carbon counting roaf
DESCRIPTION
TRANSCRIPT
Towards a Standard for Carbon Accounting: a
view from CIBSE
Hywel DaviesCIBSE Technical Director
and Stuart Macpherson Irons Foulner Consulting Engineers
Current Standards Activity
BSI, CEN and ISO are working on standards related to carbon emissions from buildings and their component materials and systems
• BS PAS 2050 – measurement of embodied greenhouse gases in products and services
• CEN - Sustainability of construction works
• CEN – Strategic energy management forum
• ISO – sustainable construction standards
Carbon counting standards
• 4 strands of standardisation (at least)
• ISO well advanced on a general framework for environmental impact measures
• CEN developing standards in response to a mandate – possible standstill on national efforts
• BSI developing the PAS on carbon
PAS 2050• Being developed jointly by Carbon Trust,
Defra and BSI• Aims to “develop an agreed method for
measuring embodied GHG emissions which can be applied across a wide range of product and service categories …to enable companies to measure the GHG related impacts of their products and reduce them.”
• Carbon and GHG specific
Directives
• The EPBD
• Scottish Building Standards
• Energy Assessors in Scotland
Carbon Accounting?
Its not just about counting carbon, but controlling it
Thank you for listening – Any questions?
What are we really trying to standardise?
• Carbon impacts or Environmental impacts?
• Products? Systems? Whole buildings?
• Cradle to gate, or cradle to grave?
• Life cycle? When does life begin and end?
• Impact of a building? Of what goes on in it? Of how people get to it (to work on it or in it)
Comparing corporate performance on climate change – what metrics?Dr. Craig MackenzieDirector, Carbon Benchmarking Project
University of Edinburgh Business School
The scope for low cost reductions
Source: Vattenfal
Breakdown of the Tesco footprint
Add note on fridge energy?
Refrigeration
Tesco CSR Report 2007
Direct CO2e emissions
Total UK Carbon Emissions
0
500,000
1,000,000
1,500,000
2,000,000
2,500,000
Somerfield Cooperative Waitrose Marks &Spencer
Sainsburys Morrisons Asda Tesco
Ton
nes
CO
2e
No Data
Relative carbon intensity?
Carbon intensity (tonnes CO2e/£turnover)
0
20
40
60
80
100
120
Somerfield Sainsburys Marks &Spencer
Tesco Cooperative Waitrose Asda Morrisons
CO
2e/£
turn
over
NB: this slide does not give an accurate comparison of performance
No Data
Meaningful comparison?
Carbon intensity (CO2e/£tunover)
0
20
40
60
80
100
120
Somerfield Sainsburys Marks &Spencer
Tesco Cooperative Waitrose Asda Morrisons
CO
2e/£
turn
over
NB: this slide does not give an accurate comparison of performance
Food processing
business
Foodnon-food
split
Food-non-food
split
Foodnon-food
split
Use of biodiesel
Green tariffelectricity
Green tariffelectricity
Data estimated
Data incomplete
No Data
Add note on fridge energy?
Refrigeration
Tesco CSR Report 2007
An alternative strategy
% f-gas leakage pa
KWh/linear meterof refrigeration
Diesel litres/pallet delivered
Average store energy rating
% electricity from renewables weighted for additionality
Wider implications
Benchmarking needs:• Better data quality• Sharper standards• Segmental carbon reporting• Identification and reporting on normalisation factors• Avoiding carbon reductionism• Activity-specific metrics• Activity/sector-specific reporting standards
• Collaborative sector/activity projects to define the above
Westminster carbon counting conference, ICE, 24 January 2008
JOINING THINGS UP FOR BUILDINGS
Bill Bordass
the Usable Buildings Trustwww.usablebuildings.co.uk
We need to save real carbon, not virtual
carbon
The Credibility Gapfor a green building award winner
Saving energy and CO2 in a
hurry, using the multiplier effect Reduced demands standards, passive measuresx 0.5? 50 %Increased efficiency better technology, lower resistancesx 0.5? 25 %Waste avoidance better control, management, behaviour?Less 20%? (it could easily be more) 20 %Low-carbon energy supplies on and off-siteHalve the carbon content of the supplies? 10%
To get rapid and cost-effective change,we must press ALL the buttons
NOT, for example relying on a business-as-usual fix with renewables: they won’t work alone!
Use renewable supplies
AND make buildings efficient in use
Making Performance Visible
with building energy certificates
Ambitions of Europrosperresearch project 2000-04:
Display energy certs based on actual energy use. Achieved
• Transparency between expectations and outcomes.Incomplete
• Multiple performance indicators Incomplete
• We now need voluntary supporting measures
Passing on carbon + energy
BPF Landlord’s statement• Improves transparency
• Includes multiple performance indicators• Allows individual tenants to add the energy they
purchase directly and prepare Display Energy Certificates on same basis as whole buildings.
• Avoids double handling if it allows the transfer of carbon from landlord to tenant for the purpose of the Carbon Reduction Commitment.
• Interest being shown by other sectors (business centres, retail, industrial
Passing on carbon + energy BPF Landlord’s
statement
Drilling down furtherto assign realistic priorities
Drilling down even further:
actual versus predicted for lighting
Carbon Counting for Neighbourhoods and Cities
Dr Rajat GuptaDepartment of Architecture
Westminster Carbon Counting Conference
24 January 2008, London
Core methodologies used in DECoRuMMethodology used Details of methodology Outputs
Building Research Establishment Domestic Energy Model (BREDEM) –12
Industry standard to calculate energy use for different dwelling types in UK. Estimates annual energy requirement for space heating, water heating, lights & appliances and cooking Requires 95 input parameters
Annual energy use (GJ/year) Annual CO2 emissions (kg/year) Running costs (£s/year)
Standard Assessment Procedure (SAP) 2001
Government’s recommended system for home energy rating based on energy costs for space and water heating.
SAP rating (scale of 1-120) Carbon Index (scale of 1-10)
Net annual cost method Used by BRE to asses cost-
effectiveness of energy efficiency measures.
Net annual cost/tonne of CO2 saved
Underlying physically-
based energy models:
BREDEM –12 linked to SAP 2001.
Cost-benefit analysis approach
Outputs from DECoRuM Outputs Expressed as
Total annual energy use kWh/year kWh/m2/year
Energy use
Annual energy use by end use kWh/year
Total annual CO2 emissions kgCO2/year kgCO2/m2/year
CO2 emissions
Annual CO2 emissions by end use kgCO2/year
Total annual running (fuel) costs £/year Fuel costs Annual running (fuel) costs by end use £/year
SAP rating Scale of 1 to 120 Energy rating Carbon Index Scale of 1 to 10
Framework for baseline predictionsDECoRuM baseline energy model estimates energy consumption and CO2 emissions of individual dwellings as the basic component for calculation, and then aggregates these to an urban scale.
Dwelling 1
Dwelling 2
Dwelling 3
Dwelling 4
Dwelling 5
Dwelling 6
Dwelling 7
Dwelling 8
Dwelling 9
Street 3
Street 2
Street 1
District 1
District 2
Oxford case study: DECoRuM baseline energy & CO2 model
© Rajat Gupta, Oxford Brookes University, Oxford, UK.
In conclusion
Top down approaches
Are they complementary to each other?
What do we need to adopt for cities to be able to estimate baseline emissions, predict
potential emission reductions, and take action?
Bottom-up models
Highest energy users on the planet
10
20
30
40
50
2000 2010 2020 2030 2040 20501990
Car
bo
n d
ioxi
de
emis
sio
ns
(MtC
O2)
Draft London Plan targets
15%20%
25% 30%
60%
Today(+0.7° C already)
Stern indicates the London Plan targets will not be sufficient
60%
90%
New evidence?
2025
London:Where emissions come from:
21%
7%
Emissions from London
Domestic
Commercial (inc. public sector)
Industrial
Ground-basedTransport
7%
22%
38%
33%
0
10
20
30
40
50
2006 2025
Responsibility for Delivering30% CO2 Cuts by 2025
Source: LECI; GLA analysis
•GLA family (~10%) City
•Boroughs (~10%)
•National government (~30%)
•Private sector (~40%)•Target reduction (30% vs. 1990)
•Mil
lion
tonn
es o
f C
O2 p
er
annu
m
•Business as usual scenario
•Individuals (~10%)
Solar Cities: 2nd International Conference 2006
LOW CARBON WOLVERCOTE
Principles of carbon counting for buildings in use
THE KEY STEPS
The five key steps in counting the impact on the outside world are:
1 Define the boundary of the premises. Boundaries should be where they make practical sense in terms of where the energy can be counted (e.g. the area fed by the meters) and how the area is run (a tenancy, a building, a site; or even a district or a city). One may look at more than one boundary, e.g. for a university the campus, specific buildings, and individual departments; and for a rented building the whole building, and each tenancy.
2 Measure the flows of each energy supply across the defined boundary. Normally this will be annual totals by fuel, though details of load profiles could sometimes be included.
3 Define carbon dioxide factors for each energy supply, as discussed below
4 Multiply each energy flow by the appropriate carbon dioxide factor, to get the emissions associated with each fuel
5 Add them up. to get the annual total of CO2 emissions.
DIRECT EMISSIONS 34%
HOUSE ENERGY 19.5%
TRANSPORT ENERGY 14.5%
INDIRECT PRO RATA EMISSONS 51%
INDIRECT INFRASTRUCTURAL EMISSONS 15%
Carbon Dioxide Emissions will include: (Source:Robert Cohen)Probably the most ‘correct’ approach is to split the scores into four categories:- Direct and measurable- Indirect, pro-rated on the bases of purchases- Indirect, not pro-rated and attributed to the industrial sectors- Fixed infrastructure, not pro-rated and attributable to government policy.
Peter Harper, Centre for Alternative technology
DECARBONISING BUILDINGSCASE STUDY: The Sports Hall
The proposed sports halls is: - 36 x 40mx 7m high, - floor area of around 1440m2.- The currently preferred design includes:- 15 Sprung Sports Floor - Lighting should be Multi-Corso set between the badminton courts- Heating system is a Continuous Black Tube radiant heating system.- 160m2 sports storage equipment- Full height glazed screen between corridor and sports hall- Range of fixed equipment including basket ball goals, netball & badminton posts- Side walls to be green or blue to meet badminton requirements-Top 3m of the 3 external walls are designed to include Kalwall Transluscent- cladding, an insulating, diffuse, light transmitting system that eliminates glare hot spots and shadows.
Recommendations:
• High the thermal efficiency of the structure of the sports hall through the use of good levels of insulation in north, south and east walls, elimination of air-infiltration through the building envelope and robust construction.
• Optimised use of natural lighting in the sports hall so reducing the need for high levels of artificial lighting.
• Naturally ventilated sports hall, eliminating the need for mechanical cooling and provision of fresh air.
• Replacement of the proposed high level, high temperature, gas fired, air blown heating system with an under-floor, low temperature heating system powered at least in part by a ground source heat pump system and a wind turbine situated in the school grounds.
• Install a roof mounted solar hot water system to provide part of the high temperature water supply needed for the changing room facilities.
The what works palette of RENs
Source: njsolar
Wind – It works and is available on site
House height 8m
400W turbineElectricity provision: 20% of a householdHeight: 2mCost: £1500-2000
6kW turbine
Electricity provision: 3.5 houses or 20% of a primary school
Height: 9m
Cost: £15-18k
220kW turbine
Electricity provision: 85 houses or 5 primary schools
Height: 36m
Cost: £550-700k
1.5MW turbine
Electricity provision: 1200 houses or 75 primary schools
Height: 65m
Cost: £1-1.5 million
RENEWABLE ENERGY GRANTS:The Low Carbon Buildings Programme
- Stream 2B. (
www.lowcarbonbuildings.org.uk/ ).
• Solar photovoltaics 50%
• Biomass 35%
• Ground source heat pumps 35%
• Wind turbines 30%
• Solar thermal 30%
CALCULATING THE COST BENEFITS OF THE SAVINGS:
Recommendation 3: Naturally ventilate the sports hall and eliminate the need for mechanical cooling and provision of fresh air. Removal of central ventilation plant and fans.
Electricity cost savings 34 kWh/m2/a saved by removal of mechanical ventilation system. = 1440 x 34 = 48960 kWh/a
CO2 savings 21.053 tonnes annumcost savings 1440 x 34 x 5.5 = £2693 annumCost of measure removes c. -£15,000 from plant cost and adds the same for
the opening Kalwal windows at the upper level. Payback 0 years
Recommendation 4: Under floor heating with GSHP power in part with a wind turbine
Replace all air blown sports hall heating system with under-floor heating from a ground source heat pump with wind turbine giving zero energy heating for the hall.
Heating gas saved 307 kWh/m2/a = 1440 x 307 = 442080 kWh/aCO2 savings 83.995 tonnes annumcost savings 442080 x 2.7 = £11,936 annumCost of measure £100,000Payback 8.38years
Key recomendations:
Recommendations and Key Actions
Estimated Annual Savings
Estimated Cost of
Measure
Payback perio
d
Financial Savin
gs
CO2 Savin
gs Energy Savings (years)
£ tonnes kWh £
high thermal efficiency of sports hall 1,400 9.9 51,840 5,000 3.57
Optimisation of the natural day lighting of the hall 3,564 12.3 64,800 2,000 0.56
Natural ventilation of the sports hall 2,693 21 48,960 0 -
Under floor heating with GSHP and wind turbine 11,936 84 442,080 100,000 3.58
Solar hot water systems 985 6.9 36,500 35,000 35.53
TOTAL 20,578 134 644,180 142,000