calibration traceability chart - na caltechnologies · na caltechnologies co., ltd. national...

15
NA Caltechnologies Co., Ltd. 75/107 Moo 11, Klongnueng, Klonglaung, Pathumthani 12120, Thailand Tel. +66-2-529-2460 Fax. +66-2-529-2466 Email: [email protected] URL: www.nacal.co.th Calibration Traceability Chart

Upload: lamngoc

Post on 11-Oct-2018

257 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

NA Caltechnologies Co., Ltd.75/107 Moo 11, Klongnueng, Klonglaung,

Pathumthani 12120, Thailand

Tel. +66-2-529-2460

Fax. +66-2-529-2466

Email: [email protected]

URL: www.nacal.co.th

Calibration Traceability Chart

Page 2: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

NA's Highest

Standards

NA's Working

Standards

Customer's

Equipment

Remark:

Page 8 FEZ-0009-G-Form-03/V6 /01/11/16

* ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Office of the National Standardization Council of Thailand (ONSC), Thai Industrial Standards Institute, Ministry of Industry (TISI)).

01-Nov-04 Jamnong Yanyong

Traceability ChartPrepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Cal. Manager)

Date: 26-Jan-17

Scope: Electrical Calibration (1)(Voltage, Current, Power)

Voltage/Current Meters (Analog/Digital):- * DCV Meters (0~1kV)- * ACV Meters (0~1kV, 10Hz~30MHz)- * DCA Meters (0~100A)- * DCA Clamp Meter (0~1kA)- * ACA Meters (0~50A, 10Hz~100kHz)- * ACA Clamp Meter (0~1kA, 45~440Hz- * Digital Electrometer (1pA~20mA, 0~1kV)- * DC/AC Cut-off Current Meter (0~100mA, 50~60Hz)

Watt Meters/Sources (Analog/Digital):- * DCW Meters (1mW~20kW)- * ACW Meters (1mW~20kW, 45~65Hz, PF 0.3~1)- * Watt Meter With Clamp (1mW~20kW)- * Power Hi Testers (DCV, DCA, ACV, ACA, DCW, ACW)- DCW Source (1mW~20kW)- ACW Source (1mW~20kW, 10Hz-10kHz)

Voltage/Current Sources (Analog/Digital):- * DCV Calibrators/Sources (0~1kV)- * ACV Calibrators/Sources (0~1kV, 10Hz-30MHz)- * DCA Calibrators/Sources (0~200A)- * ACA Calibrators/Sources (0~50A, 10Hz-30kHz)- * DC Power Supplies (DCV, DCA)- * AC Power Supplies (ACV, ACA, Freq.)- DC/AC Cut-Off Current Source (Withstanding Testers)

Working Standard Equipment: Functions / Ranges:

- DCV Standard Cell, Fluke 732B- Multi-function Calibrator, Fluke 5700A- Multi-product Calibrator, Fluke 5520A- Multi-product Calibrator, Fluke 5500A- DC V/A Standard, Yokogawa 2560- AC V/A Standard, Yokogawa 2558- Calibrator & Source, Keithley 263- Multi-function Transfer Standard, Wavetek 4950- Digital Multimeter, HP 3458A (Opt-002)- Reference Multimeter, Fluke 8508 - Digital Multimeter, Fluke 8846A- Digital Multimeter, Agilent 34411A, 34401A- Electrometer, Keithley 617- Metal Film Resistor Set, Fluke- AC/DC Shunt, Wavetek 4953- Metal Clad Resistor Set, PCN- Standard Resistor Set, Yokogawa 27X2's- Standard Shunt, Yokogawa 2743- Standard Resistor, Advantest TR's series- DC Power Supply, Kikusui PAK10-100- Electronic Load, Kikusui PLZ's series- AC/DCA Cut-off Meter, Kikusui TOS-1200- True RMS Clamp Meter , Fluke 376

- DCV 10V, 1.018V- DCV (0~1kV), DCA (0~2.2A), ACV (0~1kV, 10Hz~1MHz), ACA (0~2.2A, 10Hz~10kHz)- DCV (0~1kV), DCA (0~20A), ACV (0~1kV, 10Hz~500kHz), ACA (0~20A, 10Hz~30kHz)- DCV (0~1kV), DCA (0~10A), ACV (0~1kV, 10Hz~500kHz), ACA (0~10A, 10Hz~10kHz)- DCV (0~1kV), DCA (0~30A)- ACV (0~1kV, 40Hz~400Hz), ACA (0~50A, 40Hz~400Hz)- DCV (0~20V), DCA (0~20mA)- DCV (0~1kV), DCA (0~1A), ACV (0~1kV, 10Hz~1MHz), ACA (0~1A, 10Hz~30kHz)- DCV (0~1kV), DCA (0~1A), ACV (0~0.7kV, 10Hz~10MHz), ACA (0~1A, 10Hz~100kHz)- DCV (0~1kV), DCA (0-20A), ACV (0-1kV, 10Hz-1MHz), ACA (0-20A, 10Hz-100kHz)- DCV (0~1kV), DCA (0~10A), ACV (0~1kV, 10Hz~500kHz), ACA (0~10A, 10Hz~30kHz)- DCV (0~1kV), DCA (0~3A), ACV (0~0.7kV, 10Hz~500kHz), ACA (0~3A, 10Hz~30kHz)- DCV (0~200V), DCA (0~20mA)- ACA (AC/DC Diff, 3µA~10mA, 10Hz~100kHz)- ACA (AC/DC Diff, 10mA~10A, 10Hz~100kHz)- DC/ACA (0~200A, DC~60Hz)- DCA (0~20A)- DCA (20~100A)- DCA (10pA~10nA)- DCA (0~100A)- DCV (0~500V), DCA (0~140A), DCW (0~1000W)- DC/ACA Cut-Off (0~100mA, DC~60Hz)- DCA (0~1000A), ACA (0-2500A, 50Hz,60Hz)

Working Standard Equipment: Functions / Ranges:

- DCV Standard Cell, Fluke 732B- Multi-function Calibrator, Fluke 5720A- Amplifier, Fluke 5725A- AC Measurement System, Fluke 5790A+WB- Digital Multimeter, Agilent 3458A (Opt-002)

- Reference Multimeter, Fluke 8508

- Standard Resistor Set, Fluke 742A's- Standard Resistor Set, IET SRX's series- Metal Film Resistor Set, Fluke- AC Shunt Set, Fluke A40's- AC Shunt Guidline 7320- Primary AC Shunt HOLT HCS-1

- DCV 10V, 1.018V- DCV (0~1kV), DCA (0-2.2A), ACV (0-1kV, 10Hz-1MHz), ACA 0-2.2A (10Hz-10kHz)- ACV (300~1kV, 40Hz-100kHz), DCA (2.2-11A), ACA (2.2-11A, 10Hz-10kHz)- ACV (2mV~1kV, 10Hz-1MHz), AC-DC Diff (2mV-1kV, 10Hz-1MHz), ACV (Wide-Band, 50Ω, 2mV-7V, 10Hz-30MHz)- DCV (0~1kV), DCA (0-1A), ACV (0-0.7kV, 10Hz-10MHz), ACA (0-1A, 10Hz-100kHz)- DCV (0~1kV), DCA (0-20A), ACV (0-1kV, 10Hz-1MHz), ACA (0-20A, 10Hz-100kHz)- DCA (0~200mA)- DCA (0A~20A)- ACA (AC/DC Diff, 3µA~10mA, 10Hz~100kHz)- ACA (AC/DC Diff, 10mA~5A, 10Hz~30kHz)- ACA (AC/DC Diff, 5A~10A, 10Hz~30kHz)- ACA (AC/DC Diff, 10A~50A, 10Hz~30kHz)

National Institute of Metrology (Thailand), NIMT

NSC-TISI-TIS 17025

Calibration No. 0289

NA Caltechnologies Co., Ltd.75/107 M. 11, Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466

Page 3: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

Accredited

Laboratories

NA's Highest

Standards

NA's Working

Standards

Customer's

Equipment

Remark:

Page 9 FEZ-0009-G-Form-03/V6 /01/11/16

* ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Office of the National Standardization Council of Thailand (ONSC), Thai Industrial Standards Institute, Ministry of Industry (TISI)).

Jamnong

Traceability Chart

01-Nov-04

Prepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Cal. Manager)

Date: 26-Jan-17

Scope: Electrical Calibration (2)(High Voltage, Resistance)

High Volt. Meters/Sources:- * DC/AC High Volt. Meters- * DC/AC High Volt. Sources- * Withstanding Volt. Testers/

Electrical Safety Testers- Electrostatic Field Meters- High Voltage Probes- High Voltage Dividers- Impulse TestersRange: DCV/ACV: 0.5kV~10kV,

50Hz~60Hz

DC Resistance Meters:- * DC Resistance Meters- * Resistance Bridge- * mΩ Testers- * MΩ Testers- * Insulation Testers- * Super MΩ Meters- Wristrap/Shoes Testers- Surface Resistance Testers Range: DCR: 0~10GΩ

DC Resistance Sources:- * DC Resistance Calibrators- * DC Resistance Sources- * DC Standard Resistors- * DC Decade Resistance Boxes- * DC Resistors

Range: DCR: 0~10GΩ

DC Electrometer/Sources:- * DC Electrometers- * Ultra High Res. Meters- * DC High Resistance Sources- * DC Giga/Tera Ohm Meters- * DC Giga/Tera Ohm Resistors- * DC Giga/Tera Ohm Decade

Boxes

Range: DCR: 1MΩ~1TΩ

AC Resistance Meters/Sources:- AC Resistance Meters (LCR Meters)- AC Low Ohm Testers- AC Ground Bond Testers- AC Resistance Sources- AC Resistors

Range: ACR: 1mΩ~100MΩ (10Hz~13MHz)

Standard Equipment:- DC/AC High Volt. Digital Meter,

Kikusui 149-10A- Electrostatic Meter, Trek 347- High Voltage Probe,

Tektronix P6015A- Withstanding Volt. Tester,Kikusui TOS5101

- Digital Multimeter,Agilent 34411A, 34401A

Range: DCV/ACV: 0.5kV~10kV,50Hz~60Hz

Standard Equipment: Functions/Ranges:

- Multi-function Calibrator, Fluke 5700A- Multi-product Calibrator, Fluke 5520A- Multi-product Calibrator, Fluke 5500A- Digital Multimeter, HP 3458A (Opt-002)- Reference Multimeter, Fluke 8508A- Digital Multimeter, Agilent 34411A, 34401A- Digital Multimeter, Fluke 8846A- Standard Resistors, Yokogawa 2792's Series- Calibrator & Source, Keithley 263- Electrometer, Keithley 617- Metal Clad Resistor Set, PCN- Decade Resistance Box Set

- DCR (0~100MΩ)- DCR (0~1GΩ)- DCR (0~330MΩ)- DCR (0~1GΩ)- DCR (0~20GΩ)- DCR (0~1GΩ)- DCR (0~1GΩ)- DCR (1m~100kΩ)- DCR (0~100GΩ)- DCR (0~100GΩ)- DCR (1mΩ~5Ω)- DCR (0~1TΩ)

Standard Equipment:- Precision LCR Meter, Agilent E4980A- LF Impedance Analyzer, HP 4192A- LCR Standard, Sun Jem 6100A- Calibration Standard, HP 16074A- Standard AC Resistor Set, Electrohm- Metal Clad Resistor Set, PCN

Range: ACR (1mΩ~100MΩ, 10Hz-13MHz)

Standard Equipment/Ranges:- High Voltage Power Amplifier,Trek 10/10B

- Multi-Product Calibrator,Fluke 5520A

Range: DCV/ACV: 0.5kV~10kV,50Hz~60Hz

Standard Equipment: Functions/Ranges:- Multi-function Calibrator, Fluke 5720A- Digital Multimeter, Agilent 3458A (Opt-002)- Reference Multimeter, Fluke 8508A- Standard Resistor Set, Fluke 742A's- Standard Resistor Set, IET SRX's series

- DCR (0~100MΩ)- DCR (0~1GΩ)- DCR (0~20GΩ)- DCR (0~10kΩ)- DCR (0~10MΩ)

Standard Equipment/Ranges:- Precision LCR Meter, Agilent E4980A- Four-Terminal Pair Resistors, HP 42030A

Range: ACR: 1mΩ~100MΩ, 10Hz~13MHz

Thai Airway International Public Co., Ltd. (TLAS Accredited No. 0003)

Agilent Technologies (Japan)(JCSS no.: 0048)

National Institute of Metrology (Thailand), NIMTCSIRO National Measurement Laboratory (NML), Australia

National Metrology Institute of Japan (NMIJ), Japan

NSC-TISI-TIS 17025

Calibration No. 0289

NA Caltechnologies Co., Ltd.75/107 M. 11, Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466

Page 4: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

Accredited

laboratories

NA's Highest

Standards

NA's Working

Standards

Customer's

Equipment

Remark:

Page 10 FEZ-0009-G-Form-03/V6 /01/11/16* ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Office of the National Standardization Council of Thailand (ONSC), Thai Industrial Standards Institute, Ministry of Industry (TISI)).

01-Nov-04 Jamnong Yanyong

Traceability ChartPrepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Cal. Manager)

Date: 26-Jan-17

Scope: Electrical Calibration (3)(Capacitances, Inductances)

Capacitance Meters:- * 2-Terminal Type LCR Meters (Capacitance)- * 4-Terminal Type LCR Meters (Capacitance)- * Digital Multimeters (Capacitance)- * Capacitance % Meters

Range: 1pF~110mF, 10Hz~13MHz

Capacitance Sources:- * 2-Terminal Type Standard Capacitors- * 4-Terminal Type Standard Capacitors- * Capacitance Calibrators/Sources- * Decade Capacitance Boxes- * Capacitors

Range: 1pF~110mF, 10Hz~13MHz

Range: ACR: 1mΩ~100MΩ (10Hz~13MHz)

Inductance Meters:- * 2-Terminal Type LCR Meters (Inductance)- * 4-Terminal Type LCR Meters (Inductance)- * Digital Multimeters (Inductance)- * Inductance Meters

Range: 100µH~1H, 100Hz~100kHz

Range: ACR: 1mΩ~100MΩ (10Hz~13MHz)

Inductance Sources:- * Standard Inductors- * Inductance Sources- * Decade Inductance Boxes- * Inductors

Range: 1µH~10H, 100Hz~100kHz

Range: ACR: 1mΩ~100MΩ (10Hz~13MHz)

Standard Equipment: Functions/Ranges:

- Precision LCR Meter, Agilent E4980A- LF Impedance Analyzer, HP 4192A- Decade Inductor, ANDO AM3301- Standard Self Inductor Set, GenRad 1482

- 10nH ~ 1kH (100Hz ~ 100kHz)- 10nH ~ 100kH (100Hz ~ 100kHz)- 1mH ~ 1H (100Hz ~ 100kHz)- 100µH~1H, (100Hz~10kHz)

Standard Equipment: Functions/Ranges:- 4-T Standard Capacitor Set, HP16380A, 16380C- Multi-product Calibrator, Fluke 5520A- Multi-product Calibrator, Fluke 5500A- Precision LCR Meter, Agilent E4980A- LF Impedance Analyzer, HP 4192A- LCR Standard, Sun Jem 6100A- Standard Capacitor Set, Shoshin- Decade Capacitor, HP 4440B- Precision Decade Capacitor General Radio 1413

- 1pF~1µF- 0.19nF~110mF- 0.33nF~1.1mF- 1pF~100mF- 1pF~100mF- 100pF~100mF- 30pF~60pF- 40pF~1.1µF- 1pF~1µF

Standard Equipment/Ranges:4-Terminal Standard Capacitor Set,HP16380A, 16380CRange: 1pF~1µF, 10Hz~13MHz

Standard Equipment/Ranges:- Precision LCR Meter, Agilent E4980A 10nH~1kH, (100Hz~100kHz)- Standard Self Inductor Set, Ando RS's Series 100µH~1H, (100Hz~10kHz)

Agilent Technologies (Japan)(JCSS no.: 0048)

National Metrology Institute of Japan (NMIJ), Japan

National Institute of Metrology (Thailand), NIMT

Standard Equipment/Ranges:- Precision LCR Meter, Agilent E4980A 1pF~100mF, (20Hz~2MHz)

NSC-TISI-TIS 17025

Calibration No. 0289

NA Caltechnologies Co., Ltd.75/107 M. 11, Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466

Page 5: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

Accredited

Laboratories

-

NA's Highest - Standards

-

NA's Working

Standards

Customer's

Equipment

Remark:

Page 11 FEZ-0009-G-Form-03/V6 /01/11/16

* ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Office of the National Standardization Council of Thailand (ONSC), Thai Industrial Standards Institute, Ministry of Industry (TISI)).

01-Nov-04 Jamnon Yanyong

22-Nov-07

Traceability ChartPrepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Cal. Manager)

Date: 26-Jan-17

Scope: Electrical Calibration (4)(Frequency, RF Power)

Frequency Meters/Sources:- * Frequency / Universal Counters- * Microwave / Time Interval Counters- * Frequency Standards / Quartz Testers- * Frequency Sources from Other Instrument- * Digital Multimeters (Frequency) / Frequency Meters- Timers / Stopwatches- Tachometers / Stroboscopes

Range: 1Hz~40GHz

RF Power Meters: RF Power Sources:

Example of Instrument (RF Measurement Function):- RF Power Meters- RF Power Sensors- Spectrum Analyzers- RF Level Meters- Modulation Analyzer- Radio Communication Analyzers- Site Masters- Network AnalyzersRange: -100dBm~44dBm, 100Hz~40GHz,

50Ω, 75Ω, 600Ω

Example of Instrument (RF Source Function):- *Signal Generators / Function Generators- *Synthesized Sweepers- Pulse Generators- RF Oscillators- Synthesized Level Generators-* Network Analyzers- RF Power Amplifier / Splitter

Range: -100dBm~44dBm, 100Hz~40GHz,50Ω, 75Ω, 600Ω

Standard Equipment: Functions/Ranges:

- Rubidium Frequency Standard, Sansei FSR-101- Universal Counter, HP 53132A (Opt-012-030)- Universal Counter, Advantest TR5822- Microwave Frequency Counter, HP 5352B- Synthesizer-Level Generator, Anritsu MG443B- Signal Generator, HP ESG-4000A- ESGD Series Signal Generator, HP E4433B- Synthesized Sweeper, HP 8340B- Synthesized Sweeper, HP 83620A- Synthesized Sweeper, HP 83640A- Func./Arb. Waveform Generator, HP 33220A- Func./Arb. Waveform Generator, HP 33250A- Photo/Contact Tachometer , Digicon DT-251TL

- Freq.: 1MHz, 5MHz, 10MHz- Freq.: 1Hz ~ 3GHz- Freq.: 1Hz ~ 120MHz- Freq.: 100MHz ~ 40GHz- Freq.: 10H ~ 30MHz- Freq.: 100kHz ~ 4GHz- Freq.: 250kHz ~ 4GHz- Freq.: 10MHz ~ 26.5GHz- Freq.: 10MHz ~ 20GHz- Freq.: 10MHz ~ 40GHz- Freq.: 1Hz ~ 20MHz- Freq.: 1Hz ~ 80MHz- Rev. : 0.5rpm ~ 9000rpm

Standard Equipment: Functions/Ranges:

- RF Power Meter, HP436A, E4419B, EPM442A- RF Power Meter, Anritsu ML4803A- Power Sensor, HP 8482A, HP 8481A, HP 8482B, HP8484A- Power Sensor, HP E4412A, HP E9301A, HP E4413A- Power Sensor, Anritsu MA4601A, Anritsu MA4602A- Range Calibrator, HP 11683A, HP 8477A- Range Calibrator, Anritsu MA4001A- Measuring Receiver, HP 8902A/11722A- Spectrum Analyzer, HP8593E ,HP8564E, HP E4406A- Selective Level Meter, Anritsu ML422C- Signal Generator, HP ESG-4000A, HP E4433B- Signal Generator, HP 83620A, HP 83640A, HP 8340B- Syntesized Level Generator, Anritsu MG443B, - RF Power Amplifier, 25WI000M7- RF Power Splitter, HP 11667A, HP 11667B

- RF Power: 50Ω, 0.1nW - 25W (100kHz - 40GHz)- RF Power: 75Ω, 0.1nW - 100mW (100kHz - 2GHz)- RF Power: 50Ω, 0.1µW - 100mW (10MHz - 18GHz)- RF Power: 50Ω, 0.1µW - 100mW (10MHz - 26.5GHz)- RF Power: 75Ω, 0.1nW - 100mW (100kHz - 2GHz)- RF Power: 50Ω, 0.1nW - 25W (100kHz - 40GHz)- RF Power: 75Ω, 0.1nW - 100mW (100kHz - 2GHz)- RF Power: 50Ω, -127dBm~30dBm (100kHz - 1.3GHz)- RF Power: 50Ω, -120dBm~30dBm (30Hz - 40GHz)- RF Power: 50~600Ω, -120dBm~30dBm (50Hz - 30MHz)- RF Power: 50Ω, -120dBm~20dBm (100kHz - 4GHz)- RF Power: 50Ω, -20dBm~20dBm (10MHz - 40GHz)- RF Power: 50~600Ω, -120dBm~30dBm (50Hz - 30MHz)- RF Power: 50Ω, Max. 25W (25MHz - 1GHz)- RF Power: 50Ω, -120dBm~30dBm (100kHz - 40GHz)

Standard Equipment Ranges:- Rubidium Frequency Standard, R&S XSRM- Frequency Converter, R&S XSRM

# - GPS Time and Frequency Standard Receiver, HP 58503A

- Freq.: 5 MHz- Freq.: 0.1~10MHz- Freq.: 10 MHz

Standard Equipment RF Power Ranges:- Power Sensor, HP 8481A- Power Sensor, HP 8482A

- 50Ω, 1µW~100mW (10MHz~18GHz)- 50Ω, 1µW~100mW (100kHz~4.2GHz)

Standard Equipment RF Power Ranges:- Power Sensor, HP E4413A- Power Sensor, HP 8487A- Power Sensor, HP 8483A

- 50Ω, 0.1nW~100mW(100MHz~26.5GHz)- 50Ω, 1µW~100mW (50MHz~50GHz)- 75Ω, 1µW~100mW (100kHz~2GHz)

National Institute of Metrology (Thailand), NIMT

Agilent Technologies (USA)(ACLASS no.: 1498)

National Institute of Standards and Technology(NIST), USA

Agilent Technologies (Singapore)(SAC no.: 0169)

NSC-TISI-TIS 17025

Calibration No. 0289

NA Caltechnologies Co., Ltd.75/107 M. 11, Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466

Page 6: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

Accredited

Laboratories

NA's Highest

Standards

NA's Working

Standards

Customer's

Equipment

Remark:

Page 12 * Accredited scopes only ACV, DCV and frequency only FEZ-0009-G-Form-03/V6 /01/11/16

* ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Office of the National Standardization Council of Thailand (ONSC), Thai Industrial Standards Institute, Ministry of Industry (TISI)).

01-Nov-04 Jamno Yanyong

22-Nov-07

Traceability Chart

Prepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Cal. Manager)

Date: 26-Jan-17

Scope: Electrical Calibration (5)(RF Att./SWR/TV/Tel/Flutter/Jitter/LF)

RF Attenuation/Impedance From RF Power Sources/Meters:Modulation Meters/Sources: - * Digital/Analog Radio Testers/generators- * AM/FM/Phase Modulation Analyzers/Generators

- RF Attenuators- RF Attenuators- RF Attenuators- RF Attenuators- RF Termination/Calibration Kit- RF Termination/Calibration Kit- RF Impedance from Signal Sources- RF Impedance from Signal Meters- RF Attenuation from Signal Sources

- RF Attenuation from Signal Meters

Standard Equipment: Ranges:

- Fixed Att. Set, HP 8492A Series- Fixed Att. Set, Tektronix 011-0059- Fixed Att. Set, Weinschel Model 2 Series- VHF Attennuator, HP 355C/355D- Decade Attenuator, Ando AL352

- Network Analyzer, HP 8753D- Network Analyzer, Agilent 8722ES- Calibration Kit, HP85031B,85032B,85036B- Calibration Kit, Wiltron 3652

- 50Ω BNC, N, APC 3.5mm(0~120dB, DC~40GHz)

- 600/75Ω Balance(0~91dB, DC~700kHz)

- 50Ω BNC, N, APC 3.5mm(0~120dB, DC~40GHz)

Standard Equipment:

Standard Equipment Ranges:- Fixed Attennuator Set, Weinschel 44's- Fixed Attennuator Set, Agilent 8493C- Fixed Attennuator Set, Wiltron 41KC-S- Decade Attennuator, Anritsu MN61B- Termination, Wiltron 26N50, 26NF50- Termination, Wiltron 28A50- Termination, Maury 351A, 351B- Termination, Wiltron 28K50, 28KF50- Termination, Wiltron 26N75, 26NF75- Termination, HP 902C, 902D

- 50Ω: 10~40dB (DC~18GHz)- 50Ω: 30~40dB (DC~26.5GHz)- 50Ω: 3~20dB (DC~40GHz)- 75Ω: 0~91dB (DC~1.5GHz)- 50Ω: Type N (DC~18GHz)- 50Ω: Type APC 7mm (DC~18GHz)- 50Ω: Type BNC (DC~10GHz)- 50Ω: Type K (DC~40GHz)- 75Ω: Type N (DC~8GHz)- 50Ω: Type 3.5mm (DC~26.5GHz)

Standard Equipment:

- Modulation Analyzer 8901B

- Multimeter, HP3458A, 34411A, 34401A- Multi Product Calibrator, 5520A, 5500A- Oscilloscope,Tektronix TDS684B,TDS540A- Measuring Receiver HP8902A- Audio Analyzer, VP7725A, HP 8903B- Telephone Unit Tester, Ando AE9303- Impulse Sender, Ando AE-3106- Wow Flutter/CD/DVD Jitter Calibrator,Minato 3101, Act 3901- Rubidium Frequency Standard, Sansei FSR-101- Universal Counter, HP53132A.012.030, Advantest TR5822

Standard Equipment: Ranges:

National Institute of Standards and Technology

National Institute of Metrology (Thailand), NIMT

TV Signal Analyzers/Sources Instruments:- PAL Pattern Generators- NTSC Pattern Generators- PAL Vector Scopes- NTSC Vector Scopes- Video Generators- Video Analyzers- Video Noise Meters- Video Pattern Generators

Other LF/Audio/Modulation Instruments:- * Audio Analyzers/Generators- * CD Jitter Meters/Calibrators- * CD/MD Tracking Offset/Phase Meters/Generators- * DVD Jitter Meters/Calibrators- * VTR Jitter Meters/Generators- * WOW Flutter Meters/Generators- Telephone Unit Analyzers/Generators- Bell Ringer Analyzers/Generators- * Digital/Analog Radio Testers/generators- * AM/FM/Phase Modulation Analyzers/Generators- * Distortion Analyzers/Generators- * Oscilloscopes/Oscilloscopes Calibrators

- 50Ω: 0~100dB, DC~40GHz- 75Ω: 0~90dB, DC~1.5GHz- 75Ω Balance: 0~91dB, DC~700kHz- 600Ω Balance: 0~91dB, DC~150kHz- 50Ω: DC~40GHz- 75Ω: DC~1.5GHz- 50Ω: DC~40GHz, 75Ω: DC~1.5GHz- 50Ω: DC~40GHz, 75Ω: DC~1.5GHz- 50Ω: 0~100dB, DC~40GHz,

75Ω: 0~90dB, DC~1.5GHz- 50Ω: 0~100dB, DC~40GHz,

75Ω: 0~90dB, DC~1.5GHz

Standard Equipment:

- Measuring Receiver HP8902A

Standard Equipment:

- Signal Generator,Tektronix TG2000

- Mixed Signal AudioMeasurment Set,

Tektronix AM700- NTSC TV Generator,

Tektronix 1410- PAL TV Generator,

Tektronix 1411- Video MeasurementSystem,Tektronix VM700T

Level:- Digital Multimeter, Agilent 3458A- AC Measureing Standard, Fluke 5790A+Wide Band- Multi-Function Calibrator, Fluke 5720A- Multi-Function Calibrator, Fluke 5700A+Wide Band

Frequency:- Rubidium Frequency Standard, R&S XSRM

Level:- DCV/ACV: 0~700V (10Hz~10MHz)- ACV: 0~1kV (10Hz~30MHz)- DCV/ACV: 0~1kV (10Hz~1MHz)- DCV/ACV: 0~1kV (10Hz~30MHz)

Frequency:- Freq.: 0.1MHz, 1MHz, 5MHz, 10MHz

Thai Aviation Industries(TLASS no.: 0146)

NSC-TISI-TIS 17025

Calibration No. 0289

NA Caltechnologies Co., Ltd.75/107 M. 11, Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466

Page 7: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

NA's Highest

Standards

Wavelength Attenuation Power

NA's Working

Standards

Customer's

Equipment

Page 13 FEZ-0009-G-Form-03/V6 /01/11/16

01-Nov-04 Jamnong Yanyong

Traceability Chart

01-Nov-04 Jamnong

22-Nov-07

Prepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Cal. Manager)

Date: 26-Jan-17

Scope: Electrical Calibration (6)(Optical)

Optical Wavelength / Optical Components / Optical Powers: - Laser Sources / Lightwave Meters- Lightwave Switchs- Lightwave Transmitters / Receivers- Optical Spectrum Analyzers- Optical Time Domain Reflectmeters- Plug in Modules- Polarization

- Optical Attenuators- Optical Direction Couplers- Optical Grating Filters- N2X Card- NIC

- Communication Test Sets- Infiniium DCA- Laser Diode Drivers- OmniBER Communication Analyzers- Optical Power Meters / Power Sensors

- Single Mode Clock Recovery- SONET Transmittion Test Set- SpectralBER DWDM Module- SunSet- SunLite- T-Bird T-Carrier Analyzers

- Data Communication/Digital Communication Analyzer- 20GHz Optical/Electrical Converter- SONET/SDH Analyzer

- Agilent 83480A/83485A (2.488Gb/s), 83480A/83485B (9.953Gb/s)- Agilent 83440C (DC~20GHz)- Anritsu MP1570A (10G)

- Polarization Controller- Return Loss Module- Optical Directinal Coupler

- Agilent 8169- Agilent 81534A- Anritsu MN9604B

- Laser Source, Agilent 81640A/81650A/81689A- LD Source, Anritsu MG0938C / Anritsu MG9002A

(1310, 1510~1640 nm)

Optical Spectrum Analyzer,Anritsu MS9710B

(1300~1550 nm, -10~-50dBm)

Optical Attenuator,Agilent 8156A / Anritsu MN9605C

(1300~1550 nm, 1~60dB)

Optical Power Sensors,Agilent 81521B/81525A/81532A

(1300~1550 nm, +27~-110dBm)

Optical Power Sensors,Agilent 81624A

(1300~1550 nm, +10~-90dBm)

Optical Attenuator,Agilent 8156A

(1300~1550 nm, 1~60dB)- Lightwave Multi-Meter, Agilent 8153A- Multi-Wavelength Meter, Agilent 86120C

- Lightwave Measurement System, Agilent 8164A- Lightwave Multimeter, Agilent 8163A

Wavelength MeterBurleigh WA-1600

National Institute of Metrology (Thailand), NIMT

NSC-TISI-TIS 17025

Calibration No. 0289

NA Caltechnologies Co., Ltd.75/107 M. 11, Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466

Page 8: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

NA's Highest

Standards

NA's Working

Standards

Customer's

Equipment

Remark:

Page 1 FEZ-0009-G-Form-03/V6 /01/11/16

* ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Office of the National Standardization Council of Thailand (ONSC), Thai Industrial Standards Institute, Ministry of Industry (TISI)).

NA Caltechnologies Co., Ltd.75/107 M. 11, Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466

Prepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Act. for Dept.Mgr.)

Date: 26-Jan-17

Traceability Chart

Scope: Dimensional Calibration (1)

- Gauge Blocks *- Long Gauge Block

(Steel, Ceramic, Carbide)

Grade 0, 1, 2- Snap Gauge

Range: 0.1~500mm

- Calibration Testers *- Dial Gauge Testers *- Coating Thickness

Plates- Linear Probes- Check Masters- Master Bars- Setting Bars

Range: 0~500mm

- Caliper Checkers*- Depth Micro-Checkers*

- Height Masters- Riser Blocks

Range: 0~670mm

- Outside Micrometers (0~1000mm)*- Inside Micrometers (0~300mm)*- Depth Micrometers (0~300mm)*- Thickness Gauges (0~100mm)*- Height Gauges (0~1000mm)*

- Calipers (0~ 1500mm)*- Depth Gauges (0~600mm)- Caliper Gauges (0~300mm)

- Micrometer Heads (0~100mm)- Electrical Comparators (0~10mm)*

- Precision Levels (0~5mm/m)*

- Electric Levels (0~5mm/m)*

Others Instrument- Straightness Edge

- Horizontal Length Machines- Universal Length Measuring

Machines- Coating Thickness Gauges

Range: 0~1000mm

Gauge Block Set(Grade K, 0) Laser Hologauge

(Uncert: 0.1µm)

Gauge Block Set(Grade K, 0, 1) - Gauge Block Set (Grade 0, 1, 2)

- Long Gauge Block Set (Grade 0, 1)- Caliper Checkers

- Depth Micro-Checkers- Precision Surface Plates (Grade 0)

(Uncertainty: 0.07~3.0µm)

- Angle Generator- Laser Hologauge

- Digimatic Indicator- Gauge Block Set

(Grade 0, 1, 2)

(Uncertainty: 0.07~2.0µm)

- Gauge Block Set(Grade 0, 1, 2)

- Long Gauge Block Set(Grade 0, 1)

- Precision Surface Plates(Grade 0)

(Uncertainty: 0.07~0.20µm)

- Long Gauge Block Set (Grade K, Range 100~500mm)(Uncertainty: 0.04~0.20µm)

- Gauge Block Set (Grade K, Range 0.1~100mm)(Uncertainty: 0.02~0.04µm)

National Institute of Metrology (Thailand), NIMTNational Measurement Institute (NMIA),

AustraliaNational Metrology Institute of Japan (NMIJ)

Range: < 100mmElectronic Comparator(Uncertainty: 0.03µm)

Range: >100~500mmUniversal Length M/C(Uncertainty: 0.30µm)

Electronic Comparator(Uncertainty: 0.1µm)

Precision Surface Plate (Grade 0)

(Uncertainty: 1.5µm)

Universal Length Measuring M/C(Uncert: 0.3µm)

NSC-TISI-TIS 17025

Calibration No. 0289

Page 9: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

NA's Highest

Standards

NA's Working

Standards

Customer's

Equipment

Remark:

Page 2 FEZ-0009-G-Form-03/V6 /01/11/16

Digital Indicator

* ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Office of the National Standardization Council of Thailand (ONSC), Thai Industrial Standards Institute, Ministry of Industry (TISI)).

Prepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Act. for Dept.Mgr.)

Date: 26-Jan-17

Traceability Chart

Scope: Dimensional Calibration (2)

- Feeler Gauges

Range:0.1~10mm

- Dial Gauges- Dial Test Indicators

- Bore Gauges- Cylinder Gauges

Range:0~500mm

- Pin Gauges- Plug Gauges- Laser Scan Micrometers- Three Wires

Range:0.1~500mm

- Profile Projectors- Measuring

Microsocopes- Scale Loops

Range:0~300mm

- Holtest

Range: 2~100mm

- Surface Plates

Size: All*

- Glass Scales- Angle Gauges- Radius Gauges- Taper Gauges- Metal Rules

Range: 0~300mm

- Protactors

Range:0~90o

Digimatic Indicator

Uncertainty: 1.0µm

Calibration TestersUncertainty: 0.4µm

Standard Pin Gauge Set

Uncert: 0.2~0.5µm

- Thread Plug Gauges

- Thread Ring Gauges

- Setting Ring GaugesRange:

1~250mm

3-Wire Set / Ruby Ball Set

Microscope Calibrator

Uncertainty: 1.0µm

- Standard Glass ScaleUncertainty: 0.3µm

Angle Gauge Set

- CMM

Range: 0~1000mm

- Steel Tape- Metal Rule

Text Tile Tape

Range: >300mm

Ring Gauge Set

Uncert:

0.5µm

3-D MasterUncert: 0.5µm

Scale Calibrator Uncert: 1.0µm

Electronic Level Meter

Uncert: 1.8µm

National Institute of Metrology (Thailand), NIMT

Laser Hologauge(Uncertainty: 0.1µm)

Gauge Block Set / Long Gauge Block Set (Grade K)(Uncertainty: 0.02~0.30µm)

Universal Length Measuring M/C(Uncertainty: 0.30µm)

Standard Ring Gauge Set

Laser Scan Micrometer

Uncert: 0.5µm

Scale Calibrator(Used for Comparison/Direct reading)

Working Glass Scale

Uncertainty: 1.0µm

NSC-TISI-TIS 17025

Calibration No. 0289

NA Caltechnologies Co., Ltd.75/107 M. 11Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466

Page 10: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

NA's Highest

Standards

NA's Working

Standards

Customer's

Equipment

Remark:

Page 3 FEZ-0009-G-Form-03/V6 /01/11/16

* ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Office of the National Standardization Council of Thailand (ONSC), Thai Industrial Standards Institute, Ministry of Industry (TISI)).

Traceability ChartPrepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Act. for Dept. Mgr.)

Date: 26-Jan-17

Scope: Mass Calibration

- Steel Weights *- Brass Weights *

- Stainless Steel Weights *- Other Material Made Weights *

OIML Class F1, F2

Range: 1mg~20kg

- Steel Weights *- Brass Weights *

- Stainless Steel Weights *- Other Material Made Weights *

OIML Class F2, M1, M2, M3, No-Class

Range: 1mg~20kg

- Electronic Balances *- Spring Balances *- Other Balances *

Range: 0g~500kg

- Standard Weight Set, OIML Class E2(Mettler-Toledo)

- Mass Comparator, Mettler-Toledo, AT201- Mass Comparator, Mettler-Toledo, PR2004

- Mass Comparator, Mettler-Toledo, KA30-3/P

Range: 1mg~20kg

- Standard Weight Set, OIML Class F1(Mettler-Toledo)

- Standard Weight Set, OIML Class F1(Kern)

- Mass Comparator, Mettler-Toledo, AT201- Mass Comparator, Mettler-Toledo, PR2004

- Mass Comparator, Mettler-Toledo, KA30-3/P

Range: 1mg~20kg

- Standard Weight Set, OIML Class E2, F1(Mettler-Toledo)

- Standard Weight Set, OIML Class F1(Kern)

- Standard Weight Set, OIML Class F2(Moriya)

Standard Weight Set, OIML Class M1(Moriya)

Range: 1mg~500kg

National Institute of Metrology (Thailand), NIMT

- Standard Weight Set, OIML Class E2 (Mettler-Toledo)Range : 1mg~20kg

NSC-TISI-TIS 17025

Calibration No. 0289

NA Caltechnologies Co., Ltd.75/107 M. 11, Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466

Page 11: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

NA's Highest

Standards

NA's Working

Standards

Customer's

Equipment

Remark:

Page 4 FEZ-0009-G-Form-03/V6 /01/11/16

* ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Office of the National Standardization Council of Thailand (ONSC), Thai Industrial Standards Institute, Ministry of Industry (TISI)).

Prepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Act. for Dept. Mgr.)

Date: 26-Jan-17

Traceability Chart

Scope: Force Calibration

Force Measuring Instrument- Push-Pull Scales *- Tension Gauges *

- Dial Tension Gauges *- Force / Digital Force Gauge *

Range: 0~200kgf

Force Machines (On-site)- Tensile Testing Machines

- Autograph Machines

Range: 0~50kN

- Standard Weight Set, OIML Class E2, F1(Mettler-Toledo)

- Standard Weight Set, OIML Class F1 (Kern)- Standard Weight Set, OIML Class F2 (Moriya)- Standard Weight Set, OIML Class M1 (Moriya)

- Hook / Slot Weight Set (RRK)

Range: 1mg~200kg

- Digital Force Indicator (HBM)- Load Cell Standard (HBM)

Range: 0~50kN

- Standard Weight Set, OIML Class E2 (Mettler-Toledo)Range : 1mg~20kg

National Institute of Metrology (Thailand), NIMT

NSC-TISI-TIS 17025

Calibration No. 0289

NA Caltechnologies Co., Ltd.75/107 M. 11, Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466

Page 12: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

NA's Highest

Standards

NA's Working

Standards

Customer's

Equipment

Remark:

Page 5 FEZ-0009-G-Form-03/V6 /01/11/16

* ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Office of the National Standardization Council of Thailand (ONSC), Thai Industrial Standards Institute, Ministry of Industry (TISI)).

Prepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Act. for Dept. Mgr. )

Date: 26-Jan-17

Traceability Chart

Scope: Torque Calibration

Torque Measuring Devices- Digital / Mechanical Torque Testers

Range: 0~2,000kgf.cm

- Torque Transducer (Norbar)- Digital Torque Meter (HIOS)

- Digital Torque Analyzer (KANON)- Torque Driver Tester (Tohnichi)

Range: 0~1500 Nm

- Hook / Slot Weight Set (RRK)Range: 0~200kg

- Beam Standard (Hios, Kanon, RCE)Range: 1cm~40cm

- Gauge Block Set Grade KRange : 0.5mm~500mm

National Institute of Metrology (Thailand), NIMT

Torque Instruments- Torque Gauges

- Torque Wrenches *- Torque Screw Drivers *

Range: 0~1500 Nm

- Standard Weight Set, OIML Class E2 (Mettler-Toledo)

NSC-TISI-TIS 17025

Calibration No. 0289

NA Caltechnologies Co., Ltd.75/107 M. 11, Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466

Page 13: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

NA's Highest

Standards

NA's Working

Standards

Customer's

Equipment

Remark:

Page 6 FEZ-0009-G-Form-03/V6 /01/11/16

* ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Office of the National Standardization Council of Thailand (ONSC), Thai Industrial Standards Institute, Ministry of Industry (TISI)).

Prepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Cal. Manager)

Date: 26-Jan-17

Traceability Chart

Scope: Temperature Calibration

NSC-TISI-TIS 17025

Calibration No. 0289

Temperature Sensors:- Thermocouple Sensors *- Thermocouple Extension Wire*

(Type E / J / K / N / T)- RTD Sensors *

Range: -20oC~700oC

Thermometers:- Liquid-in-glass Thermometers *- Thermometer With Sensors *(Analog / Digital)

- Recorder With Sensors *- Surface Thermometers

Range: -20oC~700oC

Temperature Sources:- Dry Block Calibrators *- Liquid Bath *- Chambers, Oven *- Incubators, Autoclave *

Range: -40oC~1,000oC

Thermo-Hygro:- Thermo-Hygrographes *- Thermo-Hygrometers *

(Analog / Digital)- Humidity Transmitter

Range: Tem. 0oC~50oCHum. 20%~90%rh

Temperature Indicators / Simulators:

- Hybrid Recorders *- Reflow / Soldering Testers *- Data Logger / Thermometer *- Process Calibrators *- Temperature Calibrators *

Range: TC all type, RTD all type

Standard Sensors and Thermometers: Temperature Sources:- PRT Standard Sensor (Asahi), Pt-100 - PRT Standard Sensor (Anritsu), Pt-100 - PRT Standard Sensor (Netsushin), Pt-100 - PRT Standard Sensor (Fluke, 5626), Pt-100 - Type S Thermocouple (High Temp.) - Type T Thermocouple Set (RS) - High Precision LIG Thermometers (Nippon Kei) - Black Stack Thermometer (Hart 1560, 2562)- Reference Junction Set (Type E, J, K, N, R, S, T)- Data Logger With RTD Sensor (Agilent 34970A)- Digital Thermometer (Yokogawa 7563-21)- High Precision Thermo-Hygrometer (Rotronic HF535)

- Dry Block Calibrator (Hart Scientific, 9105)- Dry Block Calibrator (Hart Scientific, 9122A)- Surface Calibrator (Anritsu ACSII)- Liquid Bath (Jubalo)- Temperature / Humidity Controlled Chamber (Espec, PR1KP)- High Precission Bath ( Fluke, 6331 )- High Precission Bath ( Fluke, 7341)

- Dry Block Calibrator (Fluke, 9102S)

- Dry Block Calibrator (Fluke, 9100S)- Surface Calibrator (Fluke, 3125)

Standard Simulators:- Multi-Product calibrators(Fluke 5500A, 5520A)

- Process Calibrator(Fluke 744)

Standard Indicators:- Digital Multimeter(Agilent 3458A)

- Digital Thermometer(Yokogawa 7563-21)

- SPRT Standard (Hart Scientific, 5626)- Type S Standard Thermocouple (High Temp.)

- Thermo-Hygrometer (Fluke 1620A)

- Multi-Function Calibrator(Fluke 5720A)

- DCV Standard (Fluke 732B)

National Institute of Metrology (Thailand), NIMT

NA Caltechnologies Co., Ltd.75/107 M. 11, Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466

Page 14: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

NA's Working

Standards

Customer's

Equipment

Remark:

Page 7 FEZ-0009-G-Form-03/V6 /01/11/16

* ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Office of the National Standardization Council of Thailand (ONSC), Thai Industrial Standards Institute, Ministry of Industry (TISI)).

Prepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Cal. Manager)

Date: 26-Jan-17

Traceability Chart

Scope: Temperature Calibration (2)Infrared Temperature

Thermometers:

- Infrared Thermometer- Thermal Image- Thermal Camera- Thermo Gear

Range: -40oC~500oC

Temperature Sources:

- Precission Infrared Calibrator ( Fluke, 4181 )

- High Precission Bath ( Fluke, 7341 )

National Institute of Metrology (Thailand), NIMT

NSC-TISI-TIS 17025

Calibration No. 0289

NA Caltechnologies Co., Ltd.75/107 M. 11, Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466

Page 15: Calibration Traceability Chart - NA Caltechnologies · NA Caltechnologies Co., Ltd. National Standard Accredited Laboratories NA's Highest Standards NA's Working Standards Customer's

National Standard

NA's Highest

Standards

NA's Working

Standards

Customer's

Equipment

Remark:

Page 14 FEZ-0009-G-Form-03/V6 /01/11/16

Prepared by:

(Technical Manager)

Date: 26-Jan-17

Approved by:

(Technical Manager)

Date: 26-Jan-17

Traceability Chart

Scope: Other Scopes of Calibration (1)

- Rubber Hardness Testers

- Duro Meters

(JIS / ASTM Type)(0~100o)

- Pressure Gauges- Pressure Transducer

- Pressure Switch- Pressure Indicator

(0~70Mpa) or quivalent unit

Roughess Testers

(Ra, Ry)

(4.2µRa/10µRy)

- Viscosity Testers- Viscosity Meters

(129~200,500 mPa.s)

pH Meter(With Probes)

(pH 4~10)

Conductivity(With Probes)

(0.1nS~1S)

Duro Meter Tester (Teclock)

Range: 0~100o

- Hydraulic Dead Weight Tester

(Nagano)-Digital Test Gauge

-Pressure Calibrator

Range: 0~70 MPa

Standard Block for Hardness

(NIMT/Yamamoto)

Roughness Standard(Kosaka Laboratory)

Standard Liquid for Calibrating Viscometers

(Nippon Grease/CANNON)

(N75/N140/N4000/N5100/

JS 500/JS1,000/JS2000/JS14000/

JS160000)

pH Solution Standard

(Mettler-Toledo)

(pH 4~10)

- Conductivity Solution Standard(Mettler-Toledo)

- Decade Resistance Boxes

(0.1nS~1S)

Standard Weight Set, OIML Class E2 (Mettler-Toledo)

National Institute of Metrology (Thailand), NIMT

Digital Multimeter (Agilent 3458A)

National Institute of Standard and Technology, U.S.A.

National Metrology Institute of Japan (NMIJ), Japan

-Buret-Micropipet

- Measuring Pipet-Volumetric Pipet-Volumetric Flask

(0~2000ml) or quivalent unit

Standard Weight Set, OIML Class E2 (Mettler-Toledo)

Electronic Balance (Mettler Toledo)

Hardness Testing Machines

(Vicker / Rockwell)

(HMV, HRC, HRB)

NSC-TISI-TIS 17025

Calibration No. 0289

NA Caltechnologies Co., Ltd.75/107 M. 11, Klongnueng, Klongluang, Pathumthani 12120 THAILANDTel. (+66) 2-529-2460 (Auto)Fax. (+66) 2-529-2466