Capillary electrophoresis kitsKits to meet the challenges of today with the flexibility for tomorrow
The Power of Precision
2
Quantify size and purity, either reduced or non-reduced
390953 SDS-MW Analysis Kit / A10663 IgG Purity /Heterogeneity AssayThese kits were designed for the sizing and purity determination of proteins using a replaceable, gel matrix sieve. The gel is formulated to provide a sieve ranging from 10 to 220 kDa. The preparation typically involves heating a specified concentration of sample in the presence of an alkylating or reducing agent and SDS. The analyte is then separated by size using high-resolution capillary gel electrophoresis. This assay can detect impurities as low as 0.1% with UV detection or 0.01% with LIF detection.
Reduced and non-reduced NIST mAb ran reduced in <15 minutes and non-reduced in <18 minutes.
390953 SDS-MW Analysis Kit Reduced IgG
A10663 IgG Purity/Heterogeneity AssayNon-Reduced IgG
390953 Kit includes:
• Bare-fused Silica Capillary (3)
• SDS Gel Separation Buffer
• SDS Sample Buffer
• Protein Sizing Standard
• Internal Standard, 10 kDa protein
• Acidic Wash Solution, 0.1 N HCl
• Basic Wash Solution, 0.1 N NaOH
A10663 Kit includes:
• Bare-fused Silica Capillary (3)• SDS Gel Separation Buffer• SDS Sample Buffer• IgG Standard• Internal Standard, 10 kDa protein• Acidic Wash Solution, 0.1 N HCl• Basic Wash Solution, 0.1 N NaOH
For more information, visit: sciex.com/products/consumables
0.0065 –
0.0060 –
0.0055 –
0.0050 –
0.0045 –
0.0040 –
0.0035 –
0.0030 –
0.0025 –
0.0020 –
0.0015 –
0.0010 –
0.0005 –
8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5 14.0 8 9 10 11 12 13 14 15 16 17 18 19 20
AU
Minutes
Reduced IgG0.007 –
0.006 –
0.005 –
0.004 –
0.003 –
0.002 –
0.001 –
0.000 –
AU
Minutes
Non-Reduced IgG
Aggregates
0.0065 –
0.0060 –
0.0055 –
0.0050 –
0.0045 –
0.0040 –
0.0035 –
0.0030 –
0.0025 –
0.0020 –
0.0015 –
0.0010 –
0.0005 –
8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5 14.0 8 9 10 11 12 13 14 15 16 17 18 19 20
AU
Minutes
Reduced IgG0.007 –
0.006 –
0.005 –
0.004 –
0.003 –
0.002 –
0.001 –
0.000 –
AUMinutes
Non-Reduced IgG
Aggregates
3
Two times faster than HILIC with less sample prepB94499 Fast Glycan Labeling and Analysis KitThis kit was designed to rapidly label and separate released N-Glycans from glycoproteins. This method utilizes 8-aminopyrene-1,3,6-trisulfonic acid (APTS) followed by the effective removal of the excess dye using a magnetic bead based cleanup. The labeled glycans are then separated by high resolution capillary electrophoresis with laser induced fluorescence detection using the HR-NCHO separation matrix. Immediate glycan identification is determined based on their normalized electrophoretic mobility referenced against pre-determined Glucose Units (GU) values using appropriate bracketing standards.
Kit includes:
• M1 Mix• D1 Mix• D2 Mix• D3 Mix• D4 mix• L5 Mix• L6 Mix
• GU Ladder • IST (Internal Standard)• BST (Bracketing Standard Mixture)• HR-NCHO Separation Gel• Magnetic Separator • Pre-Assembled Cartridge
Adalimumab separated and identified 10 glycan species in <5 minutes
Enbrel® separated and identified 10 glycan species in <5 minutes
For more information, visit: sciex.com/products/consumables
2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 4.2
110 –
100 –
90 –
80 –
70 –
60 –
50 –
40 –
30 –
20 –
10 –
0 –
Rela
tive
Fluo
resc
ence
Uni
t
Migration Time (min)2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00
110 –
100 –
90 –
80 –
70 –
60 –
50 –
40 –
30 –
20 –
10 –
0 –
Rela
tive
Fluo
resc
ence
Uni
t
Migration Time (min)
DP2
FA1 A2 M
5FA
2A3
FA1G
1FA
3FA
2(6)
G1FA
2(3)
G1
FA2G
2
DP15 FA
2[6]G
1S1
FA2[3
]G1S
1A2
FA3
M5
DP2
DP3
A2G2
S2
A2G2
S1
FA2G
2S2
A2G1
S1
M6
FA2B
A2[3]
G1FA
2[6]G
1FA
2[3]G
1A2
G2 FA2G
2
DP15
2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 4.2
110 –
100 –
90 –
80 –
70 –
60 –
50 –
40 –
30 –
20 –
10 –
0 –
Rela
tive
Fluo
resc
ence
Uni
t
Migration Time (min)2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00
110 –
100 –
90 –
80 –
70 –
60 –
50 –
40 –
30 –
20 –
10 –
0 –
Rela
tive
Fluo
resc
ence
Uni
t
Migration Time (min)
DP2
FA1 A2 M
5FA
2A3
FA1G
1FA
3FA
2(6)
G1FA
2(3)
G1
FA2G
2
DP15 FA
2[6]G
1S1
FA2[3
]G1S
1A2
FA3
M5
DP2
DP3
A2G2
S2
A2G2
S1
FA2G
2S2
A2G1
S1
M6
FA2B
A2[3]
G1FA
2[6]G
1FA
2[3]G
1A2
G2 FA2G
2
DP15
4
Charge heterogeneity analysis in as little as 5 MinutesC44790 CZE Rapid Charge Variant Analysis KitCharge variant analysis has never been easier. In under 5 minutes of separation time, the CZE (Capillary Zone Electrophoresis) Rapid Charge Variant Analysis Kit can resolve a native state molecule’s charge variants with little-to-no method development and provide higher resolution than icIEF or ion exchange chromatography. This kit provides all of the necessary reagents to analyze a molecule’s charge variants based on its mobility. This method provides a fast, powerful separation used to quantify charge variants with a buffer that serves as both a separation matrix and dynamic coating for a bare fused silica capillary. In addition, no sample dilution buffer is required; simply dilute the sample in water and you are ready for your separation.
Kit includes:
• CZE Rapid Charge Variant Separation Buffer • Acid Wash/Regenerating Solution • CE Grade Water (H2O)• Protein Test Mix
For more information, visit: sciex.com/products/consumables
Trastuzumab charge heterogeneity profile separated utilizing the CZE Rapid Charge Variant Analysis Kit.
Minutes2.0 2.6 3.2 3.8 4.4 5.0
AU
0.060
0.055
0.045
0.035
0.015
0.000
5
Highest pI resolution availableA80976 Advanced cIEF Starter KitCapillary Isoelectric Focusing (cIEF) is a powerful technique that allows quantitative, experimental analysis of a protein’s isoelectric focusing point (pI) and charge variants. In cIEF, a mixture of sample and ampholyte is introduced into a capillary and subjected to a high voltage, creating a pH gradient through which analytes migrate to their respective pI. The PA 800 Plus system automates the process to successfully achieve high precision and quantitative separations. Use of optimized universal methods and synthetic pI markers attains the highest levels of precision (down to 0.03 pI units) in pI calculation and direct isoform quantification with online UV detection.
Kit includes:
• Neutral Capillary• cIEF Gel• pI Peptide Marker Kit (pI Marker 4.1, 5.5, 7.0, 9.5, and 10.0)
pl exp pl exp pl expPeak Mean Std Dev %RSDpl 7.0 6.957 0.008 0.115
pl 6.7 6.741 0.007 0.103
IgG a 6.473 0.007 0.114
IgG b 6.381 0.007 0.115
IgG c 6.308 0.007 0.117
IgG d 6.232 0.009 0.152
pl 5.5 5.492 0.009 0.158
CIEX cIEF separation method delivering high accuracy of pI markers coupled with extremely robust peak pI identifications of mouse IgG1k.
For more information, visit: sciex.com/products/consumables
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
0.08 –
0.07 –
0.06 –
0.05 –
0.04 –
0.03 –
0.02 –
0.01 –
0.00 –
AU
Minutes
7.0 6.7
5.5
IgG
6
Highly sensitive and effective DNA, RNA and plasmid analysis 477480 ssDNA 100R Kit / 477410 dsDNA 1000 Kit
477480 ssDNA 100R Kit
477410 dsDNA 1000 Kit
477480 Kit includes:
• DNA Capillary (2)• ssDNA 100R Gel• ssDNA 100 Test Mix• Tris-Borate Buffer• 7 M Urea• pd(A) 40-60 Test Mix
477410 Kit includes:
• DNA Capillary (2)• dsDNA 1000 Gel (3)• dsDNA 1000 Text Mix (2)• Orange G Reference Marker
Use either UV or enhanced fluorescence detection with LIF for single base resolution of DNA. SCIEX offers both ssDNA analysis of individual bases or dsDNA analysis of base pairs. These kits are ideal for plasmid and oligonucleotide analysis as well as nucleic acid integrity. They include a coated capillary, replaceable gel, test mix, and internal standard guaranteed to perform at least 100 runs.
For more information, visit: sciex.com/products/consumables
Separation of virus and plasmid DNA utilizing SCIEX dsDNA 1000 kit (Sample peaks are in green with DNA ladder peaks in black font.)
15141312 16 17 18 19 20 21 22 23 24 25
30 –
25 –
20 –
15 –
10 –
5 –
0 –
RFU
Minutes
Inje
ctio
n M
arke
r
0.07
2 kb
0.1
kb
0.2
kb
0.3
kb
0.4
kb
0.5
kb
0.65
kb
0.85
kb
1 kb
1.5
kb
2 kb
3 kb
5 kb
6 kb
7 kb
8 kb
4 kb
10 k
b
15 k
b
2.68
5 kb
0.11
8 kb
0.19
4 kb
0.23
4 kb
0.27
1 kb
0.28
1 kb
0.31
0 kb
0.60
3 kb
0.87
2 kb
1.07
8 kb
1.35
3 kb
7
0 2 4 6 8 10 12 14 16 18 20 22 24
0.030 –
0.025 –
0.020 –
0.015 –
0.010 –
0.005 –
0.000 –
AU
Minutes
Develop your ideal method477445 Protein Methods Development Kit / 501310 Method Development Kit
501310 Method Development Kit501310 Kit includes:
• Neutral Capillary• Amine Capillary• Tris Buffer, pH 8• Protein test mix• Amine Regenerator Buffer• Neutral Marker• Small Molecule Test Mix• Histamine Reference Marker• Citrate/MES Buffer, pH 6
477445 Kit includes:
• Neutral Capillary• Orange G Reference Marker• Histamine Reference Marker• Citrate Buffer, pH 3• Citrate/MES Buffer, pH 6• Tricine Buffer, pH 8• Protein Test Mix
477445 Protein Methods Development Kit
Our method development kits are a great place to start your assay development. They are designed as a starting point for the development of a capillary zone electrophoresis analysis of complex molecules. The Protein Method Development Kit contains a variety of capillaries, buffers, standards, and markers to allow you to optimize a separation method for a broad spectrum of proteins by their mass/charge characteristics. Both kits enable an end user to develop a customized method that is ideal for their molecule.
For more information, visit: sciex.com/products/consumables
IgG mobilized against the Histamine reference marker with separation in <6 minutes.
Histamine IgG
8
Improved ion analysis A53537 Anion Analysis Kit / A53540 Cation Analysis Kit
A53537 Anion Analysis Kit
A53540 Cation Analysis Kit
A53540 Kit includes:
• Cation Coating A • Cation Coating B• Cation Separation Buffer• Na Conditioner• Li Conditioner• Cation Internal Standard• Cation Test Mix• Bare-fused Silica Capillary (3)• Rinse Solution
A53537 Kit includes:
• Anion Coating • Anion Separation Buffer• Na Conditioner• Anion Acid Rinse • Anion Internal Standard• Anion Organic Test Mix• Anion Inorganic Test Mix• Bare-fused Silica Capillary (3)• Rinse Solution
The anion and cation analysis kits provide the ability to separate and quantify charged and polar analytes with indirect UV detection, in as little as four minutes. The buffer system can handle dirty samples, making sample clean up unnecessary. In addition, this method utilizes a single sample preparation step and the easy-to-use bare fused silica capillary.
For more information, visit: sciex.com/products/consumables
Easily detect counter ion differences in a sample.
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0.050 –
0.045 –
0.040 –
0.035 –
0.030 –
0.025 –
0.020 –
0.015 –
0.010 –
0.005 –
0.000 –
-0.005 –
-0.010 –
-0.015 –
AU
Minutes
Bromide
ChlorideNitrate
SulfateAzide
Fluoride
Phosphate
9
Supplies and resources
Items can be ordered at www.store.sciex.com or from your local SCIEX representative.
Description Part No.Pre-Assembled Cartridge A55625Cartridge Assembly Kit 144738Universal Vials A62251Universal Vial Caps A62250200 µL Microvials (Pkg of 100) 144709nanoVials (Pkg of 100) 504346796 well plate (Pkg of 100) 609844Bare-Fused Silica Capillary, 67 cm total x 50 µm ID (3) 338451Bare-Fused Silica Capillary, 37 cm total x 20 µm ID (3) 338475Bare-Fused Silica Capillary, 67 cm total x 75 µm ID (3) 338454Bare-Fused Silica Capillary, 111 cm total x 75 µm ID (3) 360800Bare-Fused Silica Capillary, 111 cm total x 50 µm ID (3) 360801DNA Capillary 477477Neutral Capillary 477441NCHO Capillary 477601Coolant tubing, 100 cm 144717
For more information, visit: www.store.sciex.com
The SCIEX clinical diagnostic portfolio is For In Vitro Diagnostic Use. Rx Only. Product(s) not available in all countries. For information on availability, please contact your local sales representative or refer to https://sciex.com/diagnostics. All other products are For Research Use Only. Not for use in Diagnostic Procedures. Trademarks and/or registered trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners in the United States and/or certain other countries. © 2019 DH Tech. Dev. Pte. Ltd.
RUO-MKT-03-10503-A
Headquarters500 Old Connecticut PathFramingham, MA 01701 USAPhone 508-383-7700sciex.com
International SalesFor our office locations please call the divisionheadquarters or refer to our website atsciex.com/offices
Start your path to success now: sciex.com/sciexnow
SCIEX Now™ Support NetworkThe destination for all your support needs
The Power of Precision
SCIEX Now™
SCIEXUniversityTraining
LabEnhancement
Services
WorkflowSupport
Onboarding
Self HelpResources
Product& DataSecurity
Daily Workflow
Lab Growth
Lab
Ope
ratio
ns
Method D
evelopment
SCIEX UniversityBest-in-class content, personalized learning paths - delivered using the latest memory science techniques.
Workflow SupportWhatever your challenge, the SCIEX Support team is here to help you achieve your scientific goals quickly and efficiently.
Self Help ResourcesOur Knowledge Base and Community help you
move your science forward and find the answers you need from SCIEX experts as well as your peers.
Lab Enhancement ServicesSCIEX Lab Enhancement Services apply
a holistic approach to your lab to increase productivity and reduce system downtime.
Product & Data SecurityIncrease your confidence with compliance
services to help you safeguard your data, confirm data integrity, and ensure system
modifications can be traced.
OnboardingWe register you to SCIEX Now Online, enroll you to your SCIEX University learning path, and send you a welcome email.