<ul><li><p>DSpecialty Gases &amp; Equipment</p><p>Mixtures</p></li><li><p>1-877-PRAXAIR www.praxair.com/specialtygases</p><p>Mixtures</p><p>Mixture Order MixtureComponent Blend Analytical Grade Reference ConcentrationRange Tolerance Uncertainty</p><p> EVEnvironmentalGrades(1)</p><p>NTRM T N/A N/A 1%EPAProtocol E 2ppm-25ppm 10% 1% 25.1-49.9% 5% 1%PrimaryMaster N 1ppm-9.9ppm 10% 0.1ppm 10ppm-25ppm 10% 1% 25.1ppm-9999ppm 5% 1% 1.0%-49.9% 2% 1%or 0.02%abs*CertifiedMaster M 1ppm-25ppm 20% 5% 25.1ppm-999ppm 10% 2% 0.1%-49.9% 5% 2%DynamicBlend D 1ppm-99ppm Zero 2%Master 100ppm-49.9% Zero 1%DynamicBlend Y 1ppm-99.9ppm Zero 5%Standard 100ppm-49.9% Zero 2%</p><p> STStandardGrades</p><p>PrimaryStandard P 1ppm-9.9ppm 10% 0.1ppm 10ppm-25ppm 10% 1% 25.1ppm-999ppm 5% 1% 0.1%-49.9% 2% 1%or 0.02%abs*CertifiedStandard C 1ppm-99.9ppm 20% 5% 100ppm-999ppm 10% 2% 0.1%-49.9% 5% 2%Non-Certified U 1ppm-999ppm 20% N/AStandard 0.1%-49.9% 10%CustomStandard Z 1ppm-49.9% TBD TBD</p><p>* Whicheverissmaller.(1)AllEnvironmentalGradesareNISTtraceable.Actualranges,blendtoleranceandanalyticaluncertainty arebasedonavailableNationalInstituteofStandardsandTechnology(NIST)SRMconcentrations. Pleaseseeindividualcomponentsforspecificinformation.</p><p>Note:Forallmixtures,blendtoleranceandanalyticaluncertaintyspecificationmayvarydependingonthechemicalcharacteristicsofthecomponentandthecylindersize.Formixturesoutsideoftheseranges,pleasecontactyourlocalPraxairrepresentative.</p><p>Grade Specifications</p><p>D</p><p>1</p><p>PraxairGrades</p><p>EnvironmentalGrades NTRMNISTTraceableReference MaterialsarecertifiedbytheNational InstituteofStandardsandTechnology (NIST)andacceptedbytheEnviron- mentalProtectionAgency(EPA),as thehighestaccuracystandardscom- merciallyavailable.Thesestandards aretheregulatoryequivalenttoNISTs StandardReferenceMaterials(SRMs) andaremadeupofthesamecompon- entsandarewithintheanalyticalrange ofNISTSRMs.EPAProtocolsUsedforthecalibration andauditofContinuousEmissionMoni- tors(CEMs),PraxairEPAProtocolsare NISTtraceableandproducedinaccor- dancewiththelatestEPAspecifications foundindocument-600/R97/121 Rev.9/97.PrimaryMasterHighaccuracymix- turespreparedgravimetricallyonelectronic high-precisionbalances.Thesestandards areanalyzedandnamedagainstNIST traceablereferencematerials.Certified Master Theseroutinecali- brationmixturesarepreparedbyeither gravimetric,volumetricorpartialpressure methodsandanalyzedagainstNIST traceablereferencematerials.Dynamic-BlendMasterThesezero blendtolerancemixturesareprepared onaninstrumentbaseddynamicblending system.Batchesofcylindersfromtwo toonehundredcanbeproducedwith theidenticalconcentrations.Dynamic-BlendStandardThesemix- turesarepreparedsimilarlytotheDynamic BlendMaster.Certificationofthemixtures isbasedonprocessaccuracyandPraxair PrimaryLaboratoryStandards(PPLS).AllmastergasesareanalyzedandnamedagainstNISTtraceablematerials.</p><p>StandardGradesPrimaryStandardHighlyaccurate mixturespreparedgravimetricallyon high-precisionelectronicbalances. Thesestandardsareanalyzedagainst PraxairPrimaryLaboratoryStandards (PPLS)andnamedtoagravimetrically generatedconcentration.Certified Standard Theseroutine calibrationmixturesarepreparedbyeither gravimetric,volumetricorpartialpressure methods.Thesestandardsareanalyzed againstPraxairPrimaryLaboratory Standards(PPLS).Non-Certified Mixturesareprepared bythesamemethodsandthesamecare usedforCertifiedStandardGrades. Analysesarenotreported.CustomMixturespreparedtothe exactblendtoleranceandanalytical uncertaintyrequested.</p><p>4.75% 5%</p><p>5.10% 5.20%</p><p>5.25%</p><p>Blend Tolerance</p><p>Requested Concentration</p><p>ReportedConcentration</p><p>CertificationAccuracy</p><p>Example: Relative Absolute Value Value</p><p>BlendTolerance 5%ofminor 0.25% component</p><p>AnalyticalUncertainty 2%ofminor 0.10% component</p></li><li><p>1-877-PRAXAIR www.praxair.com/specialtygases</p><p>Mixtures</p><p>Behind The Scenes</p><p>D</p><p>2</p><p>Safe, Accurate, Consistent, Reliable... Every Time</p><p>Sophisticated communication programs and mixture blending software (worldwide databases with international access) provide the very latest in mixture technology for our customers.</p><p> Component Raw Material Allblendingsourcegasesandliquids arequalifiedtoensurethattheyare appropriateforyourapplication.We havedeterminedthroughexperience thatcertainimpuritiesaffecttheper- formanceorstabilityofthefinal mixture.</p><p> Wehavedevelopedandusedspecial proprietarypurificationtechniquesfor theremovalofcriticalimpurities.Upon requestacompleteimpurityprofileor specificimpurityanalysescanbe provided.</p><p> Cylinder Preparation Praxairutilizesaseriesofcomputer controlledheating,vacuumandpurge cyclestopreparebothaluminumand steelcylinders.</p><p> Forlowconcentrationorhighly reactivecomponentsweuseour additional,proprietarycylindertreat- mentprocesses.Withtheapplication oftheseuniquecylinderpreparation processes,weareabletoproduce accuratepartperbillionandlowpart permillionconcentrationreactivegas mixtureswithguaranteedstabilities.</p><p> Blending Systems Praxairpreparesmixturesutilizing highload,highsensitivityGravimetric Balances,MicroBalanceCapillary Injection,ComputerizedDynamic BlendingSystemsandVolumetric Manifolds.Ineverycaseweusethe methodbestsuitedtoyourapplication.</p><p> Allgravimetricbalancesarecalibrated withNISTtraceableweights.Allbalan- ces,gaugesandprocessinstruments undergospecifiedperiodicmainte- nanceandcalibration.</p><p>Mixture Homogenization Onceaparticularmixtureisprepared, mechanicalrolling,gasturbulenceor molecularagitationisusedtoensure thehomogeneityofthefinalmixture.</p><p> Analytical Instrumentation GasChromatography (GCdetectors,-TCD,FID,ECD, HID,DID,FPD,PID,NPD,RGA) Chemiluminescence FourierTransformInfrared(FTIR) AtomicAbsorption(GFAA) MassSpectroscopy(MS) FluorescenceUV ProcessInstrumentation (NDIR,O2,THC,H2O)</p><p>Reference Materials StandardReferenceMaterials (SRM) NISTTraceableReference Materials(NTRM) GasManufacturersIntermediate Standards(GMIS) PraxairPrimaryLaboratory Standards(PPLS)</p><p>Ongoing Inter-Laboratory Quality Assurance Evaluation Programs PerformedQuarterly</p><p>Praxairs North American Specialty Gas Facilities are staffed with chem-ists and engineers trained in the preparation and analytical certifica-tion of specialty gas mixtures.</p><p>A knowledgeable sales and technical support team is ready to assist you in determining and specifying all your specialty needs including: high purity gases, calibration mixtures and the correct delivery equipment.</p><p>Manufacturing And Quality Control</p><p>Producingqualitygasmixturesbeginswithpropercylinderselectionandpre-parationtoensurehighqualityanden-hancedstability.Outletsareselectedac-cordingtoCompressedGasAssociation(CGA)guidelines.</p><p>ThemanufactureandcertificationofallPraxairspecialtygasesaredocumentedinacomprehensivequalityassurancemanual.Whereappropriate,traceabilitywillbeestablishedtoPraxairPrimaryLaboratoryStandardsortoNISTTrace-ableStandards.Allprocesses,proce-dures,analyticalmethodsandreportsarecarefullydocumented,controlledandinternallyassessedbyPraxairQ.C./Q.A.Officers.</p><p>Documentation</p><p>Certification:</p><p>Certificate of Compliance (COC1)Documentthatdelineatesthataproductmeetsorexceedstheminimumpurityoranalyticalaccuracyasspecified.</p><p>Certificate of Conformance (COC2)Statementofguaranteethattheproductfromaspecificbatchconformstothecomponents,minimumpurityandmaxi-mumimpurityspecificationsaslisted.</p><p>Certificate of Analysis (COA)Adocumentthatreportstheactualanalyticaltestresultsforpureproductorforacalibrationmixture.Eithersinglecylinderorbatchanalysiscertificationisavailable.</p><p>Available Upon Request!</p><p>Ask About OurISO Certified Specialty</p><p>Gas Plants</p></li><li><p>1-877-PRAXAIR www.praxair.com/specialtygases</p><p>Mixtures</p><p>Behind The Scenes</p><p>D</p><p>3</p><p> Mixture Safety and Quality</p><p>Safety and quality considerations limit the mixtures we can offer among these are:</p><p> Fuel Oxidizer Mixtures Praxair will complete a safety review foranymixturescontainingflammable and oxidizing components. Each mixture is evaluated to ensure the flammableconcentrationiswellbelow theflammablelimits.Praxairwillde- termineifthemixturemustbemade at reduced pressure. Final mixture pressuresarebasedonBTU calculations. </p><p> Vapor Pressure Restrictions Mixtures containing low vapor pressure components are generally made at reduced pressures. </p><p> Pressure reduction helps prevent condensation of less volatile component and ensures mixture homogeneity. Computer modeling is used to generate phase envelopes for mixture evaluation and determi nation of appropriate pressures. </p><p> Whereapplicable,Praxairwill recommendlow-pressurecontainers to maximize the volume of contents. RefertopageB4fordetails.</p><p> Reactive Gas Mixtures Mixturestabilityisassessedtomake sure the requested components do not react with each other or with the cylinder. Primary consideration is given to safety and the potential by-productscreatedbyachemical </p><p> reaction.Integrityofanalyticalaccu- racyisalsoevaluated.Afeasibility review is peformed prior to mixture preparation. </p><p> Whereapplicable,Praxairwillprovide aluminum or specially treated cylinders for low concentration reactive gas mixtures.SeeSectionBfordetailson aluminum(pageB3)cylinders.</p><p> Thestabilityofcertaingasmixtures canbeaffectedbythelengthoftime theyarestored,aswellasthestorage temperature.Toensuretheintegrity ofgasmixtures,storagetimeand temperatureforsusceptiblemixtures shouldbemonitored.</p><p> Mixture Grades and Specifications</p><p>Praxair mixtures are grouped into two basic categories, environmental and standard. Please refer to the table on page D1 for complete specifications of all available grades.</p><p>Environmental Gradeshavebeen developed to meet the stringent require-mentsofspecificenvironmentalappli- cationssuchasEPAProtocols,I&amp;M(InspectionandMaintenance)emissionstandards,andmixturesrequiringNISTTraceability.Inallcases,specificationshavebeendevelopedtomeetindustrystandardsor,insomecases,tomeetregulatory requirements. </p><p>WhenEPAProtocolsarenotnecessary,butNISTtraceabilityisdesired,Praxairsmaster grades provide the highest degree ofaccuracyandconfidenceforyourmostdemandingapplications.Thesemixturesarepreparedgravimetricallyonhigh- precisions,electronicbalancesorwithstate-of-the-artdynamicblenders. </p><p>Theaccuracyfromthesemethodsgenerally exceed the accuracy of most analytical instruments. Praxair produces three grades within the Master category; Primary,Certified,andDynamic-Blend.Theminorcomponent(s)areanalyzedandcertifiedbyPraxairandaretraceable toNISTreferencematerial.</p><p>Forgeneralpurposes,Praxairsstandard gradesareavailableasPrimaryand Certified.Theseanalyzedstandardsaretypicallyusedforhighvolumeapplica-tionswheretheblendingprecisionand accuracy of the Master grade is not required. Standard grade mixtures are preparedusinggravimetric,volumetric, or partial pressure methods. As in the Mastergrades,theminorcomponent(s)areanalyzedandcertified.Theecono- micalNon-Certifiedgradeissuitablefor applications that do not require analyticalcertification.</p><p>Ifyourrequirementscallforspecifica-tionsthatfalloutsideofthosedefinedbyPraxairsvariousgrades,acustomstan-dardwillincludetheexactspecificationsyou need. </p><p>If you are uncertain about which grade to choose, Praxair technical support staff can provide recommendations based on specific applications and requirements. Call your Praxair rep-resentative or your nearest customer service location for assistance!</p><p>Contact the North America </p><p>Technical Support Center at 877-PRAXAIR for assistance!</p></li><li><p>1-877-PRAXAIR www.praxair.com/specialtygases</p><p>Mixtures</p><p>Application Page</p><p>HydrocarbonProcessingIndustry E12-20</p><p>Refining E13ASTMD-3710</p><p>Refinery Gas StandardsTrace Impurity MixturesTotal Sulfur StandardsMulticomponentMixes E14-15</p><p>MulticomponentGasBlendStandards E16-17</p><p>NaturalGas E18</p><p>GPA Gas Reference StandardHigh Helium Reference StandardDanalyzer MixtureC7+ Natural Gas MixtureSour Natural Gas MixtureExtended Natural Gas MixtureNatural Gas MixturePipeline Natural Gas MixtureHigh Ethane Gas MixturePetrochemical E19</p><p>High Purity OrganicsLPG Reference StandardsHighlyReactiveVolatileOrganicCompounds E20</p><p>(HRVOC)Standards</p><p>UltraLowSulfurDiesel(ULSD) E20</p><p>FuelandGasolineStandards</p><p>IndustrialHygiene E21-28</p><p>TransportableContainers E21-23</p><p>PureGases E24</p><p>Non-ReactiveGasMixtures E24-26</p><p>Butane, Carbon Dioxide, Carbon Monoxide,Hexane, Hydrogen, Isobutylene, Methane,Nitrous Oxide, Oxygen, Pentane, Propane,(Air or Nitrogen Balance)ReactiveGasMixtures E27-28</p><p>Ammonia, Benzene, BTEX, Chlorine,Ethylene Oxide, Hydrogen Cyanide,Hydrogen Sulfide. Nitric Oxide, Nitrogen Dioxide, Phospine, Sulfur Dioxide,(Air or Nitrogen Balance)</p><p>MixtureSelectionGuide</p><p>D</p><p>4</p><p>Praxair offers flexibility in supplying customized gas mixtures for medical, industrial and scientific applications. Praxair is committed to safely producing stable, accurate mixtures. We produce mixtures from two to 50 or more components and apply all safety and quality considerations gleaned through decades of experience in mixture production. </p><p>To simplify the ordering process, Praxair has detailed the most common and popular mixtures in Gases for Special Applications, which is the next section of this catalog. For your ordering convenience, please refer to the following summary of common mixtures offered in section E.</p><p>Application Page</p><p>AnalyticalInstrumentation E1-5</p><p>InstrumentReferenceGuide</p><p>GasChromatography E2</p><p>Thermal Conductivity Detector (TCD)Flame Ionization Detector (FID)Electron Capture Detector (ECD) Helium Ionization Detector (HID)Flame Photometric Detector (FPD)Photo Ionization Detector (PID)Mass Spectrometer (GC/MS)Discharge Ionization Detector (DID)Ultrasonic Detector (USD)OpticalSpectrometry E3</p><p>Absorption</p><p>Non-dispersive Infrared (NDIR)Dispersive Infrared (IR)Fourier Transformer Infrared (FTIR)Correlation (IFG/GFC)Atomic Absorption (AA)Nuclear Magnetic Resonance (NMR)Emission E4</p><p>Inductively Coupled Plasma (ICP)Arc or Spark EmissionChemiluminescenceFluorescence UVFluorescence X (XRF)MassSpectrometry E4</p><p>Other E5</p><p>Nuclear Counter, Hydrometer, Paramagnetic Analyzer, Carbon and Sulfur in Steel</p><p>EnvironmentalMonitoring E6-11</p><p>Product Summary E7NIST Traceable Reference Materials E8EPA Protocols E8 Environmental Mixtures E9Zero Gases E10Mobile Source Emissions Gases E11</p><p> MixtureSelectionGuideSummaryofMixturesinSectionE</p></li><li><p>1-877-PRAXAIR www.praxair.com/specialtygases</p><p>Mixtures</p><p>Mixture Selection Guide</p><p>D</p><p>5</p><p> Mixture Selection Guide Summary of Mixtures in Section E</p><p>Application Page</p><p>Metal Fabrication E31-33</p><p>LaserSupplySystems E31</p><p>LaserStar5.5 E32</p><p>LaserStar5.0 E32</p><p>LaserStarStandard E33</p><p>LumonicsLaserMark4and5 E33</p><p>LaserTechnics E33</p><p>LaserElectronics E33</p><p>Life Sciences E34-40</p><p>Cryogenic Storage E35</p><p>Biological Incubation E35</p><p>AerobicIncubationMixtures E35</p><p>AnaerobicIncubationMixtures E35</p><p>Healthcare E36-40</p><p>Medical Gases</p><p>MedicalAirUSP E36</p><p>CarbonDioxideUSP E36</p><p>HeliumUSP E37</p><p>NitrogenNF E37</p><p>NitrousOxideUSP E38</p><p>OxygenUSP E38</p><p>Medical Mixtures</p><p>GeneralMedicalMixtures E39</p><p>LungDiffusion E39</p><p>BloodGasAnalysis E39</p><p>CanadianRegisteredDrugs E40</p><p>Application Page</p><p>Food E41-E44</p><p>Extendapak Gases </p><p>Dry/DehydratedProducts E41</p><p>PreparedFoods E41</p><p>RedMeats E41</p><p>Poultry E42</p><p>Fruits E42</p><p>ProcessedMeats E43</p><p>DairyProducts E43</p><p>BakeryProducts E44</p><p>FreshVeg...</p></li></ul>