canyon pendant stem- installation instructions€¦ · canyon pendant stem- installation...

4
C C F Screw the stems (C) onto the nipple at the ends of the fixture (F). C A B D Make sure that the power to the fixture is turned off. Slide the slip ring (A) and the canopy (B) onto the stem (C) and leave some space. Screw the junction box crossbar (D) onto the stem (C). In the case where an emergency circuit is required, the wires to the emergency circuit will be passed through a second stem. In the case where the luminaire is installed on a grid ceiling, the power cable will pass outside of the stem. POWER SIDE POWER SIDE POWER SIDE NON POWER SIDE EMERGENCY POWER SIDE NON POWER SIDE SINGLE FIXTURE G H D A B Raise the fixture and tighten the junction box crossbar (D) with screws (by others) to the junction box (G). Make wire connection with wire connectors (H). Then slide the canopy (B) and thighten the set up with the slip ring (A). Drawing of a power junction box in the ceiling POWER SIDE FOR EMERGENCY CIRCUIT FOR FIXTURE IN GRID CEILING G D B A Raise the fixture and tighten the junction box crossbar (D) with screws (by others) to the junction box (G). Then slide the canopy (B) and thighten the set up with the slip ring (A). Drawing of a non power junction box in the ceiling NON-POWER SIDE WWW.LUMENWERX.COM www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:CANYON-PENDANT-STEM-INST November 10, 2019 Page: 1 / 4 LumenWerx ULC. reserves the right to change or modify product specifications without notification PENDANT STEM- INSTALLATION INSTRUCTIONS CANYON NOTE: Wire dimming conductors as Class 1 1 4 2 5 6 3

Upload: others

Post on 23-Sep-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CANYON PENDANT STEM- INSTALLATION INSTRUCTIONS€¦ · CANYON PENDANT STEM- INSTALLATION INSTRUCTIONS TE: Wire dimming conductors as Class 1 1 4 2 5 6 3. For a continuous system,

C

C

F

Screw the stems (C) onto the nipple at the ends of the fixture (F).

C

A

B

D

Make sure that the power to the fixture is turned off. Slide the slip ring (A) and the canopy (B) onto the stem (C) and leave some space. Screw the junction box crossbar (D) onto the stem (C).

In the case where an emergency circuit is required, the wires to the emergency circuit will be passed through a second stem.

In the case where the luminaire is installed on a grid ceiling, the power cable will pass outside of the stem.

POWER SIDEPOWER SIDE

POWER SIDENON POWER SIDE EMERGENCY POWER SIDE

NON POWER SIDE

SINGLE FIXTURE

G

H D

A

B

Raise the fixture and tighten the junction box crossbar (D) with screws (by others) to the junction box (G). Make wire connection with wire connectors (H). Then slide the canopy (B) and thighten the set up with the slip ring (A).

Drawing of a power junction box in the ceiling

POWER SIDE

FOR EMERGENCY CIRCUIT FOR FIXTURE IN GRID CEILING

G

D

B

A

Raise the fixture and tighten the junction box crossbar (D) with screws (by others) to the junction box (G). Then slide the canopy (B) and thighten the set up with the slip ring (A).

Drawing of a non power junction box in the ceiling

NON-POWER SIDE

W W W . L U M E N W E R X . C O M

www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:CANYON-PENDANT-STEM-INST November 10, 2019 Page: 1 / 4

LumenWerx ULC. reserves the right to change or modify product specifications without notification

PENDANT STEM- INSTALLATION INSTRUCTIONSCANYON

NOTE: Wire dimming conductors as Class 1

1

4

2

5 6

3

Page 2: CANYON PENDANT STEM- INSTALLATION INSTRUCTIONS€¦ · CANYON PENDANT STEM- INSTALLATION INSTRUCTIONS TE: Wire dimming conductors as Class 1 1 4 2 5 6 3. For a continuous system,

For a continuous system, repeat step 1 to 3 for all mounting hardware.

CONTINUOUS SYSTEM

L

F

N

MM

Pass the wires from the first fixture inside the seconf fixture. Align the joiners (M) of the two fixtures in the run (F) and (N) and connect them.

Unscrew the side reflectors (L) on the second fixture on the power side and remove them from the fixtures. Place the side reflectors (L) in a safe place. Repeat for all fixtures in the run.

Disconnect LED molex connectors (K) by taking a pointed object and pressing on the two tabs on the top.

K

K

J

Remove dust covers (J) on the second fixture on the power side. Repeat for all fixture in the run.

I

Unscrew and remove the top cap (I). Place it in a safe place.

W W W . L U M E N W E R X . C O M

7

10

8

11

9

www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:CANYON-PENDANT-STEM-INST November 10, 2019 Page: 2 / 4

LumenWerx ULC. reserves the right to change or modify product specifications without notification

12

PENDANT STEM- INSTALLATION INSTRUCTIONSCANYON

Page 3: CANYON PENDANT STEM- INSTALLATION INSTRUCTIONS€¦ · CANYON PENDANT STEM- INSTALLATION INSTRUCTIONS TE: Wire dimming conductors as Class 1 1 4 2 5 6 3. For a continuous system,

C

C

Screw the stems (C) onto the end nipples of the two fixtures in the run and on the joiner.

G

D

AB

H

Raise the fixtures and tighten the junction box crossbars (D) with screws (by others) to the junction boxes (G). Make wire connection on the power side with wire connectors (H). Then slide the canopies (B) and thighten the sets up with the slip rings (A).

POWER SIDE NON POWER SIDE

Reconnect LED molex connectors (J) to the side reflectors (K). Reinstall the side reflectors (K).

B+

_

K

L

I

Install the top cap (P) on top of the joiners.

P

Connect wires between joining fixtures using quick connectors (P).

M

F

N

O

O

Secure the two fixtures (F) and (N) by fastening set screws (O) on the joiners (M).

W W W . L U M E N W E R X . C O M

13

16

14

17

15

www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:CANYON-PENDANT-STEM-INST November 10, 2019 Page: 3 / 4

LumenWerx ULC. reserves the right to change or modify product specifications without notification

18

PENDANT STEM- INSTALLATION INSTRUCTIONSCANYON

Page 4: CANYON PENDANT STEM- INSTALLATION INSTRUCTIONS€¦ · CANYON PENDANT STEM- INSTALLATION INSTRUCTIONS TE: Wire dimming conductors as Class 1 1 4 2 5 6 3. For a continuous system,

Reinstall dust covers (I) back in place.

J

W W W . L U M E N W E R X . C O M

19

www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:CANYON-PENDANT-STEM-INST November 10, 2019 Page: 4 / 4

LumenWerx ULC. reserves the right to change or modify product specifications without notification