calibration of clinometers for the alignment of muon chambers in the cms experiment. moschoutis...

12
Calibration of Calibration of clinometers for the clinometers for the alignment of muon alignment of muon chambers in the CMS chambers in the CMS experiment. experiment. MOSCHOUTIS Thomas MOSCHOUTIS Thomas FAS meeting – Orlando, 12 March 2004

Upload: tiffany-holmes

Post on 18-Dec-2015

219 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Calibration of clinometers for the alignment of muon chambers in the CMS experiment. MOSCHOUTIS Thomas FAS meeting – Orlando, 12 March 2004

Calibration of clinometers Calibration of clinometers for the alignment of muon for the alignment of muon

chambers in the CMS chambers in the CMS experiment. experiment.

MOSCHOUTIS ThomasMOSCHOUTIS Thomas

FAS meeting – Orlando, 12 March 2004

Page 2: Calibration of clinometers for the alignment of muon chambers in the CMS experiment. MOSCHOUTIS Thomas FAS meeting – Orlando, 12 March 2004

Global view of the Compact Muon Global view of the Compact Muon SolenoidSolenoid

Page 3: Calibration of clinometers for the alignment of muon chambers in the CMS experiment. MOSCHOUTIS Thomas FAS meeting – Orlando, 12 March 2004

View of one DiskView of one Disk

Dual-axis clinometers for monitoring orientation of transfer pates:

Page 4: Calibration of clinometers for the alignment of muon chambers in the CMS experiment. MOSCHOUTIS Thomas FAS meeting – Orlando, 12 March 2004

Calibration benchCalibration bench

CIinometer

sensing Liquid

calibrated Linear mover

Θ

Page 5: Calibration of clinometers for the alignment of muon chambers in the CMS experiment. MOSCHOUTIS Thomas FAS meeting – Orlando, 12 March 2004

First setupFirst setup

Clinometer’s placeLinear mover

Page 6: Calibration of clinometers for the alignment of muon chambers in the CMS experiment. MOSCHOUTIS Thomas FAS meeting – Orlando, 12 March 2004

Error calculationError calculation

Error in Error in φφ::• φφ =Tan =Tan-1-1(L/H) (L/H) • ΔφΔφ=(∂=(∂φφ/∂L)*/∂L)*ΔΔL+(∂L+(∂φφ/∂H)*/∂H)*ΔΔH H

=(1/(L+H))*=(1/(L+H))*ΔΔL-2L/(HL-2L/(H22+H*L)*+H*L)*ΔΔHH Using the same formula:Using the same formula:

• ΔΩΔΩ=(1/(L+M))*=(1/(L+M))*ΔΔL-2L/(ML-2L/(M22+M*L)*+M*L)*ΔΔMM Taking Taking ρρ=cos-1(M/K) and M=0=cos-1(M/K) and M=0

• ΔρΔρ==ΔΔM/KM/K So the total error is:So the total error is:

• ΔθΔθ =( =(ΔφΔφ22++ΔΩΔΩ22++ΔρΔρ22))1/21/2

MK

ρρ

φφ

LL

HH

Page 7: Calibration of clinometers for the alignment of muon chambers in the CMS experiment. MOSCHOUTIS Thomas FAS meeting – Orlando, 12 March 2004

First test curveFirst test curve

Angle vs clinometer voltage output

-5

0

5

10

15

20

25

30

-3.0 -2.5 -2.0 -1.5 -1.0 -0.5 0.0 0.5 1.0 1.5 2.0

Response Voltage [V]

An

gle

[D

eg

ree

s]

Page 8: Calibration of clinometers for the alignment of muon chambers in the CMS experiment. MOSCHOUTIS Thomas FAS meeting – Orlando, 12 March 2004

Zero degree measurementZero degree measurement

Pendulum

clinometer

Long rod to get more precision

Page 9: Calibration of clinometers for the alignment of muon chambers in the CMS experiment. MOSCHOUTIS Thomas FAS meeting – Orlando, 12 March 2004

Problem induce by the plate Problem induce by the plate thicknessthickness

Page 10: Calibration of clinometers for the alignment of muon chambers in the CMS experiment. MOSCHOUTIS Thomas FAS meeting – Orlando, 12 March 2004

Second test curve Second test curve

Angle vs clinometer voltage output

0

2

4

6

8

10

12

14

16

-2.0 -1.5 -1.0 -0.5 0.0 0.5 1.0 1.5

Response voltage [Volts]

An

gle

[D

egre

es]

Page 11: Calibration of clinometers for the alignment of muon chambers in the CMS experiment. MOSCHOUTIS Thomas FAS meeting – Orlando, 12 March 2004

The 6 different mounting platesThe 6 different mounting plates

Clinometer’s place

Page 12: Calibration of clinometers for the alignment of muon chambers in the CMS experiment. MOSCHOUTIS Thomas FAS meeting – Orlando, 12 March 2004

Next setupNext setupLinear mover

Adapter

Tilting base

Mounting plate

Click here to see movie