CABLE TRAY LSS1 – VISIT MARCH 24 TH WITH Y. MUTTONI & G. CANALE Dorothea Pfeiffer LTEX Meeting 21.03.2013

Upload: audrey-little

Post on 16-Dec-2015

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CABLE TRAY LSS1 – VISIT MARCH 24 TH WITH Y. MUTTONI & G. CANALE Dorothea Pfeiffer LTEX Meeting 21.03.2013

CABLE TRAY LSS1 – VISIT MARCH 24TH WITH Y. MUTTONI & G. CANALE

Dorothea PfeifferLTEX Meeting 21.03.2013

Page 2: CABLE TRAY LSS1 – VISIT MARCH 24 TH WITH Y. MUTTONI & G. CANALE Dorothea Pfeiffer LTEX Meeting 21.03.2013

2

Cable tray for forward detectors

21.03.2013LTEX Dorothea Pfeiffer

LSS1L: Start of RR13 – UL14 From UL14 to TCL5 (shielding wall): 400

mm x 60 mm From TCL5 to RR13: 200 mm x 60 mm

(cable tray of EN-EL already installed) LSS1R: Start of RR17 – UL16

From UL16 to TCL5 (shielding wall): 400 mm x 60 mm

From TCL5 to RR17: 200 mm x 60 mm (cable tray of EN-EL already installed)

Page 3: CABLE TRAY LSS1 – VISIT MARCH 24 TH WITH Y. MUTTONI & G. CANALE Dorothea Pfeiffer LTEX Meeting 21.03.2013

3

In UL14/UL16 (on top of horizontal bar: 400 mm x 60 mm)

LTEX Dorothea Pfeiffer 21.03.2013

Or use the forward detector cable tray?

Page 4: CABLE TRAY LSS1 – VISIT MARCH 24 TH WITH Y. MUTTONI & G. CANALE Dorothea Pfeiffer LTEX Meeting 21.03.2013

4

UL14/UL16 to TCL5 (full height: 400 mm x 60 mm)

LTEX Dorothea Pfeiffer 21.03.2013

Page 5: CABLE TRAY LSS1 – VISIT MARCH 24 TH WITH Y. MUTTONI & G. CANALE Dorothea Pfeiffer LTEX Meeting 21.03.2013

5

TCL5 to RR13/17 (above EN-EL tray 200 mm x 60 mm)

LTEX Dorothea Pfeiffer 21.03.2013

Page 6: CABLE TRAY LSS1 – VISIT MARCH 24 TH WITH Y. MUTTONI & G. CANALE Dorothea Pfeiffer LTEX Meeting 21.03.2013

6

Volume of cables

LTEX Dorothea Pfeiffer 21.03.2013

  câbles entre AFP et USA15 (ou US15) par côté  

n° Item TypeNumber

Ø (mm)

From-To Notecm2

1 LV cables t.b.d. 2 18

AFP-USA15 or US15

For Si. If cable path length to US15 is much shorter, then the US15 chosen as arrival point

6.482 HV cables t.b.d. 2 6 0.723 Opto interface t.b.d. 4 10 4

4Voltage regulator

t.b.d. 1 101

6 CANBUS t.b.d. 1 12AFP1-USA15 For Si 1.448 DCS (CANBUS) t.b.d. 2 12AFP2-USA15 For Si and Ti 2.88

11 HVSCEM 04.31.52.050.8

1 11AFP2-USA15 For Ti1.21

12 LV t.b.d. 1 11AFP2-USA15 or US15

Same place as for Si1.21

15 Analog signal CMC50 20 15AFP-US15 BPM 45

16 Ethernet RJ45 5 6  BPM 1.8

17 Motor t.b.d. 2 20AFP-USA15 Movement system 8

18 Resolver t.b.d. 2 10AFP-USA15 Movement system2

19

Pressure, temperature, LVDT, switches+spares

t.b.d. 20 10AFP-USA15DCS for secondary vacuum, movement, etc..

20

   nbre câbles /côté 63    section câbles 95.74

Diameter needed, estimated by G. Canale