california title 24 2013 lighting and lighting controls...

15
© 2014 Eaton. All rights reserved. Date: July 29, 2014 California Title 24 2013 Lighting and Lighting Controls Only Scope: Title 24 2013 – Residential Compliance

Upload: others

Post on 11-Aug-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

© 2014 Eaton. All rights reserved.

Date: July 29, 2014

California Title 24 2013 Lighting and Lighting Controls Only Scope: Title 24 2013 – Residential Compliance

Page 2: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

2 © 2014 Eaton. All rights reserved.

Outline

• Scope of “Residential Compliance” • Key definitions • When Title 24 compliance is required • Spaces – Structure for code • Solutions for Title 24 2013 compliance

Page 3: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

3 © 2014 Eaton. All rights reserved.

Scope of “Residential Compliance”

Title 24 Occupancy Types include R-1, R-2, R-3, and R-4. CEC is clarifying the full scope that touches upon the living spaces, “dwellings”, of these types.

With additional requirements

Single Family Home Multi-Family Home High-Rise Home

Dormitory Senior Living Quarters Hotel / Motel / Guest Rooms

Page 4: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

4 © 2014 Eaton. All rights reserved.

Key definitions Certified to Title 20 Appliance Database (T20)

• Repository of products manufactures report meet the requirements of the appliance codes

• For residential, includes self-contained lighting controls and LED luminaires

Occupancy Group • Classification of that defines the compliance types of a

space • Residential Compliance only applies to a portion of

Group R and Group U (Group U, when located on Single Family lot)

Location of circuit • Critical to know how the lighting products are switched • Control switch/circuit in a space will determine the

compliance requirements • Example: When a dining room switched from the

kitchen, code requires the dining room lighting meet the kitchen code requirements.

High Efficacy • Used in Resident Compliance ONLY • Lighting products reported by manufacturers

meeting the code requirements • Requirements and reporting vary by

technology type (i.e.: LED luminaires T20, CFL luminaires using T20 CFL ballasts)

Low Efficacy • Used in Residential Compliance ONLY • Lighting products that are NOT reported by

manufactures meeting high efficacy code requirements

Self-contained Lighting Controls • Control module that requires no additional

component to be fully functional • Must be certified to Title 20 Appliance

Database to be sold in California for California use

Page 5: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

5 © 2014 Eaton. All rights reserved.

New Construction

Additions

Alterations

Modification- in-Place

Repair

When Title 24 Code compliance is required

Single Family All Other Residential

LED Module Note

Not discussed

Not discussed

New Construction

Additions

Alterations

Modification- in-Place

Repair

≥10% Luminaires

≥40 Luminaires, 1:1 Replace

Not discussed

Page 6: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

6 © 2014 Eaton. All rights reserved.

Spaces – Structure of code Kitchens

Other Rooms Outdoor – Single Family

Bathrooms

Outdoor – Multi-Family / High-Rise

Garages, Laundry Rooms and Utility Rooms

Page 7: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

7 © 2014 Eaton. All rights reserved.

Kitchens • Must not exceed 50% power • Products that are not High Efficacy, qualify

90CRI Certified to T20

Controls: • High Efficacy and Low Efficacy MUST be separately circuited • Rooms switched from kitchen are considered part of the kitchen • Controls are NOT required but recommended

Coming Soon

SLD LED EL4 LED ELG4 LED ML56 LED HU10 LED RL56 LED RL4 LED

Non-Incandescent IC/AT Housings

H457 H457R H750 H750R H724G24 H724RGU24 P3

80CRI LED / Non-T20 Ballasts

IC/AT Housings RA56 LED P3LED

806/07 Low Efficacy ML56LED HU20 LED LV/H SCN WN

H7 H7R H36/38 H36R H570 H571R

• ≥50% Power must be high efficacy • CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires • IC/AT recessed housing GU-24 & non-incandescent • Linear Fluorescent with T20 certified ballast

High Efficacy Low Efficacy

Coming Soon

Page 8: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

8 © 2014 Eaton. All rights reserved.

Bathrooms • At least 1 luminaire must be high efficacy • CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires • IC/AT recessed housing GU-24 & non-incandescent • Linear Fluorescent with T20 certified ballast

• Separate circuit from High Efficacy • Products that are not High Efficacy, qualify

Controls: • High Efficacy and Low Efficacy MUST be separately circuited • Low Efficacy controlled by T20 Vacancy Sensor

80CRI LED / Non-T20 Ballasts

ONW VNW

90CRI Certified to T20 Coming

Soon

SLD LED EL4 LED ELG4 LED ML56 LED HU10 LED RL56 LED RL4 LED

Non-Incandescent IC/AT Housings

H457 H457R H750 H750R H724G24 H724RGU24 P3

RA56 LED P3LED

806/07 Low Efficacy ML56LED HU20 LED 601 600 WN

IC/AT Housings

H7 H7R H36/38 H36R H570 H571R

High Efficacy Low Efficacy

Coming Soon

Page 9: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

9 © 2014 Eaton. All rights reserved.

Garages, Laundry, Utility Rooms • ALL luminaires must be High Efficacy • CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires • IC/AT recessed housing GU-24 & non-incandescent • Linear Fluorescent with T20 certified ballast

• Not allowed

Controls: • T20 Vacancy Sensor

ONW VAC

90CRI Certified to T20 Coming

Soon

SLD LED EL4 LED ELG4 LED ML56 LED HU10 LED RL56 LED RL4 LED

Non-Incandescent IC/AT Housings

H457 H457R H750 H750R H724G24 H724RGU24 P3

RA56 LED

H995

High Efficacy Low Efficacy

Page 10: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

10 © 2014 Eaton. All rights reserved.

Other Rooms (Not previously covered)

• Can be ALL High Efficacy and controls not required • CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires • IC/AT recessed housing GU-24 and non-incandescent • Linear Fluorescent with T20 certified ballast

• If Low Efficacy, must be controlled • Products that are not High Efficacy, qualify

Controls: • Low Efficacy MUST be separately circuited • Low Efficacy MUST be controls by a vacancy sensor OR dimmer ONW VNW CLS

80CRI LED / Non-T20 Ballasts

IC/AT Housings

806/07 Low Efficacy ML56LED HU20 LED H2522/23 SCN 240

WN H2524

H7 H7R H36/38 H36R H570 H571R

90CRI Certified to T20 Coming

Soon

Non-Incandescent IC/AT Housings

H457 H457R H750 H750R H724G24 H724RGU24 P3

RA56 LED P3LED

SLD LED EL4 LED ELG4 LED ML56 LED HU10 LED RL56 LED RL4 LED

High Efficacy Low Efficacy

Coming Soon

Page 11: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

11 © 2014 Eaton. All rights reserved.

Single Family Outdoor (Attached to any building)

High Efficacy • Can be ALL High Efficacy and controls not required • CFL luminaires with T20 ballasts, GU-24, T20 LED

luminaires, High Pressure Sodium, Pulse Start Metal Halide <150W, T20 Pulse Start Metal Halide ≥ 150W

• IC/AT recessed housing GU-24 and non-incandescent • Linear Fluorescent with T20 certified ballast

Low Efficacy • If not High Efficacy, must be controlled

Certified to T20 / Non-Incandescent IC/AT

LED, INC, CFL, and HID

Controls: • Low Efficacy manual ON/OFF does not override ON automatic actions • When Low Efficacy, T20 Motion Sensor AND T20 Photocontrol, T20 Astronomical Time Clock, or EMS

FE VT GP FSL MS MST XTOR

714 903 303

HID / CFL

W PFL23 MD FFL23

SLD LED ML56 LED RL56 LED H457 H457R H750 H750R

Page 12: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

12 © 2014 Eaton. All rights reserved.

Low-Rise Multi-Family Outdoor (Can comply with non-residential compliance instead)

• Can be ALL High Efficacy and controls not required • CFL luminaires with T20 ballasts, GU-24, T20 LED

luminaires, High Pressure Sodium, Pulse Start Metal Halide <150W, T20 Pulse Start Metal Halide ≥ 150W

• IC/AT recessed construction when used: GU-24 and non-incandescent

• Linear Fluorescent with T20 certified ballast

• If not High Efficacy, must be controlled

Certified to T20 / Non-Incandescent IC/AT

LED, INC, CFL, and HID

Controls: • Low Efficacy manual ON/OFF does not override ON automatic actions • When Low Efficacy, T20 Motion Sensor AND T20 Photocontrol, T20 Astronomical Time Clock, or EMS

FE VT GP FSL MS MST XTOR

714 903 303

HID / CFL

W PFL23 MD FFL23

High Efficacy Low Efficacy

SLD LED ML56 LED RL56 LED H457 H457R H750 H750R

Page 13: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

13 © 2014 Eaton. All rights reserved.

High-Rise Family Outdoor (Attached to the building)

High Efficacy Low Efficacy

Controls: • High-Rise, considered residential when switched from inside dwelling • Low Efficacy manual ON/OFF does not override ON automatic actions • When Low Efficacy, T20 Motion Sensor AND T20 Photocontrol, T20 Astronomical Time Clock, or EMS

Certified to T20 / Non-Incandescent IC/AT

LED, INC, CFL, and HID

FE VT GP FSL MS MST XTOR

714 903 303

HID / CFL

W PFL23 MD FFL23

• Can be ALL High Efficacy and controls not required • CFL luminaires with T20 ballasts, GU-24, T20 LED

luminaires, High Pressure Sodium, Pulse Start Metal Halide <150W, T20 Pulse Start Metal Halide ≥ 150W

• IC/AT recessed housing GU-24 and non-incandescent • Linear Fluorescent with T20 certified ballast

• If not High Efficacy, must be controlled

SLD LED ML56 LED RL56 LED H457 H457R H750 H750R

Page 14: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

14 © 2014 Eaton. All rights reserved.

References • California Title 20 Appliance Database search tool

(http://www.appliances.energy.ca.gov/Default.aspx)

• California Title 24 2013 Building Energy Efficiency Standards main website (http://www.energy.ca.gov/title24/2013standards/)

• California Title 24 2013 Residential Compliance Manual website (http://www.energy.ca.gov/title24/2013standards/residential_manual.html)

• California Title 24 2013 Residential Compliance Manual Residential Lighting document (http://www.energy.ca.gov/2013publications/CEC-400-2013-001/chapters/06_Residential_Lighting.pdf)

Page 15: California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code

15 © 2014 Eaton. All rights reserved.