SEWAGE & STROM WATER DISPOSALWATER SUPPLY
By-:vvvvvv vvvAnshu Dadwal (Lecturer)v vvv
![Page 2: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/2.jpg)
THE BUILDING STACKS
OFFICE BUILDING STACK
Stacks are generally large diameter CI pipes that carry wastewater collected from various locations in the buildings. There are two types of stacks, the old two stack system of two separate stacks, a pipe for wastewaters from water closets and another for all other sources, and the fully vented one stack system in which single pipe carries all wastes.They are also known as combined - and separate - system respectively. Most rainwater is conveyed directly to surface water drain in a variant called partially separate system.
![Page 3: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/3.jpg)
SINGLE STACK SYSTEM
![Page 4: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/4.jpg)
DOUBLE STACK SYSTEM• Also known as Two Pipe or Separate System
![Page 5: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/5.jpg)
PARTIALLY SEPARATE SYSTEM
![Page 6: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/6.jpg)
PARTIALLY – SEPARATE SYSTEM ACESSORIES
![Page 7: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/7.jpg)
PARTIALLY SEPARATE SYSTEM ACESSORIES
![Page 8: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/8.jpg)
PARTIALLY SEPARATE SYSTEM ACESSORIES
![Page 9: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/9.jpg)
PARTIALLY SEPARATE SYSTEM ACESSORIES
![Page 10: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/10.jpg)
THE NEGATIVE PRESSURE
Induced Siphonage. Discharge from one appliance creates a vacuum in another appliance’s branch pipe.Back Pressure. Excess pressure due to resistance at the base of a stack. large radius bends are therefore used.Self – Siphonage. Suction created as an appliance discharges into the stack.Negative pressure is created when total Bernoulli head downstream exceeds that upstream due to large pressure and/or velocity gradients.It damages the water seal of appliances and foul air enters the building.
![Page 11: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/11.jpg)
VENT FOR DRAINAGE
![Page 12: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/12.jpg)
VENT FOR DRAINAGE
![Page 13: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/13.jpg)
VENT FOR DRAINAGE
![Page 14: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/14.jpg)
SINGLE STACK DESIGNA stack coupled with a vent arrangement is needed in 3-5 storied buildings. Vents are not needed in low rise buildings. Above five stories the ground floor appliances are connected to a separate stack and vent system and others to a common system. Above twenty stories, both ground and first floor appliances are separately drained.
![Page 15: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/15.jpg)
FULLY – VENTED SINGLE – STACK SYSTEMThe fully vented single stack system is used in
buildings where there are a large number of sanitary appliances in ranges, e.g. factories, schools, offices and hospitals.The trap on each appliances is fitted with the anti-siphon or vent pipe. Individual vent pipes combine in a common vent in a range, which is inclined until it meets the vertical vent stack. The vent stack may be left open to atmosphere or it may connect to the main stack at a point above the spillover level of the highest appliance. The bottom of vent stack is connected to the main stack close to the bottom rest bend to relieve any compression at this point. Diameter of vent = half the diameter of main stack above 100mm dia; Two third for 50mm dia.
![Page 16: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/16.jpg)
VENT TOP DETAILS
AIR ADMITTANCE VALVE
![Page 17: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/17.jpg)
DRAINAGE IN BASEMENTS
![Page 18: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/18.jpg)
DRAIN SEWER CONNECTION
![Page 19: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/19.jpg)
DRAIN SEWER CONNECTION
![Page 20: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/20.jpg)
DOMESTIC SEWAGE DISPOSAL
![Page 21: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/21.jpg)
DOMESTIC SEWAGE DISPOSAL
![Page 22: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/22.jpg)
SEPTIC TANK DESIGN
No. of Users Length, m Breadth, m Liquid Depth, m 5 1.5 0.75 1.0 10 2.0 0.90 1.0 15 2.0 0.90 1.3 20 2.3 1.10 1.3 50 5.0 2.0 1.0 100 7.5 2.65 1.0 150 10.0 3.0 1.0 200 12.0 3.3 1.0 300 15.0 4.0 1.0
Free Board = 300 mm
Two compartments of 2:1 volume ratio are preferred.
![Page 23: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/23.jpg)
MUNICIPAL SEWAGE DISPOSAL
![Page 24: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/24.jpg)
RAIN WATER HARVESTING
![Page 25: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/25.jpg)
![Page 26: Building Drainage System](https://reader033.vdocuments.mx/reader033/viewer/2022061501/55cf9c57550346d033a97df3/html5/thumbnails/26.jpg)
THANK YOU.
•