bu power generation, abb switzerland ltd procontrol p13/42 … · 2018-05-10 · connection to p13...

19
Procontrol P13/42 Progress 3: Tool Upgrade Overview BU Power Generation, ABB Switzerland Ltd

Upload: others

Post on 14-Feb-2020

22 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Procontrol P13/42 Progress 3: Tool Upgrade Overview

BU Power Generation, ABB Switzerland Ltd

Page 2: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Former engineering and maintenance tools

BusAdmin

Progress 2

SK06 (and more)

are now combined into one Tool with one

Database.

Runs on normal Windows PC or Notebook.

Introduction: One P13 Tool fits All Progress 3: Tool Upgrade Overview

Page 3: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Menu for Hardware Definition & Signals Progress 3: Tool Upgrade Overview

Page 4: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

HEX-Editor Progress 3: Tool Upgrade Overview

online

values

Page 5: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Function Chart Editor Progress 3: Tool Upgrade Overview

Page 6: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Loading and PR05 Status Progress 3: Tool Upgrade Overview

Page 7: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Debugger & Simulation of Signals Progress 3: Tool Upgrade Overview

Page 8: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Direct Simulation of Bus Signals Progress 3: Tool Upgrade Overview

Page 9: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Test Set (Display, Record, Simulate) Progress 3: Tool Upgrade Overview

Page 10: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Code can be read from either RAM, EEPROM or even from Kombi EPROM

Online (Read code back from 70PR0x or 70ASx) Progress 3: Tool Upgrade Overview

Page 11: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Connection to P13 boards by use of

connector (direct local connection)

SK60 built in a Desktop PC (ISA SLOT)

SK61 external box for a Notebook PC

(USB 1.1)

SK62 external box for a Notebook PC

(USB 2.0)

Connection to Control System: SK60/61/62 Progress 3: Tool Upgrade Overview

7

0

S

S

0

1

7

0

S

P

0

2

Procontrol P13 local bus with 70PR03 and PR05

Connected by the use of simulation memory

70SS01 and test memory 70SP02 Setup in Progress 3

Applicable for:

70PR02

70PR03

70PR05

70BK02

70FV01

all 70ASxx

Page 12: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Connection to P13 boards from local bus

(70BK03) to serial interface (PC)

Variants:

70BK03c-E/R1 RS232 connection

70BK03c-E/R3 RS485 connection

Connection to Control System: 70BK03 Progress 3: Tool Upgrade Overview

Procontrol P13 local bus with 70PR03, 70PR05 and 70BK02

Simultaneous access to all local addresses resp. boards (local bus) possible

Setup in Progress 3 Direct serial connection (PC)

Identification of the boards by „code switch“

Applicable for:

70PR02

70PR03

70PR05

70BK02

70FV01

all 70ASxx

Page 13: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Connect to several local P13 stations

Serial connection (PC) or „remote“ by TCP/IP RS232 converter

Connection to Control System: 70BK03 Progress 3: Tool Upgrade Overview

RS232

TCP/IP

RS485

RS232

Applicable for:

70PR02

70PR03

70PR05

70BK02

70FV01

all 70ASxx

Page 14: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Connect to several local P13 stations

Local or remote connection by TCP/IP with new 70BI01 Device

Connection to Control System: 70BK03 & 70BI01 Progress 3: Tool Upgrade Overview

Applicable for:

70PR02

70PR03

70PR05

70BK02

70FV01

all 70ASxx

Page 15: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Connect to several local P13 stations via P42 intra-plant bus

Serial connection (PC) or „remote“ by TCP/IP RS232 converter

Connection to Control System: 70BK03 Progress 3: Tool Upgrade Overview

RS232

TCP/IP

Applicable for:

70PR02

70PR03

70PR05

70BK02

70FV01

all 70ASxx

Page 16: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Diagnosis by Progress 3 Tool for information Progress 3: Tool Upgrade Overview

© ABB Group

June 22, 2012 | Slide 16

Block 5 Block 6

Plant Network

2 x BK03

RS485

ST34-control

TCP/IP

RS 485

TCP/IP

RS 485

Prot CH1

TT control

Prot CH2

2 x BK03

RS485

ST44-control

Prot CH1

TT control

Prot CH2

Remote

Engineering &

Monitoring

Diagnosis of the

Control systems

Page 17: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Plant Maintenance Level

• Detailed graphical diagnostic displays

• Display diagnostic messages

• Display analog and digital values

• Trend display analog values

• Debugging functionality

Plant Diagnostics Level

• Plant-wide diagnostic alarm overview

• Detailed diagnostic displays

• Acknowledge diagnostic alarms

Diagnosis by Progress 3 Tool for information Progress 3: Tool Upgrade Overview

© ABB Group

June 22, 2012 | Slide 17

Module 70AA01 Fault Annunciation SME1 Module 70EA04 Fault Annunciation SME1

Page 18: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC
Page 19: BU Power Generation, ABB Switzerland Ltd Procontrol P13/42 … · 2018-05-10 · Connection to P13 boards by use of connector (direct local connection) SK60 built in a Desktop PC

Revision Index

Rev. Description Date / Dept.

- Initial release for external distribution 2012-06-19 / PSP-PRU

Progress 3: Tool Upgrade Overview

Document: 2VAA002154_en_Progress 3 Overview Presentation