5 C40 100 TO 2000 LITRES
Range from 100 Lt up to 2.000 Lt inertia tanks for primary circuits, manufactured
in F18 Stainless Steel.
Only to be used in heating circuits
Exterior finish in white polyester reinforced with fiberglass, which allows easy
cleaning and ensures its durability.
Coballes accumulators and tanks are manufactured according ecodesign Directive
ErP, (Energy related Products), using a quality injected polyurethane foam CFC
free.
Buffer Tank for heatin/HVAC systems
BUFFER TANK FOR HEATING CIRCUIT/ HVAC C40
Solar Firewood, pellets Gasoil/Gas
![Page 2: Buffer Tank for heatin/HVAC systems](https://reader030.vdocuments.mx/reader030/viewer/2022012416/6171855d4cb66e390a41a1fe/html5/thumbnails/2.jpg)
6
MODEL REF. LT INSTALL WALL
MOUNT
S.STEEL
LEG
FLOOR
STAND
ELECTRICAL
KIT
C40
1050060 100 Vertical yes - yes
1050061 150 Vertical yes - yes
1050062 200 Vertical yes - yes
1050063 300 Vertical - - yes
1050064 500 Vertical - - yes
1050065 750 Vertical - yes -
1050066 1000 Vertical - yes -
1050067 1500 Vertical - yes -
1050068 2000 Vertical - yes -
BUFFER TANK FOR HEATING CIRCUIT/ HVAC C40
To be used ONLY in heating circuits.
Maximum working pressure 4 bar.
Up to 200Lt the same model is valid wall mount and floor stand.
Coballes resistance Ref: 800237/800238
OPTIONAL ACCESORIES
![Page 3: Buffer Tank for heatin/HVAC systems](https://reader030.vdocuments.mx/reader030/viewer/2022012416/6171855d4cb66e390a41a1fe/html5/thumbnails/3.jpg)
7
Buffer tank for heating circuits C40
Suitable to storage hot water produced with multiple enrgy sources (heat pumps, Pellet, gas boilers...)
through an external heat exchanger.
Operating pressure 4 bar both primary and secondary circuit T: 90ºC both primary and
secundary circuit.
Manufacturing and materials 100% European
Manufactured according to Directive 2014/68/UE and Standard EN13445
Manufactured according to Directives ErP 2009/125 CE and ELD 2010/30/UE
BUFFER TANK FOR HEATING CIRCUIT/ HVAC C40
PICKLING
P i c k l i n g a n d
p a s s i v a t i o n b y
immersion which
allows a perfect
treatment of the
welds on the tank in
the face both internal
and external.
F18 STAINLESS STEEL
Manufactured in F18
Stainless Steel.
TIG WELDING
The highest accuracy in
welding, to avoid the
presence of pores.
KEY FEATURES
MAINTENANCE FREE
The high quality of
material we use does not
require any maintenance.
It does not need any type
of cathode protection.
ISOLATION
Thermal insulation in
polyurethane foam injected
C F C - f r e e , e n s u r i n g
compliance with the new
ERP Directive.
![Page 4: Buffer Tank for heatin/HVAC systems](https://reader030.vdocuments.mx/reader030/viewer/2022012416/6171855d4cb66e390a41a1fe/html5/thumbnails/4.jpg)
8
MODEL REFERENCE Energy class LT Dimensions (mm)
A ØB C D E
C40
1050060 C 100 430 740 1160 I
1050061 C 150 530 740 1245 I
1050062 C 200 600 740 1300 I
1050063 C 300 600 1830 II
1050064 C 500 750 1880 II
1050065 750 1740 980 110 1850 III
1050066 1000 2190 980 110 2300 III
1050067 1500 2490 1110 110 2600 III
1050068 2000 2290 1360 110 2400 III
Energetic class A avaliable. Request info
I
Dimensions
II III
![Page 5: Buffer Tank for heatin/HVAC systems](https://reader030.vdocuments.mx/reader030/viewer/2022012416/6171855d4cb66e390a41a1fe/html5/thumbnails/5.jpg)
9
MOD REF LT Connections
1 2 3 4 5 6 7 8 9 10 11 12
C40
1050060 100 1/2" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1/2"
1050061 150 1/2" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1/2"
1050062 200 1/2" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1/2"
1050063 300 1/2" 1 1/4" 1 1/4" 1" 1" 1 1/4" 1 1/4" 1/2" 2"
1050064 500 1/2" 1 1/2" 1 1/2" 1" 1" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1/2" 2" 3/4"
1050065 750 1/2" 1 1/2" 1 1/2" 1" 1" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1/2" 2" 1"
1050066 1000 1/2" 1 1/2" 1 1/2" 1" 1" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1/2" 2" 1"
1050067 1500 1/2" 2" 2" 1" 1" 2" 2" 2" 2" 1/2" 2" 1"
1050068 2000 1/2" 2" 2" 1" 1" 2" 2" 2" 2" 1/2" 2" 1"
Connections
1.-Purger
2.-Outlet (energy source) I
3.-Ida (energy source) I
4. Inlet solar panel (external heat exchanger) II
5.-Outlet solar panel(external heat exchanger) II
6.-Inlet (heating circuit) I
7.-Outlet (heating circuit) I
8.-Inlet (heating circuit) II
9.-Outlet (heating circuit) II
10.-Temp connection
11.-Resistance connection
12.-Drain
![Page 6: Buffer Tank for heatin/HVAC systems](https://reader030.vdocuments.mx/reader030/viewer/2022012416/6171855d4cb66e390a41a1fe/html5/thumbnails/6.jpg)
10
WARM-UP TIME
Tank1
Supplied energy (KW)
C40-100L C40-150L C40-200L C40-300L C40-500L C40-750L C40-1000L C40-1500L C40-2000L
5 min 70 105
10 min 35 52 70 105
15 min 23 35 46 70 116
25 min 21 28 42 70 105
35 min 20 30 50 75 100
50 min 21 35 52 70 105
75 min 23 35 46 70 93
100 min 26 35 52 70
150 min 23 35 46
200 min 26 35
1-Initial temperature 10ºC ; Final Temperatura 60ºC
Thermal characteristics
1kW=860kcal/hour
Tank Total
volume
Heating coil
surface
Maximum
pressure
(tank)
Maximum
operating
temperature
Net weight Energy
class
L m2 bar ºC Kg
C40-100L 100 − 4 90 23 C
C40-150L 150 − 4 90 34 C
C40-200L 200 − 4 90 43 C
C40-300L 300 − 4 90 57 C
C40-500L 500 − 4 90 90 C
C40-750L 750 − 4 90 120
C40-1000L 1000 − 4 90 147
C40-1500L 1500 − 4 90 187
C40-2000L 2000 4 90 413
![Page 7: Buffer Tank for heatin/HVAC systems](https://reader030.vdocuments.mx/reader030/viewer/2022012416/6171855d4cb66e390a41a1fe/html5/thumbnails/7.jpg)
11
MODEL D20 para INSTALL horizontal con panel solar
Installation examples
Model C40 may be installed with different energy sources
Gasoil/Gas Solar Electricity Heat Pump Firewood, pellets Others
To be used ONLY in heating circuits