BCI Systems
Brendan Allison, Ph.D.Institute for AutomationUniversity of Bremen29 January, 2008
![Page 2: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/2.jpg)
2
A BCI enables communication without movement.
Some patients cannot use any interface requiring movement.
What is a BCI?
![Page 3: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/3.jpg)
3
What is a BCI?
![Page 4: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/4.jpg)
4
Most BCIs translate your brain’s electrical activity (EEGs) into messages or commands.
Performing mental tasks produces electrical activity detectable with electrode caps.
What is a BCI?
![Page 5: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/5.jpg)
5
When a neuron is active, its voltage may change by 100 mV or more.
Electrical activity in a single neuron.
How do EEGs work?Neural communication
produces electrical activity.
![Page 6: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/6.jpg)
6
This activity may be detectable to electrodes on the scalp.
How do EEGs work?
Conventional electrode caps from EGI, Neuroscan, and Electro-Cap.
![Page 7: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/7.jpg)
7
Newer EEG recording systems:
• Require less or no prep time and skill• Require less or no gel• Require fewer electrodes• Are more portable• Handle artifacts better• Are wireless• Are cheaper
How do EEGs work?
Field recording systems from Quasar, Advanced Brain Monitoring, and Pineda et al (2003).
![Page 8: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/8.jpg)
8
QUASAR Hybrid or eIBE sensors
Audio Headset EOG/EEG GlassesQUASAR IBE Electrodes
How do EEGs work?
![Page 9: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/9.jpg)
9
Emotiv and NeuroSky systems
How do EEGs work?
![Page 10: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/10.jpg)
10
Invasive BCIs record activity from electrodes under the scalp.
Pyramidal neurons (Kandel et al., 1988)Electrocorticogram (ECoG) recording montage in a human patient. (Leuthardt et al., 2004)
How do EEGs work?
![Page 11: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/11.jpg)
11
Other functional imaging approaches:
• Functional Magnetic Resonance Imaging (fMRI)• Magnetoencephalography (MEG)• Positron Emission Tomography (PET)• Functional Near Infrared (fNIR)
How do EEGs work?
A functional MRI An MEG machine Functional Near Infrared
![Page 12: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/12.jpg)
12
BCIs cannot read minds or literally interpret mental activity.
helloyes
pain
What isn’t a BCI?
![Page 13: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/13.jpg)
13
BCIs are a popular topic in sci fi!
The Matrices Firefox Strange Days Neuromancer
JohnnyMnemonic
Star Trek: The Cage
Dreamscape The X – Mens
What isn’t a BCI?
![Page 14: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/14.jpg)
14
More bci fi ….
Total Recall Minority ReportBrainstorm The Lawnmower Men
The Govenator!!
What isn’t a BCI?
![Page 15: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/15.jpg)
15
BCIs cannot:
• Read your thoughts.
What isn’t a BCI?
![Page 16: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/16.jpg)
16
BCIs cannot:
• Operate without your knowledge or free will.
What isn’t a BCI?
![Page 17: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/17.jpg)
17
BCIs cannot:
• Write to the brain.
What isn’t a BCI?
![Page 18: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/18.jpg)
18
BCIs cannot:
• Repair injured areas.
What isn’t a BCI?
![Page 19: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/19.jpg)
19
These similar approaches are not BCIs:
• Biofeedback• Prosthetics• Retinal or cochlear implants• Medical EEGs• EEG or fMRI Lie Detection• Neuromarketing• Employee screening• Attention or fatigue monitors
What isn’t a BCI?
![Page 20: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/20.jpg)
20
BCIs rely on voluntary mental activities such as:
Imagined movement
What is a BCI?
Torrey Pines golf course
![Page 21: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/21.jpg)
21
BCIs rely on voluntary mental activities such as:
Emotional imagery
What is a BCI?
![Page 22: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/22.jpg)
22
BCIs rely on voluntary mental activities such as:
Selective attention(SSVEP)
What is a BCI?
![Page 23: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/23.jpg)
23
BCIs rely on voluntary mental activities such as:
Selective attention(P300)
What is a BCI?
![Page 24: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/24.jpg)
24
BCIs rely on voluntary mental activities such as:
Certain mental tasks6
X 942
Object rotation Math Singing
What is a BCI?
![Page 25: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/25.jpg)
25
What is a BCI?
![Page 26: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/26.jpg)
26
How do BCIs work?
o General Schematico P300 BCIo Mu BCIo Other BCIs
Components
![Page 27: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/27.jpg)
27
A BCI requires the following:
- At least 2 electrodes - An amplifier designed for EEGs- A mediocre personal computer- An A/D card in the computer- Software
Components
![Page 28: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/28.jpg)
28
All BCIs have at least four components:
1) Signal Acquisition
2) Feature Extraction
3) Translation Algorithm
4) Operating Environment
Components
The Four BCI Components(Wolpaw et al., 2002; Allison et al., 2007)
![Page 29: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/29.jpg)
29
Acquisition: The user performs a task that produces a distinct EEG signature for that BCI
Extraction: Salient features are extracted from the EEG
Translation: A pattern classification system uses these EEG features to determine which task the user performed
Environment: The BCI presents feedback to the user, and forms a message or command
Components
![Page 30: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/30.jpg)
30
Motor imagery: ERD
![Page 31: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/31.jpg)
31
Many sources create noise.
Electrode cap Raw EEGs from a field setting
Acquisition
![Page 32: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/32.jpg)
32
Acquisition
A headband used for a 1D mu BCI (Pineda et al., 2003) Several brain areas responsible for movement.
![Page 33: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/33.jpg)
33
EnvironmentUser task:
Imagine movement to move the cursor down.
Relax to move it up.
A mu BCI using BCI2000 (Schalk et al., 2004)
![Page 34: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/34.jpg)
34
Extraction, Translation
Mu activity used for one dimensional control (Wolpaw et al., 1991)
![Page 35: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/35.jpg)
35
Virtual Navigation
![Page 36: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/36.jpg)
36
Recording from a neuron (Kandel et al., 1988) Top: Utah intracranial electrode arrayBottom: Cone electrode
Cortical Neurons
![Page 37: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/37.jpg)
37
A severely disabled subject controls a switch (Kennedy et al., 2004)
A patient with an implanted BCI (Cyberkinetics, Inc.)
Cortical Neurons
![Page 38: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/38.jpg)
38
Cortical Neurons
ECog activity in several human patients during hand or tongue movement (Miller, in press)
![Page 39: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/39.jpg)
39
The P300 only occurs after target flashes (Allison and Pineda, 2003).
Selective attention: P300
EEGs from a P300 BCI
-4
-2
0
2
4
6
0 100 200 300 400 500 600 700
time after flash begins (ms)vo
ltage
(uV)
NontargetsTargets
![Page 40: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/40.jpg)
40
EEGs from a P300 BCI
-4
-2
0
2
4
6
0 100 200 300 400 500 600 700
time after flash begins (ms)
volta
ge (u
V)
NontargetsTargets
The P300 only occurs after target flashes (Allison, 2003).It is often largest over site Cz or Pz (central or parietal areas).
Acquisition, Extraction
![Page 41: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/41.jpg)
41
K
Translation
Site Fz
-4-20
2468
1012
141618
0 50 100
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
Averaged data from a P300 BCI at the NextFest Expo (Allison, 2004)
![Page 42: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/42.jpg)
42
Selective attention: SSVEP
Herrmann et al, Exp. Brain Research 2001
![Page 43: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/43.jpg)
43
Steady state visual evoked potential (SSVEP) BCI (Kelly et al., 2005)
SSVEP
6 Hz 15 Hz
![Page 44: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/44.jpg)
44
6 Hz
15 HzA different SSVEP BCI (Allison et al., 2006)
SSVEP
![Page 45: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/45.jpg)
45
Data from an SSVEP BCI using 6 and 15 Hz checkerboxes (Allison et al., 2008)
SSVEP
![Page 46: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/46.jpg)
46
SSVEP – GT BrainLab
![Page 47: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/47.jpg)
47
SSVEP – IAT BremenSSVEP spelling system
13 14 15 16 17
![Page 48: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/48.jpg)
48
SSVEP – IAT Bremen
1
2
3
4
5
1 2 3 4 5
MATRIX RHOMBUS
![Page 49: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/49.jpg)
49
SSVEP – IAT Bremen
![Page 50: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/50.jpg)
50
0 5 10 15 20 250
1
2
0
1
2
Spec
tral
den
sity
5 Hz
10 Hz
a) Stimulation frequency: 5 Hz
0 5 10 15 20 250
1
2
0
1
2
Spec
tral
den
sity
7 Hz14 Hz
b) Stimulation frequency: 7 Hz
0 5 10 15 20 250
1
2
0
1
2
Frequency (Hz)
Spec
tral
den
sity 9 Hz
18 Hz
c) Stimulation frequency: 9 Hz
SSVEP – IAT Bremen
![Page 51: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/51.jpg)
51
Row-Column layout- 44 commands -
Rhombus layout- 58 commands -
Average Average
3:40 4:25
99 %
30.6
98 %
28.4
Best Best
Time [min] 2:27 3:01
100 %
43
Accuracy 100 %
Bits/min 40
Nine subjects spelled
‘BRAIN COMPUTER INTERFACE.’
SSVEP – IAT Bremen
![Page 52: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/52.jpg)
52
SSVEP – IAT Bremen
![Page 53: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/53.jpg)
53
SSVEP – IAT Bremen
![Page 54: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/54.jpg)
54
SSVEP – IAT Bremen
![Page 55: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/55.jpg)
55
•Information throughput •BCI record = 9 char/min•Typing record = 750 char/min
•User needs, preferences, and abilities•Vocabulary and customizability•Equipment required
•cost•portability•invasiveness•support availability•appearance
•Task demands, ease of use and “distraction quotient”•Training time and parameters•Noise resistance
Comparing BCIs
![Page 56: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/56.jpg)
56
“Future progress hinges on … recognition that BCI development is an interdisciplinary problem, involving neurobiology, psychology, engineering, mathematics, computer science, and clinical rehabilitation…” – Wolpaw et al., 2002.
Communications, linguistics, HCI, and human factors are also important.
Future directions
![Page 57: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/57.jpg)
57
Replacing conventional interfaces for conventional users in conventional settings.
Stupid future directions
The future of BCIs is not Keanu Reeves.
![Page 58: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/58.jpg)
58
New user groups
Less disabled usersRehabilitation: stroke, autism, attentionHealthy users
GamersSurgeons, drivers, soldiers, mechanicsLazy people
Future directions
![Page 59: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/59.jpg)
59
Replacing conventional interfaces for disabledusers in conventional settings.
Replacing conventional interfaces for conventional users in specific environments.
Supplementing conventional interfaces.
Future directions
![Page 60: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/60.jpg)
60
Why supplement conventional interfaces?More bandwidthCognitive overloadPrivacyConvey otherwise unavailable informationNovelty, coolness, and public perception
Future directions
Plantronics gamer headset. Headset with dry electrodes.
![Page 61: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/61.jpg)
61
Game applications
Future directions
![Page 62: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/62.jpg)
62
Future directions
![Page 63: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/63.jpg)
63
Thanks to Chris Agocs, Jacqueline Boccanfuso, Ben Chi, Adriane Davis, Umang Dua, Bernhard Graimann, Axel Graeser, David Leland, ThorstenLueth, Luke McCampbell, Dennis McFarland, Melody Moore Jackson, Jaime Pineda, John Polich, Samir Ramji, Gerv Schalk, and Diana Valbuena for help with work presented here.
Thanks to my colleagues in the BCI community!
Attendees of the BCI conference in New York
Acknowledgements
![Page 64: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/64.jpg)
64
www.bci-info.org
http://www.cis.gsu.edu/brainlab/bci.ucsd.eduwww.cyberkineticsinc.comwww.neuralsignals.com
Additional videos are available from the Wolpaw lab: www.bciresearch.org
More videos from the Pfurtscheller lab:http://bci.tugraz.at/movies.html
Other sites are easy to find online. Please contact the author for specific references for articles or other materials:
Websites with more info
![Page 65: BZA BCI Projects - uni-bremen.de · Conventional electrode caps from EGI, Neuroscan, and Electro-Cap. 7 Newer EEG recording systems: • Require less or no prep time and skill](https://reader036.vdocuments.mx/reader036/viewer/2022070107/60223980dd3d4120a0164a70/html5/thumbnails/65.jpg)
65