calibration admixture
TRANSCRIPT
-
8/17/2019 Calibration Admixture
1/2
Date: 12 / 04 /2016
F-11-041 (SRMI)
Plant: Boyolali Weighing model : Searbeam 100kg S/N Weighing:sonic FSR: 30 Kg._ (Max. of Scale) Page 1 / 1
Calibration Load Reading Error Calibration Load Reading Error Remark
Load Weight Before Load Weight After Correction
(Kg.) : A (Kg.) : B B - A (Kg.) : C (Kg.) : D D - C
0.0 0.0 0.0 0.0 0.0 0.0
0.5 0.52 0.02 0.5 0.50 0.00
1.0 1.02 0.02 1.0 1.00 0.00
1.5 1.54 0.04 1.5 1.50 0.00
2.0 2.05 0.05 2.0 2.00 0.00
2.5 2.56 0.06 2.5 2.50 0.00
3.0 3.07 0.07 3.0 3.00 0.00
3.5 3.59 0.09 3.5 3.50 0.00
4.0 4.10 0.10 4.0 4.00 0.00
4.5 4.61 0.11 4.5 4.50 0.00
5.0 5.13 0.13 5.0 5.00 0.00
2.30 2.30 0.00 Load admixture 2.30 kg
2.80 2.80 0.00
3.30 3.30 0.00
3.80 3.80 0.00
4.30 4.30 0.00
4.80 4.80 0.00
5.30 5.30 0.00
5.80 5.80 0.00
6.30 6.30 0.00
6.80 6.80 0.00
7.30 7.30 0.00
4.75 4.75 0.00 Load admixture 2.45 kg
5.25 5.25 0.00
5.75 5.75 0.00
6.25 6.25 0.00
6.75 6.75 0.00
7.25 7.25 0.00
7.75 7.75 0.00
8.25 8.25 0.00
8.75 8.75 0.00
9.25 9.25 0.00
9.75 9.75 0.00
7.12 7.12 0.00 Load admixture 2.37 kg
7.62 7.62 0.00
8.12 8.12 0.00
8.62 8.62 0.00
9.12 9.12 0.00
9.62 9.62 0.00
10.12 10.12 0.00
10.62 10.62 0.00
11.12 11.12 0.00
11.62 11.62 0.00
12.12 12.12 0.00
9.60 9.60 0.00 Load admixture 2.48 kg
10.10 10.10 0.00
10.60 10.60 0.00
11.10 11.10 0.00
11.60 11.60 0.00
12.10 12.10 0.00
12.60 12.60 0.00
13.10 13.10 0.00
13.60 13.60 0.00
14.10 14.10 0.00
14.60 14.60 0.00
12.09 12.09 0.00 Load admixture 2.49 kg
12.59 12.59 0.00
13.09 13.09 0.00
13.59 13.59 0.00
14.09 14.09 0.00
14.59 14.59 0.00
15.09 15.09 0.00
15.59 15.59 0.00
16.09 16.09 0.00
16.59 16.59 0.00
17.09 17.09 0.00
Error After Correction (14.60 kg)
Maximum = 0 kg
Minimum = 0 kg
Error After Correction (17.09 kg)
Maximum = 0 kg
Minimum = 0 kg
Calibration Record of ADMIXTURE Weighing
Mili Volt
0 kg = 4.479 mv
5 kg = 5.505 mv
Error Before Correction
Maximum = 0.13 kg
Minimum = 0.02 kg
Error After Correction (5 kg)
Maximum = 0 kg
Minimum = 0 kg
Error After Correction (7.3 kg)
Maximum = 0 kg
Minimum = 0 kg
Error After Correction (9.75 kg)
Maximum = 0 kg
Minimum = 0 kg
Error After Correction (12.12 kg)
Maximum = 0 kg
Minimum = 0 kg
-
8/17/2019 Calibration Admixture
2/2
14.50 14.50 0.00 Load admixture 2.41 kg
15.00 15.00 0.00
15.50 15.50 0.00
16.00 16.00 0.00
16.50 16.50 0.00
17.00 17.00 0.00
17.50 17.50 0.00
18.00 18.00 0.00
18.50 18.50 0.00
19.00 19.00 0.00
19.50 19.50 0.00
17.48 17.48 0.00 Load admixture 2.98 kg
17.98 17.98 0.00
18.48 18.48 0.00
18.98 18.98 0.00
19.48 19.48 0.00
19.98 19.98 0.00
20.48 20.48 0.00
20.98 20.98 0.00
21.48 21.48 0.00
21.98 21.98 0.00
22.48 22.48 0.00
20.70 20.70 0.00 Load admixture 3.22 kg
21.20 21.20 0.00
21.70 21.70 0.00
22.20 22.20 0.00
22.70 22.70 0.00
23.20 23.20 0.00
23.70 23.70 0.00
24.20 24.20 0.00
24.70 24.70 0.00
25.20 25.20 0.00
25.70 25.70 0.00
23.46 23.46 0.00 Load admixture 2.76 kg
23.96 23.96 0.00
24.46 24.46 0.00
24.96 24.96 0.00
25.46 25.46 0.00
25.96 25.96 0.00
26.46 26.46 0.00
26.96 26.96 0.00
27.46 27.46 0.00
27.96 27.96 0.00
28.46 28.46 0.00
Layout of Loadcell
S/N of Standard Weight: SBU2 01-10 Good Super Intendent = RANGGA SATRIA
Max of Scale: 5 kg less than +/- 0.2% FSR ( +/- 0.06 kg) Calibrated by SINGGIH S & DARSONO
Don't use stop produce for correction Approved by CHARUPAT UANSRAAD ( Brach Manager )
* การสอบเทยบตองทาในขณะท มแสงสวางเพยงพอ และไมดาเนนการสอบเทยบขณะฝนตก
*กรณท สงส ยัวาคาผดพลาด อยในระหวางยาน ท เคร องช ั งแสดงผลไม ได ใหใช ลกตมนาหนกั พกดั 0.5 กก. หรอตากวาเสรมเพ อหาคานาหนกัจรงในยานดงักลาว
Error After Correction (19.50 kg)
Maximum = 0 kg
Minimum = 0 kg
Error After Correction (22.48 kg)
Maximum = 0 kg
Minimum = 0 kg
Error After Correction (25.70 kg)
Maximum = 0 kg
Minimum = 0 kg
Error After Correction (28.46 kg)
Maximum = 0 kg
Minimum = 0 kg
1
2
1
2 4
3 1