California Title 24 Multi-Family Compliance Solutions 24 TITLE Can be used to comply with 2019 Part 6 Understanding the New Requirements Total Required Ventilation Rate = (.03 x sq. ft.) + (7.5 x (bedrooms + 1)) Examples: - 1,000 sq. ft., 1 BR = 45 CFM - 1,200 sq. ft., 2 BR = 59 CFM - 1,600 sq. ft., 2 BR = 71 CFM Two Compliance Options: - Balanced Ventilation System - Continuously operating exhaust or continuously operating supply allowed only if envelope leakage is 0.3 CFM at 50 Pa per square foot of dwelling unit surface area Minimum MERV 13 filter required on supply or supply side of balanced systems Let Us Help You Meet Title 24’s Multi-Family Requirements Broan’s “Best-in-Class” ventilation solutions can help customers meet Title 24 requirements two different ways. If a contractor can prove the dwelling unit leakage is 0.3 CFM at 50 pascals per square foot of envelope surface area, the use of a continuous supply or continuous exhaust option can be used. The continuous options are: 1) 2) If a dwelling has a greater unit leakage than 0.3 CFM, a balanced ventilation system will provide all the needs to meet the requirements. See options outlined on back for a balanced ventilation system. Any Broan fan under 1.0 Sone FIN-180B -180 CFM Power Cord basic supply fan FIN-180P-180 CFM Power Cord Premium Supply Fan FIN-180P-HW-180 CFM hardwired Premium Supply Fan FIN-180B-HW-180 CFM hardwired basic supply fan

Upload: others

Post on 05-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: California Title 24 Multi-Family Compliance Solutions · Title 24 requirements two different ways. If a contractor can prove the dwelling unit leakage is ≤ 0.3 CFM at 50 pascals

California Title 24Multi-Family Compliance Solutions

24TITLE Can be used

to comply with2019 Part 6

Understanding theNew Requirements

Total Required Ventilation Rate =(.03 x sq. ft.) + (7.5 x (bedrooms + 1))

Examples:- 1,000 sq. ft., 1 BR = 45 CFM- 1,200 sq. ft., 2 BR = 59 CFM- 1,600 sq. ft., 2 BR = 71 CFM

Two Compliance Options:- Balanced Ventilation System- Continuously operating exhaust or continuously operating supply allowed only if envelope leakage is ≤ 0.3 CFM at 50 Pa per square foot of dwelling unit surface area

Minimum MERV 13 filterrequired on supply or supply sideof balanced systems

Let Us Help You Meet Title 24’sMulti-Family RequirementsBroan’s “Best-in-Class” ventilation solutions can help customers meetTitle 24 requirements two different ways.

If a contractor can prove the dwelling unit leakage is ≤ 0.3 CFM at50 pascals per square foot of envelope surface area, the use ofa continuous supply or continuous exhaust option can be used.

The continuous options are:

1)

2) If a dwelling has a greater unit leakage than 0.3 CFM, a balancedventilation system will provide all the needs to meet the requirements.See options outlined on back for a balanced ventilation system.

Any Broan fan under 1.0 SoneFIN-180B-180 CFM Power Cord basic supply fanFIN-180P-180 CFM Power Cord Premium Supply FanFIN-180P-HW-180 CFM hardwired Premium Supply FanFIN-180B-HW-180 CFM hardwired basic supply fan

Page 2: California Title 24 Multi-Family Compliance Solutions · Title 24 requirements two different ways. If a contractor can prove the dwelling unit leakage is ≤ 0.3 CFM at 50 pascals

Broan - NuTone LLC | Hartford, Wisconsin 53027800-558-1711 | www.broan.com

24TITLE

Balanced Ventilation System Options

Can be usedto comply with2019 Part 6

99851068A I 11/19

Low Speed Balanced

Low Speed Balanced

ZB80 or ZB110,Low speed

set to same CFMas supply fan

ZB110H,Low speed

set to same CFMas supply fan

AE50110DC orQTXE110150DC

Fan Only

FIN-180B-HW,Continuous Speed

(30-180 CFM) Supply.Set to required CFM level.

FIN-180B-HW,Continuous Speed

(30-180 CFM) Supply.Set to required CFM level.

FIN-180B-HW,Continuous Speed

(30-180 CFM) Supply.Set to required CFM level

DT100W Duty Cycle timer forintermittent balanced solution

3 way switch in bathroom orutility closet to turn balanced

system ON / OFF

Humidity Sensing

120V Line In

120V Line In

120V Line In

BoostOn / Off rocker

Boost Mode

High SpeedBoost

ContinuouslyBalanced Ventilationwithout Humidity SensingExhaust Ventilation Fan andSupply Fan set the required CFM level

Exhaust Fan ZB80 or ZB110- 80 CFM, < 0.3 Sones- 110 CFM, < 0.3 SonesSupply Fan FIN-180B-HW- 30-180 CFM, 0.65 Sones at 130 CFMWall Controls- One 3-Way Switch- One Single Rocker

ContinuouslyBalanced Ventilationwith Humidity SensingExhaust Ventilation Fan andSupply Fan set the required CFM level

Exhaust Fan ZBH110H- 110 CFM, < 0.3 SonesSupply Fan FIN-180B-HW- 30-180 CFM, 0.65 Sones at 130 CFMWall Controls- Single Rocker Switch

IntermittentBalanced VentilationExhaust Ventilation Fan andSupply Fan set to 110 CFM to match

Exhaust Fan AE50110DC or QTXE110150DC- Many CFM and Sone OptionsSupply Fan FIN-180B-HW- 30-180 CFM, 0.65 Sones at 130 CFMWall Controls- DT100W Duty Cycle Timer