c30 microturbine natural gas - salvex natgas.pdf · ©2008 capstone turbine corporation. 01/08...
TRANSCRIPT
Power when and where you need it. Clean and simple.
Exhaust Characteristics (2) High Pressure Onboard Gas Compressor Option
NOx Emissions @ 15% O2 < 9 ppmvd < 9 ppmvd
NOx/Electrical Output (4) 0.193 g/bhp-hr (< 0.57 lb/MWh) < 0.60 lb/MWh (0.203 g/bhp-hr)
Exhaust Gas Flow 0.31 kg/s (0.69 lb/sec) 0.31 kg/s (0.69 lb/sec)
Exhaust Gas Temperature 275˚C (530˚F) 275˚C (530˚F)
Electrical Performance (2) High Pressure Onboard Gas Compressor Option
Electrical Power Output 30 kW 28 kW
Voltage 400 to 480 VAC 400 to 480 VAC
Electrical Service 3-Phase, 4 wire 3-Phase, 4 wire
Frequency 50/60 Hz, grid connect operation 50/60 Hz, grid connect operation
10/60 Hz, stand alone operation 10/60 Hz, stand alone operation
Maximum Output Current 46A, grid connect operation 46A, grid connect operation
54A, stand alone operation (3) 54A, stand alone operation (3)
Electrical Efficiency LHV 26% 25%
Fuel/Engine Characteristics (2) High Pressure Onboard Gas Compressor Option
Natural Gas HHV 825 to 1,275 BTU/scf 825 to 1,275 BTU/scf
Inlet Pressure – HHV dependent 3.8–4.1 barg (55–60 psig) 0.01–1.0 barg (0.2–15 psig)
Fuel Flow LHV 415 MJ/hr (394,000 BTU/hr) 403 MJ/hr (382,000 BTU/hr)
Generator Heat Rate LHV 12.9 MJ/kWh (12,200 BTU/kWh) 12.9 MJ/kWh (12,200 BTU/kWh)
Low NOx and CO• 2 emissions – better than tough global standardsOne moving part: Minimal maintenance and downtime•Patented air bearing: No lubricating oil or coolant•5 and 9 year Factory Protection Plans available•Remote monitoring and diagnostic capabilities•Integrated utility synchronization and protection• (1)
Small, modular design allows for easy, low-cost installation•Reliable: 16,000,000+ run hours and counting•
C30 MicroTurbineNatural Gas
Robust power system achieves ultra-low emissions and reliable electricity from natural gas.
C30 MicroTurbine
21211NordhoffStreet•Chatsworth•CA•91311•877.716.2929•818.407.3770•www.capstoneturbine.com
©2008 Capstone Turbine Corporation. 01/08 Capstone P/N 331031
(1) Some utilities may require additional equipment for grid interconnectivity(2) Nominal full power performance at ISO conditions: 59˚F, 14.696 psia, 60% RH(3) With linear load(4) Exhaust emissions with methane fuelSpecifications are not warranted and are subject to change without notice.
Dimensions & Weight Width x Depth x Height 762 x 1524 x 1956 mm (30 x 60 x 77 in)
Weight – Grid Connect Model 405 kg (891 lbs)
Weight – Dual Mode Model 578 kg (1,271 lbs)
Minimum Clearance RequirementsVertical Clearance 610 mm (24 in)
Horizontal Clearance
Left and Right 762 mm (30 in)
Front 940 mm (37 in)
Rear 915 mm (36 in)
Sound LevelsAcoustic Emissions at Full Load Power
Nominal at 10 m (33 ft) 65 dBA
CertificationsCertified to UL 2200 for stand alone natural gas operation (UL files AU2687, E209370)•
Meets statewide utility interconnection requirements for California Rule 21 and the New York State •Public Service Commission
Materials Equipment Acceptance (MEA) approval for New York City•
Models available with optional equipment for CE Marking•
C30 Net Power and Efficiencyat Ambient Temperature, Sea Level
30
25
5
10
15
20
0
Net P
ower
(kW
)
-5 0 10 20 30 40 50 60 70 80 90 100 110 120
Ambient Temperature (°F)
Net E
ffici
ency
(%)
30
25
5
10
15
20
0