate 8,5:1

Engine Speed 3000

Starting System ELECTRIC STARTER

Fuel Type Diesel

Oil Capacity (L) 1,7

Fuel Tank Capacity (L) 16

Fuel Consumption g/kWh <280

ENGINE

Model 188FAE

Voltage (V) 220

Frequency (Hz) 50

Power Factor 1

Protection Class B

Voltage Control AVR

Output Socket 1 pcs (AC)

Dimensions (mm) (LxWxH) 915x547x742

Dry Weight (Kg) 170

Noise Level dba @ 7 mt 72

Engine Type 1 cylinder, 4 P, OHV

Bore x Stroke (mm) 86X70

Cylinder Displacement 418

Power (rpm/min) 10 HP / 3600

Compression Rate 8,5:1

Engine Speed 3000

Starting System ELECTRIC STARTER

Fuel Type Diesel

Oil Capacity (L) 1,7

Fuel Tank Capacity (L) 16

Fuel Consumption g/kWh <280

GVD7000 DIESEL GENSET / 50Hz

GVD7000-3 DIESEL GENSET / 50Hz

STANDARD FEATURES:Open TypeAir cooled engineAutomatic engine stop by low oil level1 unit mono phase output socketsStarting BatteriesStrong Baseframe with wheels

STANDARD FEATURES:Open TypeAvir cooled engineAutomatic engine stop by low oil level1 unit three phase output socketsStarting BatteriesStrong Baseframe with wheels

179

www.grandvoltage.roPORTABLE GENSETS

OUTPUT RATINGS 50 HZ / 220 V

Maximum Power 7 kW

Prime Power 6,5 kW

OUTPUT RATINGS 50 HZ / 220 V

Maximum Power 7 kW

Prime Power 6,5 kW

ENGINE

Model 188FAE

Voltage (V) 110/240

Frequency (Hz) 50

Power Factor 1

Protection Class B

Voltage Control AVR

Output Socket 1 pcs (AC)

Dimensions (mm) (LxWxH) 915x547x742

Dry Weight (Kg) 170

Noise Level dba @ 7 mt 72

Engine Type 1 cylinder, 4 P

Bore x Stroke (mm) 86X70

Cylinder Displacement 418

Power (rpm/min) 10 HP / 3000

Compression Rate 8,5:1

Engine Speed 3000

Starting System ELECTRIC STARTER

Fuel Type Diesel

Oil Capacity (L) 1,7

Fuel Tank Capacity (L) 16

Fuel Consumption g/kWh <280

ENGINE

Model 188FAE

Voltage (V) 110/240

Frequency (Hz) 50

Power Factor 1

Protection Class B

Voltage Control AVR

Output Socket 1 pcs (AC)

Dimensions (mm) (LxWxH) 915x547x742

Dry Weight (Kg) 170

Noise Level dba @ 7 mt 72

Engine Type 1 cylinder, 4 P

Bore x Stroke (mm) 86X70

Cylinder Displacement 418

Power (rpm/min) 10 HP / 3000

Compression Rate 8,5:1

Engine Speed 3000

Starting System ELECTRIC STARTER

Fuel Type Diesel

Oil Capacity (L) 1,7

Fuel Tank Capacity (L) 16

Fuel Consumption g/kWh <280

GVD7000S DIESEL GENSET / 50Hz

GVD7000S-3 DIESEL GENSET / 50Hz

STANDARD FEATURES:Silent ( Canopy )Air cooled engineAutomatic engine stop by low oil level1 unit mono phase output socketsStarting BatteriesStrong Baseframe with wheels

STANDARD FEATURES:Silent ( Canopy )Air cooled engineAutomatic engine stop by low oil level1 unit three phase output socketsStarting BatteriesStrong Baseframe with wheels