b/s/h/ test program / coding instruction plc · - aqua stop solenoid valve is broken - pressure...
TRANSCRIPT
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 1 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Table Of Contents
1 FAULT CODES AND APPLIANCE MESSAGES ........................................................................ 3
1.1 FAULT CODES (IN ASCENDING ORDER) ...................................................................................... 3
16 ............................................................................................................................................ 3
23 ............................................................................................................................................ 4
31 ............................................................................................................................................ 5
47 ............................................................................................................................................ 6
57 ............................................................................................................................................ 7
63 ............................................................................................................................................ 8
78 ............................................................................................................................................ 9
2 SERVICE PROGRAMS ....................................................................................................... 10
2.1 CUSTOMER SERVICE TEST PROGRAM ...................................................................................... 10
Activate test mode ............................................................................................................... 10
Select test program .............................................................................................................. 10
Start test program ................................................................................................................ 11
Abort test program ............................................................................................................... 11
Leave test mode ................................................................................................................... 11
3 FUNCTIONS OF SERVICE PROGRAMS ............................................................................... 12
3.1 CUSTOMER SERVICE TEST PROGRAM ...................................................................................... 12
P1: Stored error codes / Error search .................................................................................. 12 P2: Safety test ...................................................................................................................... 12
P3: Automatic test ............................................................................................................... 13
P4: Motor / 3D/3G sensor ................................................................................................... 14
P5: Variant coding ............................................................................................................... 15
P6: Display............................................................................................................................ 15
P7: Keys and program selector ............................................................................................ 16
P8: Water level (pressure sensor) ........................................................................................ 16
P9: Turbidity sensor (aqua sensor) ...................................................................................... 17
P10: Flow sensor .................................................................................................................. 18
P12: Load sensor .................................................................................................................. 18
P14: Valves ........................................................................................................................... 19
P15: Buzzer ........................................................................................................................... 20 P16: Pump ............................................................................................................................ 21
P17: Heater .......................................................................................................................... 21
4 VARIANT CODING ............................................................................................................ 22
4.1 VARIANT CODING .............................................................................................................. 22
Activate variant coding mode .............................................................................................. 22
Start variant coding mode .................................................................................................... 22
Select variant ........................................................................................................................ 22
Select variant code ............................................................................................................... 22
Save variant coding .............................................................................................................. 22
Setting speed variant (range 0...7) ..................................................................................... 23
Setting aqua stop / warm water variant (range 0...2) ....................................................... 23
Setting door lock variant (range 0...1) ................................................................................ 24
Setting flow sensor variant (range 0...2) ............................................................................ 24
Setting turbidity sensor (aqua sensor) variant (range 0...2) .............................................. 24
Setting VT-set variant (range 0...3) ..................................................................................... 25
Setting language cluster (range 0...7)................................................................................. 25
Setting language (range 0...7) ............................................................................................ 26
Setting brand (range 0...7) .................................................................................................. 27
Setting key variant (range 0) ............................................................................................... 27
Setting menu variant (range 0) ........................................................................................... 28
Setting load display variant (range 0...1) ........................................................................... 28
Setting child lock variant (range 0...1) ................................................................................ 28
Setting valve terminal (range 0...1) .................................................................................... 28
Setting control variant (range 0...4) ................................................................................... 29
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 2 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
EXPLANATION
Page navigation – Shows page 1
LED start/pause is off
Press key
LED start/pause is illuminating
Press key and keep pressed
LED start/pause is flashing
Leave key
Key start/pause
Rotate program selector
Key up
Pull mains plug
Key down
Put mains plug
Key plus
Key temperature down / up
Key minus
Key spin speed down / up
Program selector
S/P
S/P
S/P
S/P
>
-
>
>
<+
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 3 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
1 FAULT CODES AND APPLIANCE MESSAGES ① FATAL ERROR / ② REMANENT ERROR sequence:
a) washing program is aborted b) door is locked, if possible c) the pump removes water d) operator control actions are blocked e) the current indication is frozen
① Restart of washing program is possible by switching Off and On the appliance. ② Reset of error by switching Off and On the appliance is impossible. Error can be erased by activating the test mode. Ⓧ Malfunction is displayed during the washing program.
Display Description Possible cause Check / Remedial action / Remark F. No. Normal- Test mode Possible effect
1.1 Fault codes ( in ascending order )
16 Ⓧ Door open? F: 16 Door lock open - washing program is halted - a restart is possible - error will not be stored
- door is open - door switch is not actuated
- close door, check door lock, wire harness Normal mode: start any washing program with an open door
17 Ⓧ Tap closed?
F: 17 Water filling time exceeded (conventional measurement) - washing program is halted - pump starts after 5 min - a restart is possible
- water tap is closed - water pressure <1bar at supply - filter or supply is blocked - solenoid valve is broken - aqua stop solenoid valve is broken - pressure sensor is broken
- open water tap - check components, wire harness P8: Water level (pressure sensor) P14: Valves
18 Ⓧ Pump blocked?
F: 18 Pumping time exceeded - FATAL ERROR without c)
- pump is blocked or broken - pressure sensor is broken - hose to the pressure sensor is blocked - draining hose is blocked
- switch off and on for reset - check/clean components, check wire harness P16: Pump
19 F: 19 Heating time exceeded - washing program will be finished without heating
- heating circuit is broken - set temperature can not be achieved - low voltage - fossil heater or heater is broken - heater relay is blocked
- check heater, wire harness, control P17: Heater
20 F:20 Unexpected heating - FATAL ERROR
- NTC is broken (out of range) - heater relay is stuck - the heater is actuated in a non heating period
- switch off and on for reset - check NTC, heater, power module P17: Heater
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 4 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
① FATAL ERROR / ② REMANENT ERROR sequence:
a) washing program is aborted b) door is locked, if possible c) the pump removes water d) operator control actions are blocked e) the current indication is frozen
① Restart of washing program is possible by switching Off and On the appliance. ② Reset of error by switching Off and On the appliance is impossible. Error can be erased by activating the test mode. Ⓧ Malfunction is displayed during the washing program.
Display Description Possible cause Check / Remedial action / Remark F. No. Normal- Test mode Possible effect
23 Ⓧ F: 23 F: 23 Aqua stop actuated - washing program is aborted - the pump is actuated
- water in the base tub - leaky water system - aqua stop switch is blocked / broken
- check leak tightness of water system - check aqua stop switch, wire harness Normal mode
25 F: 25 Error of Aqua Sensor (Turbidity Sensor) (calibration of operating point failed) - washing program will be finished without rinsing cycles
- calcified Aqua Sensor (Turbidity Sensor) - check Aqua Sensor, wire harness P9: Turbidity sensor (aqua sensor)
26 F: 26 Error of analogue pressure sensor (provides error voltage) - FATAL ERROR
- pressure sensor broken - hose to the pressure sensor is blocked
- switch off and on for reset - check pressure sensor, hose to the pressure sensor, wire harness P8: Water level (pressure sensor)
27 F: 27 Error of offset adjustment of analogue pressure sensor - the adjustment will be skipped - the old value will be used
- pressure sensor is broken - check pressure sensor, wire harness P8: Water level (pressure sensor)
28 F: 28 Error of flow sensor (provides implausible values) - the water intake is changed from volume based to time based
- flow sensor is broken - check flow sensor, wire harness P10: Flow sensor
29 Ⓧ Tap closed?
F: 29 No water filling detected by flow sensor (fast measurement) - washing program is halted - pump starts after 5 min - a restart is possible
- water tap is closed - water pressure <1bar at supply - filter or supply is blocked - valves, aqua stop valve or flow sensor broken
- open water tap - check components, wire harness Normal mode P8: Water level (pressure sensor) P14: Valves
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 5 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
① FATAL ERROR / ② REMANENT ERROR sequence:
a) washing program is aborted b) door is locked, if possible c) the pump removes water d) operator control actions are blocked e) the current indication is frozen
① Restart of washing program is possible by switching Off and On the appliance. ② Reset of error by switching Off and On the appliance is impossible. Error can be erased by activating the test mode. Ⓧ Malfunction is displayed during the washing program.
Display Description Possible cause Check / Remedial action / Remark F. No. Normal- Test mode Possible effect
31 F: 31 Overflow level exceeded - water level is pumped down below overflow level - the program is continued
- pump is blocked - draining hose is blocked - solenoid valve is stuck - adjustment of pressure sensor is incorrect └ pressure sensor is blocked └ hose to the pressure sensor blocked
- check solenoid valve, pump, pressure sensor, hose to the pressure sensor, wire harness P8: Water level (pressure sensor) P14: Valves P16: Pump
32 F:32 Spinning interruption - spinning interruption
- unbalance detected - no need to take into consideration Normal mode
34 Ⓧ F: 34 F: 34 Door lock can not be locked - FATAL ERROR without b) and c) - door is unlocked, if possible
- door lock is broken - door hook, or door is stuck - stiff gasket
- switch off and on for reset - check door lock, mechanism, wire harness Normal mode
35 F: 35 Door lock can't be unlocked - FATAL ERROR with a) only - door stays locked - door is unlocked, if possible
- door lock is broken - door hook, or door is stuck - stiff gasket
- switch off and on for reset - check door lock, mechanism, wire harness Normal mode
36 Ⓧ F: 36 F: 36 Door lock circuit defect - FATAL ERROR without b) and c) - door is unlocked, if possible
- power unit is broken └ Triac is broken └ Relays is broken
- switch off and on for reset - check power unit, wire harness Normal mode
37 F: 37 Error of temperature sensor: break - washing program will be finished without heating
- NTC is broken - check NTC, wire harness P17: Heater
38 F: 38 Error of temperature sensor: short -circuit - washing program will be finished without heating
- NTC is broken - check NTC, wire harness P17: Heater
43 F:43 Drum motor is blocked (stored in error stack in normal mode only) - program will be finished with limited motor running
- blocked drum caused by laundry - motor is blocked
- switch off and on for reset - check laundry load, motor P4: Motor / 3D/3G sensor
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 6 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
① FATAL ERROR / ② REMANENT ERROR sequence:
a) washing program is aborted b) door is locked, if possible c) the pump removes water d) operator control actions are blocked e) the current indication is frozen
① Restart of washing program is possible by switching Off and On the appliance. ② Reset of error by switching Off and On the appliance is impossible. Error can be erased by activating the test mode. Ⓧ Malfunction is displayed during the washing program.
Display Description Possible cause Check / Remedial action / Remark F. No. Normal- Test mode Possible effect
47 F:47 Motor unit: defect temperature sensor - motor driving is interrupted and paused for 60s - motor driving is actuated again - if error remains, program is continued without motor
- temperature sensor at heat sink in motor unit is defect
- switch off, wait for 30s and switch on for reset - check motor unit P4: Motor / 3D/3G sensor
48 F:48 Motor unit: low voltage in intermediate circuit - motor driving is interrupted and paused for 60s - motor driving is actuated again - if error remains, program is continued without motor
- permanent undervoltage (below 99V) - wrong measurement of intermediate circuit voltage
- switch off, wait for 30s and switch on for reset - check voltage of power supply, motor unit P4: Motor / 3D/3G sensor
49 F:49 Motor unit: high voltage in intermediate circuit - motor driving is interrupted and paused for 60s - motor driving is actuated again - if error remains, program is continued without motor
- permanent overvoltage (above 295V) - wrong measurement of intermediate circuit voltage
- switch off, wait for 30s and switch on for reset - check voltage of power supply, motor unit P4: Motor / 3D/3G sensor
50 F:50 Error of current control (ASM) - motor driving is interrupted and paused for 30s - motor driving is actuated again - if error remains, program is continued without motor
- motor circuit defect - motor puley blocked - motor coil defect
- switch off, wait for 30s and switch on for reset - check motor, motor unit - replace motor, motor unit P4: Motor / 3D/3G sensor
51 F:51 Motor unit: short circuit of IGBT - motor driving is interrupted and paused for 60s - motor driving is actuated again - if error remains, program is continued without motor
- defect IGBT (power switches) in motorunit - switch off, wait for 30s and switch on for reset - check / replace motor unit P4: Motor / 3D/3G sensor
52 F:52 Motor unit: break of IGBT - motor driving is interrupted and paused for 60s - motor driving is actuated again - if error remains, program is continued without motor
- break of motor wiring - motor wires are not connected - IGBTs (power switches) are defect
- switch off, wait for 30s and switch on for reset - check wiring between motor and motor unit, motor unit P4: Motor / 3D/3G sensor
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 7 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
① FATAL ERROR / ② REMANENT ERROR sequence:
a) washing program is aborted b) door is locked, if possible c) the pump removes water d) operator control actions are blocked e) the current indication is frozen
① Restart of washing program is possible by switching Off and On the appliance. ② Reset of error by switching Off and On the appliance is impossible. Error can be erased by activating the test mode. Ⓧ Malfunction is displayed during the washing program.
Display Description Possible cause Check / Remedial action / Remark F. No. Normal- Test mode Possible effect
57 Ⓧ F: 57 F:57 Motor unit: communication error motor unit - FATAL ERROR
- motor unit, or power unit defect - D-Bus wire is not or wrong connected (wrong direction) - D-Bus wire has loose contacts - permanent noise produced by other communication partners (3D/3G sensor,operating unit)
- switch off, wait for 30s and switch on for reset - check D-Bus wiring, motor unit, power unit P4: Motor / 3D/3G sensor
58 F:58 Communication error 3D/3Gsensor - low spinning speed - wet clothes after spinning - no influence of washing program
- 3D/3G sensor is defect - 3D/3G sensor is not wired to power unit
- check 3D/3G sensor, D-Bus wiring P4: Motor / 3D/3G sensor
59 F: 59 3D/3G sensor: measurement error or plausibility error - reduced spinning speed
- 3D/3G sensor, or wire harness broken - magnet not in position - EMC failure - software of 3D/3G sensor is incompatible Only if above named reasons,could be excluded: - power unit is broken
- check 3D/3G sensor, wire harness, position of magnet - check EMC failure, check software Only if above named components are okay - check power unit P4: Motor / 3D/3G sensor
60 F: 60 Flow sensor: too low or too high values - water intake is changed from volume based to time based
- flow sensor is broken - turbulent water in the sensor or hose
- check flow sensor, filter in solenoid valve, wire harness P10: Flow sensor
61 F: 61 Implausible door lock status - FATAL ERROR
- door is locked but open - emergency unlock was actuated by hand
- switch off and on for reset - check door lock, mechanic, wire harness Normal mode
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 8 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
① FATAL ERROR / ② REMANENT ERROR sequence:
a) washing program is aborted b) door is locked, if possible c) the pump removes water d) operator control actions are blocked e) the current indication is frozen
① Restart of washing program is possible by switching Off and On the appliance. ② Reset of error by switching Off and On the appliance is impossible. Error can be erased by activating the test mode. Ⓧ Malfunction is displayed during the washing program.
Display Description Possible cause Check / Remedial action / Remark F. No. Normal- Test mode Possible effect
63 Ⓧ F: 63 F: 63 System error - FATAL ERROR without c)
- incorrect variant coding - no communication between power unit and operating unit
- switch off and on for reset - check variant coding in test mode, D-Bus wire harness, power unit Normal mode
67 Ⓧ F: 67 F: 67 Implausible or inexistent variant coding - FATAL ERROR
- variant code is incompatible between the controls - software of controls is incompatible
- switch off and on for reset - repeat variant coding - replace control(s) P5: Variant coding
71 F:71 Motor unit: inrush current lmiting resistor is not shorted by relay or no motor connected - motor driving is interrupted and paused for 60s - motor driving is actuated again - if error remains, program is continued without motor
- motor wire is defect or not connected - NTC-relay on motor unit is defect
- switch off, wait for 30s and switch on for reset - check wiring between motor and motor unit - check motor unit P4: Motor / 3D/3G sensor
72 F:72 Motor unit: shorted motor coil test - motor driving is interrupted and paused for 60s - motor driving is actuated again - if error remains, program is continued without motor
- motor wire is defect or not connected - motor has shortcut in windings
- switch off, wait for 30s and switch on for reset - check wiring between motor and motor unit - check motor unit P4: Motor / 3D/3G sensor
75 F:75 Motor unit: speed not reached - motor driving is interrupted and paused for 60s - motor driving is actuated again - if error remains, program is continued without motor
- friction or blocked drum - rough steering bearing - to high load of clothes - water ring in drum during spinning
- switch off, wait for 30s and switch on for reset - check easy moving of drum, laundry load, pump, motor unit, fluff filter - discharge pipe, fluff filter P4: Motor / 3D/3G sensor
77 F:77 Motor unit: line frequency out of range - motor driving is interrupted and paused for 30s - motor driving is actuated again - if error remains, program is continued without motor
- line frequency is out of range (35Hz..75Hz) for long time
- switch off, wait for 30s and switch on for reset - check frequency of power supply, motor unit P4: Motor / 3D/3G sensor
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 9 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
① FATAL ERROR / ② REMANENT ERROR sequence:
a) washing program is aborted b) door is locked, if possible c) the pump removes water d) operator control actions are blocked e) the current indication is frozen
① Restart of washing program is possible by switching Off and On the appliance. ② Reset of error by switching Off and On the appliance is impossible. Error can be erased by activating the test mode. Ⓧ Malfunction is displayed during the washing program.
Display Description Possible cause Check / Remedial action / Remark F. No. Normal- Test mode Possible effect 78 E:78 Motor unit: General hardware failure
- motor driving is interrupted and paused for 60s - motor driving is actuated again - if error remains, program is continued without motor
- current and voltage measurement channels are defect
- switch off, wait for 30s and switch on for reset - check motor unit P4: Motor / 3D/3G sensor
80 Ⓧ F:80 F:80 Power unit: relay for motor unit defect - FATAL ERROR
- relay on power unit for switching motor unit is defect - circuit for driving the relay is defect
- check power unit P4: Motor / 3D/3G sensor
82 F:82 Motor unit : temperature of cooling element of the inverter too high - motor driving is interrupted and paused for 30s - motor driving is actuated again - if the error remains, washing program is continued without motor
- friction or blocked drum - rough steering bearing - to high load of clothes - water ring in drum during spinning
- switch off, wait for 30s and switch on for reset - check easy moving of drum, laundry load, pump, motor unit, fluff filter - discharge pipe, fluff filter P4: Motor / 3D/3G sensor
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 10 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
2 SERVICE PROGRAMS Function Actuation Display Remark BO - Bosch SE – Siemens, RE – Regional brands
2.1 Customer service test program
Activate test mode
Close the door
Switch on appliance Wait until the LCD backlight is switched on
No error: No error:
Use ‘Options’ keys to...
Error: Errors last program
F: xx
- all REMANENT ERRORs are reset
Select test program
P1: Errors
inactive
Error stack P1: Stored error codes / Error search
P2: Safety
inactive
Safety test P2: Safety test
P3: Automatic
inactive
Automatic test P3: Automatic test
P4: Motor
inactive
Motor test P4: Motor / 3D/3G sensor
P5: Variantcoding
inactive
Variant coding Activate variant coding mode
P6: Display
inactive
Display test P6: Display
P7: Selector
inactive
Key and program selector test P7: Keys and program selector
Select test program
P8: Waterlevel
inactive
Pressure sensor test P8: Water level (pressure sensor)
h
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 11 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark BO - Bosch SE – Siemens, RE – Regional brands
(continuance)
P9: Aquasensor
inactive
Turbidity sensor (Aqua sensor) test P9: Turbidity sensor (aqua sensor)
P10: Flow sensor
inactive
Flow sensor test P10: Flow sensor
P11: 3D Sensor
inactive
3D sensor (please use P4: Motor / 3D/3G sensor test)
P12: Load sensor
inactive
Load sensor P12: Load sensor
P14: Valves
inactive
Valves P14: Valves
P15: Buzzer
inactive
Buzzer P15: Buzzer
P16: Pump
inactive
Pump P16: Pump
P17: Heater
inactive
Heater P17: Heater
Start test program
Abort test program
Leave test mode
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 12 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
3 FUNCTIONS OF SERVICE PROGRAMS Function Actuation Display Remark Time (s) Value Inspection / Corrective Note
3.1 Customer service test program P1: Stored error codes / Error search
Display of errors occured within the last finished program
No error:
P1: Errors
last program
no errors
Max. 8 finished programs and 5 errors per program are displayed
Error:
P1: Errors
last program
F23, 0, 0, 0, 0
Display of errors occured within the second to last program
P1: Errors
last program -1
F23, 0, 0, 0, 0
Display of errors occured within the third to last program
P1: Errors
last program -2
0, 0, 0, 0, 0
Display of errors occured within the fourth to last program
P1: Errors
last program -3
0, 0, 0, 0, 0
...
...
Display of errors occured within the eightth to last program
P1: Errors
last program -7
0, 0, 0, 0, 0
P2: Safety test
Door is locked
P2: Safety
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
There is no need of water intake or to switch on the heater. The heater test should be conducted before safety test is started. Therefore is secured that both heater fuses are working.
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 13 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Time (s) Value Inspection / Corrective Note
P2: Safety
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
15 - Wait
Pull out mains plug
Put mains plug into safety testing device
P2: Safety
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
- Door must be locked; - Program selector is NOT at position 0 (off)
Ground and leakage current Run the test program of the safety testing device
P2: Safety
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
Door is unlocked P2: Safety
D M P H V1 V2 V3 Nxxxx
... ... ... ... ... ... ...
P3: Automatic test
Door is locked
P3: Automatic
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
Temp. xx
Quick test of all components - Sequence see next page
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 14 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working
Function Actuation Display Remark Time (s) Value Inspection / Corrective Note
Door is unlocked
P3: Automatic
D M P H V1 V2 V3 Nxxxx
... ... ... ... ... ... ...
P4: Motor / 3D/3G sensor
Door is locked
P4: Motor
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
- Unbalance detection is disabled - catastrophe limit unbalance detection is enabled
Pump is activated P4: Motor
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
4
9
4
4
11
12
3
5
4
15
9
7
3
8
5
7
7
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28
Pump
Heater
Valve 3 - warm water
Valve 2 - main wash
Valve 1 - pre wash
LEDs and display
Motor right rotation
Motor left rotation
Valve - aqua stop
Door lock
Time in s40s at1000 rpm
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 15 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Time (s) Value Inspection / Corrective Note
Motor is activated (drum rotation anti clockwise)
P4: Motor
D M P H V1 V2 V3 Nxxxx
= < = ... ... ... ...
aim. xxxx now xxxx
8 50rpm Actual- and target spin speed are displayed (now xxxx and aim xxxx)
Pause P4: Motor
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
2
Motor is activated (drum rotation clockwise)
P4: Motor
D M P H V1 V2 V3 Nxxxx
= > = ... ... ... ...
aim. xxxx now xxxx
2 50rpm Actual- and target spin speed are displayed (now xxxx and aim xxxx)
Spin speed is increased to maximum spin speed (drum rotation anti clockwise)
P4: Motor
D M P H V1 V2 V3 Nxxxx
= < = ... ... ... ...
aim. xxxx now xxxx
Actual- and target spin speed are displayed (now xxxx and aim xxxx)
Spinning with maximum spin speed
P4: Motor
D M P H V1 V2 V3 Nxxxx
= < = ... ... ... ...
aim. xxxx now xxxx
3 min max. rpm
Actual spin speed = target spin speed (now xxxx = aim xxxx)
Pump and motor are switched off
P4: Motor
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
Door is unlocked P4: Motor
D M P H V1 V2 V3 Nxxxx
... ... ... ... ... ... ...
P5: Variant coding
See chapter 4 Variant coding
P6: Display
Door stays unlocked
P6: Display
D M P H V1 V2 V3 Nxxxx
... ... ... ... ... ... ...
LCD segments, LCD backlight and the S/P key are switched off
1
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 16 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Time (s) Value Inspection / Corrective Note
S/P key is switched on 1
S/P key is switched off 1
LCD backlight is switched on
Chequer board pattern in the LCD text area is displayed
5
Chequer board pattern is inverted
5
All display segments are switched on
5
Each display segment is switched on separately
0,3 each
LCD backlight is switched off/on (interval 1s)
5
P7: Keys and program selector
Door stays unlocked P7: Selector
<key name>
Prog. xx
The actuated key name and program selector position are displayed
P7: Selector
<key name>
Prog. xx
- Do not rotate the program selector via off position
P8: Water level (pressure sensor)
Door is locked P8: Waterlevel
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 17 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Time (s) Value Inspection / Corrective Note
Pump is activated until the appliance is completely drained
P8: Waterlevel
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
ini. xxxx
stored value is displayed (ini. xxxx)
Adjustment of pressure sensor started
P8: Waterlevel
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
Adjustment of pressure sensor ended
P8: Waterlevel
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
Pump is switched off and water is taken in via V1
P8: Waterlevel
D M P H V1 V2 V3 N1660
= ... ... ... = ... ...
ini. xxxx
ca. 2 - 4cm
above drum bottom (level ~1660)
Door is unlocked P8: Waterlevel
D M P H V1 V2 V3 N1660
... ... ... ... ... ... ...
P9: Turbidity sensor (aqua sensor)
Door is locked P9: Aquasensor
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
Pump is activated until the appliance is completely drained
P9: Aquasensor
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
aqua xxx
Adjustment of aqua sensor started
P9: Aquasensor
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
aqua xxx
Adjustment of aqua sensor ended
P9: Aquasensor
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
aqua xxx
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 18 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Time (s) Value Inspection / Corrective Note
Pump is switched off P9: Aquasensor
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
aqua xxx
stored value is displayed (aqua xxx)
Door is unlocked P9: Aquasensor
D M P H V1 V2 V3 Nxxxx
... ... ... ... ... ... ...
10
P10: Flow sensor
Door is locked P10: Flow sensor
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
Pump is activated until the appliance is completely drained
P10: Flow sensor
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
vol. x flow xx
Pump is switched off and water is taken in via V1
P10: Flow sensor
D M P H V1 V2 V3 Nxxxx
= ... ... ... = ... ...
vol. 5 flow 7...10
approx. 5l
drum is visible covered with water
- Tolerance depends on water supply pressure
Door is unlocked P10: Flow sensor
D M P H V1 V2 V3 Nxxxx
... ... ... ... ... ... ...
10
P12: Load sensor
Door is locked P12: Load sensor
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
Initialisation P12: Load sensor
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
vol. 0 load 0
3
Water is taken in via V1 P12: Load sensor
D M P H V1 V2 V3 Nxxxx
= ... ... ... = ... ...
vol. 2 load 200
2l Actual load is displayed (appr. 100...300)
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 19 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Time (s) Value Inspection / Corrective Note
Pause P12: Load sensor
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
10
Water is taken in via V1 P12: Load sensor
D M P H V1 V2 V3 Nxxxx
= ... ... ... = ... ...
vol. 4 load 400
2l Actual load is displayed (appr. 300...500)
Pause P12: Load sensor
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
10
Water is taken in via V1 P12: Load sensor
D M P H V1 V2 V3 Nxxxx
= ... ... ... = ... ...
vol. 6 load 600
2l Actual load is displayed (appr. 500...700)
Pause P12: Load sensor
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
10
Pump is activated until the appliance is completely drained
P12: Load sensor
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
vol. 0 load 0
Door is unlocked P12: Load sensor
D M P H V1 V2 V3 Nxxxx
... ... ... ... ... ... ...
10
P14: Valves
Door is locked P14: Valves
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
Pump is activated until the appliance is completely drained
P14: Valves
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
vol. 0
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 20 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Time (s) Value Inspection / Corrective Note
Pump is switched off P14: Valves
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
Water is taken in via V1 P14: Valves
D M P H V1 V2 V3 Nxxxx
= ... ... ... = ... ...
vol. xx
5
Water is taken in via V2 P14: Valves
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... = ...
vol. xx
5 - for cold water appliances only, otherwise 5 s break
Water is taken in via V3 P14: Valves
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... =
vol. xx
5 - for warm water appliances only, otherwise 5 s break
Water is taken in via V1 and V2 until overflow level is reached
P14: Valves
D M P H V1 V2 V3 Nxxxx
= ... ... ... = = ...
vol. xx
- for cold water appliances only, otherwise 5 s break
Pump is activated P14: Valves
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
90 Error F: 31 is displayed
Door is unlocked P14: Valves
D M P H V1 V2 V3 Nxxxx
... ... ... ... ... ... ...
P15: Buzzer
Door stays unlocked P15: Buzzer
D M P H V1 V2 V3 Nxxxx
... ... ... ... ... ... ...
Buzzer is switched on with maximum volume
P15: Buzzer
D M P H V1 V2 V3 Nxxxx
... ... ... ... ... ... ...
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 21 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Time (s) Value Inspection / Corrective Note
P16: Pump
Door is locked P16: Pump
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
Pump is activated P16: Pump
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
Pump is switched off P16: Pump
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
Break P16: Pump
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
2
Pump is activated P16: Pump
D M P H V1 V2 V3 Nxxxx
= ... = ... ... ... ...
2
Door is unlocked P16: Pump
D M P H V1 V2 V3 Nxxxx
... ... ... ... ... ... ...
P17: Heater
Door is locked P17: Heater
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
Water is taken in via V1 until heater level is reached
P17: Heater
D M P H V1 V2 V3 Nxxxx
= ... ... ... = ... ...
level N ~ 1660
Heater is activated P17: Heater
D M P H V1 V2 V3 Nxxxx
= ... ... = ... ... ...
Temp. xx
max. 30min
85°C
Door stays locked P16: Pump
D M P H V1 V2 V3 Nxxxx
= ... ... ... ... ... ...
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 22 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
4 VARIANT CODING The customer service code is displayed: - at a label on the inner door surface - at the rating plate at the rear panel of the appliance Func tion Actuation Display Remark BO - Bosch SE, RE – Siemens, ...
4.1 Variant coding
Activate variant coding mode Select P5: Variantcoding in test mode P5: Variantcoding
inactive
Select test program
Start variant coding mode P5: Variantcoding
Speed
xx
Act. selected variant and variant code is displayed
Select variant
P5: Variantcoding
<xxxx>
xx
Select variant code P5: Variantcoding
xxxx
<xx>
Save variant coding Appliance will be switched off and on again (in normal mode)
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 23 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Serial PCB Customer service PCB
Setting speed variant (range 0...7) All information regarding the oscillating system is printed at the top weight
Variant 0 P5: Variantcoding
Speed
0
1600 rpm Oscillating system 1600
Variant 1 P5: Variantcoding
Speed
1
1400 rpm Oscillating system 1600
Variant 2 P5: Variantcoding
Speed
2
1200 rpm Oscillating system 1600
Variant 3 P5: Variantcoding
Speed
3
1000 rpm Oscillating system 1400 / 1600
Variant 4 P5: Variantcoding
Speed
4
1400 rpm Oscillating system 1400
Variant 5 P5: Variantcoding
Speed
5
1200 rpm Oscillating system 1400
Variant 6 P5: Variantcoding
Speed
6
1200 rpm Oscillating system 1200
Variant 7 P5: Variantcoding
Speed
7
1000 rpm Oscillating system 1200
Setting aqua stop / warm water variant (range 0...2 )
Variant 0 P5: Variantcoding
Aquastop / WW
0
Cold water with aqua stop
Variant 1 P5: Variantcoding
Aquastop / WW
1
Warm water without aqua stop
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 24 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Serial PCB Customer service PCB
Variant 2 P5: Variantcoding
Aquastop / WW
2
Cold water without aqua stop
Setting door lock variant (range 0...1)
Variant 0 P5: Variantcoding
Door Fastening
0
PTC door lock
Variant 1 P5: Variantcoding
Door Fastening
1
Magnetic door lock
Setting flow sensor variant (range 0...2)
Variant 0 P5: Variantcoding
Flow Sensor
0
Without flow sensor
Variant 1 P5: Variantcoding
Flow Sensor
1
With flow sensor
Variant 2 P5: Variantcoding
Flow Sensor
2
With flow sensor in cold and hot water inlet
Setting turbidity sensor (aqua sensor) variant (ran ge 0...2)
Variant 0 P5: Variantcoding
Turbidity Sensor
0
Without turbidity sensor
Variant 1 P5: Variantcoding
Turbidity Sensor
1
With turbidity sensor
Variant 2 P5: Variantcoding
Turbidity Sensor
2
Not used
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 25 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Serial PCB Customer service PCB
Setting VT-set variant (range 0...3)
Variant 0 P5: Variantcoding
VT-Set
0
X (not changeable) X Lookup control designation (MExxxx) on rating plate or door label. Lookup coding on document “spare part information”
Variant 1 P5: Variantcoding
VT-Set
1
Not used X Lookup control designation (MExxxx) on rating plate or door label. Lookup coding on document “spare part information”
Variant 2 P5: Variantcoding
VT-Set
2
Not used X Lookup control designation (MExxxx) on rating plate or door label. Lookup coding on document “spare part information”
Variant 3 P5: Variantcoding
VT-Set
3
Not used X Lookup control designation (MExxxx) on rating plate or door label. Lookup coding on document “spare part information”
Setting language cluster (range 0...7) BO / SE / RE Gaggenau
Variant 0 P5: Variantcoding
Language-Cluster
0
Language cluster 0 (not changeable) (German, Italian, French, Dutch, English EU, Turkish)
Language cluster 0 (German, Italian, French, Dutch, English EU, Turkish)
Language cluster 0 (English UK, Spanish, French, Turkish, German, Russian)
Variant 1 P5: Variantcoding
Language-Cluster
1
Not used Language cluster 1 (Czech, Hungarian, English EU, German, Slovenian, Not used)
Language cluster 1 (English UK, Spanish, French, Turkish, German, Russian)
Variant 2 P5: Variantcoding
Language-Cluster
2
Not used Language cluster 2 (Spanish, Portuguese, Greek, English UK, Not used)
Language cluster 2 (English UK, Spanish, French, Turkish, German, Russian)
Variant 3 P5: Variantcoding
Language-Cluster
3
Not used Language cluster 3 (Swedish, Norwegian, Finnish, Danish, English EU, Not used)
Language cluster 3 (English UK, Spanish, French, Turkish, German, Russian)
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 26 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Serial PCB Customer service PCB
Variant 4 P5: Variantcoding
Language-Cluster
4
Not used Language cluster 4 (Russian, Ukrainian, Polish, Turkish, English EU, German)
Language cluster 4 (English UK, Spanish, French, Turkish, German, Russian)
Variant 5 - 7 P5: Variantcoding
Language-Cluster
x
Not used
Setting language (range 0...7) Cluster 0
BO / SE / RE Cluster 0 Cluster 1 Cluster 2 Cluster 3 Cluster 4
Gaggenau Cluster 0 - 4
Variant 0 P5: Variantcoding
Language
0
German German Czech Spanish Swedish Russian English UK
Variant 1 P5: Variantcoding
Language
1
Italian Italian Hungarian Portuguese Norwegian Ukrainian Spanish
Variant 2 P5: Variantcoding
Language
2
French French English EU Greek Finnish Polish French
Variant 3 P5: Variantcoding
Language
3
Dutch Dutch German English Danish Czech UK
Turkish
Variant 4 P5: Variantcoding
Language
4
English EU English Slovenian Not used English English EU EU EU
German
Variant 5 P5: Variantcoding
Language
5
Turkish Turkish Not used Not used Not used German Russian
Variant 6 - 7 P5: Variantcoding
Language
x
Not used
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 27 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Serial PCB Customer service PCB
Setting brand (range 0...7)
Variant 0 P5: Variantcoding
Distribution
0
Gaggenau
Variant 1 P5: Variantcoding
Distribution
1
Siemens (SE) and Regional brands (RE)
Variant 2 P5: Variantcoding
Distribution
2
Bosch (BO)
Variant 3 - 7 P5: Variantcoding
Distribution
x
Not used
Setting key variant (range 0)
Variant 0 P5: Variantcoding
Operating Keys
0
Bosch (BO)
Variant 1 - 3 P5: Variantcoding
Operating Keys
x
Allowed, equal to variant 0
Variant 4 P5: Variantcoding
Operating Keys
4
Siemens und Regional brands (SE & RE)
><
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 28 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Serial PCB Customer service PCB
Variant 5 - 7 P5: Variantcoding
Operating Keys
x
Allowed, equal to variant 4
Setting menu variant (range 0)
Variant 0 P5: Variantcoding
Operating Menu
0
Not changeable Bosch, Siemens, Regional brands
Setting load display variant (range 0...1)
Variant 0 P5: Variantcoding
Load Display
0
With load display
Variant 1 P5: Variantcoding
Load Display
1
Without load display
Setting child lock variant (range 0...1)
Variant 0 P5: Variantcoding
Child Proof
0
Without child lock
Variant 1 P5: Variantcoding
Child Proof
1
With child lock
Setting valve terminal (range 0...1)
Variant 0 P5: Variantcoding
Valve Connector
0
Not changeable
Variant 1 P5: Variantcoding
Valve Connector
1
Not used
B/S/H/ Test Program / Coding Instruction PLC
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 5500 0000042668 ASP english Revision I
Page-No.
Test Program / Coding Instruction F20-A BLDC (ME156) Material-No.: 9000464025 29 of 29
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
1A06LM1A06LM1A06LM1A06LM1A06LM1A06LM Working Behnke
Function Actuation Display Remark Serial PCB Customer service PCB
Setting control variant (range 0...4)
Variant 0 P5: Variantcoding
Panel
0
Not used (P)
Variant 1 P5: Variantcoding
Panel
1
LC display (A)
Variant 2 P5: Variantcoding
Panel
2
Not used (E)
Variant 3 P5: Variantcoding
Panel
3
Not used (D)
Variant 4 P5: Variantcoding
Panel
4
Not used (S)