Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code
OpenOrder Code
CanopiedSTAND-BY POWER
PRIME POWER
OPEN CANOPIED OPEN CANOPIED
GVP-G10 10 kVA 9 kVA 800x2000x1200 930x2100x1000 650 850 GV31464777 GV31464806
GVP-G15 15 kVA 13 kVA 800x2000x1200 930x2100x1000 650 850 GV31464778 GV31464807
GVP-G22 22 kVA 20 kVA 800x2000x1200 930x2100x1000 650 850 GV31464779 GV31464808
GVP-G33 33 kVA 30 kVA 900x1800x1420 950x2300x1720 792 1120 GV31464780 GV31464809
GVP-G50 50 kVA 42,5 kVA 900x1800x1420 900x2300x1720 859 1187 GV31464781 GV31464810
GVP-G66 66 kVA 60 kVA 900x1800x1420 900x2300x1720 890 1250 GV31464782 GV31464811
GVP-G72 72 kVA 65 kVA 900x1800x1420 900x2300x1720 945 1280 GV31464783 GV31464812
GVP-G88 88 kVA 80 kVA 1100x2100x1650 1100x2800x1830 955 1460 GV31464784 GV31464813
GVP-G110 110 kVA 100 kVA 1100x2100x1650 1100x2800x1830 1550 2235 GV31464785 GV31464814
GVP-G150 150 kVA 136 kVA 1100x2100x1650 1100x2800x1830 1600 2300 GV31464786 GV31464815
GVP-G165 165 kVA 150 kVA 1200x2800x1720 1200x2800x2220 2100 2750 GV31464787 GV31464816
GVP-G200 200 kVA 180 kVA 1200x2800x1720 1200x2800x2220 2115 2780 GV31464788 GV31464817
GVP-G220 220 kVA 200 kVA 1200x2800x1720 1200x2800x2220 2115 2780 GV31464789 GV31464818
GVP-G275 275 kVA 250 kVA 1500x2800x1720 1500x2800x2580 2021 3006 GV31464790 GV31464819
GVP-G300 300 kVA 275 kVA 1500x3100x1960 1500x4200x2580 2900 4000 GV314617400 GV314617402
GVP-G330 330 kVA 300 kVA 1500x2800x1720 1500x2800x2580 3004 4404 GV314617401 GV314617403
GVP-G400 400 kVA 350 kVA 1500x3100x1900 1500x4200x2580 3440 4400 GV31464791 GV31464820
GVP-G450 450 kVA 400 kVA 1500x3100x1900 1500x4200x2580 3520 4420 GV31464792 GV31464821
GVP-G500 500 kVA 455 kVA 1500x3500x2170 1500x4600x2810 3880 4780 GV31464793 GV31464822
GVP-G550 550 kVA 65 kVA 1500x3500x2170 1500x4600x2810 4070 5090 GV31464794 GV31464823
GVP-G660 660 kVA 600 kVA 1500x3500x2200 1500x4600x2810 4180 5090 GV31464795 GV31464824
GVP-G700 700 kVA 650 kVA 2100x3350x2200 2440x6060x2590 5070 7450 GV31464796 GV31464825
GVP-G825 825 kVA 750 kVA 2100x3350x2200 2440x6060x2590 6604 8414 GV31464797 GV31464826
GVP-G900 900 kVA 800 kVA 2100x3900x2220 2430x6050x2590 7264 9014 GV31464798 GV31464827
GVP-1000 1000 kVA 900 kVA 2100x4650x2550 2430x6050x2590 9300 11050 GV314622839 GV314622840
GVP-G1100 1100 kVA 1000 kVA 2100x4650x2550 2430x6050x2590 9610 11350 GV31464799 GV31464828
GVP-G1385 1385 kVA 1250 kVA 2100x4650x2550 2430x6050x2890 9720 15220 GV31464800 GV31464829
GVP-G1650 1650 kVA 1500 kVA 2400x5500x2690 2430x9080x3150 9920 16120 GV31464801 GV31464830
GVP-G1880 1880 kVA 1710 kVA 2400x5500x2690 2430x12190x3220 10700 19280 GV31464802 GV31464831
GVP-G2000 2000 kVA 1850 kVA 2430x6500x2690 3000x12190x3220 12145 20400 GV31464803 GV31464832
GVP-G2250 2250 kVA 2025 kVA 2430x6500x2690 3000x12190x3220 12350 20600 GV31464804 GV31464833
GVP-G2500 2500 kVA 2250 kVA 2430x6500x2690 3000x12190x3220 16300 20900 GV31464805 GV31464834
2
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power10 kVA
8 KW
Prime Power9 kVA
7,2 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 403A-11G1
No of Cylinder / Configuration 3 / IN LINE
Displacement (lt) 1,1
Bore / Stroke (mm) 77 / 81
Cycle 4
Compression Ratio 23 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 5,2
Lubrication Oil Capacity (lt) 4,9
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 8,5
Fuel Consumption (lt/h)100% 2,6
50% 2
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-12
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %82
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 930x2100x1000 850 100
OPEN SET 800x2000x1200 650 100
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G10 DIESEL GENERATOR SET / 50Hz
3
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power15 kVA
12 KW
Prime Power13 kVA
10,4 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 403A-15G1
No of Cylinder / Configuration 3 / IN LINE
Displacement (lt) 1,5
Bore / Stroke (mm) 84 / 90
Cycle 4
Compression Ratio 22.5 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 6
Lubrication Oil Capacity (lt) 6
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 12
Fuel Consumption (lt/h)100% 3,6
50% 2
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-15
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %83
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 930x2100x1000 850 100
OPEN SET 800x2000x1200 650 100
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G15 DIESEL GENERATOR SET / 50Hz
4
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power22 kVA
17,6 KW
Prime Power20 kVA
16 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 404A-22G1
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 2,2
Bore / Stroke (mm) 84 / 100
Cycle 4
Compression Ratio 23.3 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 7
Lubrication Oil Capacity (lt) 10,6
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 18,5
Fuel Consumption (lt/h)100% 5,3
50% 2.9
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-25
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %8
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 930x2100x1000 850 100
OPEN SET 800x2000x1200 650 100
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G22 DIESEL GENERATOR SET / 50Hz
5
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power33 kVA
26,4 KW
Prime Power30 kVA
24 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1103A-33G
No of Cylinder / Configuration 3 / IN LINE
Displacement (lt) 3,3
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 19.25 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 10,2
Lubrication Oil Capacity (lt) 8,3
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 27,7
Fuel Consumption (lt/h)100% 7,2
50% 4,06
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-33
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %88
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 950x2300x1720 1120 100
OPEN SET 900x1800x1420 792 100
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G33 DIESEL GENERATOR SET / 50Hz
6
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power50 kVA
40 KW
Prime Power45 kVA
36 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1103A-33TG1
No of Cylinder / Configuration 3 / IN LINE
Displacement (lt) 3,3
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 17.25 :1
Aspiration Turbo
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 10,2
Lubrication Oil Capacity (lt) 8,3
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 41,3
Fuel Consumption (lt/h)100% 10,8
50% 5,83
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-50
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %89
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 900x2300x1720 1185 200
OPEN SET 900x1800x1420 860 200
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G50 DIESEL GENERATOR SET / 50Hz
7
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power66 kVA
52,8 KW
Prime Power60 kVA
48 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1103A33TG2
No of Cylinder / Configuration 3 / IN LINE
Displacement (lt) 3,3
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 17.25 :1
Aspiration Turbo
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 10,2
Lubrication Oil Capacity (lt) 7,9
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 53,8
Fuel Consumption (lt/h)100% 14,6
50% 7,56
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-75
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %90
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 900x2300x1720 1250 200
OPEN SET 900x1800x1420 890 200
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G66 DIESEL GENERATOR SET / 50Hz
8
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power72 kVA
57,6 KW
Prime Power65 kVA
52 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1104A-44TG1
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,4
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 17.25 :1
Aspiration Turbo
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 13
Lubrication Oil Capacity (lt) 8
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 58,4
Fuel Consumption (lt/h)100% 14,8
50% 8
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-75
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %91
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 900x2300x1720 1280 200
OPEN SET 900x1800x1420 945 200
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G72 DIESEL GENERATOR SET / 50Hz
9
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power88 kVA
70,4 KW
Prime Power80 kVA
64 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1104A-44TG2
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,4
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 17.25: 1
Aspiration Turbo
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 13
Lubrication Oil Capacity (lt) 8
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 71,9
Fuel Consumption (lt/h)100% 18,7
50% 9,7
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-88
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %91
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1100x2800x1830 1460 200
OPEN SET 1100x2100x1650 955 200
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G88 DIESEL GENERATOR SET / 50Hz
10
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power110 kVA
88 KW
Prime Power100 kVA
80 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1104C-44TAG2
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,4
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 18.2 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 12,6
Lubrication Oil Capacity (lt) 8
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 89
Fuel Consumption (lt/h)100% 22,6
50%11,2
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-110
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %92
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1100x2800x1830 2235 240
OPEN SET 1100x2100x1650 1550 240
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G110 DIESEL GENERATOR SET / 50Hz
11
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power150 kVA
120 KW
Prime Power136 kVA
108,8 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1106A-70TG1
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6
Bore / Stroke (mm) 100 / 127
Cycle 4
Compression Ratio 17.0 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 37,2
Lubrication Oil Capacity (lt) 19
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 121
Fuel Consumption (lt/h)100% 31,5
50% 16,5
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-150
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %92,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1100x2800x1830 2300 240
OPEN SET 1100x2100x1650 1600 240
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G150 DIESEL GENERATOR SET / 50Hz
12
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power165 kVA
132 KW
Prime Power150 kVA
120 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1106A-70TAG2
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6
Bore / Stroke (mm) 100 / 127
Cycle 4
Compression Ratio 17.0 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 37,2
Lubrication Oil Capacity (lt) 19
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 133,2
Fuel Consumption (lt/h)100% 41
50% 20
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-165
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1200x2800x2220 2750 340
OPEN SET 1200x2800x1720 2100 340
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G165 DIESEL GENERATOR SET / 50Hz
13
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power200 kVA
160 KW
Prime Power180 kVA
144 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1106A-70TAG3
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,6
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 16.2 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 21
Lubrication Oil Capacity (lt) 16,5
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 158,4
Fuel Consumption (lt/h)100% 40,2
50% 20,5
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-200
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1200x2800x2220 2780 340
OPEN SET 1200x2800x1720 2115 340
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G200 DIESEL GENERATOR SET / 50Hz
14
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power220 kVA
176 KW
Prime Power200 kVA
160 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1106A-70TAG4
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 8,7
Bore / Stroke (mm) 116,6 / 135,9
Cycle 4
Compression Ratio 16.9 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 37,2
Lubrication Oil Capacity (lt) 28,3
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 174
Fuel Consumption (lt/h)100% 43,8
50% 26,4
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT 220
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1200x2800x2220 2780 400
OPEN SET 1200x2800x1720 2115 400
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G220 DIESEL GENERATOR SET / 50Hz
15
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power275 kVA
220 KW
Prime Power250 kVA
200 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1506A-E87TAG3
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 8,7
Bore / Stroke (mm) 116,6 / 135,9
Cycle 4
Compression Ratio 16.9 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 37,2
Lubrication Oil Capacity (lt) 28,3
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 217
Fuel Consumption (lt/h)100% 54
50% 31
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-275
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x2800x2580 3006 400
OPEN SET 1500x2800x1720 2021 400
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G275 DIESEL GENERATOR SET / 50Hz
16
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power300 kVA
240 KW
Prime Power275 kVA
220 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1506A-E87TAG4
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 9,3
Bore / Stroke (mm) 117 / 146
Cycle 4
Compression Ratio 16.9 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 33
Lubrication Oil Capacity (lt) 31
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 269
Fuel Consumption (lt/h)100% 71
50% 39
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-330
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4200x2580 4000 500
OPEN SET 1500x3100x1960 2900 500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G300 DIESEL GENERATOR SET / 50Hz
17
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power330 kVA
264 KW
Prime Power297 kVA
237 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1506A-E88TAG5
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 8,8
Bore / Stroke (mm) 112 / 149
Cycle 4
Compression Ratio 16.1 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 29,6
Lubrication Oil Capacity (lt) 41
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 293
Fuel Consumption (lt/h)100% 65
50% 33
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-330
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x2800x2580 4404 500
OPEN SET 1500x2800x1720 3004 500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G330 DIESEL GENERATOR SET / 50Hz
18
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power400 kVA
320 KW
Prime Power350 kVA
280 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 2206C-E13TAG2
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 13
Bore / Stroke (mm) 137 / 157
Cycle 4
Compression Ratio 16.3 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 51,4
Lubrication Oil Capacity (lt) 40
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 305
Fuel Consumption (lt/h)100% 71
50% 37
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-400
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4200x2580 4400 800
OPEN SET 1500x3100x1900 3440 800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G400 DIESEL GENERATOR SET / 50Hz
19
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power450 kVA
360 KW
Prime Power400 kVA
320 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 2206A-E13TAG3
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 13
Bore / Stroke (mm) 137 / 157
Cycle 4
Compression Ratio 16.3 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 51,4
Lubrication Oil Capacity (lt) 40
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 350
Fuel Consumption (lt/h)100% 81
50% 42
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-450
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4200x2580 4420 800
OPEN SET 1500x3100x1900 3520 800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G450 DIESEL GENERATOR SET / 50Hz
20
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power500 kVA
400 KW
Prime Power455 kVA
364 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 2506A-E15TAG1
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 15
Bore / Stroke (mm) 137 / 171
Cycle 4
Compression Ratio 16.0 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 58
Lubrication Oil Capacity (lt) 62
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 396
Fuel Consumption (lt/h)100% 95
50% 50
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-500
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %95
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4600x2810 4780 800
OPEN SET 1500x3500x2170 3880 800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G500 DIESEL GENERATOR SET / 50Hz
21
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power550 kVA
450 KW
Prime Power500 kVA
400 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 2506A-E15TAG2
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 15
Bore / Stroke (mm) 137 / 171
Cycle 4
Compression Ratio 16.0 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 58
Lubrication Oil Capacity (lt) 62
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 435
Fuel Consumption (lt/h)100% 106
50% 55
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-550
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %95
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4600x2810 5090 800
OPEN SET 1500x3500x2170 4070 800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G550 DIESEL GENERATOR SET / 50Hz
22
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power660 kVA
528 KW
Prime Power600 kVA
480 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 2806A-E18TAG1A
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 18
Bore / Stroke (mm) 145 / 183
Cycle 4
Compression Ratio 14.5 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 61
Lubrication Oil Capacity (lt) 62
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 522
Fuel Consumption (lt/h)100% 122
50% 61
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-660
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %95
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4600x2810 5090 1500
OPEN SET 1500x3500x2200 4180 1500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G660 DIESEL GENERATOR SET / 50Hz
23
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power700 kVA
560 KW
Prime Power650 kVA
520 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 2806A-E18TAG2
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 18
Bore / Stroke (mm) 145 / 183
Cycle 4
Compression Ratio 14.5 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 61
Lubrication Oil Capacity (lt) 62
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 565
Fuel Consumption (lt/h)100% 125
50% 63
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-700
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %95
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2440x6060x2590 7450 1500
OPEN SET 2100x3350x2200 5070 1500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G700 DIESEL GENERATOR SET / 50Hz
24
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power825 kVA
660 KW
Prime Power750 kVA
600 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4006-23TAG2A
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 23
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 105
Lubrication Oil Capacity (lt) 113,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 632
Fuel Consumption (lt/h)100% 155
50% 80
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-850
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %95
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2440x6060x2590 8414 1500
OPEN SET 2100x3350x2200 6604 1500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G825 DIESEL GENERATOR SET / 50Hz
25
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power900 kVA
720 KW
Prime Power800 kVA
640 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4006-23TAG3A
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 23
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 105
Lubrication Oil Capacity (lt) 113,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 679
Fuel Consumption (lt/h)100% 172
50% 90
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-950
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2590 9010 1500
OPEN SET 2100x3900x2220 7260 1500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G900 DIESEL GENERATOR SET / 50Hz
26
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1000 kVA
800 KW
Prime Power900 kVA
720 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4008-TAG1A
No of Cylinder / Configuration 8 / IN LINE
Displacement (lt) 30
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 143
Lubrication Oil Capacity (lt) 153
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 882
Fuel Consumption (lt/h)100% 195
50% 98
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-1000
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %95
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2590 11050 2000
OPEN SET 2100x4650x2550 9300 2000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G1000 DIESEL GENERATOR SET / 50Hz
27
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1100 kVA
880 KW
Prime Power990 kVA
792 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4008-TAG2A
No of Cylinder / Configuration 8 / IN LINE
Displacement (lt) 30
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.60 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 149
Lubrication Oil Capacity (lt) 153
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 861
Fuel Consumption (lt/h)100% 226
50% 130
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-1100
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %95,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2590 11350 2400
OPEN SET 2100x4650x2550 9600 2400
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G1100 DIESEL GENERATOR SET / 50Hz
28
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1385 kVA
1108 KW
Prime Power1250 kVA
1000 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4012-46TWG2A
No of Cylinder / Configuration 12 / V
Displacement (lt) 45
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 159
Lubrication Oil Capacity (lt) 201
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1055
Fuel Consumption (lt/h)100% 259
50% 143
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-1500
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %95,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2890 15220 2800
OPEN SET 2100x4650x2550 9720 2800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G1385 DIESEL GENERATOR SET / 50Hz
29
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1650 kVA
1320 KW
Prime Power1500 kVA
1204 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4012-46TAG2A
No of Cylinder / Configuration 12 / V
Displacement (lt) 46
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.00 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 177
Lubrication Oil Capacity (lt) 240
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1267
Fuel Consumption (lt/h)100% 301
50% 165
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-1670
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %96
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x9080x3150 16120 3000
OPEN SET 2400x5500x2690 9920 3000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G1650 DIESEL GENERATOR SET / 50Hz
30
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1880 kVA
1504 KW
Prime Power1710 kVA
1368 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 401246TAG3A
No of Cylinder / Configuration 12 / V
Displacement (lt) 46
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 177
Lubrication Oil Capacity (lt) 210
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1440
Fuel Consumption (lt/h)100% 370
50% 187
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-2000
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x12190x3220 19280 3000
OPEN SET 2400x5500x2690 10700 3000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G1880 DIESEL GENERATOR SET / 50Hz
31
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power2000 kVA
1622 KW
Prime Power1850 kVA
1476 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4016TAG1A
No of Cylinder / Configuration 16 / V
Displacement (lt) 46
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 237,2
Lubrication Oil Capacity (lt) 316
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1537
Fuel Consumption (lt/h)100% 370
50% 191
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-2000
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %97
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 3000x12190x3220 20400 3400
OPEN SET 2430x6500x2690 12145 3400
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G2000 DIESEL GENERATOR SET / 50Hz
32
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power2250 kVA
1800 KW
Prime Power2025 kVA
1620 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4016-TAG2A
No of Cylinder / Configuration 16 / V
Displacement (lt) 46
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 237,2
Lubrication Oil Capacity (lt) 316
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1715
Fuel Consumption (lt/h)100% 421
50% 217
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-2250
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %97
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 3000x12190x3220 20600 3500
OPEN SET 2430x6500x2690 12350 3500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G2250 DIESEL GENERATOR SET / 50Hz
33
www.grandvoltage.roPERKINS – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power2500 kVA
2000 KW
Prime Power2250 kVA
1800 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4016-61TRG3
No of Cylinder / Configuration 16 / V
Displacement (lt) 61.123
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 270
Lubrication Oil Capacity (lt) 237
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1975
Fuel Consumption (lt/h)100% 470
50% 234
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-2500
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %97
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 3000x12190x3220 20900 3500
OPEN SET 2430x6500x2690 16300 3500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-G2500 DIESEL GENERATOR SET / 50Hz
34
Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code
OpenOrder Code
CanopiedSTAND-BY POWER
PRIME POWER
OPEN CANOPIED OPEN CANOPIED
GVP-S10 10 kVA 9 kVA 800x2000x1200 930x2100x1000 650 850 GV31464835 GV31464864
GVP-S15 15 kVA 13 kVA 800x2000x1200 930x2100x1000 650 850 GV31464836 GV31464865
GVP-S22 22 kVA 20 kVA 800x2000x1200 745x2000x1400 650 850 GV31464837 GV31464866
GVP-S33 33 kVA 30 kVA 900x1800x1420 950x2300x1720 792 1120 GV31464838 GV31464867
GVP-S50 50 kVA 42,5 kVA 900x1800x1420 900x2300x1720 859 1187 GV31464839 GV31464868
GVP-S66 66 kVA 60 kVA 900x1800x1420 900x2300x1720 890 1250 GV31464840 GV31464869
GVP-S72 72 kVA 65 kVA 900x1800x1420 900x2300x1720 945 1280 GV31464841 GV31464870
GVP-S88 88 kVA 80 kVA 1100x2100x1650 1100x2800x1830 955 1460 GV31464842 GV31464871
GVP-S110 110 kVA 100 kVA 1100x2100x1650 1100x2800x1830 1550 2235 GV31464843 GV31464872
GVP-S150 150 kVA 136 kVA 1100x2100x1650 1100x2800x1830 1600 2300 GV31464844 GV31464873
GVP-S165 165 kVA 150 kVA 1200x2800x1720 1200x2800x2220 2100 2750 GV31464845 GV31464874
GVP-S200 200 kVA 180 kVA 1200x2800x1720 1200x2800x2220 2115 2780 GV31464846 GV31464875
GVP-S220 220 kVA 208 kVA 1200x2800x1720 1200x2800x2220 2115 2780 GV31464847 GV31464876
GVP-S250 250 kVA 227 kVa 1500x2800x1720 1500x2800x2580 2120 3100 GV314617404 GV314617406
GVP-S275 275 kVA 250 kVA 1500x2800x1720 1500x2800x2580 2021 3006 GV31464848 GV31464877
GVP-S300 300 kVA 275 kVA 1500x3100x1960 1500x4200x2580 2900 4000 GV314617405 GV314617407
GVP-S400 400 kVA 350 kVA 1500x3100x1900 1500x4200x2580 3440 4400 GV31464849 GV31464878
GVP-S450 450 kVA 400 kVA 1500x3100x1900 1500x4200x2580 3520 4420 GV31464850 GV31464879
GVP-S500 500 kVA 455 kVA 1500x3500x2170 1500x4600x2810 3880 4780 GV31464851 GV31464880
GVP-S550 550 kVA 65 kVA 1500x3500x2170 1500x4600x2810 4070 5090 GV31464852 GV31464881
GVP-S660 660 kVA 600 kVA 1500x3500x2200 1500x4600x2810 4180 5090 GV31464853 GV31464882
GVP-S700 700 kVA 650 kVA 2100x3350x2200 2440x6060x2590 5070 7450 GV31464854 GV31464883
GVP-S825 825 kVA 750 kVA 2100x3350x2200 2440x6060x2590 6604 8414 GV31464855 GV31464884
GVP-S900 900 kVA 800 kVA 2100x3900x2220 2430x6050x2590 7264 9014 GV31464856 GV31464885
GVP-S1000 1000 kVA 900 kVA 2100x4650x2550 2430x6050x2590 9303 11053 GV314622841 GV314622842
GVP-S1100 1100 kVA 990 kVA 2100x4650x2550 2430x6050x2590 9610 11350 GV31464857 GV31464886
GVP-S1385 1385 kVA 1250 kVA 2100x4650x2550 2430x6050x2890 9720 15220 GV31464858 GV31464887
GVP-S1650 1650 kVA 1500 kVA 2400x5500x2690 2430x9080x3150 9920 16120 GV31464859 GV31464888
GVP-S1880 1880 kVA 1710 kVA 2400x5500x2690 2430x12190x3220 10700 19280 GV31464860 GV31464889
GVP-S2000 2000 kVA 1850 kVA 2430x6500x2690 3000x12190x3220 12145 20400 GV31464861 GV31464890
GVP-S2250 2250 kVA 2025 kVA 2430x6500x2690 3000x12190x3220 12350 20600 GV31464862 GV31464891
GVP-S2500 2500 kVA 2250 kVA 2430x6500x2690 3000x12190x3220 16300 20900 GV31464863 GV31464892
35
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power10 kVA
8 KW
Prime Power9 kVA
7,2 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 403A-11G1
No of Cylinder / Configuration 3 / IN LINE
Displacement (lt) 1,1
Bore / Stroke (mm) 77 / 81
Cycle 4
Compression Ratio 23 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 5,2
Lubrication Oil Capacity (lt) 4,9
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 8,5
Fuel Consumption (lt/h)100% 2,6
50% 2
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model PIO44E
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %80,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 930x2100x1000 850 100
OPEN SET 800x2000x1200 650 100
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S10 DIESEL GENERATOR SET / 50Hz
36
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power15 kVA
12 KW
Prime Power13 kVA
10,4 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 403A-15G1
No of Cylinder / Configuration 3 / IN LINE
Displacement (lt) 1,5
Bore / Stroke (mm) 84 / 90
Cycle 4
Compression Ratio 22.5 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 6
Lubrication Oil Capacity (lt) 6
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 12
Fuel Consumption (lt/h)100% 3,6
50% 2
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model PIO44F
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %82,1
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 930x2100x1000 850 100
OPEN SET 800x2000x1200 650 100
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S15 DIESEL GENERATOR SET / 50Hz
37
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power22 kVA
17,6 KW
Prime Power20 kVA
16 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 404A-22G1
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 2,2
Bore / Stroke (mm) 84 / 100
Cycle 4
Compression Ratio 23.3 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 7
Lubrication Oil Capacity (lt) 10,6
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 18,5
Fuel Consumption (lt/h)100% 5,3
50% 2,9
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model PIO144D
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %85,1
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 930x2100x1000 850 100
OPEN SET 800x2000x1200 650 100
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S22 DIESEL GENERATOR SET / 50Hz
38
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power33 kVA
26,4 KW
Prime Power30 kVA
24 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1103A-33G
No of Cylinder / Configuration 3 / IN LINE
Displacement (lt) 3,3
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 19.25 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 10,2
Lubrication Oil Capacity (lt) 8,3
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 27,7
Fuel Consumption (lt/h)100% 7,1
50% 4,06
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model PIO144G
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %86,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 950x2300x1720 1120 100
OPEN SET 900x1800x1420 790 100
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S33 DIESEL GENERATOR SET / 50Hz
39
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power50 kVA
40 KW
Prime Power45 kVA
36 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1103A-33TG1
No of Cylinder / Configuration 3 / IN LINE
Displacement (lt) 3,3
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 17.25 :1
Aspiration Turbo
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 10,2
Lubrication Oil Capacity (lt) 8,3
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 41,3
Fuel Consumption (lt/h)100% 10,8
50% 5,83
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model UCI224D
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %88,2
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 900x2300x1720 1180 150
OPEN SET 900x1800x1420 860 150
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S50 DIESEL GENERATOR SET / 50Hz
40
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power66 kVA
52,8 KW
Prime Power60 kVA
48 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1103A-33TG2
No of Cylinder / Configuration 3 / IN LINE
Displacement (lt) 3,3
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 17.25 :1
Aspiration Turbo
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 10,2
Lubrication Oil Capacity (lt) 7,9
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 53,8
Fuel Consumption (lt/h)100% 14,6
50% 7,56
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model UCI224E
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %88,2
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 900x2300x1720 1250 150
OPEN SET 900x1800x1420 890 150
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVZP-S66 DIESEL GENERATOR SET / 50Hz
41
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power72 kVA
57,6 KW
Prime Power65 kVA
52 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1104A-44TG1
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,4
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 17.25 :1
Aspiration Turbo
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 13
Lubrication Oil Capacity (lt) 8
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 58,4
Fuel Consumption (lt/h)100% 14,8
50% 8
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model UCI224F
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %89,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 900x2300x1720 1280 270
OPEN SET 900x1800x1420 945 270
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S72 DIESEL GENERATOR SET / 50Hz
42
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power88 kVA
70,4 KW
Prime Power80 kVA
64 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1104A-44TG2
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,4
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 17.25: 1
Aspiration Turbo
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 13
Lubrication Oil Capacity (lt) 8
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 71
Fuel Consumption (lt/h)100% 18,7
50% 9,7
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model UCI224G
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %90,2
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1100x2800x1830 1460 270
OPEN SET 1100x2100x1650 955 270
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S88 DIESEL GENERATOR SET / 50Hz
43
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power110 kVA
88 KW
Prime Power100 kVA
80 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1104C-44TAG2
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,4
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 18.2 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 12,6
Lubrication Oil Capacity (lt) 8
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 89
Fuel Consumption (lt/h)100% 22,6
50% 11,2
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model UCI274C
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %90,2
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1100x2800x1830 2235 270
OPEN SET 1100x2100x1650 1550 270
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S110 DIESEL GENERATOR SET / 50Hz
44
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power150 kVA
120 KW
Prime Power136 kVA
108,8 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1106A-70TG1
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6
Bore / Stroke (mm) 100 / 127
Cycle 4
Compression Ratio 17.0 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 37,2
Lubrication Oil Capacity (lt) 19
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 121
Fuel Consumption (lt/h)100% 31,5
50% 16,5
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model UCI274E
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %92,4
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1100x2800x1830 2300 400
OPEN SET 1100x2100x1650 1600 400
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S150 DIESEL GENERATOR SET / 50Hz
45
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power165 kVA
132 KW
Prime Power150 kVA
120 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1106A-70TAG2
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6
Bore / Stroke (mm) 100 / 127
Cycle 4
Compression Ratio 17.0 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 37,2
Lubrication Oil Capacity (lt) 19
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 133,2
Fuel Consumption (lt/h)100% 41
50% 20
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model UCI274F
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %91,7
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1200x2800x2220 2750 400
OPEN SET 1200x2800x1720 2100 400
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S165 DIESEL GENERATOR SET / 50Hz
46
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power200 kVA
160 KW
Prime Power180 kVA
144 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1106A-70TAG3
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,6
Bore / Stroke (mm) 105 / 127
Cycle 4
Compression Ratio 16.2 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 21
Lubrication Oil Capacity (lt) 16,5
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 158,4
Fuel Consumption (lt/h)100% 40,2
50% 20,5
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model UCI274G
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %92,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1200x2800x2220 2780 400
OPEN SET 1200x2800x1720 2115 400
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S200 DIESEL GENERATOR SET / 50Hz
47
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power220 kVA
176 KW
Prime Power200 kVA
160 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1106A-70TAG4
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 8,7
Bore / Stroke (mm) 116,6 / 135,9
Cycle 4
Compression Ratio 16.9 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 37,2
Lubrication Oil Capacity (lt) 28,3
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 174
Fuel Consumption (lt/h)100% 43,8
50% 26,4
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model UCI274H
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1200x2800x2220 2780 570
OPEN SET 1200x2800x1720 2115 570
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S220 DIESEL GENERATOR SET / 50Hz
48
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power250 kVA
200 KW
Prime Power227 kVA
182 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1506A-E87TAG2
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 8,7
Bore / Stroke (mm) 116,6 / 135,9
Cycle 4
Compression Ratio 16.9 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 37,2
Lubrication Oil Capacity (lt) 28,3
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 217
Fuel Consumption (lt/h)100% 54
50% 31
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model HC444E
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x2800x2580 3100 570
OPEN SET 1500x2800x1720 2120 570
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S250 DIESEL GENERATOR SET / 50Hz
49
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power275 kVA
220 KW
Prime Power250 kVA
200 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1506A-E87TAG3
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 8,7
Bore / Stroke (mm) 116,6 / 135,9
Cycle 4
Compression Ratio 16.9 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 37,2
Lubrication Oil Capacity (lt) 28,3
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 217
Fuel Consumption (lt/h)100% 54
50% 31
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model HC444E
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x2800x2580 3006 570
OPEN SET 1500x2800x1720 2021 570
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S275 DIESEL GENERATOR SET / 50Hz
50
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power300 kVA
240 KW
Prime Power275 kVA
220 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 1506A-E87TAG4
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 9,3
Bore / Stroke (mm) 117 / 146
Cycle 4
Compression Ratio 16.9 :1
Aspiration Turbo
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 33
Lubrication Oil Capacity (lt) 31
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 269
Fuel Consumption (lt/h)100% 71
50% 39
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model HCI444D
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4200x2580 4000 570
OPEN SET 1500x3100x1960 2900 570
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S300 DIESEL GENERATOR SET / 50Hz
51
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power400 kVA
320 KW
Prime Power350 kVA
280 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 2206C-E13TAG2
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 13
Bore / Stroke (mm) 137 / 157
Cycle 4
Compression Ratio 16.3 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 51,4
Lubrication Oil Capacity (lt) 40
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 305
Fuel Consumption (lt/h)100% 71
50% 37
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model HC444E
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4200x2580 4400 1000
OPEN SET 1500x3100x1900 3440 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S400 DIESEL GENERATOR SET / 50Hz
52
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power450 kVA
360 KW
Prime Power400 kVA
320 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 2206A-E13TAG3
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 13
Bore / Stroke (mm) 137 / 157
Cycle 4
Compression Ratio 16.3 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 51,4
Lubrication Oil Capacity (lt) 40
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 350
Fuel Consumption (lt/h)100% 81
50% 42
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model HC444F
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4200x2580 4420 1000
OPEN SET 1500x3100x1900 3520 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S450 DIESEL GENERATOR SET / 50Hz
53
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power500 kVA
400 KW
Prime Power455 kVA
364 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 2506A-E15TAG1
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 15
Bore / Stroke (mm) 137 / 171
Cycle 4
Compression Ratio 16.0 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 58
Lubrication Oil Capacity (lt) 62
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 396
Fuel Consumption (lt/h)100% 95
50% 50
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model HC544C
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4600x2810 4780 1000
OPEN SET 1500x3500x2170 3880 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S500 DIESEL GENERATOR SET / 50Hz
54
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power550 kVA
450 KW
Prime Power500 kVA
400 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 2506CA-E15TAG2
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 15
Bore / Stroke (mm) 137 / 171
Cycle 4
Compression Ratio 16.0 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 58
Lubrication Oil Capacity (lt) 62
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 435
Fuel Consumption (lt/h)100% 106
50% 55
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model HC544C
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4600x2810 5090 1000
OPEN SET 1500x3500x2170 4070 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S550 DIESEL GENERATOR SET / 50Hz
55
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power660 kVA
528 KW
Prime Power600 kVA
480 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 2806A-E18TAG1A
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 18
Bore / Stroke (mm) 145 / 183
Cycle 4
Compression Ratio 14.5 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 61
Lubrication Oil Capacity (lt) 62
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 522
Fuel Consumption (lt/h)100% 122
50% 61
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model HCI544E
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,1
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4600x2810 5090 1500
OPEN SET 1500x3500x2200 4180 1500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S660 DIESEL GENERATOR SET / 50Hz
56
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power700 kVA
560 KW
Prime Power650 kVA
520 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 2806A-E18TAG2
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 18
Bore / Stroke (mm) 145 / 183
Cycle 4
Compression Ratio 14.5 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 61
Lubrication Oil Capacity (lt) 62
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 565
Fuel Consumption (lt/h)100% 125
50% 63
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model HC544F
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2440x6060x2590 7450 1500
OPEN SET 2100x3350x2200 5070 1500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S700 DIESEL GENERATOR SET / 50Hz
57
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power825 kVA
660 KW
Prime Power750 kVA
600 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4006-23TAG2A
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 23
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 105
Lubrication Oil Capacity (lt) 113,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 632
Fuel Consumption (lt/h)100% 161
50% 80
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model HCI634G
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2440x6060x2590 8414 1500
OPEN SET 2100x3350x2200 6604 1500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S825 DIESEL GENERATOR SET / 50Hz
58
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power900 kVA
720 KW
Prime Power800 kVA
640 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4006-23TAG3A
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 23
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 105
Lubrication Oil Capacity (lt) 113,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 679
Fuel Consumption (lt/h)100% 172
50% 90
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model HCI634G
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2590 9014 1500
OPEN SET 2100x3900x2220 7264 1500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S900 DIESEL GENERATOR SET / 50Hz
59
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1000 kVA
800 KW
Prime Power900 kVA
720 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4008-TAG1A
No of Cylinder / Configuration 8 / IN LINE
Displacement (lt) 30
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 143
Lubrication Oil Capacity (lt) 153
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 882
Fuel Consumption (lt/h)100% 195
50% 98
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model HCI 634H
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %95
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2590 11053 2000
OPEN SET 2100x4650x2550 9303 2000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S1000 DIESEL GENERATOR SET / 50Hz
60
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1100 kVA
880 KW
Prime Power990 kVA
792 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4008-TAG2A
No of Cylinder / Configuration 8 / IN LINE
Displacement (lt) 30
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 149
Lubrication Oil Capacity (lt) 153
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 861
Fuel Consumption (lt/h)100% 226
50% 130
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model HCI634J
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2590 11350 2000
OPEN SET 2100x4650x2550 9610 2000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S1100 DIESEL GENERATOR SET / 50Hz
61
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1385 kVA
1108 KW
Prime Power1250 kVA
1000 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4012-46TWG2A
No of Cylinder / Configuration 12 / V
Displacement (lt) 45
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 159
Lubrication Oil Capacity (lt) 201
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1055
Fuel Consumption (lt/h)100% 259
50% 143
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model PI734A
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2890 15220 EXTERNAL
OPEN SET 2100x4650x2550 9720 EXTERNAL
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S1385 DIESEL GENERATOR SET / 50Hz
62
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1650 kVA
1320 KW
Prime Power1500 kVA
1204 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4012-46TAG2A
No of Cylinder / Configuration 12 / V
Displacement (lt) 46
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.00 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 177
Lubrication Oil Capacity (lt) 240
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1267
Fuel Consumption (lt/h)100% 301
50% 165
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model PI734C
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0.5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x9080x3150 16120 EXTERNAL
OPEN SET 2400x5500x2690 9920 EXTERNAL
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S1650 DIESEL GENERATOR SET / 50Hz
63
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1880 kVA
1504 KW
Prime Power1710 kVA
1368 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4012-46TAG3A
No of Cylinder / Configuration 12 / V
Displacement (lt) 46
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 177
Lubrication Oil Capacity (lt) 210
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1440
Fuel Consumption (lt/h)100% 370
50% 187
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model PI734E
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x12190x3220 19280 EXTERNAL
OPEN SET 2400x5500x2690 10700 EXTERNAL
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S1880 DIESEL GENERATOR SET / 50Hz
64
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power2000 kVA
1622 KW
Prime Power1850 kVA
1476 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4016-TAG1A
No of Cylinder / Configuration 16 / V
Displacement (lt) 46
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 237,2
Lubrication Oil Capacity (lt) 316
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1537
Fuel Consumption (lt/h)100% 370
50% 191
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model PI734E
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 3000x12190x3220 20400 EXTERNAL
OPEN SET 2430x6500x2690 12145 EXTERNAL
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S2000 DIESEL GENERATOR SET / 50Hz
65
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power2250 kVA
1800 KW
Prime Power2025 kVA
1620 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4016-TAG2A
No of Cylinder / Configuration 16 / V
Displacement (lt) 46
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 237,2
Lubrication Oil Capacity (lt) 316
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1715
Fuel Consumption (lt/h)100% 421
50% 217
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model PI734G
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 3000x12190x3220 20600 EXTERNAL
OPEN SET 2430x6500x2690 12350 EXTERNAL
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP-S2250 DIESEL GENERATOR SET / 50Hz
66
www.grandvoltage.roPERKINS – STAMFORD
OUTPUT RATINGS 50 HZ / 400 V
Standby Power2500 kVA
2000 KW
Prime Power2250 kVA
1800 KW
ENGINE (ESP -STAND-BY)
Manufacturer PERKINS
Origin UK
Model 4016-61TRG3
No of Cylinder / Configuration 16 / V
Displacement (lt) 61.123
Bore / Stroke (mm) 160 / 190
Cycle 4
Compression Ratio 13.6 :1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 270
Lubrication Oil Capacity (lt) 237
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1975
Fuel Consumption (lt/h)100% 470
50% 234
ALTERNATOR
Manufacturer STAMFORD
Origin UK
Model N/A
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 3000x12190x3220 20900 EXTERNAL
OPEN SET 2430x6500x2690 16300 EXTERNAL
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVP--S2500 DIESEL GENERATOR SET / 50Hz
67
Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code
OpenOrder Code
CanopiedSTAND-BY POWER
PRIME POWER
OPEN CANOPIED OPEN CANOPIED
GVDO-G220 220 kVA 200 kVA 1150x2690x1620 1220x3400x1940 1800 2175 GV31464893 GV31464904
GVDO-G275 275 kVA 250 kVA 1300x3020x1600 1360x3960x2100 2265 2950 GV31464894 GV31464905
GVDO-G330 330 kVA 300 kVA 1300x2950x1588 1360x3960x2100 2375 3065 GV31464895 GV31464906
GVDO-G410 410 kVA 375 kVA 1550x3030x1994 1610x4460x2480 3030 4024 GV31464896 GV31464907
GVDO-G490 485 kVA 425 kVA 1550x3110x1994 1610x4460x2480 3130 4150 GV31464897 GV31464908
GVDO-G510 510 kVA 460 kVA 1550x3110x1994 1610x4460x2480 3080 4100 GV31464898 GV31464909
GVDO-G580 580 kVA 525 kVA 1550x3110x1990 1610x4460x2480 3350 4200 GV31464899 GV31464910
GVDO-G630 630 kVA 575 kVA 1550x3260x2060 1610x4810x2620 3720 4835 GV31464900 GV31464911
GVDO-G710 710 kVA 640 kVA 1550x3360x2060 1610x4810x2620 4000 4940 GV31464901 GV31464912
GVDO-G750 750 kVA 680 kVA 1550x3494x2301 1610x5300x2660 4190 5400 GV31464902 GV31464913
GVDO-G825 825 kVA 750 kVA 1550x3630x2301 1610x5300x2660 4320 5535 GV31464903 GV31464914
68
www.grandvoltage.roDOOSAN – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power220 kVA
176 KW
Prime Power200 kVA
160 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model P086TI
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 8,07
Bore / Stroke (mm) 111 / 139
Cycle 4
Compression Ratio 16,4. :1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 46
Lubrication Oil Capacity (lt) 15,5
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 199
Fuel Consumption (lt/h)100% 43,1
50% 21,1
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-220
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1220x3400x1940 2175 380
OPEN SET 1150x2690x1620 1800 380
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G220 DIESEL GENERATOR SET / 50Hz
69
www.grandvoltage.roDOOSAN – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power275 kVA
220 KW
Prime Power250 kVA
200 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model P126TI
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 11,05
Bore / Stroke (mm) 123 / 155
Cycle 4
Compression Ratio 17.1 :1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 52
Lubrication Oil Capacity (lt) 23
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 272
Fuel Consumption (lt/h)100% 53,3
50% 27,5
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-275
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1360x3960x2100 2940 470
OPEN SET 1300x3020x1600 2265 450
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G275 DIESEL GENERATOR SET / 50Hz
70
www.grandvoltage.roDOOSAN – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power330 kVA
264 KW
Prime Power300 kVA
240 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model P126TI-II
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 11,05
Bore / Stroke (mm) 123 / 155
Cycle 4
Compression Ratio 17.1 :1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 52
Lubrication Oil Capacity (lt) 23
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 294
Fuel Consumption (lt/h)100% 63,1
50% 31,3
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-330
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,8
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1360x3960x2100 3065 470
OPEN SET 1300x2950x1588 2375 450
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G330 DIESEL GENERATOR SET / 50Hz
71
www.grandvoltage.roDOOSAN – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power410 kVA
328 KW
Prime Power375 kVA
300 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model P158LE-1
No of Cylinder / Configuration 8 / V TYPE
Displacement (lt) 14,60
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0 :1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 68,5
Lubrication Oil Capacity (lt) 21
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 362
Fuel Consumption (lt/h)100% 78,7
50% 40
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-430
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x4460x2480 4024 700
OPEN SET 1550x3030x1994 3030 700
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G410 DIESEL GENERATOR SET / 50Hz
72
www.grandvoltage.roDOOSAN – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power485 kVA
388 KW
Prime Power425 kVA
340 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model P158LE
No of Cylinder / Configuration 8 / V TYPE
Displacement (lt) 14,60
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 68,5
Lubrication Oil Capacity (lt) 21
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 414
Fuel Consumption (lt/h)100% 89,3
50% 43,9
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-500
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x4460x2480 4150 700
OPEN SET 1550x3110x1994 3130 700
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G490 DIESEL GENERATOR SET / 50Hz
73
www.grandvoltage.roDOOSAN – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power510 kVA
408 KW
Prime Power460 kVA
368 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model DP158LC
No of Cylinder / Configuration 8 / V TYPE
Displacement (lt) 14,618
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 90
Lubrication Oil Capacity (lt) 22
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 449
Fuel Consumption (lt/h)100% 99,6
50% 48,9
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-550
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x4460x2480 4100 700
OPEN SET 1550x3110x1994 3080 700
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G510 DIESEL GENERATOR SET / 50Hz
74
www.grandvoltage.roDOOSAN – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power580 kVA
464 KW
Prime Power525 kVA
420 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model DP158LD
No of Cylinder / Configuration 8 / V TYPE
Displacement (lt) 14,61
Bore / Stroke (mm) 128 / 142
Cycle 4
Compression Ratio 15.0:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 90
Lubrication Oil Capacity (lt) 22
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 510
Fuel Consumption (lt/h)100% 115,1
50% 55,1
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-600
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x4460x2480 4200 850
OPEN SET 1550x3110x1990 3030 850
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G580 DIESEL GENERATOR SET / 50Hz
75
www.grandvoltage.roDOOSAN – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power630 kVA
504 KW
Prime Power575 kVA
460 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model DP180LA
No of Cylinder / Configuration 10 / V TYPE
Displacement (lt) 18,273
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0 :1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 112,2
Lubrication Oil Capacity (lt) 34
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 552
Fuel Consumption (lt/h)100% 123,6
50% 64,8
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-660
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x4810x2620 4835 850
OPEN SET 1550x3260x2060 3720 850
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G630 DIESEL GENERATOR SET / 50Hz
76
www.grandvoltage.roDOOSAN – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power710 kVA
568 KW
Prime Power640 kVA
512 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model DP180LB
No of Cylinder / Configuration 10 / V TYPE
Displacement (lt) 18,273
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 112
Lubrication Oil Capacity (lt) 34
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 612
Fuel Consumption (lt/h)100% 136,4
50% 71,2
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-750
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x4810x2620 4940 850
OPEN SET 1550x3360x2060 4000 850
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G710 DIESEL GENERATOR SET / 50Hz
77
www.grandvoltage.roDOOSAN – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power750 kVA
600 KW
Prime Power680 kVA
544 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model DP222LB
No of Cylinder / Configuration 12 / V TYPE
Displacement (lt) 21,93
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 134,8
Lubrication Oil Capacity (lt) 40
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 664
Fuel Consumption (lt/h)100% 147
50% 73
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-750
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x5300x2660 5400 1000
OPEN SET 1550x3494x2301 4190 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G750 DIESEL GENERATOR SET / 50Hz
78
www.grandvoltage.roDOOSAN – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power825 kVA
660 KW
Prime Power750 kVA
600 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model DP222LC
No of Cylinder / Configuration 12 / V TYPE
Displacement (lt) 21,93
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 134,8
Lubrication Oil Capacity (lt) 40
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 723
Fuel Consumption (lt/h)100% 161
50% 79,3
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-850
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x5300x2660 5535 1000
OPEN SET 1550x3630x2301 4320 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G825 DIESEL GENERATOR SET / 50Hz
79
GVDO-M220 220 kVA 200 kVA 1150x2688x1624 1217x3400x1938 1800 2175 GV31464915 GV31464926
GVDO-M275 275 kVA 250 kVA 1300x3020x1600 1360x3960x2100 2265 2950 GV31464916 GV31464927
GVDO-M330 330 kVA 300 kVA 1300x2950x1588 1360x3960x2100 2375 3065 GV31464917 GV31464928
GVDO-M410 410 kVA 375 kVA 1550x3030x1994 1610x4460x2480 3030 4024 GV31464918 GV31464929
GVDO-M490 485 kVA 425 kVA 1550x3110x1994 1610x4460x2480 3130 4150 GV31464919 GV31464930
GVDO-M510 510 kVA 460 kVA 1550x3110x1994 1610x4460x2480 3080 4100 GV31464920 GV31464931
GVDO-M580 580 kVA 525 kVA 1550x3110x1990 1610x4460x2480 3030 4200 GV31464921 GV31464932
GVDO-M630 630 kVA 575 kVA 1550x3260x2060 1610x4810x2620 3720 4835 GV31464922 GV31464933
GVDO-M710 710 kVA 640 kVA 1550x3360x2060 1610x4810x2620 4000 4940 GV31464923 GV31464934
GVDO-M750 750 kVA 680 kVA 1550x3494x2301 1610x5300x2660 4190 5400 GV31464924 GV31464935
GVDO-M825 825 kVA 750 kVA 1550x3630x2301 1610x5300x2660 4320 5535 GV31464925 GV31464936
Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code
OpenOrder Code
CanopiedSTAND-BY POWER
PRIME POWER
OPEN CANOPIED OPEN CANOPIED
80
www.grandvoltage.roDOOSAN – MECCALTE
OUTPUT RATINGS 50 HZ / 400 V
Standby Power220 kVA
176 KW
Prime Power200 kVA
160 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model P086TI
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 8,07
Bore / Stroke (mm) 111 / 139
Cycle 4
Compression Ratio 16,4. :1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 46
Lubrication Oil Capacity (lt) 15,5
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 199
Fuel Consumption (lt/h)100% 43,1
50% 21,1
ALTERNATOR
Manufacturer MECC ALTE
Origin ITALY
Model ECO 38 2SN/4
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1220x3400x1940 2175 380
OPEN SET 1150x2690x1620 1800 380
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-M220 DIESEL GENERATOR SET / 50Hz
81
www.grandvoltage.roDOOSAN – MECCALTE
OUTPUT RATINGS 50 HZ / 400 V
Standby Power275 kVA
220 KW
Prime Power250 kVA
200 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model P126TI
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 11,05
Bore / Stroke (mm) 123 / 155
Cycle 4
Compression Ratio 17.1 :1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 52
Lubrication Oil Capacity (lt) 23
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 272
Fuel Consumption (lt/h)100% 53,3
50% 27,5
ALTERNATOR
Manufacturer MECC ALTE
Origin ITALY
Model ECO 38-1LN
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1360x3960x2100 2950 470
OPEN SET 1300x3020x1600 2265 450
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-M275 DIESEL GENERATOR SET / 50Hz
82
www.grandvoltage.roDOOSAN – MECCALTE
OUTPUT RATINGS 50 HZ / 400 V
Standby Power330 kVA
264 KW
Prime Power300 kVA
240 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model P126TI-II
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 11,05
Bore / Stroke (mm) 123 / 155
Cycle 4
Compression Ratio 17.1 :1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 52
Lubrication Oil Capacity (lt) 23
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 294
Fuel Consumption (lt/h)100% 63,1
50% 31,3
ALTERNATOR
Manufacturer MECC ALTE
Origin ITALY
Model ECO 38-2LN/4
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,8
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1360x3960x2100 3065 470
OPEN SET 1300x2950x1588 2375 450
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-M330 DIESEL GENERATOR SET / 50Hz
83
www.grandvoltage.roDOOSAN – MECCALTE
OUTPUT RATINGS 50 HZ / 400 V
Standby Power410 kVA
328 KW
Prime Power375 kVA
300 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model P158LE-1
No of Cylinder / Configuration 8 / V TYPE
Displacement (lt) 14,60
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 68,5
Lubrication Oil Capacity (lt) 21
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 362
Fuel Consumption (lt/h)100% 78,7
50% 40
ALTERNATOR
Manufacturer MECC ALTE
Origin ITALY
Model ECO 40-1S/4
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x4460x2480 4024 700
OPEN SET 1550x3030x1994 3030 700
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-M410 DIESEL GENERATOR SET / 50Hz
84
www.grandvoltage.roDOOSAN – MECCALTE
OUTPUT RATINGS 50 HZ / 400 V
Standby Power485 kVA
388 KW
Prime Power425 kVA
340 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model P158LE
No of Cylinder / Configuration 8 / V TYPE
Displacement (lt) 14,60
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0 :1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 68,5
Lubrication Oil Capacity (lt) 21
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 414
Fuel Consumption (lt/h)100% 89,3
50% 43,9
ALTERNATOR
Manufacturer MECC ALTE
Origin ITALY
Model ECO 40-2S/4
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x4460x2480 4150 700
OPEN SET 1550x3110x1994 3130 700
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-M490 DIESEL GENERATOR SET / 50Hz
85
www.grandvoltage.roDOOSAN – MECCALTE
OUTPUT RATINGS 50 HZ / 400 V
Standby Power510 kVA
408 KW
Prime Power460 kVA
368 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model DP158LC
No of Cylinder / Configuration 8 / V TYPE
Displacement (lt) 14,618
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 90
Lubrication Oil Capacity (lt) 22
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 449
Fuel Consumption (lt/h)100% 99,6
50% 48,9
ALTERNATOR
Manufacturer MECC ALTE
Origin ITALY
Model ECO 40-3S/4
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x4460x2480 4100 700
OPEN SET 1550x3110x1994 3080 700
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G510 DIESEL GENERATOR SET / 50Hz
86
www.grandvoltage.roDOOSAN – MECCALTE
OUTPUT RATINGS 50 HZ / 400 V
Standby Power580 kVA
464 KW
Prime Power525 kVA
420 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model DP158LD
No of Cylinder / Configuration 8 / V TYPE
Displacement (lt) 14,61
Bore / Stroke (mm) 128 / 142
Cycle 4
Compression Ratio 15.0:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 90
Lubrication Oil Capacity (lt) 22
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 510
Fuel Consumption (lt/h)100% 115,1
50% 55,1
ALTERNATOR
Manufacturer MECC ALTE
Origin ITALY
Model ECO 40-1L/4
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x4460x2480 4200 850
OPEN SET 1550x3110x1990 3030 850
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G580 DIESEL GENERATOR SET / 50Hz
87
www.grandvoltage.roDOOSAN – MECCALTE
OUTPUT RATINGS 50 HZ / 400 V
Standby Power630 kVA
504 KW
Prime Power575 kVA
460 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model DP180LA
No of Cylinder / Configuration 10 / V TYPE
Displacement (lt) 18,273
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 112,2
Lubrication Oil Capacity (lt) 34
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 552
Fuel Consumption (lt/h)100% 123,6
50% 64,8
ALTERNATOR
Manufacturer MECC ALTE
Origin ITALY
Model ECO 40-1,5L/4
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,8
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x4810x2620 4835 850
OPEN SET 1550x3260x2060 3720 850
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G630 DIESEL GENERATOR SET / 50Hz
88
www.grandvoltage.roDOOSAN – MECCALTE
OUTPUT RATINGS 50 HZ / 400 V
Standby Power710 kVA
568 KW
Prime Power640 kVA
512 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model DP180LB
No of Cylinder / Configuration 10 / V TYPE
Displacement (lt) 18,273
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 112
Lubrication Oil Capacity (lt) 34
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 612
Fuel Consumption (lt/h)100% 136,4
50% 71,2
ALTERNATOR
Manufacturer MECC ALTE
Origin ITALY
Model ECO 40-2L/4
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,8
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x4810x2620 4940 850
OPEN SET 1550x3360x2060 4000 850
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G710 DIESEL GENERATOR SET / 50Hz
89
www.grandvoltage.roDOOSAN – MECCALTE
OUTPUT RATINGS 50 HZ / 400 V
Standby Power750 kVA
600 KW
Prime Power680 kVA
544 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model DP222LB
No of Cylinder / Configuration 12 / V TYPE
Displacement (lt) 21,93
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 134,8
Lubrication Oil Capacity (lt) 40
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 664
Fuel Consumption (lt/h)100% 147
50% 73
ALTERNATOR
Manufacturer MECC ALTE
Origin ITALY
Model ECO 40-2L/4
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x5300x2660 5400 1000
OPEN SET 1550x3494x2301 4190 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G750 DIESEL GENERATOR SET / 50Hz
90
www.grandvoltage.roDOOSAN – MECCALTE
OUTPUT RATINGS 50 HZ / 400 V
Standby Power825 kVA
660 KW
Prime Power750 kVA
600 KW
ENGINE (ESP -STAND-BY)
Manufacturer DOOSAN
Origin SOUTH KOREA
Model DP222LC
No of Cylinder / Configuration 12 / V TYPE
Displacement (lt) 21,93
Bore / Stroke (mm) 128 / 142
Cycle 4 1
Compression Ratio 5.0:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 134,8
Lubrication Oil Capacity (lt) 40
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 723
Fuel Consumption (lt/h)100% 161
50% 79,3
ALTERNATOR
Manufacturer MECC ALTE
Origin ITALY
Model ECO 40-VL/4
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1610x5300x2660 5535 1000
OPEN SET 1550x3630x2301 4320 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVDO-G825 DIESEL GENERATOR SET / 50Hz
91
Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code
CodeOrder Code
CanopiedSTAND-BY POWER
PRIME POWER
OPEN CANOPIED OPEN CANOPIED
GVR-T20 20 kVA 18 kVA 650x1400x1300 900x2200x1500 400 460 GV31464939 GV31464955
GVR-T25 25 kVA 22 kVA 650x1400x1300 900x2200x1500 450 750 GV31464940 GV31464956
GVR-T40 40 kVA 36 kVA 920x1700x1200 920x2100x1350 650 960 GV31464941 GV31464957
GVR-T50 50 kVA 45 kVA 950x1700x1450 950x2440x1620 850 1150 GV31464942 GV31464958
GVR-T55 55 kVA 50 kVA 950x1700x1450 950x2250x1600 850 1150 GV31464943 GV31464959
GVR-T75 75 kVA 68 kVA 950x1700x1450 950x2440x1620 950 1250 GV31464944 GV31464960
GVR-T90 90 kVA 81 kVA 950x1900x1500 950x2450x1650 1120 1470 GV31464945 GV31464961
GVR-T110 110 kVA 100 kVA 1100x2200x1700 1100x3000x1800 1450 1970 GV31464946 GV31464962
GVR-T125 125 kVA 113 kVA 1100x2200x1700 1100x3000x1800 1520 2040 GV31464947 GV31464963
GVR-T150 150 kVA 136 kVA 1100x2200x1700 1100x3000x1800 1680 2220 GV31464948 GV31464964
GVR-T175 175 kVA 158 kVA 1100x2200x1700 1100x2980x1860 1500 1850 GV31464949 GV31464965
GVR-T220 220 kVA 200 kVA 1100x2500x1700 1100x3400x1960 1700 2200 GV31464950 GV31464966
GVR-T306 306 kVA 275 kVA 1250x3000x1800 1250x3980x2060 2500 2850 GV31464951 GV31464967
GVR-T330 330 kVA 296 kVA 1250x3000x1800 1250x3980x2060 2600 3050 GV31464952 GV31464968
92
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power20 kVA
16 KW
Prime Power18 kVA
14 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R485
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 2,156
Bore / Stroke (mm) 80 / 95
Cycle 4
Compression Ratio 18.00 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 16
Lubrication Oil Capacity (lt) 8
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 13
Fuel Consumption (lt/h)100% 4,19
50% 2,72
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-20
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %86
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 900x2200x1500 460 120
OPEN SET 650x1400x1300 400 120
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T20 DIESEL GENERATOR SET / 50Hz
93
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power25 kVA
20 KW
Prime Power22 kVA
17,5 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R490
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 2,545
Bore / Stroke (mm) 95 / 100
Cycle 4
Compression Ratio 18.00 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 16
Lubrication Oil Capacity (lt) 8
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 21
Fuel Consumption (lt/h)100% 5,20
50% 3,38
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-25
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %86
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 900x2200x1500 750 120
OPEN SET 650x1400x1300 450 120
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T25 DIESEL GENERATOR SET / 50Hz
94
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power40 kVA
32 KW
Prime Power36 kVA
28,8 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R4100D
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 3,93
Bore / Stroke (mm) 100 / 125
Cycle 4
Compression Ratio 19.00 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 18
Lubrication Oil Capacity (lt) 12
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 33
Fuel Consumption (lt/h)100% 7,90
50% 5,14
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-40
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %88
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 950x2100x1350 960 200
OPEN SET 950x1800x1400 740 200
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T40 DIESEL GENERATOR SET / 50Hz
95
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power50 kVA
40 KW
Prime Power45 kVA
36 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R4100ZD
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 3,93
Bore / Stroke (mm) 100 / 125
Cycle 4
Compression Ratio 17.00 :1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 18
Lubrication Oil Capacity (lt) 12
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 42
Fuel Consumption (lt/h)100% 9,88
50% 6,42
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-50
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,8
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 950x2440x1620 1050 200
OPEN SET 950x1800x1400 820 200
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T50 DIESEL GENERATOR SET / 50Hz
96
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power55 kVA
44 KW
Prime Power50 kVA
40 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R4105D
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,33
Bore / Stroke (mm) 105 / 125
Cycle 4
Compression Ratio 17.00 :1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 21
Lubrication Oil Capacity (lt) 14
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 48
Fuel Consumption (lt/h)100% 10,87
50% 7,06
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-55
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,8
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 950x2440x1620 1230 200
OPEN SET 950x1800x1400 910 200
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T55 DIESEL GENERATOR SET / 50Hz
97
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power75 kVA
60 KW
Prime Power68 kVA
54 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R4105ZD
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,33
Bore / Stroke (mm) 105 / 125
Cycle 4
Compression Ratio 16.00 :1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 21
Lubrication Oil Capacity (lt) 14
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 56
Fuel Consumption (lt/h)100% 14,82
50% 9,63
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-75
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %91
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 950x2440x1620 1290 200
OPEN SET 950x1800x1500 950 200
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T75 DIESEL GENERATOR SET / 50Hz
98
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power90 kVA
72 KW
Prime Power81 kVA
64 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R4105IZLD
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,5
Bore / Stroke (mm) 105 / 130
Cycle 4
Compression Ratio 16.00 :1
Aspiration Turbocharged
Governor Type Mechanic
Cooling System Water
Coolant Capacity (lt) 24
Lubrication Oil Capacity (lt) 14
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 66
Fuel Consumption (lt/h)100% 17,78
50% 11,56
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-90
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %91
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 980x2750x1650 1390 240
OPEN SET 950x1900x1500 1120 240
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T90 DIESEL GENERATOR SET / 50Hz
99
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power110 kVA
88 KW
Prime Power100 kVA
80 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R6105AZLD
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,49
Bore / Stroke (mm) 105 / 125
Cycle 4
Compression Ratio 16.00 :1
Aspiration Turbocharged
Governor Type Mechanic
Cooling System Water
Coolant Capacity (lt) 23
Lubrication Oil Capacity (lt) 18
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 96,8
Fuel Consumption (lt/h)100% 21.2
50% 13,5
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-110
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,8
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1100x2800x1860 1715 340
OPEN SET 1100x2200x1700 1400 340
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T110 DIESEL GENERATOR SET / 50Hz
100
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power125 kVA
100 KW
Prime Power113 kVA
90 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R6105AZLD
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,75
Bore / Stroke (mm) 105 / 130
Cycle 4
Compression Ratio 16.00 :1
Aspiration Turbocharged
Governor Type Mechanic
Cooling System Water
Coolant Capacity (lt) 27
Lubrication Oil Capacity (lt) 18
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 121
Fuel Consumption (lt/h)100% 23,31
50% 15,15
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-135
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,8
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1100x2980x1860 1750 340
OPEN SET 1100x2200x1700 1400 340
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T125 DIESEL GENERATOR SET / 50Hz
101
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power150 kVA
120 KW
Prime Power136 kVA
108 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R6105AZLD
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,75
Bore / Stroke (mm) 105 / 130
Cycle 4
Compression Ratio 16.00 :1
Aspiration Turbocharged
Governor Type Mechanic
Cooling System Water
Coolant Capacity (lt) 27
Lubrication Oil Capacity (lt) 18
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 121
Fuel Consumption (lt/h) 100% 27,97
50% 18,18
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-150
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1100x2980x1860 1780 340
OPEN SET 1100x2200x1700 1450 340
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T150 DIESEL GENERATOR SET / 50Hz
102
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power175 kVA
140 KW
Prime Power158 kVA
126 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R6105IZLD
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 7,01
Bore / Stroke (mm) 105 / 135
Cycle 4
Compression Ratio 16.00 :1
Aspiration Turbocharged
Governor Type Mechanic
Cooling System Water
Coolant Capacity (lt) 27
Lubrication Oil Capacity (lt) 19
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 145,2
Fuel Consumption (lt/h)100% 30,76
50% 20
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-175
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1100x3200x1860 1825 340
OPEN SET 1100x2200x1700 1500 340
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T175 DIESEL GENERATOR SET / 50Hz
103
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power220 kVA
176 KW
Prime Power200 kVA
160 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R6113AZLD
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 7,52
Bore / Stroke (mm) 113 / 125
Cycle 4
Compression Ratio 16.00 :1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 35
Lubrication Oil Capacity (lt) 22
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 175
Fuel Consumption (lt/h)100% 41,02
50% 26,66
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-220
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,8
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1100x3400x1960 2200 400
OPEN SET 1100x2500x1700 1700 400
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T220 DIESEL GENERATOR SET / 50Hz
104
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power306 kVA
245 KW
Prime Power275 kVA
220 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R6126ZLD4
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 9,7
Bore / Stroke (mm) 126 / 130
Cycle 4
Compression Ratio 17.00 :1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 50
Lubrication Oil Capacity (lt) 19
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 235
Fuel Consumption (lt/h)100% 54,44
50% 35,38
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-330
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1250x3980x2060 2950 500
OPEN SET 1250x3000x1800 2500 500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T306 DIESEL GENERATOR SET / 50Hz
105
www.grandvoltage.roRICARDO T – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power330 kVA
264 KW
Prime Power296 kVA
237 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model R6126ZLD5
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 9,7
Bore / Stroke (mm) 126 / 130
Cycle 4
Compression Ratio 17.00 :1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 50
Lubrication Oil Capacity (lt) 19
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 269,5
Fuel Consumption (lt/h)100% 58,71
50% 38,16
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-330
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1250x3980x2060 3050 500
OPEN SET 1250x3000x1800 2600 500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-T330 DIESEL GENERATOR SET / 50Hz
106
Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code
OpenOrder Code
CanopiedSTAND-BY POWER
PRIME POWER
OPEN CANOPIED OPEN CANOPIED
GVV-G110 110 kVA 100 kVA 1100x2200x1700 1100x3000x1800 1550 2050 GV31464969 GV31464984
GVV-G145 145 kVA 130 kVA 1094x3200x1600 1260x3350x1920 1535 1995 GV31464970 GV31464985
GVV-G165 165 kVA 150 kVA 1110x3200x1920 1260x3350x1910 2150 2950 GV31464971 GV31464986
GVV-G200 200 kVA 180 kVA 1094x2570x1765 1110x3950x2170 2400 3150 GV31464972 GV31464987
GVV-G220 220 kVA 200 kVA 1094x2570x1765 1110x3950x2170 2550 3330 GV31464973 GV31464988
GVV-G275 275 kVA 250 kVA 1094x2570x1765 1110x3950x2170 2700 3450 GV31464974 GV31464989
GVV-G330 330 kVA 300 kVA 1260x3200x1920 1285x4450x2120 2920 3595 GV31464975 GV31464990
GVV-G385 385 kVA 326 kVA 1260x3200x1920 1285x4450x2120 3010 3720 GV31464976 GV31464991
GVV-G414 414 kVA 378 kVA 1260x3200x1920 1285x4450x2120 2915 3625 GV31464977 GV31464992
GVV-G440 440 kVA 400 kVA 1260x3200x1920 1285x4450x2120 3115 3825 GV31464978 GV31464993
GVV-G500 500 kVA 455 kVA 1370x3500x2180 1400x4810x2390 3640 4640 GV31464980 GV31464995
GVV-G550 550 kVA 500 kVA 1370x3500x2180 1400x4810x2390 3685 4645 GV31464981 GV31464996
GVV-G650 650 kVA 590 kVA 1670x3500x2235 1700x4820x2600 4219 5326 GV31464982 GV31464997
GVV-G700 695 kVA 630 kVA 1670x3500x2235 1700x4820x2600 4439 5516 GV31464983 GV31464998
107
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power110 kVA
88 KW
Prime Power100 kVA
80 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TAD531GE
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,76
Bore / Stroke (mm) 108 / 130
Cycle 4
Compression Ratio 18:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 19,7
Lubrication Oil Capacity (lt) 13
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 88
Fuel Consumption (lt/h)100% 19,5
50% 9,8
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT 110
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %92
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1100x3000x1800 2050 240
OPEN SET 1100x2200x1700 1550 240
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G110 DIESEL GENERATOR SET / 50Hz
108
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power145 kVA
116 KW
Prime Power130 kVA
104 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TAD532GE EDC4
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 7,15
Bore / Stroke (mm) 108 / 130
Cycle 4
Compression Ratio 17.5:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 23,8
Lubrication Oil Capacity (lt) 21
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 112
Fuel Consumption (lt/h)100% 27,4
50% 15,1
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT 150
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %92,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1260x3350x1920 1995 240
OPEN SET 1094x3200x1600 1535 240
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G145 DIESEL GENERATOR SET / 50Hz
109
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power165 kVA
132 KW
Prime Power150 kVA
120 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TAD731GE
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 7,15
Bore / Stroke (mm) 108 / 130
Cycle 4
Compression Ratio 18:1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 23,8
Lubrication Oil Capacity (lt) 21
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 133
Fuel Consumption (lt/h)100% 33,8
50% 18,8
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-165
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1260x3350x1910 2950 340
OPEN SET 1110x3200x1920 2150 340
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G165 DIESEL GENERATOR SET / 50Hz
110
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power200 kVA
160 KW
Prime Power180 kVA
144 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TAD732GE EDC4
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 7,15
Bore / Stroke (mm) 108 / 130
Cycle 4
Compression Ratio 18: 1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 38,4
Lubrication Oil Capacity (lt) 34
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 160
Fuel Consumption (lt/h)100% 40,3
50% 22,1
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT 200
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1110x3950x2170 3150 340
OPEN SET 1094x2570x1765 2400 340
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G200 DIESEL GENERATOR SET / 50Hz
111
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power220 kVA
176 KW
Prime Power200 kVA
160 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TAD733GE EDC4
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 7,15
Bore / Stroke (mm) 108 / 130
Cycle 4
Compression Ratio 18.1: 1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 38,4
Lubrication Oil Capacity (lt) 34
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 175
Fuel Consumption (lt/h)100% 45,3
50% 24,9
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT 220
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1110x3950x2170 3330 400
OPEN SET 1094x2570x1765 2550 400
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G220 DIESEL GENERATOR SET / 50Hz
112
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power275 kVA
220 KW
Prime Power250 kVA
200 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TAD734GE
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 7,15
Bore / Stroke (mm) 108 / 130
Cycle 4
Compression Ratio 17: 1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 42
Lubrication Oil Capacity (lt) 29
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 213
Fuel Consumption (lt/h)100% 51
50% 29
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT275
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1110x3950x2170 3450 400
OPEN SET 1094x2570x1765 2700 400
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G275 DIESEL GENERATOR SET / 50Hz
113
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power330 kVA
264 KW
Prime Power300 kVA
240 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TAD1341GE
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 12,78
Bore / Stroke (mm) 131 / 158
Cycle 4
Compression Ratio 18.1: 1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 44
Lubrication Oil Capacity (lt) 36
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 271
Fuel Consumption (lt/h)100% 62,2
50% 33,7
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT 330
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1285x4450x2120 3595 500
OPEN SET 1260x3200x1920 2920 500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G330 DIESEL GENERATOR SET / 50Hz
114
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power385 kVA
308 KW
Prime Power350 kVA
280 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TAD1342GE
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 12,78
Bore / Stroke (mm) 131 / 158
Cycle 4
Compression Ratio 18.1: 1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 44
Lubrication Oil Capacity (lt) 36
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 303
Fuel Consumption (lt/h)100% 68,5
50% 35,1
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-400
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1285x4450x2120 3720 800
OPEN SET 1260x3200x1920 3010 800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G385 DIESEL GENERATOR SET / 50Hz
115
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power414 kVA
331 KW
Prime Power378 kVA
302 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TAD1343GE
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 12,78
Bore / Stroke (mm) 131 / 158
Cycle 4
Compression Ratio 18.1: 1
Aspiration Turbocharged
Governor Type Electromecanic
Cooling System Water
Coolant Capacity (lt) 44
Lubrication Oil Capacity (lt) 36
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 325
Fuel Consumption (lt/h)100% 80,1
50% 43,4
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT 430
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1285x4450x2120 3625 800
OPEN SET 1260x3200x1920 2915 800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G414 DIESEL GENERATOR SET / 50Hz
116
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power440 kVA
352 KW
Prime Power400 kVA
320 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TAD1344GE
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 12,78
Bore / Stroke (mm) 131 / 158
Cycle 4
Compression Ratio 18.1: 1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 44
Lubrication Oil Capacity (lt) 36
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 354
Fuel Consumption (lt/h)100% 81,3
50% 44,1
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT 450
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1285x4450x2120 3825 800
OPEN SET 1260x3200x192 3115 800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G440 DIESEL GENERATOR SET / 50Hz
117
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power500 kVA
400 KW
Prime Power455 kVA
364 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TAD1345GE
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 12,78
Bore / Stroke (mm) 131 / 158
Cycle 4
Compression Ratio 18.1: 1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 60
Lubrication Oil Capacity (lt) 48
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 388
Fuel Consumption (lt/h)100% 91,8
50% 49,8
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT 500
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %95
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1400x4810x2390 4640 800
OPEN SET 1370x3500x2180 3640 800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G500 DIESEL GENERATOR SET / 50Hz
118
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power550 kVA
440 KW
Prime Power500 kVA
400 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TAD1641GE
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 16,12
Bore / Stroke (mm) 144 / 165
Cycle 4
Compression Ratio 16.5: 1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 60
Lubrication Oil Capacity (lt) 48
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 430
Fuel Consumption (lt/h)100% 101,3
50% 55,0
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT 550
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %95
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1400x4810x2390 4645 1000
OPEN SET 1370x3500x2180 3685 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G550 DIESEL GENERATOR SET / 50Hz
119
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power650 kVA
520 KW
Prime Power590 kVA
472 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TWD1642GE
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 16,12
Bore / Stroke (mm) 144 / 165
Cycle 4
Compression Ratio 16.5: 1
Aspiration Turbo Aftercooler
Governor Type Electromecanic
Cooling System Water
Coolant Capacity (lt) 95
Lubrication Oil Capacity (lt) 48
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 503
Fuel Consumption (lt/h)100% 116,3
50% 63,2
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT 660
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1700x4820x2600 5326 1500
OPEN SET 1670x3500x2235 4219 1500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G650 DIESEL GENERATOR SET / 50Hz
120
www.grandvoltage.roVOLVO – GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power700 kVA
556 KW
Prime Power630 kVA
504 KW
ENGINE (ESP -STAND-BY)
Manufacturer VOLVO
Origin SWEDEN
Model TWD1643GE
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 16,12
Bore / Stroke (mm) 144 / 165
Cycle 4
Compression Ratio 16.5: 1
Aspiration Turbo Aftercooler
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 95
Lubrication Oil Capacity (lt) 48
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 536
Fuel Consumption (lt/h)100% 126,2
50% 68,6
ALTERNATOR
Manufacturer GENTECH
Origin TR
Model GNT 700
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %95,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1700x4820x2600 5516 1500
OPEN SET 1670x3500x2235 4439 1500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVV-G700 DIESEL GENERATOR SET / 50Hz
121
Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code
OpenOrder Code
CanopiedSTAND-BY POWER
PRIME POWER
OPEN CANOPIED OPEN CANOPIED
GVD40 40 kVA 36 kVA 1000x2400x1385 1000x2900x1710 825 1105 GV31465025 GV31465047
GVD52 52 kVA 47 kVA 1000x2400x1385 1000x2900x1710 920 1195 GV31465026 GV31465048
GVD60 60 kVA 55 kVA 1000x2400x1385 1000x2900x1710 920 1195 GV31465027 GV31465049
GVD70 70 kVA 64 kVA 1000x2400x1480 1000x2900x1710 1060 1340 GV31465028 GV31465050
GVD110 110 kVA 100 kVA 1000x2400x1480 1000x2900x1710 1410 1130 GV31465030 GV31465052
GVD130 130 kVA 120 kVA 1050x3100x1700 1050x3580x2025 1400 1770 GV31465031 GV31465053
GVD150 150 kVA 136 kVA 1050x3100x1700 1050x3580x2025 1400 1770 GV31465032 GV31465054
GVD167 167 kVA 152 kVA 1050x3100x1700 1050x3580x2025 1610 1980 GV31465033 GV31465055
GVD180 180 kVA 164 kVA 1050x3100x1700 1050x3580x2025 1610 1980 GV31465034 GV31465056
GVD200 200 kVA 182 kVA 1050x2500x1710 1050x3580x2025 1620 1890 GV31465035 GV31465057
GVD215 215 kVA 196 kVA 1050x2500x1710 1090x3380x2000 1620 1890 GV31465036 GV31465058
GVD235 235 kVA 214 kVA 1050x3100x1700 1050x3580x2025 1790 2160 GV31465037 GV31465059
GVD290 290 kVA 263 kVA 1400x3000x2226 1400x3300x2550 2440 2940 GV31465038 GV31465060
GVD360 360 kVA 325 kVA 1600x3000x2650 1600x3600x2090 2600 3050 GV31465039 GV31465061
GVD400 400 kVA 357 kVA 1600x3000x2650 1600x3600x2550 2700 3340 GV31465040 GV31465062
GVD460 460 kVA 414 kVA 1600x3000x2650 1600x3600x2550 2750 3460 GV31465041 GV31465063
GVD550 550 kVA 500 kVA 1600x3500x2680 1600x4000x2660 3285 3980 GV31465042 GV31465064
GVD615 615 kVA 555 kVA 1600x3500x2680 1600x4000x2665 3420 4080 GV31465043 GV31465065
GVD640 640 kVA 580 kVA 1600x3500x2680 1600x4000x2665 3490 4150 GV31465044 GV31465066
GVD675 675 kVA 614 kVA 1600x3500x2680 1600x4000x2665 3540 4200 GV31465045 GV31465067
GVD700 700 kVA 363 kVA 1600x3500x2680 1600x4000x2665 3540 4250 GV31465046 GV31465068
122
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power40 kVA
32 KW
Prime Power36 kVA
28,8 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model D226B-3D
No of Cylinder / Configuration 3 / IN LINE
Displacement (lt) 3,117
Bore / Stroke (mm) 105 / 120
Cycle 4
Compression Ratio 16.40 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 12
Lubrication Oil Capacity (lt) 7,25
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 36,5
Fuel Consumption (lt/h)100% 8,12
50% 4,06
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-40
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %85,4
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1000x2900x1710 1105 170
OPEN SET 1000x2400x1385 825 170
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD40 DIESEL GENERATOR SET / 50Hz
123
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power52 kVA
41,6 KW
Prime Power47,3 kVA
37,8 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model TD226B-3D
No of Cylinder / Configuration 3 / IN LINE
Displacement (lt) 3,117
Bore / Stroke (mm) 105 / 120
Cycle 4
Compression Ratio 15.50 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 12
Lubrication Oil Capacity (lt) 7,25
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 55,2
Fuel Consumption (lt/h)100% 11,77
50% 5,89
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-55
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %87,2
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1000x2900x1710 1195 170
OPEN SET 1000x2400x1385 920 170
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD52 DIESEL GENERATOR SET / 50Hz
124
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power60 kVA
48 KW
Prime Power54,5 kVA
43,6 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model TD226B-3D
No of Cylinder / Configuration 3 / IN LINE
Displacement (lt) 3,117
Bore / Stroke (mm) 105 / 120
Cycle 4
Compression Ratio 15.50 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 17,2
Lubrication Oil Capacity (lt) 7,25
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 55,2
Fuel Consumption (lt/h)100% 13,58
50% 6,79
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-66
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %87,2
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1000x2900x1710 1195 170
OPEN SET 1000x2400x1385 920 170
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD60 DIESEL GENERATOR SET / 50Hz
125
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power70 kVA
56 KW
Prime Power63,6 kVA
50,9 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model WP4D66E200-E
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,5
Bore / Stroke (mm) 105 / 130
Cycle 4
Compression Ratio 18:1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 15,3
Lubrication Oil Capacity (lt) 10
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 66
Fuel Consumption (lt/h)100% 13,84
50% 7,50
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-75
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %88
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1000x2900x1710 1340 170
OPEN SET 1000x2400x1480 1060 170
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD70 DIESEL GENERATOR SET / 50Hz
126
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power110 kVA
88 KW
Prime Power100 kVA
80 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model WP4D66E200-D
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,5
Bore / Stroke (mm) 105 / 130
Cycle 4
Compression Ratio 18:1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 15,3
Lubrication Oil Capacity (lt) 10
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 99
Fuel Consumption (lt/h)100% 20,76
50% 11,26
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-110
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %90
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1000x2900x1710 1410 170
OPEN SET 1000x2400x1480 1130 170
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD110 DIESEL GENERATOR SET / 50Hz
127
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power130 kVA
104 KW
Prime Power120 kVA
96 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model WP4D100E200-D
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,5
Bore / Stroke (mm) 105 / 130
Cycle 4
Compression Ratio 18 :1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 16,3
Lubrication Oil Capacity (lt) 10
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 132
Fuel Consumption (lt/h)100% 25,01
50% 12,97
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-135
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1050x3580x2025 1770 350
OPEN SET 1050x3100x1700 1400 350
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD130 DIESEL GENERATOR SET / 50Hz
128
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power150 kVA
120 KW
Prime Power136 kVA
108,8 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model WP4D100E200-D
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,5
Bore / Stroke (mm) 105 / 130
Cycle 4
Compression Ratio 18 :1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 16,3
Lubrication Oil Capacity (lt) 10
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 132
Fuel Consumption (lt/h)100% 28,05
50% 14,54
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-150
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %92,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1050x3580x2025 1770 350
OPEN SET 1050x3100x1700 1400 350
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD150 DIESEL GENERATOR SET / 50Hz
129
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power167 kVA
133,6 KW
Prime Power152 kVA
121,6 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model WP6D132E200-E
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,75
Bore / Stroke (mm) 105 / 130
Cycle 4
Compression Ratio 18 :1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 26
Lubrication Oil Capacity (lt) 20
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 146
Fuel Consumption (lt/h)100% 30,5
50% 15,48
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-175
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1050x3580x2025 1980 350
OPEN SET 1050x3100x1700 1610 350
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD167 DIESEL GENERATOR SET / 50Hz
130
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power180 kVA
144 KW
Prime Power164 kVA
131,2 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model WP6D132E200-D
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,75
Bore / Stroke (mm) 105 / 130
Cycle 4
Compression Ratio 18 :1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 26
Lubrication Oil Capacity (lt) 20
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 175
Fuel Consumption (lt/h)100% 32,79
50% 16,79
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-194
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1050x3580x2025 1980 350
OPEN SET 1050x3100x1700 1610 350
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD180 DIESEL GENERATOR SET / 50Hz
131
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power200 kVA
160 KW
Prime Power182 kVA
145,6 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model WP6D132E200-D
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,75
Bore / Stroke (mm) 105 / 130
Cycle 4
Compression Ratio 18 :1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 26
Lubrication Oil Capacity (lt) 20
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 175
Fuel Consumption (lt/h)100% 36,44
50% 18,65
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-200
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,1
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1050x3580x2025 2005 350
OPEN SET 1050x3100x1700 1635 350
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD200 DIESEL GENERATOR SET / 50Hz
132
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power215 kVA
172 KW
Prime Power196 kVA
156,8 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model WP6D152E200-E
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,75
Bore / Stroke (mm) 105 / 130
Cycle 4
Compression Ratio 18 :1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 17
Lubrication Oil Capacity (lt) 9
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 186
Fuel Consumption (lt/h)100% 39,03
50% 20,31
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-220
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,2
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1090x3380x2000 1890 350
OPEN SET 1050x2500x1710 1620 350
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD215 DIESEL GENERATOR SET / 50Hz
133
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power235 kVA
188 KW
Prime Power214 kVA
171,2 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model WP6D152E200-D
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,75
Bore / Stroke (mm) 105 / 130
Cycle 4
Compression Ratio 18 :1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 26
Lubrication Oil Capacity (lt) 20
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 203
Fuel Consumption (lt/h)100% 42,71
50% 22,22
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-250
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,2
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1050x3580x2025 2160 350
OPEN SET 1050x3100x1700 1790 350
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD235 DIESEL GENERATOR SET / 50Hz
134
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power290 kVA
232 KW
Prime Power263 kVA
210 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model BF6M1015-LA-GA
No of Cylinder / Configuration 6 / V TYPE
Displacement (lt) 11,906
Bore / Stroke (mm) 132 / 145
Cycle 4
Compression Ratio 16.5: 1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 62
Lubrication Oil Capacity (lt) 36
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 231
Fuel Consumption (lt/h)100% 52,31
50% 26,78
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-330
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,2
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1400x3300x2550 2940 700
OPEN SET 1400x3000x2226 2440 700
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD290 DIESEL GENERATOR SET / 50Hz
135
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power360 kVA
288 KW
Prime Power325 kVA
260 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model BF6M1015C-LA-G2A
No of Cylinder / Configuration 6 / V TYPE
Displacement (lt) 11,906
Bore / Stroke (mm) 132 / 145
Cycle 4
Compression Ratio 16.50 :1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 62
Lubrication Oil Capacity (lt) 36
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 285
Fuel Consumption (lt/h)100% 63,92
50% 32,74
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-360
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1600x3600x2550 3215 700
OPEN SET 1600x3000x2650 2665 700
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD360 DIESEL GENERATOR SET / 50Hz
136
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power400 kVA
320 KW
Prime Power357 kVA
285 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model BF6M1015C-LA-G3A
No of Cylinder / Configuration 6 / V TYPE
Displacement (lt) 11,906
Bore / Stroke (mm) 132 / 145
Cycle 4
Compression Ratio 16.5:1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 62
Lubrication Oil Capacity (lt) 36
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 314
Fuel Consumption (lt/h)100% 70,08
50% 34,70
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-400
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1600x3600x2550 3340 700
OPEN SET 1600x3000x2650 2700 700
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD400 DIESEL GENERATOR SET / 50Hz
137
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power460 kVA
368 KW
Prime Power415 kVA
332 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model BF6M1015CP-LA-G
No of Cylinder / Configuration 6 / V TYPE
Displacement (lt) 11,906
Bore / Stroke (mm) 132 / 145
Cycle 4
Compression Ratio 16.5:1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 67
Lubrication Oil Capacity (lt) 36
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 365
Fuel Consumption (lt/h)100% 83,85
50% 41,33
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-500
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,3
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1600x3600x2550 3460 700
OPEN SET 1600x3000x2650 2750 700
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD460 DIESEL GENERATOR SET / 50Hz
138
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power550 kVA
440 KW
Prime Power500 kVA
400 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model BF8M1015C-LA-G2
No of Cylinder / Configuration 8 / V TYPE
Displacement (lt) 15,874
Bore / Stroke (mm) 132 / 145
Cycle 4
Compression Ratio 16.5 :1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 87
Lubrication Oil Capacity (lt) 48
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 440
Fuel Consumption (lt/h)100% 98,68
50% 48,86
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-550
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,4
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1600x4000x2660 3980 1000
OPEN SET 1600x3500x2680 3285 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD550 DIESEL GENERATOR SET / 50Hz
139
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power615 kVA
492 KW
Prime Power555 kVA
444 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model BF8M1015CP-LA-G2
No of Cylinder / Configuration 8 / V TYPE
Displacement (lt) 15,874
Bore / Stroke (mm) 132 / 145
Cycle 4
Compression Ratio 16.5:1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 93
Lubrication Oil Capacity (lt) 48
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 490
Fuel Consumption (lt/h)100% 117,37
50% 55,75
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-615
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,4
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1600x4000x2665 4080 1000
OPEN SET 1600x3500x2680 3420 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD615 DIESEL GENERATOR SET / 50Hz
140
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power640 kVA
512 KW
Prime Power580 kVA
464 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model BF8M1015CP-LA-G3
No of Cylinder / Configuration 8 / V TYPE
Displacement (lt) 15,874
Bore / Stroke (mm) 132 / 145
Cycle 4
Compression Ratio 16.50 :1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 93
Lubrication Oil Capacity (lt) 48
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 509
Fuel Consumption (lt/h)100% 125,24
50% 56,80
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-660
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1600x4000x2665 4150 1000
OPEN SET 1600x3500x2680 3490 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD640 DIESEL GENERATOR SET / 50Hz
141
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power675 kVA
540 KW
Prime Power614 kVA
491 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model BF8M1015CP-LA-G4
No of Cylinder / Configuration 8 / V TYPE
Displacement (lt) 15,874
Bore / Stroke (mm) 132 / 145
Cycle 4
Compression Ratio 16.50 :1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 93
Lubrication Oil Capacity (lt) 48
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 540
Fuel Consumption (lt/h) 100% 132,87
50% 60,26
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-675
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,5
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1600x4000x2665 4200 1000
OPEN SET 1600x3500x2680 3540 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD675 DIESEL GENERATOR SET / 50Hz
142
www.grandvoltage.roDEUTZ - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power700 kVA
560 KW
Prime Power636 kVA
509 KW
ENGINE (ESP -STAND-BY)
Manufacturer DEUTZ
Origin CHINA
Model BF8M1015CP-LA-G5
No of Cylinder / Configuration 8 / V TYPE
Displacement (lt) 15,874
Bore / Stroke (mm) 132 / 145
Cycle 4
Compression Ratio 16.50 :1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 93
Lubrication Oil Capacity (lt) 48
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 560
Fuel Consumption (lt/h) 100% 137,79
%50 62,49
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-700
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94,4
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1600x4000x2665 4250 1000
OPEN SET 1600x3500x2680 3540 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVD700 DIESEL GENERATOR SET / 50Hz
143
Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code
CanopiedSTAND-BY POWER
PRIME POWER
OPEN CANOPIED OPEN CANOPIED
GVR-C21 21 kVA 19,1 kVA - 950x2050x1100 - 750 GV31465079
GVR-C42 42 kVA 37,1 kVA - 950x2050x1200 - 950 GV31465081
GVR-C55 55 kVA 47,2 kVA - 950x2050x1200 - 1200 GV31465082
GVR-C70 70 kVA 63 kVA - 950x2050x1300 - 1250 GV31465083
GVR-C105 105 kVA 95 kVA - 1050x2900x1750 - 1350 GV31465084
GVR-C125 125 kVA 112 kVA - 1050x2900x1750 - 1650 GV31465085
GVR-C140 140 kVA 127 kVA - 1050x2900x1750 - 1800 GV31465086
GVR-C150 150 kVA 135 kVA - 1050x2900x1750 - 1800 GV31465087
GVR-C165 165 kVA 148,5 kVA - 1050x2900x1750 - 1900 GV31465088
GVR-C220 220 kVA 200 kVA - 1200x3250x1950 - 2000 GV31465090
GVR-C258 258 kVA 232 kVA - 1200x3400x2000 - 2500 GV31465091
GVR-C325 325 kVA 292 kVA - 1350x3800x2200 - 2600 GV31465093
144
www.grandvoltage.roRICARDO C - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power21 kVA
17 KW
Prime Power19,1 kVA
15,2 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model 4100DS
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 3,61
Bore / Stroke (mm) 95 / 115
Cycle 4
Compression Ratio 19 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 7
Lubrication Oil Capacity (lt) 15
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 26,5
Fuel Consumption (lt/h)100% 8,1
50% 4,6
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-25
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 950x2050x1100 750 61
OPEN SET - - -
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-C21 DIESEL GENERATOR SET / 50Hz
145
www.grandvoltage.roRICARDO C - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power42 kVA
33 KW
Prime Power37,1 kVA
29,7 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model 4102DS
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 3,61
Bore / Stroke (mm) 102 / 115
Cycle 4
Compression Ratio 16 :1
Aspiration Natural
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 7
Lubrication Oil Capacity (lt) 15
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 33
Fuel Consumption (lt/h)100% 9,3
50% 5,4
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-45
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 950x2050x1200 950 61
OPEN SET - - -
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-C42 DIESEL GENERATOR SET / 50Hz
146
www.grandvoltage.roRICARDO C - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power53 kVA
43 KW
Prime Power47,2 kVA
38 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model 4102ZDS
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 3,61
Bore / Stroke (mm) 102 / 115
Cycle 4
Compression Ratio 16 :1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 9
Lubrication Oil Capacity (lt) 15
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 42
Fuel Consumption (lt/h)100% 11,8
50% 6,4
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-55
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 950x2050x1200 1200 69
OPEN SET - - -
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-C53 DIESEL GENERATOR SET / 50Hz
147
www.grandvoltage.roRICARDO C - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power70 kVA
56 KW
Prime Power63 kVA
50 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model 4105ZDS
No of Cylinder / Configuration 4 / IN LINE
Displacement (lt) 4,32
Bore / Stroke (mm) 105 / 120
Cycle 4
Compression Ratio 16 :1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 9
Lubrication Oil Capacity (lt) 15
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 56
Fuel Consumption (lt/h)100% 15,7
50% 8,7
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-70
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 950x2050x1300 1250 69
OPEN SET - - -
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-C70 DIESEL GENERATOR SET / 50Hz
148
www.grandvoltage.roRICARDO C - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power105 kVA
84 KW
Prime Power95 kVA
76 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model 6105ZDS1
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 4,32
Bore / Stroke (mm) 105 / 125
Cycle 4
Compression Ratio 17 :1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 11
Lubrication Oil Capacity (lt) 26
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 84
Fuel Consumption (lt/h)100% 23,6
50% 12,9
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-105
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1050x2900x1750 1350 168
OPEN SET - - -
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-C105 DIESEL GENERATOR SET / 50Hz
149
www.grandvoltage.roRICARDO C - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power125 kVA
100 KW
Prime Power112 kVA
89 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model 6105ZLDS1
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 4,32
Bore / Stroke (mm) 105 / 125
Cycle 4
Compression Ratio 17 :1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 11
Lubrication Oil Capacity (lt) 26
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 100
Fuel Consumption (lt/h)100% 28,1
50% 15,3
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-125
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1050x2900x1750 1650 168
OPEN SET - - -
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-C125 DIESEL GENERATOR SET / 50Hz
150
www.grandvoltage.roRICARDO C - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power140 kVA
112 KW
Prime Power127 kVA
102 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model 6105ZLDS1
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,49
Bore / Stroke (mm) 105 / 125
Cycle 4
Compression Ratio 17 :1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 11
Lubrication Oil Capacity (lt) 26
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 110
Fuel Consumption (lt/h)100% 30,9
50% 16,7
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-140
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1050x2900x1750 1800 150
OPEN SET - - -
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-C140 DIESEL GENERATOR SET / 50Hz
151
www.grandvoltage.roRICARDO C - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power150 kVA
120 KW
Prime Power135 kVA
108 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model 6105AZLDS1
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,49
Bore / Stroke (mm) 105 / 125
Cycle 4
Compression Ratio 17 :1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 11
Lubrication Oil Capacity (lt) 26
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 120
Fuel Consumption (lt/h)100% 33,7
50% 18,4
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-150
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1050x2900x1750 1800 150
OPEN SET - - -
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-C150 DIESEL GENERATOR SET / 50Hz
152
www.grandvoltage.roRICARDO C - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power165 kVA
132 KW
Prime Power148,5 kVA
119 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model 6105BZLDS
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,49
Bore / Stroke (mm) 105 / 125
Cycle 4
Compression Ratio 17 :1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 11
Lubrication Oil Capacity (lt) 26
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 132
Fuel Consumption (lt/h)100% 37,1
50% 20,2
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-165
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1050x2900x1750 1900 150
OPEN SET - - -
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-C165 DIESEL GENERATOR SET / 50Hz
153
www.grandvoltage.roRICARDO C - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power220 kVA
176 KW
Prime Power200 kVA
160 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model 6110ZLDS
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,49
Bore / Stroke (mm) 105 / 125
Cycle 4
Compression Ratio 17 :1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 11
Lubrication Oil Capacity (lt) 26
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 132
Fuel Consumption (lt/h)100% 49,8
50% 27,1
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-220
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1050x2900x1750 2000 230
OPEN SET - - -
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-C220 DIESEL GENERATOR SET / 50Hz
154
www.grandvoltage.roRICARDO C - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power258 kVA
206 KW
Prime Power232 kVA
185,5 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model 6135AZLD-1
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 6,49
Bore / Stroke (mm) 126 / 130
Cycle 4
Compression Ratio 17 :1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 39
Lubrication Oil Capacity (lt) 40
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 231
Fuel Consumption (lt/h)100% 65
50% 35,2
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-260
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1200x3400x1900 2500 260
OPEN SET - - -
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-C258 DIESEL GENERATOR SET / 50Hz
155
www.grandvoltage.roRICARDO C - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power325 kVA
284 KW
Prime Power295 kVA
258 KW
ENGINE (ESP -STAND-BY)
Manufacturer RICARDO
Origin CHINA
Model 6135BZLD
No of Cylinder / Configuration 6 / IN LINE
Displacement (lt) 13,31
Bore / Stroke (mm) 135 / 150
Cycle 4
Compression Ratio 14,8 :1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 50
Lubrication Oil Capacity (lt) 19
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 231
Fuel Consumption (lt/h)100% 66,72
50% 33,3
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-325
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %1
Insulation Class H
Degree of Protection IP 22/23
Excitation System AVR, Brushless
Connection Type Y Type
Total Harmonic Content (No Load) < %3
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1350x3800x2200 3380 260
OPEN SET - - -
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVR-C325 DIESEL GENERATOR SET / 50Hz
156
Model 400 / 230 Dimensions ( WxLxH mm) WEIGHT (kg) Order Code
OpenOrder Code
CanopiedSTAND-BY POWER
PRIME POWER
OPEN CANOPIED OPEN CANOPIED
GVX250 250 227 1500x2800x1720 1500x2800x2580 2113 3100 GV314622790 GV314622807
GVX300 300 273 1500x3100x1960 1500x4200x2580 2900 4004 GV314622791 GV314622808
GVX350 350 318 1500x2800x1720 1500x2800x2580 3004 4004 GV314622792 GV314622809
GVX385 385 350 1500x2800x1720 1500x2800x2580 3004 4404 GV314622793 GV314622810
GVX425 425 386 1500x3100x1900 1500x4200x2580 3441 4406 GV314622794 GV314622811
GVX480 480 436 1500x3100x1900 1500x4200x2580 3526 4426 GV314622795 GV314622812
GVX550 550 500 1500x3500x2170 1500x4600x2810 4070 5094 GV314622796 GV314622813
GVX580 580 527 1800x4000x2100 2200x4700x2400 4800 5500 GV314622797 GV314622814
GVX630 630 573 1500x3500x2200 1500x4600x2810 4188 5095 GV314622798 GV314622815
GVX700 700 636 2100x3350x2200 2440x6600x2590 5072 7452 GV314622799 GV314622816
GVX830 830 755 2100x3350x2200 2440x6060x2590 6604 8414 GV314622800 GV314622817
GVX900 900 818 2100x3900x2200 2430x6050x2590 7264 9014 GV314622801 GV314622818
GVX950 950 864 2100x4650x2550 2430x6050x2590 9303 11053 GV314622802 GV314622819
GVX1020 1020 927 2100x4650x2550 2430x6050x2600 9303 11053 GV314622803 GV314622820
GVX1100 1100 1000 2100x4650x2550 2430x6050x2590 9608 11358 GV314622804 GV314622821
GVX1250 1250 1136 2100x4650x2550 2430x6050x2600 9608 11358 GV314622805 GV314622822
GVX1375 1375 1250 1900x4650x2550 2430x6050x2890 9722 15220 GV314622806 GV314622823
157
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power250 kVA
200 KW
Prime Power227 kVA
182 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model X6135AZLD-1
No of Cylinder / Configuration 6
Displacement (lt) 12,9
Bore / Stroke (mm) 135 / 150
Cycle 4
Compression Ratio 16.00: 1
Aspiration Turbocharged
Governor Type Mechanical
Cooling System Water
Coolant Capacity (lt) 44
Lubrication Oil Capacity (lt) 28,7
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 227
Fuel Consumption (lt/h)%100 44,45
%50 26,67
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-250
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x2800x2580 3100 400
OPEN SET 1500x2800x1720 2113 400
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX 250 DIESEL GENERATOR SET / 50Hz
158
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power300 kVA
240 KW
Prime Power273 kVA
218 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model X6135BZLD
No of Cylinder / Configuration 6
Displacement (lt) 12,9
Bore / Stroke (mm) 135 / 150
Cycle 4
Compression Ratio 16.00: 1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 70
Lubrication Oil Capacity (lt) 34,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 263
Fuel Consumption (lt/h)%100 53,34
%50 32,01
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-330
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4200x2580 4004 500
OPEN SET 1500x3100x1960 2900 500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX300 DIESEL GENERATOR SET / 50Hz
159
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power350 kVA
280 KW
Prime Power318 kVA
255 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model XG128ZLD11
No of Cylinder / Configuration 6
Displacement (lt) 12,9
Bore / Stroke (mm) 135 / 150
Cycle 4
Compression Ratio 16.00: 1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 70
Lubrication Oil Capacity (lt) 34,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 308
Fuel Consumption (lt/h)%100 62,23
%50 37,34
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-350
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x2800x2580 4004 500
OPEN SET 1500x2800x1720 3004 500
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX350 DIESEL GENERATOR SET / 50Hz
160
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power385 kVA
308 KW
Prime Power350 kVA
280 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model XG128ZLD5
No of Cylinder / Configuration 6
Displacement (lt) 12,9
Bore / Stroke (mm) 135 / 150
Cycle 4
Compression Ratio 16.00: 1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 70
Lubrication Oil Capacity (lt) 34,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 340
Fuel Consumption (lt/h)%100 62,23
%50 37,34
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-400
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %94
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x2800x2580 4404 800
OPEN SET 1500x2800x1720 3004 800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX385 DIESEL GENERATOR SET / 50Hz
161
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power425 kVA
340 KW
Prime Power386 kVA
309 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model XG128ZLD3
No of Cylinder / Configuration 6 / V TYPE
Displacement (lt) 12,9
Bore / Stroke (mm) 135 / 160
Cycle 4
Compression Ratio 16.00: 1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 70
Lubrication Oil Capacity (lt) 34,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 375
Fuel Consumption (lt/h)%100 76,06
%50 45,64
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-430
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4200x2580 4406 800
OPEN SET 1500x3100x1900 3441 800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX425 DIESEL GENERATOR SET / 50Hz
162
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power480 kVA
384 KW
Prime Power436 kVA
349 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model XG128ZLD4
No of Cylinder / Configuration 6
Displacement (lt) 12,9
Bore / Stroke (mm) 135 / 168
Cycle 4
Compression Ratio 16.00: 1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 70
Lubrication Oil Capacity (lt) 34,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 420
Fuel Consumption (lt/h)%100 85,94
%50 51,57
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-500
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4200x2580 4426 800
OPEN SET 1500x3100x1900 3526 800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX480 DIESEL GENERATOR SET / 50Hz
163
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power550 kVA
440 KW
Prime Power500 kVA
400 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model XG128ZLD6
No of Cylinder / Configuration 6
Displacement (lt) 12,9
Bore / Stroke (mm) 135 / 168
Cycle 4
Compression Ratio 16.00: 1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 70
Lubrication Oil Capacity (lt) 34,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 460
Fuel Consumption (lt/h)%100 98,78
%50 59,27
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-550
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4600x2810 5094 800
OPEN SET 1500x3500x2170 4070 800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX550 DIESEL GENERATOR SET / 50Hz
164
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power580 kVA
464 KW
Prime Power527 kVA
422 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model X12V135BZLD-1
No of Cylinder / Configuration 12
Displacement (lt) 26,6
Bore / Stroke (mm) 135 / 155
Cycle 4
Compression Ratio 16.00: 1
Aspiration Turbocharged
Governor Type Electronic
Cooling System Water
Coolant Capacity (lt) 84
Lubrication Oil Capacity (lt) 57,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 510
Fuel Consumption (lt/h)%100 103,72
%50 62,23
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-600
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2200x4700x2400 5500 800
OPEN SET 1800x4000x2100 4800 800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX580 DIESEL GENERATOR SET / 50Hz
165
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power630 kVA
504 KW
Prime Power573 kVA
458 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model X12V135BZLD-2
No of Cylinder / Configuration 12 / V TYPE
Displacement (lt) 26,6
Bore / Stroke (mm) 135 / 155
Cycle 4
Compression Ratio 16.00: 1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 84
Lubrication Oil Capacity (lt) 57,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 550
Fuel Consumption (lt/h)%100 113,6
%50 68,16
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-630
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 1500x4600x2810 5095 1000
OPEN SET 1500x3500x2200 4188 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX630 DIESEL GENERATOR SET / 50Hz
166
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power700 kVA
560 KW
Prime Power636 kVA
509 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model X12V135CZLD
No of Cylinder / Configuration 12
Displacement (lt) 26,6
Bore / Stroke (mm) 135 / 155
Cycle 4
Compression Ratio 16.00: 1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 84
Lubrication Oil Capacity (lt) 57,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 610
Fuel Consumption (lt/h)%100 124,46
%50 74,68
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-700
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2440x6600x2590 7452 1000
OPEN SET 2100x3350x2200 5072 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX700 DIESEL GENERATOR SET / 50Hz
167
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power830 kVA
664 KW
Prime Power755 kVA
604 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model X12V135CZLD-2
No of Cylinder / Configuration 12
Displacement (lt) 27
Bore / Stroke (mm) 135 / 160
Cycle 4
Compression Ratio 16.00: 1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 84
Lubrication Oil Capacity (lt) 57,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 720
Fuel Consumption (lt/h)100% 148
50% 88,90
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-850
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2440x6060x2590 6850 1000
OPEN SET 2100x3350x2200 4890 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX830 DIESEL GENERATOR SET / 50Hz
168
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power900 kVA
720 KW
Prime Power818 kVA
655 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model X12V138ZLD
No of Cylinder / Configuration 12
Displacement (lt) 28,9
Bore / Stroke (mm) 138 / 165
Cycle 4
Compression Ratio 16.00: 1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 84
Lubrication Oil Capacity (lt) 58,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 780
Fuel Consumption (lt/h)100% 161,01
50% 96,61
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-950
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2590 9014 1000
OPEN SET 2100x3900x2200 7264 1000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX900 DIESEL GENERATOR SET / 50Hz
169
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power950 kVA
760 KW
Prime Power864 kVA
691 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model X12V138CZLD
No of Cylinder / Configuration 12
Displacement (lt) 31,4
Bore / Stroke (mm) 138 / 168
Cycle 4
Compression Ratio 16.00: 1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 84
Lubrication Oil Capacity (lt) 60,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 820
Fuel Consumption (lt/h)100% 169,90
50% 101,94
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-950
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2590 11053 2000
OPEN SET 2100x4650x2550 9303 2000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX950 DIESEL GENERATOR SET / 50Hz
170
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1020 kVA
816 KW
Prime Power927 kVA
742 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model X12V138CZLD-1
No of Cylinder / Configuration 12
Displacement (lt) 31,4
Bore / Stroke (mm) 138 / 168
Cycle 4
Compression Ratio 17.5: 1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 84
Lubrication Oil Capacity (lt) 60,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 880
Fuel Consumption (lt/h)100% 182,75
50% 109,65
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-1100
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2600 11053 2000
OPEN SET 2100x4650x2550 9303 2000
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX1020 DIESEL GENERATOR SET / 50Hz
171
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1100 kVA
880 KW
Prime Power1000 kVA
800 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model X12V138CZLD-2
No of Cylinder / Configuration 12
Displacement (lt) 31,4
Bore / Stroke (mm) 138 / 168
Cycle 4
Compression Ratio 17.5: 1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 84
Lubrication Oil Capacity (lt) 60,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 960
Fuel Consumption (lt/h)100% 197,56
50% 118,54
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-1100
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2590 11358 2440
OPEN SET 2100x4650x2550 9608 2440
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX1100 DIESEL GENERATOR SET / 50Hz
172
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1250 kVA
1000 KW
Prime Power1136 kVA
909 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model XKD30H1070
No of Cylinder / Configuration 12
Displacement (lt) 31,4
Bore / Stroke (mm) 138 / 168
Cycle 4
Compression Ratio 17.5: 1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 84
Lubrication Oil Capacity (lt) 60,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1070
Fuel Consumption (lt/h)100% 243
50% 146
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-1250
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2600 11358 2600
OPEN SET 2100x4650x2550 9608 2600
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX1250 DIESEL GENERATOR SET / 50Hz
173
www.grandvoltage.roXENIC - GENTECH
OUTPUT RATINGS 50 HZ / 400 V
Standby Power1375 kVA
1100 KW
Prime Power1250 kVA
1000 KW
ENGINE (ESP -STAND-BY)
Manufacturer XENIC
Origin CHINA
Model XKD30H1160
No of Cylinder / Configuration 12
Displacement (lt) 31,4
Bore / Stroke (mm) 138 / 168
Cycle 4
Compression Ratio 17/1
Aspiration Turbocharged
Governor Type Electronical
Cooling System Water
Coolant Capacity (lt) 84
Lubrication Oil Capacity (lt) 60,4
Injection Direct
Speed / Frequency 1500 / 50 Hz
Engine Gross Power (kWm) 1160
Fuel Consumption (lt/h)100% 270,48
50% 162,288
ALTERNATOR
Manufacturer GENTECH
Origin TURKEY
Model GNT-1500
No of Phase 3
Power Factor cos 0,8
Number of Bearing SINGLE
No of Poles 4
No of Leads 12
VoltageRegulation (SteadyState) ± %0,5
Insulation Class H
Degree of Protection IP 21/23
Excitation System AVR, Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency (Hz) 50
Voltage Output (VAC) 230 / 400
Efficiency ( %) %93,9
DimensionsWxLxH
mmWeight
kgFuel Tank
ltNoisedb(A)
CANOPIED 2430x6050x2890 15220 2800
OPEN SET 1900x4650x2550 9722 2800
CONTROL UNIT
STANDART: Datakom309 OPTIONAL: Deepsea
Emergency Standby Power (ESP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Prime PowerThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3)
Sound Proof Canopy
Special design for minimizing acoustic level Galvanised steel construction further protected by polyester powdercoat paint Black finish stainless steel locks and hinges Control panel viewing window in a lockable access door Emergency stop push button (red) mounted on enclosure exterior Lifting, drag and jacking points on base frame Radiato fill via removable, flush mounted rain cap fitted with compression seal Acoustic insulation with moisture-repellent and non-flammable material
GVX1375 DIESEL GENERATOR SET / 50Hz
175
Model Phase kVA Start Type Engine HP Order Code
GVB6500E MONO 5,5 Electric Start 13 HP GV31465097
GVB7500E MONO 6,5 Electric Start 16 HP GV31465098
GVB9500E MONO 7,5 Electric Start 17,5 HP GV31465099
GVB9500E-3 THREE 9,5 Electric Start 17,5 HP GV31465100
GVD7000 MONO 7 Electric Start 10 HP GV31465101
GVD7000-3 THREE 7 Electric Start 10 HP GV31465102
GVD7000S MONO 7 Electric Start 10 HP GV31465103
GVD7000S-3 THREE 7 Electric Start 10 HP GV31465104
176
www.grandvoltage.roPORTABLE GENSETS
OUTPUT RATINGS 50 HZ / 220 V
Maximum Power 5,5 kW
Prime Power 5 kW
OUTPUT RATINGS 50 HZ / 220 V
Maximum Power 6.5 kW
Prime Power 6 kW
ENGINE
Manufacturer INTER
Origin CHINA
Model 188FE
Voltage (V) 110/240
Frequency (Hz) 50
Power Factor 1
Protection Class B
Voltage Control AVR
Output Socket 1 pc (DC 12 V)
Dimensions (mm) (LxWxH) 700*530*595
Dry Weight (Kg) 80
Noise Level dba @ 7 mt 74
Engine Type 1 cylinder, 4 P, OHV
Bore x Stroke (mm) 1-90x64
Cylinder Displacement 389
Power (rpm/min) 13 hp / 3000
Compression Rate 8,5:1
Engine Speed 3000
Starting System ELECTRIC STARTER
Fuel Type Petrol
Oil Capacity (L) 1,1
Fuel Tank Capacity (L) 25
Fuel Consumption g/kWh <374
ENGINE
Manufacturer INTER
Origin CHINA
Model 190FE
Voltage (V) 110/240
Frequency (Hz) 50
Power Factor 1
Protection Class B
Voltage Control AVR
Output Socket 1 pc (DC 12 V)
Dimensions (mm) (LxWxH) 700*530*595
Dry Weight (Kg) 83
Noise Level dba @ 7 mt 74
Engine Type 1 cylinder, 4 P, OHV
Bore x Stroke (mm) 1-90x64
Cylinder Displacement 389
Power (rpm/min) 16 hp / 3000
Compression Rate 8,5:1
Engine Speed 3000
Starting System ELECTRIC STARTER
Fuel Type Petrol
Oil Capacity (L) 1,1
Fuel Tank Capacity (L) 25
Fuel Consumption g/kWh <374
GVB6500E GASOLINE GENSET / 50Hz
GVB7500E GASOLINE GENSET / 50Hz
STANDARD FEATURES:STREAM air cooled engineAutomatic engine stop by low oil level1 unit mono phase output socketsStarting BatteriesStrong Baseframe with wheels
STANDARD FEATURES:STREAM air cooled engineAutomatic engine stop by low oil level1 unit mono phase output socketsStarting BatteriesStrong Baseframe with wheels
177
www.grandvoltage.roPORTABLE GENSETS
OUTPUT RATINGS 50 HZ / 220 V
Maximum Power 7,5 kW
Prime Power 7 kW
OUTPUT RATINGS 50 HZ / 220 V
Maximum Power 7,5 kW
Prime Power 7 kW
ENGINE
Manufacturer INTER
Origin CHINA
Model 188FE
Voltage (V) 220
Frequency (Hz) 50
Power Factor 1
Protection Class B
Voltage Control AVR
Output Socket 2 pcs
Dimensions (mm) (LxWxH) 710x540x600
Dry Weight (Kg) 90
Noise Level dba @ 7 mt 79
Engine Type 1 cylinder, 4 P
Bore x Stroke (mm) 92x66
Cylinder Displacement 678
Power (rpm/min) 17,5HP / 3600
Compression Rate 8,5:1
Engine Speed 3000
Starting System ELECTRIC STARTER
Fuel Type Petrol
Oil Capacity (L) 1,5
Fuel Tank Capacity (L) 25
Fuel Consumption g/kWh <374
ENGINE
Manufacturer INTER
Origin CHINA
Model 188FE
Voltage (V) 220
Frequency (Hz) 50
Power Factor 1
Protection Class B
Voltage Control AVR
Output Socket 2 pcs
Dimensions (mm) (LxWxH) 710x540x600
Dry Weight (Kg) 90
Noise Level dba @ 7 mt 79
Engine Type 1 cylinder, 4 P
Bore x Stroke (mm) 92x66
Cylinder Displacement 678
Power (rpm/min) 17,5HP / 3600
Compression Rate 8,5:1
Engine Speed 3000
Starting System ELECTRIC STARTER
Fuel Type Petrol
Oil Capacity (L) 1,5
Fuel Tank Capacity (L) 25
Fuel Consumption g/kWh <374
GVB9500E GASOLINE GENSET / 50Hz
GVB9500E-3 GASOLINE GENSET / 50Hz
STANDARD FEATURES:STREAM air cooled engineAutomatic engine stop by low oil level2 unit mono phase output socketsStarting BatteriesStrong Baseframe with wheels
STANDARD FEATURES:STREAM air cooled engineAutomatic engine stop by low oil level2 unit three phase output socketsStarting BatteriesStrong Baseframe with wheels
178
www.grandvoltage.roPORTABLE GENSETS
OUTPUT RATINGS 50 HZ / 220 V
Maximum Power 7 kW
Prime Power 6,5 kW
OUTPUT RATINGS 50 HZ / 220 V
Maximum Power 7 kW
Prime Power 6,5 kW
ENGINE
Model 188FAE
Voltage (V) 220
Frequency (Hz) 50
Power Factor 1
Protection Class B
Voltage Control AVR
Output Socket 1 pcs (AC)
Dimensions (mm) (LxWxH) 915x547x742
Dry Weight (Kg) 170
Noise Level dba @ 7 mt 72
Engine Type 1 cylinder, 4 P, OHV
Bore x Stroke (mm) 86X70
Cylinder Displacement 418
Power (rpm/min) 10 HP / 3600
Compression Rate 8,5:1
Engine Speed 3000
Starting System ELECTRIC STARTER
Fuel Type Diesel
Oil Capacity (L) 1,7
Fuel Tank Capacity (L) 16
Fuel Consumption g/kWh <280
ENGINE
Model 188FAE
Voltage (V) 220
Frequency (Hz) 50
Power Factor 1
Protection Class B
Voltage Control AVR
Output Socket 1 pcs (AC)
Dimensions (mm) (LxWxH) 915x547x742
Dry Weight (Kg) 170
Noise Level dba @ 7 mt 72
Engine Type 1 cylinder, 4 P, OHV
Bore x Stroke (mm) 86X70
Cylinder Displacement 418
Power (rpm/min) 10 HP / 3600
Compression Rate 8,5:1
Engine Speed 3000
Starting System ELECTRIC STARTER
Fuel Type Diesel
Oil Capacity (L) 1,7
Fuel Tank Capacity (L) 16
Fuel Consumption g/kWh <280
GVD7000 DIESEL GENSET / 50Hz
GVD7000-3 DIESEL GENSET / 50Hz
STANDARD FEATURES:Open TypeAir cooled engineAutomatic engine stop by low oil level1 unit mono phase output socketsStarting BatteriesStrong Baseframe with wheels
STANDARD FEATURES:Open TypeAvir cooled engineAutomatic engine stop by low oil level1 unit three phase output socketsStarting BatteriesStrong Baseframe with wheels
179
www.grandvoltage.roPORTABLE GENSETS
OUTPUT RATINGS 50 HZ / 220 V
Maximum Power 7 kW
Prime Power 6,5 kW
OUTPUT RATINGS 50 HZ / 220 V
Maximum Power 7 kW
Prime Power 6,5 kW
ENGINE
Model 188FAE
Voltage (V) 110/240
Frequency (Hz) 50
Power Factor 1
Protection Class B
Voltage Control AVR
Output Socket 1 pcs (AC)
Dimensions (mm) (LxWxH) 915x547x742
Dry Weight (Kg) 170
Noise Level dba @ 7 mt 72
Engine Type 1 cylinder, 4 P
Bore x Stroke (mm) 86X70
Cylinder Displacement 418
Power (rpm/min) 10 HP / 3000
Compression Rate 8,5:1
Engine Speed 3000
Starting System ELECTRIC STARTER
Fuel Type Diesel
Oil Capacity (L) 1,7
Fuel Tank Capacity (L) 16
Fuel Consumption g/kWh <280
ENGINE
Model 188FAE
Voltage (V) 110/240
Frequency (Hz) 50
Power Factor 1
Protection Class B
Voltage Control AVR
Output Socket 1 pcs (AC)
Dimensions (mm) (LxWxH) 915x547x742
Dry Weight (Kg) 170
Noise Level dba @ 7 mt 72
Engine Type 1 cylinder, 4 P
Bore x Stroke (mm) 86X70
Cylinder Displacement 418
Power (rpm/min) 10 HP / 3000
Compression Rate 8,5:1
Engine Speed 3000
Starting System ELECTRIC STARTER
Fuel Type Diesel
Oil Capacity (L) 1,7
Fuel Tank Capacity (L) 16
Fuel Consumption g/kWh <280
GVD7000S DIESEL GENSET / 50Hz
GVD7000S-3 DIESEL GENSET / 50Hz
STANDARD FEATURES:Silent ( Canopy )Air cooled engineAutomatic engine stop by low oil level1 unit mono phase output socketsStarting BatteriesStrong Baseframe with wheels
STANDARD FEATURES:Silent ( Canopy )Air cooled engineAutomatic engine stop by low oil level1 unit three phase output socketsStarting BatteriesStrong Baseframe with wheels